Mobius Model CCRF-5020-10-WW IEEE 802.11b Access Port Hardware Installation Guide Pre-Release 72-55582-01 May 20, 2002 Copyright Copyright 2002 by Symbol Technologies, Inc. All rights reserved. No part of this publication may be modified or adapted in any way, for any purposes without permission in writing from Symbol Technologies, Inc. (Symbol). The material in this manual is subject to change without notice. Symbol reserves the right to make changes to any product to improve reliability, function, or design. No license is granted, either expressly or by implication, estoppels, or otherwise under any Symbol Technologies, Inc., intellectual property rights. An implied license only exists for equipment, circuits and subsystems contained in Symbol products. Symbol, the Symbol logo and Spectrum24 are registered trademarks of Symbol Technologies, Inc. Patents This product is covered by one or more of the following U.S. and foreign Patents:
U.S. Patent No. 4,460,120; 4,496,831; 4,593,186; 4,603,262; 4,607,156; 4,652,750; 4,673,805; 4,736,095;
4,758,717; 4,816,660; 4,845,350; 4,896,026; 4,897,532; 4,923,281; 4,933,538; 4,992,717;
5,015,833; 5,017,765; 5,021,641; 5,029,183; 5,047,617; 5,103,461; 5,113,445; 5,130,520;
5,140,144; 5,142,550; 5,149,950; 5,157,687; 5,168,148; 5,168,149; 5,180,904; 5,216,232;
5,229,591; 5,230,088; 5,235,167; 5,243,655; 5,247,162; 5,250,791; 5,250,792; 5,260,553;
5,262,627; 5,262,628; 5,266,787; 5,278,398; 5,280,162; 5,280,163; 5,280,164; 5,280,498;
5,304,786; 5,304,788; 5,306,900; 5,321,246; 5,324,924; 5,337,361; 5,367,151; 5,373,148;
5,378,882; 5,396,053; 5,396,055; 5,399,846; 5,408,081; 5,410,139; 5,410,140; 5,412,198;
5,418,812; 5,420,411; 5,436,440; 5,444,231; 5,449,891; 5,449,893; 5,468,949; 5,471,042;
5,478,998; 5,479,000; 5,479,002; 5,479,441; 5,504,322; 5,519,577; 5,528,621; 5,532,469;
5,543,610; 5,545,889; 5,552,592; 5,557,093; 5,578,810; 5,581,070; 5,589,679; 5,589,680;
5,608,202; 5,612,531; 5,619,028; 5,627,359; 5,637,852; 5,664,229; 5,668,803; 5,675,139;
5,693,929; 5,698,835; 5,705,800; 5,714,746; 5,723,851; 5,734,152; 5,734,153; 5,742,043;
5,745,794; 5,754,587; 5,762,516; 5,763,863; 5,767,500; 5,789,728; 5,789,731; 5,808,287;
5,811,785; 5,811,787; 5,815,811; 5,821,519; 5,821,520; 5,823,812; 5,828,050; 5,850,078;
5,861,615; 5,874,720; 5,875,415; 5,900,617; 5,902,989; 5,907,146; 5,912,450; 5,914,478;
5,917,173; 5,920,059; 5,923,025; 5,929,420; 5,945,658; 5,945,659; 5,946,194; 5,959,285;
6,002,918; 6,021,947; 6,047,892; 6,050,491; 6,053,413; 6,056,200; 6,065,678; 6,067,297;
6,068,190; 6,082,621; 6,084,528; 6,088,482; 6,092,725; 6,101,483; 6,102,293; 6,104,620;
6,114,712; 6,115,678; 6,119,944; 6,123,265; 6,131,814; 6,138,180; 6,142,379; D305,885; D341,584;
D344,501; D359,483; D362,453; D363,700; D363,918; D370,478; D383,124; D391,250; D405,077;
D406,581; D414,171; D414,172; D418,500; D419,548; D423,468; D424,035; D430,158; D430,159;
D431,562 Invention No. 55,358; 62,539; 69,060; 69,187 (Taiwan); No. 1,601,796; 1,907,875; 1,955,269
(Japan);
European Patent 367,299; 414,281; 367,300; 367,298; UK 2,072,832; France 81/0938; Italy 1,138,713 Symbol Technologies, Inc. One Symbol Plaza Holtsville, N.Y. 11742-1300 Telephone: (800)SCAN234, (516) 738-2400 Telex: 6711519 http://www.symbol.com About this Document Audience This guide is intended for the technician responsible for installing the Mobius Wireless LAN Switch. It is also assumed that the technician is familiar with Ethernet LAN-based networking concepts. Purpose The purpose of this document is to provide specifications, features and guidelines for the installer to use during installation. This document does not give site-specific installation instructions. Refer to site-specific documentation, derived from site survey and site network analysis, for detailed installations. Document Conventions Before working on any equipment, be aware of the hazards associated with its installation and use. Also, become familiar with standard practices for preventing accidents. Note:
Indicates tips, hints and special requirements that the reader should take note. Caution!
Indicates that care is required. Disregarding cautions can result in data loss or equipment damage. WARNING!
Indicates a potentially dangerous condition or procedure that only Symbol-trained personnel should attempt to correct or perform. Warnings WARNING! Only trained and qualified personnel are allowed to install this equipment. WARNING! Read all installation instructions and site survey reports, and verify correct equipment installation before connecting the system to its power source. WARNING! Remove any jewelry (rings, watches, necklaces, etc.) while installing this equipment. WARNING! Verify that any device connected to this unit is properly wired and grounded. WARNING! Verify connecting power circuits have appropriate overload protection. WARNING! Attached only approved cables to this device. WARNING! Verify adequate ventilation around the device, and that ambient temperatures meet equipment operation specifications. WARNING! Verify uninterruptible power sources, if equipment is carrying emergency traffic. WARNING! Install unit in plenum-rated ceilings only. WARNING! Do not include the surface assembly for plenum-rated ceiling mounting. Introduction The Mobius Access Port provides area coverage to 802.11b wireless network devices. The Access Port includes different installing options, allowing best placement for the operate with its optimum range. The standard mounting base allows the unit to get secured to most surfaces by the use of two screws. The ceiling mounting option allows the unit to attach to ceiling by a single screw The Access Port receives power and transfers data through the same (CAT-5) cable. Technical Specifications Operating Voltage 48 vdc (typical) 36 vdc to 57 vdc (range) Operating Current 10 mA to 150 mA Peak Current Operating Temperature Operating Humidity Storage Temperature 250 mA
-20C to 50C 5% to 95%
-40 to 70C Altitude 2.4 km (operating max) 4.6 km (storage max) Mobius Model 5020 Access Port Hardware Installation Guide Jun/19/2002 Page 6 of 13 Drop MTBF
.8 meter (to concrete) 27,000 hrs Electrostatic Discharge
+/-15 kV (air discharge)
+/-8 kV (contact discharge)
+/-2 kV (pin discharge) Mobius Model 5020 Access Port Hardware Installation Guide Jun/19/2002 Page 7 of 13 Preparing for Site Installation Verify that the contents of the box include the following:
Access Port Assembly Surface-Mount Assembly Mounting Anchors Mounting Screws Surface-Mount Badge Surface-Mount Cover Surface-Mount Light Pipe Screw Ceiling-Mount Grommet Ceiling-Mount Badge Ceiling-Mount Light Pipe Screw Installation Guide Review Site survey and network analysis reports to determine the method for Access Port installation. Surface Mounting Mobius Access Ports mount to any surface, using the surface mounting screws. Use the mounting mask to determine the proper placement for the unit and the mounting screws. Mobius Model 5020 Access Port Hardware Installation Guide Jun/19/2002 Page 8 of 13 Mobius Model 5020 Access Port Hardware Installation Guide Jun/19/2002 Page 9 of 13 Ceiling Mounting Some installations require Access Port mounting above the ceiling tile. The type of installation hides the unit and cable away from visual access. Note: Use this installation in plenum-rated ceiling configurations. Verify that the attaching Ethernet cable is also plenum rated. Caution! Use care when pulling cables attached to a mounted unit. Mobius Model 5020 Access Port Hardware Installation Guide Jun/19/2002 Page 10 of 13 Power/Data (RJ-45) Connection The Access Port receives power from the Ethernet cable. It supports the following Symbol-branded Power-Over-Ethernet devices. Mobius 1-Port Power Port (Model ) Mobius 12-Port Power Port (Model ) Note: Review installation plans to determine device placement and cable routing. Mobius Model 5020 Access Port Hardware Installation Guide Jun/19/2002 Page 11 of 13 Customer Support Symbol Technologies provides its customers with prompt and accurate customer support. Use the Symbol Support Center as the primary contact for any technical problem, question or support issue involving Symbol products. If the Symbol Customer Support specialists cannot solve a problem, access to all technical disciplines within Symbol becomes available for further assistance and support. Symbol Customer Support responds to calls by email, telephone or fax within the time limits set forth in individual contractual agreements. When contacting Symbol Customer Support, please provide the following information:
serial number of unit
model number or product name
software type and version number. North American Contacts Inside North America, contact Symbol by:
Symbol Technologies, Inc. One Symbol Plaza Holtsville, New York 11742-1300 Telephone: 1-516-738-2400/1-800-SCAN 234 Fax: 1-516-738-5990 Symbol Support Center telephone: 1-800-653-5350 fax: (516) 563-5410 Email: support@symbol.com Mobius Model 5020 Access Port Hardware Installation Guide Jun/19/2002 Page 12 of 13 International Contacts Outside North America, contact Symbol by:
Symbol Technologies, Inc. Symbol Place Winnersh Triangle, Berkshire, RG41 5TP United Kingdom 0800-328-2424 (Inside UK)
+44 118 945 7529 (Outside UK) Symbol Developer Program Web Site http://software.symbol.com/devzone Symbol Knowledge Base http://kb.symbol.com/register.asp Additional Information Obtain additional information by contacting Symbol at:
1-800-722-6234, inside North America
+1-516-738-5200, in/outside North America
http://www.symbol.com/
Mobius Model 5020 Access Port Hardware Installation Guide Jun/19/2002 Page 13 of 13