all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
Users manual | Users Manual | 1.63 MiB | March 03 2016 | |||
1 |
|
Internal photographs | Internal Photos | 1.42 MiB | March 03 2016 | |||
1 |
|
External photographs | External Photos | 457.25 KiB | March 03 2016 | |||
1 |
|
Label / label location | ID Label/Location Info | 63.51 KiB | March 03 2016 | |||
1 |
|
Authorisation letter | Cover Letter(s) | 241.28 KiB | March 03 2016 | |||
1 |
|
Confidentiality request | Cover Letter(s) | 864.28 KiB | March 03 2016 | |||
1 | Test Report | March 03 2016 | ||||||
1 | Test Setup Photos | March 03 2016 |
1 | Users manual | Users Manual | 1.63 MiB | March 03 2016 |
SYMEO LOCAL POSITIONING RADAR Product: LPR-1D24 (Symeo BSV101757) Product Documentation Table of Content Copyright SYMEO GmbH 2009 Date: August 2009 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 1 of 34 SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting Content 1 GENERAL INFORMATION ........................................................................................ 6 1.1 Safety Instructions .................................................................................................... 6 1.2 Mounting .................................................................................................................... 6 1.3 Repairs....................................................................................................................... 6 1.4 Transport and Storage .............................................................................................. 6 1.5 Power Supply ............................................................................................................ 6 1.6 Setup and Operation ................................................................................................. 7 1.7 System Extensions and Accessories ...................................................................... 7 1.8 Additional Instructions ............................................................................................. 7 1.9 General Requirements for Compliance of Radio Apparatus .................................. 7 2 OVERVIEW OF LPR-1D24 UNIT .............................................................................. 8 2.1 Technical Data LPR-1D24 Unit ............................................................................... 9 3 MOUNTING AND ALIGNMENT OF LPR-1D24 UNITS ........................................... 10 3.1 Mounting of the Fall Protection .............................................................................. 11 4 5 REQUIREMENTS FOR POWER SUPPLY ............................................................... 12 SPECIFICATION OF THE CONNECTORS .............................................................. 13 5.1 Overview of Connections ....................................................................................... 13 5.2 Power Supply .......................................................................................................... 14 5.2.1 Plugs ......................................................................................................................... 14 5.2.2 Pin Assignment ......................................................................................................... 14 5.3 Ethernet M12 ........................................................................................................... 14 5.3.1 Plugs ......................................................................................................................... 15 5.3.2 Pin Assignment ......................................................................................................... 15 5.3.3 Connector Cable M12 RJ45 ................................................................................... 15 USB mini ............................................................................................................... 15 5.4 5.4.1 Plugs ......................................................................................................................... 16 5.5 USB A Devices ..................................................................................................... 16 Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 2 of 34 General Information SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting 6 7 LPR-1D24 HOUSING DIMENSIONS ...................................................................... 17 WEB USER INTERFACE FOR LPR-1D24 .............................................................. 18 7.1 Requirements .......................................................................................................... 18 7.1.1 Connection to LPR-1D24 Unit ................................................................................. 18 7.2 Open User Interface ................................................................................................ 20 7.3 Device ...................................................................................................................... 22 7.4 Device - Device Configuration ............................................................................... 23 7.4.1 Device - Device Configuration LAN ........................................................................ 24 7.4.2 Device - Device Configuration System Time .......................................................... 26 7.5 Device - Application Settings ................................................................................. 26 7.5.1 Device - Application Settings Customer Protocol ................................................... 27 7.5.2 Device - Application Settings General .................................................................... 27 7.6 Diagnostics ............................................................................................................. 30 7.6.1 Diagnostics - Operating System Status ..................................................................... 31 7.6.2 Diagnostics - Hardware Status .................................................................................. 32 7.6.3 Diagnostics - Distance over Time .............................................................................. 33 7.6.4 Diagnostics - Signal Strength over Distance Diagram ............................................... 34 Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 3 of 34 General Information SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting Table of Figures Figure 1: LPR-1D24 measurement path .............................................................................. 8 Figure 2: LPR-1D24 unit inclusive mounting bracket ...........................................................10 Figure 3: Mounting of the fall protection ................................................................................11 Figure 4: LPR-1D24 Connectors .........................................................................................13 Figure 5: M12 Connector for the power requirement ............................................................14 Figure 6: M12 Ethernet M12 .................................................................................................15 Figure 7: LPR-1D24 Housing Dimensions ..........................................................................17 Figure 8: Network Settings ...................................................................................................19 Figure 9: Ping LPR-1D24 unit .............................................................................................19 Figure 10: Homepage of the LPR-1D24 unit .......................................................................20 Figure 11: Sign in on the home page of the LPR-1D24 unit ................................................21 Figure 12: Device Menu .......................................................................................................22 Figure 13: Information overview and device status ...............................................................22 Figure 14 Device: Device Configuration Menu ...................................................................23 Figure 15 Device: Device Configuration - LAN Settings .....................................................24 Figure 16 Device: Device Configuration LAN Settings - Commit the change .....................25 Figure 17 Device: Device Configuration LAN Settings - Changes have been applied ........25 Figure 18 Device: Device Configuration - SystemTime Settings ........................................26 Figure 19 Device: Application Settings ..............................................................................27 Figure 20 Device: Application Settings - Costumer Protocol Settings ................................27 Figure 21 Device: Application Settings General Settings ................................................28 Figure 22: Example configuration of one measurement pair Master and Slave Unit .............29 Figure 23 Diagnostics Menu ..............................................................................................30 Figure 24 Diagnostics: Operating System Status ...............................................................31 Figure 25 Diagnostics: Hardware Status............................................................................32 Figure 26 Diagnostics: Distance over time .........................................................................33 Figure 27 Diagnostics: Signal strength over distance diagram ...........................................34 Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 4 of 34 General Information SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting The documentation for the LPR-1D24 Local Positioning Radar System is published by:
SYMEO GmbH Prof.-Messerschmitt-Str. 3 D-85579 Neubiberg www.symeo.de If you have any questions or suggestions, please contact:
Email: info@symeo.com phone: +49 89 660 7796 0 Copyright Symeo GmbH 2010 All rights reserved HISTORY Version Date Description 1.00 29.01.2016 Initial Release SYMBOLS USED The following symbols are used throughout the documentation:
This symbol appears before instructions that must be followed at all times. Failure to comply with these instructions will result in personal injury. This symbol appears before instructions that must be followed at all times. Failure to comply with these instructions will result in damage to equipment. This symbol appears before information of particular importance. All rights reserved, particularly those relating to the translation, reprinting, and reproduction by photocopying or similar processes of all or part of the documentation. All rights reserved, particularly for purposes of the award of patents or submission of utility models. Delivery options and technical changes reserved. Published by SYMEO GmbH Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 5 of 34 General Information SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting 1 General Information 1.1 Safety Instructions LPR-1D24 Systems are purely tracking and assistance systems. They therefore do not satisfy special requirements for personal safety. Follow the safety instructions in this documentation!
1.2 Mounting All mounting, installation and maintenance work must be carried out by an electrically qualified or trained person!
1.3 Repairs Repairs on the devices should only be performed by Symeo GmbH. 1.4 Transport and Storage Use the original packaging or other suitable packaging for returns and whenever the system is to be transported. This ensures protection from crushing, impact, moisture and electrostatic discharge. During setup and before operation, refer to the instructions for environmental conditions in this document and in the data sheet. Place the cables in such a way so that they do not build the possible cause of risk and are not damaged. 1.5 Power Supply While installing or using it in open-air, the transient overvoltage cannot be excluded. Here, overvoltage protection is to be used for low voltage in accordance to DIN EN 61643-21 and IEC 61643-21. While connecting the plug and sockets, please observe the correspondent chapter in this document "Specification of Connectors". Do not use damaged cables (damaged insulation, bare wires). A defective cable may cause a fire hazard. Be careful that the device can be damaged with reverse polarity despite of strict implementation of polarity reversal protection. In that case the unit must be sent to the SYMEO service for further testing. Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 6 of 34 General Information 1.6 Setup and Operation SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting During mounting, make sure that no objects or liquids reach inside the device (risk of short-circuit). In case of emergency (e.g. damaged housing, control elements or power cables, penetration of liquids or foreign bodies) switch off the device immediately, disconnect from the power line the device and inform your SYMEO service. Protect the contacts of all sockets and plugs of the device from static electricity. Avoid touching the contacts. If touching the contacts is unavoidable, then one should take the following precautions: Touch a grounded object or wear a ground strap before touching the contacts. This will dissipate static charges. The device must be secured against falling. The LPR-1D24 unit must not be opened. 1.7 System Extensions and Accessories Data cables to peripheral devices must be shielded properly. For LAN cabling, the requirements apply in accordance with EN 50173 and EN 50174-1/2. Use of either a Category 5 shielded cable for 10/100 Ethernet or Category 5e shielded cable for Gigabit Ethernet is a minimum requirement. The specifications of standard ISO/IEC 11801 must be complied with. The warranty becomes void in case of any damages caused by replacement of components on the device during installation. 1.8 Additional Instructions Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. 1.9 General Requirements for Compliance of Radio Apparatus This device complies with Part 15 of the FCC Rules and with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 7 of 34 General Information SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting 2 Overview of LPR-1D24 Unit LPR-1D24 is a highly precise radio sensor for distance measurement. Two paired units allow for long range applications and enable additional data transfer at the same time. The exact position of a moving machine component, e.g. a crane or crane trolley, can thus be dynamically determined in real-time, while data collected at one end (e.g. a load cell input) is available at the paired unit simultaneously. Figure 1: LPR-1D24 measurement path In addition to the distance reading, the relative approach speed of the LPR sensors is available. Distance and speed can be used for internal collision avoidance decisions at predetermined distance thresholds. Optional on-board relays will be activated. All data is made available at standard interfaces. The devices are easy to install and operate. Rough alignment between the facing units is sufficient, even for very long distances. The multi-channel radio antenna is integrated into the robust housing. A built-in terminal server allows straightforward configuration of the unit ID, the paired unit ID and other parameters in any browser. Symeo LPR radio works highly reliable under adverse conditions. Interference with any WiFi equipment operating in parallel can be excluded at all times. A unique ID per each unit allows operating multiple pairs in immediate vicinity. LPR-1D24 sensors are maintenance-free and paired sensors can be interconnected with other pairs, providing several distances at a single interface, e.g. for crane xy position acquired by two sensor pairs. Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 8 of 34 Overview of LPR-1D24 Unit Distance measurement and user data transmissionLPR-1D24 SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting 2.1 Technical Data LPR-1D24 Unit The technical specifications for LPR-1D24 can be found in our data-sheet under the following link:
http://www.symeo.com/cms/upload/pdf/en/DataSheets/Symeo_Datasheet_LPR-1D24.pdf Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 9 of 34 Overview of LPR-1D24 Unit SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting 3 Mounting and Alignment of LPR-1D24 Units The device must be secured against falling. All mounting, installation and maintenance work must be carried out by electrician or a person with similar training and skills!
The LPR-1D24 units are delivered with a separate mounting bracket (see Figure 2). Figure 2 shows a complete system including the mounting bracket. The bracket must be mounted with a pipe clamp on a pipe. The pipe diameter is best chosen between 40 mm and 75 mm. For mounting, a flat wrench of SW 13 is required. For mounting the system, please proceed as follows:
At a suitable place, mount the LPR-1D24 unit to a suitable pipe with the bracket. To adjust the system, do not tighten the mounting bracket finally. Specified alignments have to be adhered to if indicated by Symeo. A minimum distance of 3 meters between the measuring system units must be maintained to guarantee the specified accuracy. Mounting closer than the minimum distance decreases the accuracy at close proximity. The units must have the same orientation for mounting, for example both units with connectors downwards. For outdoor use the units have to be mounted with the connectors downwards. Now adjust the system on the opposite side. The two system units should be mounted opposite to each other and possibly should not be an offset horizontal and vertical from each other or twisted. Now fix the system by tightening the screws in the mounting bracket and the mounting bracket on pipe in such a way that no modification is possible anymore. Flat wrench SW 13 is required. Figure 2: LPR-1D24 unit inclusive mounting bracket Mounting and Alignment of LPR-1D24 Units Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 10 of 34 SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting 3.1 Mounting of the Fall Protection The LPR-1D24 units must be protected against fall. For every unit Symeo provides a protection set consisting of the following components:
A: 2 x ring nuts M5, B: 2 x snap hooks 5 x 50 mm C: 1 x steel cable 3 mm x 1 m The two ring nuts must be mounted on the back of the LPR-1D24 unit laterally on the respective second screw from above, which are 4 mm longer than the other screws. Then the snap hook must be attached to the ring nuts. Please put the steel cable around a pipe or a bracket and hang it also in the snap hook (see picture below). The backup set should be installed before the assembly of the unit to secure it against falling. Figure 3: Mounting of the fall protection Mounting and Alignment of LPR-1D24 Units Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 11 of 34 CAB SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting 4 Requirements for Power Supply The power supply should have the following characteristics:
Potential free Output power at least 25 W Output voltage 10 V DC to 36 V DC Short-term maximum current flow (when switched on):
o o At 24 V DC: 2000 mA for 50 ms At 12 V DC: 2500 mA for 50 ms Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 12 of 34 Requirements for Power Supply SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting 5 Specification of the Connectors 5.1 Overview of Connections All connectors are fixed externally to the housing. Figure 4 shows the connections in detail. Figure 4: LPR-1D24 Connectors B1: Ethernet B2: Can-Bus IN/ Profibus IN B3: Can-Bus OUT/ Profibus OUT/ Termination (optional) B4: Pressure equalization membrane B5: Serial interface RS422/RS485 / Relays (optional) B6: Power supply B7: Mini-USB B8: USB A (Logging) B9 B11: Status LEDs On the following pages you will find the connector type, the pin assignment, the product code and the Symeo order number. For more information, please see the data sheets on the attached data carrier. Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 13 of 34 Specification of the Connectors B1B2B5B7B6B4B3B9B1B2B5B7B6B4B3B11B10B9B8 SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting 5.2 Power Supply The LPR-1D24 unit is powered by a 4-pin M12-Connector to the operating voltage (Figure 4 Connection B6). 5.2.1 Plugs Recommended connector:
o SACC-M12FST-4PECON-PG 9-M 1418052 Cable diameter: 6 - 8 mm Symeo order number: MTE101761 Figure 5: M12 Connector for the power requirement 5.2.2 Pin Assignment Power Supply 10 V DC 36 V DC M12 Connector VDC+
VDC+
VDC-
VDC-
Table 1: Pin assignment power supply 5.3 Ethernet M12 Pin 1 Pin 2 Pin 3 Pin 4 The LPR-1D24 unit can be connected to the Ethernet via M12-Connector (Figure 4 Connection B1). Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 14 of 34 Specification of the Connectors SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting 5.3.1 Plugs Recommended connector:
Connector Ethernet M12 o SACC-M12MSD-4CON-PG 7-SH 1521258 Cable diameter: 4 6 mm (PG7) Symeo order number: MTE101768 Figure 6: M12 Ethernet M12 5.3.2 Pin Assignment Signal Color of Conductor Color of Conductor Pin Assignment PROFInet EIA/TIA 568B TD+
TD-
RD+
RD-
Yellow Orange White Blue White/Orange Orange White/Green Green 1 3 2 4 Table 6: Pin assignment for Ethernet M12 5.3.3 Connector Cable M12 RJ45 The connector cable M12 RJ45 is required for the Ethernet-connection for configuration of the LPR -1D24 units with M12 plug and RJ 45 connector. o Symeo order number: MTE102007 5.4 USB mini The LPR-1D24 units are equipped with a USB mini connector externally (Figure 4 Connector B7). This port is only for service use. Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 15 of 34 Specification of the Connectors SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting 5.4.1 Plugs Recommended connector:
Connector: SCPU-10-G-02.00-MBS-AM from Samtec USB mini-B-plug Pin assignment according to USB-Standard If the USB-port at the device is not used, it must be closed with the end cap to prevent leakage. 5.5 USB A Devices The LPR-1D24 unit has a USB-Flash Drive Connector, on which the data can be logged for service purposes (Figure 4 Connection B8). Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 16 of 34 Specification of the Connectors 6 LPR-1D24 Housing Dimensions SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting Figure 7: LPR-1D24 Housing Dimensions The minimum pipe diameter is 40 mm, the maximum pipe diameter is 75 mm. Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 17 of 34 LPR-1D24 Housing Dimensions SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting 7 Web User Interface for LPR-1D24 This chapter describes the LPR-1D24 Web User Interface. Connection via the Ethernet is required!
For the Ethernet-connection the connector cable M12 RJ45 is required for configuration of the LPR -1D24 units with M12 plug and RJ 45 connector. This connector cable can be ordered by Symeo (see 5.3.3). 7.1 Requirements In order for a unit to be successfully commissioned, the LPR-1D24 components must have been installed correctly:
The unit has been connected to the power supply. Data link has been established over TCP/IP. Once these prerequisites have been fulfilled, you can connect the unit to the network and commission the LPR-1D24 system. How to do this is explained in the following chapters. 7.1.1 Connection to LPR-1D24 Unit At delivery the IP-address of the LPR-1D24 unit is set to 192.168.1.99, if no other IP-Address is labeled outside the LPR-1D24 unit. You can change the IP-Address of the LPR-1D24 unit via the web interface of the LPR-Unit. To get a connection between your PC and the LPR-1D24 unit it is maybe necessary to change the network parameters of your computer. The PC and the LPR-1D24 unit must be located in the same network. That means in this example that the first three numeric pads of both IP-addresses must be the same. Disconnect your PC from the network. Connect the LPR-1D24 unit and the computer with a network cable. Open the network settings of your computer (see picture below). Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 18 of 34 Web User Interface for LPR-1D24 Figure 8: Network Settings SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting Enter the following fixed IP-address i.e. 192.168.1.1. The subnet mask should be set to 255.255.255.0. Click in both windows OK. If the firewall settings are too restrictive, you may not get access to the LPR-1D24 unit. In this case deactivate the firewall temporarily. The LPR unit should be available via your PC now. You can check the connection with a ping to the LPR-1D24 unit:
Open the Command-Window:
1. Push the Windows Start Button 2. Choose Run 3. Enter cmd and click OK 4. Enter in the cmd.exe window: ping 192.168.1.99 or the IP-address of the LPR-1D24 unit. Figure 9: Ping LPR-1D24 unit The LPR-1D24 unit should answer with a Reply. Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 19 of 34 Web User Interface for LPR-1D24 SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting 7.2 Open User Interface At delivery, the IP-address of the LPR-1D24 unit is 192.168.1.99, unless another IP-address is labeled outside the box. Open your web browser. In the address bar of the web browser enter the IP-address of the LPR-1D24 unit: http://192.168.1.99. Press Enter. A connection is established with your LPR-1D24 unit. Figure 10: Homepage of the LPR-1D24 unit The homepage of the LPR-1D24 unit's Web User Interface will appear. A website language selection can be made using the flags in the top right corner of the homepage. Click the "Sign in" button in the top right corner of the homepage. The dialog box with the username and password field will appear (see picture below). Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 20 of 34 Web User Interface for LPR-1D24 SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting Enter the user name "symeo" and the password "54all2u" and press "Login". Now your status is displayed as "Logged in". Figure 11: Sign in on the home page of the LPR-1D24 unit You can always come back to this page if you press on the Symeo symbol or the Symeo character in the top left hand corner of this page. Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 21 of 34 Web User Interface for LPR-1D24 SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting 7.3 Device With this function (see picture below) you switch either to:
Device configuration Application settings VPN remote access settings Firmware update Reboot device Furthermore you will find on top of every page the device status (see picture below):
Figure 12: Device Menu The information overview shows you the Hostname of the LPR-1D24 unit and its IP-
Figure 13: Information overview and device status address. The device status shows you the status of the services and interfaces. o The service status Measurement Filter and Measurement Daemon and also the interface status Binary protocol must be green, otherwise please contact Symeo customer support. It takes some seconds after switching on or after a reboot before the color changes to green. A yellow color could indicate as well an error in the configuration settings. The interface status Binary protocol is only green if the customer is connected to the binary port. Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 22 of 34 Web User Interface for LPR-1D24 SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting 7.4 Device - Device Configuration With this function (see picture below) you can chose either to:
define the LAN settings define Modem settings define the Profibus settings define the Remote Access settings set the System Time set WLAN settings Figure 14 Device: Device Configuration Menu Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 23 of 34 Web User Interface for LPR-1D24 SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting 7.4.1 Device - Device Configuration LAN With this function (see picture below) you can:
chose the Link type define the Address Mode change the IP-Address change the IP-Netmask change the Gateway change the local Hostname change the DNS IP-Address change the IP-Address of a Syslog Server change the Network routes Figure 15 Device: Device Configuration - LAN Settings Please press Enter or Save Settings after you did changes. Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 24 of 34 Web User Interface for LPR-1D24 SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting Following message appears in the upper left corner Saved successfully (see picture below). Furthermore it will be shown in green, what has been saved (in the picture below the hostname). Now you need to press Commit if you want to apply the change. The unit will perform a reboot to apply it. If you want to discard the change, press Reset. Figure 16 Device: Device Configuration LAN Settings - Commit the change If the changes are applied successfully, it will be indicated in the upper left corner of the web page. Figure 17 Device: Device Configuration LAN Settings - Changes have been applied All changes always have to be saved and confirmed. Only then the changes are applied on the unit. Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 25 of 34 Web User Interface for LPR-1D24 SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting 7.4.2 Device - Device Configuration System Time With this function (see picture below) you chose to set the time zone o must be set to custom timezone if needed timezone is not in the dropdown menu set the IP-address of the NTP-server set the Custom timezone o needs to be filled if custom timezone is used Figure 18 Device: Device Configuration - SystemTime Settings 7.5 Device - Application Settings With this function (see picture below) you switch either to:
Customer protocol General (configuration parameter) Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 26 of 34 Web User Interface for LPR-1D24 SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting Figure 19 Device: Application Settings 7.5.1 Device - Application Settings Customer Protocol With this function (see picture below) you chose to:
set the Protocol frame length set the Protocol TCP port define the Output interval of customer protocol Figure 20 Device: Application Settings - Costumer Protocol Settings 7.5.2 Device - Application Settings General With this function (see picture below) you can set the LPR-1D24 settings:
LPR group ID o Group identifier of one pair of LPR units, associated together. Has to be the same on units measuring with each other. Diverse measurement paths must also be adjusted to different group IDs. Web User Interface for LPR-1D24 Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 27 of 34 SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting Measurement mode o Measuring mode for the LPR-1D24 unit. Any measuring pair of LPR-1D24 units has to consist of one Master and one Slave Unit. FSK communication channel o Data communication channel number. Has to be the same on all units needing to communicate with each other. o The lowest usable communication channel is channel 16, the highest usable channel is channel 95, depending on the configuration of the device. A set of 20, 40 or 80 usable channels can be configured. Measurement channel o Changes ramp slope of measurements. Has to be configured identically on Master and Slave Unit of one pair. Can be changed to separate interfering pairs when other pairs are close by. Figure 21 Device: Application Settings General Settings Example Configuration of one pair of LPR units:
Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 28 of 34 Web User Interface for LPR-1D24 SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting Figure 22: Example configuration of one measurement pair Master and Slave Unit Configuration rules:
Dont use a group ID more than once per site. If pairs of LPR-units are mounted close to each other, the FSK channels should be at least two channels apart from each other. The bandwidth variation number should stay on the default value 0. Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 29 of 34 Web User Interface for LPR-1D24 SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting 7.6 Diagnostics With this function (see picture below) you chose to:
Operating System Status Hardware Status Record measurement data Distance over time diagram Signal strength over distance diagram Figure 23 Diagnostics Menu Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 30 of 34 Web User Interface for LPR-1D24 SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting 7.6.1 Diagnostics - Operating System Status With this function (see picture below) the operating system status can be seen. In case of problems, these information may be asked by Symeo support. Figure 24 Diagnostics: Operating System Status Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 31 of 34 Web User Interface for LPR-1D24 SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting 7.6.2 Diagnostics - Hardware Status With this function (see picture below) system values and system voltages are displayed. In case of problems, these information may be asked by Symeo support. Figure 25 Diagnostics: Hardware Status This display is automatically refreshed every 5 seconds. Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 32 of 34 Web User Interface for LPR-1D24 SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting 7.6.3 Diagnostics - Distance over Time With this function (see picture below) the current distance and the current RSSI value (Signal strength) will be displayed. Furthermore the distance over time graph. Figure 26 Diagnostics: Distance over time By pointing the mouse in the graph and using the scroll wheel you can downsize or enlarge the timeline. Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 33 of 34 Web User Interface for LPR-1D24 7.6.4 Diagnostics - Signal Strength over Distance Diagram SYMEO Local Positioning Radar System LPR-1D24 LPR-1D24 Station Overview and Mounting Figure 27 Diagnostics: Signal strength over distance diagram This diagram shows the recorded distance-signal strength pairs since the last power-on. You can use it to detect abnormal signal propagation routes at certain constellations of the two LPR-1D24 stations, as the signal strength should decrease with increasing distance. The diagram is automatically refreshed every 10 seconds. The distance axis displays the distance between the two LPR-1D24 stations, and the RSSI axis the received signal strength in dB. As the signal strength at specific distances may vary, the statistical distribution of the signal strength is also recorded. Displayed are the mean received signal strength, the 10 % quantile and the 90 % quantile. The Quantiles give you information about how many recorded signal strength values were lower than the corresponding line. 10 % of the recorded signal strengths were lower than the 10 % quantile line and 90 % were lower than the 90 % quantile line, leaving 80 % in between those two lines. This way you get an idea of the signal strength distribution per distance without including extreme outliers. This helps identifying distances with increased signal distortions
(e.g. due to multipath signal propagation), as the variance of the signal strength there usually increases. Copyright SYMEO GmbH 2015 LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx Page 34 of 34 Web User Interface for LPR-1D24
1 | Label / label location | ID Label/Location Info | 63.51 KiB | March 03 2016 |
Examples of BSV101757 Labels Additional Label for RSS-310 (IC Canada):
70mm 60mm m m 6 3 m m 6 3 70mm Symeo 1D24 (BSV101757): Label position
1 | Authorisation letter | Cover Letter(s) | 241.28 KiB | March 03 2016 |
Authority to Act as Agent Date: 2016/01/27 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 To Whom It May Concern:
We the undersigned, hereby authorize CSA Group Bayern GmbH, Ms. Bettina Stangl, Ohmstrasse 1-4, 94342 Strasskirchen, Germany to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by CSA Group Bayern GmbH on our behalf shall have the same affect as acts of our own. This authorization is valid until fi tther written notice from SYMEO GmbH.
By: [i' G; / Andreas Bernhard
(Signatupe) (Print name) Title: Developer On behalf of: SYMEO GmbH
(Company Name) Telephone: 089/6607796320
'. Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.
1 | Confidentiality request | Cover Letter(s) | 864.28 KiB | March 03 2016 |
THIS MUST BE SIGNED BY THE APPLICANT/AGENT AND SHOULD BE PLACED ON APPROPRIATE LETTERHEAD Request_for Confidentiality Date: 2016/01/28 Subject: Confidentiality Request for FCC ID: W5IBSV101757 / IC ID: 8185A- BSV101757 Pursuant to FCC 47 CRF 0.457(d) and 0.459 and IC RSP-100, Section 6.4, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit _] Short Term [Xx] Permanent Block Diagrams
>X] Short Term External Photos Short Term [] Permanent*! Internal Photos
[] Short Term Permanent Operation Description/Theory of Operation
[_] Short Term IX] Permanent Parts List & Placement/BOM
[_] Short Term [_] Permanent Tune-Up Procedure
[_] Short Term XX] Permanent Schematics Short Term Test Setup Photos
[_] Short Term [_] Permanent* Users Manual
*Note: (Insert Explanation as Necessary) Symeo GmbH has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality:
The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality:
The applicant requests the exhibits selected above as short term confidential be withheld from public view for a periodof _( 180) days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify ACB in the event information regarding the product or the product is made available to the public. ACB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. NOTE for Industry Canada Applications:
The applicant understands that until such time that IC distinguishes between Short Term and Permanent Confidentiality, either type of marked exhibit above will simply be marked Confidential when submitted to IC. Sincerely, Andreas Bernhard
(Print name) By:
| _ The asterisked items (*) require further justification before permanent confidentiality will be allowed. These also currently require review by the FCC under their Permit-But-Ask policy before the grant is issued and can delay completion of an application. Further justification should be added to the note above. One such example for a potted device would be: The EUT is FULLY potted using a non-removable epoxy based material. Removal of potting material causes irreparable damage to internal circuitry. See photographs exhibits that outline the device before and after potting. 2 _ Please refer to http://acbcert.com/documents/misc-docs/Memo-Short-Term-Vs-Standard-Confidentiality.pdf for complete details. 3 _ Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead.
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2016-03-03 | 24037 ~ 24241 | DXX - Part 15 Low Power Communication Device Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2016-03-03
|
||||
1 | Applicant's complete, legal business name |
Symeo GmbH
|
||||
1 | FCC Registration Number (FRN) |
0018504928
|
||||
1 | Physical Address |
Professor-Messerschmitt-Str. 3
|
||||
1 |
Neubiberg, 85579
|
|||||
1 |
Germany
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
h******@acbcert.com
|
||||
1 | TCB Scope |
A2: Low Power Transmitters (except Spread Spectrum) and radar detectors operating above 1 GHz
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
W5I
|
||||
1 | Equipment Product Code |
BSV101757
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
A******** B******
|
||||
1 | Telephone Number |
+49 8******** Extension:
|
||||
1 | Fax Number |
+49 8********
|
||||
1 |
a******@symeo.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
CSA Group Bayern GmbH
|
||||
1 | Name |
H**** S******
|
||||
1 | Physical Address |
Ohmstr. 1-4
|
||||
1 |
Strasskirchen, 94342
|
|||||
1 |
Germany
|
|||||
1 | Telephone Number |
+4994******** Extension:
|
||||
1 |
H******@csagroup.org
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 08/30/2016 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Positioning Radar 24 GHz | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
CSA Group Bayern GmbH
|
||||
1 | Name |
T******** W******
|
||||
1 | Telephone Number |
49-94********
|
||||
1 | Fax Number |
49-94********
|
||||
1 |
t******@csagroup.org
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 24016 | 24095 | |||||||||||||||||||||||||||||||||||||
1 | 2 | 15C | 24037 | 24241 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC