WARNING:pdfminer.pdfpage:The PDF <_io.BufferedReader name='/Volumes/Scratch/Incoming/eg-scratch/5487470.pdf'> contains a metadata field indicating that it should not allow text extraction. Ignoring this field and proceeding. Use the check_extractable if you want to raise an error in this case SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.0 Report No.: GZCR210802082502 Page: 1 of 8 FCC ID: 2ANDR-BTC0121 RF EXPOSURE EVALUATION REPORT Application No.:
Applicant:
Address of Applicant:
Manufacturer:
Address of Manufacturer:
GZCR2108020825AT SZ DJI Osmo Technology Co., Ltd. 4F, Jingkou Community Comprehensive Service Building, No. 83 Bishui Road North, Guangming Street, Guangming District, Shenzhen SZ DJI Osmo Technology Co., Ltd. 4F, Jingkou Community Comprehensive Service Building, No. 83 Bishui Road North, Guangming Street, Guangming District, Shenzhen Equipment Under Test (EUT):
EUT Name:
Model No.:
Trade Mark:
Standard(s) :
DJI Remote Control Pad BTC01 DJI 47 CFR PART 1, Subpart I, Section 1.1310 47 CFR PART 2, Subpart J, Section 2.1093 KDB447498D01 General RF Exposure Guidance v06 Date of Receipt:
2021-08-19 Date of Evaluation:
2021-08-22 to 2021-08-25 Date of Issue:
Evaluation Result:
2021-08-26 Pass*
* In the configuration evaluated, the EUT complied with the standards specified above. Kobe Jian EMC Laboratory Manager SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.0 Report No.: GZCR210802082502 Page: 2 of 8 Revision Record Version Chapter Date Modifier Remark 01 2021-08-26 Original Authorized for issue by:
Tested By Reviewed By Kevin Zhang/Project Engineer Ricky Liu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.0 Report No.: GZCR210802082502 Page: 3 of 8 2 Evaluation Summary Note:
E.U.T./EUT means Equipment Under Test. Pass means the test result passed the test standard requirement, please find the detailed decision rule in the report relative section. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZCR210802082502 Page: 4 of 8 EMC-TRF-03 Rev 1.0 3 Contents Page 1 Cover Page ......................................................................................................................................... 1 2 3 4 Evaluation Summary .......................................................................................................................... 3 Contents ............................................................................................................................................. 4 General Information............................................................................................................................ 5 4.1 4.2 4.3 4.4 4.5 Details of E.U.T. .......................................................................................................................... 5 Evaluating Location ...................................................................................................................... 5 Facility ......................................................................................................................................... 6 Deviation from Standards ............................................................................................................. 6 Abnormalities from Standard Conditions ....................................................................................... 6 5 Technical Requirements Specification .............................................................................................. 7 5.1 RF Exposure Evaluation ............................................................................................................... 7 5.1.1 Limit & Test Method ................................................................................................................. 7 5.1.2 Conclusion ............................................................................................................................... 7 6 EUT Constructional Details (EUT Photos) ......................................................................................... 8 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.0 Report No.: GZCR210802082502 Page: 5 of 8 DC 3.7V Lithium-ion 65mAh rechargeable battery (to be charged from Type C port) 2402MHz to 2480MHz 4 General Information 4.1 Details of E.U.T. Power supply:
Operation Frequency:
Bluetooth Version:
Modulation Type:
Number of Channels:
Data Rate:
Channel Spacing:
Antenna Type:
Antenna Gain:
V5.0 LE GFSK 40 1Mbps, 2Mbps 2MHz Dipole Antenna 3dBi 4.2 Evaluating Location All tests were performed at:
SGS-CSTC Standards Technical Services Co., Ltd., Guangzhou Branch EMC Laboratory, 198 Kezhu Road, Scientech Park, Guangzhou Economic & Technology Development District, Guangzhou, China 510663 Tel: +86 20 82155555 No tests were sub-contracted. Fax: +86 20 82075059 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Report No.: GZCR210802082502 Page: 6 of 8 EMC-TRF-03 Rev 1.0 4.3 Facility The facility is recognized, certified, or accredited by the following organizations:
NVLAP (Lab Code: 200611-0) SGS-CSTC Standards Technical Services Co., Ltd., Guangzhou EMC Laboratory is accredited by the National Voluntary Laboratory Accreditation Program (NVLAP/NIST). NVLAP Code: 200611-0. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. ACMA SGS-CSTC Standards Technical Services Co., Ltd., EMC Laboratory can also perform testing for the Australian/New Zealand Regulatory Compliance Mark (RCM). SGS UK(Certificate No.: 32), SGS-TUV SAARLAND and SGS-FIMKO Have approved SGS-CSTC Standards Technical Services Co., Ltd., EMC Laboratory as a supplier of EMC TESTING SERVICES and SAFETY TESTING SERVICES. CNAS (Lab Code: L0167) SGS-CSTC Standards Technical Services Co., Ltd., EMC Laboratory has been assessed and in compliance with CNAS-CL01:2018 accreditation criteria for testing laboratories (identical to ISO/IEC 17025:2017 General Requirements) for the Competence of Testing Laboratories. FCC Recognized Accredited Test Firm(Registration No.: 486818) SGS-CSTC Standards Technical Services Co., Ltd., EMC Laboratory has been accredited and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. Designation Number: CN5016, Test Firm Registration Number: 486818. ISED (Registration No.: 4620B, CAB identifier: CN0052) SGS-CSTC Standards Technical Services Co., Ltd., has been registered by Innovation Science and Economic Development Canada for Wireless Device Testing laboratories to test to Canadian radio equipment requirements. Registration No. 4620B, CAB identifier: CN0052. VCCI (Registration No.: R-12460, C-12584, G-20107 and T-11179) The 10m Semi-anechoic chamber, 966 Anechoic Chamber and Shielded Room of SGS-CSTC Standards Technical Services Co., Ltd. have been registered in accordance with the Regulations for Voluntary Control Measures with Registration No.: R-12460, C-12584, G-20107 and T-11179 respectively. CBTL (Lab Code: TL129) SGS-CSTC Standards Technical Services Co., Ltd., E&E Laboratory has been assessed and fully comply with the requirements of ISO/IEC 17025:2017, the Basic Rules, IECEE 01 and Rules of procedure IECEE 02, and the relevant IECEE CB-Scheme Operational documents. 4.4 Deviation from Standards None 4.5 Abnormalities from Standard Conditions None SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.0 Report No.: GZCR210802082502 Page: 7 of 8 5 Technical Requirements Specification 5.1 RF Exposure Evaluation 5.1.1 Limit & Test Method The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]
[f(GHz)] 3.0 for 1-g SAR and 7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation17 The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is
< 5 mm, a distance of 5 mm is applied to determine SAR test exclusion 5.1.2 Conclusion dBm on the lowest channel 2.402 GHz The Max Conducted Peak Output Power is 2.5 2.5 dBm logarithmic terms convert to numeric result is nearly 1.78 mW According to the formula. calculate the test exclusion thresholds:
[(max. power of channel, including tune-up tolerance, mW)/
(min. test separation distance, mm)] [f(GHz)]
General RF Exposure = (1.78 mW / 5 mm) x 2.402 GHz = 0.55 SAR requirement:
S = 3.0
(1) < (2) So the SAR report is not required.
(1)
(2) Note: Refer to report No. GZCR210802082501 for EUT test Max Conducted Peak Output Power value. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.0 Report No.: GZCR210802082502 Page: 8 of 8 6 EUT Constructional Details (EUT Photos) Refer to external and internal photos for GZCR2108020825AT