all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 1.89 MiB | December 08 2022 / June 07 2023 | delayed release | ||
1 |
|
Internal Photo | Internal Photos | 5.07 MiB | December 09 2022 / June 07 2023 | delayed release | ||
1 |
|
External Photo | External Photos | 500.64 KiB | December 08 2022 / June 07 2023 | delayed release | ||
1 |
|
Product Label | ID Label/Location Info | 398.83 KiB | December 08 2022 / December 09 2022 | |||
1 |
|
Agent Authorization Letter | Cover Letter(s) | 319.92 KiB | December 08 2022 / December 09 2022 | |||
1 |
|
Application Declaration | Cover Letter(s) | 234.95 KiB | December 08 2022 / December 09 2022 | |||
1 |
|
Confidential Request Letter | Cover Letter(s) | 420.47 KiB | December 08 2022 / December 09 2022 | |||
1 |
|
Test Report EMC | Test Report | 1.22 MiB | December 08 2022 / December 09 2022 | |||
1 |
|
Test Setup Photo | Test Setup Photos | 1.92 MiB | December 08 2022 / June 07 2023 | delayed release |
1 | User Manual | Users Manual | 1.89 MiB | December 08 2022 / June 07 2023 | delayed release |
Laser marking system C210 HARDWARE MANUAL Revision.1.1 C210 Hardware Manual Document Information LegislationRevision History Date Version Description 2022.10.11 2022.11.23 1.0 1.1 Document Legislated IZI-CODE V0 Renewal 2 / 49 C210 Hardware Manual Contents 1. Laser Safety Information 6 1.1 1.2 L a s e r Ty p e 6 Related Regulation 6 1.3 Management Method 7 1.4 Safety Warning and Sticker Information 10 2. Laser Introduction and Structure .... 12 2.1 2.2 2.3 2.4 La s er I nt rod uct i on . . . 1 2 Before Starting ............. 12 St r uc t u re . . . . . . 15 Technical Information ..... 20 3. Laser Operation . 22 3.1 Order of Operation ..22 3.2 3.3 Emergency Stop .... 23 Emergency Stop Release .... 23 4. User Interface .. 24 4.1 User Interface Pin Map (D-sub 25P connector) . 24 4.2 4.3 Pin description of User Interface.. 25 Binary Input Signal Table 26 4.4 User Interface Connection Examples ..27 4.5 Encoder (D-SUB 9P connector) .31 5. Hardware ..... 32 5.1 5.2 5.3 5.4 Laser Source ..... 32 Scanner ...... 33 Lens .34 Control Board ..... 35 3 / 49 C210 Hardware Manual 5.5 5.6 5.7 Interface Board ..... 36 Power Supply ..... 37 Cooling System ..... 38 6. Maintenance and Repair ..... 39 7. Troubleshooting .. 40 7.1 7.2 7.3 7.4 7.5 7.6 7.7 Level.1 Abstract ...... 40 Level.1 Main Power Failure ..... 41 Level.1 Key Switch Error ..
- READY LED Malfunction ......
- Consistent ERROR LED ............42 Level.1 Laser Shooting Error ..43 Level.1 Marking Power Adjustment 44 Level.1 PC Start Failure 45 Level.1 EZCAD2 Software Driver Error IMC_OpenDriver Fail 46 8. RMA ..47 9. Customer Inquiries ...48 4 / 49 C210 Hardware Manual Warning This product is a Class 4 laser product. The precaution concerning this class must be strictly observed. The safety precautions mentioned and proposed in this manual must be strictly observed. Extra care during use is mandatory to minimize the possibility of equipment damage or personal injuries. Users must not abruptly disengage or apply strong force to the equipment as well as emitting the laser beam to humans. Severe damage can be caused when the laser beam touches the eyes of human. Therefore, users must use protection goggles to prevent eye injury. In addition, we recommend wearing safety glasses and other safety equipment since every direct/indirect exposure of laser beams are very dangerous. The safety mechanisms and hazard prevention mechanisms supplied by IZI-
CODE does not fully satisfy the local factory inspection organizations of clients, safety rules, and national regulations of the competent country, and it does not guarantee that it is in compliance with legal or other requirements. Therefore, the system installer shall be responsible for verifying any necessary regulations prior to installing the safety mechanisms to prevent potential hazards that may be caused by the laser marking equipment. 5 / 49 C210 Hardware Manual 1. Laser Safety Information 1.1 Laser Type Laser is categorized into many types depending on the stimulating mechanism. Laser beam radiation is very hazardous if exposed to human bodies. Consequently, many countries have established related requirements and compliance requirements, and the lasers are classified according to its level of risk. ANSI Z136.1-2014 Class 1 Class 1M Class 2 Class 2M Class 3R Class 3B Lowest risk level, non-hazardous Hazardous if using focused optical system Blinking the eyes can prevent hazards (0.25 seconds) Potential hazard even under 0.25 seconds of using focused optical system Hazardous if laser beam enters the eyes Hazardous if looking into visible or invisible laser beam source that may damage the eyes due to direct or indirect reflections. Reflected light at maximum output is also hazardous Class 4 Projecting direct or indirect laser beam is very dangerous Risk of casing damage to eyes, skin, or risk of fire Strict control measures are required 1.2 Related Regulations IZI-CODE laser system complies with the basic safety requirements of ANSI Z.136.1-
2014(American National Standards Institute) and IEC60825-1 regulations (requirements), which are commonly applied internationally. Amendments to these regulations have recently been renewed. The amendments prescribe that only trained personnel shall have restricted access to the laser equipment, and signs indicating potential risks must be attached. 6 / 49 C210 Hardware Manual 1.3 Management Method Furthermore, laser products belonging to this class require extreme care when handling, and operation manuals, risk prevention mechanisms, etc. must be established to lower the class (risk level) for safer operation. We propose a management method that finely divides technical management areas and administrative management areas. Please strictly observe the management methods for implementation in your industrial site. Technical Management Methods Technical management is an installation that are integrated in the laser system to contemplate the possible exposures. Interlock System Interlocks are a common safety feature and are designed so that work can only be performed when the laser equipment is ready for operation. While the system operates and this signal activates, the error alarm LED lit and the laser stops working. Types of interlock includes UI interlock signals, laser source abnormality alarm signals, etc. Access Key According to safety regulations, the equipment is designed to convey power to the laser source only after turning on the power and the access key. Administrative Management Administrative management refers to a guidebook that provides information for technical management, explaining regulation and operation. Audible and Visible Emission Indicator Warning signs concerning exposure to radiation. Laser beams irradiate invisible infrared lasers, which may cause serious eye damage or burns. Therefore, safety stickers must be attached to the equipment to increase risk awareness for users. 7 / 49 C210 Hardware Manual Beam output This label should be located at the entrance of laser and there is a label in front of the laser head. In hence, all users have to treat the equipment more carefully. Warnings When the laser system is operating, be aware not to expose your eyes or skin directly to the Laser beam emitting from the marking head lens.
(See picture above) Use and Education for Personal Protection Equipment Eye Protection: Equip protection goggles depending on the laser type, wavelength and output level. (OD 3+, DI LB4 @ 5200-10,600nm) Skin Protection: Do not expose your skins to the laser and clothes, gloves must be fire resistant. Restrictions and SOP (Standard Operating Procedure) from the manufacturer company, Laser Safety Officer (LSO) or Laser Safety Committee Laser Control Restriction Equipment must be used by a professional employee from the manufacturer or a laser safety manager. Access to the place where the laser is installed must be regulated for ensuring safety. Standard Operating Procedure Operation manual and emergency measurements should be placed next to the equipment to use at any time. 8 / 49 C210 Hardware Manual Appropriate Environment for Installation Clean and Cool Area: The installation site must be isolated from dust, oil, or other contaminants. Such elements may lead to difficulties for maintenance and repair, or shorten the lifespan of the laser equipment. The fan opening of the controller and the head part must be kept clean at all times. Also, it is recommended to install a vacuum system or air conditioning system. A controlled room with warning labels: Preparations for potential hazards must be provided at all times, and safety must be the first and foremost priority. (Safety cover, authorized personnel only) Fire and Electrical Safety All reflective objects must be removed from the laser installation area. Fire safety: If the laser beam comes into contact with combustible substances, it may cause fire. In order to prevent such incidents, a fire extinguisher must be available near the laser equipment at all times. Also, in order to prevent laser beam reflections, adequate provisions must be made to all surface that surrounds the laser equipment, including the walls. The window curtains must be treated for flame resistance. Electrical safety: Considering the fact that the laser equipment has high-voltage electrical circuits, an adequate electrical safety measures must be practiced at all times. Proper power must be supplied to the laser equipment and the use of extension cables for supplying power to the laser equipment is prohibited. Electric shock accident: The laser equipment must be grounded and the bottom of the equipment must be free of moisture. Also, operators must have caution to prevent spillage of liquid over the laser equipment which could lead to unexpected electric shock accidents. Inspection: Installation of electrical safety mechanism to prevent accidental laser irradiation is mandatory. Functional safety inspections on all cords, switches, circuit breakers, etc. must be performed on a regular basis. 9 / 49 C210 Hardware Manual 1.4 Safety Warning and Sticker Information Label info Safety Warning and Labels Laser Beam Warning Label 1
(Stick to top of marking head) Laser Beam Warning Label 2
(Stick to side part of controller and top of marking head) Laser Beam Warning Label 3
(Stick to the front-top part of marking head) Caution and Warning Label Laser Danger Label
(Stick to top of marking head) 10 / 49 C210 Hardware Manual Label info Safety Warning and Labels Laser Aperture Label
(Stick to the front-bottom part of marking head) Product Label
(Stick to the rear-bottom part of controller) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications (including the antennas) to this device that are not expressly approved by the manufacturer may void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Lens Label 11 / 49 C210 Hardware Manual 2. Laser Introduction 2.1 Laser Introduction and Structure IZI-CODE laser series are designed to mark (dynamic or static) serial numbers, desired characters, or images on the surface of paper or plastic manufactured products. Basic laser wavelength is 10,600nm and it is within the infrared range of the light spectrum meaning that it is not visible to our eyes. The wavelengths generated from this laser system requires extra caution because it could potentially cause serious damage to the eyes. Also, damage to the skin or other body parts may vary depending on the lasers power level and exposure duration. 2.2 Before Starting All users are required to wear a certified laser protection goggles at all times when operating a laser equipment that doesnt have a safety cover. If you operate the equipment without understanding the function of each component, it may cause serious damage to the equipment. Therefore, it should be operated under the authorization of an expert or trained personnel after acquiring sufficient knowledge. This equipment must never be operated with interlocks or any other components disengaged. By turning OFF the Locker Switch (Main Power Switch), the products power completely cuts off. Box Contents The box includes a controller assembly and a head assembly on the top, securely packaged with PE foam. Various accessories (cables, manuals, etc.) are included in the bottom space. 12 / 49 C210 Hardware Manual Basic Parts & Accessories Provided A list of parts and accessories given when purchasing the equipment Controller Marking Head CO2 Cable Scanner Cable Key Interlock 13 / 49 C210 Hardware Manual UI cable(Option) Laser Power Key Power Cable This is an AC Power Cable with two ferrite cores applied. Model Name: ZCAT2035-0930 Manufacturer: TDK 110mm x 110mm Lens USB Hardware Manual Quick Start Manual Software Manual Software Backup File 14 / 49 C210 Hardware Manual QC Card, QC Report Fuse 2EA (Spare) Wrench Bolts 4EA (M6 *10) Square Spring Nuts 4EA 15 / 49 C210 Hardware Manual 2.3 Structure Hardware Components IZI-CODE Laser C series is comprised with controller and marking head. The controllers interior consists of a power supply, laser source, and a signal processing system (Control board, interface boards, etc.). The marking heads interior are composed of laser head which emits the laser beam, scanner, F-Theta lens and other parts. The marking head and controller must be installed within 2m distance. Also, this product is capable of syncing with barcode readers and automated equipment processing system to be used as a Built-in equipment. The Controller fits into a 19 Rack (4U), and the marking head can be mounted by using the sliding spring nut on the bottom of the head (Intervals between nuts are 80mm) and M6 Bolts. Front View (Controller) Status LED PC Power Switch PC USB Port Laser Power Key Switch Emergency Stop Button Main Power Switch Ready (BLUE), Error (RED) status LED PC power switch USB port (2 front, 4 rear) Laser source power ON/OFF key switch Emergency stop button Main power ON/OFF switch 16 / 49 C210 Hardware Manual Rear view (Controller) Interlock
/ UI Port Scanner Port CO2 Port VGA Port USB Port PC LAN Port Encoder Port EMC Power Module Switch Power Plug Port DC PORT, HDMI, DVI and Aux ports cannot be used. 24V Open collector type encoder port Interlock key or UI cable port Controller and scanner cable port Controller and CO2 laser source cable port Power plug port to supply main power EMC Power module switch VGA Monitor port PC LAN port (2 rear) 17 / 49 C210 Hardware Manual Front view (Marking Head) Marking status LED Scanner 16 Scanner guide beam Switch 17 19 Lens 18 Scanner guide beam BLUE LED ON: Marking(in process) / BLUE LED OFF : Marking(ready to mark) 16E The scanner will target the object and emit a laser beam that were generated from the laser source. A17E Scanner guide beam ON / OFF switch A18E The interval between these two scanner guide beams are 65mm and its used for adjusting the height between the marking head and the targeting object(refer to page 34, focal length) A19E F-Theta lens (refer to page 34) Rear view (Marking Head) Scanner Port CO2 Port Controller and scanner cable port Controller and CO2 laser source cable port 18 / 49 C210 Hardware Manual Hardware Connection Each part of the laser marking system must be interconnected using shielded cables. When control signals are sent from the laser control board to the interface board attached to the controller, the interface board converts the received signals into an independent signal system to send to each control part. The independent signals converted from the control board are connected to the CO2 cable and scanner cable, allowing the laser source and scanner control unit to synchronize and mark the target. The connection terminals are illustrated in the image below. These connectors have been designed according to a pre-planned Pin map, thus, it must be connected correctly. One of the power lead-in wires which is grounded must be separated from the power line and must be connected to the laser system at all times. The reason for using a ground connection between the laser system and the electrical power is for personal safety and system protection. In regards to operation safety, the ground connection can be regarded as low impedance (solely for safety purposes), which helps to protect the user and the equipment from the occurrence of dangerously high voltage while using the system. Impedance connection at high-frequency level cannot be presumed, and protection at high frequency cannot be guaranteed. 19 / 49 C210 Hardware Manual Warning The electrical system must be grounded at all times, and the ground connection must be inspected for safe operation. The ground connection must not be removed for any System Structure reason. Laser Beam Generator A laser source which emits and controls the laser beam by receiving a signal from the electronic control part. Scanner the target surface by refracting through the reflective The laser beam comes out from the source to reach mirrors (X and Y mirrors) and F-Theta lens. Electronics Control It is largely divided into power control, scanner control, It is the main part for controlling the marking system. source output control, and external interface. Cooling Unit
(Forced Air Cooling) Since lasers irradiate a lot of heat, it is necessary to maintain adequate system temperature at all times through a cooling system. IZI-CODE laser system contains a cooling fan installed inside the controller. Warning A specific amount of free space must be assured for the fan openings. Please be aware that obstructing the air circulation path could incur high temperature which could lead to laser malfunction. 20 / 49 C210 Hardware Manual 2.4 Technical Information Specifications Model name C210 Laser output 10W (Wavelength: 10600 nm) Scanner guide beam output Lens Up to 1mW peak (Wavelength: 655nm) 110mm X 110mm (Basic) 70mm X 70mm (Option) Main power supply 100~240VAC, 50/60Hz, 650 W Environmental condition Temperature: 15C(59F) ~ 40C(104F), optimal workplace temperature Humidity: Not condensed from 10% to 80% without vibration Operation method Pulse Wave, Continuous Wave Pulse 0kHz ~ 25kHz , 0% ~ 100%(Duty Cycle) Laser Source Marking head Scanner F-Theta Lens Subsidiaries Cables and other accessories Cooling method Forced air cooling Weight Control
*Safety Specification Total: 27.8kg Controller: 15kg Marking Head: 12.8kg Full graphic interface software using PC Encoder, sensor, user interface (UI) Used place Indoor Pollution degree OVERVOLTAGE CATEGORY 2 2 MAINS supply voltage fluctuations 10 %
Altitude Up to 2000m 21 / 49 C210 Hardware Manual Hardware Schematics 22 / 49 C210 Hardware Manual 3. Laser Operation 3.1 Order of Operation Warning Using the equipment arbitrarily without following the guideline could cause injury from the emitted laser beam. Preparation Check all connections and power cords. Connect the interlock key or UI cable to the User I/F port. Connect the CO2 cable from controller CO2 port to marking head CO2 port. Connect the scanner cable from controller scanner port to marking head scanner port. Power Turn ON the main power switch. Soon the error LED (red) will light up along with powering the Ready Error system. The illuminating components (LED, normal lamp, warning lamp, etc.) connected to the UI cable will light. There is some noise when the audible components (buzzer, etc.) are connected. Laser Preparation Turn the key switch (Laser Power) to ON position to activate the laser source. Ready Error The error LED will turn off and ready LED (blue) will light up. The illuminating components (LED, normal lamp, warning lamp, etc.) connected to the UI cable will maintain its light. There is consistent noise when the audible components (buzzer, etc.) are connected. PC Setup Press the PC ON switch to boot the PC. Later on, the PC ON switch (white) will light up. Software Setup Run the EzCad software from your PC. Check laser and software status. Check marking data and parameter settings. When creating new marking data, test the marking first before applying the 23 / 49 C210 Hardware Manual parameters. Start Marking Below the screen of the software, click the Mark button or press F2 to start marking. 3.2 Emergency Stop Emergency Stop Press the Emergency Stop button on the front panel when unexpected situations occur When pressed, the error LED will light. 3.3 Emergency Stop Release Turn Off the Laser Source Power Turn OFF the key switch on the controllers front panel. Soon the error LED will light up. Ready Error Ready Error Environmental Inspection after Emergency Stop Inspect the cause of the emergency stop and the nearby environment to rearrange. Releasing the Emergency Stop Turn the emergency stop button on the controllers front panel to return to its normal state. Soon the error LED will light up. Laser Preparation after Emergency Stop On the front panel, turn ON the key switch to power the laser source. The error LED will go out and ready LED will light up. Check your target and start marking again. Ready Error Ready Error 24 / 49 C210 Hardware Manual 4. User Interface 4.1 User Interface Pin Map (D-SUB 25P Connector) Pin No. Pin Name Type 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Not used Not used Not used Not used INCOM Binary 8 Binary 7 Binary 6 Binary 5 Binary 4 Binary 3 Binary 2 Binary 1 G24V Marking Start P24V Not used Interlock Stop Interlock COM Not used Not used OUTCOM Marking Done Marking Ing Software Ready IN IN IN IN IN IN IN IN IN OUT IN OUT IN IN IN OUT OUT OUT 25 / 49 C210 Hardware Manual 4.2 User Interface (Pin description) Pin Name Pin Description INCOM(5) COMMON terminal for the user input signals. This terminal is used with binary combination when selection message signals are used. The message selection signal designated from user. User can select the message with binary combination using these bits. Binary 1~8(6~13) A maximum of 256 messages can be allocated and users can choose either the exterior control message to mark. Pins of Binary 1 ~ 8 and INCOM pins are interconnected. G24V(14)
(Do not use for any other purpose than supplying power to A ground sensor power input for marking start operation. Marking Start(15) the sensor. It could cause damage to the equipment.) Sensor signal input for marking start signal. (Connects only NPN type) A +24V Sensor Power input for marking start operation. P24V(16)
(Do not use for any other purpose than supplying power to the sensor. It could cause damage to the equipment.) Interlock Stop(18) Interlock COM(19) This is the interlock pin. The two pins must be interconnected to operate the laser. COMMON terminal for the user output signals. The common terminal reads off the state of the laser equipment and OUTCOM(22) where the supplied voltage to the OUTCOM terminal has been activated, the relevant signal goes through the internal relay and meets. (Use external power unit +24V or GND) Marking Done(23) The output signal after completion of printing. User can change the signal output time in software settings. Marking Ing(24) The output signal while laser is printing.
(Marking head LED turns on and prints concurrently) Software The output signal notifying that software is at normal state Ready(25) and ready. 26 / 49 C210 Hardware Manual 4.3 Binary Input Signal Table The user input signals are designed to allow the simple automatic operation. Through the implementation of binary codes (See the bottom table), there are a maximum of 255 signal table. With selected bits you can mark by selecting a certain message number. Please refer to the software manual for detailed information. Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Position in Table 0 0 0 1 1 0 0 0 1 1 0 0 0 1 1 0 0 0 1 1 0 0 0 1 1 0 0 0 1 1 0 0 1 1 1 0 1 0 0 1 0 1 2 254 255 27 / 49 C210 Hardware Manual 4.4 User Interface Connection Examples Machine Status LED Example UI PORT Cathode(-) Anode(+) P24V(16) G24V(14) Connect P24V pin to Anode(+) pin, and connect G24V pin to Cathode(-) pin. LED will light when the laser systems main power is at normal input state. Warning The above figure is an example of an LED connection. Such devices other than LED can be installed under the user's request. (refer to page 22) Please be aware this part of the UI connection is pre-
installed by the manufacturer and thus should not be arbitrarily removed or replaced. 28 / 49 C210 Hardware Manual Interlock Example UI PORT USER Normally Close Interlock COM(19) Interlock STOP(18) Connect the Interlock STOP pin and the Interlock COM pin. Laser system stops when both pins are open. Caution : Laser system will operate when both pins are connected. (Normally Close) Input Pin (Binary) Example UI PORT Binary 1(13) Binary 2(12) Binary 3(11) Binary 4(10) Binary 5(9) Binary 6(8) Binary 7(7) Binary 8(6) INCOM(5) Connect the binary pins to INCOM pin. Caution : INCOM pin must not be connected to external powers. (System will malfunction) 29 / 49 C210 Hardware Manual Input Pin (Marking Start) Example NPN Sensor NPN sensor internal circuit UI PORT
+24V OUT P24V(16) Marking Start(15) GND G24V(14) Joint the P24V and G24V to the sensors power supply pin, and connect the sensors output pin to the marking start pin. Foot Switch Foot switch internal circuit Normally Open A B UI PORT Marking Start(15) G24V(14) Joint the G24V pin to the A pin (Pole or COM), and connect the B pin (Normally Open) to the marking start pin. 30 / 49 C210 Hardware Manual Output Pin Example External Power +24V UI PORT Internal Relay
+24V Output
( ) Software Ready(25)
+24V Output
( ) Marking Ing(24)
+24V
+24V Output
( ) Marking Done(23) External Power +24V Connection OUTCOM(22) System Exterior System Interior When OUTCOM pin and +24V is connected, the +24V connected to the OUTCOM will output. External Power GND UI PORT Internal Relay GND Output
( ) GND Output
( ) Software Ready(25) Marking Ing(24) GND Output
( ) Marking Done(23) External Power GND Connection OUTCOM(22) System Exterior System Interior When OUTCOM pin and GND is connected, the GND connected to the OUTCOM will output. 31 / 49 C210 Hardware Manual 4.5 Encoder (D-SUB 9P connector) Pin No. Pin Name 1 2 3 4 5 6 7 8 9 P24V Not used Encoder A+
Encoder B+
Not used Not used Not used G24V G24V Only 24V Open collector type encoder can be used. Type OUT IN IN OUT OUT 32 / 49 C210 Hardware Manual 5. Hardware 5.1 Laser Source Laser Source Main Specifications Wavelength Power Output 10.6m 10W Power Stability (typical, after 3min) 10%
Mode Quality (M)
<1.2 Output Beam Waist Diameter (at 1/e) 3.5mm Beam Divergence (full angle) 4mrad Ellipticity Polarization Rise Time
<1.2 Linear, Vertical
<150s Operating Frequency 0kHz to 25kHz Power Supply DC Input Voltage Maximum Current Maximum Heat Load Cooling Coolant Temperature 30 VDC 7 A 300 W
<40C Minimum Flow Rate 250CFM, 2 required (air) Environmental Operating Ambient Temperature 15C to 40C Maximum Humidity 95%, non-condensing Dimensions (L W H) Physical Weight 42971107 mm (16.9 2.84.2 inches) 4.1 kg (9.0 lbs) IZI-CODE CO2 Laser consists of a body and head assembly, and these two parts are connected by a Scanner cable and a CO2 dedicated cable. Therefore, it requires extra care because the source will be unusable if this cable is severely bent or cut. This laser generator unit detects overheating and DC voltages to automatically create an error signal and stop the laser generator whenever a negative influence is caused to the laser source. 33 / 49 C210 Hardware Manual 5.2 Scanner The laser beams marking speed and precision are completely dependent on the scanner mirror movements because it has nearly no mass or any transposition. Therefore, the laser marking controller operates by receiving the position data from the electro-current sensors connected to the X, Y Galvanometer fixed on the scanner axis. The angular movement of mirrors corresponds with one of the axis (X or Y) and one of the message dots of X/Y polar coordinate. In the case of dynamic printing, while creating the message properties the mirrors will move as the conveyor moves. Scanner Specifications Basic Performance Type Aperture Wavelength Galvo Protocol Normal High Speed 10mm 10mm 10.6 m XY2-100 Repeatability
<22 rad
<8 rad 1%Of Full Scale Dynamic Performance 10%Of Full Scale Non-Linearity 0.3ms 0.7ms
<0.4%
0.21ms 0.71ms
<0.2%
Typical Speeds Drift Over 8 Hours
<0.3mrad
<0.5mrad Max. Scanning Speed 6000mm/s 12000mm/s Max. Positioning Speed 15m/s 23m/s Gain Error Zero Offset
<5mrad
<5mrad
<5mrad
<5mrad Optical Performance Operating Temperature 10-40 0-45 Power Requirements 15V 3A 15V 2A Weight 1.9kg 1.95kg 34 / 49 C210 Hardware Manual 5.3 Lens The F-theta lens concentrates the laser wavelengths focus radiating from the laser generator to apply markings on the product surface. The F-theta lenses are categorized according to the size of the lens, and each lens size has varying marking areas and focal lengths. Check the focal length according to your lens size to adjust the distance between the scanner and the marking product. Also, the focal length is fundamentally set to have two scanner guide beams correspond. (Refer to the figure below) There are two lens size:
70mm X 70mm and 110mm X 110mm. Users can select a product with their desired specification. Lenses are very fragile and it requires extra care for maintenance and handling. Refrain from making any contact with the lens surface and it must be cleaned with optical tissues and designated solvents (acetone or alcohol). Focal length m m 5 2 1 70 X 70mm m m 0 2 2 110 X 110mm Cleaning Sequence for Lens and Scanner Mirror Laser Off Remove the lens from the head scanner and move to a safe spot Carefully clean the lens surface using clean paper and acetone Use ethanol to clean the inside of the scanner mirror
(Using acetone to clean the mirror could remove the surface coating) Repeat until the lens is completely clean. Check the status of the lens surface and reassemble 35 / 49 C210 Hardware Manual The lens and scanner must be cleaned on a regular basis to prevent pollution. Contaminants on the lens surface may reduce the lens transmission rate and it may lead to the degradation of marking power and quality. 5.4 Control Board The control board is inserted into the Controller and it must be connected to the laser system using cables. The scanners X and Y axis movement is controlled according to the supply of the digital signal format sent from the internal control board. Moreover, the laser generators output control and user interface port, encoder, sensor etc. are synchronized through the exterior signals which allows to control the laser system. Control Board Drawing 36 / 49 C210 Hardware Manual 5.5 Interface Board The internal interface board is designed to transmit signals using photo couplers and diodes to ensure the safety of each component. It is an integrated signal transmission board designed to control various types of input signals. Interface Board Drawing 37 / 49 C210 Hardware Manual 5.6 Power Supply Each part of the laser system requires maintaining a stabilized and adequate volume of power supply Power Supply Main Specifications Laser Source Input Spec 100~264 VAC, 50/60Hz Output Spec 27VDC (26~31.5V), 11.9A ( adjusted to 30V) Working Temp
-30~+70 Working Humidity 20~90% RH non-condensing Input Spec 100~264 VAC, 50/60Hz Internal Main Output Spec 24VDC, 4.5A Working Temp
-30~+70 Working Humidity 20~90% RH non-condensing Input Spec 100~264 VAC, 50/60Hz Scanner Output Spec 15VDC, 5A Working Temp
-30~+70 Working Humidity 20~90% RH non-condensing Input Spec 100~264 VAC, 50/60Hz PC Output Spec 12VDC, 4.2A Working Temp
-30~+70 Working Humidity 20~90% RH non-condensing 38 / 49 C210 Hardware Manual 5.7 Cooling System Since laser generation produces high temperatures, it is necessary to maintain an adequate system temperature using a cooling system. Fail to do so may cause overheating of the equipment, which may lead to system malfunction. To prevent such incidents, IZI-
CODE laser system has 1 fan installed inside the controller and 2 fans inside the marking head. Cooling System Main Specifications Rated Voltage 24VDC Operating Voltage Range 14 to 26.4VDC Input Current 0.4A(max 0.5) Input Power 9.6W Speed 4800RPM Max. Air flow 102.59 (Min 92.33) CFM Size 92mm * 92mm * 25mm 39 / 49 C210 Hardware Manual 6. Maintenance and Repair Frequent Inspection Regular Inspection Lens contaminants Check once a week CONTROLLER NET FILTER Check once a month MARKING HEAD NET FILTER Check once a month Equipment exterior Check once a month Computer Frequently scan virus and back up computer Caution - Use of control or Maintenance and repair of equipment may result in hazardous radiation exposure. 40 / 49 C210 Hardware Manual 7. Troubleshooting 7.1 Level.1 Abstract The manual is comprised with useful information for IZI-Code laser users to cope with common technical issues. Our objective is to ensure user safety along with protecting the laser system from undergoing severe damage. Troubleshooting Level 1 provides a procedure of what users should check to handle the equipment properly. It is a basic procedure for users to effectively solve problems sequentially by referring to the questionnaires. We recommend users to deal with certain issues by following through this troubleshooting process. If users cannot solve the issue or needs further information, please send an RMA to our CS department for inquiry and request. (RMA form is on the last page) 41 / 49 C210 Hardware Manual 7.2 Level.1 Main Power Failure Status check Check the EMC power module switch Procedure Unsolved Connect the plug OFF ON Status check Check the fuse socket Turn ON the EMC power module switch Procedure Unsolved Status check Check the electricity supply Procedure Unsolved Inspect the assembly lines that shares the same electricity. RMA Application Office Hours: 8:30 ~ 17:30(GMT+9) http://www.taechueng.co.kr 82+ 31-359-9601 HQ: Deokjeolchangmal-gil, Jeongnam-myeon, Hwaseong-si, Gyeonggi-do, Republic of Korea R&D: 27, Dongtancheomdansaneop 1-ro, Hwaseong-si, Gyeonggi-do, Geumgang-
Pentarium IX Tower #A3109, Republic of Korea Solved Normal Solved Normal Solved Normal 42 / 49 C210 Hardware Manual 7.3 Level.1 Key Switch Error Ready LED Malfunction Consistent error LED Status check Check the rear panel connection Procedure Unsolved Check interlock key connection.
-2 Connect the interlock pin if using a UI cable. Status check Did you reset the emergency switch?
Procedure Unsolved RMA Application Turn right to reset Office Hours: 8:30 ~ 17:30(GMT+9) http://www.taechueng.co.kr 82+ 31-359-9601 HQ: Deokjeolchangmal-gil, Jeongnam-myeon, Hwaseong-si, Gyeonggi-do, Republic of Korea R&D: 27, Dongtancheomdansaneop 1-ro, Hwaseong-si, Gyeonggi-do, Geumgang-
Pentarium IX Tower #A3109, Republic of Korea Solved Normal Solved Normal 43 / 49 Solved Normal Solved Normal Solved Normal C210 Hardware Manual 7.4 Level.1 Laser Shooting Error Status check Are there lights emitting in Ready LED?
Procedure Refer to Troubleshooting (Page 39) Level.1 Key Switch Error Unsolved Ready LED Malfunction. Consistent error LED. Status check Check the lens cover Procedure Remove the lens cover. Unsolved Lens Cover Status check Hows the marking distance?
Procedure Adjust the distance of marking product and laser scanner. Unsolved Lens Size 70x70 110x110 Height Height 125mm 220mm RMA Application The lens size indicated are standard. Height may differ depending on the lens size Office Hours: 8:30 ~ 17:30(GMT+9) http://www.taechueng.co.kr 82+ 31-359-9601 HQ: Deokjeolchangmal-gil, Jeongnam-myeon, Hwaseong-si, Gyeonggi-do, Republic of Korea R&D: 27, Dongtancheomdansaneop 1-ro, Hwaseong-si, Gyeonggi-do, Geumgang-
Pentarium IX Tower #A3109, Republic of Korea 44 / 49 Solved Normal Solved Normal Solved Normal C210 Hardware Manual 7.5 Level.1 Marking Power Adjustment Status check Check software settings Procedure Check marking parameter Unsolved Uncheck User default param Increase power(%) to appropriate rate Decrease frequency and speed(mm/s) value Status check Check marking distance Procedure Adjust the distance of marking product and laser scanner Lens Size 70x70 110x110 Unsolved Height Height 125mm 220mm The lens size indicated are standard. Height may differ depending on the lens size Status check Are there any contaminants in lens?
Procedure Clean the lens Turn OFF the engine and disengage the lens Use acetone and paper towel to clean lens
*Wipe it out by moving your hands clockwise, counterclockwise. Keep cleaning until all contaminants are removed. Assemble the lens back to the scanner Unsolved Disengage Reassemble RMA Application Office Hours: 8:30 ~ 17:30(GMT+9) http://www.taechueng.co.kr 82+ 31-359-9601 HQ: Deokjeolchangmal-gil, Jeongnam-myeon, Hwaseong-si, Gyeonggi-do, Republic of Korea R&D: 27, Dongtancheomdansaneop 1-ro, Hwaseong-si, Gyeonggi-do, Geumgang-
Pentarium IX Tower #A3109, Republic of Korea 45 / 49 Solved Normal Solved Normal C210 Hardware Manual 7.6 Level.1 PC Start Failure Status check Check PCs power switch Procedure Look at the front panel to confirm that the ON/OFF switch operates Unsolved When OFF When ON Status check Check PC monitor cable Procedure Back Panel VGA Unsolved VGA Monitor Re-connect the cable that are plugged on the back panel. Re-connect the cable that are plugged onto the monitor Replace a new cable HDMI cannot be used. RMA Application Office Hours: 8:30 ~ 17:30(GMT+9) http://www.taechueng.co.kr 82+ 31-359-9601 HQ: Deokjeolchangmal-gil, Jeongnam-myeon, Hwaseong-si, Gyeonggi-do, Republic of Korea R&D: 27, Dongtancheomdansaneop 1-ro, Hwaseong-si, Gyeonggi-do, Geumgang-
Pentarium IX Tower #A3109, Republic of Korea 46 / 49 C210 Hardware Manual 7.7 Level.1 EZCAD2 Software Driver Error Imc_OpenDriver Fail Status Check Check PC driver Procedure Verify driver installation:
Device manager Bjjcz device Laser mark control board V2 (USB) Unsolved Status Check Reboot your PC and open the program Procedure Unsolved RMA Application Office Hours: 8:30 ~ 17:30(GMT+9) http://www.taechueng.co.kr 82+ 31-359-9601 HQ: Deokjeolchangmal-gil, Jeongnam-myeon, Hwaseong-si, Gyeonggi-do, Republic of Korea R&D: 27, Dongtancheomdansaneop 1-ro, Hwaseong-si, Gyeonggi-do, Geumgang-
Pentarium IX Tower #A3109, Republic of Korea Solved Normal Solved Normal 47 / 49 C210 Hardware Manual 8. RMA Found any mechanical flaws or repairment is needed, please fill in the form below and reach to our closest service center or contact TAECHU ENGINEERING CO., LTD. Return Material Authorization Customer information Company name Street State IZI-CODE information Date Of Purchase Product State NO Contact person City Zip code Model Serial No. No Warranty Pass Damage impact YES( ) YES( ) F-theta Pass Pass Fiber lens pollution sticker state Fuse Fail( ) Pass Fail( ) state Fail( ) state Fail( ) Picture 48 / 49 C210 Hardware Manual Description 9. Customer Inquiries Head Office: 1, Deokjeolchangmal-gil, Jeongnam-myeon, Hwaseong-si, Gyeonggi-do R&D Center: 27, Dongtancheomdansaneop 1-ro, Hwaseong-si, Gyeonggi-do, Geumgang-
Pentarium IX Tower #A3109, Republic of Korea TEL: 82+ 31-359-9601 Fax: 82+ 31-359-3605 49 / 49
1 | Product Label | ID Label/Location Info | 398.83 KiB | December 08 2022 / December 09 2022 |
an ATLAS Model: C210 Serial:
FCC ID: 2A89W-C210 Power: 100 - 240V ~
50-60Hz, 650W Customer Service:
www.atlaslaser.com TAECHU ENGINEERING / MADE IN KOREA CEGTE 710405 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. an ATLAS Model: C210 Serial:
FCC ID: 2A89W-C210 Power: 100 - 240V ~
50-60Hz, 650W Customer Service:
www.atlaslaser.com MADE IN KOREA TAECHU ENGINEERING CO., LTD. CEATE 710405 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation
1 | Agent Authorization Letter | Cover Letter(s) | 319.92 KiB | December 08 2022 / December 09 2022 |
TAECHU ENGINEERING CO., LTD. 1, Deokjeolchangmal-gil, Jeongnam-myeon, Hwaseong-si, Gyeonggi-do, Republic of Korea, 18515 November 7, 2022 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road, Columbia, MD 21046 To Whom It May Concern:
I, the undersigned, hereby authorize SGS Korea Co., Ltd. and hereafter referred to as SGS Korea, to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by SGS Korea Co., Ltd. on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing SGS Korea as our agent, we still recognize that we are responsible to:
a) comply with the relevant provisions of the certification program;
b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints;
c) make claims regarding certification only in respect of the scope for which certification has been granted;
d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized;
e) upon suspension or cancellation of certification, discontinue use of all advertising matter TAECHU ENGINEERING CO., LTD. 1, Deokjeolchangmal-gil, Jeongnam-myeon, Hwaseong-si, Gyeonggi-do, Republic of Korea, 18515 that contains any reference thereto and return any certification documents as required by the Certification Division;
f) use certification only to indicate the products are certified as being in conformity with specified standards;
g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner;
h) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division;
i) keep a record of all complaints made known to the us relating to the products compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested;
j) take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification;
k) document the actions taken. This authorization is valid until further written notice from the applicant. Sincerely yours,
(Sign) Name/Title : Jongyong Sun / Director Company Name : TAECHU ENGINEERING CO., LTD.
1 | Application Declaration | Cover Letter(s) | 234.95 KiB | December 08 2022 / December 09 2022 |
SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Declaration Applicant Legal Business Name TAECHU ENGINEERING CO., LTD. Address Grantee Code FCC ID Authorized Contact Name Contact Email Contact Phone 1, Deokjeolchangmal-gil, Jeongnam-myeon, Hwaseong-si, Gyeonggi-do, Republic of Korea, 18515 2A89W 2A89W-C210 Jongyong Sun sunjy@taechueng.co.kr
+82-31-359-9601 I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare;
a) b) c) d) e) in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for:
labeling the equipment with the exact FCC ID as specified in this application,
(1)
(2) compliance statement labeling pursuant to the applicable rules,
(3) compliance of the equipment with the applicable technical rules, if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCCs technical requirements. in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. in accordance with ISO17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements.
(1)
(2)
(3) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing. the Applicant shall make provisions to always have a production sample available upon request by SGS, FCC and/or ISED. the Applicant shall, upon request by SGS, at the Applicants expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. f) neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a party for these purposes. g) the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc.(TCB) terms and conditions. Link to CFRs: https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs: https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100: https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Applicant Signature:
Date: 2022-11-07 Print Name:
Title:
*NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database Jongyong Sun Director Applicant Declaration Rev:0.0
1 | Confidential Request Letter | Cover Letter(s) | 420.47 KiB | December 08 2022 / December 09 2022 |
TAECHU ENGINEERING CO., LTD. 1, Deokjeolchangmal-gil, Jeongnam-myeon, Hwaseong-si, Gyeonggi-do, Republic of Korea, 18515 Nobember 07, 2022 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road, Columbia, MD 21046 Request of Confidentiality for FCC ID : 2A89W-C210 To Whom It May Concern:
Pursuant to Sections 0.457 and 0.459 of the Commissions Rules (CFR 47), and Section 552 (b) (4) of the Freedom of Information Act, TAECHU ENGINEERING hereby requests confidentiality and treatment of certain information accompanying this application. The materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. We are also hereby request Short-Term Confidentiality for 180 days after the grant as outlined in Public Notice DA 04-1705. This provision will give TAECHU ENGINEERING temporary confidentiality of commercially sensitive information prior to product release. The requested Permanent and Temporary Confidential exhibits are listed as follows:
CONFIDENTIAL LIST Permanent Short-Term 1 2 3 4 4 5 6 7 Block Diagram Operational Descriptions Schematics
External Photos Internal Photos Test-Setup Photos Users Manual TAECHU ENGINEERING CO., LTD. 1, Deokjeolchangmal-gil, Jeongnam-myeon, Hwaseong-si, Gyeonggi-do, Republic of Korea, 18515 The Applicant understands that pursuant to Rule 0.457, disclosure of this application and all accompanying documentations, where applicable, will not be made public before the date of the Grant for this application. Sincerely yours,
(Sign) Name/Title : Jongyong Sun / Director Company Name : TAECHU ENGINEERING CO., LTD.
1 | Test Setup Photo | Test Setup Photos | 1.92 MiB | December 08 2022 / June 07 2023 | delayed release |
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2022-12-09 | JAD - Part 15 Class A Digital Device | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2022-12-09
|
||||
1 | Applicant's complete, legal business name |
TAECHU ENGINEERING CO., LTD.
|
||||
1 | FCC Registration Number (FRN) |
0033059619
|
||||
1 | Physical Address |
1, Deokjeolchangmal-gil, Jeongnam-myeon
|
||||
1 |
Hwaseong-si, Gyeonggi-do, N/A
|
|||||
1 |
South Korea
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
U******@SGS.COM
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2A89W
|
||||
1 | Equipment Product Code |
C210
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
J******** S********
|
||||
1 | Title |
Director
|
||||
1 | Telephone Number |
+82-3********
|
||||
1 | Fax Number |
+82-3********
|
||||
1 |
s******@taechueng.co.kr
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
SGS Korea Co., Ltd
|
||||
1 | Name |
J**** C******
|
||||
1 | Physical Address |
4, LS-ro, 182 beon-gil
|
||||
1 |
Gunpo-si, Gyeonggi-do, 15807
|
|||||
1 |
South Korea
|
|||||
1 | Telephone Number |
+8231********
|
||||
1 | Fax Number |
82-31********
|
||||
1 |
j******@sgs.com
|
|||||
app s | Non Technical Contact | |||||
1 | Firm Name |
SGS Korea Co., Ltd
|
||||
1 | Name |
J**** K********
|
||||
1 | Physical Address |
4Fl, 4, LS-ro 182beon-gil
|
||||
1 |
Gunpo-siGunpo-si, Gyeonggi-do, 15807
|
|||||
1 |
South Korea
|
|||||
1 | Telephone Number |
+8231********
|
||||
1 | Fax Number |
82-70********
|
||||
1 |
j******@sgs.com
|
|||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 06/07/2023 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | JAD - Part 15 Class A Digital Device | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | LASER MARKING MACHINE | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
SGS Korea Co., Ltd
|
||||
1 | Name |
P**** H********
|
||||
1 | Telephone Number |
+82-3********
|
||||
1 | Fax Number |
+82-3********
|
||||
1 |
h******@sgs.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15B |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC