Pos: 1 /BAL/Vorlage-Module - kopieren/Titelseite @ 14\mod_1379667328971_6.docx @ 177061 @ @ 1 Datenlogger Data Logger Kurzanleitung 0572 2620, 0572 2621, 0572 2622, 0572 2623 Short instruction 0572 2620, 0572 2621, 0572 2622, 0572 2623
=== Ende der Liste fr Textmarke Inhalt ===
Pos: 4 /BAL/0970 2603 testo Saveris Restaurant Datenlogger BAL/01 Sicherheit und Entsorgung/01_01_04 BAL aufmerksam lesen @ 20\mod_1476692057505_6.docx @ 248464 @ @ 1 Lesen Sie diese Bedienungsanleitung aufmerksam durch und machen Sie sich mit dem Produkt vertraut, bevor Sie es einsetzen. Eine detaillierte Anleitung finden Sie unter dem Login der jeweiligen testo Anwendung: www.testo.com/login These commissioning instructions describe the basic operating steps. To find out how to handle the product safely and for detailed information, please refer to the manual of the respective testo Solution at: www.testo.com/login Pos: 5 /BAL/0970 2603 testo Saveris Restaurant Datenlogger BAL/01 Sicherheit und Entsorgung/01_00 Sicherheit und Entsorgung/1 Sicherheit und Entsorgung @ 20\mod_1476692218930_6.docx @ 248499 @ 1 @ 1 1 Sicherheit und Entsorgung Eine ausfhrliche Beschreibung fr das Tablet finden Sie unter www.sonymobile.com/support. Um bestimmte Funktionen dieses Gertes (vor allem das Messdaten-
Management) nutzen zu knnen, mssen Sie den Testo Cloud-
Nutzungsbedingungen zustimmen, die Sie unter dem Login der jeweiligen testo Anwendung auf www.testo.com/login finden. Um bei Einsatztemperaturen unter -10C die Batteriestandzeiten zu erreichen, sollten Energizer L91 Lithium Batterien AAA verwendet werden. Allgemeine Sicherheitshinweise Verwenden Sie das Produkt nur sach- und bestimmungsgem und innerhalb der in den technischen Daten vorgegebenen Parameter. Wenden Sie keine Gewalt an. Nehmen Sie das Gert nicht in Betrieb, wenn es Beschdigungen am Gehuse aufweist. Auch von den zu messenden Anlagen bzw. dem Messumfeld knnen Gefahren ausgehen: Beachten Sie bei der Durchfhrung von Messungen die vor Ort gltigen Sicherheitsbestimmungen. Temperaturangaben auf Sonden/Fhlern beziehen sich nur auf den Messbereich der Sensorik. Setzen Sie Handgriffe und Zuleitungen keinen Temperaturen ber 70 C
(158 F) aus, wenn diese nicht ausdrcklich fr hhere Temperaturen zugelassen sind. Fhren Sie keine Kontakt-Messungen an nicht isolierten, spannungsfhrenden Teilen durch. Transportieren und lagern Sie das Gert ausschlielich in dem mitgelieferten Koffer, um Beschdigungen am Sensor zu vermeiden. Lagern Sie das Produkt nicht zusammen mit Lsungsmitteln. Verwenden Sie keine Trockenmittel. Fhren Sie nur Wartungs- und Instandhaltungsarbeiten an diesem Gert durch, die in der Dokumentation beschrieben sind. Halten Sie sich dabei an die vorgegebenen Handlungsschritte. Verwenden Sie nur Original-Ersatzteile von Testo. Datenlogger BAL/01 Batterien und Akkus Die unsachgeme Verwendung von Batterien und Akkus kann zur Zerstrung der Batterien und Akkus, Verletzungen durch Stromste, Feuer oder zum Auslaufen von chemischen Flssigkeiten fhren. Setzen Sie die mitgelieferten Batterien und Akkus nur entsprechend den Anweisungen in der Bedienungsanleitung ein. Schlieen Sie die Batterien und Akkus nicht kurz. Nehmen Sie die Batterien und Akkus nicht auseinander und modifizieren Sie sie nicht. Setzen Sie die Batterien und Akkus nicht starken Sten, Wasser, Feuer oder Temperaturen ber 60 C aus. Lagern Sie die Batterien und Akkus nicht in der Nhe von metallischen Gegenstnden. Bei Kontakt mit Batterieflssigkeit: Waschen Sie die betroffenen Regionen grndlich mit Wasser aus und konsultieren Sie gegebenenfalls einen Arzt. Verwenden Sie keine undichten oder beschdigten Batterien und Akkus. Laden Sie den Akku nur im Gert oder in der empfohlenen Ladestation. Brechen Sie den Ladevorgang unverzglich ab, falls dieser in der angegebenen Zeit nicht abgeschlossen sein sollte. Entnehmen Sie den Akku sofort aus dem Gert oder der Ladestation, wenn er nicht ordnungsgem funktioniert oder Anzeichen von berhitzung zeigt. Akku kann hei sein!
Entnehmen Sie den Akku bei lngerem Nichtgebrauch aus dem Gert, um eine Tiefentladung zu vermeiden. Pos: 13 /BAL/0970 2603 testo Saveris Restau5_6.docx @ 248787 @ 2 @ 1 Entsorgung Entsorgen Sie defekte Akkus / leere Batterien entsprechend den gltigen gesetzlichen Pos: 16 /BAL/0970 2603 testo Saveris Restaurant Datenlogger BAL/01 Sicherheit und Entsorgung/01_03 Entsorgung/Entsorgung @ 20\mod_1476694686141_6.docx @ 248859 @ @ 1 Bestimmungen. Fhren Sie das Produkt nach Ende der Nutzungszeit der getrennten Sammlung fr Elektro- und Elektronikgerte zu (lokale Vorschriften beachten) oder geben Sie das Produkt an Testo zur Entsorgung zurck.
@ 1 1 Safety and removal Pos: 6 /BAL/0970 2603 testo Saveris Restaurant Datenlogger BAL/01 Sicherheit und Entsorgung/01_01 Zu diesem Dokument/2 Zu diesem Dokument @ 20\mod_1476692312890_6.docx @ 248607 @ 2 @ 1 You will find a detailed description for tablets at www.sonymobile.com/support. In order to be able to use certain functions of this instrument (in particular the measurement data management), you need to accept the Testo Cloud terms and conditions of use, which you will find in the login area of the respective testo solution at www.testo.com/login.
@ 248679 @ @ 1 To achieve the battery lifetime at operating temperatures below -10 C, Energizer L91 Lithium batteries AAA should be used.
@ 248679 @ @ 1 General safety instructions Only use the product properly, for the purpose intended and within the parameters specified in the technical data. Do not apply any force. Do not commission the instrument if there are signs of damage on the housing. Dangers may also arise from the systems being measured or the measuring environment: always comply with the locally valid safety regulations when carrying out measurements. Temperature information given on probes relates only to the measuring range of the sensor technology. Do not expose handles and feed lines to temperatures in excess of 70C (158F), unless they are expressly authorized for use at higher temperatures. Do not perform any contact measurements on uninsulated, live parts. Do not store the product together with solvents. Do not use any desiccants. Only perform maintenance and repair work on this instrument that is described in the documentation. Follow the prescribed steps exactly. Use only original spare parts from Testo. Pos: 12 /BAL/0970 2603 testo Saveris Restaurant Datenlogger BAL/01 Sicherheit _6.docx
@ 248715 @ @ 1 Batteries Improper use of batteries may cause the batteries to be destroyed, or lead to injury due to current surges, fire or escaping chemicals. Only use the batteries supplied in accordance with the instructions in the instruction manual. Do not short-circuit the batteries. Do not take the batteries apart and do not modify them. Do not expose the batteries to heavy impacts, water, fire or temperatures in excess of 60 C. Do not store the batteries in the proximity of metal objects. In the event of contact with battery acid: rinse affected areas thoroughly with water, and if necessary consult a doctor. Do not use any leaky or damaged batteries. Only charge the rechargeable battery in the instrument or in the recommended charging station. Immediately stop the charging process if this is not completed in the given time. Take the rechargeable battery out of the instrument or the charging station immediately if it is not functioning properly or if it shows signs of overheating. Rechargeable battery may be hot!
When not in use for a long period of time, take the rechargeable battery out of the instrument to prevent exhaustive discharge. Pos: 13 /BAL/0970 2603 testo Saveris Restaurant Datenlogger BAL/01 Sicherheit und Entsorgung/01_02 Sicherheit/2 Warnhinweise @ 20\mod_1476692786925_6.docx @ 248787 @ 2 @ 1 Removal Dispose of faulty rechargeable batteries/spent batteries in accordance with the valid Pos: 16 /BAL/0970 2603 testo Saveris Restaurant Datenlogger BAL/01 Sicherheit und Entsorgung/01_03 Entsorgung/Entsorgung @ 20\mod_1476694686141_6.docx @ 248859 @ @ 1 legal specifications. At the end of its useful life, send the product to the separate collection for electric and electronic devices (observe local regulations) or return the product to Testo for disposal. 2 Technische Daten / Technical data Pos: 18 /BAL/0970 2603 testo Saveris Restaurant Datenlogger BAL/02 Technische Daten/02_00 Technische Daten/Messspezifische Daten @ 20\mod_1476695060700_6.docx @ 248965 @ @ 1 Messspezifische Daten / Measurement-specific data NTC external 0572 2621 0572 2620 NTC intern
-30...+50 C WLAN data logger Sensor type Measuring range Accuracy 1 digit Resolution Funkspezifische Daten / WLAN-specific data 0,5 C 0,5 C 0,1 C 0,1 C 0572 2622 0572 2623 NTC external Air: -30...+80 C NTC external Dummy: -30+50 C 0,5 C 0,5 C 0,1 C 0,1 C 0572 2620 0572 2621 0572 2622 0572 2623 WLAN data logger Radio frequency Encryption method Allgemeine Daten / General data 2,4 GHz WPA/WPA2 Personnel, WPA2 Enterprise, WEP WLAN data logger 0572 2620 0572 2621 0572 2622 0572 2623 WLAN data logger Operating temperature
(with Energizer L91 Lithium batteries) Storage temperature
(excluding batteries) Protection class Measuring cycle Communication rate Memory Battery life Voltage supply Dimensions in mm Weight
(including batteries) EN 12830-
compliant Reg. 1935 /
2004-compliant Door contact Wall bracket Cable length 95 g x x x x x x x x x 0572 2620 0572 2621 0572 2622 0572 2623
-30...+50 C
-30...+70 C IP65 5 s to 24 h 1 min to 24 h 10.000 readings 10.000 readings per channel At 20 C, 15-minute measuring cycle and 240-minute communication 2 years rate 3 x AAA 79.6 x 53 x 23.5 83.15 x 53 x 23.5 111 g 83.15 x 53 x 23.5 167 g 83.15 x 53 x 23.5 179 g
-S, T, A, C, D, 1 Air : 2.0 m Product t: 2.0 m Air : 2.0 m Product t: 2.0 m Air : 2.0 m Product t: 2.0 m Door: 1.0 m Internal sensor External sensor x x x x 3 Zulassungen / Authorizations Pos: 27 /BAL/0970 2603 testo Saveris Restaurant Datenlogger BAL/11 Zulassungen und Zertifizierung/Zulassungen @ 20\mod_1476697645741_6.docx @ 249105 @ @ 1 The use of the wireless module is subject to the regulations and stipulations of the respective country of use, and the module may only be used in countries for which a country certification has been granted. The user and every owner has the obligation to adhere to these regulations and prerequisites for use, and acknowledges that the re-sale, export, import etc. in particular in countries without wireless permits, is his responsibility. WLAN-Module / WLAN module Feature WLAN Range WLAN type WLAN radio class Company Values 100 m LSD4WF0459-01D0 Accord with the standard of IEEE 802.11b/g/n Lierda Technology Group co., LTD EU countries:
Belgium (BE), Bulgaria (BG), Denmark (DK), Germany (DE), Estonia (EE), Finland (FI), France (FR), Greece (GR), Ireland (IE), Italy (IT), Latvia (LV), Lithuania (LT), Luxembourg
(LU), Malta (MT), Netherlands (NL), Austria (AT), Poland (PL), Portugal (PT), Romania
(RO), Sweden (SE), Slovakia (SK), Slovenia (SI), Spain (ES), Czech Republic (CZ), Hungary (HU), United Kingdom (GB), Republic of Cyprus (CY). EFTA countries:
Iceland, Liechtenstein, Norway, Switzerland The EU Declaration of Conformity can be found on the testo homepage www.testo.com under the product specific downloads. Kanada Contains IC: 21461-LSD4WF0459 IC: 6127B-0572262X USA Contains FCC ID: N8NLSD4WF0459 FCC ID: WAF-0572262X IC Warnings RSS-Gen & RSS-247 statement:
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. Federal Communication Commission (FCC) Radiation Exposure Statement When using the product, maintain a distance of 20cm from the body to ensure compliance with RF exposure requirements. FCC warning statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Connect the equipment into an outlet on a circuit different from that to which the Increase the separation between the equipment and receiver. receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Caution Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Shielded interface cable must be used in order to comply with the emission limits. Warning This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, 0970 0603 de-en 01e