Originator C. Bohren
TI PROPRIETARY T E X A S I N S T R U M E N T S INFORMATION -
INTERNAL DATA R F I D SYSTEMS S P E C I F I C A T I O N Subco/Mfg Spec. User Guide Test Control Software S4110 MFR Evaluation Kit PRINTED COPIES OF THIS SPECIFICATION ARE NOT CONTROLLED DOCUMENTS. VERIFY THEIR CORRECT REVISION BEFORE USE. 00 Revision:
User Guide Test Control Software S4110 MFR Evaluation Kit Page 1 of 15 XX-XX-XX-XXX PAGE TI PROPRIETARY INFORMATION -
INTERNAL DATA T E X A S I N S T R U M E N T S R F I D SYSTEMS S P E C I F I C A T I O N Revision:
00 4. 4.2 4.1 4.2.1 4.1.1 3.2.1 3.1 3.2 2.1 2.2 3.3 3.4 3.5 3.6 3.7 3.8 TABLE OF CONTENTS 1. Purpose..............................................................................................................3 2. Hardware Set up...............................................................................................3 S4110 MFR Evaluation Kit Hardware supplied...........................................3 Hardware Set Up.........................................................................................4 3. Test Software ....................................................................................................5 Initial Start Screen ......................................................................................5 Connection to RS232 Communications (Com) Port.....................................5 Communications Port Choices.............................................................5 Turn On HF Transmitter .............................................................................6 Turn On LF Transmitter..............................................................................8 Turn Off HF Transmitter...........................................................................10 Turn Off LF Transmitter ...........................................................................11 Close Com Port.........................................................................................12 Close Application .....................................................................................13 Installation Guide S4110R MFR Evaluation Kits as shipped from factory .13 Box Unit S4110 MFR Evaluation Kit as shipped from factory ..................14 Placement of FCC Label on Box Unit ...............................................14 SDK Unit S4110 MFR Evaluation Kit as shipped from factory .................14 Placement of FCC Label on Box Unit ...............................................14 5. Revision History..............................................................................................15 LIST OF FIGURES Figure 1: Back Panel MFR Evaluation Kit Black Box Reader.............................. 3 Figure 2: Software Development Kit (SDK)........................................................... 3 Figure 3: Globtek Power Supply Model Number: GT-21089-1509-T3................. 4 Figure 4: Hardware Set Up MFR Evaluation Kit.................................................. 4 Figure 5: Initial Start Screen .................................................................................. 5 Figure 6: Com Port Choices supported .................................................................. 6 Figure 7: Successful Com Port Connection........................................................ 7 Figure 8: Turn On HF Transmitter........................................................................ 7 Figure 9: Successful "Turn On " of HF Transmitter ............................................ 8 Figure 10: Turn On LF Transmitter ...................................................................... 9 Figure 11: Successful Turn On of LF Transmitter ............................................ 9 Figure 12: Turn Off HF Transmitter ....................................................................10 Figure 13: Turn Off LF Transmitter....................................................................11 Figure 14: Com Port Closure.................................................................................12 Figure 15: Successful Com Port Closure...............................................................13 Figure 16: FCC Label for S4110R MFR Evaluation Kit ......................................13 Figure 17: Placement of FCC Label on S4110R Evaluation Kit Box Unit...........14 Figure 18: Placement of FCC Label on S4110R Evaluation Kit SDK Unit .........14 User Guide Test Control Software S4110 MFR Evaluation Kit Page 2 of 15 Printed copies are not controlled documents - verify the correct revision before use. XX-XX-XX-XXX TI PROPRIETARY INFORMATION -
INTERNAL DATA 1. Purpose T E X A S I N S T R U M E N T S R F I D SYSTEMS S P E C I F I C A T I O N Revision:
00 The purpose of this document is to demonstrate the Test Control software for the S4110 MFR Evaluation Kit.. 2. Hardware Set up 2.1 S4110 MFR Evaluation Kit Hardware supplied 1) S4110 MFR Evaluation Kit Black Box Reader 2) S4110 MFR Evaluation Kit Software Development Kit (SDK) Reader 3) Power Supply, 9.0 Vdc 1.0 A, Globtek Part Number: TR9CD1700LCP-Y Globtek Model Number: GT-21089-1509-T3 RS485 Connector RS232 Connector DC Power connector
+9 Vdc is center pin Figure 1: Back Panel MFR Evaluation Kit Black Box Reader Figure 2: Software Development Kit (SDK) User Guide Test Control Software S4110 MFR Evaluation Kit Page 3 of 15 XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. TI PROPRIETARY INFORMATION -
INTERNAL DATA T E X A S I N S T R U M E N T S R F I D SYSTEMS S P E C I F I C A T I O N Revision:
00 Figure 3: Globtek Power Supply Model Number: GT-21089-1509-T3 Globtek Part Number: TR9CD1700CP-Y 2.2 Hardware Set Up PC Com 1 Serial RS232 Port Communications board Connector J232 RS232 RS232 S4100 MFR Lite PC with MFR Eval Kit Test Software Connector, DB9M No Connection J485 RS485 RS485
+9 Volts DC Power HF/LF Antenna Board MFR Evaluation Kit D = Distance form Tag to Reader "D
TAG Power Supply 9V DC 1.0 Amp Globtek PN: TR9CD1700CP-Y Model Number: GT-21089-1509-
T3 J12 Power Connector Circular DIN Figure 4: Hardware Set Up MFR Evaluation Kit User Guide Test Control Software S4110 MFR Evaluation Kit Page 4 of 15 XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. TI PROPRIETARY INFORMATION -
INTERNAL DATA 3. Test Software T E X A S I N S T R U M E N T S R F I D SYSTEMS S P E C I F I C A T I O N Revision:
00 Initial Start Screen 1) After double clicking the MFR Demo software icon the software screen below will appear. 2) Double click desired application folder tab to select application. 3.1 Selects desired Com port Press to Open Com Port When Status Box is Green Com port is open Figure 5: Initial Start Screen 3.2 Connection to RS232 Communications (Com) Port 1) Click on Connect button to open the COM port. Youll see the red indicator box with COM Closed text change color to GREEN and read COM Opened for successful connection. 2) If red indicator box stays red and reads Com Closed, the COM port did not open successfully. 3.2.1 Communications Port Choices 1) If the default Com Port of Com1 is not the desired Com Port, use Com Port selection arrow to select desired Com Port; from the following choices 1) Com1, 2) Com2, 3) Com3, 4) Com4. User Guide Test Control Software S4110 MFR Evaluation Kit Page 5 of 15 XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. TI PROPRIETARY INFORMATION -
INTERNAL DATA T E X A S I N S T R U M E N T S R F I D SYSTEMS S P E C I F I C A T I O N Revision:
00 2) Click on Connect button to open the COM port. Youll see the red indicator box with COM Closed text change color to GREEN and read COM Opened for successful connection. 3) If red indicator box stays red and reads Com Closed, the COM port did not open successfully. Use Com Port Select Arrow to select desired Com Port Figure 6: Com Port Choices supported 3.3 Turn On HF Transmitter To Turn on the HF Transmitter:
1) Select 14443A Library folder Tab 2) Under 14443A Library folder Tab select Transmitter On 3) Click on Execute button to issue a HF- Transmitter ON Command. 4) If successful, you would see the Green indicator with TRANSMITTER ON 14443A text. User Guide Test Control Software S4110 MFR Evaluation Kit Page 6 of 15 XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. TI PROPRIETARY INFORMATION -
INTERNAL DATA T E X A S I N S T R U M E N T S R F I D SYSTEMS S P E C I F I C A T I O N Revision:
00 Figure 7: Successful Com Port Connection Select Folder for 14443-A Library to start HF transmitter turn on procedure When Status Box is Green Com port is open HF Transmitter On Folder Tab Press to turn on HF (13.56 MHz) Transmitter Figure 8: Turn On HF Transmitter User Guide Test Control Software S4110 MFR Evaluation Kit Page 7 of 15 XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. TI PROPRIETARY INFORMATION -
INTERNAL DATA T E X A S I N S T R U M E N T S R F I D SYSTEMS S P E C I F I C A T I O N Revision:
00 Select Folder for LF-DST Library to start LF transmitter turn on procedure HF (13.56 MHz) Transmitter On Figure 9: Successful "Turn On " of HF Transmitter 3.4 Turn On LF Transmitter To Turn on the LF Transmitter:
1) Select LF-DST Library folder Tab 2) Under LF-DST Library folder Tab select Transmitter On 3) Click on Execute button to issue a LF- Transmitter ON Command. 4) If successful, you would see the Green indicator with TRANSMITTER ON LF-DST text. User Guide Test Control Software S4110 MFR Evaluation Kit Page 8 of 15 XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. TI PROPRIETARY INFORMATION -
INTERNAL DATA T E X A S I N S T R U M E N T S R F I D SYSTEMS S P E C I F I C A T I O N Figure 10: Turn On LF Transmitter Revision:
00 Select Folder for LF-DST Library to start LF transmitter turn on procedure LF Transmitter On Folder Tab Press to turn on LF (134 kHz) Transmitter LF (134 kHz) Transmitter On XX-XX-XX-XXX Figure 11: Successful Turn On of LF Transmitter User Guide Test Control Software S4110 MFR Evaluation Kit Page 9 of 15 Printed copies are not controlled documents - verify the correct revision before use. TI PROPRIETARY INFORMATION -
INTERNAL DATA T E X A S I N S T R U M E N T S R F I D SYSTEMS S P E C I F I C A T I O N Revision:
00 1) Select 14443A Library folder Tab 2) Under 14443A Library folder Tab select Transmitter Off 3) Click on Execute button to issue a HF- Transmitter Off Command. 4) If successful, you would see the Green indicator with TRANSMITTER 3.5 Turn Off HF Transmitter To Turn Off the HF Transmitter:
OFF 14443A text. HF Transmitter Off Folder Tab Select Folder for 14443-A Library to start HF transmitter turn off procedure Press to turn off HF
(13.56 MHz) Transmitter Page 10 of 15 XX-XX-XX-XXX Figure 12: Turn Off HF Transmitter User Guide Test Control Software S4110 MFR Evaluation Kit Printed copies are not controlled documents - verify the correct revision before use. TI PROPRIETARY INFORMATION -
INTERNAL DATA T E X A S I N S T R U M E N T S R F I D SYSTEMS S P E C I F I C A T I O N Revision:
00 3.6 Turn Off LF Transmitter To Turn off the LF Transmitter:
1) Select LF-DST Library folder Tab 2) Under LF-DST Library folder Tab select Transmitter OFF 3) Click on Execute button to issue a LF- Transmitter OFF Command. 4) If successful, you would see the Green indicator with TRANSMITTER OFF LF-DST text. LF Transmitter Off Folder Tab Select Folder for LF-DST Library to start LF transmitter turn off procedure Figure 13: Turn Off LF Transmitter User Guide Test Control Software S4110 MFR Evaluation Kit Page 11 of 15 XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. TI PROPRIETARY INFORMATION -
INTERNAL DATA 3.7 Close Com Port T E X A S I N S T R U M E N T S R F I D SYSTEMS S P E C I F I C A T I O N Revision:
00 1) Close the COM port by clicking on Disconnect button. 2) You will see the Green Status Indicator with COM Open text, change color to RED with a text change to Com Closed to indicate successful closure of the COM port. Press Disconnect Button to Close Com Port Figure 14: Com Port Closure User Guide Test Control Software S4110 MFR Evaluation Kit Page 12 of 15 XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. TI PROPRIETARY INFORMATION -
INTERNAL DATA T E X A S I N S T R U M E N T S R F I D SYSTEMS S P E C I F I C A T I O N Revision:
00 Figure 15: Successful Com Port Closure 3.8 Close Application 1) Click EXIT button to close the application. 4. Installation Guide S4110R MFR Evaluation Kits as shipped from factory The Box unit and SDK unit configurations of the S4110 MFR Evaluation Kit as shipped from the factory are compliant with FCC Part 15 Rules. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference FCC ID: A92S4110R Made in USA that may cause undesired operation. Figure 16: FCC Label for S4110R MFR Evaluation Kit User Guide Test Control Software S4110 MFR Evaluation Kit Page 13 of 15 XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. TI PROPRIETARY INFORMATION -
INTERNAL DATA T E X A S I N S T R U M E N T S R F I D SYSTEMS S P E C I F I C A T I O N 4.1 Box Unit S4110 MFR Evaluation Kit as shipped from factory Revision:
00 4.1.1 Placement of FCC Label on Box Unit Figure 17: Placement of FCC Label on S4110R Evaluation Kit Box Unit 4.2 SDK Unit S4110 MFR Evaluation Kit as shipped from factory 4.2.1 Placement of FCC Label on Box Unit Figure 18: Placement of FCC Label on S4110R Evaluation Kit SDK Unit User Guide Test Control Software S4110 MFR Evaluation Kit Page 14 of 15 XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use. TI PROPRIETARY INFORMATION -
INTERNAL DATA T E X A S I N S T R U M E N T S R F I D SYSTEMS S P E C I F I C A T I O N Revision:
00 NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help. 5. Revision History Rev. SCN Description of Change 0 New Issue User Guide Test Control Software S4110 MFR Evaluation Kit Date submitted By 04/20/2004 C.Bohren Page 15 of 15 XX-XX-XX-XXX Printed copies are not controlled documents - verify the correct revision before use.