Exhibit D Users Manual per 2 1033 b3 | Users Manual | 4.94 MiB | ||||
1 | Cover Letter(s) | |||||||
1 | ID Label/Location Info | |||||||
1 |
|
Exhibit C External Photographs per 2 1033 b7 | External Photos | 767.76 KiB | ||||
1 |
|
Exhibit C Internal Photographs per 2 1033 b7 | Internal Photos | 1.98 MiB | ||||
1 | Test Setup Photos | |||||||
1 | Test Report |
1 | Exhibit D Users Manual per 2 1033 b3 | Users Manual | 4.94 MiB |
RESIDENTIAL WALL MOUNT OPENER INSTALLATION, PROGRAMMING, OPERATION, TROUBLESHOOTING & MAINTENANCE MANUAL DO NOT use photocells from other manufacturers or openers with this opener. INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER HOMEOWNER: SAVE THIS MANUAL FOR FUTURE REFERENCE
!
WARNING To reduce the risk of injury to persons or damage to property, use this opener only with a residential sectional door with front torsion springs. RETRANSLATE Por reduire le risque de blessures ou de dommages materials, utillsez cet ouvre-porte uniquement pour une porte a section re sidentielie. AVERTISSEMENT
!
SERIAL NUMBER DECAL iDCM SERIAL NUMBER DECAL 39947503927, 06/2019 INDEX Information Page Standard & Safety Features:
.................................................................................................................1 Section 1 2 3 4 5 6 7 8 9 10 Safety & General Information:
Introduction .......................................................................................2 Safety Notifications ..........................................................................2 Important Installation Instructions ............................................3 Opener Installation:
Pre-Installation Measures ..............................................................4 Pre-Installation Permanent Input Wiring .................................5 Installing Cable Keepers ................................................................6 Installing Opener ..........................................................................7-9 Installing Door Lock .......................................................................10 Install and Wire Opener and Accessories:
Wire Door Lock ................................................................................11 Install and Wire Safe-T-Beam ....................................................12 Install Wireless Wall Console .......................................................13 Install LED Light System ...............................................................13 Install and Wire Optional Wired Wall Console ......................14 Install and Wire Optional External Interlock .........................14 Install Bottom Cover ......................................................................14 Apply Power to Opener ................................................................15 Programming Opener and Accessories:
Introduction .....................................................................................16 Setting Down Limit ........................................................................17 Setting Up Limit ..............................................................................18 Setting Force Control and Contact Reverse ..........................19 Programming additional Remote Controls ...........................20 Programming Accessories:
Wireless Keypad* ............................................................................21 Programming Vehicle Controls* ........................................22-23 Programming Aladdin Connect .......................................24-25 Special Installation Information:
Clearing Remote/Accessory Memory .....................................26 Locating Safe-T-Beam Pairs ......................................................27 Safe-T-Beam Troubleshooting .................................................27 Changing Drum Size Setting (speed) ......................................28 Changing Force Settings .............................................................29 Installing the Battery Back up ....................................................30 Adding and programming Bluetooth accessories ...........31 Maintenance:
Important Safety Instructions ....................................................32 Regular Maintenance Schedule ................................................33 Door Inspection & Maintenance ...............................................33 Remote Battery Replacement ....................................................33 Troubleshooting & Led Signals ......................................34-36 Replacement Parts ...............................................................37-39 Dasma Information ..............................................................40-41 SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS Scan this code for a video of this installation or visit: www.geniecompany.com
* Abbreviated versions. See instructions that accompany Accessory or Vehicle owners manual for full details, WARNINGS, CAUTIONS and instructions. FCC Part 15.21 Statement:
Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. FCC / IC Statement:
This device complies with FCC Part 15 and Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes : (1) lappareil ne doit pas produire de brouillage, et (2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. 1 STANDARD AND SAFETY FEATURES 6 7 5 3 1 Vehicle Compatible 4 2 1. Safe-T-Beam (STB) Non-Contact Reversing System:
Places an infrared beam across the door opening. Only affects the DOWN travel of the door. Stops an open door from closing or reverses a door while in the down travel. Reversing system can be overridden with constant pressure on the wired wall console only. The door will stop and reverse to the full open position if beam is obstructed. Self-diagnostic LEDs on STBs and Powerhead alert to operational issues (See Locating Safe-T-Beam Pairs & Troubleshooting section in this manual for more information). 2. Contact Reversing System:
Force control automatically reverses a closing door upon contact with an obstruction. 3. Manual Emergency Release pull handle & cord:
of the door. Manually releases door from door opener. Used during a power failure or other emergency to allow manual opening and closing 4. Automatic Bluetooth Lighting System:
Lighting system turns ON when door is activated and automatically turns OFF 4 minutes later. Can be activated/deactivated manually from the wall console. 5. Integrated Aladdin Connect (iDCM):
Aladdin Connect. Available with select models, allows operation of the garage door opener with a secure mobile device application (app) from 6. Wireless Wall Console:
Wireless Wall Console operates door opener from inside garage with an open/close button. Manual light control and override. OPEN/CLOSE Delay button. Ads an operation delay. Press once for 10 seconds, twice for 20 seconds, three times for 30 seconds. 7. Intellicode Encryption, Factory Programmed Remote(s) :
An encryption system that enhances the security of the door opener by continuously changing the access code each time the remote is used. Factory programmed remote control(s) included with this opener. Not Shown- Battery Backup (Included on select models) :
Mounts to bottom of opener and provides power for opener operation during power outages. 1 2 SAFETY NOTIFICATIONS & INSTRUCTIONS OVERVIEW OF POTENTIAL HAZARDS READ THIS SAFETY INFORMATION Garage doors are large, heavy objects that move with the help of springs under high tension and electric motors. Since moving objects, springs under tension, and electric motors can cause injuries, your safety and the safety of others depend on you reading the information in this manual. If you have questions or do not understand the information presented, call your nearest trained door system technician or visit our website at www.geniecompany.com CONVENTIONS USED IN THESE INSTRUCTIONS The following safety alert symbol and signal words are used throughout this manual to call attention to and identify different levels of hazards and special instructions. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and the word DANGER, WARNING, or CAUTION. DANGER indicates an imminently hazardous situation which, if NOT avoided, will result in death or serious injury. WARNING indicates a potentially hazardous situation which, if NOT avoided, could result in death or serious injury. CAUTION indicates a potentially hazardous situation which, if NOT avoided, may result in injury or property damage. The word NOTE is used to indicate important steps to be followed or important considerations. Tous les messages concernant la scurit seront indiqus aprs un symbole dalerte de la scurit et lune des mentions suivantes DANGER, AVERTISSEMENT ou MISE EN GARDE. DANGER signale une situation dangereuse imminente qui, si elle nest pas vite, risque dentraner des blessures graves, voire mortelles. AVERTISSEMENT signale une situation potentiellement dangereuse qui, si elle nest pas vite, risque dentraner la mort ou des blessures graves. MISE EN GARDE signale une situation potentiellement dangereuse qui, si elle nest pas vite, risque dentraner des blessures ou des dommages matriels. Le terme REMARQUE est utilis pour signaler les tapes importantes suivre ou dimportants lments prendre en considration. IMPORTANT SAFETY INSTRUCTIONS POTENTIAL HAZARD EFFECT PREVENTION MOVING DOOR
!
WARNING Could result in Serious Injury of Death ELECTRICAL SHOCK HIGH SPRING TENSION WARNING
!
Could cause Serious Injury or Death WARNING
!
Could cause Serious Injury or Death Do Not operate unless the doorway is in sight and free of obstructions. Keep people clear of opening while door is moving. Do Not allow children to play with the door opener. Do Not change opener control to momentary contact unless an external reversing means is installed. Do Not operate a door that jambs or one that has a broken spring. Turn off electrical power before removing opener cover. When replacing the cover, make sure wires are not pinched or near moving parts. Opener must be electrically grounded. Do Not try to remove, repair or adjust springs or anything to which door spring parts are fastened such as wood block, steel brackets, cables or any other structure or like item. Repairs and adjustments must be made by a trained service representative using proper tools and instructions. IMPORTANTES CONSIGNES DE SCURIT DANGER POTENTIEL EFFET PRVENTION PORTE EN MOUVEMENT
!
AVERTISSEMENT Pourrait entraner des blessures graves voire la mort CHOC LECTRIQUE
!
AVERTISSEMENT Pourrait entraner des blessures graves voire la mort Utiliser uniquement si la porte est en vue et libre de tout obstacle. Ne laisser personne se tenir dans louverture de la porte pendant quelle est en mouvement. Ne pas permettre aux enfants de jouer avec loprateur de la porte. Ne pas modifier la commande de loprateur contact momentan moins quun moyen dinversion externe soit install. Ne pas faire fonctionner une porte qui bloque ou dont le ressort est cass. Couper le courant avant denlever le couvercle de loprateur. Lorsque le couvercle doit tre remplac, sassurer que les fils ne sont ni coincs ni prs des pices mobiles. Loprateur doit tre correctement mis la terre. TENSION LEVE RESSORT 2
!
AVERTISSEMENT Pourrait entraner des blessures graves voire la mort Ne pas essayer denlever, rparer ni ajuster les ressorts ou toute autre pice laquelle le ressort de la porte est attach, y compris blocs de bois, supports en acier, cbles ou autres articles semblables. Les rparations et les rglages doivent tre effectus par technicien qualifi qui se sert doutils appropris et qui respecte les instructions. IMPORTANT INSTALLATION INSTRUCTIONS
!
WARNING TO REDUCE THE RISK OF SEVERE INJURY OR DEATH READ AND FOLLOW ALL SAFETY, INSTALLATION AND OPERATION INSTRUCTIONS. If you have any questions or do not understand an instruction, call The Genie Company. READ AND FOLLOW ALL SAFETY, INSTALLATION AND OPERATION INSTRUCTIONS. If you have any questions or do not understand an instruction, call The Genie Company. DO NOT install opener on an improperly balanced door. An improperly balanced door could cause severe injury. Repairs and adjustments to cables, spring assembly and other hardware must be made by a trained service person using proper tools and instructions. Remove all ropes, and disable all locks connected to the door before installing opener. Where possible, install the door opener 7 feet or more above the floor. For products having an emergency release, mount the emergency release within reach, but at least 6 feet above the floor and avoiding contact with vehicles to avoid accidental release. DO NOT use emergency release cord to pull door. DO NOT connect the opener to the source of power until instructed to do so. Locate the control button: (a) within sight of the door, (b) at a minimum height of 1.53 m (5 ft) above floors, landings, steps or any other adjacent walking surface so small children are not able to reach it, and (c) away from all moving parts of the door. Install the entrapment WARNING label next to the wall button or console, in a prominent location. Install the emergency release handle on the emergency release cord. The opener must reverse when the door contacts a 1-1/2 inch high object on the floor at the center of the doorway. This is about the size of a 2 x 4 board laid flat. IMPORTANTES INSTRUCTIONS DINSTALLATION
!
AVERTISSEMENT POUR RDUIRE LES RISQUES DE BLESSURES GRAVES VOIRE MORTELLES LIRE ET SUIVRE ATTENTIVEMENT TOUTES LES INSTRUCTIONS DINSTALLATION ET DE FONCTIONNEMENT AINSI QUE TOUTES LES CONSIGNES DE SCURIT. Si vous avez des questions ou si vous ne comprenez pas une instruction, veuillez contacter directement The Genie Company. NE PAS installer loprateur sur une porte mal quilibre. Celle-ci pourrait entraner de graves blessures. Les rparations et les rglages des cbles, ensembles de ressort ou tout autre article de quincaillerie doivent tre effectus par un professionnel qui se sert doutils appropris et qui respecte les instructions. Enlever toutes les cordes et dsactiver toutes les verrous de la porte avant linstaller loprateur. Dans la mesure du possible, installer louvre-porte 2,1 m ou plus au-dessus du sol. Pour les produits dots dun cordon de dclenchement durgence, installer le dclenchement durgence mais au moins 1,8 m au-dessus du sol en vitant tout contact avec les vhicules pour viter quils ne soient dclenchs accidentellement. NE PAS utiliser durgence cordon de libration pour ouvrir ou fermer la porte. NE PAS connecter loprateur la source dalimentation tant que linstruction nest pas donne. Installez le bouton de commande a) un endroit que lon peut voir de lembrasure de la porte; b) une hauteur minimale de 1,53 m (5 pi) du sol afin que les jeunes enfants ne puissent pas latteindre ; et c) lcart des Pices mobiles de la porte. Placer ltiquette dAVERTISSEMENT en cas de coinage proximit du bouton mural ou de la console de manire ce quelle soit bien en vidence. Installer la poigne du cordon de dclenchement durgence. Loprateur doit sinverser lorsque la porte entre en contact avec un objet dune hauteur de 3,8 cm plac sur le sol, au centre de louverture de la porte. Ceci quivaut environ une planche de 5 x 10 cm pose plat sur le sol.
!
WARNING Opener is equipped with grounded electrical plug for your protection, and only fits grounded electrical outlets. DO NOT alter plug in any way! If your have no grounded outlets, have one installed by a licensed electrician. Opener must be properly grounded to prevent personal injury and equipment damage. NEVER USE AN EXTENSION CORD! Check local building codes for any requirement that you must have a permanent hard-wired connection. Permanent hard-wired connections must be performed by a licensed electrician using proper tools and instructions.
!
AVERTISSEMENT Loprateur, qui est quip dune prise lectrique mise la terre pour votre protection est compatible uniquement avec des prises lectriques mises la terre. NE PAS modifier la fiche dune quelconque manire. Si vous navez pas de prises mises la terre, faites-en installer par un lectricien agr. Loprateur doit tre correctement mis la terre pour viter les blessures corporelles et des dommages matriels. NE JAMAIS UTILISER DE RALLONGE!
Vrifiez les codes locaux des btiments pour connexions cbles permanente. Les connexions cbles permanentes doivent tre effectues par un lectricien agr qui se servira doutils appropris et respectera les consignes. 3 3 Compatibility Considerations:
The Genie Residential Wall Mount opener is intended for use on:
PRE-INSTALLATION MEASURES Standard lift up to 14 feet tall, using industry standard APCO 400.8 , 400.12 and 5250.18 drums. Hi-lift sectional doors up to 14 feet tall and 84 inches maximum of high lift using industry standard APCO 400.54 , 5250.54 and 500.84 drums. Vertical lift doors up to 14 feet tall, using industry standard APCO 850.11 and 1100.18 drums. Doors up to 18 feet wide not to exceed 180 square feet and 850 lbs. balance weight. Only doors that use torsion springs with a torsion bar diameter of 1 in. solid or hollow 14 or 16 ga. tubular steel. Not compatible with low headroom outside hook-up, i.e. reverse wound drums.
!
WARNING Garage door hardware (springs, cables, brackets, pulleys, etc.) are under extreme pressure and tension. DO NOT attempt to repair or adjust door springs or any hardware, and DO NOT OPERATE garage door automatically or manually if door is improperly balanced or springs are broken. CONTACT A TRAINED DOOR SYSTEM TECHNICIAN.
!
AVERTISSEMENT La quincaillerie de la porte de garage (ressorts, cbles, supports, poulies, etc.) sont sous des pressions et des tensions extrmes. NE PAS rparer ni rgler les ressorts de la porte ou toute autre pice de quincaillerie et NE PAS ACTIONNER la porte manuellement ou automatiquement si elle nest pas correctement quilibre ou si des ressorts sont casss. CONTACTEZ UN TECHNICIEN SPCIALIS EN SYSTME DE PORTES Door Inspection:
If the intended door meets the above requirements, inspect the door for proper balance and general condition. Raise and lower the door manually. Door should move freely and smoothly. Raise door manually about 3 to 4 feet from floor and let go. Door should remain stationary or slowly drift closed. FIG.A. If door opens or closes rapidly, CONTACT A TRAINED DOOR SYSTEM TECHNICIAN to have your door springs serviced. Disable or remove all locks and ropes attached to the door. Monitor the end of the torsion bar while the door is raised and lowered. It is important that there is no noticeable movement up and down or side to side. Repair if necessary, other wise opener reliability will be significantly reduced. FIG. A Critical Measurements:
This opener can be installed left or right handed. Critical measurements must be taken to ensure this opener will fit the intended door. This opener will only fit onto torsion shafts, solid or tubular, of 1 inch in diameter with or without a keyway. (X) Measure the distance between the torsion bar centerline to the wall. This dimension must be between 2-1/2 and 6. (A) The torsion bar shaft must protrude no less than 2-1/4 from bearing plate. (B) A standard 115 VAC grounded electrical outlet will be required within 6 feet of the bottom of the opener. Torsion bar centerline to the ceiling must be at least 2-1/4 for clearance. (C) Note: Headroom required is less than smallest standard drum. End of torsion shaft to side wall clearance must be at least 7 in. for clearance (D) B C D A X 4 SIDE VIEW FRONT VIEW PRE-INSTALLATION MEASURES (PERMANENT WIRING) If a 115V power outlet is not available within 5 feet of the opener when mounted to door. Permanent wiring or the EXTENDED POWER INPUT KIT may be required. This task should be performed prior to mounting opener. PERMANENT WIRING SHOULD BE COMPLETED BY A TRAINED ELECTRICIAN ONLY:
1. Install opener per instructions on pages 6 through 9. 2. Remove two screws from bottom of cover and remove main opener cover/ circuit board assy. 3. Unplug wire harnesses from main board. 4. Unplug input power cable connector from transformer input. 5. Remove transformer from chassis. 6. Remove strain relief and pull power cable from opener. 7. Cut power cable wires and strip insulation from power cable input harness connector end. All wire connections must be made INSIDE CHASSIS and there must be at least 3 of new power supply line wire inside chassis. Check local code for the use of conduit or other protective material. Conduit, fittings/strain relief, and wire nuts are not provided. 8. Install 1/2in. NPT or other suitable connector into chassis. (Adhere to local electrical code(s) and regulations) 9. Connect permanent power input cable to harness wires using approved connectors or wire nuts (Adhere to local electrical code(s) and regulations) 10. Install ground connector to permanent power cable ground wire. 11. Install ground screw and power cable ground onto chassis. 12. Plug power input harness into transformer harness. 13. Install transformer. 14. Ensure input power cable and connections do not interfere with internal moving components. 15. Plug all harnesses into main control board and install cover assembly. 16. DO NOT APPLY POWER AT THIS TIME. 17. Continue installation starting on page 10. Extended power input wire kits are available. Fully read and understand the instructions that accompany the kit before proceeding. Wire Nut Connections Strain Relief Cable Connector Remove from chassis External power cable 5 INSTALLING CABLE KEEPERS WARNING AVERTISSEMENT
!
!
Operating a door with frayed or broken counterbalance lift cables can result in severe or fatal injury. Contact a qualified door service company to replace frayed or broken cables before installing cable keepers.
!
WARNING Do not attempt to loosen or remove bottom corner brackets. They are under extreme spring tension and can cause severe or fatal injury. La quincaillerie de la porte de garage (ressorts, cbles, supports, poulies, etc.) sont sous des pressions et des tensions extrmes. NE PAS rparer ni rgler les ressorts de la porte ou toute autre pice de TRANSLATE quincaillerie et NE PAS ACTIONNER la porte manuellement ou automatiquement si elle nest pas correctement quilibre ou si des ressorts sont casss. CONTACTEZ UN TECHNICIEN SPCIALIS EN SYSTME DE PORTES
!
AVERTISSEMENT La quincaillerie de la porte de garage (ressorts, cbles, supports, poulies, etc.) sont sous des pressions et des tensions extrmes. NE PAS rparer ni rgler les ressorts de la porte ou toute autre pice de quincaillerie et NE PAS ACTIONNER la porte manuellement ou automatiquement si elle nest pas correctement quilibre ou si des ressorts sont casss. TRANSLATE CONTACTEZ UN TECHNICIEN SPCIALIS EN SYSTME DE PORTES 1. Carefully inspect the counterbalance lift cables on the door. If they are worn, frayed or broken, contact a qualified door service company to replace the counterbalance lift cables before installing the cable keepers. 2. Push spacer onto the shaft between the short stem track roller and the bottom corner bracket. Use an additional spacer if 3. needed to achieve a minimum of 1/2 clearance. If there is less than 1/2 clearance, loosen the lag screws attaching the track to the wall and adjust the track for the 1/2 clearance. Re-tighten the lag screws. 4. Position the right hand (black) cable keeper assembly directly above the garage door bottom corner bracket. 5. The cable keeper assembly must extend 1/8 past the end of the door section. Ensure there is no more than 4-1/2 from the bottom edge of the door to bottom of cable keeper. IMPORTANT: RIGHT AND LEFT HAND IS ALWAYS DETERMINED FROM INSIDE THE BUILDING LOOKING OUT. 6. 7. Fasten the cable keeper assemblies with (2) 1/4 - 20 x 11/16 self drilling screws (wood doors will use (2) 1/4 x 1 lag screws). Once the cable keeper assemblies are secured to the bottom section, place the plastic sleeve over the counterbalance lift cable and then rotate the cable keeper arm upward and attach it to the plastic sleeve. 8. Repeat the same process for the left hand (Red) cable keeper assembly. NOTE: It is recommended that wood doors be pre-drilled with 1/8 pilot holes prior to fastening. IMPORTANT NOTE: Operate door manually full open to full close and watch keeper to ensure that it does not contact door track. Adjust as necessary. Spacer Shaft Short stem track roller Bottom Corner Bracket 1/8 1/2 Min FLOOR 4-1/2 Max 6 Cable Keeper Assembly
(2) 1/4 -20 x 11/16 Self Drilling Screws Cable Keeper Arm Plastic sleeve Counterbalance lift cable Cable keeper arm Cable keeper assembly installed Counterbalance lift cable Plastic sleeve INSTALLING THE OPENER 1) CLOSE DOOR. 2) Remove bolt and lock washer (A) from powerhead chassis and loosely install mounting bracket from kit bag on desired side of powerhead. (Right Hand mount shown) NOTE: Bracket can be mounted to opener on either side depending on mounting requirements. 3) Slide coupler (1-1/4 end) to opener output shaft until it fully seats. (See Coupler Cross Section detail below) 4) Tighten 3 inner set screws on coupler finger tight against opener output shaft. NOTE: The coupler must be installed onto the opener output shaft until the coupler seats completely to the recess inside coupler. NOTE: Opener MUST be mounted to garage framing material. DO NOT install to particle board or drywall. NOTE: Alternate installation method: If dimension D (page 4) is less than 8, install coupler onto door shaft first. Door Shaft - 1 Opener Output Shaft - 1-1/4 Coupler Cross Section Opener Output Shaft Opener Mounting Bracket A 7/16 SOCKET 7 INSTALLING THE OPENER (CONT) 5) Mount opener to door shaft. If the door shaft is NOT keyed, slide opener assembly onto door shaft and tighten setscrews finger tight. If the door shaft IS keyed, insert provided key into either keyway. Pull emergency release cable at the bottom of the opener to allow free rotation of the output shaft to clock the keyways together. Tighten set screws onto door shaft finger tight. NOTE: The mounting of this opener to the door shaft is designed so the door shaft will slide through the coupler and enter the hollow output shaft of the opener up to 3 -3/8 (there is a stop pin located in the center of the opener output shaft). SOLID OR HOLLOW DOOR SHAFT NO KEY OPENER REMOVED FOR CLARITY RIGHT HAND INSTALL SHOWN SOLID KEYED DOOR SHAFT CABLE DRUM DOOR TORSION SHAFT DOOR Bracket can be mounted to opener on either side depending on mounting requirements. 8 RELEASE CABLE INSTALLING THE OPENER (CONT) 1) Mount opener to wall. Level and square opener. NOTE: Vertical lift openers will not be level. Mark mounting bracket hole position, pre-drill a 3/16 pilot hole and install lag screw and fully tighten. Add 1 full turn to hollow tube or 1/2 turn for solid shaft on each coupler set screw in 1/4 turn increments after contacting door and opener shaft surfaces. DO NOT tighten set screws into an empty keyway. Leave at least a 1/4 gap between coupler and door shaft bearing. Tighten mounting bracket bolt to opener. Pull emergency release cable and manually operate door to inspect for binding. Tie RED emergency release cord to cable loop and tie release handle to cord approximately 5 feet from floor. NOTE: Ensure all COUPLER BOLTS are secured prior to tightening mounting bracket bolt. NOTE: Opener MUST be mounted to garage framing material. DO NOT install to particle board or drywall. The instructions above are provided using standard wood framing and bracing. Additional bracing may be required for this installation. Hardware for masonry or steel construction is not provided. 7/16 WRENCH PRO TIP: Use 3/8 - 8 point socket and ratchet to secure square coupler bolts in tight clearance situations. At least 1/4 Gap Level &
Square Opener 3/16 Bit 7/16 SOCKET 9 INSTALLING THE DOOR LOCK Door lock prevents manual door operation and is key to garage security Door lock should be installed no more than 10 feet away on the opener side of the door if possible. 1. Mount door lock onto door track above a roller on the second or third door panel from the floor. If mounting position does not line up with pre punched door lock bar cutouts as shown below:
Cut template from the back page of the owners manual. Tape template to the door track where the center 7/16 hole is approximately 3 inches above the door roller on the 2nd or 3rd door panel. Drill two 9/32 holes for mounting and one 7/16 hole if using template. De-burr holes if required. 2. Position door lock and install two 1/4 X 9/16 track bolts and nuts. Install track bolt on inside of door track facing outward. Approx. 3 9/32 7/16 Bit 7/16 SOCKET 10 4 Wire Door Lock Plug door lock harness into the LOCK plug on bottom of opener. Insert plug in correct direction (INSET) Run wire down the wall to the DOOR LOCK and secure with supplied wire staples. NOTE that DOOR LOCK WIRE THE OPENER wires are polarity sensitive. Cut off excess wire, strip 1/4 of insulation and attach to bottom connectors on DOOR LOCK. Install WHITE wire to W terminal and STRIPED wire to B/W terminal. ALL WIRE CONNECTIONS LOCATED AT BOTTOM OF OPENER 11 WIRE THE OPENER (CONT) Install and Wire Safe-T-Beams (STB) 1. Position Safe-T-Beam (STB) Transmitter and Receiver on each side of garage door 5"- 6" above floor. Face the lenses towards each other. 2. Mark bracket mounting holes; drill 3/32" pilot holes and secure with 1/4" x 1-1/4" lag screws (provided) into wood. If mounting into concrete or block, other fasteners are required and are available at leading retail stores. 3. Route 2 lengths of supplied wire from powerhead, down to one sensor and along the header and down the side of the door to the other sensor. Secure the wire to the walls using the insulated staples. 4. On the powerhead: Remove 1/4" insulation from both sets of white and striped wire. Twist two white wires together. Using a small flat head screwdriver, press in the orange tab at one STB terminal and insert the wires. Twist the two striped wires together and insert into the other STB terminal. NOTE that STB wires are not polarity sensitive. 5. At each sensor, remove 1/4" insulation from the white and striped wires and secure in each terminal. To powerhead Wall mount Wall mount PHOTOCELL (STB) PHOTOCELL (STB) 6 max 6 max 5 min 5 min above oor above oor Floor mount option Transmitter/Receiver 12 WIRE THE OPENER (CONT) Install Wireless Wall Console 1. Determine mounting location for wireless wall console. 2. Mount console no less than 5 feet from floor to prevent small children 3. Pre-drill 3/32 holes for mounting screws, or 3/16 if using drywall anchors from activating opener.
(supplied) if needed. 4. Install bottom screw leaving a 1/8 gap. 5. Slide console onto screw and down slightly to lock in place. 6. Remove upper battery door and remove protective tab and batteries. 7. Install top screw to secure console to the wall. 8. Install batteries and battery door. 9. Install warning decal in the same area as wireless wall console. Open cover and remove battery tab before programming Drywall Anchors AAA AAA Mounting Screws Lower mounting slot Wall Console Operation 1 2 3 1. DOOR Button - Runs garage door opener. 2. DELAY Button - Adds a 10+ second delay for door operation. Press the delay button and door will automatically operate after set delay. Can be activated up to 3 times for a 10, 20 or 30 second delay. 3. LIGHT Button - Overrides the automatic timed light function of the garage door opener. Install Bluetooth Light System 1. Determine mounting location within 30 feet of opener. 2. Pre-drill 3/32 holes for mounting screws, or 3/16 if using drywall anchors (supplied) if needed. 7-1/2 in. inches apart. 3. Install supplied screws leaving an 1/8 gap for mounting. 4. Route power cord through cutouts in flange and plug light into a standard 115V outlet. Secure excess wire under light housing. 5. Aline Light Kit mounting holes with screws and turn light assembly to lock into place. 6. Light kit is pre-programmed from the factory and will operate any time opener is activated and remain on for 4 minutes or overridden from wireless wall console. 7 - 1 / 2 i n . 13 WIRE THE OPENER (CONT) Install and Wire Basic Wall Console (Hardwired) - Optional 1. Route supplied wire from powerhead to the desired location for the hardwired wall control. Secure wire with insulated staples. 2. On the powerhead: Remove 1/4" insulation from white and striped wire. Using a small flat head screwdriver, press in the orange tab and insert the white wire in terminal 3 and the striped wire in terminal 4. (BWC TERMINALS) 3. At the wall console end of the wire, remove 1/4" insulation from the white and striped wires and secure the white wire to the "W" terminal and the striped wire to the "B/W" terminal as shown. 4. Mark the wall console mounting holes, drill 3/32" pilot holes and mount with #6 x 1-1/4" screws. If mounting to drywall, anchors will be required (not provided). B/W W Wall Console Wires:
Striped Wire to B/W Terminal White Wire to W Terminal Main Activation Sure-Loc Activation Locks out all opener funtions
(vacation lock) Light Override Install and Wire -OPTIONAL N/C Interlock 1. Do not remove factory installed interlock wire. This jumper is required for proper opener operation. 2. Use of any commercially available normally closed dry interlocks can be used with this opener. Using a small flat head screwdriver, press in the orange tabs at INTR-LOCK terminals and remove factory installed jumper wire and insert the interlock wires. Install Bottom Cover Onto Opener - OMIT THIS STEP IF INSTALLING BATTERY BACK-UP 1. Remove two screws on the sides of opener. 2. Route wires to the rear of opener to align with slot in rear of cover. 3. Install cover with screws removed in step 1. 14 WIRE THE OPENER (CONT) Apply power to opener
!
CAUTION DO NOT run opener until travel limits have been set to avoid damage to unit. NE PAS faire fonctionner louvre-porte au-del des limites de parcours pour ne pas endommager lunit.
!
CAUTION
!
WARNING Opener is equipped with grounded electrical plug for your protection, and only fits grounded electrical outlets. DO NOT alter plug in any way! If you have no grounded outlets, have one installed by a licensed electrician. Opener must be properly grounded to prevent personal injury and equipment damage. NEVER USE AN EXTENSION CORD! Check local building codes for any requirement that you must have a permanent hard-wired connection.
!
AVERTISSEMENT Loprateur, qui est quip dune prise lectrique mise la terre pour votre protection est compatible uniquement avec des prises lectriques mises la terre. NE PAS modifier la fiche dune quelconque manire. Si vous navez pas de prises mises la terre, faites-en installer par un lectricien agr. Loprateur doit tre correctement mis la terre pour viter les blessures corporelles et des dommages matriels. NE JAMAIS UTILISER DE RALLONGE! Vrifiez les codes locaux des btiments pour connexions cbles permanente. Les connexions cbles permanentes doivent tre effectues par un lectricien agr qui se servira doutils appropris et respectera les consignes. FOR GROUNDED OUTLET CONNECTION:
Plug in the power cord to standard 115 VAC outlet. Coil excess cord and tape or twist tie it to top of powerhead. DO NOT USE EXTENSION CORDS TO POWER THIS OPENER. Extender power input kits are available. 15 5 OPENER PROGRAMMING & ACCESSORY INSTALLATIONS NOTE: Before programming the opener, check to make sure there are no objects in the garage door opening. DO NOT allow persons to enter the area of the door while programming and operating. The following steps list the order of programming the openers functional settings and install any accessories that were included with the opener or purchased separately. These steps should be performed in order. 1. Down Travel Limit 2. Up Travel Limit 3. Force Control 4. Contact Reverse test and adjustment 5. Remote Control Programming 6. Wireless Wall Console Programming Remote control(s), Bluetooth Lighting System and Wireless Wall Console included with this opener are programmed at the factory. The information provided on these pages should be used if adding additional remote controls or wireless wall consoles are used. 7. Accessory Installation and/or Programming Program wireless keypad (If applicable) Program built in vehicle remote (If applicable) Program the Integrated Aladdin Connect (If applicable) Install Battery Backup (BBU) (If applicable) NOTE: When opener is activated to close, opener will start and stop slowly in small increments to detect cable tension then run at normal speed to close. This is normal operation. Programming Button Layout Wi-Fi Program Wi-Fi LED Program/Set Long LED Indicator Round LED Indicator Close Travel Button Open Travel Button NOTE: Each programming step has a 30 second time limit for completion after the function is initiated. After 30 seconds, both LEDs will illuminate RED indicating time has expired and the step must be restarted. Restart the step as many times as necessary to complete the programming. 16 PROGRAMMING THE DOWN LIMIT
!
WARNING
!
AVERTISSEMENT Make sure doorway is in full view and clear of obstacles and people to avoid injury or property damage. DO NOT operate this unit from the wall control before LIMITS are set. Severe damage to the opener could occur. The carriage MUST be engaged to turnbuckle BEFORE setting limits. See installation poster or call Customer Service at 1-800-35-GENIE or visit www.geniecompany.com. DO NOT set limits with Battery Backup attached. AC power MUST be connected to the opener while setting limits for proper operation. Sassurer que le passage de la porte est visible et dgag, savoir sans obstacles ni personne afin dviter toute blessure potentielle ou dommage matriel. NE PAS utiliser cette unit avec la console murale avant davoir rgl les LIMITES. Louvre-porte pourrait subir de srieux dommages. La tendeur DOIT tre engage dans le chariot AVANT de rgler les limites. Voir le poster dinstallation (si fourni) ou appelez le service clientle au 1-800-35-GENIE Door ou visitez le site www.geniecompany.com. NE PAS fixer de limites en mode batterie de secours. Lalimentation CA DOIT tre branche sur louvre-porte, pendant le rglage des limites, pour assurer un bon fonctionnement.
!
NOTE: Door MUST be locked to the opener prior to programming. Door should rest somewhere between full open and closed. Do not start with door fully open or closed. TO ENGAGE DOOR TO OPENER:
Pull release cable and release to retract cable and engage opener. 1-2. Enter Programming Mode Steady Blue HOLD UNTIL LED Lights Programming DOWN Limit:
1. Press and hold the DOWN arrow button. Long LED will light BLUE. 2. Release DOWN arrow button. Long LED will flash BLUE. 3. Press and hold the DOWN arrow button until door is fully closed. Use the UP arrow button if door closes too far. Use both UP and DOWN buttons to adjust close travel as necessary. Door should rest on the floor until the weather strip is compressed enough to seal along the width of the door. Damaged doors or uneven floors may not seal properly. Repair these conditions to achieve a proper seal. DO NOT compress seal so much that the door will bend or buckle. 4. Press and release the SET/PRGM button Both LEDs will flash BLUE then go out. The DOWN limit is now programmed. Flashing Blue RELEASE 3. Adjust Door Position 4. Lock Programming Flashing Blue PRESS
&
RELEASE 17 PROGRAMMING THE UP LIMIT Programming UP Limit:
1. Press and hold the UP arrow button. Long LED will light BLUE. 2. Release UP arrow button. Round LED will flash BLUE. 1-2. Enter Programming Mode Steady Blue 3. Press and hold the UP arrow button until door is fully open. Use the DOWN arrow button if door opens too far. Use both UP and DOWN buttons to adjust open travel as necessary. SECTIONAL DOOR UP LIMIT:
Door should fully open so that door seal is about even with door header. Do not adjust so much that the door will bend, buckle or stretch door spring cables backward. Flashing Blue 4. Press and release the SET/PRGM button Both LEDs will flash BLUE then go out. The UP limit is now programmed. 3. Adjust Door Position 4. Lock Programming Flashing Blue 18 HOLD UNTIL LED Lights RELEASE PRESS
&
RELEASE
1 | Exhibit C External Photographs per 2 1033 b7 | External Photos | 767.76 KiB |
FRONT VIEW BACK VIEW RIGHT SIDE VIEW LEFT SIDE VIEW
1 | Exhibit C Internal Photographs per 2 1033 b7 | Internal Photos | 1.98 MiB |
INTERNAL VIEW WITHOUT FRONT PANEL INTERNAL VIEW FRONT PANEL MAIN BOARD TOP VIEW MAIN BOARD BOTTOM VIEW iDCM BOARD TOP VIEW iDCM BOARD BOTTOM VIEW
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2019-09-27 | 2402 ~ 2480 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2019-09-27
|
||||
1 | Applicant's complete, legal business name |
The Genie Company a Division of Overhead Door Corporation
|
||||
1 | FCC Registration Number (FRN) |
0004055760
|
||||
1 | Physical Address |
1 Door Drive
|
||||
1 |
67
|
|||||
1 |
Mt. Hope, TX
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
d******@elitetest.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
B8Q
|
||||
1 | Equipment Product Code |
BLEWM
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
M**** W****
|
||||
1 | Title |
RF Engineer
|
||||
1 | Telephone Number |
830-6********
|
||||
1 | Fax Number |
330-7********
|
||||
1 |
m******@geniecompany.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Residential & Light Duty Commercial Jackshaft Operator - Wall Mount | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Output power is conducted. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter not described in this application. End-users and installers must be provided with specific operating instructions for satisfying RF exposure compliance. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Elite Electronic Engineering Inc.
|
||||
1 | Name |
K**** H********
|
||||
1 | Telephone Number |
630-4******** Extension:
|
||||
1 | Fax Number |
630-4********
|
||||
1 |
k******@elitetest.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2402.00000000 | 2480.00000000 | 0.0002750 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC