EXCEPTIONS FROM RESPONSIBILITY 1)The user of this product is expected to follow all operating instructions and make periodic checks of the products performance. 2)The manufacturer, or its representatives, assumes no responsibility for results of a faulty or intentional usage or misuse including any direct, indirect, consequential damage, and loss of profits. 3)The manufacturer, or its representatives, assumes no responsibility for consequential damage, and loss of profits by any disaster, (an earthquake, storms, floods etc.). A fire, accident, or an act of a third party and/or a usage any other usual conditions. 4)The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits due to a change of data, loss of data, an interruption of business etc., caused by using the product or an unusable product. 5)The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits caused by usage except for explained in the user manual. 6)The manufacturer, or its representatives, assumes no responsibility for damage caused by wrong movement, or action due to connecting with other products. Standard Set Composition 1 RD-100W Instrument ..................................... 1pc. 2 AA-size dry cells............................................. 3pcs. 3 Instruction manual.......................................... 1pc. INSTRUCTION MANUAL REMOTE DISPLAY RD-100W Thank you for purchasing the TOPCON RD-100W. For the best performance of the instruments, please read these instruc-
tions carefully and keep them in a convenient location for future refer-
ence. GENERAL HANDLING PRECAUTIONS Before starting work or operation, be sure to check that the system is functioning properly. Affection of the radio waves When using the instrument in the following place, the strong radio wave may cause faulty operation. Near the instrument occurring strong radio waves. (e.g. Transceiver) Near the radio wave towers such as television or radio. DISPLAY FOR SAFE USE In order to encourage the safe use of products and prevent any danger to the operator and others or damage to properties, important warnings are put on the products and inserted in the instruction manuals. We suggest that everyone understand the meaning of the following dis-
plays and icons before reading the Safety Cautions and text. Display WARNING Ignoring or disregard of this display may lead to death or serious injury. Meaning CAUTION Ignoring or disregard of this display may lead to per-
sonal injury or physical damage to the instrument. Injury refers to hurt, burn, electric shock, etc. Physical damage refers to extensive damage to buildings or equipment and furniture. HANDLING PRECAUTIONS Guarding the instrument against shock When transporting the instrument, provide some protection to minimize risk of shock. Heavy shock may affect beam accuracy. SAFETY CAUTIONS WARNING There is a risk of fire, electric shock or physical harm if you attempt to disassemble or repair the instrument yourself. This is only to be carried out by TOPCON or an authorized dealer, only!
Risk of fire or electric shock. Do not use damaged power cable, plug and socket. Risk of fire or electric shock. Do not use a wet battery. May ignite explosively. Never use an instrument near flammable gas, liquid matter, and do not use in a coal mine. Do not hold the RD-100W magnetic clamp near anyone who uses a pace maker or other electronic medical devices. The strong magnetic field can disrupt the normal operation of such devices. Battery can cause explosion or injury. Do not dispose in fire or heat. The short circuit of a battery can cause a fire. Do not short circuit battery when storing it. CAUTION Risk of injury to fingers. Do not place fingers on magnet while mounting to equipment. Strong magnetic field. Do not place RD-100W magnetic clamp near any sensitive electronic devices or magnetic storage media such as computer disk. Do not allow skin or clothing to come into contact with acid from the batteries, if this does occur then wash off with copious amounts of water and seek med-
ical advice. Nomenclature and Functions Wireless communication switch Communication ON/OFF: Short push Communication default setting: Long push Indicator(LED) Buzzer speaker Wireless communication LED Zero-set switch Magnet Buzzer sound switch Buzzer sound: Quiet/Loud/OFF:Short push LED ON/OFF: Long push Power switch Power ON: Short push Power OFF: Long push LCD back light ON/OFF:
Short push when power is ON
(Auto turn-off after two minutes) Detective precision (Mode) switch Tilt switch Indicator(LCD) Battery cover Battery cover knob Risk of damage to installation surface of machine, because it uses a strong magnet. See [Laser beam positions and display patterns] in the Instruction manual for the display area and display pattern. This instrument is able to perform wireless communication with the LS-B110W/LS-B10W, sold separately. See the LS-B110W/LS-B10W Instruction manual for details on the LS-B110W/LS-B10W. How to set up the wireless communication default setting Place the LS-B110W/LS-B10W and RD-100W in close position, so that they will not be affected by other wireless communications. 1 Turn on the power for both the LS-B110W/LS-B10W and RD-100W. 2 Long-push the wireless communication switch for the LS-B110W/LS-B10W and RD-100W. While setting up, the wireless communi-
cation LED (yellow light) will turn on. 3 When the instrument is ready to be used, a buzzer will sound (buzzer sound: peep) and the communication will begin. If the communication fails, a buzzer will sound (buzzer sound: pi, pi, pi). Eliminate any influence from other wireless instrument and redo the communication default setting. While setting up the default, only the default OFF (short-push of the wireless communication switch) is operable. How to use wireless communication 1 When power for both the LS-B110W/LS-B10W and RD-100W are turned ON, communication will automatically begin. During communication, the wireless communication LED will flash quickly. During communication preparation, the wireless communication LED will flash slowly When beginning the communication with LS-B110W, detective precision, tilt direction, tilt precision and ON-GRADE position setting will be changed to the same setting as the LS-B110W. When the detective precision, tilt direction, tilt precision or ON-GRADE position settings are changed while communicating with LS-
B110W, the setting for the LS-B110W will also change in conjunction with the RD-100W. When begining the communication with LS-B10W, detective precision, buzzer sound, LED ON/OFF setting will be changed to the same setting as the LS-B10W. When the detective precision, buzzer sound or LED ON/OFF settings are changed while communicating with LS-B10W, the setting for the LS-B10W will also change in conjunction with the RD-100W. If you wish to change the LS-B110W/LS-B10W to communicate, redo the communication default setting. Lighting/Flashing pattern of wireless communication LED Lights While setting up the default Flashes quickly Flashes slowly While LS-B110W/LS-B10W is communicating Communication is in preparation Indicator Height alert warning of rotating laser A flash and a buzzer sound signifies that the height alert function of rotating laser is operating.
(This function is not usable to the rotat-
ing laser which does not have the height alert and the function to output alarm signal.) Indicator(LED) Flashes slowly Precision mode Mode1 Mode2 Mode3 Mode4 (Blinking) Higher than datum position Move the sensor downward.
(Buzzer sound:High frequent beep sound) Datum position (ON GRADE position)
(Buzzer sound:Continuous beep sound) Lower than datum position Move the sensor upward.
(Buzzer sound:Low frequent beep sound) Battery remaining display Indicates the battery remaining of remote display as follows. Battery is sufficient. Flashing alternately The power is low, but remote display is still usable. Rotating laser battery warning A flash shows that the rotating laser power is low.
(This function is not usable to the rotating laser which does not have the function to output alarm signal.) Dead battery. Replace the dry battery with new one. Auto-cut off function The power will be turned off automatically after not communicating with LS-B110W/LS-B10W for more than approx. 5 minutes.
(To turn on the power, press the power switch again.) Laser beam positions and display patterns During communication with LS-B10W Indicator(LCD) Indicator(LED) Laser beam positions and display patterns During communication with LS-B110W Indicator(LCD) Indicator(LED) Detective precision Mode1:3mm Mode2:6mm Mode3:15mm Mode4:30mm 15mm/0.05ft
(30mm/0.1ft width) No display when in Mode 3 and 4 No display when in Mode 4 30mm/0.1ft
(60mm/0.2ft width) No display when in Mode 4 No display when in Mode 4 Flashes quickly Flashes quickly 50mm/0.16ft
(100mm/0.33ft width) 70mm/0.23ft
(140mm/0.46ft width) Flashes slowly 125mm/0.41ft
(250mm/0.82ft width) Detective precision Mode1:2mm Mode2:6mm Mode3:12mm Mode4:30mm 15mm/0.05ft
(30mm/0.1ft width) 25mm/0.08ft
(50mm/0.16ft width) 35mm/0.11ft
(70mm/0.23ft width) 60mm/0.2ft
(120mm/0.39ft width) Flashes slowly When the laser beam is off to the top or to the bottom When the laser beam is off to the top or to the bottom Flashes more slowly Flashes more slowly Tilt detection function (During communication with LS-B110W only) Switching the tilt direction The tilt direction can be changed. 1 Long-push the detective precision switch and the tilt switch at the same time. The tilt direction mode setting changes in the following order: "Back and Forth," "OFF" and "Right and Left."
At this time, the LED above the mark indicating the tilt direction will flash. The LED will not flash when the tilt detection function is switched OFF. The LED lights up as shown in the figure for three seconds when you have failed to change the ON-GRADE position. Be careful not to change the position at which the laser beam is detected and try setting once again. The LED display and LCD display while changing the ON-
GRADE position The LED display indicating beam position and the LED (1 green) in the center will flash. The mark showing laser beam position on the LCD will flash. Tilt direction mark :
Back and Forth Tilt direction mark :
Right and Left Flashes Switching the tilt precision 1 Short-push the tilt switch. The tilt precision will change. At this time, the LED below the mark indicating the tilt precision will light up. Tilt precision mark :
High precision Tilt precision mark :
Normal precision Zero position setting for the tilt sensor Before using the tilt detection function, set the zero position of the tilt sensor according to the directions below. The tilt direction must be set before setting the zero position. 1 Raise or lower the machine blade or arm where the LS-B110W is installed to position the cutting edge or bucket at the desired slope. 2 Long-push the tilt switch on RD-100W. The tilt angle for the LS-B110W will set to 0. The LED (1 green) lights up as shown in the figure for three seconds when the zero position is set. The LED (2 red) flashes as shown in the figure for three seconds when you have failed to set the zero position. Tilt angles and display patterns Tilt directions : Right and Left Flashes quickly Flashes slowly Tilt directions : Back and Forth High precision Normal precision
: 1
: 2.5 5 More than 5 High precision Normal precision
: 1
: 2.5 High precision Normal precision
: More than 1
: More than 2.5 Lights off Tilt indication will be displayed during laser detection and for 20 seconds after switch operation. Changing the ON-GRADE position function
(During communication with LS-B110W only) The ON-GRADE position can be changed to the position where laser beam is detected. Using this function when installing the LS-B110W on the pole of the machine allows easy setting of the height at which the ON-GRADE will be displayed on the LS-B110W. The range in which the ON-GRADE position can be changed is 75mm (total of 150mm) from the center of the detective range. 1 Long-push the zero-set switch while detecting the laser beam. When changing the ON-GRADE position, the LED lights up for three seconds, as shown in the figure. The position where the laser beam is being detected will be the ON-GRADE position. Cancellation the ON-GRADE position change 1 Long-push the zero-set switch when not detecting the laser beam. The ON-GRADE position will be reset. When the ON-GRADE position change is cancelled, the LED (3 green) will flash for three seconds. FCC WARNING Changes or modifications not expressly approved by the manufacturer for compliance could void the users authority to operate the equipment. In order to comply with FCC radio-frequency radiation exposure guidelines for an uncontrolled exposure, this device and its antenna must not be co-
located or operating in conjunction with any other antenna or transmitter. This equipment complies with FCC/IC radiation exposure limits set forth for uncontrolled equipment and meets the FCC radio frequency (RF) Expo-
sure Guidelines in Supplement C to OET65 and RSS-102 of the IC radio frequency (RF) Exposure rules. This equipment has very low levels of RF energy that it is deemed to comply without testing of specific absorption ratio (SAR). This device complies with Part 15 of FCC Rules and RSS-Gen of IC Rules. Operation is subject to the following two conditions : (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of this device. Specifications Wireless communication range Power source Continuous operating time
(+20C/+68F) Operating temperature Water proof Dimensions (W/D/H) Weight (Without cells)
20m
(May vary depending on obstacles between the two instruments and other conditions) AA-size dry cells 3pcs. Approximately 40 hours
(Using alkaline manganese dry cells)
-20C~+50C(-4F~+122F) IP66 (Based on the standard IEC60529) 110x36x176(mm) (4.3x1.4x6.9) 0.5kg (1.2lbs) Detective angle, Detective precision and Laser detecting range may vary depending on rotating laser being used or atmospheric conditions. 7400 National Drive, Livermore, CA 94551, U.S.A. Phone: 925-245-8300 Fax: 925-245-8599 www.Topconpositioning.com 3380 Industrial Blvd, Suite 105, West Sacramento, CA 95691, U.S.A. Phone: 916-374-8575 Fax: 916-374-8329 Essebaan 11, 2908 LJ Capelle a/d IJssel, The Netherlands. Phone: 010-458-5077 Fax: 010-284-4941 www.topconeurope.com Unit 69 Western Parkway Business Center Lower Ballymount Road, Dublin 12, Lreland Phone: 01460-0021 Fax: 01460-0129 Giesserallee 31, 47877 Willich, GERMANY Phone: 02154-885-100 Fax: 02154-885-111 info@topcon.de www.topcon.de 89, Rue de Paris, 92585 Clichy, Cedex, France. Phone: 33-1-41069490 Fax: 33-1-47390251 topcon@topcon.fr Phone: 031-7109200 Fax: 031-7109249 Topcon House Kennet Side, Bone Lane, Newbury, Berkshire RG14 5PX U.K. Phone: 44-1635-551120 Fax: 44-1635-551170 survey.sales@topcon.co.uk laser.sales@topcon.co.uk Blk 192 Pandan Loop, #07-01 Pantech Industrial Complex, Singapore 128381 Phone: 65-6778-3456 Fax: 65-6773-6550 www.topcon.com.sg 77/162 Sinn Sathorn Tower, 37th Fl., Krungdhonburi Rd., Klongtonsai, Klongsarn, Bangkok 10600 Thailand. Phone: 66-2-4401152~7 Fax: 66-2-4401158 No.D1, (Ground, Lower Ground & 1st Floor), Jalan Excella 2, Off Jalan Ampang Putra, Taman Ampang Hilir, 55100 Kuala Lumpur, Malaysia Phone: 60-3-42709866 Fax: 60-3-42709766 2F Yooseoung Bldg., 1595-3, Seocho-Dong, Seocho-gu, Seoul, 137-876, Korea. Phone: 82-2-2055-0321 Fax: 82-2-2055-0319 www.topcon.co.kr Block No.9, Kangding Street Beijing Economic-Technological Development Area, Beijing, 100176, China Phone: 86-10-6780-2799 Fax: 86-10-6780-2790 P. O Box293705, Office C-25(row C-2), Dubai Airport Free Zone, Dubai, UAE Phone: 971-4-2995900 Fax: 971-4-2995901 marketing@Topcon.ae 75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan www.topcon.co.jp 31267 90111 6F