Wire Your Switch 1 Turn off the circuit breaker. Then remove the old wallplate of the wall switch and label the wires. 3 Connect the wires to the smart switch as shown below. 4 Line up the switch with the mounting holes. Secure it with screws. 5 Attach the wallplate and turn on the circuit breaker. Then the wiring is finished. Ground: Usually green or copper. Neutral: Usually white, not connected to the dumb switch. Line/Load: Usually black, and connected to the dumb switch. If you are unsure, consult a qualified electrician. 2 Disconnect wires from the old switch. Note: No need to distinguish between Line and Load wires. Set Up Your Switch STEP 1 DOWNLOAD APP Get the Kasa Smart app from the App Store or Google Play. OR STEP 2 SET UP Tap the button in the app. If your device is white, select Smart Switches > Smart Switch (Wi-Fi). If your device is black or almond, select Smart Switches > Smart Switch (BLE). And then follow app instructions to complete setup. Appearance Button Explanations Third-Party Services Reset On/Off Button LED Restart Reset Press and hold for about 5s until the LED blinks amber and green to reset Wi-Fi while keeping other settings. Press and hold for about 10s until the LED blinks amber to restore to factory default settings. Restart Press to restart your switch. LED Status Solid amber Starting up. Blinking amber & green Ready for setup;
Resetting Wi-Fi. Blinking green Connecting to Wi-Fi. Stay green for 30s Connected to Wi-Fi. Solid red Disconnected from Wi-Fi. Blinking amber Device resetting. White Light fixture is off. Kasa works with Alexa, Google Assistant, and other third-party services to control your switch by voice. Go to Me > Third-Party Services in the Kasa Smart app to integrate Third-Party Services. For step-by-step setup instructions, please visit:
Google Home Assistant:
https://www.tp-link.com/support/faq/1534/
Amazon Alexa:
https://www.tp-link.com/support/faq/944/
Specifications Rating: 100-120V~ 50/60Hz Load: 15 A General Use, 600 W Incandescent, 1/6 HP Motor Operation temperature: 0~40 Method of mounting included: Independently mounted (Vertically position only);
Operating control, Type 1.C action Pollution Degree 2, Rated Impulse Voltage 2500V Software Class A, NEMA Type 1 CAUTION High Voltage-Disconnect power supply before servicing MISE EN GARDE Haute tension. Dbrancher l'alimentation lectrique avant d'utiliser Safety Notice Before installing, servicing or removing the switch, read and follow all safety precautions including the following:
CAUTION Risk of Electric Shock More than one disconnect switch may be required to de-energize the equipment before servicing. A circuit breaker which disconnects the Line and Neutral conductor simultaneously is suitable. Ensure power is off at the circuit breaker before removing or installing any switch. Use a non-contact voltage tester to ensure the power is off. The Smart Switch must be installed and used in accordance with the National Electric Code (NEC) or your local electrical code. If you are unfamiliar with these codes and requirements, or are uncomfortable performing the installation, consult a qualified electrician. Do not install the Smart Switch with wet hands or when standing on wet or damp surfaces. Install only in a suitable UL Listed outlet box (suitable dimensions:
H > 2.95 in./75 mm, W > 1.81 in./46 mm, D > 2 in./51 mm). Support Quick Start Guide Kasa Smart Wi-Fi Light Switch, Single Pole HS200/HS200-LA/HS200-BL For technical support, the user guide and other information, visit https://www.tp-link.com/support/. 2023 TP-Link 7106510623 REV6.0.0
*Images may differ from your actual product. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement This device complies with FCC radiation exposure limits set forth for an uncontrolled environment and it also complies with Part 15 of the FCC RF Rules. This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and consider removing the no-collocation statement. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
Th
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Caution!
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. We, TP-Link USA Corporation, has determined that the equipment shown as above has been shown to comply with the applicable technical standards, FCC part 15. There is no unauthorized change is made in the equipment and the equipment is properly maintained and operated. Canadian Compliance Statement This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canadas licence-exempt RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired operation of the device. Lmetteur/rcepteur exempt de licence contenu dans le prsent appareil est conforme aux CNR dInnovation, Sciences et Dveloppement conomique Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
1) Lappareil ne doit pas produire de brouillage;
2) Lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. Radiation Exposure Statement:
This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Dclaration d'exposition aux radiations:
Cet quipement est conforme aux limites d'exposition aux rayonnements IC tablies pour un environnement non contrl. Cet quipement doit tre install et utilis avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. Industry Canada Statement CAN ICES-3 (B)/NMB-3(B