SHUTTIE Installation Manual Warning! This product includes moving parts. Keep your fingers or any other objects away. Warning! This product was designed to prevent water leakage damages and should be used for this purpose only. SHUTTIE SPECIFICATION Part No. Product description Dimensions Weight Power supply Operation voltage Battery life span Operating RF Transmission range Certification IP Rating IEC60529 Working temperature HDW-000081-001 The wireless, battery operated water Actuator is mounted on an ISO5211 ball valve installed on the main water line. The water supply automatically shuts off whenever a leak is detected. Shutoff can also be manually controlled by the user. 142x73x92mm (5.6x2.87x3.62) 640g (22.5 oz) 4 x 3V batteries (CR123A) 6V Up to four years based on one operation per day/5 days a week. 915 MHz Open space - up to 230 m (750 ft.) In enclosed space - up to 120 m (390 ft.) Avoid installing in a metal cabinet. FCC: 2AFOILOR IC: 20798-LOR IP67
-20C to +50C (-40F to +1220F) IC STATEMENTS This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canadas licence-exempt RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired operation of the device. Lmetteur/rcepteur exempt de licence contenu dans le prsent appareil est conforme aux CNR dInnovation, Sciences et Dveloppement conomique Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
1) Lappareil ne doit pas produire de brouillage;
2) Lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. AVERTISSEMENT CONFORMIT AUX NORMES DEXPOSITION AUX RF : Cet quipement doit tre install et utilis une distance mini-
male de 20 cm entre le radiateur et votre corps. FCC STATEMENTS This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to oper-
ate this equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protec-
tion against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. WARNING RF EXPOSURE COMPLIANCE: This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numerique de la classe B est conforme a la norme NMB-003 du Canada. Whats Included Shuttie Actuator Valve Perpendicular Actuator Mount Perpendicular Valve Adapter Insert Inline Actuator Mount Inline Valve Adapter Insert 7 8 9 10 11 12 T-Shaped Key Screws Lock washers Nuts Batteries Shuttie Installation Manual 1 2 3 4 5 6 1 3 5 4 6 2 7 Installation manual Guide d'installation Installation manual Guide d'installation 12 8 9 11 10 What You Need 1 Phillips Head Screwdriver Installation manual Guide d'installation What To Do First 1 2 Call a plumber Ask the plumber to install the ball valve because the water pipe will need to be cut. A plumber installed this valve Installation Options Shuttie can be installed either inline or perpendicular to the water line. Inline Installation:
Perpendicular Installation:
Installing Shuttie Before you begin installing Shuttie, watch the video at alertlabs.com/ShuttieInstall. Remove Shuttie from the box and remove the plastic wrap from the batteries. NOTE: When the batteries are first installed and the compartment is closed, Shuttie will automatically start a cleaning process where it will close and then open again. RED - Error BLUE - Communication fault GREEN - Operating OFF - No power 1 Inserting The Batteries Loosen the screw on the bottom of the battery compartment to remove the cap using a Phillips-head #1 screwdriver. Place all 4 x CR123 batteries into the compartment with + end facing the orange button side of the Shuttie. Place the cap back onto the compartment. Align the edges of the cap and compartment before tightening the screw to make sure it closes properly. Press the orange button briefly to check the Shuttie LED status color. It should be green. LONG ACTUATOR MOUNT In-line installation SHORT ACTUATOR MOUNT Perpendicular installation 2 Installing The Adapter Open a water tap briefly to confirm that the valve is open and water is running. If the valve is closed, turn it 90 degrees using a wrench. Select the actuator mount according to installation type. Remove the one you need from the box. LONG ACTUATOR MOUNT - In-line installation SHORT ACTUATOR MOUNT - Perpendicular installation Remove the gray star-shaped valve adapter insert from inside the actuator mount. IN-LINE INSTALLATION PERPENDICULAR INSTALLATION 3 Place the valve adapter insert onto the valve. The direction of the rectangular slot will depend on the type of installation (see images above). PARALLEL to the pipe - In-line installation PERPENDICULAR to the pipe - Perpendicular installation. 4 Slide the gray actuator mount over the valve adapter insert, aligning the screw holes on the water valve. NOTE: There are 2 holes for screws on opposite corners of the actuator mount that align to the holes on the water valve. 5 Next you will need the bag of screws, lock washers and nuts. Insert the screws through the mount and valve. Tighten the nuts with lock washers onto the screws. NOTE: You will know the screws are fully tightened when the hexagon screw heads fit inside the cut-outs in the adapter mount. Brass actuator shaft in open position 6 Mounting Shuttie Make sure Shuttie is set to the open position. When the line of the brass actuator shaft is horizontal, Shuttie is in the open position
. The metal locking pin must also be pulled out so that Shuttie can slide onto the adapter mount. 7 Slide Shuttie onto the actuator mount by inserting the brass actuator shaft into the rectangular slot. 8 Make sure that you have access to the metal locking pin once Shuttie is attached. Push the metal locking pin into its slots to lock the valve adapter in place. Brass actuator shaft in closed position 9 Now you can test that valve will close. Press and hold the orange button for 5 seconds then release. The line of the brass actuator shaft will move to a vertical position to match pipe stops. Test that the valve will open. Press and hold the orange button again for 5 seconds then release. The line of the actuator shaft will move to the horizontal position to match
. Turn on a water tap to confirm that water flow through the
. NOTE: When testing is complete, remember to turn the water tap off again. TroubleShooting How do I know if the water valve is open?
Open a water tap briefly to confirm that the valve is open and water is running. How do I open the water valve if its closed?
If the valve is closed at the beginning of the installation process, turn the valve 90 degrees with a wrench. After the adapter is installed you can use the T-shaped key that comes in the Shuttie box. Need help?