All the reassurance you need Fall Detector User Instructions Activity indicator Belt /
clothing clip Manual trigger button Battery Cover D66070xx Issue A Page 1 of 10 All the reassurance you need Your fall detector is a battery operated device containing a microprocessor, detector and a radio transmitter. It will automatically trigger an alarm call on your community alarm system if it detects that you have fallen. You can also use it to manually raise an alarm call. Wearing the fall detector Clip the fall detector to your belt or clothing in the upright position shown in the drawing. It needs to be in the upright position to reduce the possibility of false activation.
Upright position Incorrect position D66070xx Issue A Page 2 of 10 All the reassurance you need Automatic fall detection Green light and two "beeps" indicates that the fall detector has been activated. The fall detector will then monitor for between 6 and 15 seconds to verify if there could have been a fall. The green light will flash while it does this. If the detector has decided that there is a fall, then a red light and four "beeps"
indicates that the fall detector is about to trigger an alarm call (because it has detected an impact and has not been upright for between 6 and 15 seconds). If the detector has decided that it was activated by error then the green flashing light will stop after between 6 to 15 Seconds and the unit will revert to normal again. Due to the complex dynamics of falling, all falls may not be detected. In this unlikely event the manual button can still be used to call for help. D66070xx Issue A Page 3 of 10 All the reassurance you need Manual operation Press the button on the fall detector to raise a manual alarm call. The fall detector will "beep" and a red light indicates the fall detector is triggering an alarm call. If the red light flashes on and off, the fall detector is still triggering an alarm call, but is also indicating to you that the battery needs to be replaced. D66070xx Issue A Page 4 of 10 All the reassurance you need Remember, the fall detector will only detect you falling if you are wearing it. The fall detector must be worn at or above the waist, where it will detect the maximum number of falls. When removing the fall detector, handle carefully to avoid false calls, place it on an even surface in the upright position and preferably in the stand provided. If the fall detector does wake up and beep when you know you have not fallen, you can prevent it raising an alarm by ensuring that it is returned to an upright position. It is not recommended that you wear the fall detector whilst in bed, as normal movement in bed will cause the fall detector to trigger. D66070xx Issue A Page 5 of 10 All the reassurance you need Battery Replacement From time to time the battery will need replacing, you will know this because somebody from your monitoring service (if you have one) may inform you, or you may see the red light flashing rather than staying on continuously when a manual alarm call is made. The unit automatically tests the battery several times within each 24 hour period. It is able to automatically generate an alarm call when low battery is detected. If it is necessary for you to change the battery, the fall detector uses a 6 volt Duracell PX28L battery. To access the battery, remove the battery cover screw and then the battery cover by sliding it in the direction of the arrow. After a year the battery should be replaced. Contact your provider for a replacement. In many cases your provider will change the battery for you. On the back of this user guide is a handy table to D66070xx Issue A Page 6 of 10 All the reassurance you need help you remember when the battery should be changed. Remove battery and replace it with the new battery, remember to observe the correct orientation. When the battery is first placed in the unit an automatic test call will be generated (no lights will show and no buzzer will sound). Replace the sliding cover and the screw. Test the fall detector by making a manual call. Inform the operator that you are making a battery test call. If the device fails to make a test call then check the orientation of the battery. If this is correct then contact your supplier. 1. First remove the screw. 2. Then slide the cover off in the direction of the arrow.
+ 3. Orientation
(copper end). Do not dispose of the old battery in the bin, please return it to Tunstall (c/o Service Centre) at the address shown overleaf. Page 7 of 10 D66070xx Issue A Li All the reassurance you need Care of the fall detector Avoid getting the fall detector wet (if it does then dry it quickly and make a manual test call to confirm it is working correctly). If required, the fall detector may be cleaned periodically with a damp cloth and mild detergent. It is recommended that you test the fall detector once a month:
Make a manual test call. Tap the fall detector when it is lying down. After 5 Seconds the fall detector should beep and the green light start to flash. If you put the unit quickly back upright (in its stand, for instance), the alarm call will not be raised. Manufactured By Tunstall Telecom Ltd. Whitley Lodge Whitley Bridge Yorkshire DN14 OHR Tel : 01977 661234 Fax: 01977 662963 www.tunstallgroup.com D66070xx Issue A Supplied By Page 8 of 10 All the reassurance you need Radio Approval Notices Australia The Fall Detector operates on a frequency of 312MHz and is certified approved by TRL Compliance to AS/NZS 4268:2003 Canada Canadian Certification Approvals Number IC: 1231A-66004A USA Federal Communications Commission (FCC) notices to provide residential This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed reasonable protection against harmful interference in a installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no interference will not guarantee occur in a particular installation. If this harmful equipment interference television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
cause radio or does to that Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. D66070xx Issue A Fall Detector Radio Trigger Model Numbers 66004/01 66004/02 66004/03 66004/04 FCC ID: G2X-66004A This Device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any including interference interference cause undesired operation. received, that may Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Page 9 of 10 All the reassurance you need Battery Replacement Guide Battery Inserted Date Year Day Month Battery Replacement Date Year Month Day Remember to change the battery once a year. N72 D66070xx Issue A Page 10 of 10