all | frequencies |
|
|
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|---|---|
manuals | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 2 |
|
Users Manual Ratiometric Transmitter | Users Manual | 2.32 MiB | December 16 2022 / March 01 2023 | delayed release | ||
1 2 |
|
Users Manual Temperature Transmitter | Users Manual | 2.56 MiB | December 16 2022 / March 01 2023 | delayed release | ||
1 2 |
|
Users Manual Vibration Sensor | Users Manual | 3.91 MiB | December 16 2022 / March 01 2023 | delayed release | ||
1 2 |
|
Internal photos | Internal Photos | 514.95 KiB | December 16 2022 / March 01 2023 | delayed release | ||
1 2 |
|
External Photos | External Photos | 545.58 KiB | December 16 2022 / March 01 2023 | delayed release | ||
1 2 |
|
ID Label/Location Info | ID Label/Location Info | 164.24 KiB | December 16 2022 / December 20 2022 | |||
1 2 |
|
Declaration of Conformity Concept | Cover Letter(s) | 49.99 KiB | December 16 2022 / December 20 2022 | |||
1 2 |
|
Declaration of authorization | Cover Letter(s) | 41.77 KiB | December 16 2022 / December 20 2022 | |||
1 2 |
|
Test Report P000052180 001 Ver 3.10 | Test Report | 1.76 MiB | December 16 2022 / December 20 2022 | |||
1 2 |
|
Test Report P000052180 002 Ver 3.00 | Test Report | 636.73 KiB | December 16 2022 / December 20 2022 | |||
1 2 |
|
Test Report P000052180 003 Ver 2.00 | Test Report | 776.01 KiB | December 16 2022 / December 20 2022 | |||
1 2 |
|
Test Setup Photos | Test Setup Photos | 866.46 KiB | December 16 2022 / March 01 2023 | delayed release | ||
1 2 |
|
confidentiality | Cover Letter(s) | 168.39 KiB | December 16 2022 / December 20 2022 | |||
1 2 | RF Exposure Info | December 16 2022 / December 20 2022 |
1 2 | Users Manual Ratiometric Transmitter | Users Manual | 2.32 MiB | December 16 2022 / March 01 2023 | delayed release |
Ratiometric Transmitter Product Manual This document applies to version 1 of the:
NEON Ratiometric Transmitter (DS-RT-02-XX) NEON Pressure Sensor (DS-PS-02-XX) NEON Pressure Gauge (DS-PG-02-XX) NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 Version A2 24-11-2022 Co XX F Lo XX mHPo = XX mW Contents 1 TWTG NEON 1.1 NEON Product Introduction . 1.2 Related Products . 1.3 What you will need . 2 Getting Started
. 2.1 Compatibility of this manual 2.2 Related Documents . 2.3 What is in the box . 2.4 Product Specifications RT . 2.5 Certifications . 2.6 Product Type Identification . 2.6.1 NFC . 2.6.2 Data Matrix Code . 2.7 Product Dimensions . 4 4 4 4 5 5 5 5 6 7 8 8 8 9 3 Warnings 10 3.1 ATEX / IECEx . 10 3.1.1 Specific Conditions of Use . 10 3.1.2 Installation . 10 3.1.3 Operation . 10 3.1.4 Service . 10 3.1.5 Output parameters . 11 3.2 General . 11 3.2.1 Transport and Storage . 11 3.2.2 Warranty . 11
. 11 3.2.3 Warranty will be void in case of 4 Avertissements 12 4.1 ATEX / IECEx . 12 4.1.1 Conditions spcifiques dutilisation . 12 4.1.2 Installation . 12
. 12 4.1.3 Fonctionnement 4.1.4 Entretien . 12 4.1.5 Output parameters . 13 4.2 Informations gnrales . 13 4.2.1 Transport et stockage . 13 4.2.2 Garantie . 13
. 13 4.2.3 La garantie sera annule dans les cas suivants:
5 Provisioning 14 5.1 User Interface . 14 5.2 Operating the Device . 14 5.2.1 Read device status . 14 5.2.2 Device Activation . 15 5.2.3 Device Deactivation . 16 NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 2 of 28 CONTENTS 6 Installation 17
. 17 6.1 Precautions 6.2 Mounting Bracket Dimensions . 17 6.3 Installation Methods . 18 6.3.1 Installation using mounting holes . 18 6.3.2 Installation using threaded holes . 18 6.3.3 Installation using bandclamp . 18 7 Product Functionalities 19 7.1 Application Event Message . 19 7.1.1 Event-triggers
. 19 7.1.2 Content application event message . 20 7.2 Device Status
. 20 7.3 Default Configuration . 20 8 Maintenance 21 8.1 Battery Specifications . 21 8.1.1 Battery Replacement . 21 8.1.2 Required tools . 21 8.1.3 Disassembly of device . 22 8.1.4 Built-In Self-Test Procedure . 23 8.1.5 Assembly of device . 24 9 Accessories and Spare Parts 10 EU Declaration of Conformity 11 FCC and ISED Declarations 25 26 27 3 of 28 NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 1 TWTG NEON 1 TWTG NEON 1.1 NEON Product Introduction NEON stands for a standardised approach to collecting data points from the operational environment and in doing so, creates a general approach to integrated data collection within existing IT ecosystems. The TWTG NEON product range supports all industrial customers moving towards LoRaWAN as the Industrial IoT network of the future. The LoRaWAN network gives industrial operations a secure solution, which scales-up to tens of thousands of sensors, covers complete sites with only a small amount of gateways and best of all the low-power approach means that the lifetime of the NEON products is extended dramatically. 1.2 Related Products Document name Document number NEON Vibration Sensor 6016_N02-09_Data-Sheet-NEON-Vibration-Sensor_XX NEON Temperature Transmitter 6015_N02-0_Data-Sheet-NEON-Temperature-Transmitter_XX NEON NFC Tag 6003_P20-018_Datasheet-NEON-NFC-Tag_XX NEON Temperature Sensor 604_P18-023_NEON-Data-Sheet-TS_XX NEON Contact Sensor NEON Valve Sensor MT NEON Valve Sensor QT 601_P20-017_NEON-Data-Sheet-CS_XX 604_P19-005_NEON-Data-Sheet-VS-MT_XX 607_P18-023_NEON-Data-Sheet-VS-QT_XX Table 1: Related Products 1.3 What you will need In order to deploy the NEON product range, a compatible and operational LoRaWAN network architecture is required. This manual does not contain any instructions of how to setup and install LoRaWAN networks. TWTG offers radio network planning and IT-architecture design services to fully integrate the products in the NEON product line. NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 4 of 28 2 GETTING STARTED 2 Getting Started 2.1 Compatibility of this manual This manual is applicable to version 1 of the NEON Ratiometric Transmitter, NEON Pressure Sensor and NEON Pressure Gauge. This manual is meant to be used with products from a specific production batch;
See Serial Number for an explanation on how to retrieve the production batch code from the serial number;
See chapter Data Matrix Code to determine the revision of the product. 2.2 Related Documents Document name Document number NEON Data Sheet Pressure Sensor 6033_N02-09_Data-Sheet-NEON-Pressure-Sensor Pressure Sensor installation manual 520_Drucksensor_BA NEON Data Sheet Pressure Gauge 6036_N02-09_Data-Sheet-NEON-Pressure-Gauge Pressure Gauge installation manual PDS_PG_IOM_Badotherm NEON Communication Protocol 6020_N02-09_Communication-Protocol-NEON-Ratiometric-Transmitter Table 2: Related documents 2.3 What is in the box When the product is delivered check the components for damage and whether all box items mentioned below are included. Box Items Pressure Sensor (DS-PS-02-XX) NEON Ratiometric Transmitter 1 battery assembly (included in the product) Sensor RT Sensor cable Declaration of Conformity 1 mounting bracket (mounted on the product) M12 connector (mounted on the product) Pressure Sensor DS-EC-02-AB03 (3 meter) Declaration of Conformity, containing a link to latest version of this product manual and other relevant product documentation Table 3: Box Items Pressure Sensor Box Items Pressure Gauge (DS-PG-02-XX) NEON Ratiometric Transmitter 1 battery assembly (included in the product) Sensor RT Sensor cable Declaration of Conformity 1 mounting bracket (mounted on the product) M12 connector (mounted on the product) Pressure Gauge DS-EC-02-AB03 (3 meter) Declaration of Conformity, containing a link to latest version of this product manual and other relevant product documentation Table 4: Box Items Pressure Gauge 5 of 28 NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 2 GETTING STARTED 2.4 Product Specifications RT Product Product name Type identification Supported sensors Product name Type identification Product name Type identification TWTG NEON Ratiometric Transmitter DS-RT-02-XX TWTG NEON Pressure Sensor DS-PS-02-XX TWTG NEON Pressure Gauge DS-PG-02-XX Environmental conditions Operating temperature range Transmitter
-40C - 70C Storage temperature range Operating humidity range Altitude Water & dust resistance Pollution degree Usage Mechanical Material 10C - 30C 0% - 100% RH Up to 3000 m IP65 3 Indoor and outdoor Molded plastic Weight (including mounting bracket) 330 g Dimensions Installation Transmitter Power Supply specifications Battery rated voltage Battery rated capacity Functional specifications Output Input 100x70x57 mm Band clamp or bolts (not included) 3.6 V 17 Ah LoRaWAN M12 connector (maximum cable length 3 meter) Input insulation rating 500VAC / 1 min Connectivity Protocol Frequency band LoRaWAN 863-870 MHz 902-928 MHz (compatible) Maximum RF output power
+13 dBm Provisioning QR / Serial number NFC Serial number (read only) Serial number (read only) NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 6 of 28 2 GETTING STARTED 2.5 Certifications Certifications ATEX certificate number IECEx certificate number ATEX IECex marking DEKRA 20ATEX0004X IECEx DEK 20.0004X Ex II 1G Ex ia IIC T4 Ga Applicable ATEX/IECEx standards EN 60079-0:2012+A11:2013 FM US certificate number FM CA certificate number US Marking CA Marking IMDA Dealer License CE UKCA WEEE RoHS FCC ISED ICES Manufacturer information Name Address EN 60079-0:2018 EN 60079-11:2012 FM22US0061X FM22CA0043X IS Class I, Division 1, Group ABCD T4 Class I, Zone 0 Ex ia IIC T4 Ga IS Class I, Division 1, Group ABCD T4 Ex II 1G AEx ia IIC T4 Ga DA108442 EN 300 220-1 V3.1.1 EN 300 220-2 V3.2.1 EN 61010-1:2010 + A1:2019 + A1:2019/AC:2019 EN 62311:2020 EN 60529:1911+A1:2000+A2:2013 EN 301 489-1 V2.2.3 EN 301 489-3 V2.1.1 Radio Equipment Regulation 2017 Directive 2033/108/EC 2011/65/EU FCC CFR 47, Part 15, Subpart C FCC CFR 47, Part 15, Subpart B USA FCC Part 15.209, 15.247, 15.205 RSS-247, RSS-Gen CAN ICES-003(B) / NMB-003(B) TWTG R&D BV Schaardijk 386 2909 LA Capelle a/d IJssel The Netherlands Table 5: Product specifications. See also "NEON datasheet" in Related documents for a detailed overview of specifications. 7 of 28 NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 2 GETTING STARTED 2.6 Product Type Identification 2.6.1 NFC The NFC label is located in the identification sticker and programmed with the serial number of the device. The serial number read from the NFC can be used as unique identifyer for provisioning and registration. 2.6.2 Data Matrix Code The Data Matrix Code label also represents the serial number of the device. The serial number read from the QR code can be used as unique identifyer for provisioning and registration. See Serial Number for a detailed label description. Figure 1: NFC and Data Matrix Code code location AA-BB-CC-DD AA - Product Family BB - Product Variant CC - Main Revision DD - Region DS RT = Ratiometric Transmitter E.g. 02 E.g. 00 = Global Table 6: Product Nomenclature AABBCCDDEEFFFFF AA - Product Variant RT = Ratiometric Transmitter BB - Product Revision E.g. 02 CC - Production Year DD - Region EE - Production Batch FFFFF - Serial Number E.g. 23 = 2023 E.g. 00 = Global E.g. AA E.g. 00001 Table 7: Serial Number NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 8 of 28 DS-RT-02-XXCo XX F Lo XX mHPo = XX mWRT022300AA00001Co XX F Lo XX mHPo = XX mW 2.7 Product Dimensions 2 GETTING STARTED Figure 2: Neon Transmitter Dimensions (mm) 9 of 28 NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 Co XX F Lo XX mHPo = XX mW 109 48 84 64 -4,5 CAP 57 3 WARNINGS 3 Warnings 3.1 ATEX / IECEx 3.1.1 Specific Conditions of Use WARNING - POTENTIAL ELECTROSTATIC CHARGING HAZARD The product shall be installed in such a way that the risk for electrostatic discharges is minimised;
When the equipment is used in hazardous locations, avoid any actions which generate electrostatic discharge;
Cleaning: The equipment shall only be cleaned using a wet cloth;
Installation: Touch non-metallic parts with an insulating object;
Environment: Do not use the product in environments with powerful charge generating processes. 3.1.2 Installation This equipment shall be installed according to NEN-EN-IEC 60079-14 and the installation instructions;
This equipment is intended for fixed installations only;
This equipment is intended for use in restricted access areas only. To comply with FCC/IC RF exposure limits for general population / uncontrolled exposure, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. WARNING - DO NOT OPEN WHEN AN EXPLOSIVE ATHMOSPHERE IS PRESENT Under no circumstances shall the equipment enclosure be opened within a hazardous area 3.1.3 Operation The connector of this equipment shall not be connected when an explosive atmosphere is present;
This equipment shall only be used in environments where electromagnetic field strength is limited according to NEN-EN-IEC 60079-14;
This equipment is only intended for use in combination with NFC Forum Tag 2 Type technical specification compatible readers;
This equipment shall only be used within ambient temperatures between -40 C and +70 C. 3.1.4 Service This equipment shall only be opened by TWTG or by a competent instructed person;
The battery is serviceable by said persons;
Only replace the battery in a non-hazardous location;
Only use Tadiran S1P1/SL-2780/323/TWT battery assembly;
Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. If damage to the enclosure is evident, a trained and competent person shall be immediately informed, who shall remove the device from service as soon as possible;
If the equipment is or has been in contact with chemical materials, clean it appropriately. NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 10 of 28 3.1.5 Output parameters The maximum output parameters are limited by the NEON Transmitter. When selecting the sensor to be used with the transmitter, the following values must be taken into account:
3 WARNINGS Figure 3: Intrinsic Safety Limiting Values 3.2 General 3.2.1 Transport and Storage The product must be kept in its original packaging until it reaches the installation site to prevent damage while in transit;
The storage location must be dry;
The product must not be exposed to vibrations or impact during storage. 3.2.2 Warranty The warranty covers the period noted on the quotation;
If the device doesnt function as documented, the customer should contact TWTG and provide the following information;
Model specification;
Serial number;
Circumstances under which the problems developed;
Any previously generated data;
The party responsible for the costs of solving the problem shall be determined by TWTG on the basis of an investigation conducted by TWTG. 3.2.3 Warranty will be void in case of Malfunction due to ignoring the design specifications;
Malfunction due to modification of the product carried out by the user;
Deferred maintenance of the product or the installation location. 11 of 28 NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 234Ratiometric TransmitterUo = 3.98 VIo = 1328 mAPo = 472 mWCo = 26 uFLo = 10 uH1234NEON TransmitterSimple apparatus Uo < Ui, Io < Ii, Po < Pi, Co > Ci, Lo > LiControl drawingUo = 5.73 VIo = 46 mAPo = 263 mWCo = 3 uFLo = 5 uHCi = 4 uFLi = 0 uH 4 AVERTISSEMENTS 4 Avertissements 4.1 ATEX / IECEx 4.1.1 Conditions spcifiques dutilisation ATTENTION RISQUE POTENTIEL DE DECHARGES ELECTROSTATIQUES Le produit doit obligatoirement tre install de manire minimiser le risque de dcharges lectrostatiques;
Lorsque lquipement est utilis dans un environnement dangereux, vitez strictement toute action gnrant une dcharge lectrostatique;
Nettoyage: Lquipement doit tre nettoy uniquement laide dun chiffon humide;
Installation: Toucher les parties non mtalliques quavec un objet isolant;
Environnement: Nutilisez pas le produit dans des environnements gnrant de fortes charges dlectricit. 4.1.2 Installation Cet quipement doit tre install conformment la norme NEN-EN-IEC 60079-14 et aux instructions dinstallation;
Cet quipement est uniquement destin aux installations fixes;
Cet quipement est uniquement destin tre utilis dans des zones accs restreint. ATTENTION NE PAS OUVRIR DANS UNE ATMOSPHRE EXPLOSIVE Le botier de lquipement ne doit en aucun cas tre ouvert dans une zone dangereuse. 4.1.3 Fonctionnement Le connecteur de cet quipement ne doit tre utilis quavec un quipement externe tel quindiqu dans le "product matrix";
Le connecteur de cet quipement ne doit jamais tre connect dans une atmosphre explosive;
Cet quipement ne doit tre utilis que dans un environnement o lintensit du champ magntique est limite conformment la norme EN 60079-14;
Cet quipement est uniquement destin tre utilis en combinaison avec des lecteurs compatibles dont les spcifications techniques respectent la norme des tags NFC de Type 2;
Cet quipement ne doit tre utilis qu des tempratures comprises entre -40 C et +70 C. 4.1.4 Entretien Cette pice dquipement ne doit tre ouverte que par TWTG ou par une personne comptente et selon le guide dutilisation;
La batterie peut tre mise neuf par ces personnes;
Ne remplacez la batterie que dans un endroit sans danger;
Utilisez uniquement lensemble de batterie Tadiran S1P1/SL-2780/323/TWT ;
Si le botier est endommag, informez immdiatement une personne comptente pour quelle vienne rcuprer lquipement;
Si lquipement est (ou a t) en contact avec des substances chimiques, nettoyez-le de manire approprie. NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 12 of 28 4.1.5 Output parameters The maximum output parameters are limited by the NEON Transmitter. When selecting the sensor to be used with the transmitter, the following values must be taken into account:
4 AVERTISSEMENTS Figure 4: Intrinsic Safety Limiting Values 4.2 Informations gnrales 4.2.1 Transport et stockage Le produit doit tre conserv dans son emballage jusqu ce quil atteigne le site dinstallation pour viter tout dommage pendant le transit;
Le lieu de stockage doit tre sec;
Lappareil ne doit pas tre expos des vibrations ou des chocs pendant le transport et le stockage. 4.2.2 Garantie La garantie couvre la priode indique sur le devis;
Si lappareil ne fonctionne pas comme prvu, le client doit contactez TWTG et fournir les lments suivants;
Spcifications du modle;
Numro de srie;
Les circonstances dans lesquelles les problmes sont survenus;
Toutes les donnes prcdemment gnres;
La partie responsable des cots de rsolution du problme sera dtermine par TWTG sur la base dune enqute prive mene par TWTG. 4.2.3 La garantie sera annule dans les cas suivants:
Non-respect des spcifications du modle;
Modification du produit effectue par lutilisateur;
Entretient non conforme aux spcifications du produit;
Utilisation dans un endroit non conforme aux spcifications. 13 of 28 NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 234Ratiometric TransmitterUo = 3.98 VIo = 1328 mAPo = 472 mWCo = 26 uFLo = 10 uH1234NEON TransmitterSimple apparatus Uo < Ui, Io < Ii, Po < Pi, Co > Ci, Lo > LiControl drawingUo = 5.73 VIo = 46 mAPo = 263 mWCo = 3 uFLo = 5 uHCi = 4 uFLi = 0 uH 5 PROVISIONING 5 Provisioning 5.1 User Interface The product contains one Light Emitting Diode (LED) to communicate with the user. In order to interact with the device a button is present on the right side of the NFC label. Figure 5: NEON Ratiometric Transmitter Interface 5.2 Operating the Device 5.2.1 Read device status Press and Release Press and Hold Release Green Activated Red Deactivated White Connected White Blinking Connecting 1. Press and Release the button button:
2.1 Green: Device is activated 2.2 Red: Device is deactivated NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 14 of 28 LEDButtonCo XX F Lo XX mHPo = XX mW 5.2.2 Device Activation 5 PROVISIONING Press and Release Press and Hold Release Green Activated Red Deactivated White Connected White Blinking Connecting 1. Press & hold the button and the device will immediately show its status:
2.1 Red: Deactivated, or 2.2 Green: Already Activated Note: Release the button if its already activated otherwise the deactivation procedure will start. 3. Hold the button for 5 more seconds to start activation:
4. Blinking White: Connecting to the Network 5. Within a typical maximum of 3 minutes* the device will show:
5.1 White: Sending activation message, or 5.2 Red: Network failure 6. Within a typical maximum of 3 minutes* the device will show:
6.1 Green: Activation succeeded, or 6.2 Red: Network failure Notes:
*All timeout and retry values are valid for the default configuration, the maximum timeout might be longer when process is performed repeatedly due to RF duty cycle limitations. 15 of 28 NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 5 PROVISIONING 5.2.3 Device Deactivation Press and Release Press and Hold Release Green Activated Red Deactivated White Connected White Blinking Connecting 1. Press and hold the button, the device will show:
2.1 Green: Activated 2.2 Red: Already Deactivated, or Note: Release the button if it is already deactivated otherwise the activation procedure will start. Hold the button for 5 more seconds if the device is activated:
3. Red: Deactivation Succeeded NOTE: The deactivation procedure will always succeed. An attempt for sending a status message will be performed. This will not be shown as blinking white LED. NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 16 of 28 6 INSTALLATION 6 Installation 6.1 Precautions WARNING Avoid placing wiring close to noise sources such as large motors or power supplies;
To comply with FCC/IC RF exposure limits for general population / uncontrolled exposure, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter;
Only connect the M12 connector to the Ratiometric Transmitter when there is no explosive atmosphere present;
The equipment must be installed in accordance with EN 60079-14. 6.2 Mounting Bracket Dimensions Figure 6: Product Dimensions 17 of 28 NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 8 22 25,5 4,4 74 6 INSTALLATION 6.3 Installation Methods 6.3.1 Installation using mounting holes Place the bracket against the (flat) desired surface and use the screw holes or slots to fix in place. Note: Slots and screw holes are designed for M4 fasteners. 6.3.2 Installation using threaded holes Note: Threaded hole accepts M5 bolts.
(a) Mounting holes
(b) Threaded mounting holes 6.3.3 Installation using bandclamp The Neon Ratiometric Transmitter can be mounted to a pole using a 14 mm wide band clamp, other sizes are not recommended. Procedure:
1. Place the band clamp through the bracket;
2. Place the band clamp around the pole and cut to size;
3. Place the band clamp through the adjustable tightener and fold around the bottom with a plier;
4. Place the band clamp around the pole with the (adjustable) tightener and fix it in place. Figure 8: Installation using bandclamp NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 18 of 28 Co XX F Lo XX mHPo = XX mW 7 PRODUCT FUNCTIONALITIES 7 Product Functionalities A detailled description of setting-up communication and configuring device settings can be found in "Communication protocol", refer to table 2. Related documents. 7.1 Application Event Message The Ratiometric Transmitter measures and reports the pressure either by set intervals (a timer-based trigger) or a condition-based trigger.
[C]
Trigger Trigger Above Increasing Decreasing Time Trigger Trigger Below Figure 9: Application trigger event message 7.1.1 Event-triggers Event-messages are triggered on one of the following triggers. Timer (periodic):
The timer trigger is configurable through the following configurations:
pressure_measurement_interval_seconds Interval in seconds, at which the pressure sensor is read. periodic_event_message_interval Interval in the number of measurements at which the application event messages are periodically sent. The periodic counter is reset on every event message. Condition:
A condition-based trigger can be either of the following triggers:
Above If the maximum pressure is above the pressure_threshold then the condition is true. A transition of the condition from false to true or true to false will trigger an event message. 19 of 28 NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 7 PRODUCT FUNCTIONALITIES Below If the minimum pressure is below the pressure_threshold then the condition is true. A transition of the condition from false to true or true to false will trigger an event message. Increasing The condition is true when the current pressure is at least pressure_threshold higher than the minimum pressure in the measurement_window (The maximum number of measurements to observe delta pressure to trigger an event). A transition of the condition from false to true or true to false will trigger an event message. Decreasing The condition is true when the current pressure is at least pressure_threshold lower than the maximum pressure in the measurement_window (The maximum number of measurements to observe delta pressure to trigger an event). A transition of the condition from false to true or true to false will trigger an event message. 7.1.2 Content application event message Pressure The connected sensor pressure in units of 0-365.6 PDI (0-25 Bar):
Maximal;
Average;
Minimal. Trigger Source of the trigger for the application event message:
"timer" (0);
"condition_0" (1);
"condition_1" (2);
"condition_2" (3);
"condition_3" (4). condition_n The current state of each condition. 7.2 Device Status Besides reporting the application pressure as discussed previously, the Ratiometric Transmitter also reports on the device status itself. This is done through a device status messages. A device status message is sent periodically and includes a range of device health parameters, including the following:
event_counter;
battery_voltage;
PCB temperature;
tx_counter;
avg_rssi;
avg_snr. See "Communication Protocol" in Related documents for a detailed explanation. 7.3 Default Configuration The Ratiometric Transmitter is delivered with a default configuration. The default configuration includes:
Measurement interval of 15 mins;
Event-based message at the time of each periodic trigger with an interval of 15 measurements. (15 * 15 = 225 mins);
Device status message interval of 24 hours;
Enabled confirmation message on all messages. See "Communication Protocol" in Related documents for a detailed explanation of all default configuration values. NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 20 of 28 8 MAINTENANCE 8 Maintenance 8.1 Battery Specifications Specifications Manufacturer Part number Quantity Battery Type / Size Chemistry Terminal Type Dimensions Battery Life Tadiran Tadiran S1P1/SL-2780/323/TWT 1 Type D Lithium Thionyl Chloride Standard 61 x 32.5 mm
>7 years*
Table 8: Battery Specifications
*Note: Applicable to default configuration. Battery lifetime depends on average ambient temperature, network quality and device configuration. 8.1.1 Battery Replacement The battery can be replaced using the battery replacement kit. See Accessories and Spare Parts. This kit consists of the following parts:
1X Tadiran S1P1/SL-2780/323/TWT 4X O-Ring 1X Gasket 8.1.2 Required tools Torque screwdriver with TX10 bit;
See Assembly of device for torque settings;
ESD strap. IMPORTANT: ESD Sensitive Electronics The product shall be installed in such a way that the risk for electrostatic discharges is minimised. Take proper precaution such as a grounded wrist strap and avoid touching the electronics board 21 of 28 NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 8 MAINTENANCE 8.1.3 Disassembly of device WARNING - DO NOT OPEN WHEN AN EXPLOSIVE ATHMOSPHERE IS PRESENT This equipment shall only be opened by TWTG or by a competent instructed person;
The battery is serviceable by said persons;
Always disconnect M12 connector from Transmitter before replacing battery assembly Step 1: Remove the four M3 screws and remove the bottom Step 2: Before removing the battery assembly, disconnect the housing battery connector (marked in red) Step 3: Place the new battery assembly. Use the rib on the battery cradle (marked in red) to align with designated cut out in top housing and connect the new battery connector NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 22 of 28 Align 8.1.4 Built-In Self-Test Procedure When the device is deactivated a built-in self-test is performed upon insertion of the battery. This test is not executed when the device is already activated. Use the deactivation sequence as described in Device Deactivation and reinsert the batteries if a self-test is needed. 8 MAINTENANCE Figure 10: Built-in self-test 1: After successful replacement of the battery the device will go into self test mode. This mode is activated for 30 seconds;
1.1: A BLUE LED will show after inserting the battery;
1.2: If no LED is shown, check the battery and / or device;
2: Start the test;
2.1: Press and Release the button;
3: Test Results;
3.1: LED turns bright WHITE for 5 seconds. Self test passed;
3.2: LED turns RED, self test failed. Check device;
3.3: No LED, no response from device. Check device. After pressing the button once and passing the self-test the device will leave the self-test mode. Pressing the button again will show the device status, as explained in Read device status. 23 of 28 NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 8 MAINTENANCE 8.1.5 Assembly of device IMPORTANT - USE THE SPECIFIED TORQUE SETTINGS Use a torque screwdriver to verify the applied torque;
Failure to do so can result in water ingress;
Improper assembly will void the warranty. Step 4: Replace the 4 o-rings surrounding the screws and the gasket in the outer edge of the bottom housing Step 5: Place the bottom housing back onto the top housing. For correct orientation; Make sure that the bottom housing grounding plate is aligned with the top housing M12 connector Step 6: Tighten the four M3 screws to fix the bottom housing. Use a torque screwdriver to set the maximum torque to 1 Nm NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 24 of 28 Align 9 ACCESSORIES AND SPARE PARTS 9 Accessories and Spare Parts Type Order code Description Battery Replacement Kit 5029_N02-09_Battery-
Replacement-Kit RT Sensor cable DS-EC-02-AB03 Including 1 battery assembly, 4 O-Rings, 1 gasket Table 9: Available Accessories & Spare Parts 25 of 28 NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 10 EU DECLARATION OF CONFORMITY 10 EU Declaration of Conformity This product complies with the following standards:
1. ATEX Directive (2014/34/EU):
EN 60079-0:2012 +A11:2013 EN 60079-0:2018 EN 60079-11:2012 2. Radio Equipment Directive (2014/53/EU):
EN 300 220-1 V3.1.1 EN 300 220-2 V3.2.1 EN 301 489-1 V2.2.3 EN 301 489-3 V2.1.1 EN 61010-1:2010 + A1:2019 + A1:2019/AC:2019 EN 62311:2020 EN 60529:1991 + A1:2000 + A2:2013 3. WEEE Directive 2003/1008/EC 4. RoHS (2011/65/EU) For the full Declaration of Conformity see:
www.twtg.io/legal NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 26 of 28 11 FCC AND ISED DECLARATIONS 11 FCC and ISED Declarations This device complies with part 15 of the FCC Rules and to RSS of Industry Canada. Operation is subject to the following two conditions:
1. this device may not cause harmful interference, and 2. this device must accept any interference received, including interference that may cause undesired operation. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
1. lappareil ne doit pas produire de brouillage, et 2. lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numrique de Classe B est conforme la norme Canadienne ICES-003. CAN ICES-003(B) / NMB-003(B) 27 of 28 NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 Revision History Revision Date A1 A2 28-10-2022 24-11-2022 WK Author(s) SvW Description Concept version Updated FCC/ISED declaration NEON-Ratiometric-Transmitter_User-Manual_DS-RT-02-xx_4001_A2 28 of 28
1 2 | Users Manual Temperature Transmitter | Users Manual | 2.56 MiB | December 16 2022 / March 01 2023 | delayed release |
Temperature Transmitter Product Manual This document applies to version 2 of the NEON Temperature Transmitter (DS-TT-02-XX) NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 Version A3 24-11-2022 Contents 1 TWTG NEON 1.1 NEON Product Introduction . 1.2 Related Documents . 2 Getting Started 2.1 Compatibility of this manual
. 2.2 What you will need . 2.3 What is in the box . 2.4 Product Specifications . 2.5 Product Type Identification . 2.6 Component Names
. 2.7 Product Dimensions . 4 4 4 5 5 5 5 6 8 9 9 3 Warnings 10 3.1 ATEX / IECEx . 10 3.1.1 Specific Conditions of Use . 10 3.1.2 Installation . 10 3.1.3 Operation . 10 3.1.4 Service . 10 3.1.5 Output parameters . 11 3.2 General . 11 3.2.1 Transport and Storage . 11 3.2.2 Warranty . 11
. 11 3.2.3 Warranty will be void in case of 4 Avertissements 12 4.1 ATEX / IECEx . 12 4.1.1 Conditions spcifiques dutilisation . 12 4.1.2 Installation . 12 4.1.3 Fonctionnement
. 12 4.1.4 Entretien . 12 4.1.5 Output parameters . 13 4.2 Informations gnrales . 13 4.2.1 Transport et stockage . 13 4.2.2 Garantie . 13
. 13 4.2.3 La garantie sera annule dans les cas suivants:
5 Provisioning 14 5.1 User Interface . 14 5.2 Operating the Device . 15 5.2.1 Read device status . 15 5.2.2 Device Activation . 16 5.2.3 Device Deactivation . 17 5.3 Product Identification . 18 5.3.1 NFC . 18 5.3.2 Data Matrix Code . 18 NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 2 of 34 CONTENTS 6 Installation 19
. 19 6.1 Precautions 6.2 Mounting Bracket Dimensions . 19 6.3 Installation Methods . 20 6.3.1 Installation using mounting holes . 20 6.3.2 Installation using threaded holes . 20 6.3.3 Installation using bandclamp . 21 6.4 Using the Temperature Transmitter with Thermocouples . 22 6.4.1 Cold Junction Compensation . 22 6.4.2 Assessed Connectors . 22 6.4.3 Selecting a thermocouple wire . 22 6.4.4 Connecting a thermocouple wire to the temperature interface . 23
. 24 6.5.1 Connecting a RTD (3-wire) sensor to the temperature interface . 24 6.5 Using the Temperature Transmitter with a RTD (3-wire) 7 Product Functionalities 25 7.1 Application Event Message . 25 7.1.1 Event-triggers
. 25 7.1.2 Content application event message . 26 7.2 Device Status
. 26 7.3 Default Configuration . 26 8 Maintenance 27 8.1 Battery Specifications . 27 8.1.1 Battery Replacement . 27 8.1.2 Required tools . 27 8.1.3 Disassembly of device . 28 8.1.4 Built-In Self-Test Procedure . 29 8.1.5 Assembly of device . 30 9 Accessories and Spare Parts 10 EU Declaration of Conformity 11 FCC and ISED Declarations 31 32 33 3 of 34 NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 1 TWTG NEON 1 TWTG NEON 1.1 NEON Product Introduction NEON stands for a standardised approach to collecting data points from the operational environment and in doing so, creates a general approach to integrated data collection within existing IT ecosystems. The TWTG NEON product range supports all industrial customers moving towards LoRaWAN as the Industrial IoT network of the future. The LoRaWAN network gives industrial operations a secure solution, which scales-up to tens of thousands of sensors, covers complete sites with only a small amount of gateways and best of all the low-power approach means that the lifetime of the NEON products is extended dramatically. 1.2 Related Documents Document Name NEON Data Sheet Document Number 6015_N02-09_Data-Sheet-NEON-Temperature-Transmitter NEON Communication Protocol 6020_N02-09_Communication-Protocol-NEON-Temperature-Transmitter Table 1: Related documents NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 4 of 34 2 GETTING STARTED 2 Getting Started 2.1 Compatibility of this manual This manual is meant to be used with products of from a specific production batch. See Serial Number for an explanation on how to retrieve the production batch code from the serial number. This manual is applicable to version 2 of the NEON Temperature Transmitter. See chapter Product Type Identification to determine the revision of the product. 2.2 What you will need In order to deploy the NEON Temperature Transmitter, a compatible and operational LoRaWAN network architecture is required. This manual does not contain any instructions of how to setup and install LoRaWAN networks. TWTG offers radio network planning and IT-architecture design services to fully integrate the products in the NEON product line. 2.3 What is in the box When the product is delivered check the components for damage and whether all box items mentioned below are included. Box Items NEON Temperature Transmitter 1 battery assembly (included in the product) 1 mounting bracket (mounted on the product) M12 connector (mounted on the product) Declaration of Conformity Declaration of Conformity, containing a link to latest version of this product manual and other relevant product documentation Table 2: Box Items 5 of 34 NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 2 GETTING STARTED 2.4 Product Specifications Product Product name Type identification TWTG NEON Temperature Transmitter DS-TT-02-XX Supported temperature sensors Thermocouple Type-K (other types configurable over LoRa) Environmental conditions Operating temperature range Transmitter
-40C - 70C RTD PT100 Storage temperature range Operating humidity range Altitude Water & dust resistance Pollution degree Usage Mechanical Material 10C - 30C 0% - 100% RH Up to 3000 m IP65 3 Indoor and outdoor Molded plastic Weight (including mounting bracket) 330 g Dimensions Installation Transmitter Maximum cable length Power Supply specifications Battery rated voltage Battery rated capacity Functional specifications Output Input 100x70x57 mm Band clamp or bolts (not included) Limited by equipment output parameters, thermocouple wire see Selecting a 3.6 V 17 Ah LoRaWAN M12 connector for thermocouple or RTD input Input insulation rating 500VAC / 1 min Connectivity Protocol Frequency band LoRaWAN 863-870 MHz 902-928 MHz (compatible) Maximum RF output power
+13 dBm Provisioning QR / Serial number NFC Serial number (read only) Serial number (read only) NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 6 of 34 2 GETTING STARTED Certifications ATEX certificate number IECEx certificate number ATEX IECex marking Applicable ATEX/IECEx standards FM US certificate number FM CA certificate number US Marking CA Marking IMDA Dealer License CE UKCA FCC ISED ICES Manufacturer information Name Address DEKRA 20ATEX0004X IECEx DEK 20.0004X Ex II 1G Ex ia IIC T4 Ga EN 60079-0 EN 60079-11 FM22US0061X FM22CA0043X IS Class I, Division 1, Group ABCD T4 Class I, Zone 0 Ex ia IIC T4 Ga IS Class I, Division 1, Group ABCD T4 Ex II 1G AEx ia IIC T4 Ga DA108442 EN 300 220-1 EN 300 220-2 EN 61010-1:2010 + A1:2019 + A1:2019/AC:2019 EN 62311 EN 60529 EN 301 489-1 EN 301 489-3 Radio Regulation 2017 FCC CFR 47, Part 15, Subpart C FCC CFR 47, Part 15, Subpart B USA FCC Part 15.209, 15.247, 15.205 RSS-247, RSS-Gen CAN ICES-003(B) / NMB-003(B) TWTG R&D BV Schaardijk 386 2909 LA Capelle a/d IJssel The Netherlands Table 3: Product specifications. See also "NEON datasheet" in Related documents for a detailed overview of specifications. 7 of 34 NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 2 GETTING STARTED 2.5 Product Type Identification AA-BB-CC-DD AA - Product Family BB - Product Variant CC - Main Revision DD - Region Figure 1: Example Drawing "Front Panel"
DS TT = Temperature Transmitter E.g. 02 E.g. 00 = Global Table 4: Product Nomenclature AABBCCDDEEFFFFF AA - Product Variant TT = Temperature Transmitter BB - Product Revision E.g. 02 CC - Production Year DD - Region EE - Production Batch FFFFF - Serial Number E.g. 22 = 2022 E.g. 00 = Global E.g. AA E.g. 00001 Table 5: Serial Number NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 8 of 34 DS-TT-02-00Co 80 F Lo 10 mHPo = 44 mWTT022002AA00001 2.6 Component Names 2 GETTING STARTED Figure 2: Component Names Description Neon Transmitter Data Matrix Code NFC Mounting Bracket M12 Connector Dust Cap Table 6: Component Names Number 1 2 3 4 5 2.7 Product Dimensions Figure 3: Neon Transmitter Dimensions (mm) 9 of 34 NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 32514 114 48 84 64 -4,5 CAP 57 3 WARNINGS 3 Warnings 3.1 ATEX / IECEx 3.1.1 Specific Conditions of Use WARNING - POTENTIAL ELECTROSTATIC CHARGING HAZARD The product shall be installed in such a way that the risk for electrostatic discharges is minimised;
When the equipment is used in hazardous locations, avoid any actions which generate electrostatic discharge;
Cleaning: The equipment shall only be cleaned using a wet cloth;
Installation: Touch non-metallic parts with an insulating object;
Environment: Do not use the product in environments with powerful charge generating processes. 3.1.2 Installation This equipment shall be installed according to NEN-EN-IEC 60079-14 and the installation instructions;
This equipment is intended for fixed installations only;
This equipment is intended for use in restricted access areas only. To comply with FCC/IC RF exposure limits for general population / uncontrolled exposure, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. WARNING - DO NOT OPEN WHEN AN EXPLOSIVE ATHMOSPHERE IS PRESENT Under no circumstances shall the equipment enclosure be opened within a hazardous area 3.1.3 Operation The connector of this equipment shall not be connected when an explosive atmosphere is present;
The thermocouple or RTD shall either be earthed or have an infallible isolation to earth with an dielectric strength of 500 VAC/1minute or greater;
This equipment shall only be used in environments where electromagnetic field strength is limited according to NEN-EN-IEC 60079-14;
This equipment is only intended for use in combination with NFC Forum Tag 2 Type technical specification compatible readers;
This equipment shall only be used within ambient temperatures between -40 C and +70 C. 3.1.4 Service This equipment shall only be opened by TWTG or by a competent instructed person;
The battery is serviceable by said persons;
Only replace the battery in a non-hazardous location;
Only use Tadiran S1P1/SL-2780/323/TWT battery assembly;
Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. If damage to the enclosure is evident, a trained and competent person shall be immediately informed, who shall remove the device from service as soon as possible;
If the equipment is or has been in contact with chemical materials, clean it appropriately. NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 10 of 34 3.1.5 Output parameters The maximum output parameters are limited by the NEON Transmitter. When selecting the temperature sensor to be used with the transmitter, the following values must be taken into account:
3 WARNINGS Figure 4: Intrinsic Safety Limiting Values 3.2 General 3.2.1 Transport and Storage The product must be kept in its original packaging until it reaches the installation site to prevent damage while in transit;
The storage location must be dry;
The product must not be exposed to vibrations or impact during storage. 3.2.2 Warranty The warranty covers the period noted on the quotation;
If the device doesnt function as documented, the customer should contact TWTG and provide the following information;
Model specification;
Serial number;
Circumstances under which the problems developed;
Any previously generated data;
The party responsible for the costs of solving the problem shall be determined by TWTG on the basis of an investigation conducted by TWTG. 3.2.3 Warranty will be void in case of Malfunction due to ignoring the design specifications;
Malfunction due to modification of the product carried out by the user;
Deferred maintenance of the product or the installation location. 11 of 34 NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 234Temperature TransmitterUo = 3.98 VIo = 1328 mAPo = 472 mWCo = 26 uFLo = 10 uH1234NEON TransmitterSimple apparatus Uo < Ui, Io < Ii, Po < Pi, Co > Ci, Lo > LiControl drawingUo = 3.98 VIo = 44 mAPo = 44 mWCo = 80 uFLo = 10 mHCi = 4 uFLi = 0 uH 4 AVERTISSEMENTS 4 Avertissements 4.1 ATEX / IECEx 4.1.1 Conditions spcifiques dutilisation ATTENTION RISQUE POTENTIEL DE DECHARGES ELECTROSTATIQUES Le produit doit obligatoirement tre install de manire minimiser le risque de dcharges lectrostatiques;
Lorsque lquipement est utilis dans un environnement dangereux, vitez strictement toute action gnrant une dcharge lectrostatique;
Nettoyage: Lquipement doit tre nettoy uniquement laide dun chiffon humide;
Installation: Toucher les parties non mtalliques quavec un objet isolant;
Environnement: Nutilisez pas le produit dans des environnements gnrant de fortes charges dlectricit. 4.1.2 Installation Cet quipement doit tre install conformment la norme NEN-EN-IEC 60079-14 et aux instructions dinstallation;
Cet quipement est uniquement destin aux installations fixes;
Cet quipement est uniquement destin tre utilis dans des zones accs restreint. ATTENTION NE PAS OUVRIR DANS UNE ATMOSPHRE EXPLOSIVE Le botier de lquipement ne doit en aucun cas tre ouvert dans une zone dangereuse. 4.1.3 Fonctionnement Le connecteur de cet quipement ne doit tre utilis quavec un quipement externe tel quindiqu dans le "product matrix";
Le connecteur de cet quipement ne doit jamais tre connect dans une atmosphre explosive;
Le thermocouple ou le dtecteur de temprature rsistance doit tre mis la terre ou avoir une isolation absolue avec une rigidit dilectrique de 500 V/1 minute ou plus;
Cet quipement ne doit tre utilis que dans un environnement o lintensit du champ magntique est limite conformment la norme EN 60079-14;
Cet quipement est uniquement destin tre utilis en combinaison avec des lecteurs compatibles dont les spcifications techniques respectent la norme des tags NFC de Type 2;
Cet quipement ne doit tre utilis qu des tempratures comprises entre 40 C et 70 C. 4.1.4 Entretien Cette pice dquipement ne doit tre ouverte que par TWTG ou par une personne comptente et selon le guide dutilisation;
La batterie peut tre mise neuf par ces personnes;
Ne remplacez la batterie que dans un endroit sans danger;
Utilisez uniquement lensemble de batterie Tadiran S1P1/SL-2780/323/TWT ;
Si le botier est endommag, informez immdiatement une personne comptente pour quelle vienne rcuprer lquipement;
Si lquipement est (ou a t) en contact avec des substances chimiques, nettoyez-le de manire approprie. NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 12 of 34 4.1.5 Output parameters The maximum output parameters are limited by the NEON Transmitter. When selecting the temperature sensor to be used with the transmitter, the following values must be taken into account:
4 AVERTISSEMENTS Figure 5: Intrinsic Safety Limiting Values 4.2 Informations gnrales 4.2.1 Transport et stockage Le produit doit tre conserv dans son emballage jusqu ce quil atteigne le site dinstallation pour viter tout dommage pendant le transit;
Le lieu de stockage doit tre sec;
Lappareil ne doit pas tre expos des vibrations ou des chocs pendant le transport et le stockage. 4.2.2 Garantie La garantie couvre la priode indique sur le devis;
Si lappareil ne fonctionne pas comme prvu, le client doit contactez TWTG et fournir les lments suivants;
Spcifications du modle;
Numro de srie;
Les circonstances dans lesquelles les problmes sont survenus;
Toutes les donnes prcdemment gnres;
La partie responsable des cots de rsolution du problme sera dtermine par TWTG sur la base dune enqute prive mene par TWTG. 4.2.3 La garantie sera annule dans les cas suivants:
Non-respect des spcifications du modle;
Modification du produit effectue par lutilisateur;
Entretient non conforme aux spcifications du produit;
Utilisation dans un endroit non conforme aux spcifications. 13 of 34 NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 234Temperature TransmitterUo = 3.98 VIo = 1328 mAPo = 472 mWCo = 26 uFLo = 10 uH1234NEON TransmitterSimple apparatus Uo < Ui, Io < Ii, Po < Pi, Co > Ci, Lo > LiControl drawingUo = 3.98 VIo = 44 mAPo = 44 mWCo = 80 uFLo = 10 mHCi = 4 uFLi = 0 uH 5 PROVISIONING 5 Provisioning 5.1 User Interface The product contains one Light Emitting Diode (LED) to communicate with the user. In order to interact with the device a button is present on the right side of the NFC label. Figure 6: NEON Temperature Transmitter Interface NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 14 of 34 LEDButton 5.2 Operating the Device 5.2.1 Read device status 5 PROVISIONING Press and Release Press and Hold Release Green Activated Red Deactivated White Connected White Blinking Connecting 1. Press and Release the button button:
2.1 Green: Device is activated 2.2 Red: Device is deactivated 15 of 34 NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 5 PROVISIONING 5.2.2 Device Activation Press and Release Press and Hold Release Green Activated Red Deactivated White Connected White Blinking Connecting 1. Press & hold the button and the device will immediately show its status:
2.1 Red: Deactivated, or 2.2 Green: Already Activated Note: Release the button if its already activated otherwise the deactivation procedure will start. 3. Hold the button for 5 more seconds to start activation:
4. Blinking White: Connecting to the Network 5. Within a typical maximum of 3 minutes* the device will show:
5.1 White: Sending activation message, or 5.2 Red: Network failure 6. Within a typical maximum of 3 minutes* the device will show:
6.1 Green: Activation succeeded, or 6.2 Red: Network failure Notes:
*All timeout and retry values are valid for the default configuration, the maximum timeout might be longer when process is performed repeatedly due to RF duty cycle limitations. NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 16 of 34 5.2.3 Device Deactivation 5 PROVISIONING Press and Release Press and Hold Release Green Activated Red Deactivated White Connected White Blinking Connecting 1. Press and hold the button, the device will show:
2.1 Green: Activated 2.2 Red: Already Deactivated, or Note: Release the button if it is already deactivated otherwise the activation procedure will start. Hold the button for 5 more seconds if the device is activated:
3. Red: Deactivation Succeeded NOTE: The deactivation procedure will always succeed. An attempt for sending a status message will be performed. This will not be shown as blinking white LED. 17 of 34 NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 5 PROVISIONING 5.3 Product Identification 5.3.1 NFC The NFC label is located in the identification sticker and programmed with the serial number of the device. The serial number read from the NFC can be used as unique identifyer for provisioning and registration. 5.3.2 Data Matrix Code The Data Matrix Code label also represents the serial number of the device. The serial number read from the QR code can be used as unique identifyer for provisioning and registration. See Serial Number for a detailed label description. Figure 7: NFC and Data Matrix Code code Location NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 18 of 34 DS-TT-02-00Co 80 F Lo 10 mHPo = 44 mWTT022002AA00001 6 INSTALLATION 6 Installation 6.1 Precautions WARNING Avoid placing wiring close to noise sources such as large motors or power supplies;
To comply with FCC/IC RF exposure limits for general population / uncontrolled exposure, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter;
Only connect the M12 connector to the Temperature Transmitter when there is no explosive atmosphere present;
The equipment must be installed in accordance with EN 60079-14. 6.2 Mounting Bracket Dimensions Figure 8: Product Dimensions 19 of 34 NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 8 22 25,5 4,4 74 6 INSTALLATION 6.3 Installation Methods 6.3.1 Installation using mounting holes Place the bracket against the (flat) desired surface and use the screw holes or slots to fix in place. Note: Slots and screw holes are designed for M4 fasteners. Figure 9: Product Mounting Holes 6.3.2 Installation using threaded holes Note: Threaded hole accepts M5 bolts. Figure 10: Product Threaded Mounting Holes NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 20 of 34 6.3.3 Installation using bandclamp The Neon Temperature Transmitter can be mounted to a pole using a 14 mm wide band clamp, other sizes are not recommended. 6 INSTALLATION Procedure:
1. Place the band clamp through the bracket;
2. Place the band clamp around the pole and cut to size;
3. Place the band clamp through the adjustable tightener and fold around the bottom with a plier;
4. Place the band clamp around the pole with the (adjustable) tightener and fix it in place. Figure 11: Installation using bandclamp 21 of 34 NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 6 INSTALLATION 6.4 Using the Temperature Transmitter with Thermocouples 6.4.1 Cold Junction Compensation The interface to the NEON Temperature Transmitter uses an M12 connector with Type-A polarisation. This interface can be used for reading out both thermocouples and RTDs. For use with thermocouples the Temperature Transmitter has a built-in cold junction compensation (CJC):
Figure 12: CJC Section Overview The temperature transmitter uses the copper pins of the M12 connector as the cold junction, as seen in figure 12. CJC Section Overview. The cold junction compensation uses the temperature of the copper contacts as measured by the internal reference temperature sensor. The internal reference temperature is directly in thermal contact with the cold junction. 6.4.2 Assessed Connectors The following connectors have been assessed by TWTG and can be used in combination with the Neon Transmitter:
Manufacturer Part Number Type Phoenix Contact Phoenix Contact 1424656 1424655 Push-in, metal, right angle (female) connector Push-in, metal, straight (female) connector Table 7: Compatible M12 connectors 6.4.3 Selecting a thermocouple wire A suitable thermocouple wire needs to be assessed as simple apparatus and needs to be assessed as safe with regards to thermal and spark ignition. NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 22 of 34 CJCCJ 6 INSTALLATION Select a cable with cross section of 0.14mm2 to 0.75mm2 with a round outer shell with a diameter of 4 to 8 mm. the sensor is mounted in a noisy environment a shielded cable can be used. If WARNING Do not connect the shield to the M12 connector shield to prevent a multi-point ground, only connect the shield at the thermocouple junction. Use the values as listed in table 8 to determine compliance. The maximum permitted cable length is determined by cable Li and Ci and limited to the maximum installation cable length of 3 meters. Limiting Value 100 F 10 mH 37 mW 3.9 V Co Lo Po Uo Thermocouple wire requirements Ci < Co Li < Lo Assess heat-up of cable with Po and Uo parameters for all lengths between 0 meter and required cable length Assess heat-up of cable with Po and Uo parameters for all lengths between 0 meter and required cable length Table 8: Thermocouple limiting values 6.4.4 Connecting a thermocouple wire to the temperature interface
(a) Open the locking lever and insert wire
(b) Connector with levers closed Figure 13: Cable connection example Pin Pin 1 Pin 2 Pin 3 Pin 4 Connection Not used Thermocouple Positive Connection Thermocouple Negative Connection Not used Table 9: Thermocouple pinout 1. Strip the wires down by 7mm;
2. Insert the cable through the waterproofing O-Ring and cable gland nut;
23 of 34 NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 12123 6 INSTALLATION 3. Open the locking lever of the push in connector;
4. Press the thermocouple wire in the connector, use table. 9 to verify polarity. Do not use excessive force;
Ensure the correct polarity, as the device will not function properly with reversed polarity;
5. Close the locking lever of the push in connector;
6. Tighten the nut with the O-Ring. 6.5 Using the Temperature Transmitter with a RTD (3-wire) The Temperature Transmitter can be used in combination with a 3-wire RTD. To do so, the default configuration of the device needs to be changed. See "Communication Protocol" in Related documents. 6.5.1 Connecting a RTD (3-wire) sensor to the temperature interface
(a) Open the locking lever and insert wire
(b) Connector with levers closed Figure 14: Cable connection example Pin Pin 1 Pin 2 Pin 3 Pin 4 Connection RTD Sense (red) RTD + (red) RTD - (white) Do not use Table 10: RTD pinout 1. Strip the wires down by 7mm;
2. Insert the cable through the waterproofing O-Ring and cable gland nut;
3. Open the locking lever of the push in connector;
4. Press the RTD wire in the connector, use table. 10 to verify polarity. Do not use excessive force;
Ensure the correct polarity, as the device will not function properly with reversed polarity;
5. Close the locking lever of the push in connector;
6. Tighten the nut with the O-Ring. NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 24 of 34 12123 7 PRODUCT FUNCTIONALITIES 7 Product Functionalities A detailled description of setting-up communication and configuring device settings can be found in "Communication protocol", refer to table 1. Related documents. 7.1 Application Event Message The temperature transmitter measures and reports the temperature either by set intervals (a timer-based trigger) or a condition-based trigger.
[C]
Trigger Trigger Above Increasing Decreasing Time Trigger Trigger Below Figure 15: Application trigger event message 7.1.1 Event-triggers Event-messages are triggered on one of the following triggers. Timer (periodic):
The timer trigger is configurable through the following configurations:
temperature_measurement_interval_seconds Interval in seconds, at which the temperature sensor is read. periodic_event_message_interval Interval in the number of measurements at which the application event messages are periodically sent. The periodic counter is reset on every event message. Condition:
A condition-based trigger can be either of the following triggers:
Above If the maximum temperature is above the temperature_threshold then the condition is true. A transition of the condition from false to true or true to false will trigger an event message. 25 of 34 NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 7 PRODUCT FUNCTIONALITIES Below If the minimum temperature is below the temperature_threshold then the condition is true. A transition of the condition from false to true or true to false will trigger an event message. Increasing The condition is true when the current temperature is at least temperature_threshold higher than the minimum temperature in the measurement_window (The maximum number of measurements to observe delta temperature to trigger an event). A transition of the condition from false to true or true to false will trigger an event message. Decreasing The condition is true when the current temperature is at least temperature_threshold lower than the maximum temperature in the measurement_window (The maximum number of measurements to observe delta temperature to trigger an event). A transition of the condition from false to true or true to false will trigger an event message. 7.1.2 Content application event message Temperature The connected sensor temperature in units of 0.1 C:
Maximal;
Average;
Minimal. Trigger Source of the trigger for the application event message:
"timer" (0);
"condition_0" (1);
"condition_1" (2);
"condition_2" (3);
"condition_3" (4). condition_n The current state of each condition. 7.2 Device Status Besides reporting the application temperature as discussed previously, the Temperature Transmitter also reports on the device status itself. This is done through a device status messages. A device status message is sent periodically and includes a range of device health parameters, including the following:
event_counter;
battery_voltage;
PCB temperature;
tx_counter;
avg_rssi;
avg_snr. See "Communication Protocol" in Related documents for a detailed explanation. 7.3 Default Configuration The Temperature Transmitter is delivered with a default configuration. The default configuration includes:
Measurement interval of 15 mins;
Event-based message at the time of each periodic trigger with an interval of 15 measurements. (15 * 15 = 225 mins);
Device status message interval of 24 hours;
Enabled confirmation message on all messages. See "Communication Protocol" in Related documents for a detailed explanation of all default configuration values. NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 26 of 34 8 MAINTENANCE 8 Maintenance 8.1 Battery Specifications Specifications Manufacturer Part number Quantity Battery Type / Size Chemistry Terminal Type Dimensions Battery Life Tadiran Tadiran S1P1/SL-2780/323/TWT 1 Type D Lithium Thionyl Chloride Standard 61 x 32.5 mm
>7 years*
Table 11: Battery Specifications
*Note: Applicable to default configuration. Battery lifetime depends on average ambient temperature, network quality and device configuration. 8.1.1 Battery Replacement The battery can be replaced using the battery replacement kit. See Accessories and Spare Parts. This kit consists of the following parts:
1X Tadiran S1P1/SL-2780/323/TWT ;
4X O-Ring;
1X Gasket 8.1.2 Required tools Torque screwdriver with TX10 bit;
See Assembly of device for torque settings;
ESD strap. IMPORTANT: ESD Sensitive Electronics The product shall be installed in such a way that the risk for electrostatic discharges is minimised. Take proper precaution such as a grounded wrist strap and avoid touching the electronics board 27 of 34 NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 8 MAINTENANCE 8.1.3 Disassembly of device WARNING - DO NOT OPEN WHEN AN EXPLOSIVE ATHMOSPHERE IS PRESENT This equipment shall only be opened by TWTG or by a competent instructed person;
The battery is serviceable by said persons;
Always disconnect M12 connector from Transmitter before replacing battery assembly Step 1: Remove the four M3 screws and remove the bottom Step 2: Before removing the battery assembly, disconnect the housing battery connector (marked in red) Step 3: Place the new battery assembly. Use the rib on the battery cradle (marked in red) to align with designated cut out in top housing and connect the new battery connector NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 28 of 34 Align 8.1.4 Built-In Self-Test Procedure When the device is deactivated a built-in self-test is performed upon insertion of the battery. This test is not executed when the device is already activated. Use the deactivation sequence as described in Device Deactivation and reinsert the batteries if a self-test is needed. 8 MAINTENANCE Figure 16: Built-in self-test 1: After successful replacement of the battery the device will go into self test mode. This mode is activated for 30 seconds;
1.1: A BLUE LED will show after inserting the battery;
1.2: If no LED is shown, check the battery and / or device;
2: Start the test;
2.1: Press and Release the button;
3: Test Results;
3.1: LED turns bright WHITE for 5 seconds. Self test passed;
3.2: LED turns RED, self test failed. Check device;
3.3: No LED, no response from device. Check device. After pressing the button once and passing the self-test the device will leave the self-test mode. Pressing the button again will show the device status, as explained in Read device status. 29 of 34 NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 8 MAINTENANCE 8.1.5 Assembly of device IMPORTANT - USE THE SPECIFIED TORQUE SETTINGS Use a torque screwdriver to verify the applied torque;
Failure to do so can result in water ingress;
Improper assembly will void the warranty. Step 4: Replace the 4 O-Rings surrounding the screws and the gasket in the outer edge of the bottom housing Step 5: Place the bottom housing back onto the top housing. For correct orientation; Make sure that the bottom housing grounding plate is aligned with the top housing M12 connector Step 6: Tighten the four M3 screws to fix the bottom housing. Use a torque screwdriver to set the maximum torque to 1 Nm NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 30 of 34 Align 9 ACCESSORIES AND SPARE PARTS 9 Accessories and Spare Parts Type Order code Description Battery Replacement Kit 5029_N02-09_Battery-
Replacement-Kit Including 1 battery assembly, 4 O-Rings, 1 gasket M12 compatible connector compatible M12 connector angled Phoenix 1424655 Phoenix 1424656 Contact Push-in, metal, straight connector Contact Push-in, metal, right angle connector Table 12: Available Accessoires & Spare Parts 31 of 34 NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 10 EU DECLARATION OF CONFORMITY 10 EU Declaration of Conformity This product complies with the following standards:
1. ATEX Directive (2014/34/EU):
EN 60079-0:2012 +A11:2013 EN 60079-0:2018 EN 60079-11:2012 2. Radio Equipment Directive (2014/53/EU):
EN 300 220-1 V3.1.1 EN 300 220-2 V3.2.1 EN 301 489-1 V2.2.3 EN 301 489-3 V2.1.1 EN 61010-1:2010 + A1:2019 + A1:2019/AC:2019 EN 62311:2020 EN 60529:1991 + A1:2000 + A2:2013 3. WEEE Directive 2003/1008/EC 4. RoHS (2011/65/EU) For the full Declaration of Conformity see:
www.twtg.io/legal NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 32 of 34 11 FCC AND ISED DECLARATIONS 11 FCC and ISED Declarations This device complies with part 15 of the FCC Rules and to RSS of Industry Canada. Operation is subject to the following two conditions:
1. this device may not cause harmful interference, and 2. this device must accept any interference received, including interference that may cause undesired operation. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
1. lappareil ne doit pas produire de brouillage, et 2. lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numrique de Classe B est conforme la norme Canadienne ICES-003. CAN ICES-003(B) / NMB-003(B) 33 of 34 NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 Revision History Revision Date A1 A2 29-07-2022 05-10-2022 WK Author(s) SvW A3 24-11-2022 WK Description
- Concept version
- Updated product specifications and ratings
- Added French warnings
- Updated FCC/ISED declaration NEON-Temperature-Transmitter_User-Manual_DS-TT-02-xx_4001_A3 34 of 34
1 2 | Users Manual Vibration Sensor | Users Manual | 3.91 MiB | December 16 2022 / March 01 2023 | delayed release |
Vibration Sensor Product Manual This document applies to version 2 of the NEON Vibration Sensor (DS-LD-02-XX) NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 Version A4 23-11-2022 Contents 1 TWTG NEON 1.1 NEON Product Introduction . 1.2 Related Documents . 4 4 4 2 Getting Started 5 5 2.1 Compatibility of this manual
. 5 2.2 What you will need . 5 2.3 What is in the box . 6 2.4 Product Specifications . 8 2.5 Product Type Identification . 2.6 Component Names 9
. 2.7 Product Dimensions . 10
. 10
. 10 2.7.1 Transmitter 2.7.2 Sensor 3 Warnings 11 3.1 ATEX / IECEx . 11 3.1.1 Specific Conditions of Use . 11 3.1.2 Installation . 11 3.1.3 Operation . 11 3.1.4 Service . 11 3.2 General . 12 3.2.1 Transport and Storage . 12 3.2.2 Warranty . 12
. 12 3.2.3 Warranty will be void in case of 4 Avertissements 13 4.1 ATEX / IECEx . 13 4.1.1 Conditions spcifiques dutilisation . 13 4.1.2 Installation . 13 4.1.3 Fonctionnement
. 13 4.1.4 Entretien . 13 4.2 Informations gnrales . 14 4.2.1 Transport et stockage . 14 4.2.2 Garantie . 14
. 14 4.2.3 La garantie sera annule dans les cas suivants:
5 Provisioning 15 5.1 User Interface . 15 5.2 Operating the Device . 15 5.2.1 Read device status . 16 5.2.2 Device Activation . 17 5.2.3 Device Deactivation . 18 5.3 Product Identification . 19 5.3.1 NFC . 19 5.3.2 Data Matrix Code . 19 NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 2 of 39 CONTENTS 6 Installation of the Transmitter 20
. 20 6.1 Precautions 6.2 Mounting Bracket Dimensions . 20 6.3 Installation Methods . 21 6.3.1 Installation using mounting holes . 21 6.3.2 Installation using threaded holes . 21 6.3.3 Installation using bandclamp . 22 7 Installation of the Vibration Sensor 7.4 Using Chemically Bonded Adapter 23
. 23 7.1 General Installation Requirements 7.2 Vibration Sensor Orientation . 23 7.3 Direct installation using the mounting hole . 24 7.3.1 Dimensions . 24
. 25 7.4.1 Dimensions . 25 7.5 Using Magnet Adapter (Flat) . 26 7.5.1 Dimensions . 26 7.6 Using Magnet Adapter (Curved) . 27 7.6.1 Dimensions . 27 7.7 Connecting the Vibration Sensor to the Transmitter . 28 8 Product Functionalities 29 8.1 Application Event Message . 29 8.1.1 Event triggers
. 29 8.1.2 Content application event message . 29 8.2 Sensor Data Message . 30
. 30 8.3 Device Status 8.4 Default Configuration . 31 9 Maintenance 32 9.1 Battery Specifications . 32
. 32 9.2 Battery Replacement 9.2.1 Required tools . 32 9.2.2 Disassembly of device . 33 9.2.3 Built-In Self-Test Procedure . 34 9.2.4 Assembly of device . 35 10 Accessories and Spare Parts 11 EU Declaration of Conformity 12 FCC and ISED Declarations 36 37 38 3 of 39 NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 1 TWTG NEON 1 TWTG NEON 1.1 NEON Product Introduction NEON stands for a standardised approach to collecting data points from the operational environment and in doing so, creates a general approach to integrated solutions within existing IT ecosystems. The TWTG NEON product range supports all industrial customers moving towards LoRaWAN as the Industrial IoT network of the future. The LoRaWAN network gives industrial operations a secure solution, which scales-up to tens of thousands of sensors, covers complete sites with only a small amount of gateways and best of all the low-power approach means that the lifetime of the NEON products can be extended dramatically. 1.2 Related Documents Document Name NEON Data Sheet Document Number 6016_N02-09_Data-Sheet-NEON-Vibration-Sensor NEON Communication Protocol 6013_N02-09_Communication-Protocol-NEON-Vibration-Sensor 3M Scotch Weld Epoxy Datasheet DP8405NS Green Table 1: Related Documents NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 4 of 39 2 GETTING STARTED 2 Getting Started 2.1 Compatibility of this manual This manual is meant to be used with products of from a specific production batch. See Product Type Identification for an explanation on how to retrieve the production batch code from the serial number. This manual is applicable to version 2 of the NEON Vibration Sensor. See chapter Product Type Identification to determine the revision of the product. 2.2 What you will need In order to deploy the NEON Transmitter, a compatible and operational LoRaWAN network architecture is required. This manual does not contain any instructions of how-to set-up and install LoRaWAN networks. TWTG offers radio network planning and IT architecture design services to fully integrate the products in the NEON product line. 2.3 What is in the box When the product is delivered check the components for damage and if all box items mentioned below are included. Box Items NEON Transmitter NEON Vibration Sensor Declaration of Conformity 1 battery assembly, included in the product 1 mounting bracket, mounted on the product M12 connector and O-ring, mounted on the product M6 Bolt Declaration of Conformity, containing a link to the latest version of this product manual and other relevant product documentation Table 2: Box Items 5 of 39 NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 2 GETTING STARTED 2.4 Product Specifications Product Product name Type identification Transmitter Type identification Sensor Environmental conditions Operating temperature range Transmitter Storage temperature range Operating humidity range Altitude Water & dust resistance Pollution degree Usage Mechanical (Transmitter) Material TWTG NEON Vibration Sensor DS-LD-02-XX DS-VB-02-XX
-40C - 70C 10C - 30C 0% - 100% RH Up to 3000 m IP65 3 Indoor and outdoor Molded plastic Weight (including mounting bracket) 260 g Dimensions Mechanical (Sensor) Material Weight Dimensions Installation Transmitter Sensor Power Supply specifications Battery rated voltage Battery rated capacity Functional specifications Output Input 100x70x57 mm Stainless steel and polyurethane 560 g 40x21 mm
Band clamp or bolts (not included) Bolt Chemically bonded adapter (not included) Magnet for curved surfaces (not included) Magnet for flat surfaces (not included) 3.6 V 17 Ah LoRaWAN M12 connector for thermocouple or RTD input Input insulation rating 500VAC / 1 min Connectivity Protocol Frequency band LoRaWAN 863-870 MHz 902-928 MHz (compatible) Maximum RF output power
+13 dBm Provisioning QR / Serial number NFC Serial number (read only) Serial number (read only) Table 3: Product specifications. See also "NEON datasheet" in Related Documents for a detailed overview of specifications. NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 6 of 39 2 GETTING STARTED Certifications ATEX certificate number IECEx certificate number ATEX IECex marking Applicable ATEX/IECEx standards FM US certificate number FM CA certificate number US Marking CA Marking IMDA Dealer License CE UKCA FCC ISED ICES Manufacturer information Name Address DEKRA 20ATEX0004X IECEx DEK 20.0004X Ex II 1G Ex ia IIC T4 Ga EN 60079-0 EN 60079-11 FM22US0061X FM22CA0043X IS Class I, Division 1, Group ABCD T4 Class I, Zone 0 Ex ia IIC T4 Ga IS Class I, Division 1, Group ABCD T4 Ex II 1G AEx ia IIC T4 Ga DA108442 EN 300 220-1 EN 300 220-2 EN 61010-1:2010 + A1:2019 + A1:2019/AC:2019 EN 62311 EN 60529 EN 301 489-1 EN 301 489-3 Radio Regulation 2017 FCC CFR 47, Part 15, Subpart C FCC CFR 47, Part 15, Subpart B USA FCC Part 15.209, 15.247, 15.205 RSS-247, RSS-Gen CAN ICES-003(B) / NMB-003(B) TWTG R&D BV Schaardijk 386 2909 LA Capelle a/d IJssel The Netherlands Table 4: Product specifications. See also "NEON datasheet" in Related Documents for a detailed overview of specifications. 7 of 39 NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 2 GETTING STARTED 2.5 Product Type Identification AA-BB-CC-DD AA - Product Family DS BB - Product Variant LD = Transmitter CC - Main Revision 02 DD - Region E.g. 00 = Global Product Nomenclature AA-BB-CC-DD-EEEEE AA - Product Variant LD = Transmitter BB - Product Revision E.g. 02 CC - Product Region E.g. 00 = Global DD - Production Year E.g. 22 = 2022 EE - Production Batch E.g. AA FFFFF - Serial Number E.g. 00001 Serial Number Figure 1: Transmitter product identification AA-BB-CC-DD AA - Product Family DS BB - Product Variant VB = Vibration Sensor CC - Main Revision 02 DD - Region E.g. 00 = Global Product Nomenclature AA-BB-CC-DD-EEEEE AA - Product Variant VB = Vibration Sensor BB - Product Revision 02 CC - Region E.g. 00 = Global DD - Production Year E.g. 22 = 2022 EE - Production Batch E.g. AA FFFFF - Serial Number E.g. 00001 Serial Number Figure 2: Vibration Sensor product identification NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 8 of 39 DS-LD-02-00LD020022AA00001DS-VB-02-01VB0222AA00001II 1G Ex ia IIC T4 Ga-40 C Ta 80 CDEKRA 22ATEX0004XIECEx DEK 22.0004XFM ID US: FMXXXXXXXXXFM ID CA: FMXXXXXXXXXIS Class I, Division 1, Group ABCD T4Class I, zone 1 AEx/Ex ia IIC T4 Ga -40 C Ta 80 CFCC ID: 2ATYF-DSXX02XXIC: 28385-DSXX02XXModel: DSXX02XX 2.6 Component Names 2 GETTING STARTED Number 1 2 3 4 5 7 8 9 10 Figure 3: Component Names Description Neon Transmitter Data Matrix Code NFC Tag Mounting Bracket M12 Connector Dust Cap Vibration Sensor Sensor Label Sensor (M12) Connector M6 Bolt Table 5: Component Names 9 of 39 NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 9873125410 2 GETTING STARTED 2.7 Product Dimensions 2.7.1 Transmitter Figure 4: Neon Transmitter Dimensions (mm) 2.7.2 Sensor Figure 5: Neon Vibration Sensor Dimensions (mm) NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 10 of 39 109 48 84 64 -4,5 CAP 57 40 25,5 36 6,3 2950 50 21 23 13,3 3 WARNINGS 3 Warnings 3.1 ATEX / IECEx 3.1.1 Specific Conditions of Use WARNING - POTENTIAL ELECTROSTATIC CHARGING HAZARD The product shall be installed in such a way that the risk for electrostatic discharges is minimised;
When the equipment is used in hazardous locations, avoid any actions which generate electrostatic discharge;
Cleaning: The equipment shall only be cleaned using a wet cloth;
Installation: Touch non-metallic parts with an insulating object;
Environment: Do not use the product in environments with powerful charge generating processes. 3.1.2 Installation This equipment shall be installed according to NEN-EN-IEC 60079-14 and the installation instructions;
This equipment is intended for fixed installations only;
This equipment is intended for use in restricted access areas only;
To comply with FCC/IC RF exposure limits for general population / uncontrolled exposure, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. WARNING - DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT Under no circumstances shall the equipment enclosure be opened within a hazardous area 3.1.3 Operation The connector of this equipment may only be used with external equipment as listed in the Product Matrix;
The connector of this equipment shall not be connected when an explosive atmosphere is present;
This equipment shall only be used in environments where electromagnetic field strength is limited according to EN 60079-14;
This equipment is only intended for use in combination with NFC Forum Tag 2 Type technical specification compatible readers;
This equipment shall only be used within ambient temperatures between -40 C and 70 C. The DS-VB-02-XX may be used within ambient temperatures between -40 C and 80 C. 3.1.4 Service This equipment shall only be opened by TWTG or by a competent instructed person;
The battery is serviceable by said persons;
Only replace the battery in a non-hazardous location;
Only use Tadiran S1P1/SL-2780/323/TWT battery assembly;
Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. If damage to the enclosure is evident, a trained and competent person shall be immediately informed, who shall remove the device from service as soon as possible;
If the equipment is or has been in contact with chemical materials, clean it appropriately. 11 of 39 NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 3 WARNINGS 3.2 General 3.2.1 Transport and Storage The product must be kept in its original packaging until it reaches the installation site to prevent damage while in transit;
The storage location must be dry;
The product must not be exposed to vibrations or impact during transit and storage. 3.2.2 Warranty The warranty covers the period noted on the quotation;
If the device doesnt function as documented, the customer should contact TWTG and provide the following information:
Model specification;
Serial number;
Circumstances under which the problems developed;
Any previously generated data;
The party responsible for the costs of solving the problem shall be determined by TWTG on the basis of an investigation conducted by TWTG. 3.2.3 Warranty will be void in case of Malfunction due to ignoring the design specifications;
Malfunction due to modification of the product carried out by the user;
Deferred maintenance of the product or the installation location. NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 12 of 39 4 AVERTISSEMENTS 4 Avertissements 4.1 ATEX / IECEx 4.1.1 Conditions spcifiques dutilisation ATTENTION RISQUE POTENTIEL DE DECHARGES ELECTROSTATIQUES Le produit doit obligatoirement tre install de manire minimiser le risque de dcharges lectrostatiques;
Lorsque lquipement est utilis dans un environnement dangereux, vitez strictement toute action gnrant une dcharge lectrostatique;
Nettoyage: Lquipement doit tre nettoy uniquement laide dun chiffon humide;
Installation: Toucher les parties non mtalliques quavec un objet isolant;
Environnement: Nutilisez pas le produit dans des environnements gnrant de fortes charges dlectricit. 4.1.2 Installation Cet quipement doit tre install conformment la norme NEN-EN-IEC 60079-14 et aux instructions dinstallation;
Cet quipement est uniquement destin aux installations fixes;
Cet quipement est uniquement destin tre utilis dans des zones accs restreint. ATTENTION NE PAS OUVRIR DANS UNE ATMOSPHRE EXPLOSIVE Le botier de lquipement ne doit en aucun cas tre ouvert dans une zone dangereuse. 4.1.3 Fonctionnement Le connecteur de cet quipement ne doit tre utilis quavec un quipement externe tel quindiqu dans le "product matrix";
Le connecteur de cet quipement ne doit jamais tre connect dans une atmosphre explosive;
Cet quipement ne doit tre utilis que dans un environnement o lintensit du champ magntique est limite conformment la norme EN 60079-14;
Cet quipement est uniquement destin tre utilis en combinaison avec des lecteurs compatibles dont les spcifications techniques respectent la norme des tags NFC de Type 2;
Cet quipement ne doit tre utilis qu des tempratures comprises entre 40 C et 70 C;
Le DS-VB-02-XX ne doit que tre utilis qu des tempratures comprises entre -40 C et 80 C. 4.1.4 Entretien Cette pice dquipement ne doit tre ouverte que par TWTG ou par une personne comptente et selon le guide dutilisation;
La batterie peut tre mise neuf par ces personnes;
Ne remplacez la batterie que dans un endroit sans danger;
Utilisez uniquement lensemble de batterie Tadiran S1P1/SL-2780/323/TWT ;
Si le botier est endommag, informez immdiatement une personne comptente pour quelle vienne rcuprer lquipement;
Si lquipement est (ou a t) en contact avec des substances chimiques, nettoyez-le de manire approprie. 13 of 39 NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 4 AVERTISSEMENTS 4.2 Informations gnrales 4.2.1 Transport et stockage Le produit doit tre conserv dans son emballage jusqu ce quil atteigne le site dinstallation pour viter tout dommage pendant le transit;
Le lieu de stockage doit tre sec;
Lappareil ne doit pas tre expos des vibrations ou des chocs pendant le transport et le stockage. 4.2.2 Garantie La garantie couvre la priode indique sur le devis;
Si lappareil ne fonctionne pas comme prvu, le client doit contactez TWTG et fournir les lments suivants;
Spcifications du modle;
Numro de srie;
Les circonstances dans lesquelles les problmes sont survenus;
Toutes les donnes prcdemment gnres;
La partie responsable des cots de rsolution du problme sera dtermine par TWTG sur la base dune enqute prive mene par TWTG. 4.2.3 La garantie sera annule dans les cas suivants:
Non-respect des spcifications du modle;
Modification du produit effectue par lutilisateur;
Entretient non conforme aux spcifications du produit;
Utilisation dans un endroit non conforme aux spcifications. NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 14 of 39 5 PROVISIONING 5 Provisioning 5.1 User Interface The product contains one Light Emitting Diode (LED) to communicate with the user. In order to interact with the device a button is present on the right side of the NFC label. Figure 6: NEON Transmitter Interface 5.2 Operating the Device Press and Release Press and Hold Release Red (Illuminated 2 s) Deactivated Red (Illuminated) Failed Green (Illuminated 2 s) Activated Green (Illuminated) Passed White (Blinking) Connecting White (Illuminated) Calibrating Blue (Illuminated) Action / Handling Required Blue (Flashing each second) Button is being hold 15 of 39 NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 LEDButton 5 PROVISIONING 5.2.1 Read device status 1. Press & release the button and the device will immediately show its status:
2.1 Green (Illuminated): Device is activated 2.2 Red (Illuminated): Device is deactivated If the device is activated it will try to send the Device Status message over LoRa (using default configuration):
3. White (Blinking): Connecting to network Within a typical maximum of 3 minutes*, device will show:
the 4.1 Green (Blink 2x): Message sent, or 4.2 Red (Blink 2x): Failed to connect to send message / connect to network Notes:
The NEON Transmitter can be configured to send a Sensor Data message upon a button press. In this configuration the Sensor Data message will be sent after the Sensor Event message;
*All timeout and retry values are valid for the default configuration, the maximum timeout might be longer when process is performed repeatedly due to RF duty cycle limitations. NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 16 of 39 5 PROVISIONING 5.2.2 Device Activation 1. Press & hold the button for 5 seconds During the button hold the LED will blink Blue each second. 2. After holding the button for 5 seconds the device will first check the LoRa network:
3.1 White (Blinking): Checking LoRa network 4. Within a typical maximum of 3 minutes* the device will show:
4.1 White (Illuminated): Checking sensor communication 4.2 Red (Blink 2x): Check network 5. Within 30 seconds max. the device will show:
5.1 White (Blinking): Sending activation over LoRa 5.2 Red (Blink 2x): Check sensor 6. After communicating over LoRa, within a typical maximum of 3 minutes*, the device will show:
6.1 Green (Illuminated): Activated, or 6.2 Red (Blink 2x): Check network Notes:
*All time out and retry values are valid for the default configuration, the maximum time out might be longer when process is performed repeatedly due to RF duty cycle limitations. 17 of 39 NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 5 PROVISIONING 5.2.3 Device Deactivation 1. Normal Configuration During the button hold the LED will blink Blue each second. 2. After holding the button for 5 seconds the device will show:
2.1 Blue (Illuminated): Action required 3. The user can now release the button and press and release within 5 seconds:
If the button isnt pressed & released within 4. these 5 seconds:
Red (Illuminated): Deactivated No LED: Deactivation canceled Notes:
Secured Configuration If the device is in Secured Configuration it is not possible to deactivate the device using the button. The device will not react to a press and hold of the button and the LED will stay off. See diagram 1.2, 2.2 and 3.2 and "Communication Protocol" in Related Documents. NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 18 of 39 5 PROVISIONING 5.3 Product Identification 5.3.1 NFC The NFC label is located in the identification sticker and programmed with the serial number of the device. The serial number read from the NFC can be used as unique identifyer for provisioning and registration. 5.3.2 Data Matrix Code The Data Matrix Code label also represents the serial number of the device. The serial number read from the Data Matrix Code code can be used as unique identifyer for provisioning and registration. See Product Type Identification for a detailed label description. Figure 7: NFC and Data Matrix Code code Location 19 of 39 NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 DS-LD-02-00LD020022AA00001 6 INSTALLATION OF THE TRANSMITTER 6 Installation of the Transmitter 6.1 Precautions WARNING Avoid placing wiring close to noise sources such as large motors or power supplies;
To comply with FCC/IC RF exposure limits for general population / uncontrolled exposure, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter;
Only connect the M12 connector to the Transmitter when there is no explosive atmosphere present;
The equipment must be installed in accordance with EN 60079-14. 6.2 Mounting Bracket Dimensions Figure 8: Mounting Bracket Dimensions (in mm) NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 20 of 39 8 22 25,5 4,4 74 6 INSTALLATION OF THE TRANSMITTER 6.3 Installation Methods 6.3.1 Installation using mounting holes Place the bracket against the (flat) desired surface and use the screw holes or slots to fix in place. Note: Slots and screw holes are designed for M4 fasteners. Figure 9: Product Mounting Holes 6.3.2 Installation using threaded holes Note: Threaded screw holes are designed for M5 fasteners. Figure 10: Product Threaded Mounting Holes 21 of 39 NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 6 INSTALLATION OF THE TRANSMITTER 6.3.3 Installation using bandclamp The Neon Transmitter can be mounted to a pole using a 14 mm wide band clamp, other sizes are not recommended. Procedure:
1. Place the band clamp through the bracket;
2. Place the band clamp around the pole and cut to size;
3. Place the band clamp through the adjustable tightener and fold around the bottom with a plier;
4. Place the band clamp around the pole with the (adjustable) tightener and fix it in place. Figure 11: Installation using Bandclamp NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 22 of 39 7 INSTALLATION OF THE VIBRATION SENSOR 7 Installation of the Vibration Sensor 7.1 General Installation Requirements IMPORTANT Always use a torque wrench set to the listed torque to tighten the mounting screw;
The mounting surface should be flat and always be cleaned before mounting the sensor;
Failure to do so may affect measurements;
Install according to EN 60079-14. 7.2 Vibration Sensor Orientation For correct operation the Vibration Sensor needs to be mounted in the correct orientation. Use the cable as a reference for the Y-axis direction. Figure 12: Mounting Orientation 23 of 39 NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 XYYXZ 7 INSTALLATION OF THE VIBRATION SENSOR 7.3 Direct installation using the mounting hole Procedure:
1. Find a flat surface of at least 40 mm in diameter;
2. The surface should be flat, undamaged and clean;
3. Create a threaded hole, size M6 with a thread depth of at least 8 mm;
4. Attach the Vibration Sensor using the supplied M6 bolt, according to Direct Mounting Assembly;
5. Ensure proper orientation according to Vibration Sensor Orientation;
6. Tighten the screw using a torque wrench:
Minimum torque: 14 Nm;
Maximum torque: 16,3 Nm. 7.3.1 Dimensions Figure 13: Direct Mounting Assembly Figure 14: Direct Mounting Dimensions (mm) NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 24 of 39 Min. 14 NmMax. 16,3 Nm 34,4 7,4 M6x30 40 23 6,3 THRU 7 INSTALLATION OF THE VIBRATION SENSOR 7.4 Using Chemically Bonded Adapter Procedure:
1. Find a flat and surface of at least 40 mm in diameter;
2. See "3M Scotch Weld Epoxy Datasheet" in Related Documents on how to prepare the surface;
3. Use "3M DP8405 Green" Acrylic Adhesive and compatible dispenser products. Attach adapter to the surface according to "3M Scotch Weld Epoxy Datasheet" in Related Documents. Make to the mounted sure the adapter is parallel surface;
4. Let the adhesive cure for the time as stated in the "3M Scotch Weld Epoxy Datasheet";
5. Attach the Vibration Sensor to the adapter using the supplied M6 bolt, according to Chemically Bonded Adapter Assembly;
6. Ensure proper orientation according to Vibration Sensor Orientation;
7. Tighten the screw using a torque wrench:
Minimum torque: 14 Nm;
Maximum torque: 16,3 Nm. 7.4.1 Dimensions Figure 15: Chemically Bonded Adapter Assembly Figure 16: Chemically Bonded Adapter Dimensions (mm) 25 of 39 NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 Min. 14 NmMax. 16,3 Nm 11 38 19 A/F M6x30 40 23 7 INSTALLATION OF THE VIBRATION SENSOR 7.5 Using Magnet Adapter (Flat) Procedure:
1. Hold the Magnet Adapter in position, using the proper tool;
2. Attach the Vibration Sensor using the supplied M6 bolt, according to Curved Magnet Adapter Assembly;
3. Tighten the screw using a torque wrench:
Minimum torque: 14 Nm;
Maximum torque: 16,3 Nm;
4. Find a flat and surface of at least 40 mm in diameter;
5. The surface should be flat, undamaged, and clean;
6. Attach the Vibration Sensor using the magnet;
7. Ensure proper orientation according to Vibration Sensor Orientation. 7.5.1 Dimensions Figure 17: Flat Magnet Adapter Assembly Figure 18: Flat Magnet Adapter Dimensions (mm) NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 26 of 39 Min. 14 NmMax. 16,3 Nm 15,7 41,9 1/4-28x1,12" 40 38 7 INSTALLATION OF THE VIBRATION SENSOR 7.6 Using Magnet Adapter (Curved) Procedure:
1. Hold the Magnet Adapter in position;
2. Attach the Vibration Sensor using the supplied M6 bolt, according to Curved Magnet Adapter Assembly;
3. Tighten the screw using a torque wrench:
Minimum torque: 14 Nm;
Maximum torque: 16,3 Nm;
4. The surface should be undamaged and clean;
5. Attach the Vibration Sensor using the magnet;
6. Ensure proper orientation according to Vibration Sensor Orientation. 7.6.1 Dimensions Figure 19: Curved Magnet Adapter Assembly Figure 20: Curved Magnet Adapter Dimensions (mm) 27 of 39 NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 Min. 14 NmMax. 16,3 Nm 31,8 56,4 23 1/4-28x1,12" 25 40 38 7 INSTALLATION OF THE VIBRATION SENSOR 7.7 Connecting the Vibration Sensor to the Transmitter 1. Unscrew the dust cap from the product. Check inside the M12 connector for correct placement of the O-Ring
(marked in red). Without this O-Ring, the water and dust resistance rating of the product cannot be guaranteed. Figure 21: M12 Connector O-ring Location 2. Connect the Sensor connector to the Transmitter. Ensure correct polarity before inserting the connector. The polarity notch is facing up. Completely tighten the connector but do not use excessive force. If the connector is not fully inserted, water and dust resistance rating cannot be guaranteed. Figure 22: M12 Connector Polarity Mark NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 28 of 39 8 PRODUCT FUNCTIONALITIES 8 Product Functionalities A detailled description of setting-up communication and configuring device settings can be found in "Communication protocol", refer to table 1. Related Documents. 8.1 Application Event Message The Vibration Sensor measures and reports the vibrations either by set intervals (a timer-based trigger) or a condition-
based trigger. 8.1.1 Event triggers Event-messages are triggered on one of the following triggers:
Timer (periodic):
The timer trigger is configurable through the following configurations:
measurement_interval_seconds Interval in seconds, at which the vibration sensor is read. periodic_event_message_interval Interval in the number of measurements at which the application event messages are periodically sent. The periodic counter is reset on every event message. Condition:
A condition-based trigger can be either of the following tresholds:
rms velocity trigger_x peak acceleration trigger_x rms velocity trigger_y peak acceleration trigger_y rms velocity trigger_z peak acceleration trigger_z 8.1.2 Content application event message Rms velocity The measured rms velocity for each of the axis (X,Y,Z) in units of 0.01 mm/s. Maximum;
Average;
Minimum. Acceleration The measured acceleration for each of the axis (X,Y,Z) in units of 0.01 m/s 2. Maximum;
Average;
Minimum. Temperature The connected sensor temperature in units of 0.1 C:
Maximum;
Average;
Minimum. Trigger Source of the trigger for the application event message:
"timer" (0);
"condition_0" (1);
"condition_1" (2);
"condition_2" (3);
29 of 39 NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 8 PRODUCT FUNCTIONALITIES
"condition_3" (4). Condition_n The current state of each condition. 8.2 Sensor Data Message The FFT (sensor data message) is split between a configurable amount of messages. For a detailed explanation of available configurations see "Communication Protocol" in Related Documents. The sensor data message can be recombined to a full spectrum as shown in figure Example FFT. Figure 23: Example FFT 8.3 Device Status Next to reporting the application events, the Vibration Sensor also reports on the device status itself. This is done through a device status messages. A device status message is sent periodically and includes a range of device health parameters, including the following:
event_counter;
battery_voltage;
PCB temperature;
tx_counter;
avg_rssi;
avg_snr. See "Communication Protocol" in Related Documents for a detailed explanation. NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 30 of 39 050100150200250f (Hz)050100150200250|A(f)|Velocity spectrum (5-205 Hz)10203040f (Hz)050100150200250|A(f)|frame_num 150607080f (Hz)050100150200250|A(f)|frame_num 290100110120f (Hz)050100150200250|A(f)|frame_num 3130140150160f (Hz)050100150200250|A(f)|frame_num ... 170180190200f (Hz)050100150200250|A(f)|frame_num 5 8 PRODUCT FUNCTIONALITIES 8.4 Default Configuration The Transmitter is delivered with a default configuration. The default configuration includes:
Measurement interval of 15 mins;
Event-based message at the time of each periodic trigger with an interval of 16 measurements. (16 * 15 = 240 minutes);
Device status message interval of 24 hours;
Enabled event confirmation messages;
All triggers disabled;
Disabled data messages confirmation (FFT);
Disabled FFT. See "Communication Protocol" in Related Documents for a detailed explanation of all default configuration values. 31 of 39 NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 9 MAINTENANCE 9 Maintenance 9.1 Battery Specifications Specifications Manufacturer Part number Quantity Battery Type / Size Chemistry Terminal Type Dimensions Battery Life Tadiran Tadiran S1P1/SL-2780/323/TWT 1 Type D Lithium Thionyl Chloride Standard 61 x 32.5 mm
>7 years*
Table 6: Battery Specifications
*Note: Applicable to default configuration. Battery lifetime depends on average ambient temperature, network quality and device configuration. 9.2 Battery Replacement The battery can be replaced using the battery replacement kit. See Accessories and Spare Parts. This kit consists of the following parts:
1X Tadiran S1P1/SL-2780/323/TWT battery assembly;
4X O-Ring;
1X Gasket 9.2.1 Required tools Torque screwdriver with TX10 bit;
See Assembly of device for torque settings;
Loctite 243;
ESD strap. IMPORTANT: ESD Sensitive Electronics The product shall be installed in such a way that the risk for electrostatic discharges is minimised. Take proper precaution such as a grounded wrist strap and avoid touching the electronics board NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 32 of 39 9 MAINTENANCE 9.2.2 Disassembly of device WARNING - DO NOT OPEN WHEN AN EXPLOSIVE ATHMOSPHERE IS PRESENT This equipment shall only be opened by TWTG or by a competent instructed person;
The battery is serviceable by said persons;
Always disconnect M12 connector from Transmitter before replacing battery assembly Step 1: Remove the four M3 screws and remove the bottom Step 2: Before removing the battery assembly, disconnect the housing battery connector (marked in red) Step 3: Place the new battery assembly. Use the rib on the battery cradle (marked in red) to align with main PCB in top housing and connect the new battery connector 33 of 39 NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 Align 9 MAINTENANCE 9.2.3 Built-In Self-Test Procedure When the device is deactivated a built-in self-test is performed upon insertion of the battery. This test is not executed when the device is already activated. Use the deactivation sequence as described in Device Deactivation and reinsert the batteries if a self-test is needed. Figure 24: Built-in self-test 1: After successful replacement of the battery the device will go into self test mode. This mode is activated for 30 seconds;
1.1: A BLUE LED will show after inserting the battery;
1.2: If no LED is shown, check the battery and / or device;
2: Start the test;
2.1: Press and Release the button;
3: Test Results;
3.1: LED turns bright WHITE for 5 seconds. Self test passed;
3.2: LED turns RED, self test failed. Check device;
3.3: No LED, no response from device. Check device. After pressing the button once and passing the self-test the device will leave the self-test mode. Pressing the button again will show the device status, as explained in Read device status. NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 34 of 39 9 MAINTENANCE 9.2.4 Assembly of device IMPORTANT - USE THE SPECIFIED TORQUE SETTINGS Use a torque screwdriver to verify the applied torque;
Failure to do so can result in water ingress;
Improper assembly will void the warranty. Step 4: Replace the 4 O-Rings surrounding the screws and the gasket in the outer edge of the bottom housing Step 5: Place the bottom housing back onto the top housing. For correct orientation; Make sure that the bottom housing grounding plate is aligned with the top housing M12 connector Step 6: Apply Loctite 243 and tighten the four M3 screws to fix the bottom housing. Use a torque screwdriver to set the maximum torque to 1 Nm 35 of 39 NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 Align 10 ACCESSORIES AND SPARE PARTS 10 Accessories and Spare Parts Type Order code Description Battery Replacement Kit Chemically Bonded Adapter 5029_N02-09_Battery-
Replacement-Kit 2013_P20-002_VB-
Adapter-Bonded Including 1 battery assembly, 4 O-Rings, 1 gasket Chemically Bonded Adapter Magnetic Mounting Adapter
(Flat) 080A122 Flat surface magnet, 1.5" diameter, 50 lbf, 1/4-28 threaded hole w/mounting stud Including mounting bolt Magnetic Mounting Adapter
(Curved) 080A132 Curved surface magnet, 1.5" diameter, 55 lbf, 1/4-28 threaded hole w/mounting stud Including mounting bolt Table 7: Available Accessoires & Spare Parts NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 36 of 39 11 EU DECLARATION OF CONFORMITY 11 EU Declaration of Conformity This product complies with the following standards:
1. ATEX Directive (2014/34/EU):
EN 60079-0:2012 +A11:2013 EN 60079-0:2018 EN 60079-11:2012 2. Radio Equipment Directive (2014/53/EU):
EN 300 220-1 V3.1.1 EN 300 220-2 V3.2.1 EN 301 489-1 V2.2.3 EN 301 489-3 V2.1.1 EN 61010-1:2010 + A1:2019 + A1:2019/AC:2019 EN 62311:2020 EN 60529:1991 + A1:2000 + A2:2013 3. WEEE Directive 2003/1008/EC 4. RoHS (2011/65/EU) For the full Declaration of Conformity see:
www.twtg.io/legal 37 of 39 NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 12 FCC AND ISED DECLARATIONS 12 FCC and ISED Declarations This device complies with part 15 of the FCC Rules and to RSS of Industry Canada. Operation is subject to the following two conditions:
1. this device may not cause harmful interference, and 2. this device must accept any interference received, including interference that may cause undesired operation. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
1. lappareil ne doit pas produire de brouillage, et 2. lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numrique de Classe B est conforme la norme Canadienne ICES-003. CAN ICES-003(B) / NMB-003(B) NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4 38 of 39 Revision History Revision Date A1 A2 A3 30-06-2022 22-07-2022 05-10-2022 WK Author(s) SvW SvW A4 23-11-2022 WK Description Concept version Added review comments
- Updated product specifications and ratings
- Added French warnings Updated FCC/ISED declaration 39 of 39 NEON-Vibration-Sensor_User-Manual_DS-VB-02-xx_4001_A4
1 2 | Internal photos | Internal Photos | 514.95 KiB | December 16 2022 / March 01 2023 | delayed release |
1 2 | External Photos | External Photos | 545.58 KiB | December 16 2022 / March 01 2023 | delayed release |
1 2 | ID Label/Location Info | ID Label/Location Info | 164.24 KiB | December 16 2022 / December 20 2022 |
111G ExiallC T4 Ga DEKRA 22ATEX0004X FCC ID: 2ATYF-DS02 40C < Tas 70C IECEx DEK 22.0004x IC: 28385-DS02 bi XXX22UKEX0001X Model: DSO2 IS CI], DIV 1, Group ABCD T4, FM ID US: FMXXXXXXXXX P65 JA\
CII, zone 1 AEx/Ex ia IIC T4 Ga FM ID CA: FMXXXXXXXXX Cel ek TWTG R&D BV - Schaardijk 386, 2909 LA Capelle a/d IJssel, The Netherlands
@ Wise 74 Ge DEKRA 22ATEXO004X FOC ID: 2aTyF-DS02 40C Tax 70C IECEx DEK 22.0004x Ic: 28985-Ds02
=, H IS.C11, 01V1, Group ABCD T4 FM ID US: FMX00000000 Cll, zone t AEWExialICT4Ga FMID CA: FMQ00G000K ~CsIPS. D 22AA00011 TWTG RAD BV - Schaardijk 386, 2909 LA Capelle a/d |Jssel, The Netheriands
1 2 | Declaration of Conformity Concept | Cover Letter(s) | 49.99 KiB | December 16 2022 / December 20 2022 |
Federal Communications Commission DECLARATION OF CONFORMITY June 28, 2022 Hereby We, Name of manufacturer:
Address:
Zip code & City:
Country:
Phone Number:
TWTG R&D BV Schaardijk 386 2909 LA, Capelle a/d IJssel The Netherlands
+31 (0)10 203 79 05 declare that this DoC is issued under our sole responsibility and that the following products:
Product description:
1. DS-TT-02-02 - Temperature Transmitter, intended to monitor the temperature in industrial environments and send it over LoRaWAN wireless protocol 2. DS-LD-02-02 - Low Voltage Differential Transmitter, intended to communicate with external sensors, and send their data over LoRaWAN wireless protocol 3. DS-PT-02-02 - Pressure Transmitter, intended to communicate with external pressure sensors, and send their data over LoRaWAN wireless protocol 4. DS-VB-02-02 - Vibration Sensor, intended to be connected to DS-LD-02-02 to monitor vibration of indus-
trial equipment and send it over LoRaWAN wireless protocol Type Designation(s):
1. DS-TT-CC-DD 2. DS-LD-CC-DD 3. DS-PT-CC-DD 4. DS-VB-CC-DD Trademark: TWTG R&D BV Designation DS-TT-02-02 DS-LD-02-02 DS-VB-02-02 Frequency 915 915 915 Revision Number (CC) 02 02 02 Regional Variant (DD) 02 02 02 This product is covered by the following FM classification:
PENDING: IS Class I, Division 1, Group ABCD T4 PENDING: Class I, Zone 1 AEX/Ex ia IIC T4 Ga Batch / Serial number: BBCCDDYYZZXXXXX where:
BB = product variant e.g. TT, LD or VB CC = Major revision DD = region e.g. 02 for US / Canada YY = year of manufacture e.g. 20 for 2020 ZZXXXXX = Individual Identifier e.g. AA00001, where:
ZZ = Production Batch ID XXXXX = Individual Identifier is in conformity with Part 15 of the FCC Rules:
Operation is subject to the following two conditions:
1. this device may not cause harmful interference, and 2. this device must accept any interference received, including interference that may cause undesired op-
eration. The following test reports are subject to this declaration:
Test Report Number Issue Date
The following manufacturer/importer/entity (located in the USA) is responsible for this declaration:
Company Name Name / Title (legal representative) Address Phone Fax E-Mail Date:
Signature
Signature Name: N. Herrwerth Function: Managing Director Document name: TWTG-DoC-EU-01092022 Effective date of this document: 27-06-2022
1 2 | Declaration of authorization | Cover Letter(s) | 41.77 KiB | December 16 2022 / December 20 2022 |
RF_160, Issue 04 Declaration of Authorization We Name:
Address:
City:
Country:
Declare that:
TWTG R&D B.V. Schaardijk 386 Capelle a/d IJssel, 2909 LA The Netherlands Name Representative of agent: Wesley Kerstens (1) Agent Company name:
Address:
City:
Country TWTG R&D B.V. Schaardijk 386 Capelle a/d IJssel, 2909 LA The Netherlands is authorized to apply for Certification of the following product(s):
Product description: Wireless LoRa-WAN transmitter + connected sensor(s) Type designation: DS-02 TWTG Trademark:
on our behalf. Date:
City:
Name:
25-03-2022 Capelle aan den IJssel Dimer Schaefer (2) Function:
COO Signature:
. Notes:
(1): Required for FCC application
(2): For FCC it must be the Grantee Code owner or the authorized agent.
1 2 | Test Report P000052180 001 Ver 3.10 | Test Report | 1.76 MiB | December 16 2022 / December 20 2022 |
1 2 | Test Report P000052180 002 Ver 3.00 | Test Report | 636.73 KiB | December 16 2022 / December 20 2022 |
1 2 | Test Report P000052180 003 Ver 2.00 | Test Report | 776.01 KiB | December 16 2022 / December 20 2022 |
1 2 | Test Setup Photos | Test Setup Photos | 866.46 KiB | December 16 2022 / March 01 2023 | delayed release |
1 2 | confidentiality | Cover Letter(s) | 168.39 KiB | December 16 2022 / December 20 2022 |
Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Colombia, MD 21046 USA Subject; Confidentiality request FCC ID: 2ATYF-DS02 Date: 27 June 2022 To Whom It May Concern, Pursuant to the provisions of the Commissions rules Title 47 Sections 0.457 and 0.459,TWTG R&D B.V. respectfully requests to withhold the following documents as confidential from public disclosure indefinitely:
Block diagrams;
Schematic diagrams;
Bill of material;
Operational description. These documents contain detailed system descriptions and are considered as proprietary information regarding the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. To ensure that business sensitive information remains confidential until the marketing of the equipment, we would like to request short term confidentiality for the following documents until the date mentioned in form 731:
External photos;
Internal photos;
User manuals;
Test setup photos. Sincerely, Signature:
Name: Wesley Kerstens Title: Embedded hardware lead Schaardijk 386, Capelle a/d IJssel Rotterdam, the Netherlands, 2909 LA Tel: +31 10 203 7905
1 2 | RF Exposure Info | December 16 2022 / December 20 2022 |
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2022-12-20 | 902.3 ~ 914.9 | DSS - Part 15 Spread Spectrum Transmitter | Original Equipment |
2 | 903 ~ 914.2 | DTS - Digital Transmission System |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 | Effective |
2022-12-20
|
||||
1 2 | Applicant's complete, legal business name |
TWTG R&D BV
|
||||
1 2 | FCC Registration Number (FRN) |
0028637296
|
||||
1 2 | Physical Address |
Schaardijk 386
|
||||
1 2 |
Capelle aan den IJssel, N/A
|
|||||
1 2 |
Netherlands
|
|||||
app s | TCB Information | |||||
1 2 | TCB Application Email Address |
c******@telefication.com
|
||||
1 2 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 2 | Grantee Code |
2ATYF
|
||||
1 2 | Equipment Product Code |
DS02
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 | Name |
D**** S****
|
||||
1 2 | Title |
Mr
|
||||
1 2 | Telephone Number |
+3110********
|
||||
1 2 | Fax Number |
0********
|
||||
1 2 |
d******@twtg.io
|
|||||
app s | Technical Contact | |||||
1 2 | Firm Name |
TWTG R&D B.V.
|
||||
1 2 | Name |
W**** K****
|
||||
1 2 | Physical Address |
386, Schaardijk
|
||||
1 2 |
Netherlands
|
|||||
1 2 | Telephone Number |
31 10********
|
||||
1 2 |
w******@twtg.io
|
|||||
app s | Non Technical Contact | |||||
1 2 | Firm Name |
TWTG R&D B.V.
|
||||
1 2 | Name |
D**** S****
|
||||
1 2 | Physical Address |
386, Schaardijk
|
||||
1 2 |
Netherlands
|
|||||
1 2 | Telephone Number |
31 10********
|
||||
1 2 |
d******@twtg.io
|
|||||
app s | Confidentiality (long or short term) | |||||
1 2 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 03/01/2023 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 | Equipment Class | DSS - Part 15 Spread Spectrum Transmitter | ||||
1 2 | DTS - Digital Transmission System | |||||
1 2 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Wireless LoRa-WAN transmitter + connected sensor(s) | ||||
1 2 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 | Modular Equipment Type | Does not apply | ||||
1 2 | Purpose / Application is for | Original Equipment | ||||
1 2 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | Yes | ||||
1 2 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 | Grant Comments | Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. | ||||
1 2 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 | Firm Name |
Kiwa Nederland B.V.
|
||||
1 2 | Name |
W**** J********
|
||||
1 2 | Telephone Number |
+31 8********
|
||||
1 2 |
d******@kiwa.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 902.30000000 | 914.90000000 | 0.0042000 | ||||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 15C | 903.00000000 | 914.20000000 | 0.0040000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC