all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 2.07 MiB | ||||
1 | Cover Letter(s) | |||||||
1 | External Photos | |||||||
1 | Test Report | |||||||
1 | Internal Photos | |||||||
1 | Cover Letter(s) | |||||||
1 | Cover Letter(s) | |||||||
1 | Cover Letter(s) | |||||||
1 | ID Label/Location Info | |||||||
1 | Test Setup Photos |
1 | User Manual | Users Manual | 2.07 MiB |
Do not discard!
This document may be required by code inspectors. Leave it at the site until the installation is complete and the system has been approved. Ultra 1.5 meter ABS Pedestal System Installation Guide ZS1146-P, ZS1146-S, ZA1146-D 2018 Sensormatic Electronics, LLC ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 1 of 44 8200-1048-06, REV. A
*8200-1048-06*
Contents About this guide ............................................................................................................................................... 3 About the Ultra 1.5 meter ABS Pedestal System .......................................................................................... 3 Kit parts ......................................................................................................................................................... 4 Supported configurations .............................................................................................................................. 5 Coverage distances ...................................................................................................................................... 5 Compatibility .................................................................................................................................................. 5 Safety ............................................................................................................................................................ 6 Installation overview ........................................................................................................................................ 8 Section I: Before you begin ............................................................................................................................. 9 Planning the location of system components ................................................................................................ 9 Installation requirements ............................................................................................................................. 10 System requirements .................................................................................................................................. 11 Section II: Installation .................................................................................................................................... 12 Overview of installation steps ...................................................................................................................... 12 Step 1: Removing the pedestal covers ....................................................................................................... 12 Step 2: Positioning the pedestals ................................................................................................................ 12 Step 3: Routing the cables .......................................................................................................................... 13 Step 4: Securing the pedestal to the floor ................................................................................................... 14 Section III: Connecting the Ultra 1.5m ABS Pedestal ................................................................................. 15 Overview of connection steps ..................................................................................................................... 15 Step 1: Connecting the primary pedestal .................................................................................................... 15 Step 2: Connecting the secondary pedestal ............................................................................................... 17 Step 3: Connecting AC power ..................................................................................................................... 18 Step 4: Tuning the Ultra 1.5 meter ABS Pedestal System ......................................................................... 22 Step 5: Checking EAS performance ........................................................................................................... 28 Step 6: Adjusting the audio alarm ............................................................................................................... 28 Step 7: Installing the pedestal covers ......................................................................................................... 28 Step 8: Covering the antenna cables .......................................................................................................... 29 Step 9: Applying anti-theft labels in other languages .................................................................................. 29 Step 10: Cleaning the pedestal ................................................................................................................... 29 Field replaceable units................................................................................................................................... 30 Boot Loader Mode .......................................................................................................................................... 30 Specifications ................................................................................................................................................. 32 Declarations .................................................................................................................................................... 33 Appendix A: Dimensions ............................................................................................................................... 34 Appendix B: Connecting an Auxiliary Receiver .......................................................................................... 35 Appendix C: Connecting an UltraLink ......................................................................................................... 36 Appendix D: Connecting a Local Device Manager ..................................................................................... 39 Appendix E: Connecting a Digital Remote Alarm ....................................................................................... 41 Appendix F: Main board pinouts .................................................................................................................. 44 ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 2 of 44 8200-1048-06, REV. A
*8200-1048-06*
About this guide This installation guide explains how to install the Ultra 1.5 meter ABS Pedestal System. You must install the Ultra 1.5 meter ABS Pedestal System as outlined in this guide. Other related documents that can help you with this installation, include the following:
CBC-4055 Local Device Manager Installation Guide, 8200-0858-01 CBC-4020 UltraLink Indoor Installation and Service Guide, 8200-0172-01 AMC-1060 Digital Remote Alarm Installation Guide, 8200-0505-01 Customer requirements dictate the placement of system components. Your Sensormatic representative supplies this information separately. Regulatory restriction: For indoor use only. Intended use: Only install this device as described in this guide. If this product was installed in a European Union or European Free Trade Association member state, give the Declaration of Conformity included with this product to the manager or user. By law, you must provide this information to the user. Technical support For product bulletins, and the most recent updates to this document, visit https://sensormaticsecurelogin.com. About the Ultra 1.5 meter ABS Pedestal System The Ultra 1.5 meter ABS Pedestal System described in this document activates an alarm when it detects the unique response of an active UltraMax hard tag or disposable label. The Ultra 1.5 meter ABS Pedestal System consists of two pedestal antennas, a primary and a secondary, connected by an interconnect cable. The primary pedestal connects to a power source and has an alarm board and the main controller board. The secondary pedestal does not have a LED alarm indicator; it has the lens cover and contains a receiver board. Product features The Ultra 1.5 meter ABS Pedestal System is similar to the UltraShield systems, but the system has the following additional features:
An aesthetic look that meets and exceeds competitive offerings. Supports single and dual configurations. Jammer detection. Tags-too-close. Network connectivity through the use of a Local Device Manager (LDM). The system has a single door coverage capability of 0.9 meters or 3 feet, and a double door coverage Integrated audio and visual alarming in the primary pedestal. capability of 1.5 meters, or 5 feet. ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 3 of 44 8200-1048-06, REV. A
*8200-1048-06*
Kit parts This section outlines the components you require to install the Ultra 1.5 meter ABS Pedestal System. Ultra 1.5 meter ABS Pedestal System Table 1 lists the kit parts you require to install the Ultra 1.5m ABS Single Pedestal System, ZS1146-P. Table 2 lists the kit parts you require to install the Ultra 1.5m ABS Secondary Pedestal System, ZS1146-S. Table 3 lists the kit parts you require to mount the Ultra 1.5 meter ABS Pedestal System. Table 1. Ultra 1.5m ABS Single Pedestal System, ZS1146-P Kit Primary pedestal assembly with cover Pedestal mounting installation kit Product code 0304-3039-01 0352-0781-01 Quantity required 1 1 Table 2. Ultra 1.5m ABS Secondary Pedestal System, ZS1146-S Kit Secondary pedestal assembly with cover Pedestal mounting installation kit Product code 0304-3040-01 0352-0781-01 Quantity required 1 1 Table 3. Pedestal Mounting Installation Kit, 0352-0781-01 Part Washer flat Anchors expansion, 5/16 x 1-3/4 Bolt, lag, 5/16 x 2.5, 1/2" Hex Screws, Hex, M6 x 60 Washer, flat, M8 Part number 2848-0025-01 2880-0105-01 2880-0106-01 5801-4174-520 5840-0700-020 Quantity required 4 4 4 2 2 Interconnect cable options for the Ultra 1.5 meter ABS Pedestal System Interconnect cables connect the primary and the secondary pedestal. Table 4 lists the kit parts you require to install the 4 meter interconnect cable. Table 5 lists the kit parts you require to install the 12 meter interconnect cable. Table 6 lists the kit parts you require to install the 15 meter interconnect cable. Table 4. AMS-1146 4M TX Interconnect Cable Installation Kit, 0352-0792-01 Item Cable Assembly, transceiver Part number 0652-0789-01 Quantity required 1 Table 5. AMS-1146 12M TX Interconnect Cable Installation Kit, 0352-0793-01 Item Cable Assembly, transceiver Part number 0652-0789-02 Quantity required 1 Table 6. AMS-1146 15M TX Interconnect Cable Installation Kit, 0352-0794-01 Item Cable Assembly, transceiver Part number 0652-0789-03 Quantity 1 ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 4 of 44 8200-1048-06, REV. A
*8200-1048-06*
Supported configurations The Ultra 1.5 meter ABS Pedestal System supports single and dual configurations. Coverage distances Table 7 lists the exit coverage capabilities of the Ultra 1.5 meter ABS Pedestal System. Table 7. Ultra 1.5 meter ABS Pedestal System exit coverage capabilities Ultra 1.5 meter ABS Pedestal System configuration Single Dual alternating Exit coverage distance 0.9 meters, or 3 feet 1.5 meters, or 5 feet Compatibility The Ultra 1.5 meter ABS Pedestal System is compatible with the following products:
Ranger Antennas Satellite Antennas Amorphous Core Receiver Note: Compatible with one Amorphous Core Receiver only, not a pair of receivers. Digital Remote Alarm (DRA) Ultra Link Local Device Manager (LDM) Wireless Device Manager (BIM1000) and the Wireless Device Module (BIX1000) ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 5 of 44 8200-1048-06, REV. A
*8200-1048-06*
Safety Installation requirements Intended use: Only install this device as described in this guide. The installer or contractor must adhere to the following criteria:
Have electrical work comply with the latest national electrical code, national fire code, and all applicable local codes and ordinances. National or local wiring codes or rules can differ between regions. Adherence to these codes supersedes instructions in this document. Coordinate all work with other trades to avoid interference. Verify existing site conditions and coordinate with the owners representative and appropriate utilities as required. Obtain copies of all related plans, specifications, shop drawings and addenda to schedule and coordinate related work. Thoroughly review the project to ensure that all work meets or exceeds the above requirements. The installer or contractor must bring any alleged discrepancies to the attention of Sensormatic Electronics. Chemical interaction WARNING: Do not install this product in hazardous areas where highly combustible or explosive products are stored or used. Cabling WARNING: Risk of electric shock During installation, if the antenna must be left unattended, turn off power or cover high voltage components to prevent unauthorized access to hazardous voltages. WARNING: Risk of electric shock The AC power could be carrying 120Vac or 240Vac. WARNING: Risk of electric shock The transmit pedestal contains hazardous voltages. If the pedestal must be left unattended with its high voltage components exposed, turn off power or cover these components to avoid unauthorized persons access to hazardous voltages. WARNING: Do not run the power and comm cables in the same conduit or raceway. Building codes require that power wiring be separated from other types of wiring. WARNING: In accordance with the USA National Electric Code and applicable US local codes, a 15A or 20A, 2 pole, ganged disconnect device, which also provides short circuit and overload protection and has a minimum 3 millimeter open circuit clearance, must be installed by a licensed electrician at a location readily accessible to the equipment. For installations in other countries, an electrical outlet, suitable for the voltage and current used in the primary electrical supply input of the equipment, must be already provided or installed by a qualified electrician. The National Electric Codes, regulations, cable, and fusing requirements applicable for the equipment and type of installation must be followed at all times. ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 6 of 44 8200-1048-06, REV. A
*8200-1048-06*
CAUTION: The AC source must be a two-wire plus ground, 24-hour, unswitched outlet with less than 0.5Vac between neutral and ground. CAUTION: For permanently connected equipment, a 15A or 20A, two-pole, ganged disconnect device, which also provides short circuit and overload protection, and has a minimum 3 millimeter open circuit clearance, in accordance with the National Electric Code and applicable local codes must be installed by a licensed electrician at a location readily accessible to the equipment. CAUTION: For pluggable equipment, the socket-outlet shall be installed near the equipment and shall be easily accessible. Important:
Do not share the AC source with neon signs, motors, computers, cash registers, terminals, or data communications equipment. Do not use orange-colored outlets dedicated for computer equipment. CAUTION: For continued protection against risk of fire, replace fuse only with same type and rating. Implanted medical devices This anti-theft system complies with all applicable safety standards. However, people with implanted electronic medical devices can ask if the store has an anti-theft system, and its location. Although most anti-theft systems are easily seen, some can be concealed. To help individuals with implanted medical devices, consider the following health and safety guidelines:
Health and safety Place the anti-theft system antennas to ensure customers behave in the following ways:
Do not linger near, or lean on them while making their purchase. Are only near the front of them while exiting the checkout area. For exit systems, place anti-theft system antennas:
Close to exit and entrance doors, encouraging the customer to pass through them. Do not use antennas intended for exits in an aisle configuration. Away from fixtures, equipment, amusements, and other signage that can attract customers to them. Apply Anti-theft signage Anti-theft labels are placed on each antenna, including those hidden behind door frames and other structures. Do not cover these labels with other signage. In non-English speaking countries, apply Anti-theft labels in the local language to the antennas. For hidden antennas, apply an Anti-theft label in the local language to each side of the door frame facing the doorway about 1.2 meters or 4 feet above the floor. You can order local language labels, 2412-0170-XX, from your distribution center. To improve customer awareness of the anti-theft system, encourage the store to display signs that state it has an anti-theft system. You can order awareness materials through your sales representative. ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 7 of 44 8200-1048-06, REV. A
*8200-1048-06*
Installation overview Figure 1 gives an overview of the installation sequence you must follow when installing the Ultra 1.5 meter ABS Pedestal System. Figure 1. Ultra 1.5 meter ABS Pedestal System installation overview Section I:
Before you begin Section II:
Installation Section III:
Connecting the system Complete all the prerequisites in Section I before you install the Ultra 1.5 meter ABS Pedestal System. Install the system components for the Ultra 1.5 meter ABS Pedestal System. Connect the Ultra 1.5 meter ABS Pedestal System components, and verify that they work. ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 8 of 44 8200-1048-06, REV. A
*8200-1048-06*
Section I: Before you begin This section outlines the criteria you must adhere to when you install the Ultra 1.5 meter ABS Pedestal System. Training Do not attempt to install the Ultra 1.5 meter ABS Pedestal System unless you have completed the Ultra 1.5 meter ABS Pedestal System Training webinar. To schedule a webinar or in class training, contact your regional training representatives. Planning the location of system components This section outlines how to determine the location for the components of the Ultra 1.5 meter ABS Pedestal System. Pedestal location Consider the following criteria when you select the location of the Ultra 1.5 meter ABS Pedestal System:
Whenever possible, keep the antennas at least 2.4 meters, or 8 feet away from noise sources such as computer monitors, TVs, switching power supplies, and neon displays. Maximum exit coverage of one primary pedestal is 0.9 meters, or 3 feet. The pedestals can protect a space 1.5 meters, or 5 feet wide between them, the primary pedestal also detects 90 centimeters, or 3 feet behind for total exit coverage of 2.4 meters, or 8 feet. The maximum distance between the primary and the secondary pedestals is 1.5 meters or 5 feet, measured from pedestal center to pedestal center. The minimum distance between two pedestals is 0.6 meters or 2 feet, measured center to center. If you must route the interconnect cable over the top of the doors, the maximum cable distance between the pedestals is either 15 meters, or 50 feet, or 12 meters, or 40 feet, depending on which cable option the pedestal has. You usually route the supplied 4 meter or 13 feet cable in the floor. A transmit field is emitted from both sides of the primary pedestal. Unless you are using backfield reduction configuration, keep displays that are tagged at least 1.5 meters or 5 feet, from the pedestal, especially when using the tag-too-close function. You mount the pedestal to the floor using the four anchors in the AMS-1146 Pedestal Mounting Installation Kit, 0352-0781-01. Cable openings in the pedestal base allow for cable entry from underneath the pedestal or from either end of the pedestal through a cutaway in the base covers. Cable access can be through conduit or Wiremold. AMC-1060 Digital Remote Alarm If you are using an AMC-1060 Digital Remote Alarm with the Ultra 1.5 meter ABS Pedestal System, consider the following criteria:
The Ultra 1.5 meter ABS Pedestal System does not provide power for the AMC-1060 Digital Remote Alarm, because the system does not provide power, you need a nearby power outlet. If installing an AMC-1060, confirm the location of the power outlet before you run the wires. Plug the 12V DC transformer used to power the alarm, into a 24-hour unswitched outlet. The maximum cable distance from the primary pedestal to each remote alarm is about 12.2 meters, or 40 feet. ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 9 of 44 8200-1048-06, REV. A
*8200-1048-06*
Installation requirements This section outlines the installation requirements you require to install the Ultra 1.5 meter ABS Pedestal System. Tool requirements You require the following tools and equipment to install the Ultra 1.5 meter ABS Pedestal System:
0.15 millimeters or 6 mils minimum plastic sheeting to protect nearby items from dust A permanent marker or pencil A power drill with 1 cm, or 3/8 inch masonry drill bit A hammer Phillips and slotted screwdrivers A wire stripper Pancake conduit or floor saw and floor-fill material A ratchet and socket set A utility knife A level A hand vacuum and broom Equipment requirements You require the following equipment to install the Ultra 1.5 meter ABS Pedestal System:
The Ultra 1.5 meter ABS Pedestal System, ZS1146-P or, ZS1146-S The Ultra 1.5 meter ABS Pedestal System Mounting Installation Kit, 0352-0781-01 One of the following TX Interconnect Cable Interconnect Kits:
o The 4 meter TX Interconnect Cable Interconnect Kit, 0352-0792-01 o The 12 meter TX Interconnect Cable Interconnect Kit, 0352-0793-01 o The 15 meter TX Interconnect Cable Interconnect Kit, 0352-0794-01 A hard tag, non-deactivatable UltraMax tag, or UltraMax low energy labels. A laptop computer with Windows 7 operating system, Internet Explorer 11, or Mozilla Firefox A RS-232 UltraMax programming cable A USB to RS-232 converter, if required Note: For more information on the USB to RS232 converter cable for EAS configurator communication, see the TB150807 USB to RS232 Converter for EAS PDF, available online at https://sensormaticsecurelogin.com. Unpacking and checking equipment Complete the following checks when unpacking and verifying the equipment:
Verify that all equipment is included. Ensure the Ultra 1.5m ABS Pedestal configuration is the correct one for the installation site. Unpack the major components in a space where you are not obstructing or causing nuisance to customers. At the install site, lay out the parts in the order you require them. Do not clutter the aisle, or cause a trip hazard. ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 10 of 44 8200-1048-06, REV. A
*8200-1048-06*
System requirements This section outlines the system requirements you require to install the Ultra 1.5 meter ABS Pedestal System. Laptop requirements You require the following items for your laptop:
A laptop computer with Windows 7 operating system and the latest Internet Explorer, or Mozilla Firefox browser installed. A USB to RS-232 converter, if required. An RS-232 UltraMax programming cable. Firmware requirements In order to support the installation of the Ultra 1.5 meter ABS Pedestal System, you must download the latest firmware bundle from https://sensormaticsecurelogin.com/. Table 8 lists the firmware you require to install the Ultra 1.5 meter ABS Pedestal System. Table 8. Firmware you require to install the Ultra 1.5 meter ABS Pedestal System Compatible firmware Ultra 1.5 meter ABS Pedestal System firmware CE ADS4 Platform Configurator Version Version 1.0014 or higher Version 9.20 Build 16 or higher To download the latest configurator, complete the following steps:
1. Open a web browser and launch the https://sensormaticsecurelogin.com/ webpage. 2. Enter your valid log-in details, and click Login. 3. From the Tech Support menu, select EAS. 4. Select Software Download. 5. From the Technology list, select Detectors. 6. Download the latest bundle. ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 11 of 44 8200-1048-06, REV. A
*8200-1048-06*
Section II: Installation This section outlines how to install the Ultra 1.5 meter ABS Pedestal System. Overview of installation steps The following list outlines the steps you must complete to install the Ultra 1.5 meter ABS Pedestal System. Step 1: Remove the pedestal covers Step 2: Position the pedestals Step 3: Route the cables Step 4: Secure the pedestal to the floor Step 1: Removing the pedestal covers To remove the pedestal covers from the Ultra 1.5 meter ABS Pedestal System, complete the following procedure:
1. At the top of the pedestal, squeeze the area below the alarm lens, and gently pull on the lens to remove it from the cover. CAUTION: You must remove the alarm lens gently. Using force to remove the lens from the pedestal cover can cause the lens to break, or damage to the alarm board LED. 2. Loosen the two captive screws securing the pedestal base covers. 3. Gently prize the pedestal covers apart. 4. Remove the pedestal cover and set it aside. Step 2: Positioning the pedestals To mark the locations for the Ultra 1.5 meter ABS Pedestal System and position the pedestals, complete the following steps:
1. Lift the pedestal from the pedestal base, and set it aside. 2. Determine the location of the Ultra 1.5 meter ABS Pedestal System, as described in Pedestal location on page 9. 3. Note the location of the power source or the conduit stub where you will place the primary pedestal. WARNING: In accordance with the USA National Electric Code and applicable US local codes, a 15A or 20A, 2 pole, ganged disconnect device, which also provides short circuit and overload protection and has a minimum 3 millimeter open circuit clearance, must be installed by a licensed electrician at a location readily accessible to the equipment. For installations in other countries, an electrical outlet, suitable for the voltage and current used in the primary electrical supply input of the equipment, must be already provided or installed by a qualified electrician. The National Electric Codes, regulations, cable, and fusing requirements applicable for the equipment and type of installation must be followed at all times. 4. Position the primary pedestal in its exact mounting location. ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 12 of 44 8200-1048-06, REV. A
*8200-1048-06*
5. Position the secondary pedestal no more than 1.5 meters, or 5 feet from the primary pedestal. CAUTION: Do not space Ultra 1.5 meter pedestals more than 1.5 meters, or 5 feet apart. 6. Use the pedestal base as a template, and mark the locations for the four mounting holes. For the pedestals footprint dimensions, see Appendix A: Dimensions, on page 34. 7. Optional: If you are burying the interconnect cable in the ground, mark the location of the interconnect cable entry hole. 8. Remove the pedestals, and using a drill with a 1.25 centimeter or 1/2-inch masonry bit, drill four 7.6 centimeters or 3-inch deep mounting holes in the floor for each base. Note: If drilling through carpet, to prevent carpet runs, first mark the holes then cut out the carpet plugs where the holes will be. Step 3: Routing the cables To route the cables for the Ultra 1.5 meter ABS Pedestal System, complete the following steps:
WARNING: Risk of electric shock Disconnect power from the primary pedestal before you proceed. The AC power line could be carrying 120Vac or 240Vac. Route cables underneath and around the controller board on the primary pedestal, and the receiver board on the second pedestal, using the cabling guide on the pedestal chassis to keep them away from high voltage. 1. Route the cables using the appropriate length of cable: 4 meters or 13.1 feet, 12 meters or 39.3 feet, or 15 meters or 49.2 feet, and then select one of the following options:
If you are routing the cable over the doorway, route the cable as shown in Figure 2. Figure 2. Routing the cable over a doorway ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 13 of 44 8200-1048-06, REV. A
*8200-1048-06*
If you are trenching the floor between the pedestals, ensure the proposed trench extends under the pedestal location so cables can enter the pedestal from its base underneath. Then, using a floor saw, trench the floor from pedestal to pedestal. The depth of the trench is 1 centimeter, or 3/8 inches. The width of the trench is 1 centimeter, or 3/8 inches. Important: Direct burial without conduit is not permitted in European Union (EU) countries. 2. Note: Skip this step, if you are installing only a single primary pedestal. Run the interconnect cable between the primary and secondary pedestal and up through the base. The interconnect cable can enter the base either through the strain-relief on the bottom of the base or from the center of the side. 3. Route the AC cable to the primary pedestal through the conduit access hole in the base. WARNING: Do not run the power and interconnect cable in the same conduit or raceway. Building codes require that power wiring be separated from other types of wiring. 4. If you are installing an optional device, for example, a digital remote alarm or auxiliary receivers, run the device cable or cables up through the base of the primary pedestal, and along the side of the pedestal using the cabling guide on the pedestal chassis. Important: The Ultra 1.5 meter ABS Pedestal System does not provide power for the AMC-1060 Digital Remote Alarm. Because the system does not provide power, you need a nearby power outlet to support the required AC adapter. Confirm the location of the power outlet before you run the wires. Important: The maximum cable distance from the primary pedestal to each remote alarm is about 12.2 meters, or 40 feet. If you are connecting a digital remote alarm to the system, the wire you use to connect the digital remote alarm to the pedestal must be shielded, and you must connect the shield wire at both ends. Step 4: Securing the pedestal to the floor To secure the Ultra 1.5 meter pedestal to a floor, complete the following steps:
1. Level the pedestal base, or bases. 2. Locate the anchor wedges, 2880-0105-01, from the Pedestal Mounting Installation Kit, 0352-0781-01. Insert the anchor wedges into the holes in the floor, and tap the anchors into the holes. 3. Place the pedestal over the four protruding anchors in the floor. 4. Secure each pedestal base to the floor using the four screws, 5801-4174-520, and the four anchors, 2880-
0105-01, from the Pedestal mounting installation kit, 0352-0781-01. 5. Locate the pedestal that you previously set side, and slip the pedestal over the pedestal base. ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 14 of 44 8200-1048-06, REV. A
*8200-1048-06*
Section III: Connecting the Ultra 1.5m ABS Pedestal This section outlines how to connect the cables and wire the Ultra 1.5 meter ABS Pedestal System. Overview of connection steps The following list outlines the steps you must complete to connect and wire the Ultra 1.5 meter ABS Pedestal System:
Step 1: Connect the primary pedestal Step 2: Connect the secondary pedestal Step 3: Connect AC power Step 4: Tune the Ultra 1.5 meter ABS Pedestal System Step 5: Check EAS performance Step 6: Adjusting the audio alarm Step 7: Install the pedestal covers Step 8: Cover the antenna cables Step 9: Apply anti-theft labels in other languages Step 10: Clean the pedestal Step 1: Connecting the primary pedestal To connect the cables to the controller board of the primary pedestal, complete the following steps:
1. Note: Skip this step, if you are installing only a single primary pedestal. On the main controller of the primary pedestal, attach the interconnect cable to the 5-position Euro-style connector which is plugged into connector P6. For the connections, see Table 9 and Figure 3. For the location of the P6 connector, see Figure 4. Table 9. Primary pedestal interconnect cable connections Pin 1 2 3 4 5 Signal name Top coil Top coil return Bottom coil Bottom coil return Shield Color Black Red Green White Shield Figure 3. Connecting the interconnect cable ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 15 of 44 8200-1048-06, REV. A
*8200-1048-06*
Figure 4. P6, P5, and top and bottom coil locations on the main controller board A D B C A B Bottom coil connector, P3 Top coil connector, P1 C D Connector P5 location Secondary P6 Note: If you are replacing the main board, connect P1, P3 and P5 alarm cable. 2. On the primary pedestal, plug the alarm cable 0652-5812-01, into connector P5 of the controller board. 3. Attach the 3-position connector to the upper antenna coil cable as shown in Table 10. Plug the cable into the top coil connector, P1, on the controller board. Table 10. Antenna top coil connections Color Pin 1 Black Red 2 3 White Signal name Primary top coil return Shield Primary top coil 4. Attach the 3-position connector to the lower antenna coil cable as shown in Table 11. Plug the cable into the bottom coil connector, P3, on the controller board. Table 11. Antenna bottom coil connections Pin 1 2 3 Color Black Red White Signal name Primary top coil return Shield Primary top coil ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 16 of 44 8200-1048-06, REV. A
*8200-1048-06*
Step 2: Connecting the secondary pedestal To connect the cables to the receiver board on the secondary pedestal, complete the following step:
WARNING: Risk of electric shock Disconnect power from the primary pedestal before you proceed. On the receiver board of the secondary pedestal, attach the interconnect cable to the 5-position Euro-
style connector which is plugged into connector P2. For the connections, see Table 12 and Figure 5. For the location of the P2 connector, see Figure 6. Table 12. Secondary pedestal receiver cable connections Pin 1 2 3 4 5 Figure 5. Connecting the interconnect cable Color Black Red Green White Shield Signal name Top coil Top coil return Bottom coil Bottom coil return Shield Figure 6. P1, P2 and P3 locations on the receiver board B A C C Connector P3 location A B Connector P1 location Connector P2 location ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 17 of 44 8200-1048-06, REV. A
*8200-1048-06*
If you are replacing the secondary receiver board, you must complete the following steps:
1. Attach the 3-position connector to the upper antenna coil cable as shown in Table 13. Plug the cable into the top coil connector, P1, on the receiver board. Table 13. Secondary antenna top coil connections Pin 1 2 3 Color Black Red White Signal name Secondary top coil return Shield Secondary top coil 2. Attach the 3-position connector to the lower antenna coil cable as shown in Table 14. Plug the cable into the bottom coil connector, P3, on the receiver board. Table 14. Secondary antenna bottom coil connections Pin 1 2 3 Color Black Red White Signal name Secondary bottom coil return Shield Secondary bottom coil Step 3: Connecting AC power To connect the system to AC power, complete the following steps:
CAUTION: A 15A, two-pole, ganged disconnect device, which also provides short circuit and overload protection, and has a minimum 3 millimeter open circuit clearance, in accordance with the National Electric Code and applicable local codes must be installed by a licensed electrician at a location readily accessible to the equipment. If the only line providing power is the primary/L1, you can use a single-pole breaker. 1. Locate the voltage shunt, 2109-0062-01, which is in a bag taped inside the primary pedestal enclosure. WARNING: Risk of electric shock Ensure that the system is not powered before moving the shunts. 2. Select the proper voltage for the site using the shunt, 2109-0062-01. The default setting is 240Vac. For the location of J5, see Figure 8. Figure 7. Voltage settings and shunts 120 Vac: J5 shunt IN 240 Vac (Default): J5 shunt OUT ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 18 of 44 8200-1048-06, REV. A
*8200-1048-06*
Figure 8. J5 location on the capacitor board A A J5 WARNING: Risk of electric shock Ensure that the circuit breaker for the power cable is off before connecting the pedestal to AC power. The AC power cord may carry 120Vac or 240Vac. CAUTION: You can not use a power cord with the Ultra 1.5 meter ABS Pedestal System. You must hardwire the system. 3. Connect the pedestal to AC power by hard-wiring the system. 4. Complete the following steps to remove the metal drip plate:
a. Locate the screw securing the drip plate to the pedestal, as shown in Figure 9. b. Unscrew the screw from the drip plate, and set the drip plate aside for later use. Figure 9. Metal drip plate screw ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 19 of 44 8200-1048-06, REV. A
*8200-1048-06*
5. Loosen the ground screw, positioned to the right of the power connector. For the location of the ground screw, see Figure 10. Figure 10. Wiring the power connector A D B C C D Ground jumper, ground point Ground screw A B Line Neutral 6. Route the AC power cord up the right side of the pedestal base. 7. Connect the AC power wires to the power connector on the main controller board. Connect the Line wire
(black) to L, the Neutral wire (white) to N, and the Ground wire (green) to the ground screw on the main controller board, as shown in Figure 10. Note: The power connector accepts 0.75 to 2.0 mm2 (18 to 14 AWG) wire. Important: If you remove the connector, do not pull it out by the wires; pull on the connector. 8. Tighten the ground screw, and secure the Ground wire (green). Note: When connecting the ground wire, ensure the slot on the washer is pointing down to allow the jacket on the cable to fit behind the washer. See Figure 11. Figure 11. Connecting the Ground wire WARNING: After tightening the ground wire screw, carefully inspect the ground wire to insure that no wire strands are touching any components on the board. ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 20 of 44 8200-1048-06, REV. A
*8200-1048-06*
9. Reattach the metal drip plate positioning the wires behind the access slot, as shown in Figure 12. WARNING: Risk of electric shock When reattaching the drip plate do not to damage or pinch any cables routed behind it. Ensure the cables route up through the access slot. Figure 12. Routing the cables WARNING: Do not run the power and comm cables in the same conduit or raceway. Building codes require that power wiring be separated from other types of wiring. ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 21 of 44 8200-1048-06, REV. A
*8200-1048-06*
Step 4: Tuning the Ultra 1.5 meter ABS Pedestal System The goal of tuning is to adjust the total capacitance on the capacitor board until the current amplitudes in the top and bottom coils are maximized. WARNING: Risk of electric shock High-voltage AC is present on the Cap board whenever the pedestal power is on. Ensure that the system is not powered before touching the tuning jumpers. Before you tune the Ultra 1.5 meter ABS Pedestal System Tuning jumpers are used to adjust the total capacitance of the antennas. The main controller board on the primary pedestal has two groups of tuning jumpers: JW6-JW8 and JW12 for the top coil, and JW9-JW11 and JW13 for the bottom coil. The secondary pedestal requires no tuning. Before applying power to the antenna and tuning the primary pedestal, complete the following steps:
1. Verify the board is properly seated and all cables are securely connected. 2. Ensure the tuning jumpers are in their default tuning positions on the primary pedestal. See Table 17 and Figure 17 on page 27. Tuning the Ultra 1.5 meter ABS Pedestal System To tune the Ultra 1.5 meter ABS Pedestal System, complete the following steps:
WARNING: Risk of electric shock High-voltage AC is present on the Cap board whenever the pedestal power is on. Ensure that the system is not powered before touching the tuning jumpers. 1. Supply power to the system. 2. Connect your laptop computer to the RS-232 service port, J2, on the primary controller board. For the location of the J2 service port, see, Appendix F: Main board pinouts on page 44. 3. Launch the CE ADS4 Platform Configurator. 4. Click the TX Configuration tab. See Figure 13, on page 23. 5. In the Misc. TX Settings area, select the following parameters for the antenna:
Ant Polarity: Aiding TX Frequency: Nominal CAUTION:
After you have finished tuning the pedestal, you must return the Misc. TX Settings to previous values to return the pedestals to their normal operating modes. ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 22 of 44 8200-1048-06, REV. A
*8200-1048-06*
Figure 13. TX Configuration window 6. Click the Setup tab. From the System Configuration list, select the correct configuration for the site, for example, Prim Transceiver Only. See Figure 14. Figure 14. Setup tab location ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 23 of 44 8200-1048-06, REV. A
*8200-1048-06*
7. From the System menu, click TX Current. This window displays transmit current meters for the antennas. Figure 15. CE ADS4 Platform Configurator System menu 8. On the TX Current window, observe the Top Coil Aiding and the Bottom Coil Aiding meters as you tune the current for the highest amplitude. See Figure 16. Note: The current for the primary pedestal should not exceed 33-40A. Figure 16. TX Current window meters A B C A B Antenna transmit enable checkbox Top Coil Aiding meter C ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 24 of 44 Bottom Coil Aiding meter 8200-1048-06, REV. A
*8200-1048-06*
Tuning the primary pedestal The main controller board has two banks of four jumpers: JW6-JW8 and JW12 for the top coil, and JW9-JW11 and JW13 for the bottom coil. Ensure you are looking at the correct jumpers. For the location of the jumpers see Figure 17, on page 27. Note: The jumper configurations do not have to be the same. The top coil and bottom coil, can have different jumper configurations. Tuning the top coil To tune the top coil on the primary pedestal, complete the following steps:
WARNING: Risk of electric shock Before adjusting jumpers, clear the Antenna check box in the configurator to disable the antenna. After changing the jumper, select the box to re-enable the antenna. 1. From the TX Current window, disable antenna transmission. To disable an antenna transmission, clear the relating check box. 2. Using Table 17 on page 27, set the top coil tuning jumpers to their default tuning positions. 3. Referring to Table 17, reposition the top coil tuning jumpers, JW6-JW8 and JW12, one step up from their default positions. Enable antenna transmission to observe the current meters. 4. If the current increased, add capacitance by completing the following steps:
Important: Before adjusting the jumpers in the following steps, you must clear the antenna check box on the configurator. a. Disable antenna transmission and reposition the top coil tuning jumpers one more step up. b. Enable antenna transmission again and observe the meters. If the current increased again, move another step up in the table. c. Continue until the current displayed on the meter decreases. Then move one step down and reconfigure the top coil tuning jumpers to obtain the highest coil current. Table 15. Target current, top coil Ultra 1.5 meter ABS Pedestal System 33-40A Note: The values of the currents are for a line input of 120Vac and a four meter-long interconnect cable. 5. If current decreased, subtract capacitance by completing the following steps:
Important: Before adjusting the jumpers in the following steps, you must clear the antenna check box on the configurator. a. Disable antenna transmission and reposition the top coil tuning jumpers one step down in the tuning table. b. Enable antenna transmission again and observe the meters. If the current increases, move another step down in the table. c. Continue until the current displayed on the meter decreases. Then move one step up and reconfigure the top coil tuning jumpers to obtain the highest coil current. ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 25 of 44 8200-1048-06, REV. A
*8200-1048-06*
Tuning the bottom coil To tune the bottom coil of the primary pedestal, complete the following steps:
CAUTION:
After you have finished tuning the pedestal, you must return the Misc. TX Settings to their previous values to return the pedestals to their normal operating modes. 1. From the TX Current window, disable antenna transmission. To disable an antenna transmission, clear the relating check box. 2. Using Table 17 on page 27, set the bottom coil tuning jumpers, JW9-JW11 and JW13, to their default tuning positions. 3. Referring to Table 17, reposition the bottom coil tuning jumpers one step up from their default positions. Enable antenna transmission to observe the current meters. 4. If the current increased, add capacitance by completing the following steps:
Important: Before adjusting the jumpers in the following steps, you must clear the antenna check box on the configurator. a. Disable antenna transmission and reposition the bottom coil tuning jumpers one more step up. b. Enable antenna transmission again and observe the meters. If the current increases again, move another step up in the table. c. Continue until the current displayed on the meter decreases. Then move one step down and reconfigure the bottom coil tuning jumpers to obtain the highest coil current. d. When the antenna is properly tuned, return the Misc. TX Settings to their previous values:
Ant A|B|C|D Polarity: Normal TX Frequency: Hopping Table 16. Target current, bottom coil Ultra 1.5 meter ABS Pedestal System 33-40A Note: The values of the currents are for a line input of 120Vac and a four meter long interconnect cable. 5. If the current decreased, subtract capacitance by completing the following steps:
Important: Before adjusting the jumpers in the following steps, you must clear the antenna check box on the configurator. a. Disable antenna transmission and reposition the bottom coil tuning jumpers one step down in the tuning table. b. Enable antenna transmission again and observe the meters. If the current increases, move another step down in the table. c. Continue until the current displayed on the meter decreases. Then move one step up and reconfigure the bottom coil tuning jumpers to obtain the highest coil current. Note: You may have to retune the top coil again. If adjustment is required, disable antenna transmission and reconfigure the jumpers one column to the left or right in the table as required. Recheck the antenna current and readjust as required. d. When the antenna is properly tuned, return the Misc. TX Settings to their previous values:
Ant A|B|C|D Polarity: Normal TX Frequency: Hopping ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 26 of 44 8200-1048-06, REV. A
*8200-1048-06*
Step Table 17. Primary pedestal tuning table Med JW7 JW10 Off Off On On Off Off On On Off Off On On Off Off On On Coarse Adjust JW12 JW13 Off Off Off Off Off Off Off Off On On On On On On On On JW8 JW11 Off Off Off Off On On On On Off Off Off Off On On On On 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Fine JW6 JW9 Off On Off On Off On Off On Off On Off On Off On Off On Notes Top jumpers Bottom jumpers Minimum capacitance Top coil default Bottom coil default Maximum capacitance Figure 17. Location of jumpers on the primary pedestal main board B C D E F G H I A J Note: Locate the jumpers at the top of the main controller board, on the primary pedestal. A B C D E Bottom coil tuning jumpers JW13 JW11 JW10 JW9 F G H I J JW8 JW7 JW6 JW12 Top coil tuning jumpers ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 27 of 44 8200-1048-06, REV. A
*8200-1048-06*
Step 5: Checking EAS performance Using a known-good tag, test the performance of the system to ensure it performs satisfactorily. If the performance is satisfactory, you do not have to tune the antennas. If the performance is not satisfactory, you must retune the antennas. See Step 4: Tuning the Ultra 1.5 meter ABS Pedestal System, on page 22. Step 6: Adjusting the audio alarm To adjust the audio alarm from the piezo on the primary pedestal, complete the following step:
Adjust the potentiometer using a Philips screw driver. For the location of the potentiometer see Figure 18. Note: The alarm board is located under the lens cap of the primary pedestal. Figure 18. Locating the potentiometer A A Potentiometer B B Piezo Step 7: Installing the pedestal covers To install the base covers on the Ultra 1.5m ABS Pedestals, complete the following procedure. WARNING: Risk of electric shock Disconnect power from the pedestals before you proceed. Components on the circuit board have line voltage. 1. Disconnect power from the pedestals. 2. Locate the pedestal covers, you previously set aside. 3. Align the pedestal cover to the pedestal, and reattach the cover by snapping it into place. 4. At the top of the pedestal, insert the two captive screws, and then tighten the screws to secure the pedestal cover. 5. Supply power to the pedestals. 6. Test the system with an active EAS tag or label to verify that the pedestal is operational. ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 28 of 44 8200-1048-06, REV. A
*8200-1048-06*
Step 8: Covering the antenna cables If the cables were laid in a trench between the pedestals, cover them with a proper fill, such as non-metallic, non-shrink, 5000-psi mortar or concrete. The 4-meter transceiver cable assemblies, 0352-0792-01, use the cable part number 0652-0789-01. The 12-meter transceiver cable assemblies, 0352-0793-01, use the cable part number 0652-0789-02. The 15-meter transceiver cable assemblies 0352-0794-01, use the cable part number 0652-0789-03. The following cable has been investigated and found suitable for direct burial in mortar and concrete. An inspector can request the listing file number for the cable. Sensormatic part number 6002-0254-01 Rated CL2P Listing file numbers*
E34972 Vendor Belden
* The listing file number varies with the cable vendor and is printed on the cable. Step 9: Applying anti-theft labels in other languages To apply an anti-theft label in another language to the Ultra 1.5 meter ABS Pedestal System, complete the following step:
Apply the anti-theft labels in the local language over the English labels on each side of the antenna. Order local language labels, 2412-0170-XX, from your distribution center. Do not cover the Anti-theft System label. Step 10: Cleaning the pedestal WARNING: Risk of electric shock Ensure that the pedestal is powered off before cleaning. CAUTION: Avoid dripping liquids on the pedestal base. Before cleaning the pedestal, ensure that the pedestal power is off. To power off and clean the pedestal, complete the following steps:
1. Turn off the circuit breaker that provides power to the pedestal. 2. Clean the pedestal using a soft, lint-free cloth, moistened with a non-corrosive cleaning product. 3. Turn on the circuit breaker that provides power to the pedestal. 4. Test the system with an active EAS tag or label, to verify that the pedestal is operational. ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 29 of 44 8200-1048-06, REV. A
*8200-1048-06*
Field replaceable units A complete parts list is available online at https://sensormaticsecurelogin.com. Login, and on the Tech Support page, select Part Information. Part number 0500-9887-01 0312-3112-05 0312-1617-01 0312-7266-01 0404-0566-01 Description Lens cover AMS-1146 Main Board Alarm board APS 1002 AMS-1146 Secondary Board Covers Boot Loader Mode If the firmware in the main controller board is corrupt, you can override the normal boot sequence to prevent the controller board from using the firmware. Instead, the controller board will stop during the boot process and wait for new firmware to be downloaded. Important: Only use the boot loader procedure if you can not successfully download firmware to the controller board. To update the firmware on the main controller board, complete the following procedure:
WARNING: Risk of electric shock High-voltage AC is present on the Cap board whenever the controller is on. Ensure the pedestal is powered off before installing the jumper on the capacitor board. 1. Turn off power to the pedestal. 2. On the main controller board, jumper pins 1 and 2 on P18. For the location of P18, see Appendix F: Main board pinouts on page 44. 3. Connect the service laptop to the system and launch the CE ADS4 Platform Configurator. 4. Apply power to the system. The following message displays:
Boot utility is running. A Flash Download is needed. Please select a file to download. 5. Click OK. 6. On the Setup page, select Flash Download. See Figure 19. 7. Click Browse and select the flash application firmware version 1.0014 for the controller board. CAUTION: Do not interrupt the flash process. 8. Click the Start Flash Download button. For the location of the button, see Figure 19. 9. Once the download is complete, remove the jumper on P18, and reboot the system by clicking the Reset Pack button. See Figure 19. ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 30 of 44 8200-1048-06, REV. A
*8200-1048-06*
Figure 19. Flash Downloads screen A B C A B Start Flash Download button Reset Pack button Browse button C ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 31 of 44 8200-1048-06, REV. A
*8200-1048-06*
Specifications Electrical Power Supply (Primary pedestal) Primary input ........................................................................................................................ 100-120/200-240Vac @ 50-60Hz
..................................................................................................................................................................................... 1.4/0.8A Primary power fuse ..................................................................................................... 2.5A, 250V, 5x20, slo-blow, hi-breaking Current draw (120V) .................................................................................................................................................. <1.2Arms Current draw (240V) ................................................................................................................................................ <0.66Arms Input power maximum (120V) ........................................................................................................................................ <100W Input power maximum (240V) ........................................................................................................................................ <100W Transmitter Outputs .................................................................................................................................................... 2 channel transmitter Operating frequency ....................................................................................................................................... 58kHz (200Hz) Transmit burst duration ................................................................................................................................................... 1.6ms Transmit current maximum (nominal) ........................................................................................................................ 40A peak Burst Repetition Rate:
Based on 50Hz ac ...................................................................................................................................... 37.5Hz or 75Hz Based on 60Hz ac ......................................................................................................................................... 45Hz or 90Hz Transmit coil resistance ................................................................................................................................. 0.11 ohms (2%) Receiver Inputs ............................................................................................................................................................................. 8 ports Center frequency ............................................................................................................................................................ 58kHz Receive coil resistance .................................................................................................................................. 0.11 ohms (2%) Alarm Alarm Relay Output .......................................................................................................................................... DPDT contacts Contact switching current ......................................................................................................................................... 1.0A max. Contact switching voltage .......................................................................................................................................... 28V max. Lamp/Audio duration .................................................................................................................................................. 130 sec. ................................................................................................................................................................... (1 sec. increments) Audio Level .................................................................................................................................................................. 80dB(A) Environmental Operating temperature .................................................................................................................. 0C to 50C (32F to 122F) Relative humidity .............................................................................................................................. 0 to 90% non-condensing Enclosure rating ................................................................................................................................................................ IPX0 Evaluated for altitudes less than 3200m (10500ft) Mechanical Ultra 1.5 meter ABS Pedestal System Height .......................................................................................................................................................... 134.5 cm (52.9 in) Width ................................................................................................................................................................ 35 cm (13.8 in) Depth (at base w/o cover) ................................................................................................................................ 11.9 cm (4.7 in) Primary pedestal weight (with cover) ................................................................................................................. 10.4 kg (23 lb) Secondary pedestal weight (with cover) ........................................................................................................... 8.7 kg (19.2 lb) Primary pedestal weight (without cover) ........................................................................................................... 7.3 kg (16.1 lb) Secondary pedestal weight (without cover) ...................................................................................................... 5.7 kg (12.5 lb) ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 32 of 44 8200-1048-06, REV. A
*8200-1048-06*
Declarations Regulatory Information Regulatory Model: LFAMS1801 MODEL: AMS-1146 FCC ID: BVCAMSUSUPB IC ID: 3506A-AMSUSUPB This device complies with part 15 of the FCC Rules and Industry Canadas RSS-310. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. EMC: ............................................................................................................................................................... 47 CFR, Part 15
............................................................................................................................................................................... EN 300 330
............................................................................................................................................................................ EN 301 489-1
............................................................................................................................................................................ EN 301 489-3
............................................................................................................................................................................ EN 61000-3-2
............................................................................................................................................................................ EN 61000-3-3
................................................................................................................................................................................... ICES-003
.................................................................................................................................................................................... RSS-210 Safety ............................................................................................................................................................... UL/EN 60950-1
.................................................................................................................................................................. CSA-C22.2.60950-1 EQUIPMENT MODIFICATION CAUTION: Equipment changes or modifications not expressly approved by Sensormatic Electronics, LLC, the party responsible for FCC compliance, could void the user's authority to operate the equipment and could create a hazardous condition. See About the Ultra 1.5 meter ABS Pedestal System on page 3. Other declarations WARRANTY DISCLAIMER: Sensormatic Electronics, LLC makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Further, Sensormatic Electronics, LLC reserves the right to revise this publication and make changes from time to time in the content hereof without obligation of Sensormatic Electronics, LLC to notify any person of such revision or changes. LIMITED RIGHTS NOTICE: For units of the Department of Defense, all documentation and manuals were developed at private expense and no part of it was developed using Government Funds. The restrictions governing the use and disclosure of technical data marked with this legend are set forth in the definition of limited rights in paragraph (a) (15) of the clause of DFARS 252.227.7013. Unpublished - rights reserved under the Copyright Laws of the United States. TRADEMARK NOTICE: Sensormatic is a registered trademark of Sensormatic Electronics, LLC. Wiremold is a registered trademark of the Wiremold Company. Other product names mentioned herein may be trademarks or registered trademarks of Sensormatic or other companies. No part of this guide may be reproduced in any form without written permission from Sensormatic Electronics, LLC. ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 33 of 44 8200-1048-06, REV. A
*8200-1048-06*
Appendix A: Dimensions Figure 20. Ultra 1.5m Pedestal System dimensions 11.9 cm [4.7 in]
134.5 cm [52.9 in]
Figure 21. Pedestal footprint, top view 35 cm [13.8 in]
13.9 cm [5.5 in]
12.7 cm [5 in]
9 cm [3.54 in]
A B 13.9 cm [5.5 in]
A B Front cover Base 23.8 cm [9.4 in]
C D Mounting bolt center Rear cover C D ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 34 of 44 8200-1048-06, REV. A
*8200-1048-06*
Appendix B: Connecting an Auxiliary Receiver The following section describes how to connect auxiliary receivers to the Ultra 1.5 meter ABS Pedestal System. Auxiliary receivers are receive-only antennas that extend the detection range of a primary antenna. You connect the auxiliary receivers at ports P6 and P7 on the main controller board of the primary pedestal. Note: To enable an auxiliary receiver, select a configuration that uses auxiliary receiver inputs. To connect an auxiliary receiver to the Ultra 1.5 meter ABS Pedestal System, complete the following procedure:
WARNING: Risk of electric shock High-voltage AC is present on the cap board whenever the pedestal power is on. Ensure that the system is not powered before you connect the auxiliary receivers. CAUTION: Auxiliary Receiver antennas are receive-only. A transmitter current will damage them. Do not connect the auxiliary receivers to the secondary connector at P4. 1. Disconnect power from the system. 2. Connect the cable from the auxiliary receiver to the connector, P6 or P7, on the main controller board of the primary pedestal, as shown in Table 18. See Figure 22 and Appendix F: Main board pinouts on page 44. Table 18. Connecting auxiliary receivers Pin 1 2 3 4 5 Rangers Black Red Green White Shield Satellite Black Red Black Red Shield Figure 22. P6 and P7 on the main controller board Amorphous Black Red Green White Shield P7 Pin 1 P6 Pin 1 3. Supply power to the system. 4. Test the system with an active EAS tag or label to verify that the pedestal is operational. ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 35 of 44 8200-1048-06, REV. A
*8200-1048-06*
Appendix C: Connecting an UltraLink The following section describes how to connect an UltraLink to the Ultra 1.5 meter ABS Pedestal System. You can connect an RS-485 network device such as an UltraLink to the Ultra 1.5 meter ABS Pedestal System at P24 on the main controller board, using pins 1, 2, and 8. Figure 23. Connecting the system to an UltraLink Main controller board on primary pedestal P24 AC to 12Vdc Transformer Comm Cable 6003-0210-01/02 UltraLink I/O Board Grounding Post J6 Comm 1 Comm 2 CBC-4020UltraLink ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 36 of 44 8200-1048-06, REV. A
*8200-1048-06*
To connect an UltraLink to the Ultra 1.5 meter ABS Pedestal System, complete the following procedure:
WARNING: Risk of electric shock High-voltage AC is present on the cap board whenever the pedestal power is on. Ensure that the pedestal system and the UltraLink are not powered before you connect the UltraLink to the system. 1. Disconnect power from the UltraLink and the Ultra 1.5 meter ABS Pedestal System. 2. Attach the 8-position RS-485 network connector to the comm cable, as shown in Table 19. Plug the cable into the connector, P24, on the main controller board on the primary pedestal. See Figure 23, on page 36. Table 19. Connecting the Comms cable Color Pin 1 Red Black 2 8 Shield Signal RS485 Hi RS485 Lo Shield 3. Attach the comm cable to the Comm 1 connector on the UltraLink I/O board. The connections on the I/O board are determined by the revision level of the UltraLink you are installing. For UltraLink versions -01 or -02, attach the comm cable to the Comm 1 connector as shown in Table 20. For the location of the Comm 1 connector, see Figure 23, on page 36. Table 20. UltraLink version -01 or -02 connections Pin 1 2 3 Color Red Black Shield Signal RS485 Hi RS485 Lo Shield For UltraLink versions -03, -05, or-06, attach the comm cable to the Comm 1 connector, as shown in Table 21. For the location of the Comm 1 connector, see Figure 23, on page 36. Table 21. UltraLink version -03, -05, or -06 connections Pin 1 2 3 Color Black Red Shield Signal RS485 Hi RS485 Lo Shield Note: For more information on how to connect the cable, see the CBC-4020 UltraLink Indoor Installation and Service Guide, 8200-0172-01, or other appropriate device manual. 4. Supply power to the pedestals and the UltraLink. 5. Test the system with an active EAS tag or label to verify that the pedestal is operational. ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 37 of 44 8200-1048-06, REV. A
*8200-1048-06*
Configuring an UltraLink The following section describes how to configure an Ultra 1.5 meter ABS Pedestal System. Important: For correct operation, you require UltraLink Configurator Software, version 9.2.2.0 when you are installing the Ultra 1.5 meter ABS Pedestal System to an UltraLink. To configure an UltraLink to the Ultra 1.5 meter ABS Pedestal System, complete the following procedure:
1. Launch the UltraLink configurator and from the EAS SYSTEMS window, set the System Type parameter to Digital RS-485. Note: If you are connecting two Ultra 1.5m ABS Pedestals Systems, you also set EAS System 2 to Digital RS-485. By default, one is address 1 and the other is address 2. Both systems connect in parallel to the Comm1 port on the UltraLink. 2. Upload the .ini configuration file to the UltraLink configurator. Note: You must upload the configuration file to the UltraLink for changes to take effect. 3. Configure the S1 switches on the UltraLink Single Board Computer (SBC) to select RS-485. The correct switch settings are printed on the Comm Mode label that is attached to the inside of the UltraLink back cover. 4. Connect your service laptop to the system and launch the CE ADS4 Platform Configurator. 5. From the Configure menu, select Change Network Address. 6. On the Enter Devices Network Address window, in the Pack Address field, enter the number 1. Note: The primary pedestal uses address 1. 7. Click OK. Note: You require the pack address for communication between the Ultra 1.5 meter ABS Pedestal System and the UltraLink. ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 38 of 44 8200-1048-06, REV. A
*8200-1048-06*
Appendix D: Connecting a Local Device Manager The following section describes how to connect a Local Device Manager (LDM) to the Ultra 1.5 meter ABS Pedestal System. WARNING: Risk of electric shock High-voltage AC is present on the cap board whenever the pedestal power is on. Ensure that the pedestal system and the Local Device Manager are not powered before you connect the Local Device Manager to the system. To connect the Ultra 1.5 meter ABS Pedestal System to a LDM, complete the following procedure:
1. Disconnect power from the Local Device Manager and the Ultra 1.5 meter ABS Pedestal System. 2. Attach the 8-position RS-485 Network connector to the Cat5 cable, as shown in Table 22. Plug the cable into the connector, P24, on the main controller board of the primary pedestal. For the location of P24 on the main controller board, see Appendix F: Main board pinouts on page 44. Table 22. Cat5 cable connections Pin 1 2 3 4 5 6 7 8 Wire Color White/ Orange Orange White / Green Blue White / Blue Green White / Brown Brown Signal RS-485 Hi RS-485 Lo Not used Not used Not used Not used Not Used Ground 3. Attach the RJ-45 plug to the Cat5 cable, as shown in Figure 24. Plug the cable into port 1-4 on the LDM. See Figure 25 on page 40. Figure 24. Cat5 cable connections Pin 1 Pin 8 Pin 1 A A RJ-45 plug Note: Clip is pointing away from you Orange Pin Color 1 White / Orange 2 3 White / Green 4 5 White / Blue 6 7 White / Brown 8 Brown Green Blue ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 39 of 44 8200-1048-06, REV. A
*8200-1048-06*
Figure 25. LDM II Ports 1-4 A A Ports 1-4 4. Supply power to the pedestals and the UltraLink. 5. Test the system with an active EAS tag or label to verify that the pedestal is operational. Configuring a Local Device Manager The following section describes how to configure a Local Device Manger to the Ultra 1.5 meter ABS Pedestal System. Note: For correct operation, you require LDM Configurator Software, version 9.2.2.0 when you are installing the Ultra 1.5 meter ABS Pedestal System to a Local Device Manager. To configure a LDM to the Ultra 1.5 meter ABS Pedestal System, complete the following procedure:
1. Connect your laptop to the RS-232 service port, J2, on the primary controller board. For the location of J2, see Appendix F: Main board pinouts on page 44. 2. Launch the CE ADS4 Platform Configurator. 3. From the Configuration menu, select Change Network Address. 4. On the Enter Devices Network Address window, in the Pack Address field, set the device address in the range of 1 to 253. 5. Click OK. Note: You must enter a unique address from other addresses on the network. For more information on connecting the Ultra 1.5 meter ABS Pedestal System to a Local Device Manger, see the CBC-4055 Local Device Manager II Installation Guide, 8200-0858-01. ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 40 of 44 8200-1048-06, REV. A
*8200-1048-06*
Appendix E: Connecting a Digital Remote Alarm The following section describes how to connect a digital remote alarm to the Ultra 1.5 meter ABS Pedestal System. The Ultra 1.5 meter ABS Pedestal System supports the use of the AMC-1060 Digital Remote Alarm (DRA). You can connect the DRA to the main controller board in two ways. You can connect to the RS-485 Peripheral Network connector at TB2, or the relay port at J1. Connecting the digital remote alarm to relay port J1 The following section describes how to connect the DRA to the relay port J1 on the main controller board of the Ultra 1.5 meter ABS Pedestal System. If you connect a DRA to the relay port, the Remote Alarm will alarm only on tag detection and will not support additional features such as tags-too-close, jammer detection, and people-count display. To connect the Digital Remote Alarm to the relay port J1 on the AMS-1146 Pedestal, complete the following procedure:
WARNING: Risk of electric shock High-voltage AC is present on the cap board whenever the pedestal power is on. Ensure that the pedestal system and the digital remote alarm are not powered before you connect the digital remote alarm to the system. 1. Disconnect power from the digital remote alarm and the Ultra 1.5 meter ABS Pedestal System. 2. Ensure that jumper P3 in the DRA is in the IN position. 3. Connect the alarm cable to the DRA and the pedestal. Note: If you are connecting the DRA to a single pedestal system, connect the alarm cable to the DRA and the main controller board of the primary pedestal, as shown in Figure 26 on page 42. For the location of J1 on the main controller board, see Appendix F: Main board pinouts on page 44. 4. Supply power to the pedestals and the digital remote alarm. 5. Test the system with an active EAS tag or label to verify that the pedestal is operational. ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 41 of 44 8200-1048-06, REV. A
*8200-1048-06*
Figure 26. Wiring the DRA to the relay port A P3 - In y a r G n e e r G k c a B l l d e h S i B d e R n e e r G Shield 1 Gray Green 6 7 C A B Digital Remote Alarm AC Adapter Note: You must use the ZP1060-T AC Adapter. Do not use the Universal Transformer C Relay port, J1, on main controller board Connecting the DRA to the Peripheral Network RS-485 Port (TB2) The following section describes how to connect the DRA to the Peripheral Network RS-485 Port, TB2, on the main controller board of the Ultra 1.5 meter ABS Pedestal System. If you connect a remote alarm to TB2, the DRA supports all types of alarms, for example, tags-too-close, jammer detection, and people-counting. To connect the Digital Remote Alarm to the Peripheral Network RS-485 Port, TB2, on the Ultra 1.5 meter Pedestal, complete the following procedure:
WARNING: Risk of electric shock High-voltage AC is present on the cap board whenever the pedestal power is on. Ensure that the pedestal system and the digital remote alarm are not powered before you connect the digital remote alarm to the system. 1. Disconnect power from the digital remote alarm and the Ultra 1.5 meter ABS Pedestal System. 2. Ensure that the jumper P3 in the DRA is in the OUT position, and the rotary switch is set to address 0. 3. Locate the connector, 0304-2930-01, in the DRA installation kit and attach the connector to the DRA, as shown in Figure 27 on page 43. ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 42 of 44 8200-1048-06, REV. A
*8200-1048-06*
4. At the main controller board of the primary pedestal, connect the cable to the Peripheral Network terminal block, TB2. For the location of the Peripheral Network terminal block, see Appendix F: Main board pinouts on page 44. Note: You can also connect the DRA at pins 4, 5 and 6 on the TB2 terminal block. 5. Supply power to the pedestals and the digital remote alarm. 6. Test the system with an active EAS tag or label to verify that the pedestal is operational. Figure 27. Wiring the DRA to the RS-485 port A P3 - Out d e R l d e h S i k c a B l k c a B l e g n a r O t l e o V i B d e R n e e r G 1 2 3 C A B Digital Remote Alarm AC Adapter Note: You must use the ZP1060-T AC Adapter. Do not use the Universal Transformer C Peripheral Port, TB2, on the main controller board ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 43 of 44 8200-1048-06, REV. A
*8200-1048-06*
Appendix F: Main board pinouts Top coil Bottom coil Aux Rec 2 P3 P1 P7 Aux Rec 1 P6 Peripheral Network TB2 RS-485 Network*
P24 Wired sync P8 Relay J1 Alarm board P5 Service J2 Flash Override**
P18 Signal Top coil return Shield Top coil Signal Top coil return Shield Top coil Signal Ground Antenna D2 return Antenna D2 Antenna D1 return Antenna D1 Signal Ground Antenna C2 return Antenna C2 Antenna C1 return Antenna C1 Signal RS-485 low*
RS-485 high*
Ground RS-485 low*
RS-485 high*
Ground Signal Ground Ground Sync low (B) Not used Not used Sync high (A) RS-485 Low*
RS-485 high*
Signal Ground Wired sync arm low Wired sync arm high RS-485 low*
RS-485 high*
Signal Ground Not used NO 2 ARM 2 (COM 2) NC 2 NO 1 ARM 1 (COM 1) NC 1 Signal Power LED-
Alarm CLK-
Audio
+12V
+5V Ground Tx Inhibit Ground Signal RS-232 RX RS-232 TX Ground Not used Pins 1 2 3 Pins 1 2 3 Pins 5 4 3 2 1 Pins 5 4 3 2 1 Pins 1 2 3 4 5 6 Pins 8 7 6 5 4 3 2 1 Pins 5 4 3 2 1 Pins 1 2 3 4 5 6 7 8 Pins 1 2 3 4 5 6 7 8 Pins 1 2 3 4 Pins 1 2 A B C D E F G H I J K A B I J K C D E F G H
* Connect RS-485 options by connecting the RS 485 LO wire to the RS 485 LO pin and the RS 485 HI wire to the RS 485 HI pin.
**To override the normal boot process, short pins 1 and 2 of connector P18. ULTRA 1.5 METER ABS PEDESTAL SYSTEM INSTALLATION GUIDE 44 of 44 8200-1048-06, REV. A
*8200-1048-06*
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2018-05-30 | 0.058 ~ 0.058 | FAP - Part 15 Anti-Pilferage Device | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2018-05-30
|
||||
1 | Applicant's complete, legal business name |
Tyco Safety Products/Sensormatic
|
||||
1 | FCC Registration Number (FRN) |
0005052626
|
||||
1 | Physical Address |
6600 Congress Ave
|
||||
1 |
Boca Raton, Florida 33487
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
t******@siemic.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
BVC
|
||||
1 | Equipment Product Code |
AMSUSUPB
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
W**** D******** O******
|
||||
1 | Title |
Principal Compliance Engineer
|
||||
1 | Telephone Number |
561-9********
|
||||
1 | Fax Number |
561-9********
|
||||
1 |
b******@tycoint.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 11/26/2018 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | FAP - Part 15 Anti-Pilferage Device | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | ANTI-PILFERAGE DEVICE | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Limited Single Modular Approval | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Limited Single Modular Approval of this Transmitting device with antenna(s) as shown in this filing is allowed for Grantees products for integration into their host products. OEM integration of this device into a host product is not allowed per this application. Third-party Class II applications cannot be used for integrating this device with different host products and/or antenna(s). Alternatively, a separate FCC equipment authorization for new antenna(s) or host devices may be obtained; otherwise, any new host devices will be considered unauthorized equipment. Compliance of this device in any final configuration is the responsibility of the Grantee. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Bureau Veritas Consumer Products Services, Inc.
|
||||
1 | Name |
L**** B********
|
||||
1 | Telephone Number |
408-5********
|
||||
1 | Fax Number |
408 5********
|
||||
1 |
l******@siemic.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 0.05800000 | 0.05800000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC