AMS-9080 Controller Installation Guide Do Not Discard!
Document may be needed by code inspectors. Leave it at the site until the installation is complete and the system has been approved. ZE9080 2018 Sensormatic Electronics, LLC AMS-9080 CONTROLLER INSTALLATION GUIDE 1 of 22
*8200-0914-01*
8200-0914-01 REV. A Table of contents About this guide ..........................................................................................................................................3 About the product ........................................................................................................................................3 Installation features ..............................................................................................................................3 Parts ..........................................................................................................................................................4 Compatibility .............................................................................................................................................4 Safety ........................................................................................................................................................4 Before you begin .........................................................................................................................................7 Installation ....................................................................................................................................................8 Mounting the controller .............................................................................................................................8 Connecting the AC power .........................................................................................................................9 Connecting to the pedestals .................................................................................................................. 12 Connecting to auxiliary receiver antennas ............................................................................................. 13 Connecting optional devices .................................................................................................................. 14 Configuring the system .......................................................................................................................... 15 Troubleshooting ....................................................................................................................................... 16 Servicing the AMS-9080 Controller ......................................................................................................... 18 Replacing the fuse ............................................................................................................................ 18 Boot Loader mode ............................................................................................................................ 18 Specifications ........................................................................................................................................... 19 Declarations .............................................................................................................................................. 20 AMS-9080 Controller dimensions ........................................................................................................... 21 AMS-9080 Controller board pinouts ....................................................................................................... 22 AMS-9080 CONTROLLER INSTALLATION GUIDE 2 of 22
*8200-0914-01*
8200-0914-01 REV. A About this guide This installation guide explains how to install the AMS-9080 Controller. You must install the AMS-9080 Controller, as outlined in this guide. Customer requirements dictate the placement of system components. Your Sensormatic representative supplies this information separately. Regulatory restriction: For indoor use only. Intended use: Install this device only as described in this guide. If you install this product in a European Union or European Free Trade Association member state, give the Declaration of Conformity included with this product to the manager or user. By law, you must provide this information to the user. Technical support For product bulletins, and the most recent updates to this document, visit https://sensormaticsecurelogin.com. About the product The AMS-9080 Controller powers and operates the capacitor board, and the antenna coils on a pedestal. Installation features The AMS-9080 Controller has the following installation features:
Antenna support The AMS-9080 Controller supports up to two transceiver exit pedestals, each with two coils, top and bottom. Each coil is a transceiver, which receives and transmits. You can set up the antennas using a laptop computer and the CE ADS4 Platform Configurator. You can set the antenna coils for phase flipping, which is the default operation, aiding, or figure-8 operation. Note: Phase flipping is unavailable when you use noise cancelling antenna coils. Alarm support The AMS-9080 Controller supports the following alarm devices:
A built-in alarm in the antenna Two externally-powered remote alarms, such as an AMS-1060 digital remote alarm Up to two relays for devices, such as security cameras Externally-powered Sensormatic alarm management or traffic flow devices Wired synchronization Use wired synchronization to connect two AMS-9080 Controllers, and to prevent them from interfering with one another. For more information, refer to the Wired Sync Hookup Installation Guide, 8200-0537-07. For the location of the wire sync connector P8, see AMS-9080 Controller board pinouts. Manual voltage selection At installation, you must manually select one of the following controller voltage ranges:
100 VAC to 120 VAC 220 VAC to 240 VAC AMS-9080 CONTROLLER INSTALLATION GUIDE 3 of 22
*8200-0914-01*
8200-0914-01 REV. A Conduit support Seven knockouts receive exposed cables or cables in conduit. Knockouts are available for Class-2 wiring from antennas and low voltage devices. Parts Table 1. Required parts Kit AMS-9080 Controller Installation Kit Table 2. Installation Kit, 0352-0286-02 Part Clamp, conduit Compatibility Quantity Product code 1 1 ZE9080 0352-0286-02 Quantity Product code 10 6010-0107-01 The AMS-9080 Controller is compatible with the following products:
AMS-1156 Pedestal Ranger antennas Satellite antennas Amorphous core receivers Digital Remote Alarm (DRA) Ultra-Link Local Device Manager (LDM) Wireless Device Manager (BIM1000) and the Wireless Device Module (BIX1000) Overhead people counters Safety Installation requirements Intended use: Install this device only as described in this guide. The installer or contractor must adhere to the following criteria:
Ensure that electrical work complies with the latest national electrical code, national fire code, and all applicable local codes and ordinances. National or local wiring codes or rules can differ between regions. Adherence to these codes supersedes instructions in this document. You must coordinate all work with other trades to avoid interference. You must verify existing site conditions, and coordinate with the owners representative and appropriate utilities, as required. You must obtain copies of all related plans, specifications, shop drawings, and addenda to schedule and coordinate related work. You must thoroughly review the project to ensure that all work meets or exceeds the above requirements. The installer or contractor must bring any alleged discrepancies to the attention of Sensormatic Electronics. AMS-9080 CONTROLLER INSTALLATION GUIDE 4 of 22
*8200-0914-01*
8200-0914-01 REV. A Chemical interaction WARNING: Do not install this product in hazardous areas where highly combustible or explosive products are stored or used. Cabling WARNING: Risk of electric shock. During installation, if you must leave the antenna, turn off the power or cover high voltage components to prevent unauthorized access to hazardous voltages. WARNING: Risk of electric shock. The AC power could be carrying 120 VAC or 240 VAC. WARNING: Risk of electric shock. The transmit pedestal contains hazardous voltages. If you must leave the pedestal with its high voltage components exposed, turn off the power or cover these components to avoid unauthorized persons access to hazardous voltages. WARNING: In accordance with the USA National Electric Code and applicable US local codes, a 15 A or 20 A, two-pole, ganged disconnect device, which also provides short circuit and overload protection and has a minimum 3-millimeter open circuit clearance, must be installed by a licensed electrician at a location readily accessible to the equipment. For installations in other countries, an electrical outlet, suitable for the voltage and current used in the primary electrical supply input of the equipment, must be already provided or installed by a qualified electrician. The National Electric Codes, regulations, cable, and fusing requirements applicable for the equipment and type of installation must be followed at all times. WARNING: This device is not suitable for an IT power distribution system where impedance exists between neutral and protective earth contacts. CAUTION: To meet EMC regulatory compliance, you cannot cut the interconnect transceiver cable when using the AMS-9080 Controller. You can coil any excess cable and secure it with a cable tie. CAUTION: The AC source must be a two-wire plus ground, 24-hour, unswitched outlet with less than 0.5 VAC between neutral and ground. CAUTION: Install pluggable equipment in a position where it is near the socket-outlet, and easy to access. CAUTION: For continued protection against risk of fire, replace the fuse only with the same fuse type and rating. Important:
Follow all local, state, and federal electrical and fire codes for cabling into the AMS-9080 Controller. Do not share the AC source with neon signs, motors, computers, cash registers, terminals, or data communications equipment. Do not use orange-colored outlets which are dedicated for computer equipment. AMS-9080 CONTROLLER INSTALLATION GUIDE 5 of 22
*8200-0914-01*
8200-0914-01 REV. A Mounting CAUTION: The controller can attach to a wall or ceiling using suitable hardware. The structure and hardware must support 9.56 kilograms or 21.08 pounds, or four times the weight of the controller assembly. Implanted medical devices This anti-theft system complies with all applicable safety standards. People with implanted electronic medical devices can ask if the store has an anti-theft system, and its location. You can easily see most anti-theft systems, but some can be concealed. To help individuals with implanted medical devices, consider the following health and safety guidelines:
Health and safety Place the anti-theft system antennas to ensure that customers behave in the following ways:
They do not linger near, or lean on anti-theft systems while making their purchase. They are near the front of an anti-theft system only while exiting the checkout area. For exit systems, when placing anti-theft system antennas, adhere to the following guidelines:
Place the anti-theft system antennas close to exit and entrance doors, encouraging the customer to pass through them. Do not use antennas intended for exits in an aisle configuration. Place the anti-theft system antennas away from fixtures, equipment, amusements, and other signage that can attract customers to them. Apply Anti-theft signage Place Anti-theft labels on each antenna, including those hidden behind door frames and other structures. Do not cover these labels with other signage. In non-English speaking countries, apply Anti-theft labels in the local language to the antennas. For hidden antennas, apply an Anti-theft label in the local language to each side of the door frame facing the doorway, about 1.2 meters or 4 feet above the floor. You can order local language labels, 2412-
0170-XX, from your distribution center. To improve customer awareness of the anti-theft system, encourage the store to display signs that state that it has an anti-theft system. You can order awareness materials through your sales representative. AMS-9080 CONTROLLER INSTALLATION GUIDE 6 of 22
*8200-0914-01*
8200-0914-01 REV. A Before you begin Before you install an AMS-9080 Controller, adhere to the following criteria. Unpacking and verifying the equipment When unpacking and verifying the equipment, complete the following checks:
Verify that you have all the necessary equipment. Ensure that the system configuration is the correct one for the site. Unpack major components in a space where you are not obstructing, or causing nuisance to customers. Do not clutter the aisle or cause a trip hazard. Tool requirements You require the following tools:
A tape measure A pencil or a marker An electric drill A Phillips-head screwdriver or bit A hand vacuum or broom Equipment requirements You require the following equipment:
An AMS-9080 Controller, ZE9080 Pedestal antennas, for example, the AMS-1156 Pedestal A hard non-deactivatable AM tag, or AM low energy labels Installation kit, 0352-0286-02 Laptop requirements You require the following items:
A laptop computer with Windows 7 operating system and the latest Internet Explorer, or Mozilla Firefox browser installed. A USB to RS-232 converter, if required An RS-232 UltraMax programming cable Firmware requirements Table 3. Required firmware Compatible firmware CE ADS4 Platform Configurator AMS-9080 Controller firmware Version 9.20, build 26 or higher 1.1011 or higher To support the installation of the AMS-9080 Controller, you must download the latest firmware bundle from https://sensormaticsecurelogin.com/. To download the latest configurator, complete the following steps:
1. Open a web browser, and navigate to https://sensormaticsecurelogin.com/. 2. Enter your valid logon details, and click Login. 3. From the Tech Support menu, click EAS. 4. Click Software Download. 5. From the Technology list, select Detectors. 6. Download the latest bundle. AMS-9080 CONTROLLER INSTALLATION GUIDE 7 of 22
*8200-0914-01*
8200-0914-01 REV. A Installation To install an AMS-9080 Controller, complete the following procedures. Mounting the controller You can mount the AMS-9080 Controller to the following locations:
On a shelf On a wall To a ceiling Note: For ceiling mounts, secure plywood with a surface larger than the controller to the ceiling studs that hold the drywall. Attach the controller with suitable hardware for the plywood. To mount the controller, complete the following steps:
CAUTION: To facilitate the detachment of controller electronics, you must keep 22.9 centimetres or 9 inches of free space to the right of the controller for screwdriver access. 1. Remove the top cover from the controller. 2. Remove the knockouts closest to the connectors that you are going to use. 3. Set the controller on a shelf, or use suitable anchors and hardware to mount it to a wall or ceiling. Note: If only ceiling studs are located above the ceiling, you must attach plywood to the ceiling. Then attach the controller to the plywood with suitable hardware. WARNING: Both the anchor system and the wall or ceiling must be able to support 9.56 kilograms or 21.08 pounds, or four times the weight of the controller assembly. 4. Run the cables from the antennas and devices through the appropriate knockouts, and secure them using the cable clamps provided. Figure 1. Locating the mounting holes A AMS-9080 Controller B Mounting holes AMS-9080 CONTROLLER INSTALLATION GUIDE 8 of 22
*8200-0914-01*
8200-0914-01 REV. A Connecting the AC power To connect the AC power to the AMS-9080 Controller, complete the following steps:
WARNING: In accordance with the USA National Electric Code and applicable US local codes, a 15 A or 20 A, two-pole, ganged disconnect device, which also provides short circuit and overload protection and has a minimum 3-millimeter open circuit clearance, must be installed by a licensed electrician at a location readily accessible to the equipment. If the only line providing power is the primary/L1, you can use a single-pole breaker. 1. Locate the voltage shunt in a bag taped inside the controller. WARNING: Risk of electric shock. Ensure that you disconnect power from the controller before you move the shunts. 2. Select the proper voltage for the site using the shunt, 2109-0062-01. The default setting is 240 VAC. 3. The AMS-9080 Controller can receive AC power through a power cord, or through a hardwired connection. Complete one of the following procedures:
Connecting the power cord Hardwiring the AC connection Figure 2. Voltage settings and shunts A B 120 VAC, J5 shunt IN 240 VAC, J5 shunt OUT Connecting the power cord In countries where code allows, you can connect the AC power using a power cord. To connect the AC power using a power cord complete the following steps:
1. From Table 4, choose a power cord for the country of use. Table 4. Power cord part numbers per country Power cord USA-IEC 320, 18/3, 125 V, 10 A, 7.5 ft Schuko-IEC 320, 1 mm2, 250 V, 10 A, 2.5 m UK-IEC 320, 1 mm2, 250 V, 10 A, 2.5 m Japan-IEC 320, 2 mm2, 250 V, 15 A, 2.5 m US-Filter, Line, 125 V, 6 A, Plug-in Australia to IEC 320, 2.5 m, 250 V, 10 A Part number 0351-0547-01 0351-0547-02 0351-0547-03 0351-0547-04 0351-0547-05 0351-0547-07 AMS-9080 CONTROLLER INSTALLATION GUIDE 9 of 22
*8200-0914-01*
8200-0914-01 REV. A WARNING: Risk of electric shock. The AC power cord can carry 120 VAC or 240 VAC. CAUTION: When using a power cord, ensure that you install the controller near a socket-outlet and in a location that is easy to access. 2. Plug the power cord into the IEC320 receptacle on the AMS-9080 Controller, and into the power source. Figure 3. Locating the power cord connector A AMS-9080 Controller B AC IN, 120 VAC or 240 VAC Hardwiring the AC connection To hardwire a controller, you must remove the AC wiring and move the ferrite bead to the new cables. To hardwire the AC connection, complete the following steps:
CAUTION: Use only copper wire. WARNING: Risk of electric shock. The AC power cord can carry 120 VAC or 240 VAC. Ensure that you turn off the power at the circuit breaker before you proceed. 1. Ensure that you disconnect the power going to the controller and the hard-wire cables. 2. On the main board locate the power connector P2, loosen the screws and remove the two wires. For the location of the power connector P2, see AMS-9080 Controller board. 3. Unscrew the ground lug. 4. Cut the three wires that connect the IEC320 connector to the wiring harness with the ferrite bead, and remove the wiring. Cut the wires as close as possible to the quick disconnect plugs, as shown in Figure 4. 5. Cut the ferrite bead from the internal wiring harness. Figure 4. Cutting the wires A Location to cut the wires B Ferrite bead AMS-9080 CONTROLLER INSTALLATION GUIDE 10 of 22
*8200-0914-01*
8200-0914-01 REV. A 6. Remove one of the knockouts to access the AC connection area. Thread a cable clamp into the hole. 7. Route the AC cable through a cable clamp, leaving about 15.2 centimeters or 6 inches out the other side. 8. Tighten the clamp around the cable. 9. Put the ferrite bead on the Line, Neutral, and Ground wires. Ensure that the wires wrap around and pass through the ferrite bead a second time as it did in the existing wiring harness. 10. Connect the AC power wires to the power connector P2. Connect the Line black wire to L, and the Neutral white wire to N as shown in Figure 5. Note: The power connector accepts 0.75 to 2.0 millimeter2, or 18 to 14 AWG wire. Important: If you remove the connector, do not pull it out by the wires; pull on the connector. 11. Connect the Ground green wire to the ground screw on the main board, as shown in Figure 6. When you connect the Ground wire, ensure that the slot on the washer is pointing down so that the jacket on the cable can fit behind the washer. WARNING: After you tighten the ground screw, carefully inspect the Ground wire to ensure that no wire strands are touching any components on the board. Figure 5. Connecting the wires to the power connector P2 A C E AC power cable B Line black wire connecting to L D Ground green wire connecting to the ground screw F Power connector P2 Neutral white wire connecting to N Ferrite Figure 6. Connecting the ground wire A C Ground screw Ground wire B D Washer, slot points down towards wire jacket External earth ground cable jacket AMS-9080 CONTROLLER INSTALLATION GUIDE 11 of 22
*8200-0914-01*
8200-0914-01 REV. A Connecting to the pedestals Transceiver pedestals connect to the AMS-9080 Controller using the following cables:
A transceiver, Tx/Rx cable An alarm/comm cable Connect the cables to the following connectors:
Transceiver connectors P3, P1, and P4: Connectors P3 and P1 are labelled Pedestal 1. Connector P4 is labelled Pedestal 2. Table 5 shows the connections for various antenna configurations. If auto configuration is enabled, the system automatically attempts to configure itself based on the number of antennas it detects. Only the most commonly used configurations are auto configured. Alarm and communication connectors TB2 and P10: Two connectors provide the peripheral RS-485 communication signals to control the audio and visual alarm functions on the pedestals. To connect pedestals to the controller, complete the following steps:
WARNING: Risk of electric shock. The AC power cord can carry 120 VAC or 240 VAC. Ensure that you turn off the power at the circuit breaker before you proceed. CAUTION: To meet EMC regulatory compliance, you cannot cut the interconnect transceiver cable when using the AMS-9080 Controller. You can coil any excess cable and secure it with a cable tie. 1. Ensure that you turn off the power to the controller. 2. Connect the cables to the controller based on the configuration you require. For more information, see Table 5. 3. For information about pedestal installations, refer to the installation guide of the antenna that you are installing. Note: Split and quad configurations are not supported with this controller. Table 5. Exit systems Mode Single Transceiver 1-2 Dual 1-2 Dual Sim.- Alternating 1-2 Dual with Ferrites 1-2 Backfield 1-2 Alternating AMS-9080 CONTROLLER INSTALLATION GUIDE Pedestal 1 connections Pedestal 2 connections AUX connections RX A / Alarm A TX A TX A TX A TX A TX A
-
TX B TX B TX B TX B TX B
-
-
-
AUX
-
-
12 of 22
*8200-0914-01*
8200-0914-01 REV. A Connecting to auxiliary receiver antennas Auxiliary receivers are receive-only antennas that extend the detection range of a primary antenna. Connect the auxiliary receivers to one of the following receiver connections:
Receiver 1, P6 Receiver 2, P7 To connect an auxiliary receiver to the controller, complete the following steps:
WARNING: Risk of electric shock. High-voltage AC is present on the capacitor and controller board whenever the controller power is on. Ensure that the system is not powered before you connect the auxiliary receivers. CAUTION: Auxiliary receiver antennas are receive-only. A transmitter current can cause damage to them. Do not connect the auxiliary receivers to receiver port P4 on the AMS-9080 Controller. 1. Disconnect power from the system. 2. Connect the cable from the auxiliary receiver to receiver port P6 or P7 on the AMS-9080 Controller, as shown in Table 6 and Figure 7. 3. Supply power to the system. 4. Test the system with an active EAS tag or label, to verify that the pedestal is operational. Table 6. Connecting auxiliary receivers Pin 1 2 3 4 5 Color Black Red Green White Shield Figure 7. Connectors P6 and P7 on the AMS-9080 Controller A C AMS-980 Controller board Pin 1 B D P7 P6 AMS-9080 CONTROLLER INSTALLATION GUIDE 13 of 22
*8200-0914-01*
8200-0914-01 REV. A Noise canceling coils Noise canceling coils, such as a Ranger antenna, cancel the noise that interferes with detector operation. Noise canceling coils connect to Aux rec 1 connector P6, Pin 1 and Pin 2, or Aux rec 2 connector P7, Pin 1 and Pin 2. To accept a noise canceling coil, on the CE ADS4 Platform Configurator set the auxiliary input to Noise Canceling mode. Save the adjustments to default settings if they will be used on the next power cycle or system reset. To find where noise cancellation is best, move the noise canceling coil around while monitoring the power levels on a laptop computer. Install the coil where noise cancellation is best. Ensure that the location for the noise canceling coil is practical and yields satisfactory results. Connecting optional devices To connect optional devices, use one of the following connectors:
Relay connectors, J1: The controller has two single-pole double-throw (SPDT) relays. Configure each connector using the CE ADS4 Platform Configurator. Each relay triggers devices such as externally powered remote alarms, time-lapse VCRs, and security cameras; one device per detection zone. Each relay accepts three wires and a shield. The cable shields share one pin on the connector. Remote alarm connectors, TB2: This connector can connect two DRAs, as there are two RS485 ports on the TB2. The first RS485 port is Pin 1, Pin 2, and Pin 3. The second RS485 port is Pin 4, Pin 5, and Pin 6. Note: If the TB2 connector has alarm/comm cable wires from connected Pedestals, take the existing wires and connect them in parallel with the DRA wires. Important: The AMS-9080 Controller does not provide power for the digital remote alarms. You need a nearby power outlet to support the required AC adapter. RS-485 network connector, P24: This connector supports RS-485 communication for remote diagnostics. You also use it as the connector for UltraLink, BIM1000, and BIX1000 devices. Wired Tx sync connector, P8: Use the wired Tx sync connector to connect an AMS-9080 Controller to an AMS-9080, AMS-9060, AMS-9050, or AMS-9040 Controller, so that they synchronize and avoid cross interference. RS-232 service connection, J2: The RS-232 connector receives the cable to connect to the local laptop computer that you are using to set up and diagnose the detection system. AMS-9080 CONTROLLER INSTALLATION GUIDE 14 of 22
*8200-0914-01*
8200-0914-01 REV. A Configuring the system To change the controllers parameters, complete the following steps:
1. On a laptop computer, launch the CE ADS4 Platform Configurator. Note: For information on how to use configurator settings, refer to the CE ADS4 Platform Configurator Help Guide. IMPORTANT: Ensure that you turn off the power to the controller. Never restart or boot up a computer that connects to an active controller, as it can disable the mouse function on the computer. 2. Connect the DB-9 to RJ-11/12 connector to the DB-9 serial port on a laptop computer. Use only Pin 2, Pin 3, and Pin 5. 3. Connect the RJ-11/12 connector of the service cable to the DB-9 connector. 4. Connect the RJ-10/22 connector of the service cable to the RS-232 port, J2 on the controller. 5. Supply power to the controller. 6. On the CE ADS4 Platform Configurators Setup page, complete the following steps:
a. Ensure that the antenna selections match the antennas that are physically installed. If they do not match, check each antennas connection to the controller. b. Set up the required parameters for lamps, audio, relays, and remote alarms. 7. On the Tx Configuration page, complete the following steps:
a. Set the Tx current for each antenna. b. Enable or disable transmitters, if necessary. 8. Verify the antenna performance by passing an active security tag by each antenna. 9. Check that the antenna alarm-lamp lights when you pass a tag or label through the checkout aisle. If the system is covering adjacent aisles, check that the lamp lights only in the aisle that the tag or label passes through. 10. If the pick rate is acceptable, installation is complete. 11. Reattach the top cover to the controller. 12. If you are installing this controller in Japan, ensure that the Japanese regulatory label, 0352-0398-07, is attached to a flat surface on the controller. Figure 8. Connecting the service cable with a male RJ-10/22 phone connector and a male RJ-11/12 connector to a DB-9 to RJ-11/12 connector A C RJ-10/22 connector RJ-11/12 connector AMS-9080 CONTROLLER INSTALLATION GUIDE Service cable DB-9 to RJ-11/12 connector B D 15 of 22
*8200-0914-01*
8200-0914-01 REV. A Troubleshooting System status alert codes The system status LED on the controller displays system status alert codes. When an alert code occurs, the color and pattern of the LED changes. A red LED indicates serious alerts, and a yellow LED indicates less serious alerts. Alert codes repeat until the condition resolves or a timer resets the system. When monitoring system status alerts, take note of the following guidelines:
The number of red flashes identifies a digit in a two-digit alert code, for example, four flashes indicates the number four. A long LED interval indicates the start of an alert code. Then the first digit of a two-digit error code occurs, followed by a short delay, followed by the second digit. Most alert codes automatically resolve. For the significance of the alert codes, see Table 7. You can only access some codes using the service configurator, as they do not display on the system status LED. You cannot access alert codes when the controller is reset. Code storage has a time stamp in days, hours, minutes, seconds, milliseconds, or check marks of when the system alert occurs. Table 7. Alert codes Alert code Alert code name Action 11 12 13 14 15 16 17 18 21 22 25 26 27 39 41 42 43 44 45 49 51 52 53 54 56 57 58 Illegal instruction May need software update Unimplemented interrupt May need software update NVM write failed Invalid device Fatal error; replace the pedestal May need software update Sequence table error May need software update Out of memory Undecided: No split Watchdog: Task reset Replace the pedestal Not applicable Recoverable. Reset the NVM to its default setting. If the problem persists, reinstall the application software. If the problem still persists, replace the pedestal. Antenna A software current fault Recoverable Antenna B software current fault Recoverable Hardware current fault Recoverable Antenna A current sense fault Recoverable Antenna B current sense fault Recoverable Sequence table mismatch Recoverable Missing zero crossing Wired Sync: missing signal Recoverable. Check the AC line quality. If the AC line quality is sufficient, replace the pedestal. Recoverable. This occurs when you select Wired Sync as the Sync source on the configurator but no signal is received. Check the connection on the wired sync connector P8 on the receiver board, and the signal source. Temperature fault Software temperature fault Recoverable Recoverable PWM fault Real-time error Auto setup owner timeout Replace the pedestal Recoverable Recoverable Auto setup release without lock Recoverable Auto setup buffer overrun Auto setup Mailbox Full Notch Select Timeout Window Select Timeout Auto setup illegal owner Recoverable Recoverable Recoverable Recoverable Recoverable AMS-9080 CONTROLLER INSTALLATION GUIDE 16 of 22
*8200-0914-01*
8200-0914-01 REV. A Alert code Alert code name Detector overrun Alarm mailbox full Action Recoverable Recoverable Host communication mailbox full Recoverable. Reload the application software. If the error does not Sequencer mailbox full Recoverable eliminate, replace the pedestal. LDM power save active Not an error. The LDM sent the system into power save mode. LDM power save inactive Not an error. The LDM sent the system to exit power save mode. 61 62 63 64 65 66 Local diagnostics Use the CE ADS4 Platform Configurator to troubleshoot and change the AMS-9080 Controllers parameters. You require the following hardware:
A laptop computer. A service cable, with a male RJ-10/22 phone connector on one end and a male RJ-11/12 connector on the other. A DB-9 to RJ-11/12 connector. To connect the cables, complete the following steps:
1. Connect the DB-9 to RJ-11/12 connector to the DB-9 serial port on a laptop computer. Use only Pin 2, Pin 3, and Pin 5. 2. Connect the RJ-11/12 connector on the service cable to the DB-9 connector. 3. Connect the RJ-10/22 connector on the service cable to the RS-232 port, J2 on the controller. Remote diagnostics If you install an AMS-9080 Controller and connect it to an Ethernet network, you can configure and service the controller from a remote location. AMS-9080 CONTROLLER INSTALLATION GUIDE 17 of 22
*8200-0914-01*
8200-0914-01 REV. A Servicing the AMS-9080 Controller Replacing the fuse WARNING: Risk of electric shock. Ensure that the unit is powered off completely before checking, touching, or changing a fuse. The printed circuit board in the controller has two fuses, F1 and F2. If either of the fuses blow, replace them with a 2.5 A, 250 V, 5X20, slow-blow, high-breaking fuse. Note: The part number for this fuse is 5111-0028-08. Boot Loader mode If you are unable to establish communication with the controller board, or if an update of the firmware fails, you can place the board in Boot Loader mode. Boot Loader mode overrides the normal boot sequence to prevent the controller board from using the application firmware. Instead, the controller board stops during the boot process, and waits for new firmware to download. Important: Use the boot loader procedure only if you cannot successfully download firmware to the controller board. To enable Boot Loader mode, complete the following steps:
WARNING: Risk of electric shock. High-voltage AC is present on the capacitor board whenever the controller is powered on. Ensure that the controller is powered off before installing the jumper on the capacitor board. 1. Turn off the power to the pedestal. 2. On the controller board, jumper Pin 1 and Pin 2 on the Connector P18. For the location of Connector P18, see AMS-9080 Controller board. 3. Connect a laptop to the system and launch the CE ADS4 Platform Configurator. 4. Apply power to the system. The following message appears: Boot utility is running. A Flash Download is needed. Please select a file to download. 5. Click OK. 6. On the Setup page, click Flash Download. 7. Click Browse, and select the flash application firmware version 1.1011 or higher for the controller. CAUTION: Do not interrupt the flash process. 8. Click the Start Flash Download icon. 9. After the download is complete, remove the jumper on the Connector P18, and click the Reset Pack icon to reboot the system. AMS-9080 CONTROLLER INSTALLATION GUIDE 18 of 22
*8200-0914-01*
8200-0914-01 REV. A Specifications Electrical Power Supply Primary input ............................................................................................................................................... 100 to 120 VAC or 220 to 240 VAC @ 50 to 60 Hz Primary power fuse ............................................................................................................................ 2.5 A, 250 V, slow-blow, high-breaking Current draw (120 V)...................................... ......................................................................................................... <0.9 Arms Current draw (240 V)................................ ..................................................................................................... ..... <0.45 Arms Input power (120 V) ....................................................................................................................................................... <70 W Input power (240 V) ....................................................................................................................................................... <70 W Transmitter Operating frequency ..................................................................................................................................... 58 kHz (200 Hz)
.................................................................................................................................................................. (sync pulse) 56 kHz Transmit burst duration ................................................................................................................................................. 1.6 ms Transmit current maximum (AMS-1156 pedestals) .................................................................................................. 16 A peak Burst Repetition Rate:
Based on 50 Hz ac .................................................................................................................................. 75 Hz or 37.5 Hz Based on 60 Hz ac ..................................................................................................................................... 90 Hz or 45 Hz Receiver Center frequency ........................................................................................................................................................... 58 kHz Environmental Ambient temperature .................................................................................................................... 0C to 50C (32F to 122F) Relative humidity ..............................................................................................................................0 to 90% non-condensing Enclosure Rating .............................................................................................................................................................. IPX0 Evaluated for altitudes less than 3000 m or 9800 ft Mechanical Height .......................................................................................................................................................... 96.9 mm (3.81 in.) Width ......................................................................................................................................................... 207.0 mm (8.15 in.) Length ..................................................................................................................................................... 532.5 mm (20.96 in.) Weight ............................................................................................................................................................ 2.39 kg (5.27 lb) AMS-9080 CONTROLLER INSTALLATION GUIDE 19 of 22
*8200-0914-01*
8200-0914-01 REV. A Declarations Regulatory Model: ............................................................................................................................................... LFAMS1803 ID list Product name AMS-9080 Controller AMS-1156 Pedestal Digital Remote Alarm Ranger Antennas Satellite Antenna Product code ZE9080 ZA1156-12M-1 and ZA1156-12M-2 ZP1060-W ZP1060-G ZKRANGER-DG and ZKRANGER-3 ZKRXMULLMT Amorphous Core Antenna ZSLOOP-AMRX-1 Regulatory information FCC ID: BVCAMSUSUPC Model AMS-9080 AMS-1156 AMC-1060 UM UPFAF UM POST-M AMS-3004 RK This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. IC: 3506A-AMSUSUPC This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes: (1) lappareil ne doit pas produire de brouillage, et (2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numrique de la classe A est conforme la norme NMB-003 du Canada. A separation distance of 2.0cm or more must be maintained between the antenna of this device and persons during device operation. EMC ............................................................................................................................................................... 47 CFR, Part 15
........................................................................................................................................................................... EN 300 330-2
........................................................................................................................................................................... EN 301 489-3
........................................................................................................................................................................... EN 301 489-1
................................................................................................................................................................................. EN 55032
................................................................................................................................................................................. EN 55024
.................................................................................................................................................................................. ICES-003
................................................................................................................................................................................... RSS-210 Safety ................................................................................................................................... UL/EN 60950-1 (Second edition)
................................................................................................................................................... EN 62368-1 (Second edition)
................................................................................................................................................................. CSA C22.2.60950-1 EQUIPMENT MODIFICATION CAUTION: Equipment changes or modifications not expressly approved by Sensormatic Electronics, LLC, the party responsible for FCC compliance, could void the user's authority to operate the equipment and could create a hazardous condition. See About the product. AMS-9080 CONTROLLER INSTALLATION GUIDE 20 of 22
*8200-0914-01*
8200-0914-01 REV. A Other declarations WARRANTY DISCLAIMER: Sensormatic Electronics, LLC makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Further, Sensormatic Electronics, LLC reserves the right to revise this publication and make changes from time to time in the content hereof without obligation of Sensormatic Electronics, LLC to notify any person of such revision or changes. LIMITED RIGHTS NOTICE: For units of the Department of Defense, all documentation and manuals were developed at private expense and no part of it was developed using Government Funds. The restrictions governing the use and disclosure of technical data marked with this legend are set forth in the definition of limited rights in paragraph (a) (15) of the clause of DFARS 252.227.7013. Unpublished -
rights reserved under the Copyright Laws of the United States. TRADEMARK NOTICE: Sensormatic is a registered trademark of Sensormatic Electronics, LLC. Wiremold is a registered trademark of the Wiremold Company. Other product names mentioned herein may be trademarks or registered trademarks of Sensormatic or other companies. No part of this guide may be reproduced in any form without written permission from Sensormatic Electronics, LLC. AMS-9080 Controller dimensions Figure 9. AMS-9080 Controller top view A 207.0 mm or 8.15 in. Figure 10. AMS-9080 Controller side view A 96.9 mm or 3.81 in. B 532.5 mm or 20.96 in. AMS-9080 CONTROLLER INSTALLATION GUIDE 21 of 22
*8200-0914-01*
8200-0914-01 REV. A AMS-9080 Controller board pinouts Figure 11. AMS-9080 Controller board pinouts A Top coil P3 B Bottom coil P1 IR Input P10 C D Alarm board P5 E Aux Rec 2 P7 F Aux Rec 1 P6 G Peripheral TB2 Network AMS-9080 CONTROLLER INSTALLATION GUIDE Pins 1 2 3 Pins 1 2 3 Pins 1 2 3 4 5 6 7 Pins 1 2 3 4 5 6 7 8 Pins 5 4 3 2 1 Pins 5 4 3 2 1 Pins 1 2 3 4 Signal Bottom coil return Shield Top coil Signal Top coil return Shield Top coil Signal
+12 V IR RX1 IR RX2 IR RX3 IR RX4 Digital ground Chassis ground Signal Power LED-
Alarm CLK-
Audio
+12 V
+5 V Ground Tx Inhibit Ground Signal Ground Antenna D2 return Antenna D2 Antenna D1 return Antenna D1 Signal Ground Antenna C2 return Antenna C2 Antenna C1 return Antenna C1 Signal Color RS-485 low*
RS-485 high*
Ground RS-485 low*
Black Red Green/
silver Black H Service J2 Tx Inhibit connector
**
TB1 I J Flash P18 Override**
K RS-485 P24 Network*
L Secondary P4 M Wired sync P8 N Relays J1 O AC P2 5 6 Pins 1 2 3 4 Pins 1 2 Pins 1 2 Pins 8 7 6 5 4 3 2 1 Pins 5 4 3 2 1 Pins 5 4 3 2 1 Pins 1 2 3 4 5 6 7 8 Pin 1 2 RS-485 high*
Ground Red Green/
silver Signal RS-232 RX RS-232 TX Ground Not used Signal Inhibit Ground Signal Red Silver Green White Ground Ground Sync low (B) Not used Not used Sync high (A) RS-485 low*
RS-485 high*
Signal Color Bottom coil return Black Bottom coil Shield Top coil return Top coil Signal Ground Wired sync arm low Wired sync arm high Tx Burst Low*
Tx Burst High*
Signal Ground Not used NO 2 ARM 2 (COM 2) NC 2 NO 1 ARM 1 (COM 1) NC 1 Signal Primary/L1 Neutral/L2
* The wire color code for RS-485 LO and HI signals varies from option to option. Connect RS-485 options by connecting the RS 485 LO wire to the RS 485 LO pin and the RS 485 HI wire to the RS 485 HI pin.
** To inhibit the Transmitter, short the two pins of TB1. 22 of 22
*8200-0914-01*
8200-0914-01 REV. A
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2019-03-01 | 0.0578 ~ 0.0582 | FAP - Part 15 Anti-Pilferage Device | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2019-03-01
|
||||
1 | Applicant's complete, legal business name |
Tyco Safety Products/Sensormatic
|
||||
1 | FCC Registration Number (FRN) |
0005052626
|
||||
1 | Physical Address |
6600 Congress Ave
|
||||
1 |
Boca Raton, Florida 33487
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
t******@siemic.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
BVC
|
||||
1 | Equipment Product Code |
AMSUSUPC
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
W****** D******** O********
|
||||
1 | Title |
Principal Compliance Engineer
|
||||
1 | Telephone Number |
561-9********
|
||||
1 | Fax Number |
561-9********
|
||||
1 |
b******@tycoint.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 08/28/2019 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | FAP - Part 15 Anti-Pilferage Device | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Electronic Article Surveillance System (EAS) | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Bureau Veritas Consumer Products Services, Inc.
|
||||
1 | Name |
L******** B******
|
||||
1 | Telephone Number |
408-5********
|
||||
1 | Fax Number |
408 5********
|
||||
1 |
l******@siemic.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 0.05780000 | 0.05820000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC