ELECTROMAGNETIC EMISSIONS COMPLIANCE REPORT INTENTIONAL RADIATOR CERTIFICATION TO FCC PART 15 SUBPART C Tag MODEL No.: AW-LMSL-T Trademark: TYLT FCC ID: 2AOAF-900 REPORT NO.: ES190617076W01 ISSUE DATE: July 17, 2019 Prepared for TYLT, inc. 685 Cochran Street #200 Simi Vally, CA 93065 Bldg 69, Majialong Industry Zone, Nanshan District, Shenzhen, Prepared by EMTEK (SHENZHEN) CO., LTD. Guangdong, China TEL: 86-755-26954280 FAX: 86-755-26954282 TRF NO. FCC Part 15C Page 1 of 27 Report No.: ES190617076W01 Ver.1.0 TABLE OF CONTENT Test Report Description Page 1. SUMMARY OF TEST RESULTS .......................................................................................................................... 5 2. GENERAL INFORMATION .................................................................................................................................. 6 2.1. Description of Device (EUT) ........................................................................................................................... 6 2.2. Input / Output Ports ......................................................................................................................................... 6 2.3. Independent Operation Modes ....................................................................................................................... 7 2.4. Test Manner .................................................................................................................................................... 7 2.5. Description of Test Facility .............................................................................................................................. 7 2.6. Test Software .................................................................................................................................................. 7 2.7. Description of Support Device ........................................................................................................................ 8 2.8. Measurement Uncertainty............................................................................................................................... 8 3. MEASURING DEVICE AND TEST EQUIPMENT ................................................................................................ 9 3.1. Conducted Emission Test Equipment ............................................................................................................. 9 3.2. For 3m Radiated Emission Measurement 9K-30M (3m chamber 1#) ............................................................ 9 3.3. For 3m Radiated Emission Measurement 30M-1G (3m chamber 1#) ......................................................... 9 4. 20DB BANDWIDTH ........................................................................................................................................... 10 4.1. Test Procedure .............................................................................................................................................. 10 4.2. Test Results .................................................................................................................................................. 10 5. POWER LINE CONDUCTED EMISSION MEASUREMENT .............................................................................. 11 5.1. Block Diagram of Test Setup ......................................................................................................................... 11 5.2. Limits .............................................................................................................................................................. 11 5.3. Test Procedure ............................................................................................................................................... 11 5.4. Measuring Results ........................................................................................................................................ 12 6. RADIATED EMISSION TEST ............................................................................................................................. 15 6.1. Measurement Procedure .............................................................................................................................. 15 6.2. Test SET-UP (Block Diagram of Configuration) ............................................................................................ 15 6.3. Measurement Equipment Used .................................................................................................................... 16 6.4. Radiated Emission Limit ............................................................................................................................... 16 6.5. Measurement Result..................................................................................................................................... 18 7. PHOTOGRAPHS ................................................................................................................................................ 26 7.1. Photos of Power Line Conducted Emission Measurement .......................................................................... 26 7.2. Photos of Radiation Emission Measurement(9KHz-30MHz)........................................................................ 26 7.3. Photos of Radiation Emission Measurement(30MHz-1GHz) ....................................................................... 27 TRF NO. FCC Part 15C Page 2 of 27 Report No.: ES190617076W01 Ver.1.0 Applicant Address Manufacturer Address EUT TEST REPORT DESCRIPTION
: TYLT, inc.
: 685 Cochran Street #200 Simi Vally, CA 93065
: Mei Shun He Electronic Limited
: 301, 8th Building, No.69 Xikeng Road, Xikeng Community, Fucheng Street, Longhua District, 518110, Shenzhen City, China.
: Tag Model Name
: AW-LMSL-T
: TYLT Trademark Measurement Procedure Used:
APPLICABLE STANDARDS STANDARD FCC 47 CFR Part 2, Subpart J FCC 47 CFR Part 15, Subpart C TEST RESULT PASS The above equipment was tested by SHENZHEN EMTEK CO., LTD. The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.10 (2013) and the energy emitted by the sample EUT tested as described in this report is in compliance with conducted and radiated emission limits of FCC Rules Part 15C The test results of this report relate only to the tested sample identified in this report. Date of Test :
June 28, 2019 to July 3, 2019 Prepared by :
Reviewer :
Approved & Authorized Signer :
Yaping Shen/Editor Joe Xia/Supervisor Lisa Wang/Manager TRF NO. FCC Part 15C Page 3 of 27 Report No.: ES190617076W01 Ver.1.0 Modified Information Revision Data Report No. ES190617076W01 July 17, 2019 Version Ver.1.0 Summary Original Version TRF NO. FCC Part 15C Page 4 of 27 Report No.: ES190617076W01 Ver.1.0 1. SUMMARY OF TEST RESULTS EMISSION Description of Test Item Conducted Emission Radiated Emission Standard & Limits FCC Part 15, Subpart C- Section 15.207 ANSI C63.10-2013 FCC Part 15, Subpart C- Section 15.209 ANSI C63.10-2013 Results Pass Pass Note: N/A is an abbreviation for Not Applicable. TRF NO. FCC Part 15C Page 5 of 27 Report No.: ES190617076W01 Ver.1.0 2. GENERAL INFORMATION 2.1. Description of Device (EUT) EUT Model Number Power Rating
:
:
:
:
Tag AW-LMSL-T Input:DC5V,1A Output:DC5V,300mA 325KHz Operation Frequency for WPT Modulation Antenna Type:
Date of Received Date of Test
: ASK
:
:
:
Integral Antenna(Induction coil) June 26, 2019 June 28, 2019 to July 1, 2019 2.2. Input / Output Ports Port
#
1 2 Name Enclosure DC IN port Type*
N/E I/O Cable Max. >3m Cable Shielded
--
No
--
--
Comments None 1 port
* Note: For the purposes of the present document, the following symbols apply:
AC DC N/E I/O TP AC Power Port DC Power Port Non-Electrical Signal Input or Output Port (Not Involved in Process Control) Telecommunication Ports TRF NO. FCC Part 15C Page 6 of 27 Report No.: ES190617076W01 Ver.1.0 2.3. Independent Operation Modes A 1. ON Charging for iPhone by WPT(Full load) 2.4. Test Manner Test Items Conducted Emission Radiated Emission Test Voltage AC 120V/60Hz AC 120V/60Hz Operation Modes Mode A.1 Mode A.1 2.5. Description of Test Facility Site Description EMC Lab.
: Accredited by CNAS, 2018.11.30 The certificate is valid until 2022.10.28 The Laboratory has been assessed and proved to be in compliance with CNAS-CL01:2006 (identical to ISO/IEC 17025:2017) The Certificate Registration Number is L2291 Accredited by TUV Rheinland Shenzhen 2018.03.30 The Laboratory has been assessed according to the requirements ISO/IEC 17025 Accredited by FCC, August 09, 2018 Designation Number: CN1204 Test Firm Registration Number: 882943 Accredited by A2LA, August 08, 2018 The Certificate Registration Number is 4321.01 Accredited by Industry Canada, November 09, 2018 The Conformity Assessment Body Identifier is CN0008
: EMTEK(SHENZHEN) CO., LTD.
: Bldg 69, Majialong Industry Zone, Nanshan District, Shenzhen, Guangdong, China Name of Firm Site Location 2.6. Test Software Item Conducted Emission Radiated Emission Software
: EMTEK(Ver.CON-03A1)-Shenzhen
: EMTEK(Ver.RA-03A1)-Shenzhen TRF NO. FCC Part 15C Page 7 of 27 Report No.: ES190617076W01 Ver.1.0 2.7. Description of Support Device No. 1. 2. Equipment iPhone Adapter Trade name Apple Aohal Model A1526 A&A-050200U-US1 S/N N/A N/A Power Cord N/A N/A 2.8. Measurement Uncertainty Test Item Conducted Emission Uncertainty Radiated Emission Uncertainty
(3m Chamber) Uncertainty
: 3.16dB(9k~150kHz Conduction 2#) 2.90dB(150k-30MHz Conduction 2#)
: 3.78dB (30M~1GHz Polarize: H) 4.27dB (30M~1GHz Polarize: V) 4.46dB (1~6GHz) TRF NO. FCC Part 15C Page 8 of 27 Report No.: ES190617076W01 Ver.1.0 3. MEASURING DEVICE AND TEST EQUIPMENT 3.1. Conducted Emission Test Equipment EQUIPMENT TYPE Test Receiver L.I.S.N. MFR Rohde & Schwarz Schwarzbeck 50 Coaxial Switch Anritsu Pulse Limiter Voltage Probe I.S.N Rohde & Schwarz Rohde & Schwarz Rohde & Schwarz MODEL NUMBER ESCS30 NNLK8129 MP59B ESH3-Z2 TK9416 ENY22 SERIAL NUMBER 828985/018 8129203 M20531 100006 N/A 1109.9508.02 LAST CAL. 05/20/2019 05/20/2019 05/20/2019 05/20/2019 05/20/2019 05/20/2019 DUE CAL. 05/19/2020 05/19/2020 05/19/2020 05/19/2020 05/19/2020 05/19/2020 3.2. For 3m Radiated Emission Measurement 9K-30M (3m chamber 1#) Equipment EMI Test Receiver Loop Antenna Cable Manufacturer Rohde & Schwarz Schwarzbeck Cable Model No. ESU FMZB 1519 3M 6M SF104-26.5 SF104-26.5 Serial No. 1302.6005.26 1519-012 295838/4 295840/4 Last Cal. 05/20/2019 05/20/2019 05/20/2019 DUE CAL. 05/19/2020 05/19/2020 05/19/2020 05/20/2019 05/19/2020 3.3. For 3m Radiated Emission Measurement 30M-1G (3m chamber 1#) Manufacturer Rohde & Schwarz HP Schwarzbeck Schwarzbeck Rosenberger Schwarzbeck Schwarzbeck Model No. ESU 8447F VULB9163 AK9513 N/A AK9513 AK9513 Serial No. 1302.6005.26 2944A07999 142 ACRX1 FP2RX2 CRPX1 CRRX2 Last Cal. 05/20/2019 05/20/2019 05/20/2019 05/20/2019 05/20/2019 05/20/2019 05/20/2019 Cal. Interval 05/19/2020 05/19/2020 05/19/2020 05/19/2020 05/19/2020 05/19/2020 05/19/2020 Equipment EMI Test Receiver Pre-Amplifier Bilog Antenna Cable Cable Cable Cable TRF NO. FCC Part 15C Page 9 of 27 Report No.: ES190617076W01 Ver.1.0 4. 20DB BANDWIDTH 4.1. Test Procedure Set to the maximum power setting and enable the EUT transmit continuously Set RBW = 3kHz. Set the video bandwidth (VBW) =10kHz. Set Span= 20KHz Set Detector = Peak. Set Trace mode = max hold. Set Sweep = auto couple. Measure and record the results in the test report. 4.2. Test Results Temperature:
Humidity:
24 53 %
20dB Band=742Hz Test Date:
Test By:
July 03, 2019 KK TRF NO. FCC Part 15C Page 10 of 27 Report No.: ES190617076W01 Ver.1.0 5. POWER LINE CONDUCTED EMISSION MEASUREMENT 5.1. Block Diagram of Test Setup Metal ground plane Test receiver EUT AE Metal ground plane LISN 80cm 80cm 50 LISN LISN: Line Impedance Stabilization Network AE: Associated equipment EUT: Equipment under test 5.2. Limits FCC Part 15.207 Frequency
(MHz)
~
~
~
0.50 5.00 30.00 0.15 0.50 5.00 Limit (dBV) Quasi-peak Level 66.0 ~ 56.0 *
Average Level 56.0 ~ 46.0 *
56.0 60.0 46.0 50.0 NOTE1-The lower limit shall apply at the transition frequencies. NOTE2-The limit decreases linearly with the logarithm of the frequency in the range 0.15MHz to 0.50MHz. 5.3. Test Procedure The EUT was placed on a desk 0.8 m height from the metal ground plane and 0.4 m from the conducting wall of the shielding room and it was kept at least 0.8 m from any other grounded conducting surface. The size of the table will nominally be 1.5 m x1.0 m. The rear of the arrangement shall be flush with the back of the supporting tabletop unless that would not be possible or typical of normal use. All units of equipment forming the system under test (includes the EUT as well as connected peripherals and associated equipment or devices) shall be arranged such that a nominal 0.1 m separation is achieved between the neighboring units. Connect EUT to the power mains through a line impedance stabilization network (LISN). Where the mains cable supplied by the manufacturer is longer than 1 m, the excess should be folded at the centre into a bundle no longer than 0.4 m, so that its length is shortened to 1 m. All the support units are connecting to the other LISN. The LISN provides 50 ohm coupling impedance for the measuring instrument. TRF NO. FCC Part 15C Page 11 of 27 Report No.: ES190617076W01 Ver.1.0 Both sides of AC line were checked for maximum conducted interference. The frequency range from 150 kHz to 30 MHz was sweep. Set the test-receiver system to quasi peak detect function and average detect function, and to measure the conducted emissions values. Test results were obtained from the following equation:
Emission Level (dBV) = LISN Factor (dB) + Cable Loss (dB) + Reading (dBV) Margin (dB) = Emission Level (dBV) - Limit (dBV) 5.4. Measuring Results PASS. TRF NO. FCC Part 15C Page 12 of 27 Report No.: ES190617076W01 Ver.1.0 TRF NO. FCC Part 15C Page 13 of 27 Report No.: ES190617076W01 Ver.1.0 TRF NO. FCC Part 15C Page 14 of 27 Report No.: ES190617076W01 Ver.1.0 6. RADIATED EMISSION TEST 6.1. Measurement Procedure 1. The EUT was placed on a turn table which is 0.8m above ground plane. 2. Maximum procedure was performed on the six highest emissions to ensure EUT compliance. 3. And also, each emission was to be maximized by changing the polarization of receiving antenna both horizontal and vertical. 4. Repeat above procedures until all frequency measured were complete. 5. Use the following receiver/spectrum analyzer settings:
Span = wide enough to fully capture the emission being measured RBW=200Hz for 9KHz to 150KHz, RBW=9kHz for 150KHz to 30MHz, RBW=120KHz for 30MHz to 1GHz VBW 3*RBW Sweep = auto Detector function = QP Trace = max hold 6.2. Test SET-UP (Block Diagram of Configuration)
(A) Radiated Emission Test Set-Up, Frequency Below 30MHz Turntable EUT 3m 0.8 m Test Receiver Ground Plane Coaxial Cable
(B) Radiated Emission Test Set-Up, Frequency Below 1000MHz 3m 0.8m Turntable EUT Test Receiver Ground Plane 1m to 4m Coaxial Cable TRF NO. FCC Part 15C Page 15 of 27 Report No.: ES190617076W01 Ver.1.0 6.3. Measurement Equipment Used EQUIPMENT TYPE EMI Test Receiver Pre-Amplifier Bilog Antenna Loop Antenna Horn Antenna Horn Antenna Cable Cable Cable Cable MFR MODEL NUMBER Rohde & Schwarz ESU HP Schwarzbeck ARA Schwarzbeck Schwarzbeck Schwarzbeck Rosenberger Schwarzbeck Schwarzbeck 8447D VULB9163 PLA-1030/B BBHA 9170 BBHA 9120 AK9513 N/A AK9513 AK9513 SERIAL NUMBER 1302.6005.26 2944A07999 142 1029 BBHA9170399 D143 ACRX1 FP2RX2 CRPX1 CRRX2 LAST CAL. CAL DUE. 05/20/2019 05/20/2019 05/20/2019 05/20/2019 05/20/2019 05/20/2019 05/20/2019 05/20/2019 05/20/2019 05/20/2019 05/20/2020 05/20/2020 05/20/2020 05/20/2020 05/20/2020 05/20/2020 05/20/2020 05/20/2020 05/20/2020 05/20/2020 6.4. Radiated Emission Limit The emissions from an intentional radiator shall not exceed the field strength levels specified in the following table 15.209(a):
Frequency
(MHz) 0.009 0.490 0.490 1.705 1.705 30.00 30.0 88.0 88.0 216.0 216.0 960.0 Above 960.0 Field Strength Limitation
(uV/m) 2400 / F(KHz) 24000 / F(KHz) 30 100 150 200 500 FCC Part 15.209 Field Strength Limitation Frequency tion at 3m Measurement Dist
(uV/m) Dist 300m 10000 * 2400/F(KHz) 30m 100 * 24000/F(KHz) 30m 3m 3m 3m 3m 100 150 200 500 100* 30
(dBuV/m) 20log 2400/F(KHz) + 80 20log 24000/F(KHz) + 40 20log 30 + 40 20log 100 20log 150 20log 200 20log 500 TRF NO. FCC Part 15C Page 16 of 27 Report No.: ES190617076W01 Ver.1.0 15.205 Restricted bands of operation Remark: 1. Emission level in dBuV/m=20 log (uV/m) 2. Measurement was performed at an antenna to the closed point of EUT distance of meters. 3. Only spurious frequency is permitted to locate within the Restricted Bands specified in provision of 15.205, and the emissions located in restricted bands also comply with 15.209 limit. TRF NO. FCC Part 15C Page 17 of 27 Report No.: ES190617076W01 Ver.1.0 6.5. Measurement Result 9KHz-150KHz:
TRF NO. FCC Part 15C Page 18 of 27 Report No.: ES190617076W01 Ver.1.0 TRF NO. FCC Part 15C Page 19 of 27 Report No.: ES190617076W01 Ver.1.0 TRF NO. FCC Part 15C Page 20 of 27 Report No.: ES190617076W01 Ver.1.0 150KHz-30MHz:
TRF NO. FCC Part 15C Page 21 of 27 Report No.: ES190617076W01 Ver.1.0 TRF NO. FCC Part 15C Page 22 of 27 Report No.: ES190617076W01 Ver.1.0 TRF NO. FCC Part 15C Page 23 of 27 Report No.: ES190617076W01 Ver.1.0 30MHz-1GHz:
TRF NO. FCC Part 15C Page 24 of 27 Report No.: ES190617076W01 Ver.1.0 TRF NO. FCC Part 15C Page 25 of 27 Report No.: ES190617076W01 Ver.1.0 7. PHOTOGRAPHS 7.1.Photos of Power Line Conducted Emission Measurement 7.2.Photos of Radiation Emission Measurement(9KHz-30MHz) TRF NO. FCC Part 15C Page 26 of 27 Report No.: ES190617076W01 Ver.1.0 7.3.Photos of Radiation Emission Measurement(30MHz-1GHz)
----------------The end----------------