VERA-P1 series Host-based V2X transceiver module Data Sheet Abstract This technical data sheet describes the VERA-P1 series transceiver module that enables development of electronics for Vehicle-to-
Everything (V2X) communication systems. The VERA-P1 series includes an integrated MAC/LLC/Baseband processor and the required RF front-end components. It is connected to a host processor through a USB or SPI interface. www.u-blox.com UBX-17004377 - R04 VERA-P1 series - Data Sheet Document Information Title Subtitle VERA-P1 series Host-based V2X transceiver module Document type Data Sheet Document number UBX-17004377 Revision and date R04 7-Dec-2017 Disclosure restriction Confidential Product Status Corresponding content status Functional Sample Draft For functional testing. Revised and supplementary data will be published later. In Development /
Prototype Objective Specification Target values. Revised and supplementary data will be published later. Engineering Sample Advance Information Data based on early testing. Revised and supplementary data will be published later. Initial Production Early Prod. Information Data from product verification. Revised and supplementary data may be published later. Mass Production /
End of Life Production Information Final product specification. This document applies to the following products:
Product name Type number Firmware version PCN reference Product Status VERA-P171 VERA-P173 VERA-P174 VERA-P171-00A-00 VERA-P173-00A-00 VERA-P174-00A-00 N/A N/A N/A N/A N/A N/A Prototype Prototype Prototype u-blox reserves all rights to this document and the information contained herein. Products, names, logos and designs described herein may in whole or in part be subject to intellectual property rights. Reproduction, use, modification or disclosure to third parties of this document or any part thereof without the express permission of u-blox is strictly prohibited. The information contained herein is provided as is and u-blox assumes no liability for the use of the information. No warranty, either express or implied, is given, including but not limited, with respect to the accuracy, correctness, reliability and fitness for a particular purpose of the information. This document may be revised by u-blox at any time. For most recent documents, visit www.u-blox.com. Copyright 2017, u-blox AG. u-blox is a registered trademark of u-blox Holding AG in the EU and other countries. UBX-17004377 - R04 Confidential Contents Page 2 of 28 VERA-P1 series - Data Sheet Contents Contents .............................................................................................................................. 3 1 Functional description .................................................................................................. 5 1.1 Overview .............................................................................................................................................. 5 Product features ................................................................................................................................... 5 1.2 Block diagrams ..................................................................................................................................... 6 1.3 1.4 Product description ............................................................................................................................... 6 Supported features ............................................................................................................................... 7 1.5 2 Host interfaces ............................................................................................................. 8 USB interface ........................................................................................................................................ 8 SPI interface .......................................................................................................................................... 8 2.1 2.2 3 Pin Definition ................................................................................................................ 9 Pin description ...................................................................................................................................... 9 3.1 4 Electrical specification ................................................................................................ 14 4.1 Absolute maximum ratings ................................................................................................................. 14 4.2 Operating conditions .......................................................................................................................... 14 Digital pad ratings .............................................................................................................................. 14 4.3 4.4 Peak current consumption .................................................................................................................. 15 Current consumption.......................................................................................................................... 15 4.5 4.6 Radio specifications ............................................................................................................................ 16 5 Mechanical specifications .......................................................................................... 18 Physical dimensions ............................................................................................................................ 18 5.1 6.1 6 Qualification and approvals ...................................................................................... 20 Approvals ........................................................................................................................................... 20 European Union regulatory compliance ....................................................................................... 20 FCC compliance .......................................................................................................................... 20 IC compliance.............................................................................................................................. 20 FCC and IC IDs ............................................................................................................................ 20 Certification in other countries .................................................................................................... 21 6.1.1 6.1.2 6.1.3 6.1.4 6.1.5 7.1 7.1.1 7.1.2 7 Product handling & soldering .................................................................................... 22 Packaging ........................................................................................................................................... 22 Reels ........................................................................................................................................... 22 Tapes .......................................................................................................................................... 22 Shipment, storage and handling ......................................................................................................... 22 7.2.1 Moisture sensitivity levels ............................................................................................................. 22 7.2.2 Mounting process and soldering recommendations ..................................................................... 23 ESD handling precautions ............................................................................................................ 24 7.2.3 7.2 UBX-17004377 - R04 Confidential Contents Page 3 of 28 VERA-P1 series - Data Sheet 8 Labeling and ordering information ........................................................................... 25 8.1 Product labeling .................................................................................................................................. 25 8.2 Explanation of codes........................................................................................................................... 25 8.3 Ordering codes ................................................................................................................................... 25 Appendix .......................................................................................................................... 26 Glossary ............................................................................................................................ 26 Related documents........................................................................................................... 27 Revision history ................................................................................................................ 27 Contact .............................................................................................................................. 28 UBX-17004377 - R04 Confidential Contents Page 4 of 28 VERA-P1 series - Data Sheet 1 Functional description 1.1 Overview The VERA-P1 series are compact, embedded transceiver modules that enables development of electronics for Vehicle-to-Everything (V2X) communication systems. These automotive grade modules are designed for applications such as traffic safety, intelligent traffic management and entertainment. The modules can be used for in-vehicle units (OBU - On Board Unit) their use in V2X infrastructure (RSU - Road Side Unit) is intended, but not authorized yet. The VERA-P1 series modules provide superior performance compared to V2X systems based on consumer-grade Wi-Fi chipsets, especially at high vehicle speeds and in non-line-of-sight (NLOS) conditions. The VERA-P1 series includes an integrated MAC/LLC/Baseband processor and the required RF front-end components. The module is connected to a host processor through USB or SPI interface. Both interfaces can be used for data communication and firmware download. 1.2 Product features Table 1: VERA-P1 series main features summary UBX-17004377 - R04 Confidential Functional description Page 5 of 28 1.3 Block diagrams VERA-P1 series - Data Sheet Figure 1: Block diagram of VERA-P171 Figure 2: Block diagram of VERA-P173 and VERA-P174 1.4 Product description Model VERA-P171 VERA-P173 VERA-P174 Description Single channel, no antenna diversity, one antenna Single channel, antenna diversity, two antennas Dual channel or single channel with antenna diversity, two antennas Table 2: Product description UBX-17004377 - R04 Confidential Functional description Page 6 of 28 1.5 Supported features VERA-P1 series - Data Sheet Frequency band 5.850 5.925 MHz (channels 172, 174, 176, 178, 180, 182, 184) Compliance with WAVE and ETSI ITS G5 for US and Europe operations USB and SPI1 host interfaces Channel bandwidth 10 MHz2 Data rates 3, 4.5, 6, 9, 12, 18, 24, 27 Mbps Antenna diversity (VERA-P173, VERA-P174) CDD for TX and MRC for RX mode Operation temperature -40 C to +95 C Dimensions 29.6 x 24.8 x 3.5 mm TX output power from -10 to +23 dBm (Class C), RX sensitivity -97 dBm at 3 Mbps Power supply 3.3 V and 5.0 V, 4 W maximum 1 SPI is not recommended as the main host interface for communication due to performance limitations. 2 Support for 20 MHz mode is planned for future firmware releases subject to certain limitations, as the requirements for 20 MHz operation have not been fully specified. UBX-17004377 - R04 Confidential Functional description Page 7 of 28 VERA-P1 series - Data Sheet 2 Host interfaces 2.1 USB interface The VERA-P1 series module supports a USB 2.0 high-speed interface for firmware loading (booting) and high speed data transfer (> 200 Mbps). The USB interface of the module is powered with 3.3 V supply voltage. The module acts as a device on the USB bus. 2.2 SPI interface The VERA-P1 series module supports an SPI interface for firmware loading (booting) and data communication. Firmware can be loaded by the host processor while the module operates as a slave or from the FLASH memory while the module is in the master mode. When the module is configured as a master, it needs a USB interface connection for communication to the host. The interface is capable of full-duplex operation in master or slave mode. The maximum clock rate is 50 MHz in master mode, and 25 MHz in slave mode3. 3 SPI host interface for data communication in slave mode is tested only with 15 MHz clock rate. UBX-17004377 - R04 Confidential Host interfaces Page 8 of 28 VERA-P1 series - Data Sheet 3 Pin Definition 3.1 Pin description Figure 3: Pin allocation (top view) UBX-17004377 - R04 Confidential Pin Definition Page 9 of 28 VERA-P1 series - Data Sheet Pin type Ground Ground Power domain Description
-
-
Ground Ground I VIO Module Reset, has internal pull-up 100k to VIO Ground Power Ground
-
Power Ground
-
Ground
-
-
-
-
-
-
Ground Power Ground
-
-
Ground Ground Ground RF I/O Ground Ground
-
Ground Ground
-
Ground Ground
-
Ground Ground
-
Ground Ground RF I/O Ground Ground Ground
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Ground Baseband/Radio supply (3.0 to 3.6V) Ground Leave unconnected I/O voltage (1.8/2.5/3.3V), in case of 1.8V pin 8 can get supply from pin B7 Ground Leave unconnected Ground Leave unconnected Leave unconnected Leave unconnected Leave unconnected Leave unconnected Leave unconnected Ground Antenna 1 radio front-end supply (4.5 to 5.5V) Ground Leave unconnected Leave unconnected Ground Ground Ground Antenna 1 Ground Ground Leave unconnected Ground Ground Leave unconnected Ground Ground Leave unconnected Ground Ground Leave unconnected Ground Ground Antenna 2 Ground Ground Ground No. Name A1 A2 A3 A4 A5 A6 A7 A8 A9 GND GND RSTn GND 3V3 GND NC VIO GND A10 NC A11 GND A12 NC A13 NC A14 NC A15 NC A16 NC A17 NC A18 GND A19 5V0_A1 A20 GND A21 NC A22 NC A23 GND A24 GND A25 GND A26 ANT1 A27 GND A28 GND A29 NC A30 GND A31 GND A32 NC A33 GND A34 GND A35 NC A36 GND A37 GND A38 NC A39 GND A40 GND A41 ANT2 A42 GND A43 GND A44 GND UBX-17004377 - R04 Confidential Pin Definition Page 10 of 28 VERA-P1 series - Data Sheet Power domain Description
-
-
VIO VIO VIO
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Antenna 2 radio front-end supply (4.5 to 5.5 V) Ground SPI Bus SPI Bus Optional SPI CS Ground Leave unconnected Leave unconnected Leave unconnected Leave unconnected Leave unconnected Leave unconnected Ground Leave unconnected Leave unconnected Leave unconnected Ground USB Bus USB Bus USB VBUS detect input Ground Ground Ground Leave unconnected Ground No. Name A45 5V0_A2 A46 GND A47 SPI_MOSI A48 SPI_MISO A49 MOD_IO_SPARE Pin type Power Ground I/O I/O I/O A50 GND Ground A51 NC A52 NC A53 NC A54 NC A55 NC A56 NC
-
-
-
-
-
-
A57 GND Ground A58 NC A59 NC A60 NC
-
-
-
A61 GND Ground I/O I/O I Ground Ground Ground
-
Ground A62 USB_DN A63 USB_DP A64 USB_VBUS A65 GND A66 GND A67 GND A68 NC A69 GND A70 1PPS A71 GND A72 NC A73 NC A74 NC A75 NC A76 NC A77 GND A78 NC A79 BOOT_0 A80 NC A81 GND A82 NC A83 NC A84 GND B1 B2 B3 B4 B5 NC NC GND 3V3 GND I 1V8 One pulse per second input Ground
-
-
-
-
-
Ground
-
I
-
Ground
-
-
Ground
-
-
Ground Power Ground
-
-
-
-
-
-
-
-
Ground Leave unconnected Leave unconnected Leave unconnected Leave unconnected Leave unconnected Ground Leave unconnected VIO Boot mode configuration
-
-
-
-
-
-
-
-
-
-
Leave unconnected Ground Leave unconnected Leave unconnected Ground Leave unconnected Leave unconnected Ground Baseband/Radio supply (3.0 to 3.6 V) Ground UBX-17004377 - R04 Confidential Pin Definition Page 11 of 28 No. Name B6 B7 B8 B9 NC 1V8 GND NC B10 GND B11 B12 B13 B14 B15 B16 NC NC NC NC NC NC B17 GND B18 5V0_A1 B19 GND B20 B21 NC NC B22 GND B23 GND B24 GND B25 B26 B27 NC NC NC B28 GND B29 GND B30 GND B31 GND B32 GND B33 GND B34 B35 B36 NC NC NC B37 GND B38 GND B39 GND B40 5V0_A2 B41 GND B42 SPI_SCK B43 SPI_CSn B44 NC B45 GND B46 B47 B48 B49 B50 NC NC NC NC NC Pin type
-
O Ground
-
Ground
-
-
-
-
-
-
Ground Power Ground
-
-
Ground Ground Ground
-
-
-
Ground Ground Ground Ground Ground Ground
-
-
-
Ground Ground Ground Power Ground I/O I/O
-
Ground
-
-
-
-
-
VERA-P1 series - Data Sheet Power domain Description
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
VIO VIO
-
-
-
-
-
-
-
Leave unconnected 1.8 V supply output, can be connected to pin 8 only as a VIO voltage source Ground Leave unconnected Ground Leave unconnected Leave unconnected Leave unconnected Leave unconnected Leave unconnected Leave unconnected Ground Antenna 1 radio front-end supply (4.5 to 5.5 V) Ground Leave unconnected Leave unconnected Ground Ground Ground Leave unconnected Leave unconnected Leave unconnected Ground Ground Ground Ground Ground Ground Leave unconnected Leave unconnected Leave unconnected Ground Ground Ground Antenna 2 radio front-end supply (4.5 to 5.5 V) Ground SPI Bus SPI Bus Leave unconnected Ground Leave unconnected Leave unconnected Leave unconnected Leave unconnected Leave unconnected UBX-17004377 - R04 Confidential Pin Definition Page 12 of 28 VERA-P1 series - Data Sheet No. Name B51 NC B52 GND B53 B54 B55 NC NC NC Pin type
-
Ground
-
-
-
B56 GND Ground B57 B58 B59 B60 B61 B62 NC NC NC NC NC NC
-
-
-
-
-
-
B63 GND Ground B64 B65 B66 B67 B68 B69 NC NC NC NC NC NC
-
-
-
-
-
-
B70 GND Ground B71 BOOT_2 B72 BOOT_1 B73 NC B74 GND B75 B76 NC NC EP GND I I
-
Ground
-
-
Ground Power domain Description
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Leave unconnected Ground Leave unconnected Leave unconnected Leave unconnected Ground Leave unconnected Leave unconnected Leave unconnected Leave unconnected Leave unconnected Leave unconnected Ground Leave unconnected Leave unconnected Leave unconnected Leave unconnected Leave unconnected Leave unconnected Ground VIO VIO Boot mode configuration Boot mode configuration
-
-
-
-
-
Leave unconnected Ground Leave unconnected Leave unconnected 20 Ground/Thermal exposed pads, connect to the ground Table 3: VERA-P1 series pin description UBX-17004377 - R04 Confidential Pin Definition Page 13 of 28 VERA-P1 series - Data Sheet 4 Electrical specification Stressing the device above one or more of the ratings listed in the Absolute Maximum Rating section may cause permanent damage. These are stress ratings only. Operating the module at these or at any conditions other than those specified in the Operating conditions section of this document should be avoided. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Operating condition ranges define those limits within which the functionality of the device is guaranteed. Where application information is given, it is advisory only and does not form part of the specification. 4.1 Absolute maximum ratings Symbol Description 5V0_A1, 5V0_A2 Power supply voltage 5.0 V 3V3 VIO TSTORAGE Power supply voltage 3.3 V I/O supply voltage 1.8 V/2.5 V/3.3 V Storage temperature Table 4: Absolute maximum ratings Min.
-0.3
-0.3
-0.3
-40 Max. 6.0 3.9 3.9
+95 Units V V V C The product is not protected against overvoltage or reversed voltages. If necessary, voltage spikes exceeding the power supply voltage specification, given in table above, must be limited to values within the specified boundaries by using appropriate protection devices. 4.2 Operating conditions Symbol Parameter 5V0_A1, 5V0_A2 3V3 VIO TA Ripple Noise Power supply voltage 5.0 V Power supply voltage 3.3 V I/O supply voltage 1.8 V/2.5 V/3.3 V Ambient operating temperature Peak-to-peak voltage ripple on 5V0 and 3V3 supply lines. Table 5: Operating conditions 4.3 Digital pad ratings Min. 4.5 3.0 1.65 2.3 3.0
-40
-
Typ 5.0 3.3 1.8 2.5 3.3
-
-
Max. 5.5 3.6 1.95 2.8 3.6
+95 10 Units V V V V C mV Symbol Parameter Conditions Min. Max. Units VIH VIL VHYS VOH VOH Input high voltage Input low voltage Input hysteresis Output high voltage Output low voltage Table 6: Digital pad ratings 0.7*VIO4
-0.3 0.18 IOmax = 5 mA VIO-0.4 IOmax = -5 mA
-
VIO1 0.65
-
-
0.4 V V V V V 4 1PPS pad always use 1.8 V internally generated IO supply regardless of the VIO pad voltage. 5 RSTn pad internally pulled high to VIO voltage by 100k. During reset it should be below 0.2 V. UBX-17004377 - R04 Confidential Electrical specification Page 14 of 28 VERA-P1 series - Data Sheet 4.4 Peak current consumption Operation Mode RX TX
+23 dBm
+15 dBm
+10 dBm
+0 dBm 3V3 700 700 700 700 700 Peak current6 (mA) VIO7 TBD TBD TBD TBD TBD 5V0_A1 5V0_A2 35 500 TBD TBD TBD 35 500 TBD TBD TBD Table 7: Peak current consumption 4.5 Current consumption Power consumption for different operation modes TBD 6 Peak values are shown. The average current for full operation mode strongly depends on RX/TX time ratio and remains within the range between the peak values of RX and TX. 7 VIO current is shown for 1.8 V I/O voltage. UBX-17004377 - R04 Confidential Electrical specification Page 15 of 28 4.6 Radio specifications Parameter RF Frequency Range Modulation Supported Data Rates Supported Bandwidth Maximum Transmit Power Minimum Transmit Power Receiver sensitivity Operation Mode 802.11p 802.11p 802.11p 802.11p 802.11p 802.11p 802.11p 10 MHz, no multipath, 25 C 10 MHz, NLoS (Non-line-of-sight), 25 C VERA-P1 series - Data Sheet Specification 5.85 5.925 GHz OFDM 3, 4.5, 6, 9, 12, 18, 24, 27 Mbps 10 MHz 20 dBm 2 dB
-10 dBm 3 Mbps
-98 dBm typ., -95 dBm min. 4.5 Mbps
-96 dBm typ., -93 dBm min. 6 Mbps 9 Mbps
-95 dBm typ., -92 dBm min.
-93 dBm typ., -90 dBm min. 12 Mbps
-90 dBm typ., -87 dBm min. 18 Mbps
-86 dBm typ., -83 dBm min. 24 Mbps
-82 dBm typ., -79 dBm min. 27 Mbps
-80 dBm typ., -77 dBm min. 3 Mbps
-95 dBm typ., -92 dBm min. 4.5 Mbps
-92 dBm typ., -89 dBm min. 6 Mbps 9 Mbps
-88 dBm typ., -85 dBm min.
-86 dBm typ., -83 dBm min. 12 Mbps
-85 dBm typ., -82 dBm min. 18 Mbps
-82 dBm typ., -79 dBm min. 24 Mbps 27 Mbps na na Receiver maximum operating input level 802.11p RSSI accuracy 802.11p Over tempearature range Centre frequency and symbol clock tolerance 802.11p Transmitter spectral flatness 802.11p All modulation modes Transmitter centre frequency leakage Transmit power control step size Transmit power control accuracy Table 8: Radio specifications 802.11p 802.11p 802.11p Over tempearature range
-20 dBm
+/-2 dB
+/-10 ppm
< +/-2 dB
< -15 dB 0.5 dB
+/-2 dB Table 9 shows the Highway NLoS (Non-line-of-sight) channel parameters that are used to obtain the receiver sensitivity values in Table 8. This channel was used in RF testing at the third ETSI Plug test (CMS3). Each tap is faded using Pure Doppler, but the second antenna has a Doppler increased by 11 Hz, which prevents phase synchronization of channels. The RX Power listed in Table 8 refers to the power of Tap 0. The values presented are typical values, measured at +25 C. Tap#
Relative Power (dB) Delay (ns) Doppler Frequency (Hz) 0 1 2 3 0
-2
-5
-7 Table 9: Highway NLoS channel parameters 0 200 433 700 0 689
-492 886 The adjacent and non-adjacent channel rejection measurements are provided in Table 10 and Table 11 respectively. UBX-17004377 - R04 Confidential Electrical specification Page 16 of 28 VERA-P1 series - Data Sheet Bit rate Target ACR (dB) Target opt. enc. ACR (dB) VERA-P1 typical ACR (dB) 3 Mbps (1/2BPSK) 4.5 Mbps (3/4BPSK) 6 Mbps (1/2QPSK) 9 Mbps (3/4QPSK) 12 Mbps (1/2QAM16) 18 Mbps (3/4QAM16) 24 Mbps (2/3QAM64) 27 Mbps (3/4QAM64) 16 15 13 11 8 4 0
-1 Table 10: Adjacent channel rejection 28 27 25 23 20 16 12 11 37 33 35 29 29 25 22 20 Bit rate Target ACR (dB) Target opt. enc. ACR (dB) VERA-P1 typical ACR (dB) 42 41 39 37 34 30 26 25 51 48 48 45 42 38 34 32 3 Mbps (1/2BPSK) 4.5 Mbps (3/4BPSK) 6 Mbps (1/2QPSK) 9 Mbps (3/4QPSK) 12 Mbps (1/2QAM16) 18 Mbps (3/4QAM16) 24 Mbps (2/3QAM64) 27 Mbps (3/4QAM64) 32 31 29 27 24 20 16 15 Table 11: Non-adjacent channel rejection Channel Frequency, GHz 172 174 176 178 180 182 184 5.860 5.870 5.880 5.890 5.900 5.910 5.920 Table 12: Supported channels UBX-17004377 - R04 Confidential Electrical specification Page 17 of 28 VERA-P1 series - Data Sheet 5 Mechanical specifications 5.1 Physical dimensions Figure 4: Physical dimensions UBX-17004377 - R04 Confidential Mechanical specifications Page 18 of 28 Symbol Description A A1 b D D2 D3 E E2 E3 e E1 aaa ddd eee fff ggg Module Thickness Vertical distance from the solder mask to the pad surface Width of the peripheral pads Module horizontal dimension Horizontal dimension of the exposed thermal pads pattern Horizontal dimension of the individual exposed thermal pad Module vertical dimension Vertical dimension of the exposed thermal pads pattern Vertical dimension of the individual exposed thermal pad Pitch of the peripheral pads Pitch of the individual exposed thermal pads Bilateral profile tolerance of the module body Co-planarity of the module bottom surface (unilateral tolerance) Tolerance of the peripheral pads pattern position Tolerance of the peripheral pads position with respect to each other Tolerance of the exposed thermal pads pattern position Table 13: VERA-P1 series dimensional references VERA-P1 series - Data Sheet Min. 3.3 0.010 0.70 24.8 BSC 17.7 3.9 29.6 BSC 22.3 3.9 1.2 BSC 4.6 BSC Millimeters Nom. Max. 3.5 3.7 0.020 0.035 0.75 0.80 17.8 4.0 22.4 4.0 0.2 0.1 0.2 0.04 0.08 17.9 4.1 22.5 4.1 The aaa tolerances +/- 0.2 mm may be exceeded in the corners of the PCB due to the cutting process. In worst case, the outer dimension D could reach 25.1 mm. UBX-17004377 - R04 Confidential Mechanical specifications Page 19 of 28 VERA-P1 series - Data Sheet 6 Qualification and approvals 6.1 Approvals8 Products marked with this lead-free symbol on the product label comply with the
"Directive 2002/95/EC of the European Parliament and the Council on the Restriction of Use of certain Hazardous Substances in Electrical and Electronic Equipment" (RoHS). VERA-P1 series V2X modules are RoHS compliant. 6.1.1 European Union regulatory compliance TBD 6.1.2 FCC compliance The VERA-P173 module complies with Part 95, Subpart L of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Non authorized modification could void authority to use this equipment. The internal / external antenna(s) used for this module must provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. in accordance with the manufacturers These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used interference to radio communications. The outside of final product that contains the VERA-P173 module must display in a user accessible area a label referring to the enclosed module. This exterior label can use wording such as the following:
Contains Transmitter Module FCC ID: XPYVERAP173 or Contains FCC ID: XPYVERAP173. Part 95, Subpart L covers DSRC service of On-Board Units. VERA-P173 authorization for Road Side Units is pending. instructions, may cause harmful 6.1.3 IC compliance TBD 6.1.4 FCC and IC IDs Model VERA-P171 VERA-P173 VERA-P174 FCC ID tbd XPYVERAP173 tbd IC ID tbd tbd tbd Table 14: FCC and IC IDs for different models of VERA-P1 series 8 These approvals are pending. UBX-17004377 - R04 Confidential Qualification and approvals Page 20 of 28 VERA-P1 series - Data Sheet 6.1.5 Certification in other countries TBD 6.2 Approved antennas VERA-P173 is certified to be used with dipole antennas of up to 6 dBi peak gain. Table 15 below lists an example of an approved antenna. Model name TD.10.5113 Manufacturer and description Gain [dBi] (peak) Taoglas, Dipole Terminal Antenna SMA Connector 5.88 dBi Table 15: Approved antennas (example) UBX-17004377 - R04 Confidential Qualification and approvals Page 21 of 28 VERA-P1 series - Data Sheet 7 Product handling & soldering 7.1 Packaging The VERA-P1 series modules are delivered as hermetically sealed, reeled tapes to enable efficient production, production lot set-up and tear-down. For more information about packaging, see the u-blox Package Information Guide [1]. 7.1.1 Reels The VERA-P1 series modules are deliverable in quantities of 250 pieces on a reel. The VERA-P1 series modules are shipped on reel Type A as specified in the u-blox Package Information Guide [1]. 7.1.2 Tapes The dimensions of the tapes are specified in Figure 5. Figure 5: VERA-P1 tape dimensions 7.2 Shipment, storage and handling For more information regarding shipment, storage and handling see the u-blox Package Information Guide [1]. 7.2.1 Moisture sensitivity levels The VERA-P1 series modules are rated at moisture sensitivity level 3. See moisture sensitive warning label on each shipping bag for detailed information. After opening the dry pack, modules must be mounted within 168 hours in factory conditions of maximum 30 C/60%RH or must be stored at less than 10%RH. Modules require baking if the humidity indicator card shows more than 10% when read at 235C or if the conditions mentioned above are not met. Please refer to J-STD-033B standard for bake procedure. UBX-17004377 - R04 Confidential Product handling & soldering Page 22 of 28 VERA-P1 series - Data Sheet 7.2.2 Mounting process and soldering recommendations The VERA-P1 series module is a surface mount module supplied on an 8-layer FR4-type PCB with gold plated connection pins and produced in a lead-free process with a lead-free soldering paste. The wrap page of the PCB is max. 0,75% according to IPC-A-610E. The thickness of solder resist on the host PCB top side and the JODY-W1 bottom side must be considered for the soldering process. This module is compatible with industrial reflow profile for RoHS/Pb-free solders, Sn96.5/Ag3.0/Cu0.5 solder is a right choice. Use of "No Clean" soldering paste is strongly recommended, cleaning the populated modules is strongly discouraged - residuals under the module cannot be easily removed with any cleaning process. Cleaning with water can lead to capillary effects where water is absorbed into the gap between the host board and module. The combination of soldering flux residuals and encapsulated water could lead to short circuits between neighboring pins. Only a single reflow soldering process is permitted for host boards with the VERA-P1 series modules. The reflow profile used is dependent on the thermal mass of the entire populated PCB, heat transfer efficiency of the oven and particular type of solder paste used. Since the profile used is process and layout dependent, the optimum profile should be studied case by case. Recommendations below should be taken as a starting point guide. In case of basic information necessity, refer to J-STD-020C standard. Profile feature Ramp up rate (TSMAX to TP) Minimum soak temperature (TSMIN) Maximum soak temperature (TSMAX) Soak time (ts) Liquidus temperature (TL) Time above TL (tL) Peak temperature (TP) Sn-Pb eutectic
(Sn63/Pb37) 3 C/sec max 100 C 150 C 60 - 120 sec 183 C 60 - 150 sec 215 225 C Time within +0 / -5C of actual TP (tp) 10 - 30 sec Ramp down rate Time from 25C to TP 6 C/sec max 6 min max Table 16: Recommended reflow profile RoHS/Pb-free
(Sn96.5/Ag3.0/Cu0.5) 3 C/sec max 150 C 200 C 60 - 180 sec 217 C 60 - 150 sec 235 245 C 20 - 40 sec 6 C/sec max 8 min max The lowest value of TP and slower ramp down rate (2 3 C/sec) is preferred. Figure 6: Reflow profile UBX-17004377 - R04 Confidential Product handling & soldering Page 23 of 28 VERA-P1 series - Data Sheet 7.2.3 ESD handling precautions VERA-P1 series modules are Electrostatic Sensitive Devices (ESD). Observe precautions for handling! Failure to observe these precautions can result in severe damage to the Wi-Fi receiver!
Wi-Fi transceivers are Electrostatic Sensitive Devices (ESD) and require special precautions when handling. Particular care must be exercised when handling patch antennas, due to the risk of electrostatic charges. In addition to standard ESD safety practices, the following measures should be taken into account whenever handling the receiver:
Unless there is a galvanic coupling between the local GND (i.e. the work table) and the PCB GND, then the first point of contact when handling the PCB must always be between the local GND and PCB GND. Before mounting an antenna patch, connect ground of the device When handling the RF pin, do not come into contact with any charged capacitors and be careful when contacting materials that can develop charges (e.g. patch antenna ~10 pF, coax cable ~50-80 pF/m, soldering iron, ) To prevent electrostatic discharge through the RF input, do not touch any exposed antenna area. If there is any risk that such exposed antenna area is touched in non ESD protected work area, implement proper ESD protection measures in the design. When soldering RF connectors and patch antennas to the receivers RF pin, make sure to use an ESD safe soldering iron (tip). UBX-17004377 - R04 Confidential Product handling & soldering Page 24 of 28 VERA-P1 series - Data Sheet 8 Labeling and ordering information 8.1 Product labeling 8.2 Explanation of codes Three different product code formats are used. The Product Name is used in documentation such as this data sheet and identifies all u-blox products, independent of packaging and quality grade. The Ordering Code includes options and quality, while the Type Number includes the hardware and firmware versions. Table 17 below details these three different formats:
Format Product Name Ordering Code Type Number Structure PPPP-TGVV PPPP-TGVV-TTQ PPPP-TGVV-TTQ-XX Table 17: Product Code Formats Code Meaning PPPP TG VV TT Q Form factor Platform T Dominant technology, For example, W: Wi-Fi, B: Bluetooth G - Generation Variant based on the same platform; range [0099]
Major Product Version Quality grade A: Automotive B: Professional C: Standard XX Minor product version (not relevant for certification) Table 18: Part identification code 8.3 Ordering codes Example VERA P1 71 00 A 00 Ordering Code Product name Product VERA-P171-00A-00 VERA-P171 VERA-P171 automotive grade module VERA-P173-00A-00 VERA-P173 VERA-P173 automotive grade module VERA-P174-00A-00 VERA-P174 VERA-P174 automotive grade module EVK-VERA-P174-00A EVK-VERA-P174 VERA-P171/3/4 Evaluation kit Table 19: Product ordering codes Product changes affecting form, fit or function are documented by u-blox. For a list of Product Change Notifications (PCNs) see our website. UBX-17004377 - R04 Confidential Labeling and ordering information Page 25 of 28 VERA-P1 series - Data Sheet Appendix Glossary Name COTS CS ESD ETSI FCC GND GPIO IC LLC MAC nACR NLoS OBU OFDM PCB RF RSU RoHS SPI USB V2X Definition Commercial off-the-shelf Chip select Electrostatic Sensitive Devices European Telecommunications Standards Institute Federal Communications Commission Ground General-purpose input/output Industry Canada Logical Link Control Media Access Control Non-adjacent channel rejection Non-Line-of-Sight On Board Unit Orthogonal frequency-division multiplexing Printed Circuit Board Radio Frequency Road Side Unit Restriction of Hazardous Substances Serial Peripheral Interface Universal Serial Bus Vehicle-to-Everything Table 20: Explanation of abbreviations used UBX-17004377 - R04 Confidential Appendix Page 26 of 28 VERA-P1 series - Data Sheet Related documents
[1]
u-blox Package Information Guide, document number UBX-14001652 For regular updates to u-blox documentation and to receive product change notifications, register on our homepage (http://www.u-blox.com). Revision history Revision Date Name Comments R01 R02 23-Feb-2017 ishe, kgom Initial release. 5-May-2017 ddie, kgom Added VERA-P174 product variant and included block diagram, FCC/IC ID, and ordering code for this variant. R03 11-Sep-2017 mzes, kgom, ddie Updated Table 1. Included footnotes in section 1.5. Updated the ordering codes (section 8.3). Added reel size (section 7.1) and tape dimensions (Figure 5). R04 7-Dec-2017 ddie, kgom Removed references to VERA-P175 variant. Updated Table 1. Added section 6.1.2 on FCC compliance. Removed watermark. Clarified that RSU operation is not approved (Section 1.1). Updated maximum transmit power (Section 4.6). UBX-17004377 - R04 Confidential Related documents Page 27 of 28 Contact For complete contact information visit us at www.u-blox.com. u-blox Offices North, Central and South America u-blox America, Inc. Phone:
E-mail:
+1 703 483 3180 info_us@u-blox.com Regional Office West Coast:
Phone:
E-mail:
+1 408 573 3640 info_us@u-blox.com Technical Support:
Phone:
E-mail:
+1 703 483 3185
.support@u-blox.com Headquarters Europe, Middle East, Africa u-blox AG Phone:
E-mail:
Support:
+41 44 722 74 44 info@u-blox.com support@u-blox.com Documentation Feedback E-mail:
docsupport@u-blox.com VERA-P1 series - Data Sheet Asia, Australia, Pacific u-blox Singapore Pte. Ltd. Phone:
E-mail:
Support:
+65 6734 3811 info_ap@u-blox.com support_ap@u-blox.com Regional Office Australia:
Phone:
E-mail:
Support:
+61 2 8448 2016 info_anz@u-blox.com support_ap@u-blox.com Regional Office China (Beijing):
Phone:
E-mail:
Support:
+86 10 68 133 545 info_cn@u-blox.com support_cn@u-blox.com Regional Office China (Chongqing):
Phone:
E-mail:
Support:
+86 23 6815 1588 info_cn@u-blox.com support_cn@u-blox.com Regional Office China (Shanghai):
Phone:
E-mail:
Support:
+86 21 6090 4832 info_cn@u-blox.com support_cn@u-blox.com Regional Office China (Shenzhen):
Phone:
E-mail:
Support:
+86 755 8627 1083 info_cn@u-blox.com support_cn@u-blox.com Regional Office India:
Phone:
E-mail:
Support:
+91 80 4050 9200 info_in@u-blox.com support_in@u-blox.com Regional Office Japan (Osaka):
Phone:
E-mail:
Support:
+81 6 6941 3660 info_jp@u-blox.com support_jp@u-blox.com Regional Office Japan (Tokyo):
Phone:
E-mail:
Support:
+81 3 5775 3850 info_jp@u-blox.com support_jp@u-blox.com Regional Office Korea:
Phone:
E-mail:
Support:
+82 2 542 0861 info_kr@u-blox.com support_kr@u-blox.com Regional Office Taiwan:
Phone:
E-mail:
Support:
+886 2 2657 1090 info_tw@u-blox.com support_tw@u-blox.com UBX-17004377 - R04 Confidential Contact Page 28 of 28
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2018-01-17 | 5860 ~ 5920 | TNB - Licensed Non-Broadcast Station Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2018-01-17
|
||||
1 | Applicant's complete, legal business name |
u-blox AG
|
||||
1 | FCC Registration Number (FRN) |
0019077858
|
||||
1 | Physical Address |
Zuercherstrasse 68
|
||||
1 |
Thalwil, N/A Ch-8800
|
|||||
1 |
Switzerland
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
h******@acbcert.com
|
||||
1 | TCB Scope |
B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
XPY
|
||||
1 | Equipment Product Code |
VERAP173
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
G**** C********
|
||||
1 | Title |
Certification Manager
|
||||
1 | Telephone Number |
+3904********
|
||||
1 | Fax Number |
+3904********
|
||||
1 |
g******@u-blox.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | TNB - Licensed Non-Broadcast Station Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | IEEE 802.11p module for OBU units | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Single Modular Approval | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Output power listed is conducted. This module is certified for DSRCS operation in on-board use only. It is certified for mobile use where the transmitter antenna is more than 20 cm from all persons. Co-location with other transmitters requires the use of FCC multi-transmitter product procedures. This module must only be used with a host antenna circuit trace layout design in strict compliance with the installation instructions provided. Installers must be provided with installation and operation instructions for satisfying RF Exposure compliance. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
7layers GmbH
|
||||
1 | Name |
B**** R******
|
||||
1 | Telephone Number |
0049 ********
|
||||
1 | Fax Number |
0049 ********
|
||||
1 |
B******@7layers.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 95L | 5860.00000000 | 5920.00000000 | 0.1349000 | 1.5000000000 ppm | 8M01D1D |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC