all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
[short-term confidential] User's Manual | Users Manual | 2.23 MiB | ||||
1 | Cover Letter(s) | |||||||
1 | Test Report | |||||||
1 | Attestation Statements | |||||||
1 | Cover Letter(s) | |||||||
1 | Cover Letter(s) | |||||||
1 | ID Label/Location Info | |||||||
1 | RF Exposure Info | |||||||
1 | External Photos | |||||||
1 | External Photos | |||||||
1 | Internal Photos | |||||||
1 | Test Setup Photos |
1 | [short-term confidential] User's Manual | Users Manual | 2.23 MiB |
l e t a r e e c c a
, e t a c n u m m o c
, e t a c o i l 33.2 x 22.4 x 2.7 mm LISA-U1/LISA-H1 series 3.75G/3.5G HSxPA Wireless Modules System Integration Manual Abstract This document describes the features and the integration of the LISA-U1/LISA-H1 series HSxPA wireless modules. LISA-U1/LISA-H1 series modules are a complete and cost efficient 3.75G/3.5G solution offering high-speed dual-band HSDPA/HSUPA and quad-band GSM/GPRS voice and/or data transmission technology in a compact form factor. www.u-blox.com LISA-U1/LISA-H1 series - System Integration Manual Document Information Title Subtitle LISA-U1/LISA-H1 series 3.75G/3.5G HSxPA Wireless Modules Document type System Integration Manual Document number 3G.G2-HW-10002-2 Document status Advance Information Document status information Objective Specification This document contains target values. Revised and supplementary data will be published later. Advance Information Preliminary This document contains data based on early testing. Revised and supplementary data will be published later. This document contains data from product verification. Revised and supplementary data may be published later. Released This document contains the final product specification. This document applies to the following products:
Name Type number Firmware version PCN / IN LISA-U100 LISA-U100-00S-00 LISA-U110 LISA-U110-00S-00 LISA-U120 LISA-U120-00S-00 LISA-U130 LISA-U130-00S-00 LISA-H100 LISA-H100-00S-00 LISA-H110 LISA-H110-00S-00 n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. This document and the use of any information contained therein, is subject to the acceptance of the u-blox terms and conditions. They can be downloaded from www.u-blox.com. u-blox makes no warranties based on the accuracy or completeness of the contents of this document and reserves the right to make changes to specifications and product descriptions at any time without notice. u-blox reserves all rights to this document and the information contained herein. Reproduction, use or disclosure to third parties without express permission is strictly prohibited. Copyright 2011, u-blox AG. u-blox is a registered trademark of u-blox Holding AG in the EU and other countries. 3G.G2-HW-10002-2 Page 2 of 116 LISA-U1/LISA-H1 series - System Integration Manual Preface u-blox Technical Documentation As part of our commitment to customer support, u-blox maintains an extensive volume of technical documentation for our products. In addition to our product-specific technical data sheets, the following manuals are available to assist u-blox customers in product design and development. AT Commands Manual: This document provides the description of the supported AT commands by the LISA-U1/LISA-H1 series module to verify all implemented functionalities. System Integration Manual: This Manual provides hardware design instructions and information on how to set up production and final product tests. Application Note: document provides general design instructions and information that applies to all u-blox Wireless modules. See Section Related documents for a list of Application Notes related to your Wireless Module. How to use this Manual The LISA-U1/LISA-H1 series System Integration Manual provides the necessary information to successfully design in and configure these u-blox wireless modules. This manual has a modular structure. It is not necessary to read it from the beginning to the end. The following symbols are used to highlight important information within the manual:
An index finger points out key information pertaining to module integration and performance. A warning symbol indicates actions that could negatively impact or damage the module. Questions If you have any questions about u-blox Wireless Integration, please:
Read this manual carefully. Contact our information service on the homepage http://www.u-blox.com Read the questions and answers on our FAQ database on the homepage http://www.u-blox.com Technical Support Worldwide Web Our website (www.u-blox.com) is a rich pool of information. Product information, technical documents and helpful FAQ can be accessed 24h a day. By E-mail Contact the nearest of the Technical Support offices by email. Use our service pool email addresses rather than any personal email address of our staff. This makes sure that your request is processed as soon as possible. You will find the contact details at the end of the document. Helpful Information when Contacting Technical Support When contacting Technical Support please have the following information ready:
Module type (e.g. LISA-U100) and firmware version Module configuration Clear description of your question or the problem A short description of the application Your complete contact details 3G.G2-HW-10002-2 Advance Information Preface Page 3 of 116 LISA-U1/LISA-H1 series - System Integration Manual Contents Preface ................................................................................................................................ 3 Contents .............................................................................................................................. 4 1.6 1.7 1.8 1.2.1 1.2.2 1 System description ....................................................................................................... 7 1.1 Overview .............................................................................................................................................. 7 1.2 Architecture .......................................................................................................................................... 8 Functional blocks ........................................................................................................................... 9 Hardware differences between LISA-U1/LISA-H1 series modules .................................................. 10 Pin-out ............................................................................................................................................... 11 1.3 1.4 Operating modes ................................................................................................................................ 14 Power management ........................................................................................................................... 16 1.5 Power supply circuit overview ...................................................................................................... 16 1.5.1 1.5.2 Module supply (VCC) .................................................................................................................. 17 Current consumption profiles ...................................................................................................... 24 1.5.3 RTC Supply (V_BCKP) .................................................................................................................. 28 1.5.4 1.5.5 Interface supply (V_INT) ............................................................................................................... 30 System functions ................................................................................................................................ 31 1.6.1 Module power on ....................................................................................................................... 31 1.6.2 Module power off ....................................................................................................................... 35 1.6.3 Module reset ............................................................................................................................... 36 RF connection ..................................................................................................................................... 37
(U)SIM interface .................................................................................................................................. 38
(U)SIM functionality ..................................................................................................................... 40 Serial communication ......................................................................................................................... 41 Serial interfaces configuration ..................................................................................................... 41 1.9.1 Asynchronous serial interface (UART)........................................................................................... 42 1.9.2 USB interface............................................................................................................................... 54 1.9.3 1.9.4 SPI interface ................................................................................................................................ 56 1.9.5 MUX Protocol (3GPP 27.010) ...................................................................................................... 60 DDC (I2C) interface .......................................................................................................................... 61 1.10.1 Overview ..................................................................................................................................... 61 1.10.2 DDC application circuit ................................................................................................................ 62 Audio Interface (LISA-U120 and LISA-U130 only) ............................................................................ 63 1.11.1 Analog Audio interface ............................................................................................................... 64 1.11.2 Digital Audio interface ................................................................................................................. 70 1.11.3 Voiceband processing system ...................................................................................................... 72 General Purpose Input/Output (GPIO) ............................................................................................. 74 Reserved pins (RSVD) ...................................................................................................................... 77 Schematic for LISA-U1/LISA-H1 series module integration ............................................................... 78 Approvals ........................................................................................................................................ 79 1.12 1.13 1.14 1.15 1.8.1 1.10 1.11 1.9 3G.G2-HW-10002-2 Advance Information Contents Page 4 of 116 LISA-U1/LISA-H1 series - System Integration Manual 1.15.1 R&TTED and European Conformance CE mark ............................................................................ 79 IC ................................................................................................................................................ 79 1.15.2 1.15.3 Federal communications commission notice ................................................................................ 79 2.2 2.1 2.2.1 2.2.2 2.2.3 2.1.1 2.1.2 2.1.3 2 Design-In ..................................................................................................................... 82 Design-in checklist .............................................................................................................................. 82 Schematic checklist ..................................................................................................................... 82 Layout checklist ........................................................................................................................... 82 Antenna checklist ........................................................................................................................ 83 Design Guidelines for Layout .............................................................................................................. 84 Layout guidelines per pin function ............................................................................................... 84 Footprint and paste mask ............................................................................................................ 93 Placement ................................................................................................................................... 94 Thermal aspects .................................................................................................................................. 95 Antenna guidelines ............................................................................................................................. 96 Antenna termination ................................................................................................................... 97 Antenna radiation ....................................................................................................................... 98 Antenna detection functionality .................................................................................................. 99 ESD immunity test precautions ......................................................................................................... 102 General precautions .................................................................................................................. 102 2.5.1 2.5.2 Antenna interface precautions ................................................................................................... 103 2.5.3 Module interfaces precautions ................................................................................................... 104 2.4.1 2.4.2 2.4.3 2.3 2.4 2.5 3.1 3.2 3 Handling and soldering ........................................................................................... 105 Packaging, shipping, storage and moisture preconditioning ............................................................. 105 Soldering .......................................................................................................................................... 105 Soldering paste.......................................................................................................................... 105 3.2.1 Reflow soldering ....................................................................................................................... 105 3.2.2 Optical inspection ...................................................................................................................... 107 3.2.3 Cleaning .................................................................................................................................... 107 3.2.4 3.2.5 Repeated reflow soldering ......................................................................................................... 107 3.2.6 Wave soldering.......................................................................................................................... 107 3.2.7 Hand soldering .......................................................................................................................... 107 Rework ...................................................................................................................................... 107 3.2.8 3.2.9 Conformal coating .................................................................................................................... 107 3.2.10 Casting ...................................................................................................................................... 108 3.2.11 Grounding metal covers ............................................................................................................ 108 3.2.12 Use of ultrasonic processes ........................................................................................................ 108 4 Product Testing......................................................................................................... 109 u-blox in-series production test ......................................................................................................... 109 Test parameters for OEM manufacturer ............................................................................................ 109 4.1 4.2 Appendix ........................................................................................................................ 110 3G.G2-HW-10002-2 Advance Information Contents Page 5 of 116 LISA-U1/LISA-H1 series - System Integration Manual A.1 A Extra Features ........................................................................................................... 110 TCP/IP ............................................................................................................................................... 110 A.1.1 Multiple IP addresses and sockets .............................................................................................. 110 FTP ................................................................................................................................................... 110 A.2 A.3 FTPS ................................................................................................................................................. 110 A.4 HTTP ................................................................................................................................................. 110 A.5 HTTPS ............................................................................................................................................... 110 A.6 SMTP ................................................................................................................................................ 110 A.7 AssistNow clients and GPS integration .............................................................................................. 110 In-Band modem (LISA-U130 only) ..................................................................................................... 110 A.8 A.9 Smart temperature supervision ......................................................................................................... 111 B Glossary .................................................................................................................... 112 Related documents......................................................................................................... 114 Revision history .............................................................................................................. 114 Contact ............................................................................................................................ 116 3G.G2-HW-10002-2 Advance Information Contents Page 6 of 116 LISA-U1/LISA-H1 series - System Integration Manual 1 System description 1.1 Overview The LISA-U1/LISA-H1 series is a family of SMT wireless modules featuring Leadless Chip Carrier (LCC) packaging and integrating a full-feature 3G UMTS/HSxPA and 2G GSM/GPRS/EDGE protocol stack with A-GPS support. UMTS/HSDPA/HSUPA characteristics:
UMTS Terrestrial Radio Access (UTRA) Frequency Division Duplex (FDD) operating mode Dual-band support:
Band II (1900 MHz) and Band V (850 MHz) for LISA-U100, LISA-U120, LISA-H100 Band I (2100 MHz) and Band VIII (900 MHz) for LISA-U110, LISA-U130, LISA-H110 Power Class 3 (24 dBm) for WCDMA/HSDPA/HSUPA mode HSUPA category 6, up to 7.2 Mb/s DL, 5.76 Mb/s UL (LISA-U1 series only) HSDPA category 8, up to 7.2 Mb/s DL, 384 kb/s UL (LISA-U1 series only) HSDPA category 6, up to 3.6 Mb/s DL, 384 kb/s UL (LISA-H1 series only) WCDMA PS data up to 384 kb/s DL/UL WCDMA CS data up to 64 kb/s DL/UL GSM/GPRS/EDGE characteristics:
Quad-band support: GSM 850 MHz, E-GSM 900 MHz, DCS 1800 MHz and PCS 1900 MHz GSM/GPRS Power Class 4 (33 dBm) for GSM/E-GSM bands GSM/GPRS Power Class 1 (30 dBm) for DCS/PCS bands EDGE Power Class E2 (27 dBm) for GSM/E-GSM bands EDGE Power Class E2 (26 dBm) for DCS/PCS bands EDGE multislot class 121, coding scheme MCS1-MCS9, up to 236.8 kb/s GPRS multislot class 121, coding scheme CS1-CS4, up to 85.6 kb/s CSD Non-transparent / Transparent Mode, up to 9.6 kb/s As a 3G module the LISA-U1/LISA-H1 series module is Class A User Equipment: the device can work simultaneously in Packet Switch and Circuit Switch mode. This means that voice calls are possible while the data connection is active without any interruption in service. As a 2G module the LISA-U1/LISA-H1 series module is Class B Mobile Station: the device can be attached to both GPRS and GSM services (i.e. Packet Switch and Circuit Switch mode), using one service at a time. For instance, if during data transmission an incoming call occurs, the data connection is suspended to permit the voice communication. Once the voice call has terminated, the data service is resumed. Network operation modes I to III are supported, with user-definable preferred service selectable from GSM to GPRS. Optionally paging messages for GSM calls can be monitored during GPRS data transfer in not-coordinating NOM II-III. LISA-U1/LISA-H1 series modules implement GPRS/EGPRS class 12 for data transfer. GPRS class determines the number of timeslots available for upload and download and thus the speed at which data can be transmitted and received, with higher classes typically allowing faster data transfer rates. Class 12 implies a maximum of 4 slots in download (reception) and 4 slots in upload (transmission) with 5 slots in total. The network automatically configures the number of timeslots used for reception or transmission (voice calls take precedence over GPRS traffic). The network also automatically configures channel encoding (CS1 to MCS9). The maximum (E)GPRS bit rate of the mobile station depends on the coding scheme and number of time slots. Direct Link mode is supported for TCP sockets. 1 GPRS/EDGE multislot class 12 implies a maximum of 4 slots in DL (reception) and 4 slots in UL (transmission) with 5 slots in total. 3G.G2-HW-10002-2 Advance Information System description Page 7 of 116 LISA-U1/LISA-H1 series - System Integration Manual 1.2 Architecture Figure 1: LISA-U100, LISA-U110, LISA-H100, LISA-H110 block diagram Figure 2: LISA-U120, LISA-U130 block diagram 3G.G2-HW-10002-2 Advance Information System description Page 8 of 116 WirelessBase-bandProcessorMemoryPower Management UnitRF Transceiver26 MHz32.768 kHzSAWFilterFEM & 2G PAANTLNA3G PALNA3G PADDC (for GPS)(U)SIM CardUARTSPIUSBGPIO(s)Power OnExternal ResetV_BCKP (RTC)Vcc (Supply)V_INT (I/O)WirelessBase-bandProcessorMemoryPower Management UnitRF Transceiver26 MHz32.768 kHzSAWFilterFEM & 2G PAANTLNA3G PALNA3G PADDC (for GPS)(U)SIM CardUARTSPIUSBGPIO(s)Power OnExternal ResetV_BCKP (RTC)Vcc (Supply)V_INT (I/O)Digital Audio (I2S)AnalogAudio LISA-U1/LISA-H1 series - System Integration Manual 1.2.1 Functional blocks LISA-U1/LISA-H1 series modules consist of the following internal functional blocks: RF high power front-end, RF transceiver, Baseband section and Power Management Unit. RF high-power front-end A separated shielding box includes the RF high-power signal circuitry, namely:
Front-End Module (FEM) with integrated quad-band 2G Power Amplifier and antenna switch multiplexer Two single-band 3G HSxPA/WCDMA Power Amplifier modules with integrated duplexers The RF antenna is directly connected to the FEM, which dispatches the RF signals according to the active mode. For time-duplex 2G operation, the incoming signal at the active Receiver (RX) slot is applied to integrated SAW filters for out-of-band rejection and then sent to the appropriate receiver port of the RF transceiver. During the allocated Transmitter (TX) slots, the low level signal coming from the RF transceiver is enhanced by the 2G power amplifier module and then directed to the antenna through the FEM. The 3G transmitter and receiver are instead active at the same time due to frequency-domain duplex operation. The switch integrated in the FEM connects the antenna port to the passive duplexer which separates the TX and RX signal paths. The duplexer itself provides front-end RF filtering for RX band selection while combining the amplified TX signal coming from the fixed gain linear power amplifier. RF Transceiver In the same shielding box that includes the RF high-power signal circuitry there are all the low-level analog RF components, namely:
Dual-band HSxPA/WCDMA and quad-band EDGE/GPRS/GSM transceiver Voltage Controlled Temperature Compensated 26 MHz Crystal Oscillator (VC-TCXO) Low Noise Amplifier (LNA) and SAW RF filters for 2G and 3G receivers While operating in 3G mode, the RF transceiver performs direct up-conversion and down-conversion of the baseband I/Q signals, with the RF voltage controlled gain amplifier being used to set the uplink TX power. In the downlink path, the external LNA enhances the RX sensitivity while discrete inter-stage SAW filters additionally improve the rejection of out-of-band blockers. An internal programmable gain amplifier optimizes the signal levels before delivering to the analog I/Q to baseband for further digital processing. For 2G operations, a constant gain direct conversion receiver with integrated LNAs and highly linear RF quadrature demodulator are used to provide the same I/Q signals to baseband as well. In transmit mode, the up-conversion is implemented by means of a digital sigma-delta transmitter or polar modulator depending on the modulation to be transmitted. In all the modes, a fractional-N sigma-delta RF synthesizer and an on-chip 3.8-4 GHz voltage controlled oscillator are used to generate the local oscillator signal. The frequency reference to RF oscillators is provided by the 26 MHz VC-TCXO. The same signal is buffered to the baseband as a master reference for clock generation circuits while operating in active mode. Modulation Types Used GSM GSMK GPRS GMSK EDGE 8PSK WCDMA QPSK HSDPA 16-QAM HSUPA BPSK Baseband section and power management unit Another shielding box includes all the digital circuitry and the power supplies, basically the following functional blocks:
3G.G2-HW-10002-2 Advance Information System description Page 9 of 116 LISA-U1/LISA-H1 series - System Integration Manual Wireless baseband processor, a mixed signal ASIC which integrates:
Microprocessor for controller functions, 2G & 3G upper layer software DSP core for 2G Layer 1 and audio processing 3G coprocessor and HW accelerator for 3G Layer 1 control software and routines Dedicated HW for peripherals control, as UART, USB, SPI etc Memory system in a Multi-Chip Package (MCP) integrating two devices:
NOR flash non-volatile memory DDR SRAM volatile memory Power Management Unit (PMU), used to derive all the system supply voltages from the module supply VCC 32.768 kHz crystal, connected to the Real Time Clock (RTC) oscillator to provide the clock reference in idle or power off mode 1.2.2 Hardware differences between LISA-U1/LISA-H1 series modules Hardware differences between the LISA-U1/LISA-H1 series modules:
3G Dual-band support:
Band II (1900 MHz) and Band V (850 MHz) are supported by LISA-U100, LISA-U120, LISA-H100 Band I (2100 MHz) and Band VIII (900 MHz) are supported by LISA-U110, LISA-U130, LISA-H110 3G maximum data rate capabilities:
HSUPA category 6, up to 7.2 Mb/s DL, 5.76 Mb/s UL for LISA-U1 series HSDPA category 8, up to 7.2 Mb/s DL, 384 kb/s UL for LISA-U1 series HSDPA category 6, up to 3.6 Mb/s DL, 384 kb/s UL for LISA-H1 series Audio support:
One differential analog audio input, one differential analog audio output and one 4-wire digital audio interface are supported by LISA-U120 and LISA-U130 No analog audio input, no analog audio output and no digital audio interface are supported by LISA-U100, LISA-U110, LISA-H100, LISA-H110 3G.G2-HW-10002-2 Advance Information System description Page 10 of 116 LISA-U1/LISA-H1 series - System Integration Manual 1.3 Pin-out Table 1 lists the pin-out of the LISA-U1/LISA-H1 series modules, with pins grouped by function. Function Power Pin VCC No I/O Description Remarks 61, 62, 63 I Module Supply Clean and stable supply is required: low ripple and low voltage drop must be guaranteed. Voltage provided has to be always above the minimum limit of the operating range. Consider that there are large current spikes in connected mode, when a GSM call is enabled. VCC pins are internally connected, but all the available pads must be connected to the external supply in order to minimize power loss due to series resistance. See section 1.5.2 GND pins are internally connected but a good
(low impedance) external ground connection can improve RF performance: all GND pins must be externally connected to ground. V_BCKP = 2.3 V (typical) generated by the module when VCC supply voltage is within valid operating range. See section 1.5.4 V_INT = 1.8V (typical) generated by the module when it is switched-on and the RESET_N (external reset input pin) is not forced to the low level. See section 1.5.5 VSIM = 1.80 V typical or 2.90 V typical generated by the module according to the SIM card type. See section 1.8 50 nominal impedance. See section 1.7, section 2.4 and section 2.2.1.1 Internal 4.7 k pull-up to VSIM. Must meet SIM specifications. See section 1.8 Must meet SIM specifications. See section 1.8 Must meet SIM specifications. See section 1.8 Module Output: module runs as an SPI slave. See section 1.9.4 Module Input: module runs as an SPI slave. Internal active pull-up to V_INT (1.8 V) enabled. See section 1.9.4 Module Input: module runs as an SPI slave. Internal active pull-down to GND enabled. See section 1.9.4 Module Output: module runs as an SPI slave. See section 1.9.4 N/A Ground GND 1, 3, 6, 7, 8, 17, 25, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 60, 64, 65, 66, 67, 69, 70, 71, 72, 73, 75, 76 V_BCKP 2 I/O Real Time Clock supply input/output V_INT 4 O Digital I/O Interfaces supply output RF SIM VSIM ANT SIM_IO SIM_CLK SIM_RST SPI SPI_MISO 50 68 48 47 49 57 SPI_MOSI 56 SPI_SCLK 55 SPI_SRDY 58 O O SIM supply output I/O RF antenna interface I/O SIM data O O O I I SIM clock SIM reset SPI Data Line. Master Input, Slave Output SPI Data Line. Master Output, Slave Input SPI Serial Clock. Master Output, Slave Input SPI Slave Ready to transfer control line. Master Input, Slave Output 3G.G2-HW-10002-2 Advance Information System description Page 11 of 116 LISA-U1/LISA-H1 series - System Integration Manual I/O Description Remarks Function Pin SPI_MRDY DDC UART SCL SDA RxD No 59 45 46 16 I O SPI Master Ready to transfer control line. Master Output, Slave Input I2C bus clock line I/O I2C bus data line O UART received data TxD 15 I UART transmitted data CTS 14 O UART clear to send RTS 13 I UART ready to send DSR RI DTR DCD GPIO1 GPIO2 GPIO3 GPIO4 GPIO5 GPIO USB VUSB_DET 9 10 12 11 20 21 23 24 51 18 O O I UART data set ready UART ring indicator UART data terminal ready I/O I/O I/O I/O I/O I GPIO GPIO GPIO GPIO GPIO USB detect input USB_D+
26 I/O USB Data Line D+
Module Input: module runs as an SPI slave. Internal active pull- down to GND enabled. See section 1.9.4 Fixed open drain. External pull-up required. See section 1.10 Fixed open drain. External pull-up required. See section 1.10 Circuit 104 (RxD) in ITU-T V.24. Provide access to the pin for FW update and debugging if the USB interface is connected to the application processor. See section 1.9.2 Circuit 103 (TxD) in ITU-T V.24. Internal active pull-up to V_INT (1.8 V) enabled. Provide access to the pin for FW update and debugging if the USB interface is connected to the application processor. See section 1.9.2 Circuit 106 (CTS) in ITU-T V.24. Provide access to the pin for debugging if the USB interface is connected to the application processor. See section 1.9.2 Circuit 105 (RTS) in ITU-T V.24. Internal active pull-up to V_INT (1.8 V) enabled. Provide access to the pin for debugging if the USB interface is connected to the application processor. See section 1.9.2 Circuit 107 (DSR) in ITU-T V.24. See section 1.9.2 Circuit 125 (RI) in ITU-T V.24. See section 1.9.2 Circuit 108/2 (DTR) in ITU-T V.24. Internal active pull-up to V_INT (1.8 V) enabled. See section 1.9.2 See section 1.9.2 See section 1.12 See section 1.12 See section 1.12 See section 1.12 See section 1.12 Input for VBUS (5 V typical) USB supply sense to enable USB interface. Provide access to the pin for FW update and debugging if the USB interface is not connected to the application processor. See section 1.9.3 90 nominal differential impedance Pull-up or pull-down resistors and external series resistors as required by the USB 2.0 high-speed specification [7] are part of the USB pad driver and need not be provided externally. Provide access to the pin for FW update and debugging if the USB interface is not connected to the application processor. See section 1.9.3 O UART data carrier detect Circuit 109 (DCD) in ITU-T V.24. 3G.G2-HW-10002-2 Advance Information System description Page 12 of 116 LISA-U1/LISA-H1 series - System Integration Manual Function Pin USB_D-
No 27 I/O I/O USB Data Line D-
Description Remarks 90 nominal differential impedance Pull-up or pull-down resistors and external series resistors as required by the USB 2.0 high-speed specification [7] are part of the USB pad driver and need not be provided externally. Provide access to the pin for FW update and debugging if the USB interface is not connected to the application processor. See section 1.9.3 PWR_ON pin has high input impedance. Do not keep floating in noisy environment:
external pull-up required. See section 1.6.1 Internal 10 k pull-up to V_BCKP (2.3 V). See section 1.6.3 Check device specifications to ensure compatibility to module supported modes. See section 1.11.2. Internal active pull-up to V_INT (1.8 V) enabled. Check device specifications to ensure compatibility to module supported modes. See section 1.11.2. Check device specifications to ensure compatibility to module supported modes. See section 1.11.2. Check device specifications to ensure compatibility to module supported modes. See section 1.11.2. Differential analog input shared for all analog path modes: handset, headset, hands-free mode. Internal DC blocking capacitor. See section 1.11.1 Differential analog input shared for all analog path modes: handset, headset, hands-free mode. Internal DC blocking capacitor. See section 1.11.1 Differential analog audio output shared for all analog path modes: earpiece, headset and loudspeaker mode. See section 1.11.1 Differential analog audio output shared for all analog path modes: earpiece, headset and loudspeaker mode. See section 1.11.1 This pin must be connected to ground Do not connect Do not connect Do not connect Do not connect Do not connect Do not connect Do not connect Do not connect Do not connect Do not connect System PWR_ON 19 RESET_N I2S_CLK 22 43 Audio
(LISA-U120, LISA-U130) I I Power-on input External reset input O I2S clock I2S_RXD 44 I I2S receive data I2S_TXD 42 O I2S transmit data I2S_WA 41 O I2S word alignment MIC_N 39 MIC_P 40 SPK_P 53 SPK_N 54 Reserved Reserved
(LISA-U100, LISA-U110, LISA-H100, LISA-H110) RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD 5 52 74 43 44 42 41 39 40 53 54 I I O O N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Differential analog audio input (negative) Differential analog audio input (positive) Differential analog audio output (positive) Differential analog audio output (negative) RESERVED pin RESERVED pin RESERVED pin RESERVED pin RESERVED pin RESERVED pin RESERVED pin RESERVED pin RESERVED pin RESERVED pin RESERVED pin Table 1: LISA-U1/LISA-H1 series modules pin-out 3G.G2-HW-10002-2 Advance Information System description Page 13 of 116 LISA-U1/LISA-H1 series - System Integration Manual 1.4 Operating modes LISA-U1/LISA-H1 series modules include several operating modes, each have different active features and interfaces. Table 2 summarizes the various operating modes and provides general guidelines for operation. Operating Mode Description Features / Remarks Transition condition General Status: Power-down Not-Powered Mode VCC supply not present or below operating range. Microprocessor switched off
(not operating). RTC only operates if supplied through V_BCKP pin. Power-Off Mode VCC supply within operating range. Microprocessor switched off
(not operating). Only RTC runs. General Status: Normal Operation Idle-Mode Microprocessor runs with 32 kHz as reference oscillator. Module does not accept data signals from an external device. Module is switched off. Application interfaces are not accessible. Internal RTC timer operates only if a valid voltage is applied to V_BCKP pin. Module cannot be switched on by a falling edge provided on the PWR_ON input, or by a preset RTC alarm or by a rising edge provided on the RESET_N input. Module is switched off: normal shutdown after sending the AT+CPWROFF command (refer to u-blox AT Commands Manual [2]). Application interfaces are not accessible. Only the internal RTC timer in operation. If power saving is enabled, the module automatically enters idle mode whenever possible. Application interfaces are disabled. If hardware flow control is enabled, the CTS line indicates that the module is in active mode and the UART interface is enabled: the line is driven in the OFF state when the module is not prepared to accept data by the UART interface. If hardware flow control is disabled, the CTS line is fixed to ON state. Module by default is not set to automatically enter idle mode whenever possible, unless power saving configuration is enabled by appropriate AT command (refer to u-blox AT Commands Manual [2], AT+UPSV). Module can be switched on by a falling edge on the PWR_ON input, or by a rising edge on the RESET_N input, or by a preset RTC alarm. If the module is registered with the network and power saving is enabled, it automatically enters idle mode and periodically wakes up to active mode to monitor the paging channel for the paging block reception according to network indication. If module is not registered with the network and power saving is enabled, it automatically enters idle mode and periodically wakes up to monitor external activity. Module wakes up from idle mode to active mode if a voice or data call incoming. Module wakes up from idle mode to active mode if an RTC alarm occurs. Module wakes up from idle mode to active mode when data is received on UART interface (refer to 1.9.2). Module wakes up from idle mode to active mode when the RTS input line is set to the ON state by the DTE if the AT+UPSV=2 command is sent to the module (refer to 1.9.2). Module wakes up from idle mode to active mode at USB detection, applying 5 V (typ.) to the VUSB_DET pin. Module wakes up from idle mode to active mode when the connected USB host forces a remote wakeup of the module as USB device (refer to 1.9.3). Module wakes up from idle mode to active mode when the connected SPI master indicates to the module that it is ready to transmit or receive, by the IPC SPI_MRDY signal (refer to 1.9.4). 3G.G2-HW-10002-2 Advance Information System description Page 14 of 116 LISA-U1/LISA-H1 series - System Integration Manual Operating Mode Description Features / Remarks Transition condition Module is switched on and is fully active. Power saving is not enabled by default: it can be enabled by the AT+UPSV command (see u-blox AT Commands Manual [2]) The application interfaces are enabled. The module is switched on and a voice call or a data call (2G/3G) is in progress. Module is fully active. The application interfaces are enabled. If power saving is enabled, the module automatically enters idle mode whenever possible (refer to u-blox AT Commands Manual [2], AT+UPSV). When call terminates, the module returns to the last operating state (Idle or Active). Active-Mode Microprocessor runs with 26 MHz as reference oscillator. The module is prepared to accept data signals from an external device. Connected-Mode Voice or data call enabled. Microprocessor runs with 26 MHz as reference oscillator. The module is prepared to accept data signals from an external device. Table 2: Module operating modes summary Transition between the different modes is described in Figure 3. Figure 3: Operating modes transition 3G.G2-HW-10002-2 Advance Information System description Page 15 of 116 Switch ON:Apply VCCIf power saving is enabled and there is no activity for a defined time intervalAny wake up event described in the module operating modes summary table aboveAT+CPWROFF(no HW pin)Incoming/outgoing call or other dedicated device network communicationCall terminated, communication droppedRemove VCCSwitch ON:PWR_ONRESET_NRTC AlarmNot poweredPower offActiveConnectedIdle LISA-U1/LISA-H1 series - System Integration Manual 1.5 Power management 1.5.1 Power supply circuit overview LISA-U1/LISA-H1 series modules feature a power management concept optimized for the most efficient use of supplied power. This is achieved by hardware design utilizing a power efficient circuit topology (Figure 4), and by power management software controlling the modules power saving mode. Figure 4: Power management simplified block diagram Pins with supply function are reported in Table 3, Table 7 and Table 9. LISA-U1/LISA-H1 series modules must be supplied via the VCC pins. There is only one main power supply input, available on the three VCC pins that must be all connected to the external power supply The VCC pins are directly connected to the RF power amplifiers and to the integrated Power Management Unit
(PMU) within the module: all supply voltages needed by the module are generated from the VCC supply by integrated voltage regulators. 3G.G2-HW-10002-2 Advance Information System description Page 16 of 116 Baseband Processor2G Power AmplifierSwitching Step-DownLISA-U1/LISA-H1 series5 x 10 F61VCC62VCC63VCC50VSIM2V_BCKP4V_INT2 x 3G Power Amplifier(s)Linear LDOLinear LDOSwitching Step-DownLinear LDOLinear LDOLinear LDOI/OEBUCOREAnalogSIMRTCNOR FlashDDR SRAMRF TransceiverMemoryPower Management Unit LISA-U1/LISA-H1 series - System Integration Manual V_BCKP is the Real Time Clock (RTC) supply. When the VCC voltage is within the valid operating range, the internal PMU supplies the Real Time Clock and the same supply voltage will be available to the V_BCKP pin. If the VCC voltage is under the minimum operating limit (for example, during not powered mode), the Real Time Clock can be externally supplied via the V_BCKP pin (see section 1.5.4). When a 1.8 V or a 3 V SIM card type is connected, LISA-U1/LISA-H1 series modules automatically supply the SIM card via the VSIM pin. Activation and deactivation of the SIM interface with automatic voltage switch from 1.8 to 3 V is implemented, in accordance to the ISO-IEC 7816-3 specifications. The same voltage domain used internally to supply the digital interfaces is also available on the V_INT pin, to allow more economical and efficient integration of the LISA-U1/LISA-H1 series modules in the final application. The integrated Power Management Unit also provides the control state machine for system start up and system reset control. 1.5.2 Module supply (VCC) The LISA-U1/LISA-H1 series modules must be supplied through the VCC pins by a DC power supply. Voltages must be stable: during operation, the current drawn from VCC can vary by some orders of magnitude, especially due to surging consumption profile of the GSM system (described in the section 1.5.3). It is important that the system power supply circuit is able to support peak power (refer to LISA-U1/LISA-H1 series Data Sheet [1] for specification). Name VCC Description Module power supply input GND Ground Table 3: Module supply pins Remarks VCC pins are internally connected, but all the available pads must be connected to the external supply in order to minimize the power loss due to series resistance. Clean and stable supply is required: low ripple and low voltage drop must be guaranteed. Voltage provided must always be above the minimum limit of the operating range. Consider that during a GSM call there are large current spikes in connected mode. GND pins are internally connected but a good (low impedance) external ground can improve RF performance: all available pads must be connected to ground. VCC pins ESD rating is 1 kV (contact discharge). A higher protection level can be required if the line is externally accessible on the application board. A higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) on the line connected to this pin. The voltage provided to the VCC pins must be within the normal operating range limits as specified in the LISA-U1/LISA-H1 series Data Sheet [1]. Complete functionality of the module is only guaranteed within the specified minimum and maximum VCC voltage operating range. Ensure that the input voltage at the VCC pins never drops below the minimum limit of the operating range when the module is switched on. This is the case even during a GSM transmit burst, where the current consumption can rise up to minimum peaks of 2.5 A in case of a mismatched antenna load. Operation above the operating range maximum limit is not recommended and extended exposure beyond it may affect device reliability. 3G.G2-HW-10002-2 Advance Information System description Page 17 of 116 LISA-U1/LISA-H1 series - System Integration Manual Stress beyond the VCC absolute maximum ratings can cause permanent damage to the module: if necessary, voltage spikes beyond VCC absolute maximum ratings must be restricted to values within the specified limits by using appropriate protection. When designing the power supply for the application, pay specific attention to power losses and transients. The DC power supply must be able to provide a voltage profile to the VCC pins with the following characteristics:
Voltage drop during transmit slots must be lower than 400 mV No undershoot or overshoot at the start and at the end of transmit slots Voltage ripple during transmit slots must be minimized Figure 5: Description of the VCC voltage profile versus time during a GSM call Any degradation in power supply performance (due to losses, noise or transients) will directly affect the RF performance of the module since the single external DC power source indirectly supplies all the digital and analog interfaces, and also directly supplies the RF power amplifier (PA). The voltage at the VCC pins must ramp from 2.5 V to 3.2 V within 1 ms. This VCC slope allows a proper switch on of the module, that is switched on when the voltage rises to the VCC operating range starting from a voltage value lower than 2.25 V. 1.5.2.1 VCC application circuits LISA-U1/LISA-H1 series modules must be supplied through the VCC pins by one (and only one) proper DC power supply that must be one of the following:
Switching regulator Low Drop-Out (LDO) linear regulator Rechargeable Li-Ion battery Primary (disposable) battery 3G.G2-HW-10002-2 Advance Information System description Page 18 of 116 TimeundershootovershootripplerippledropVoltage3.8 V (typ)RX slotunused slotunused slotTX slotunused slotunused slotMON slotunused slotRX slotunused slotunused slotTX slotunused slotunused slotMON slotunused slotGSM frame 4.615 ms (1 frame = 8 slots)GSM frame 4.615 ms (1 frame = 8 slots) LISA-U1/LISA-H1 series - System Integration Manual Figure 6: VCC supply concept selection The switching step-down regulator is the typical choice when the available primary supply source has a nominal voltage much higher (e.g. greater than 5 V) than the LISA-U1/LISA-H1 series modules operating supply voltage. The use of switching step-down provides the best power efficiency for the overall application and minimizes current drawn from the main supply source. The use of an LDO linear regulator becomes convenient for a primary supply with a relatively low voltage (e.g. less than 5 V). In this case the typical 90% efficiency of the switching regulator will diminish the benefit of voltage step-down and no true advantage will be gained in input current savings. On the opposite side, linear regulators are not recommended for high voltage step-down as they will dissipate a considerable amount of energy in thermal power. If LISA-U1/LISA-H1 series modules are deployed in a mobile unit where no permanent primary supply source is available, then a battery will be required to provide VCC. A standard 3-cell Lithium-Ion battery pack directly connected to VCC is the usual choice for battery-powered devices. During charging, batteries with Ni-MH chemistry typically reach a maximum voltage that is above the maximum rating for VCC, and should therefore be avoided. The use of primary (not rechargeable) battery is uncommon, since the most cells available are seldom capable of delivering the burst peak current for a GSM call due to high internal resistance. Keep in mind that the use of batteries requires the implementation of a suitable charger circuit (not included in LISA-U1/LISA-H1 series modules). The charger circuit should be designed in order to prevent over-voltage on VCC beyond the upper limit of the absolute maximum rating. The following sections highlight some design aspects for each of the supplies listed above. Switching regulator The characteristics of the switching regulator connected to VCC pins should meet the following requirements:
Power capability: the switching regulator with its output circuit must be capable of providing a voltage value to the VCC pins within the specified operating range and must be capable of delivering 2.5 A current pulses with 1/8 duty cycle to the VCC pins Low output ripple: the switching regulator together with its output circuit must be capable of providing a clean (low noise) VCC voltage profile High switching frequency: for best performance and for smaller applications select a switching frequency 600 kHz (since L-C output filter is typically smaller for high switching frequency). The use of a switching regulator with a variable switching frequency or with a switching frequency lower than 600 kHz must be carefully evaluated since this can produce noise in the VCC voltage profile and therefore negatively impact GSM modulation spectrum performance. An additional L-C low-pass filter between the switching regulator 3G.G2-HW-10002-2 Advance Information System description Page 19 of 116 Main Supply Available?BatteryLi-Ion 3.7 VLinear LDO RegulatorMain Supply Voltage >5 V?Switching Step-Down RegulatorNo, portable deviceNo, less than 5 VYes, greater than 5 VYes, always available LISA-U1/LISA-H1 series - System Integration Manual output to VCC supply pins can mitigate the ripple on VCC, but adds extra voltage drop due to resistive losses on series inductors PWM mode operation: select preferably regulators with Pulse Width Modulation (PWM) mode. While in active mode Pulse Frequency Modulation (PFM) mode and PFM/PWM mode transitions must be avoided to reduce the noise on the VCC voltage profile. Switching regulators able to switch between low ripple PWM mode and high efficiency burst or PFM mode can be used, provided the mode transition occurs when the GSM module changes status from idle mode (current consumption approximately 1 mA) to active mode
(current consumption approximately 100 mA): it is permissible to use a regulator that switches from the PWM mode to the burst or PFM mode at an appropriate current threshold (e.g. 60 mA) Output voltage slope: the use of the soft start function provided by some voltage regulator must be carefully evaluated, since the voltage at the VCC pins must ramp from 2.5 V to 3.2 V within 1 ms to allow a proper switch-on of the module Figure 7 and the components listed in Table 4 show an example of a high reliability power supply circuit, where the module VCC is supplied by a step-down switching regulator capable of delivering 2.5 A current pulses with low output ripple and with fixed switching frequency in PWM mode operation greater than 1 MHz. The use of a switching regulator is suggested when the difference from the available supply rail to the VCC value is high:
switching regulators provide good efficiency transforming a 12 V supply to the typical 3.8 V value of the VCC supply. Figure 7: Suggested schematic design for the VCC voltage supply application circuit using a step-down regulator 3G.G2-HW-10002-2 Advance Information System description Page 20 of 116 LISA-U1/LISA-H1 series12VC6R3C5R2C3C2C1R1VINRUNVCRTPGSYNCBDBOOSTSWFBGND671095C71238114C8C9L2D1R4R5L1C4U162VCC63VCC61VCCGND LISA-U1/LISA-H1 series - System Integration Manual Reference Description Part Number - Manufacturer C1 C2 C3 C4 C5 C6 C7 C8 C37 D1 L1 L2 R1 R2 R3 R4 R5 U1 47 F Capacitor Aluminum 0810 50 V MAL215371479E3 - Vishay 10 F Capacitor Ceramic X7R 5750 15% 50 V C5750X7R1H106MB - TDK 10 nF Capacitor Ceramic X7R 0402 10% 16 V GRM155R71C103KA01 - Murata 680 pF Capacitor Ceramic X7R 0402 10% 16 V GRM155R71H681KA01 - Murata 22 pF Capacitor Ceramic COG 0402 5% 25 V GRM1555C1H220JZ01 - Murata 10 nF Capacitor Ceramic X7R 0402 10% 16 V GRM155R71C103KA01 - Murata 470 nF Capacitor Ceramic X7R 0603 10% 25 V GRM188R71E474KA12 - Murata 22 F Capacitor Ceramic X5R 1210 10% 25 V GRM32ER61E226KE15 - Murata 330 F Capacitor Tantalum D_SIZE 6.3 V 45 m T520D337M006ATE045 - KEMET Schottky Diode 40 V 3 A MBRA340T3G - ON Semiconductor 10 H Inductor 744066100 30% 3.6 A 744066100 - Wurth Electronics 1 H Inductor 7445601 20% 8.6 A 7445601 - Wurth Electronics 470 k Resistor 0402 5% 0.1 W 15 k Resistor 0402 5% 0.1 W 22 k Resistor 0402 5% 0.1 W 390 k Resistor 0402 1% 0.063 W 100 k Resistor 0402 5% 0.1 W 2322-705-87474-L - Yageo 2322-705-87153-L - Yageo 2322-705-87223-L - Yageo RC0402FR-07390KL - Yageo 2322-705-70104-L - Yageo Step Down Regulator MSOP10 3.5 A 2.4 MHz LT3972IMSE#PBF - Linear Technology Table 4: Suggested components for the VCC voltage supply application circuit using a step-down regulator Low Drop-Out (LDO) linear regulator The characteristics of the LDO linear regulator connected to the VCC pins should meet the following requirements:
Power capabilities: the LDO linear regulator with its output circuit must be capable of providing a proper voltage value to the VCC pins and of delivering 2.5 A current pulses with 1/8 duty cycle Power dissipation: the power handling capability of the LDO linear regulator must be checked to limit its junction temperature to the maximum rated operating range (i.e. check the voltage drop from the max input voltage to the min output voltage to evaluate the power dissipation of the regulator) Output voltage slope: the use of the soft start function provided by some voltage regulators must be carefully evaluated, since the voltage at the VCC pins must ramp from 2.5 V to 3.2 V within 1 ms to allow a proper switch-on of the module Figure 8 and the components listed in Table 5 show an example of a power supply circuit, where the VCC module supply is provided by an LDO linear regulator capable of delivering 2.5 A current pulses, with proper power handling capability. The use of a linear regulator is suggested when the difference from the available supply rail and the VCC value is low: linear regulators provide high efficiency when transforming a 5 V supply to the 3.8 V typical value of the VCC supply. 3G.G2-HW-10002-2 Advance Information System description Page 21 of 116 LISA-U1/LISA-H1 series - System Integration Manual Figure 8: Suggested schematic design for the VCC voltage supply application circuit using an LDO linear regulator Reference Description Part Number - Manufacturer C1 C2 R1 R2 R3 U1 10 F Capacitor Ceramic X5R 0603 20% 6.3 V GRM188R60J106ME47 - Murata 10 F Capacitor Ceramic X5R 0603 20% 6.3 V GRM188R60J106ME47 - Murata 47 k Resistor 0402 5% 0.1 W 4.7 k Resistor 0402 5% 0.1 W 2.2 k Resistor 0402 5% 0.1 W LDO Linear Regulator ADJ 3.0 A RC0402JR-0747KL - Yageo Phycomp RC0402JR-074K7L - Yageo Phycomp RC0402JR-072K2L - Yageo Phycomp LT1764AEQ#PBF - Linear Technology Table 5: Suggested components for VCC voltage supply application circuit using an LDO linear regulator Rechargeable Li-Ion battery Rechargeable Li-Ion batteries connected to the VCC pins should meet the following requirements:
Maximum pulse and DC discharge current: the rechargeable Li-Ion battery with its output circuit must be capable of delivering 2.5 A current pulses with 1/8 duty-cycle to the VCC pins and must be capable of delivering a DC current greater than the module maximum average current consumption to VCC pins. The maximum pulse discharge current and the maximum DC discharge current are not always reported in battery data sheets, but the maximum DC discharge current is typically almost equal to the battery capacity in Amp-hours divided by 1 hour DC series resistance: the rechargeable Li-Ion battery with its output circuit must be capable of avoiding a VCC voltage drop greater than 400 mV during transmit bursts Primary (disposable) battery The characteristics of a primary (non-rechargeable) battery connected to VCC pins should meet the following requirements:
Maximum pulse and DC discharge current: the non-rechargeable battery with its output circuit must be capable of delivering 2.5 A current pulses with 1/8 duty-cycle to the VCC pins and must be capable of delivering a DC current greater than the module maximum average current consumption at the VCC pins. The maximum pulse and the maximum DC discharge current is not always reported in battery data sheets, but the maximum DC discharge current is typically almost equal to the battery capacity in Amp-hours divided by 1 hour DC series resistance: the non-rechargeable battery with its output circuit must be capable of avoiding a VCC voltage drop greater than 400 mV during transmit bursts 3G.G2-HW-10002-2 Advance Information System description Page 22 of 116 5VC1R1INOUTADJGND12453C2R2R3U1SHDNLISA-U1/LISA-H1 series62VCC63VCC61VCCGND LISA-U1/LISA-H1 series - System Integration Manual Additional hints for the VCC supply application circuits To reduce voltage drops, use a low impedance power source. The resistance of the power supply lines
(connected to the VCC and GND pins of the module) on the application board and battery pack should also be considered and minimized: cabling and routing must be as short as possible in order to minimize power losses. Three pins are allocated for VCC supply. Another twenty pins are designated for GND connection. Even if all the VCC pins and all the GND pins are internally connected within the module, it is recommended to properly connect all of them to supply the module in order to minimize series resistance losses. To avoid undershoot and overshoot on voltage drops at the start and end of a transmit burst during a GSM call
(when current consumption on the VCC supply can rise up to 2.5 A in the worst case), place a 330 F low ESR capacitor (e.g. KEMET T520D337M006ATE045) near the VCC pins. The use of very large capacitors (i.e. greater then 1000 F) on the VCC line and the use of the soft start function provided by some voltage regulators must be carefully evaluated, since the voltage at the VCC pins must ramp from 2.5 V to 3.2 V within 1 ms to allow a proper switch on of the module.To reduce voltage ripple and noise, place the following near the VCC pins:
100 nF capacitor (e.g Murata GRM155R61A104K) to filter digital logic noise from clocks and data sources 10 nF capacitor (e.g. Murata GRM155R71C103K) to filter digital logic noise from clocks and data sources 10 pF capacitor (e.g. Murata GRM1555C1E100J) to filter EMI in the 1800 / 1900 / 2100 MHz bands 39 pF capacitor (e.g. Murata GRM1555C1E390J) to filter EMI in the 850 / 900 MHz bands Figure 9 shows the complete configuration but the mounting of each single component depends on the application design. Figure 9: Suggested schematic design to reduce voltage ripple and noise and to avoid undershoot/ overshoot on voltage drops Reference Description Part Number - Manufacturer C1 C2 C3 C4 C5 330 F Capacitor Tantalum D_SIZE 6.3 V 45 m T520D337M006ATE045 - KEMET 100 nF Capacitor Ceramic X7R 0402 10% 16 V GRM155R61A104KA01 - Murata 10 nF Capacitor Ceramic X7R 0402 10% 16 V GRM155R71C103KA01 - Murata 39 pF Capacitor Ceramic C0G 0402 5% 25 V GRM1555C1E390JA01 - Murata 10 pF Capacitor Ceramic C0G 0402 5% 25 V GRM1555C1E100JA01 - Murata Table 6: Suggested components to reduce voltage ripple and noise and to avoid undershoot/ overshoot on voltage drops 3G.G2-HW-10002-2 Advance Information System description Page 23 of 116 3V8C1C4GNDC3C2C5LISA-U1/LISA-H1series62VCC63VCC61VCC+
LISA-U1/LISA-H1 series - System Integration Manual 1.5.3 Current consumption profiles During operation, the current drawn by the LISA-U1/LISA-H1 series modules through the VCC pins can vary by several orders of magnitude. This ranges from the high peak of current consumption during GSM transmitting bursts at maximum power level in 2G connected mode, to continuous high current drawn in UMTS connected mode, to the low current consumption during power saving in idle mode. 1.5.3.1 2G connected mode When a GSM call is established, the VCC consumption is determined by the current consumption profile typical of the GSM transmitting and receiving bursts. The current consumption peak during a transmission slot is strictly dependent on the transmitted power, which is regulated by the network. If the module is transmitting in GSM talk mode in the GSM 850 or in the E-GSM 900 band and at the maximum RF power control level (approximately 2 W or 33 dBm in the allocated transmit slot/burst) the current consumption can reach up to 2500 mA (with a highly unmatched antenna) for 576.9 s
(width of the transmit slot/burst) with a periodicity of 4.615 ms (width of 1 frame = 8 slots/burst), so with a 1/8 duty cycle according to GSM TDMA (Time Division Multiple Access). During a GSM call, current consumption is in the order of 100-200 mA in receiving or in monitor bursts and is about 30-50 mA in the inactive unused bursts (low current period). The more relevant contribution to determine the average current consumption is set by the transmitted power in the transmit slot. An example of current consumption profile of the data module in GSM talk mode is shown in Figure 10. Figure 10: VCC current consumption profile versus time during a GSM call (1 TX slot, 1 RX slot), with VCC=3.8 V When a GPRS connection is established there is a different VCC current consumption profile also determined by the transmitting and receiving bursts. In contrast to a GSM call, during a GPRS connection more than one slot can be used to transmit and/or more than one slot can be used to receive. The transmitted power depends on network conditions, which set the peak current consumption, but following the GPRS specifications the maximum transmitted RF power is reduced if more than one slot is used to transmit, so the maximum peak of current consumption is not as high as can be in case of a GSM call. If the module transmits in GPRS class 12 connected mode in the GSM 850 or in the E-GSM 900 band at the maximum power control level (27 dBm typical transmitted power in the transmit slot/burst), the current consumption can reach up to 1400 mA (with unmatched antenna). This happens for 2.307 ms (width of the 4 transmit slots/bursts) with a periodicity of 4.615 ms (width of 1 frame = 8 slots/bursts), so with a 1/2 duty cycle, according to GSM TDMA. 3G.G2-HW-10002-2 Advance Information System description Page 24 of 116 Time [ms]RX slotunused slotunused slotTX slotunused slotunused slotMON slotunused slotRX slotunused slotunused slotTX slotunused slotunused slotMON slotunused slotGSM frame 4.615 ms (1 frame = 8 slots)Current [A]200 mA~170 mA2500 mAPeak current depends on TX powerGSM frame 4.615 ms (1 frame = 8 slots)1.51.00.50.02.52.0~170 mA~40 mA LISA-U1/LISA-H1 series - System Integration Manual Figure 11 reports the current consumption profiles in GPRS mode with 4 slots used to transmit. Figure 11: VCC current consumption profile versus time during a GPRS/EDGE connection (4TX slots, 1 RX slot), with VCC=3.8 V In case of EDGE connections the VCC current consumption profile is very similar to the GPRS current profile, so the image shown in Figure 11 is valid for EDGE as well. 1.5.3.2 3G connected mode During a 3G connection, the module can transmit and receive continuously due to the Frequency Division Duplex
(FDD) mode of operation with the Wideband Code Division Multiple Access (WCDMA). The current consumption depends again on output RF power, which is always regulated by network commands. These power control commands are logically divided into a slot of 666 s, thus the rate of power change can reach a maximum rate of 1.5 kHz. There are no high current peaks as in the 2G connection, since transmission and reception are continuously enabled due to FDD WCDMA implemented in the 3G that differs from the TDMA implemented in the 2G case. In the worst scenario, corresponding to a continuous transmission and reception at maximum output power (approximately 250 mW or 24 dBm), the current drawn by the module at the VCC pins is in the order of continuous 600-700 mA. Even at lowest output RF power (approximately 0.01 W or -50 dBm), the current still remains in the order of 200 mA due to module baseband processing and transceiver activity. An example of current consumption profile of the data module in UMTS continuous transmission mode is shown in Figure 12. 3G.G2-HW-10002-2 Advance Information System description Page 25 of 116 Time [ms]RX slotunused slotTX slotTX slotTX slotTX slotMON slotunused slotRX slotunused slotTX slotTX slotTX slotTX slotMON slotunused slotGSM frame 4.615 ms (1 frame = 8 slots)Current [A]200mA~170mAPeak current depends on TX power~170mAGSM frame 4.615 ms (1 frame = 8 slots)1.51.00.50.02.52.0~40mA1400 mA LISA-U1/LISA-H1 series - System Integration Manual Figure 12: VCC current consumption profile versus time during a UMTS connection, with VCC=3.8 V When a packet data connection is established, the actual current profile depends on the amount of transmitted packets; there might be some periods of inactivity between allocated slots where current consumption drops about 100 mA. Alternatively, at higher data rates the transmitted power is likely to increase due to the higher quality signal required by the network to cope with enhanced data speed. 1.5.3.3 2G and 3G cyclic idle/active mode (power saving enabled) The power saving configuration is by default disabled, but it can be enabled using the appropriate AT command
(refer to u-blox AT Commands Manual [2], AT+UPSV command). When the power saving is enabled, the module automatically enters idle-mode whenever possible. When power saving is enabled, the module is registered or attached to a network and a voice or data call is not enabled, the module automatically enters idle-mode whenever possible, but it must periodically monitor the paging channel of the current base station (paging block reception), in accordance to GSM system requirements. When the module monitors the paging channel, it wakes up to active mode, to enable the reception of paging block. In between, the module switches to idle-mode. This is known as GSM discontinuous reception (DRX). The module processor core is activated during the paging block reception, and automatically switches its reference clock frequency from 32 kHz to the 26 MHz used in active-mode. The time period between two paging block receptions is defined by the network (2G or 3G). This is the paging period parameter, fixed by the base station through broadcast channel sent to all users on the same serving cell. In case of 2G network, the time interval between two paging block receptions can be from 470.76 ms (width of 2 GSM multiframes = 2 x 51 GSM frames = 2 x 51 x 4.615 ms) up to 2118.42 ms (width of 9 GSM multiframes
= 9 x 51 frames = 9 x 51 x 4.615 ms). In case of 3G network, the principle is similar but time interval changes from 640 ms (width of 26 x 3G frames =
64 x 10 ms = 640 ms) up to 5120 ms (width of 29 x 3G frames = 512 x 10 ms = 5120 ms). An example of a module current consumption profile is shown in Figure 13: the module is registered with the network (2G or 3G), automatically enters idle mode and periodically wakes up to active mode to monitor the paging channel for paging block reception. 3G.G2-HW-10002-2 Advance Information System description Page 26 of 116 Time [ms]3G frame 10 ms (1 frame = 15 slots)Current [mA]170 mADepends on TX power1 slot 666 s670 mA3002001000500400600700 LISA-U1/LISA-H1 series - System Integration Manual Figure 13: Description of VCC current consumption profile versus time when the module is registered with 2G or 3G networks:
the module is in idle mode and periodically wakes up to active mode to monitor the paging channel for paging block reception 1.5.3.4 2G and 3G fixed active mode (power saving disabled) Power saving configuration is by default disabled, or it can be disabled using the appropriate AT command (refer to u-blox AT Commands Manual [2], AT+UPSV command). When power saving is disabled, the module doesnt automatically enter idle-mode whenever possible: the module remains in active mode. The module processor core is activated during active-mode, and the 26 MHz reference clock frequency is used. An example of the current consumption profile of the data module when power saving is disabled is shown in Figure 14: the module is registered with the network, active-mode is maintained, and the receiver and the DSP are periodically activated to monitor the paging channel for paging block reception. 3G.G2-HW-10002-2 Advance Information System description Page 27 of 116
~30 msIDLE MODEACTIVE MODEIDLE MODE500-700 A8-10 mA20-22 mA~150 mAActive Mode EnabledIdle Mode EnabledPLL EnabledRX+DSP Enabled500-700 A~150 mA2G case: 0.44-2.09 s 3G case: 0.61-5.09 sIDLE MODE2G or 3G case: ~30 msACTIVE MODETime [s]Current [mA]150100500Time [ms]Current [mA]150100500 LISA-U1/LISA-H1 series - System Integration Manual Figure 14: Description of the VCC current consumption profile versus time when power saving is disabled: active-mode is always held, and the receiver and the DSP are periodically activated to monitor the paging channel for paging block reception 1.5.4 RTC Supply (V_BCKP) The V_BCKP pin connects the supply for the Real Time Clock (RTC) and Power On / Reset internal logic. This supply domain is internally generated by a linear regulator integrated in the Power Management Unit. The output of this linear regulator is always enabled when the main voltage supply provided to the module through VCC is within the valid operating range, with the module switched-off or powered-on. Name V_BCKP Description Real Time Clock supply Table 7: Real Time Clock supply pin Remarks V_BCKP = 2.3 V (typical) generated by the module to supply Real Time Clock when VCC supply voltage is within valid operating range. The V_BCKP pin ESD rating is 1 kV (contact discharge). A higher protection level could be required if the line is externally accessible on the application board. A higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) on the line connected to this pin. The RTC provides the time reference (date and time) of the module, also in power off mode, when the V_BCKP voltage is within its valid range (specified in u-blox LISA-U1/LISA-H1 series Data Sheet [1]). The RTC timing is 3G.G2-HW-10002-2 Advance Information System description Page 28 of 116 ACTIVE MODE20-22 mA20-22 mA~150 mARX+DSP Enabled20-22 mA~150 mA2G case: 0.47-2.12 s 3G case: 0.64-5.12 sPaging periodTime [s]Current [mA]150100500Time [ms]Current [mA]150100500 LISA-U1/LISA-H1 series - System Integration Manual normally used to set the wake-up interval during idle-mode periods between network paging, but is able to provide programmable alarm functions by means of the internal 32.768 kHz clock. The RTC can be supplied from an external back-up battery through the V_BCKP, when the main voltage supply is not provided to the module through VCC. This lets the time reference (date and time) run even when the main supply is not provided to the module. Consider that the module cannot switch on if a valid voltage is not present on VCC even when the RTC is supplied through V_BCKP (meaning that VCC is mandatory to switch-on the module). The RTC has very low power consumption, but is highly temperature dependent. For example at 25C and a V_BCKP voltage of 2.3 V the power consumption is approximately 2 A, whereas at 70C and an equal voltage the power consumption increases to 5-10 A. The internal regulator for V_BCKP is optimized for low leakage current and very light loads. It is not recommended to use V_BCKP to supply external loads. If V_BCKP is left unconnected and the module main voltage supply is removed from VCC, the RTC is supplied from the 100 nF capacitor mounted inside the module. However, this capacitor is not able to provide a long buffering time: within few milliseconds the voltage on V_BCKP will go below the valid range (1 V min). At this time the internal RTC will stop counting and the date and time setting will be lost. This has no impact on wireless connectivity, as all the functionalities of the module do not rely on the date and time setting. Leave V_BCKP unconnected if the RTC is not required when the VCC supply is removed. The date and time will not be updated when VCC is disconnected. If VCC is always supplied, then the internal regulator is supplied from the main supply and there is no need for an external component on V_BCKP. If RTC is required to run for a time interval of T [s] at 25C when VCC supply is removed, place a capacitor with a nominal capacitance of C [F] at the V_BCKP pin. Choose the capacitor using the following formula:
C [F] = (Current_Consumption [A] x T [s]) / Voltage_Drop [V] = 1.538 x T [s]
The RTC current consumption is approximately 2 A at 25C, and the voltage drop is equal to 1.3 V (from the V_BCKP typical value of 2.3 V to the valid range minimum limit of 1.0 V). For example, a 100 F capacitor (such as the Murata GRM43SR60J107M) can be placed at V_BCKP to provide a long buffering time. This capacitor will hold V_BCKP voltage within its valid range for around 50 s at 25C, after the VCC supply is removed. If a very long buffering time is required, a 70 mF super-capacitor (e.g. Seiko Instruments XH414H-IV01E) can be placed at V_BCKP, with a 4.7 k series resistor to hold the V_BCKP voltage within its valid range for approximately 10 hours at 25C, after the VCC supply is removed. The purpose of the series resistor is to limit the capacitor charging current due to the large capacitor specifications, and also to let a fast rise time of the voltage value at the V_BCKP pin after VCC supply has been provided. These capacitors will allow the time reference to run during battery disconnection. Figure 15: Real time clock supply (V_BCKP) application circuits : (a) using a 100 F capacitor to let the RTC run for ~50 s at 25C;
(b) using a 70 mF capacitor to let the RTC run for ~10 hours at 25C when the VCC supply is removed; (c) using non-rechargeable battery 3G.G2-HW-10002-2 Advance Information System description Page 29 of 116 LISA-U1/LISA-H1 seriesC1(a)2V_BCKPR2LISA-U1/LISA-H1 seriesC2(superCap)(b)2V_BCKPD3LISA-U1/LISA-H1 series2.3 V(c)2V_BCKP LISA-U1/LISA-H1 series - System Integration Manual Reference Description Part Number - Manufacturer C1 R2 C2 100 F Tantalum Capacitor GRM43SR60J107M - Murata 4.7 k Resistor 0402 5% 0.1 W RC0402JR-074K7L - Yageo Phycomp 70 mF Capacitor XH414H-IV01E - Seiko Instruments Table 8: Example of components for V_BCKP buffering If longer buffering time is required to allow the time reference to run during a disconnection of the VCC supply, then an external battery can be connected to V_BCKP pin. The battery should be able to provide a 2.3 V nominal voltage and must never exceed the maximum operating voltage for V_BCKP. The connection of the battery to V_BCKP should be done with a suitable series resistor for a rechargeable battery, or with an appropriate series diode for a non-rechargeable battery. The purpose of the series resistor is to limit the battery charging current due to the battery specifications, and also to allow a fast rise time of the voltage value at the V_BCKP pin after the VCC supply has been provided. The purpose of the series diode is to avoid a current flow from the module V_BCKP pin to the non-rechargeable battery. 1.5.5 Interface supply (V_INT) The same voltage domain used internally to supply the digital interfaces is also available on the V_INT pin. The internal regulator that generates the V_INT supply is a switching step down converter that is directly supplied from VCC. The voltage regulator output is set to 1.8 V (typical) when the module is switched on and is disabled when the module is switched off or when the RESET_N pin is forced the low level. The switching regulator operates in Pulse Width Modulation (PWM) for high output current mode but automatically switches to Pulse Frequency Modulation (PFM) at low output loads for greater efficiency, e.g. when the module is in idle mode between paging periods. Name V_INT Description Remarks Digital Interfaces supply output V_INT = 1.8V (typical) generated by the module when it is switched-on and the RESET_N (external reset input pin) is not forced to the low level. V_INT is the internal supply for digital interfaces. The user may draw limited current from this supply rail. Table 9: Interface supply pin The V_INT pin ESD rating is 1 kV (contact discharge). A higher protection level could be required if the line is externally accessible on the application board. A higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) on the line connected to this pin. Since it supplies internal digital circuits (see Figure 4), V_INT is not suited to directly supply any sensitive analog circuit: the voltage ripple can range from 15 mVpp during active mode (PWM), to 70 mVpp in idle mode (PFM). V_INT can be used to supply external digital circuits operating at the same voltage level as the digital interface pins, i.e. 1.8 V (typical). It is not recommended to supply analog circuitry without adequate filtering for digital noise. Dont apply loads which might exceed the limit for maximum available current from V_INT supply, as this can cause malfunctions in internal circuitry supplies to the same domain. The detailed electrical characteristics are described in the LISA-U1/LISA-H1 series Data Sheet [1]. 3G.G2-HW-10002-2 Advance Information System description Page 30 of 116 LISA-U1/LISA-H1 series - System Integration Manual V_INT can only be used as an output; dont connect any external regulator on V_INT. If not used, this pin should be left unconnected. The V_INT digital interfaces supply output is mainly used to:
Pull-up DDC (I2C) interface signals (see section 1.10 for more details) Pull-up SIM detection signal (see section 1.8 for more details) Indicate when the module is switched on and the RESET_N (external reset input pin) is not forced to the low level 1.6 System functions 1.6.1 Module power on The module power on sequence is initiated in one of 3 ways:
Rising edge on the VCC pin to a valid voltage for module supply Falling edge on the PWR_ON pin Rising edge on the RESET_N pin RTC alarm Name Description PWR_ON Power on input Table 10: Power on pin Remarks PWR_ON pin has high input impedance. Do not keep floating in noisy environment: external pull-up required. The PWR_ON pin ESD rating is 1 kV (contact discharge). A higher protection level could be required if the line is externally accessible on the application board. A higher protection level can be achieved mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) on the line connected to this pin. 1.6.1.1 Rising edge on VCC When a supply is connected to VCC pins, the module supply supervision circuit controls the subsequent activation of the power up state machines: the module is switched on when the voltage rises up to the VCC operating range minimum limit (3.4 V) starting from a voltage value lower than 2.25 V (See LISA-U1/LISA-H1 series Data Sheet [1]). The voltage at the VCC pins must ramp from 2.5 V to 3.2 V within 1 ms to switch on the module. 1.6.1.2 Falling edge on PWR_ON The module power on sequence starts when a falling edge is forced on the PWR_ON input pin. After applying a falling edge, it is suggested to hold a low level on the PWR_ON signal for at least 5 ms to properly switch on the module. The electrical characteristics of the PWR_ON input pin are different from the other digital I/O interfaces: the high and the low logic levels have different operating ranges and the pin is tolerant to voltages up to the battery voltage. The detailed electrical characteristics are described in the LISA-U1/LISA-H1 series Data Sheet [1]. 3G.G2-HW-10002-2 Advance Information System description Page 31 of 116 LISA-U1/LISA-H1 series - System Integration Manual The PWR_ON pin has high input impedance and is weakly pulled to the high level on the module. Avoid keeping it floating in a noisy environment. To hold the high logic level stable, the PWR_ON pin must be connected to a pull-up resistor (e.g. 100 k) biased by the V_BCKP supply pin of the module. Once the module has turned on, moving the PWR_ON pin has no effect. On the other hand it makes no sense to keep this pin low once the module has been turned on: if the pin is kept low it will draw unnecessary current. Following are some typical examples of application circuits to turn the module on using the PWR_ON input pin. The simplest way to turn on the module is to use a push button that shorts the PWR_ON pin to ground: in this case the V_BCKP supply pin or the VCC supply of the module can be used to bias the pull-up resistor. If the PWR_ON input is connected to an external device (e.g. application processor), it is suggested to use an open drain output on the external device with an external pull-up resistor (e.g. 100 k) biased by the V_BCKP supply pin of the module. A push-pull output of an application processor can also be used: in this case the pull-up can be used to pull the PWR_ON level high when the application processor is switched off. If the high-level voltage of the push-pull output pin of the application processor is greater than the maximum voltage value as V_BCKP operating range, the V_BCKP supply cannot be used to bias the pull-up resistor: the supply rail of the application processor or the VCC supply could be used, but this will increase the V_BCKP (RTC supply) current consumption when the module is in not-powered mode (VCC supply not present). To avoid an unwanted switch on of the module be sure to fix the proper level on PWR_ON in all possible scenarios. Figure 16: PWR_ON application circuits using a push button and an open drain output of an application processor Reference Description Remarks Rext ESD 100 k Resistor 0402 5% 0.1 W External pull-up resistor CT0402S14AHSG - EPCOS Varistor array for ESD protection Table 11: Example of pull-up resistor and ESD protection for the PWR_ON application circuits 1.6.1.3 Rising edge on RESET_N The module can be switched on by means of the RESET_N input pin: the RESET_N signal must be forced to the low level for at least 50 ms and then released from the low level to generate a rising edge that starts the module power-on sequence. 3G.G2-HW-10002-2 Advance Information System description Page 32 of 116 LISA-U1/LISA-H1 seriesRext2V_BCKP19PWR_ONPower-on push buttonESDOpen Drain OutputApplication ProcessorLISA-U1/LISA-H1 seriesRext2V_BCKP19PWR_ON LISA-U1/LISA-H1 series - System Integration Manual The RESET_N input pin can also be used to perform an external or hardware reset of the module, as described in the section 1.6.3. The electrical characteristics of RESET_N are different from the other digital I/O interfaces. The detailed electrical characteristics are described in the LISA-U1/LISA-H1 series Data Sheet [1]. RESET_N is pulled high to V_BCKP by an integrated pull-up resistor also when the module is in power off mode. Therefore an external pull-up should not be required on the application board. The simplest way to switch on the module by means of the RESET_N input pin is to use a push button that shorts the RESET_N pin to ground: the module will be switched on at the release of the push button, since the RESET_N will be forced to the high level by the integrated pull-up resistor, generating a rising edge. If RESET_N is connected to an external device (e.g. an application processor on an application board) an open drain output can be directly connected without any external pull-up. A push-pull output can be used too: in this case make sure that the high level voltage of the push-pull circuit is below the maximum voltage value of the V_BCKP operating range. Make sure to fix the proper level on RESET_N in all possible scenarios, to avoid unwanted switch-on or reset of the module. Some typical examples of application circuits using the RESET_N input pin are described in the section 1.6.3. 1.6.1.4 Real Time Clock (RTC) alarm If a voltage within the operating range is maintained at the VCC pin, the module can be switched on by the RTC alarm when the RTC system reaches a pre-programmed scheduled time. The RTC system will then initiate the boot sequence by instructing the Power Management Unit to turn on power. Also included in this setup is an interrupt signal from the RTC block to indicate to the baseband processor that an RTC event has occurred. 1.6.1.5 Additional considerations The module is switched on when the voltage rises up to the VCC operating range: the first time that the module is used, it is switched on in this way. Then, the proper way to switch off the module is by means of the AT+CPWROFF command. When the module is in power-off mode, i.e. the AT+CPWROFF command has been sent and a voltage value within the operating range limits is still provided to the VCC pin, the digital input-
output pads of the baseband chipset (i.e. all the digital pins of the module) are locked in tri-state (i.e. floating). The power down tri-state function isolates the module pins from its environment, when no proper operation of the outputs can be guaranteed. The module can be switched on from power-off mode by forcing a proper start-up event (i.e. a falling edge on the PWR_ON pin, or an RTC alarm). After the detection of a start-up event, all the digital pins of the module are held in tri-state until all the internal LDO voltage regulators are turned on in a defined power-on sequence. Then, as described in Figure 17, the baseband core is still held in reset state for a time interval: the internal reset signal
(which is not available on a module pin) is still low and any signal from the module digital interfaces is held in reset state. The reset state of all the digital pins is reported in the pin description table of the LISA-U1/LISA-H1 series Data Sheet [1]. When the internal signal is released, the configuration of the module interfaces starts:
during this phase any digital pin is set in a proper sequence from the reset state to the default operational configuration. Finally, the module is fully ready to operate when all interfaces are configured. 3G.G2-HW-10002-2 Advance Information System description Page 33 of 116 LISA-U1/LISA-H1 series - System Integration Manual Figure 17: LISA power on sequence description (* - the PWR_ON signal state is not relevant during this phase) The Internal Reset signal is not available on a module pin. 3G.G2-HW-10002-2 Advance Information System description Page 34 of 116 VCCV_BCKPPWR_ONV_INTInternal ResetSystem StateBB Pads StateInternal Reset OperationalOperationalTristate / Floating Internal ResetOFFON*Start-up event0 ms~5 ms~6 ms~35 ms~1000 msPWR_ON can be set highStart of interface configurationAll interfaces are configured LISA-U1/LISA-H1 series - System Integration Manual 1.6.2 Module power off The correct way to switch off LISA-U1/LISA-H1 series modules is by means of +CPWROFF AT command (more details in u-blox AT Commands Manual [2]): in this way the current parameter settings are saved in the modules non-volatile memory and a proper network detach is performed. An under-voltage shutdown will be done if the VCC supply is removed, but in this case the current parameter settings are not saved in the modules non-volatile memory and a proper network detach cannot be performed. The power off sequence is described in Figure 18. When the +CPWROFF AT command is sent, the module starts the switch-off routine replying OK on the AT interface: during this phase, the current parameter settings are saved in the modules non-volatile memory, a network detach is performed and all module interfaces are disabled (i.e. the digital pins are locked in tri-state by the module). Since the time to perform a network detach depends on the network settings, the duration of this phase can differ from the typical value reported in the following figure. At the end of the switch-off routine, all the digital pins are locked in tri-state by the module and all the internal LDO voltage regulators except the RTC supply (V_BCKP) are turned off in a defined power off sequence. The module remains in power off mode as long as a switch on event doesnt occur (i.e. a falling edge on the PWR_ON pin or an RTC alarm), and enters not-powered mode if the supply is removed from the VCC pin. Figure 18: LISA Power off sequence description (* - the PWR_ON signal state is not relevant during this phase) The Internal Reset signal is not available on a module pin. Tristated pins are always subject to floating caused by noise: to prevent unwanted effects, fix them with proper pull-up or pull down resistors to stable voltage rails to fix their level when the module is in Power down state. 3G.G2-HW-10002-2 Advance Information System description Page 35 of 116 VCCV_BCKPPWR_ON*V_INTInternal ResetSystem StateBB Pads StateOperationalOFFTristate / Floating ONOperational Tristate / FloatingAT+CPWROFFsent to the module0 ms~50 ms~400 msOKreplied by the module LISA-U1/LISA-H1 series - System Integration Manual 1.6.3 Module reset The module reset can be performed in one of 2 ways:
Forcing a low level on the RESET_N pin, causing an external or hardware reset Via AT command, causing an internal or software reset LISA-U1/LISA-H1 series modules can be reset using the RESET_N pin: when the RESET_N pin is forced low for at least 50 ms, an external or hardware reset is performed. This causes an asynchronous reset of the entire module, including the integrated Power Management Unit, except for the RTC internal block: the V_INT interfaces supply is switched off and all the digital pins are tri-stated, but the V_BCKP supply and the RTC block are enabled. Forcing an external or hardware reset, the current parameter settings are not saved in the modules non-volatile memory and a proper network detach is not performed. LISA-U1/LISA-H1 series modules can also be reset by means of the AT+CFUN command (more details in u-blox AT Commands Manual [2]): in this case an internal or software reset is performed, causing an asynchronous reset of the baseband processor, excluding the integrated Power Management Unit and the RTC internal block:
the V_INT interfaces supply is enabled and each digital pin is set in its internal reset state (reported in the pin description table in the LISA-U1/LISA-H1 series Data Sheet [1]), the V_BCKP supply and the RTC block are enabled. Forcing an internal or software reset, the current parameter settings are saved in the modules non-volatile memory and a proper network detach is performed. When RESET_N is released from the low level, the module automatically starts its power on sequence from the reset state. The same procedure is followed for the module reset via AT command after having performed the network detach and the parameter saving in non-volatile memory. The internal reset state of all digital pins is reported in the pin description table in LISA-U1/LISA-H1 series Data Sheet [1]. Name RESET_N Table 12: Reset pin Description External reset input Remarks Internal 10 k pull-up to V_BCKP The RESET_N pin ESD rating is 1 kV (contact discharge). A higher protection level could be required if the line is externally accessible on the application board. A higher protection level can be achieved mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) on the line connected to this pin. For more details about the general precautions for ESD immunity about RESET_N pin please refer to chapter 2.5.1. The electrical characteristics of RESET_N are different from the other digital I/O interfaces. The detailed electrical characteristics are described in the LISA-U1/LISA-H1 series Data Sheet [1]. RESET_N is pulled high by an integrated 10 k pull-up resistor to V_BCKP. Therefore an external pull-up is not required on the application board. Following are some typical examples of application circuits using the RESET_N input pin. The simplest way to reset the module is to use a push button that shorts the RESET_N pin to ground. If RESET_N is connected to an external device (e.g. an application processor on an application board) an open drain output can be directly connected without any external pull-up. A push-pull output can be used too: in this case make sure that the high level voltage of the push-pull circuit is below the maximum voltage value of the V_BCKP operating range. To avoid unwanted reset of the module make sure to fix the proper level on RESET_N in all possible scenarios. As ESD immunity test precaution, a 47 pF bypass capacitor (e.g. Murata GRM1555C1H470JA01) and a series ferrite bead (e.g. Murata BLM15HD182SN1) must be added on the RESET_N line pin to avoid a module reset caused by an electrostatic discharge applied to the application board (for more details, refer to chapter 2.5.1). 3G.G2-HW-10002-2 Advance Information System description Page 36 of 116 LISA-U1/LISA-H1 series - System Integration Manual Figure 19: RESET_N application circuits using a push button and an open drain output of an application processor Reference Description Remarks ESD C1, C2 FB1, FB2 Rint Varistor for ESD protection. CT0402S14AHSG - EPCOS 47 pF Capacitor Ceramic C0G 0402 5% 50 V GRM1555C1H470JA01 - Murata Chip Ferrite Bead for Noise/EMI Suppression BLM15HD182SN1 - Murata 10 k Resistor 0402 5% 0.1 W Internal pull-up resistor Table 13: Example of ESD protection components for the RESET_N application circuit 1.7 RF connection The ANT pin has 50 nominal characteristic impedance and must be connected to the antenna through a 50 transmission line to allow transmission and reception of radio frequency (RF) signals in the GSM and UMTS operating bands. Name ANT Description RF antenna Table 14: Antenna pin Remarks Zo = 50 nominal characteristic impedance. The ANT port ESD rating is 500 V (contact discharge). A higher protection level could be required if the line is externally accessible on the application board. Choose an antenna with optimal radiating characteristics for the best electrical performance and overall module functionality. An internal antenna, integrated on the application board, or an external antenna, connected to the application board through a proper 50 connector, can be used. See section 2.4 and section 2.2.1.1 for further details regarding antenna guidelines. 3G.G2-HW-10002-2 Advance Information System description Page 37 of 116 LISA-U1/LISA-H1 series2V_BCKP22RESET_NReset push buttonESDOpen Drain OutputApplication ProcessorLISA-U1/LISA-H1 series2V_BCKP22RESET_NRintRintFB1C1FB2C2 LISA-U1/LISA-H1 series - System Integration Manual The recommendations of the antenna producer for correct installation and deployment (PCB layout and matching circuitry) must be followed. If an external antenna is used, the PCB-to-RF-cable transition must be implemented using either a suitable 50 connector, or an RF-signal solder pad (including GND) that is optimized for 50 characteristic impedance. If antenna supervisor functionality is required, the antenna should have a built in DC diagnostic resistor to ground to get proper antenna detection functionality (See section 2.4.3). 1.8 (U)SIM interface A (U)SIM card interface is provided on the SMT pads of the LISA-U1/LISA-H1 series modules: the high-speed SIM/ME interface is implemented as well as automatic detection of the required SIM supporting voltage. Both 1.8 V and 3 V SIM types are supported: activation and deactivation with automatic voltage switch from 1.8 V to 3 V is implemented, according to ISO-IEC 7816-3 specifications. The SIM driver supports the PPS
(Protocol and Parameter Selection) procedure for baud-rate selection, according to the values determined by the SIM Card. Name VSIM SIM_CLK SIM_IO SIM_RST Description SIM supply SIM clock SIM data SIM reset Table 15: SIM Interface pins Remarks 1.80 V typical or 2.90 V typical Automatically generated by the module 3.25 MHz clock frequency Open drain, internal 4.7 k pull-up resistor to VSIM A low capacitance ESD protection (e.g. Infineon ESD8V0L2B-03L or AVX USB0002RP) must be placed near the SIM card holder on each line (VSIM, SIM_IO, SIM_CLK, SIM_RST). The SIM interface pins ESD rating is 1 kV (contact discharge): higher protection level is required if the lines are connected to an SIM card holder/connector, since they are externally accessible on the application board. For more details about the general precautions for ESD immunity about SIM interface pins please refer to chapter 2.5.1. Figure 20 shows an application circuit connecting the LISA module and the SIM card placed in a SIM card holder, using the SIM detection function provided by GPIO5 pin. Note that, as defined by ETSI TS 102 221 or ISO/IEC 7816, SIM card contacts assignment is the following:
Contact C1 = VCC (Supply) It must be connected to VSIM Contact C2 = RST (Reset) It must be connected to SIM_RST Contact C3 = CLK (Clock) It must be connected to SIM_CLK Contact C4 = AUX1 (Auxiliary contact for USB interface and other uses) It must be left not connected Contact C5 = GND (Ground) It must be connected to GND Contact C6 = VPP (Programming supply) It must be connected to VSIM Contact C7 = I/O (Data input/output) It must be connected to SIM_IO Contact C8 = AUX2 (Auxiliary contact for USB interface and other uses) It must be left not connected A SIM card can have 6 contacts (C1 = VCC, C2 = RST, C3 = CLK, C5 = GND, C6 = VPP, C7 = I/O) or 8 contacts
(providing also the auxiliary contacts C4 = AUX1 and C8 = AUX2). The contacts number depends if additional 3G.G2-HW-10002-2 Advance Information System description Page 38 of 116 LISA-U1/LISA-H1 series - System Integration Manual features, that are not supported by the (U)SIM card interface of the LISA-U1/LISA-H1 series modules, are provided by the SIM card (contacts C4 = AUX1 and C8 = AUX2 for USB interfaces and other uses). A SIM card holder can have 6 or 8 positions if a mechanical card presence detector is not provided, or it can have 6+2 or 8+2 positions if two additional pins for the mechanical card presence detection are provided. Figure 20 shows an application circuit connecting a LISA-U1/LISA-H1 series module and a SIM card placed in a SIM card holder with 6+2 pins (as the CCM03-3013LFT R102 connector, produced by C&K Components, which provides 2 pins for the mechanical card presence detection), using the SIM detection function provided by the GPIO5 of LISA-U1/LISA-H1 series module. This configuration allows the module to detect if a SIM card is present in the connector. The SW1 and SW2 pins of the SIM card holder are connected to a normally-open mechanical switch integrated in the SIM connector. The following cases are available SIM card not present: the GPIO5 signal is forced low by the pull-down resistor connected to ground (i.e. the switch integrated in the SIM connector is open) SIM card present: the GPIO5 signal is forced high by the pull-up resistor connected to V_INT (i.e. the switch integrated in the SIM connector is closed) Figure 20: SIM interface application circuit Reference Description Part Number - Manufacturer C1, C2, C3, C4 33 pF Capacitor Ceramic COG 0402 5% 25 V GRM1555C1H330JZ01 - Murata C5 100 nF Capacitor Ceramic X7R 0402 10% 16 V GRM155R71C104KA01 - Murata D1, D2, D3 ESD Transient Voltage Suppressor USB0002RP or USB0002DP - AVX R1 R2 J1 1 k Resistor 0402 5% 0.1 W 470 k Resistor 0402 5% 0.1 W SIM Card Holder Table 16: Example of components for SIM card connection RC0402JR-071KL - Yageo Phycomp RC0402JR-07470KL- Yageo Phycomp Various Manufacturers, CCM03-3013LFT R102 - C&K Components When connecting the module to an SIM connector, perform the following steps on the application board:
Bypass digital noise via a 100 nF capacitor (e.g. Murata GRM155R71C104K) on the SIM supply (VSIM) To prevent RF coupling in case the module RF antenna is placed closer than 10 - 30 cm from the SIM card holder, connect a bypass capacitor of about 22 pF to 47 pF (e.g. Murata GRM1555C1H470J) at each SIM signal (VSIM, SIM_CLK, SIM_IO, SIM_RST) to ground near the SIM connector Mount very low capacitance ESD protection (e.g. Infineon ESD8V0L2B-03L or AVX USB0002) near the SIM card connector 3G.G2-HW-10002-2 Advance Information System description Page 39 of 116 LISA-U1/LISA-H1 seriesC1SIM CARD HOLDERCCVCC (C1)CCVPP (C6)CCIO (C7)CCCLK (C3)CCRST (C2)GND (C5)C2C3C5D2D3C5C6C7C1C2C3SIM Card Bottom View (contacts side)J150VSIM48SIM_IO47SIM_CLK49SIM_RSTC4SW1SW24V_INT51GPIO5R2R1D1 LISA-U1/LISA-H1 series - System Integration Manual Limit capacitance and series resistance on each SIM signal to match the requirements for the SIM interface
(27.7 ns is the maximum allowed rise time on the SIM_CLK line, 1.0 s is the maximum allowed rise time on the SIM_IO and SIM_RST lines): always route the connections to keep them as short as possible 1.8.1 (U)SIM functionality The following SIM services are supported:
Abbreviated Dialing Numbers (ADN) Fixed Dialing Numbers (FDN) Last Dialed Numbers (LDN) Service Dialing Numbers (SDN) USIM Application Toolkit (USAT) is supported. 3G.G2-HW-10002-2 Advance Information System description Page 40 of 116 LISA-U1/LISA-H1 series - System Integration Manual 1.9 Serial communication LISA-U1/LISA-H1 series modules provide AT command interface, Packet-Switched / Circuit-Switched Data communication on the following serial communication interfaces:
One asynchronous serial interface (UART) that provides complete RS-232 functionality conforming to ITU-T V.24 Recommendation [3], with limited data rate. The UART interface can be used for firmware upgrade One Inter Processor Communication (IPC) interface that includes a synchronous SPI-compatible interface, with maximum data rate of 20 Mb/s One high-speed USB 2.0 compliant interface, with maximum data rate of 480 Mb/s. The single USB interface implements 6 logical devices. Each device is a USB communications device class (or USB CDC), that is a composite Universal Serial Bus device class. The USB interface can be used for firmware upgrade The LISA-U1/LISA-H1 series modules are designed to operate as an HSPA wireless modem, which represents the data circuit-terminating equipment (DCE) as described by the ITU-T V.24 Recommendation [3]. A customer application processor connected to the module through one of the interfaces represents the data terminal equipment (DTE). All the interfaces listed above are controlled and operated with:
AT commands according to 3GPP TS 27.007 [4]
AT commands according to 3GPP TS 27.005 [5]
AT commands according to 3GPP TS 27.010 [6]
u-blox AT commands For the complete list of supported AT commands and their syntax refer to the u-blox AT Commands Manual [2]. The following serial communication interfaces can be used for firmware upgrade:
The UART interface, using the RxD and TxD lines only The USB interface, using all the lines provided (VUSB_DET, USB_D+ and USB_D-) To directly enable PC (or similar) connection to the module for firmware upgrade, provide direct access on the application board to the VUSB_DET, USB_D+ and USB_D- lines of the module (or to the RxD and TxD lines). Also provide access to the PWR_ON or the RESET_N pins, or enable the DC supply connected to the VCC pin to start the module firmware upgrade (see Firmware Update Application Note
[14]). The following sub-chapters describe the serial interfaces configuration and provide a detailed description of each interface for the application circuits. 1.9.1 Serial interfaces configuration UART, USB and SPI/IPC serial interfaces are available as AT command interface and for Packet-Switched / Circuit-
Switched Data communication. The serial interfaces are configured as described in Table 17 (for information about further settings, please refer to the u-blox AT Commands Manual [2]). 3G.G2-HW-10002-2 Advance Information System description Page 41 of 116 LISA-U1/LISA-H1 series - System Integration Manual Interface AT Settings Comments UART interface Enabled Multiplexing mode can be enabled by AT+CMUX command providing following channels:
Channel 0: control channel Channel 1 5: AT commands /data connection Channel 6: GPS tunneling AT+IPR=115200 Baud rate: 115200 b/s AT+ICF=0,0 Frame format: 8 bits, no parity, 1 stop bit AT&K3 AT&S1 AT&D1 AT&C1 HW flow control enabled DSR line set ON in data mode and set OFF in command mode Upon an ON-to-OFF transition of DTR, the DCE enters online command state and issues an OK result code Circuit 109 changes in accordance with the Carrier detect status; ON if the Carrier is detected, OFF otherwise USB interface Enabled 6 CDCs are available, configured as described in the following list:
USB1: AT commands / data connection USB2: AT commands / data connection USB3: AT commands / data connection USB4: GPS tunneling dedicated port USB5: 2G trace dedicated port USB6: 3G trace dedicated port AT&K3 AT&S1 AT&D1 AT&C1 HW flow control enabled DSR line set ON in data mode and set OFF in command mode Upon an ON-to-OFF transition of DTR, the DCE enters online command state and issues an OK result code Circuit 109 changes in accordance with the Carrier detect status; ON if the Carrier is detected, OFF otherwise SPI interface Enabled Multiplexing mode can be enabled by AT+CMUX command providing following channels:
AT&K3 AT&S1 AT&D1 AT&C1 Channel 0: control channel Channel 1 5: AT commands /data connection Channel 6: GPS tunneling HW flow control enabled DSR line set ON in data mode and set OFF in command mode Upon an ON-to-OFF transition of DTR, the DCE enters online command state and issues an OK result code Circuit 109 changes in accordance with the Carrier detect status; ON if the Carrier is detected, OFF otherwise Table 17: Default serial interfaces configuration 1.9.2 Asynchronous serial interface (UART) The UART interface is a 9-wire unbalanced asynchronous serial interface that provides AT commands interface, PSD and CSD data communication, firmware upgrade. UART interface provides RS-232 functionality conforming to the ITU-T V.24 Recommendation (more details available in ITU Recommendation [3]), with CMOS compatible signal levels: 0 V for low data bit or ON state, and 1.8 V for high data bit or OFF state. Two different external voltage translators (Maxim MAX3237E and On Semiconductor NLSX3018MUTAG) could be used to provide full RS-232 (9 lines) compatible signal levels. The On Semiconductor chip provides the translation from 1.8 V to 3.3 V, while the Maxim chip provides the necessary RS-232 compatible signal towards the external connector. If a UART interface with only 5 lines is needed, the Maxim 13234E voltage level translator can be used. This chip translates the voltage levels from 1.8 V (module side) to the RS-232 standard. For detailed electrical characteristics refer to the LISA-U1/LISA-H1 series Data Sheet
[1]. The LISA-U1/LISA-H1 series modules are designed to operate as an HSPA wireless modem, which represents the data circuit-terminating equipment (DCE) as described by the ITU-T V.24 Recommendation [3]. A customer application processor connected to the module through the UART interface represents the data terminal equipment (DTE). 3G.G2-HW-10002-2 Advance Information System description Page 42 of 116 LISA-U1/LISA-H1 series - System Integration Manual The signal names of the LISA-U1/LISA-H1 series modules UART interface conform to the ITU-T V.24 Recommendation [3]. UART interfaces include the following lines:
Name DSR RI DCD DTR RTS CTS TxD RxD GND Description Data set ready Ring Indicator Data carrier detect Data terminal ready Ready to send Clear to send Transmitted data Received data Ground Table 18: UART interface signals Remarks Module output Circuit 107 (Data set ready) in ITU-T V.24 Module output Circuit 125 (Calling indicator) in ITU-T V.24 Module output Circuit 109 (Data channel received line signal detector) in ITU-T V.24 Module input Circuit 108/2 (Data terminal ready) in ITU-T V.24 Internal active pull-up to V_INT (1.8 V) enabled. Module hardware flow control input Circuit 105 (Request to send) in ITU-T V.24 Internal active pull-up to V_INT (1.8 V) enabled. Module hardware flow control output Circuit 106 (Ready for sending) in ITU-T V.24 Module data input Circuit 103 (Transmitted data) in ITU-T V.24 Internal active pull-up to V_INT (1.8 V) enabled. Module data output Circuit 104 (Received data) in ITU-T V.24 The UART interface pins ESD rating is 1 kV (contact discharge). A higher protection level could be required if the lines are externally accessible on the application board. A higher protection level can be achieved mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) on the lines connected to these pins. 1.9.2.1 UART features All flow control handshakes are supported by the UART interface and can be set by appropriate AT commands
(see u-blox AT Commands Manual [2], &K, +IFC, \Q AT commands): hardware flow control (RTS/CTS), software flow control (XON/XOFF), or none flow control. Hardware flow control is enabled by default. The following baud rates can be configured using AT commands:
1200 b/s 2400 b/s 4800 b/s 9600 b/s 19200 b/s 38400 b/s 3G.G2-HW-10002-2 Advance Information System description Page 43 of 116 LISA-U1/LISA-H1 series - System Integration Manual 57600 b/s 115200 b/s 230400 b/s 460800 b/s The default baud rate is 115200 b/s. Autobauding is not supported. The frame format can be:
8N1 (8 data bits, No parity, 1 stop bit) 8E1 (8 data bits, even parity, 1 stop bit) 8O1 (8 data bits, odd parity, 1 stop bit) 8N2 (8 data bits, No parity, 2 stop bits) 7E1 (7 data bits, even parity, 1 stop bit) 7O1 (7 data bits, odd parity, 1 stop bit) The default frame configuration with fixed baud rate is 8N1, described in the Figure 21. Figure 21: UART default frame format (8N1) description 1.9.2.2 UART signal behavior (AT commands interface case) See Table 2 for a description of operating modes and states referred to in this section. At the switch on of the module, before the initialization of the UART interface, as described in the power on sequence reported in the Figure 17, each pin is first tri-stated and then is set to its relative internal reset state that is reported in the pin description table in LISA-U1/LISA-H1 series Data Sheet [1]. At the end of the boot sequence, the UART interface is initialized, the module is by default in active mode and the UART interface is enabled. The configuration and the behavior of the UART signals after the boot sequence are described below. For a complete description of data and command mode please refer to u-blox AT Commands Manual
[2]. RxD signal behavior The module data output line (RxD) is set by default to OFF state (high level) at UART initialization. The module holds RxD in OFF state until no data is transmitted by the module. 3G.G2-HW-10002-2 Advance Information System description Page 44 of 116 D0D1D2D3D4D5D6D7Start of 1-BytetransferStart Bit(Always 0)Possible Start ofnext transferStop Bit(Always 1)tbit = 1/(Baudrate)Normal Transfer,8N1 LISA-U1/LISA-H1 series - System Integration Manual TxD signal behavior The module data input line (TxD) is set by default to OFF state (high level) at UART initialization. The TxD line is then held by the module in the OFF state if the line is not activated by the DTE: an active pull-up is enabled inside the module on the TxD input. CTS signal behavior The module hardware flow control output (CTS line) is set to the ON state (low level) at UART initialization. If the hardware flow control is enabled (for more details please refer to u-blox AT Commands Manual [2], AT&K, AT\Q, AT+IFC AT command) the CTS line indicates when the UART interface is enabled (data can be sent and received): the module drives the CTS line to the ON state or to the OFF state when it is either able or not able to accept data from the DTE (refer to chapter 1.9.2.3 for the complete description). If the hardware flow control is not enabled, the CTS line is always held in the ON state after UART initialization. In case of hardware flow control enabled, when CTS line is ON the UART is enabled and the module is in active mode. Instead, CTS line to OFF doesnt necessary mean that the module is in idle-mode, but only that the UART is not enabled (the module could be forced to stay in active-mode for instance by USB). When the power saving configuration is enabled and the hardware flow-control is not implemented in the DTE/DCE connection, data sent by the DTE can be lost: the first character sent when the module is in idle-mode wont be a valid communication character (refer to chapter 1.9.2.3 for the complete description). During the MUX mode, the CTS line state is mapped to FCon / FCoff MUX command for flow control issues outside the power saving configuration while the physical CTS line is still used as a power state indicator. For more details please refer to Mux Implementation Application Note [15]. RTS signal behavior The hardware flow control input (RTS line) is set by default to the OFF state (high level) at UART initialization. The RTS line is then held by the module in the OFF state if the line is not activated by the DTE: an active pull-up is enabled inside the module on the RTS input. If the HW flow control is enabled (for more details please refer to u-blox AT Commands Manual [2] AT&K, AT\Q, AT+IFC command description) the RTS line is monitored by the module to detect permission from the DTE to send data to the DTE itself. If the RTS line is set to OFF state, any on-going data transmission from the module is immediately interrupted or any subsequent transmission forbidden until the RTS line changes to ON state. The DTE must be able to still accept a certain number of characters after the RTS line has been set to OFF state: the module guarantees the transmission interruption within 2 characters from RTS state change. If AT+UPSV=2 is set and HW flow control is disabled, the RTS line is monitored by the module to manage the power saving configuration:
When an OFF-to-ON transition occurs on the RTS input line, the UART is enabled and the module is forced to active-mode; after 20 ms from the transition the switch is completed and data can be received without loss. The module cant enter idle-mode and the UART is keep enabled as long as the RTS input line is held in the ON state If RTS is set to OFF state by the DTE, the module automatically enters idle-mode whenever possible as in the AT+UPSV=1 configuration (cyclic idle/active mode), but UART is disabled (held in low power mode) For more details please refer to chapter 1.9.2.3 and u-blox AT Commands Manual [2], AT+UPSV command. 3G.G2-HW-10002-2 Advance Information System description Page 45 of 116 LISA-U1/LISA-H1 series - System Integration Manual DSR signal behavior If AT&S0 is set, the DSR module output line is set by default to ON state (low level) at UART initialization and is then always held in the ON state. If AT&S1 is set, the DSR module output line is set by default to OFF state (high level) at UART initialization. The DSR line is then set to the OFF state when the module is in command mode and is set to the ON state when the module is in data mode. The above behavior is valide for both Packet-Switched and Circuit-Switched Data transfer. DTR signal behavior The DTR module input line is set by default to OFF state (high level) at UART initialization. The DTR line is then held by the module in the OFF state if the line is not activated by the DTE: an active pull-up is enabled inside the module on the DTR input. Module behavior according to DTR status depends on the AT command configuration (see u-blox AT Commands Manual [2], &D AT command). DCD signal behavior If AT&C0 is set, the DCD module output line is set by default to ON state (low level) at UART initialization and is then always held in the ON state. If AT&C1 is set, the DCD module output line is set by default to OFF state (high level) at UART initialization. The DCD line is then set by the module in accordance with the carrier detect status: ON if the carrier is detected, OFF otherwise. In case of voice call DCD is set to ON state when the call is established. For a data call there are the following scenarios:
GPRS data communication: Before activating the PPP protocol (data mode) a dial-up application must provide the ATD*99***<context_number># to the module: with this command the module switches from command mode to data mode and can accept PPP packets. The module sets the DCD line to the ON state, then answers with a CONNECT to confirm the ATD*99 command. Please note that the DCD ON is not related to the context activation but with the data mode CSD data call: To establish a data call the DTE can send the ATD<number> command to the module which sets an outgoing data call to a remote modem (or another data module). Data can be transparent (non reliable) or non transparent (with the reliable RLP protocol). When the remote DCE accepts the data call, the module DCD line is set to ON and the CONNECT <communication baudrate> string is returned by the module. At this stage the DTE can send characters through the serial line to the data module which sends them through the network to the remote DCE attached to a remote DTE In case of a voice call DCD is set to ON state on all the serial communication interfaces supporting the AT command interface. (including MUX cirtual channels, if active). DCD is set to ON during the execution of a command requiring input data from the DTE (all the commands where a prompt is issued; see u-blox AT Commands Manual [2]). The DCD line is set to ON state as soon as the switch to binary/text input mode is completed and the prompt is issued; DCD line is set to OFF as soon as the input mode is interrupted or completed. RI signal behavior The RI module output line is set by default to the OFF state (high level) at UART initialization. Then, during an incoming call, the RI line is switched from OFF state to ON state with a 4:1 duty cycle and a 5 s period (ON for 1 s, OFF for 4 s, see Figure 22), until the DTE attached to the module sends the ATA string and the module accepts the incoming data call. The RING string sent by the module (DCE) to the serial port at constant time intervals is not correlated with the switch of the RI line to the ON state. 3G.G2-HW-10002-2 Advance Information System description Page 46 of 116 LISA-U1/LISA-H1 series - System Integration Manual Figure 22: RI behavior during an incoming call The RI line can notify an SMS arrival. When the SMS arrives, the RI line switches from OFF to ON for 1 s (see Figure 23), if the feature is enabled by the proper AT command (please refer to u-blox AT Commands Manual
[2], AT+CNMI command). RI OFF RI OFF RI ON RI ON 1s 1s 0 0 SMS arrives SMS Figure 23: RI behavior at SMS arrival time [s]
time [s]
This behavior allows the DTE to stay in power saving mode until the DCE related event requests service. In case of SMS arrival, if several events occur coincidently or in quick succession each event triggers the RI line independently, although the line will not be deactivated between each event. As a result, the RI line may stay to ON for more than 1 second. If an incoming call is answered within less than 1 second (with ATA or if autoanswering is set to ATS0=1) than the RI line will be set to OFF earlier. As a result:
RI line monitoring cant be used by the DTE to determine the number of received SMSes. In case of multiple events (incoming call plus SMS received), the RI line cant be used to discriminate the two events, but the DTE must rely on the subsequent URCs and interrogate the DCE with the proper commands. 1.9.2.3 UART and power-saving The power saving configuration is controlled by the AT+UPSV command (for the complete description please refer to u-blox AT Commands Manual [2], AT+UPSV command). When power saving is enabled, the module automatically enters idle-mode whenever possible, otherwise the active-mode is maintained by the module. The AT+UPSV command sets the module power saving configuration, but also configures the UART behavior in relation to the power saving configuration. The conditions for the module entering idle-mode also depend on the UART power saving configuration. The different power saving configurations that can be set by the AT+UPSV command are described in the following subchapters and are summarized in Table 19. For more details on the command description please refer to u-blox AT commands Manual [2]. 3G.G2-HW-10002-2 Advance Information System description Page 47 of 116 1stime [s]151050RI ONRI OFFCall incomes1stime [s]151050RI ONRI OFFCall incomes LISA-U1/LISA-H1 series - System Integration Manual AT+UPSV HW flow control RTS line Communication during idle mode and wake up 0 0 0 0 1 1 1 1 2 2 2 2 Enabled (AT&K3) Enabled (AT&K3) Disabled (AT&K0) Disabled (AT&K0) ON OFF ON OFF Enabled (AT&K3) ON Enabled (AT&K3) OFF Disabled (AT&K0) ON Disabled (AT&K0) OFF Enabled (AT&K3) Enabled (AT&K3) Disabled (AT&K0) ON OFF ON Disabled (AT&K0) OFF Data sent by the DTE will be correctly received by the module. Data sent by the module will be buffered by the module and will be correctly received by the DTE when it will be ready to receive data (i.e. RTS line will be ON). Data sent by the DTE will be correctly received by the module. Data sent by the module will be correctly received by the DTE if it is ready to receive data, otherwise data will be lost. Data sent by the DTE will be buffered by the DTE and will be correctly received by the module when active-mode is entered. Data sent by the module will be buffered by the module and will be correctly received by the DTE when it is ready to receive data (i.e. RTS line will be ON). If the module is in idle-mode, when a low-to-high transition occurs on the TxD input line, the module switches from idle-mode to active-mode after 20 ms: this is the wake up time of the module. As a consequence, the first character sent when the module is in idle-mode
(i.e. the wake up character) wont be a valid communication character because it cant be recognized, and the recognition of the subsequent characters is guaranteed only after the complete wake-up (i.e. after 20 ms). Data sent by the module will be correctly received by the DTE if it is ready to receive data, otherwise data will be lost. Not Applicable: HW flow control cannot be enabled with AT+UPSV=2. Not Applicable: HW flow control cannot be enabled with AT+UPSV=2. The module is forced in active-mode and it cant enter idle-mode until RTS line is set to OFF state. When a high-to-low (i.e. OFF-to-ON) transition occurs on the RTS input line, the module switches from idle-mode to active-mode after 20 ms: this is the wake up time of the module. When a low-to-high transition occurs on the TxD input line, the UART is re-enabled and if the module was in idle-mode it switches from idle-mode to active-mode after 20 ms: this is the wake up time of the module. As a consequence, the first character sent when the module is in idle-mode (i.e. the wake up character) wont be a valid communication character because it cant be recognized, and the recognition of the subsequent characters is guaranteed only after the complete wake-up (i.e. after 20 ms). Table 19: UART and power-saving summary AT+UPSV=0: power saving disabled, fixed active-mode The module doesnt enter idle-mode and the CTS line is always held in the ON state after UART initialization. The UART interface is enabled and data can be received. This is the default configuration. AT+UPSV=1: power saving enabled, cyclic idle/active mode The module is allowed to automatically enters idle-mode whenever possible, and periodically wakes up from idle-mode to active-mode to monitor the paging channel of the current base station (paging block reception), in accordance to GSM system requirements. Idle-mode time is fixed by network parameters and can be up to ~2.1 s. When the module is in idle-mode, a data transmitted by the DTE will be lost if hardware flow control is disabled, otherwise if hardware flow control is enabled, data will be buffered by the DTE and will be correctly received by the module when active-mode is entered. When the module wakes up to active-mode, the UART interface is enabled and data can be received. When a character is received, it forces the module to stay in the active-mode for a longer time. The active-mode duration depends by:
Network parameters, related to the time interval for the paging block reception (minimum of ~11 ms) Time period from the last data received at the serial port during the active-mode: the module doesnt enter idle-mode until a timeout expires. This timeout is configurable by the +UPSV AT command, from 40 GSM frames (~184 ms) up to 65000 GSM frames (300 s). Default value is 2000 GSM frames (~9.2 s) 3G.G2-HW-10002-2 Advance Information System description Page 48 of 116 LISA-U1/LISA-H1 series - System Integration Manual Every subsequent character received during the active-mode, resets and restarts the timer; hence the active-
mode duration can be extended indefinitely. The behavior of hardware flow-control output (CTS line) during normal module operations with power-saving and HW flow control enabled (cyclic idle-mode and active-mode) is illustrated in Figure 24. Data input CTS OFF CTS OFF CTS ON CTS ON max ~2.1 s max ~2.1 s UART disabled UART disabled min ~11 ms min ~11 ms UART enabled UART enabled
~9.2 s (default)
~9.2 s (default) UART enabled UART enabled time [s]
time [s]
Figure 24: CTS behavior with power saving enabled: the CTS line indicates when the module is able (CTS = ON = low level) or not able (CTS = OFF = high level) to accept data from the DTE and communicate through the UART interface AT+UPSV=2: power saving enabled and controlled by the RTS line If the RTS line is set to OFF by the DTE the module is allowed to enter the idle-mode as for UPSV=1 case. Instead, the UART is disabled as long as RTS line is set to OFF. If the RTS line is set to ON by the DTE the module is not allowed to enter the idle-mode and the UART is kept enabled until the RTS line is set to OFF. When an OFF-to-ON transition occurs on the RTS input line, the UART is re-enabled and the module switches from idle-mode to active-mode in 20 ms. This configuration can only be enabled with the module HW flow control disabled. When the RTS line is set to OFF by the DTE, the timeout to enter idle-mode from the last data received at the serial port during the active-mode is the one previously set with the AT+UPSV=1 configuration or it is the default value. Since HW flow control is disabled, the CTS line is always set to ON by the module. If the module has to transmit some data (e.g. URC), the UART is temporary enabled even if the RTS line is set to OFF; UART wake-up in case of RTS line set to OFF is also possible via data reception (as described in the following). If the USB is connected and active, the module is forced to stay in active-mode, therefore +UPSV=1 and
+UPSV=2 modes are overruled, but in any case they have effect on the UART behavior (they configure UART power saving mode (when it is enabled/disabled)). Wake up from idle-mode to active-mode via data reception If a data is transmitted by the DTE during the module idle-mode, it will be lost (not correctly received by the module) in the following cases:
+UPSV=1 with hardware flow control disabled
+UPSV=2 with hardware flow control disabled and RTS line set to OFF When the module is in idle-mode, the TxD input line of the module is always configured to wake up the module from idle-mode to active-mode via data reception: when a low-to-high transition occurs on the TxD input line, it causes the wake-up of the system. The module switches from idle-mode to active-mode in 20 ms from the first data reception: this is the wake up time of the module. As a consequence, the first character sent when the module is in idle-mode (i.e. the wake up character) wont be a valid communication character because it cant be 3G.G2-HW-10002-2 Advance Information System description Page 49 of 116 LISA-U1/LISA-H1 series - System Integration Manual recognized, and the recognition of the subsequent characters is guaranteed only after the complete wake-up
(i.e. after 20 ms). Figure 25 and Figure 26 show an example of common scenarios and timing constraints:
HW flow control set in the DCE, and no HW flow control set in the DTE, needed to see the CTS line changing on DCE Power saving configuration is active and the timeout from last data received to idle-mode start is set to 2000 frames (AT+UPSV=1,2000) Figure 25 shows the case where DCE is in idle mode and a wake-up is forced. In this scenario the only character sent by the DTE is the wake-up character; as a consequence, the DCE will return to idle-mode when the timeout from last data received expires. (2000 frames without data reception). Figure 25: Wake-up via data reception without further communication Figure 26 shows the case where in addition to the wake-up character further (valid) characters are sent. The wake up character wakes-up the DCE. The other characters must be sent after the wake up time of 20 ms. If this condition is satisfied, the characters are recognized by the DCE. The DCE is allowed to re-enter idle-mode after 2000 GSM frames from the latest data reception. Figure 26: Wake-up via data reception with further communication 3G.G2-HW-10002-2 Advance Information System description Page 50 of 116 CTS OFFCTSONActive mode is held for 2000 GSM frames (~9.2 s)time Wake up time: up to 15.6 mstime TxD module inputWake up character Not recognized by DCECTS OFFCTSONActive mode is held for 2000 GSM frames (~9.2s) after the last data receivedtime Wake up time: up to 15.6 mstime TxD module inputWake up character Not recognized by DCEValid characters Recognized by DCE LISA-U1/LISA-H1 series - System Integration Manual The wake-up via data reception feature cant be disabled. The wake-up via data reception feature can be used in both +UPSV=1 and +UPSV=2 case (when RTS line is set to OFF). In command mode, if HW flow control is not implemented by the DTE, the DTE must always send a dummy AT to the module before each command line: the first character will not be ignored if the module is in active-mode (i.e. the module will reply OK), or it will represent the wake up character if the module is in idle-mode (i.e. the module wont reply). No dummy AT is required from the DTE during connected-mode since the module continues to be in active-mode and doesnt need to be woken-up. Furthermore in data mode a dummy AT would affect the data communication. 1.9.2.4 UART application circuits Providing the full RS-232 functionality (using the complete V.24 link) For complete RS-232 functionality conforming to ITU Recommendation [3] in DTE/DCE serial communication, the complete UART interface of the module (DCE) must be connected to the DTE as described in Figure 27. Figure 27: Interface application circuit with complete V.24 link in DTE/DCE serial communication 3G.G2-HW-10002-2 Advance Information System description Page 51 of 116 LISA-U1/LISA-H1 series (DCE)TxDApplication Processor(DTE)RxDRTSCTSDTRDSRRIDCDGND15TXD12DTR16RXD13RTS14CTS9DSR10RI11DCDGND LISA-U1/LISA-H1 series - System Integration Manual Providing the TxD, RxD, RTS and CTS lines only (not using the complete V.24 link) If the functionality of the DSR, DCD, RI and DTR lines is not required in the application, or the lines are not available, the application circuit described in Figure 28 must be implemented:
Connect the module DTR input line to GND, since the module requires DTR active (low electrical level) Leave DSR, DCD and RI lines of the module unconnected and floating Figure 28: UART interface application circuit with partial V.24 link (5-wire) in the DTE/DCE serial communication If only TxD, RxD, RTS and CTS lines are provided as described in Figure 28 the procedure to enable the power saving depends on the HW flow-control status. If HW flow-control is enabled (AT&K3, that is the default setting) the power saving will be activated by AT+UPSV=1. Through this configuration, when the module is in idle-mode, a data transmitted by the DTE will be buffered by the DTE and will be correctly received by the module when active-mode is entered. If the HW flow-control is disabled (AT&K0), the power saving can be enabled by AT+UPSV=2. The module is in idle-mode until a high-to-low (i.e. OFF-to-ON) transition on the RTS input line will switch the module from idle-mode to active-mode in 20 ms. The module will be forced in active-mode if the RTS input line is held in the ON state. 3G.G2-HW-10002-2 Advance Information System description Page 52 of 116 LISA-U1/LISA-H1 series(DCE)TxDApplication Processor (DTE)RxDRTSCTSDTRDSRRIDCDGND15TXD12DTR16RXD13RTS14CTS9DSR10RI11DCDGND LISA-U1/LISA-H1 series - System Integration Manual Providing the TxD and RxD lines only (not using the complete V24 link) If the functionality of the CTS, RTS, DSR, DCD, RI and DTR lines is not required in the application, or the lines are not available, the application circuit described in Figure 29 must be implemented:
Connect the module CTS output line to the module RTS input line, since the module requires RTS active
(low electrical level) if HW flow-control is enabled (AT&K3, that is the default setting), and CTS is active (low electrical level) when the module is in active mode, the UART interface is enabled and the HW flow-control is enabled Connect the module DTR input line to GND, since the module requires DTR active (low electrical level) Leave DSR, DCD and RI lines of the module unconnected and floating Figure 29: UART interface application circuit with partial V.24 link (3-wire) in the DTE/DCE serial communication If only TxD and RxD lines are provided as described in Figure 29 and HW flow-control is disabled (AT&K0), the power saving will be enabled by AT+UPSV=1. The module enters active-mode 20 ms after a low-to-high transition on the TxD input line; the recognition of the subsequent characters is guaranteed until the module is in active-mode. A data delivered by the DTE can be lost using this configuration and the following settings:
o HW flow-control enabled in the module (AT&K3, that is the default setting) o Module power saving enabled by AT+UPSV=1 o HW flow-control disabled in the DTE In this case the first character sent when the module is in idle-mode will be a wake-up character and wont be a valid communication character (refer to chapter 1.9.1.3 for the complete description). If power saving is enabled the application circuit with the TxD and RxD lines only is not recommended. During command mode the DTE must send to the module a wake-up character or a dummy AT before each command line (refer to chapter 1.9.1.3 for the complete description), but during data mode the wake-up character or the dummy AT would affect the data communication. Additional considerations If the module USB interface of the is connected to the application processor, it is highly recommended to provide direct access to RxD, TxD, CTS and RTS lines of the module for execution of firmware upgrade over UART and for debug purpose: testpoints can be added on the lines to accommodate the access and a 0 series resistor must be mounted on each line to detach the module pin from any other connected device. Otherwise, if the USB interface is not connected to the application processor, it is highly recommended to provide direct access to VUSB_DET, USB_D+, USB_D- lines for execution of 3G.G2-HW-10002-2 Advance Information System description Page 53 of 116 LISA-U1/LISA-H1series(DCE)TxDApplication Processor (DTE)RxDRTSCTSDTRDSRRIDCDGND15TXD12DTR16RXD13RTS14CTS9DSR10RI11DCDGND LISA-U1/LISA-H1 series - System Integration Manual firmware upgrade over USB and for debug purpose. In both cases, provide as well access to RESET_N pin, or to the PWR_ON pin, or enable the DC supply connected to the VCC pin to start the module firmware upgrade (see Firmware Update Application Note [14]). If the UART interface is not used, all the UART interface pins can be left unconnected, but it is highly recommended to provide direct access to the RxD, TxD, CTS and RTS lines for execution of firmware upgrade and for debug purpose. 1.9.3 USB interface LISA-U1/LISA-H1 series modules provide a high-speed USB interface at 480 Mb/s compliant with the Universal Serial Bus Revision 2.0 specification [7]. It acts as a USB device and can be connected to any USB host such as a PC or other Application Processor. The USB-device shall look for all upper-SW-layers like any other serial device. This means that LISA-U1/LISA-H1 series modules emulate all serial control logical lines. If the logical DTR line isn't enabled by the USB host, the module doesnt answer to AT commands by the USB interface. Name Description VUSB_DET USB_D+
USB detect input USB Data Line D+
USB_D-
USB Data Line D-
Table 20: USB pins Remarks Apply 5 V typical to enable USB 90 nominal differential impedance. Pull-up or pull-down resistors and external series resistors as required by the USB 2.0 high-speed specification [7] are part of the USB pad driver and need not be provided externally. 90 nominal differential impedance. Pull-up or pull-down resistors and external series resistors as required by the USB 2.0 high-speed specification [7] are part of the USB pad driver and need not be provided externally. The USB interface pins ESD rating is 1 kV (contact discharge). A higher protection level could be required if the lines are externally accessible on the application board. A higher protection level can be achieved mounting a very low capacitance ESD protection (e.g. Tyco Electronics PESD0402-140 ESD protection device) on the lines connected to these pins. 1.9.3.1 USB features LISA-U1/LISA-H1 series modules simultaneously support 6 USB CDC (Communications Device Class) that assure multiple functionalities to the USB physical interface. The 6 available CDCs are configured as described in the following list:
USB1: AT commands / data connection USB2: AT commands / data connection USB3: AT commands / data connection USB4: GPS tunneling dedicated port USB5: 2G trace dedicated port USB6: 3G trace dedicated port LISA-U1/LISA-H1 series module identifies itself by its VID (Vendor ID) and PID (Product ID) combination, included in the USB device descriptor. VID and PID of LISA-U1/LISA-H1 series modules are the following:
VID = 0x1546 PID = 0x1101 3G.G2-HW-10002-2 Advance Information System description Page 54 of 116 LISA-U1/LISA-H1 series - System Integration Manual If the USB interface of LISA-U1/LISA-H1 series modules is connected to the host before the module switch-on, or if the module is reset with the USB interface connected to the host, the VID and PID are automatically updated runtime, after the USB detection. First, VID and PID are the following:
VID = 0x058B PID = 0x0041 Then, after a time period (~5 s), VID and PID are updated to the following:
VID = 0x1546 PID = 0x1101 If power saving is enabled by AT command (AT+UPSV=1 or AT+UPSV=2), the LISA-U1/LISA-H1 series module automatically enters the USB suspended state when the device has observed no bus traffic for a specified period
(refer to the Universal Serial Bus Revision 2.0 specification [7]). In suspended state, the module maintains any internal status as USB device, including its address and configuration. In addition, the module enters the suspended state when the hub port it is attached to is disabled: this is referred to as USB selective suspend. The module exits suspend mode when there is bus activity. LISA-U1/LISA-H1 series module is capable of USB remote wake-up signaling: may request the host to exit suspend mode or selective suspend by using electrical signaling to indicate remote wake-up. This notifies the host that it should resume from its suspended mode, if necessary, and service the external event that triggered the suspended USB device to signal the host. Remote wake-up is accomplished using electrical signaling described in the Universal Serial Bus Revision 2.0 specification [7]. 1.9.3.2 USB application circuit Since the module acts as a USB device, the USB supply (5.0 V typ.) must be provided to VUSB_DET by the connected USB host. The USB interface is enabled only when a valid voltage as USB supply is detected by the VUSB_DET input. Neither the USB interface, nor the whole module is supplied by the VUSB_DET input: the VUSB_DET senses the USB supply voltage and absorbs few microamperes. The USB_D+ and USB_D- lines carry the USB serial data and signaling. The lines are used in single ended mode for relatively low speed signaling handshake, as well as in differential mode for fast signaling and data transfer. USB pull-up or pull-down resistors on pins USB_D+ and USB_D- as required by the Universal Serial Bus Revision 2.0 specification [7] are part of the USB pad driver and do not need to be externally provided. External series resistors on pins USB_D+ and USB_D- as required by the Universal Serial Bus Revision 2.0 specification [7] are also integrated: characteristic impedance of USB_D+ and USB_D- lines is specified by the USB standard. The most important parameter is the differential characteristic impedance applicable for odd-mode electromagnetic field, which should be as close as possible to 90 differential: signal integrity may be degraded if the PCB layout is not optimal, especially when the USB signaling lines are very long. Figure 30: USB Interface application circuit 3G.G2-HW-10002-2 Advance Information System description Page 55 of 116 LISA-U1/LISA-H1 series VBUSD+D-GND18VUSB_DET27USB_D+26USB_D-GNDC1USB DEVICE CONNECTORD1D2D3 LISA-U1/LISA-H1 series - System Integration Manual Reference D1, D2, D3 C2 Description Part Number - Manufacturer Very Low Capacitance ESD Protection PESD0402-140 - Tyco Electronics 100 nF Capacitor Ceramic X7R 0402 10% 16 V GRM155R61A104KA01 - Murata Table 21: Component for USB application circuit If the USB interface is not connected to the application processor, it is highly recommended to provide direct access to the VUSB_DET, USB_D+, USB_D- lines for execution of firmware upgrade over USB and for debug purpose: testpoints can be added on the lines to accommodate the access. Otherwise, if the USB interface is connected to the application processor, it is highly recommended to provide direct access to the RxD, TxD, CTS and RTS lines for execution of firmware upgrade over UART and for debug purpose. In both cases, provide as well access to RESET_N pin, or to the PWR_ON pin, or enable the DC supply connected to the VCC pin to start the module firmware upgrade (see Firmware Update Application Note [14]). If the USB interface is not used, the USB_D+, USB_D- and VUSB_DET pins can be left unconnected, but it is highly recommended to provide direct access to the lines for execution of firmware upgrade and for debug purpose. 1.9.4 SPI interface SPI is a master-slave protocol: the module runs as an SPI slave, i.e. it accepts AT commands on its SPI interface without specific configuration. The SPI-compatible synchronous serial interface cannot be used for FW upgrade. The standard 3-wire SPI interface includes two signals to transmit and receive data (SPI_MOSI and SPI_MISO) and a clock signal (SPI_SCLK). LISA-U1/LISA-H1 series modules provide two handshake signals (SPI_MRDY and SPI_SRDY), added to the standard 3-wire SPI interface, implementing the 5-wire Inter Processor Communication (IPC) interface. The purpose of the IPC interface is to achieve high speed communication (up to 20 Mb/s) between two processors following the same IPC specifications: the module baseband processor and an external processor. The high speed communication is possible only if both sides follow the same Inter Processor Communication (IPC) specifications. This interface is designated for high speed HSPA communications and could be necessary to communicate with an Application Processor which is not equipped with a USB interface. 3G.G2-HW-10002-2 Advance Information System description Page 56 of 116 LISA-U1/LISA-H1 series - System Integration Manual Name SPI_MISO Description SPI Data Line. Master Input, Slave Output SPI_MOSI SPI Data Line. Master Output, Slave Input SPI_SCLK SPI Serial Clock. Master Output, Slave Input Remarks Module Output. Idle high. Shift data is on rising clock edge, latch on falling edge. MSB is shifted first. Module Input. Idle high. Shift data is on rising clock edge, latch on falling edge. MSB is shifted first. Internal active pull-up to V_INT (1.8 V) enabled. Module Input. Idle low. Up to 20 MHz supported. Internal active pull-down to GND enabled. Module Input. Idle low. Internal active pull-down to GND enabled. SPI_MRDY SPI_SRDY SPI Master Ready to transfer data control line. Master Output, Slave Input SPI Slave Ready to transfer data control line. Master Input, Slave Output Module Output. Idle low. Table 22: SPI interface signals The SPI interface pins ESD rating is 1 kV (contact discharge). A higher protection level could be required if the lines are externally accessible on the application board. A higher protection level can be achieved mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) on the lines connected to these pins. 1.9.4.1 IPC communication protocol overview The module runs as an SPI slave, i.e. it accepts AT commands on its SPI interface without specific configuration. The SPI-device shall look for all upper-SW-layers like any other serial device. This means that LISA-U1/LISA-H1 series modules emulate all serial logical lines: the transmission and the reception of the data are similar to an asynchronous device. Two additional signals (SPI_MRDY and SPI_SRDY) are added to the SPI lines to communicate the state of readiness of the two processors: they are used as handshake signals to implement the data flow. The function of the SPI_MRDY and SPI_SRDY signals is twofold:
For transmitting data the signal indicates to the data receiver that data is available to be transmitted For receiving data the signal indicates to the transmitter that the receiver is ready to receive data Due to this setup it is possible to use the control signals as interrupt lines waking up the receiving part when data is available for transfer. When the handshaking has taken place, the transfer occurs just as if it were a standard SPI interface without chip select functionality (i.e. one master - one slave setup). SPI_MRDY is used by the application processor (i.e. the master) to indicate to the module baseband processor
(i.e. the slave) that it is ready to transmit or receive (IPC master ready signal), and can also be used by the application processor to wake up the module baseband processor if it is in idle mode. SPI_SRDY line is used by the module baseband processor (i.e. the slave) to indicate to the application processor
(i.e. the master) that it is ready to transmit or receive (IPC slave ready signal), and can also be used by the module baseband processor to wake up the application processor if it is in hibernation. If power saving is enabled by AT command (AT+UPSV=1 or AT+UPSV=2), the LISA-U1/LISA-H1 series module automatically enters idle mode when the master indicates that it is not ready to transmit or receive by the SPI_MRDY signal, or when the LISA-U1/LISA-H1 series module itself doesnt transfer data. 3G.G2-HW-10002-2 Advance Information System description Page 57 of 116 LISA-U1/LISA-H1 series - System Integration Manual Figure 31: IPC Data Flow: SPI_MRDY and SPI_SRDY line usage combined with the SPI protocol For the correct implementation of the SPI protocol, the frame size is known by both sides before a packet transfer of each packet. The frame is composed by a header with fixed size (always 4 bytes) and a payload with variable length (must be a multiple of 4 bytes). The same amount of data is exchanged in both directions simultaneously. Both sides set their readiness lines
(SPI_MRDY / SPI_SRDY) independently when they are ready to transfer data. For the correct transmission of the data the other side must wait for the activating interrupt to allow the transfer of the other side. The master starts the clock shortly after SPI_MRDY and SPI_SRDY are set to active. The amount of clocks is exactly that one of the frame-size to be transferred. The SPI_SRDY line will be set down after the end of the clock. The SPI_MRDY line is also set inactive with the end of the clock, but in case of a big transfer containing multiple packets, the SPI_MRDY line stays active. 1.9.4.2 IPC communication examples In the following, three IPC communication scenarios are described:
Slave initiated data transfer, with a sleeping master Master initiated data transfer, with a sleeping slave Slave ended data transfer Slave initiated transfer with a sleeping master SPI_MRDY SPI_SRDY DATA EXCHG 2 1 3 Header Data 4 5 Header Figure 32: Data transfer initiated by LISA-U1/LISA-H1 series module (slave), with a sleeping application processor (master) When the master is sleeping (idle mode), the following actions happen:
1. The slave indicates the master that is ready to send data by activating SPI_SRDY 2. When the master becomes ready to send, it signalizes this by activating SPI_MRDY 3. The master activates the clock and the two processors exchange the communication header and data 3G.G2-HW-10002-2 Advance Information System description Page 58 of 116 SPI_MRDYSPI_SRDYDATA_EXCHANGESPI_MOSISPI_MISOHeader DataSPI_SCLK LISA-U1/LISA-H1 series - System Integration Manual 4. If the data have been exchanged, the slave deactivates SPI_SRDY to process the received information. The master does not need to de-assert SPI_MRDY as it controls the SPI_SCLK 5. After the preparation, the slave activates again SPI_SRDY and wait for SPI_SCLK activation. When the clock is active, all the data are transferred without intervention. If there is more data to transfer (flag set in any of the headers), the process will repeat from step 3 Master initiated transfer with a sleeping slave SPI_MRDY SPI_SRDY DATA EXCHG 2 3 1 4 5 Header Data Header Figure 33: Data transfer initiated by application processor (master) with a sleeping LISA-U1/LISA-H1 series module (slave) When the slave is sleeping (idle mode), the following actions happen:
1. The Master wakes the slave by setting the SPI_MRDY line active 2. As soon as the slave is awake, it signals it by activating SPI_SRDY 3. The master activates the clock and the two processors exchange the communication header and data 4. If the data have been exchanged, the slave deactivates SPI_SRDY to process the received information. The master does not need to de-assert SPI_MRDY as it controls the SPI_SCLK 5. After the preparation, the slave activates again SPI_SRDY and wait for SPI_SCLK activation. When the clock is active, all data are transferred without intervention. If there is more data to transfer (flag set in any of the headers), the process will repeat from step 3 Slave ended transfer SPI_MRDY SPI_SRDY 4 1 5 2 3 DATA EXCHG Header Data Figure 34: Data transfer terminated and then restarted by LISA-U1/LISA-H1 series module (slave) Starting from the state where data transfer is ongoing, the following actions will happen:
1. 2. In case of the last transfer, the master will lower its SPI_MRDY line. After the data-transfer is finished the line must be low. If the slave has already set its SPI_SRDY line, the master must raise its line to initiate the next transfer (slave-waking-procedure) If the data have been exchanged, the slave will deactivate SPI_SRDY to process the received information. This is the normal behavior 3. The slave will indicate the master that is ready to send data by activating SPI_SRDY 3G.G2-HW-10002-2 Advance Information System description Page 59 of 116 LISA-U1/LISA-H1 series - System Integration Manual 4. When the master is ready to send, it will signalize this by activating SPI_MRDY. This is optional, when SPI_MRDY is low before 5. The slave indicates immediately after a transfer termination that it wants to start transmission again. In this case the slave will raise SPI_SRDY again. The SPI_MRDY line can be either high or low: the master has only to ensure that the SPI_SRDY change will be detected correctly via interrupt For more details regarding IPC communication protocol please refer to SPI Application Note [18]. 1.9.4.3 IPC application circuit SPI_MOSI is the data line input for the module since it runs as SPI slave: it must be connected to the data line output (MOSI) of the application processor that runs as an SPI master. SPI_MISO is the data line output for the module since it runs as SPI slave: it must be connected to the data line input (MISO) of the application processor that runs as an SPI master. SPI_SCLK is the clock input for the module since it runs as SPI slave: it must be connected to the clock line output (SCLK) of the application processor that runs as an SPI master. SPI_MRDY is an input for the module able to detect an external interrupt which comes from the application processor. SPI_SRDY is an output for the module, and the application processor should be able to detect an external interrupt which comes from the module on its connected pin. Signal integrity of the high speed data lines may be degraded if the PCB layout is not optimal, especially when the SPI lines are very long: keep routing short and minimize parasitic capacitance to preserve signal integrity. Figure 35: IPC Interface application circuit If direct access to the USB or the UART interfaces of the module is not provided, it is recommended to provide direct access to the SPI_MOSI, SPI_MISO, SPI_SCLK, SPI_MRDY, SPI_SRDY lines of the module for debug purpose: testpoints can be added on the lines to accommodate the access and a 0 series resistor must be mounted on each line to detach the module pin from any other connected device. If the SPI/IPC interface is not used, the SPI_MOSI, SPI_MISO, SPI_SCLK, SPI_MRDY, SPI_SRDY pins can be left unconnected. 1.9.5 MUX Protocol (3GPP 27.010) The LISA-U1/LISA-H1 series module has a software layer with MUX functionality, 3GPP TS 27.010 Multiplexer Protocol [6], available on the UART and on the SPI physical link. This is a data link protocol (layer 2 of OSI model) which uses HDLC-like framing and operates between the module (DCE) and the application processor (DTE) and allows a number of simultaneous sessions over the used 3G.G2-HW-10002-2 Advance Information System description Page 60 of 116 LISA-U1/LISA-H1 series (SPI slave)MOSIApplication Processor(SPI master)MISOSCLKInterruptGPIOGND56SPI_MOSI59SPI_MRDY57SPI_MISO55SPI_SCLK58SPI_SRDYGND LISA-U1/LISA-H1 series - System Integration Manual physical link (UART or SPI). Each session consists of a stream of bytes transferring various kinds of data such as SMS, CBS, GPRS, GPS, AT commands in general. This permits, for example, SMS to be transferred to the DTE when a data connection is in progress. The following virtual channels are defined:
Channel 0: control channel Channel 1 5: AT commands /data connection Channel 6: GPS tunneling For more details please refer to GSM Mux implementation Application Note [15]. 1.10 DDC (I2C) interface 1.10.1 Overview An I2C compatible Display Data Channel (DDC) interface for serial communication is implemented. This interface is dedicated exclusively to access u-blox GPS receivers. Name SCL SDA Table 23: DDC pins Description I2C bus clock line I2C bus data line Remarks Open drain. External pull-up required. Open drain. External pull-up required. The DDC (I2C) interface pins ESD rating is 1 kV (contact discharge). A higher protection level could be required if the lines are externally accessible on the application board. A higher protection level can be achieved mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) on the lines connected to these pins. To be compliant to the I2C bus specifications, the module bus interface pads are open drain output and pull up resistors must be used. Since the pull-up resistors are not mounted on the module, they must be mounted externally. Resistor values must conform to the I2C bus specifications [8]. If a LISA-U1/LISA-H1 series module is connected through the DDC bus to a single u-blox GPS receiver only (only one device is connected on the DDC bus), use a pull-up resistor of 4.7 k. Pull-ups must be connected to a supply voltage of 1.8 V (typical), since this is the voltage domain of the DDC pins. V_INT digital interfaces supply output can be used to provide 1.8 V for the pull-ups (for detailed electrical characteristics see the LISA-U1/LISA-H1 series Data Sheet [1]). DDC Slave-mode operation is not supported, the module can act as master only. Two lines, serial data (SDA) and serial clock (SCL), carry information on the bus. SCL is used to synchronize data transfers, and SDA is the data line. Since both lines are open drain outputs, the DDC devices can only drive them low or leave them open. The pull-up resistor pulls the line up to the supply rail if no DDC device is pulling it down to GND. If the pull-ups are missing, SCL and SDA lines are undefined and the DDC bus will not work. The signal shape is defined by the values of the pull-up resistors and the bus capacitance. Long wires on the bus will increase the capacitance. If the bus capacitance is increased, use pull-up resistors with nominal resistance value lower than 4.7 k, to match the I2C bus specifications [8].regarding rise and fall times of the signals. Capacitance and series resistance must be limited on the bus to match the I2C specifications (1.0 s is the maximum allowed rise time on the SCL and SDA lines): route connections as short as possible.. If the pins are not used as DDC bus interface, they can be left unconnected. 3G.G2-HW-10002-2 Advance Information System description Page 61 of 116 LISA-U1/LISA-H1 series - System Integration Manual 1.10.2 DDC application circuit The SDA and SCL lines can be used only to connect the LISA module to a u-blox GPS module: LISA DDC (I2C) interface is enabled by the +UGPS AT command (for more details refer to u-blox AT Commands Manual [2]). GPIO2 is automatically driven as an output by the +UGPS AT command to switch-on or to switch-off the u-blox GPS module, connecting GPIO2 to the active-high enable pin (or the active-low shutdown pin) of the voltage regulator that supplies the u-blox GPS module on the application board. GPIO3 is automatically driven as an input by the +UGPS AT command to sense when the u-blox GPS module is ready to send data. GPIO4 is automatically driven as an output by the +UGPS AT command to provide a synchronization timing signal to the u-blox GPS module. The application circuit for the connection of a LISA-U1/LISA-H1 series wireless module to a u-blox 1.8 V GPS receiver is illustrated in Figure 36. A pull-down resistor is mounted on the GPIO2 line to avoid a switch on of the GPS module when the LISA-U1/LISA-H1 series module is in the internal reset state. Figure 36: DDC Application circuit for u-blox 1.8 V GPS receiver Reference R1, R2, R3 U1 Description Part Number - Manufacturer 4.7 k Resistor 0402 5% 0.1 W RC0402JR-074K7L - Yageo Phycomp Voltage Regulator for GPS Receiver See GPS Receiver Hardware Integration Manual Table 24: Components for DDC application circuit for u-blox 1.8 V GPS receiver If a 3 V u-blox GPS receiver is used, the SDA, SCL pins and the GPIO2, GPIO3, GPIO4 pins of the LISA-U1/LISA-H1 series wireless module cannot be directly connected to the 3 V u-blox GPS receiver, since the pins of the LISA-U1/LISA-H1 series modules arent tolerant up to 3 V. An application circuit for the connection of a LISA-U1/LISA-H1 series wireless module to a u-blox 3.0 V GPS receiver is illustrated in Figure 37. A pull-down resistor is mounted on the GPIO2 line to avoid a switch on of the GPS module when the LISA-U1/LISA-H1 series module is in the internal reset state. 3G.G2-HW-10002-2 Advance Information System description Page 62 of 116 LISA-U1/LISA-H1 seriesR1INOUTGNDGPS LDORegulatorSHDNu-blox1.8 V GPS receiverSDA2SCL2R21V81V8VMAIN1V8U121GPIO2SDASCLC1TxD1EXTINT0GPIO3GPIO446452324VCCR3 LISA-U1/LISA-H1 series - System Integration Manual Figure 37: DDC Application circuit for u-blox 3.0 V GPS receiver Reference Description Part Number - Manufacturer R1, R2, R3, R4, R5 4.7 k Resistor 0402 5% 0.1 W RC0402JR-074K7L - Yageo Phycomp C2, C3, C4, C5 100 nF Capacitor Ceramic X5R 0402 10% 10V GRM155R71C104KA01 - Murata U1 U2 U3 Voltage Regulator for GPS Receiver See GPS Receiver Hardware Integration Manual I2C-bus Bidirectional Voltage Translator PCA9306DCURG4 - Texas Instruments Generic Bidirectional Voltage Translator TXB0104PWR - Texas Instruments Table 25: Components for DDC application circuit for u-blox 3.0 V GPS receiver 1.11 Audio Interface (LISA-U120 and LISA-U130 only) LISA-U120 and LISA-U130 modules provide analog and digital audio interfaces:
One differential analog audio input (microphone input) One differential analog audio output (speaker output) One 4-wire I2S digital audio interface: input and output Audio signal routing can be controlled by the dedicated AT command +USPM (refer to u-blox AT Commands Manual [2]). This command allows setting the audio path mode, composed by the uplink audio path and the downlink audio path. 3G.G2-HW-10002-2 Advance Information System description Page 63 of 116 LISA-U1/LISA-H1 seriesR1INOUTGNDGPS LDORegulatorSHDNu-blox3.0 V GPS receiverR2VMAIN3V0U121GPIO246SDA45SCLR4R51V8SDA1 SDA2GNDU2SCL1SCL2VREF1VREF2I2C-busBidirectional Voltage Translator21V_INTC1C2C3R323GPIO324GPIO41V8A1 B1GNDU3A2B2VCCAVCCBGenericBidirectional Voltage TranslatorC4C53V0SDA2SCL2TxD1EXTINT0VCC LISA-U1/LISA-H1 series - System Integration Manual Each uplink path mode defines the physical input (i.e. the analog or the digital audio input) and the set of parameters to process the uplink audio signal (uplink gains, uplink digital filters, echo canceller parameters). For example the Headset microphone uplink path uses the differential analog audio input with the default parameters for the headset profile. Each downlink path mode defines the physical output (i.e. the analog or the digital audio output) and the set of parameters to process the downlink audio signal (downlink gains, downlink digital filters and sidetone). For example the Mono headset downlink path uses the differential analog audio output with the default parameters for the headset profile. The set of parameters to process the uplink or the downlink audio signal can be changed with dedicated AT commands for each uplink or downlink path and then stored in two profiles in the non volatile memory (refer to u-blox AT Commands Manual [2] for Audio parameters tuning commands). 1.11.1 Analog Audio interface 1.11.1.1 Uplink path (differential analog audio input) The pins related to the differential analog audio input are:
MIC_P / MIC_N: Differential analog audio signal inputs (positive/negative). These two pins are provided with internal series 100 nF capacitors for DC blocking that connect the module pads to the differential input of a Low Noise Amplifier. The LNA output is internally connected to the digital processing system by an integrated sigma-delta analog-to-digital converter The analog audio input is selected when the parameter <main_uplink> in AT+USPM command is set to Headset microphone, Handset microphone or Hands-free microphone: the uplink analog path profiles use the same physical input but have different sets of audio parameters (for more details please refer to u-blox AT Commands Manual [2], AT+USPM, AT+UMGC, AT+UUBF, AT+UHFP commands). There is no microphone supply pin available on the module: an external low noise LDO voltage regulator should be added to provide a proper supply for a microphone. Detailed electrical characteristics of the differential analog audio input can be found in the LISA-U1/LISA-H1 series Data Sheet [1]. 1.11.1.2 Downlink path (differential analog audio output) The pins related to the differential analog audio output are:
SPK_N / SPK_P: Differential analog audio signal output (positive/negative). These two pins are internally directly connected to the differential output of a low power audio amplifier, for which the input is internally connected to the digital processing system by to an integrated digital-to-analog converter. The analog audio output is selected when the parameter <main_downlink> in AT+USPM command is set to Normal earpiece, Mono headset or Loudspeaker: the downlink analog path profiles use the same physical output but have different sets of audio parameters (for more details please refer to u-blox AT Commands Manual [2], AT+USPM, AT+USGC, AT+UDBF, AT+USTN commands). The differential analog audio output can be directly connected to a headset earpiece or handset earpiece but is not able to drive an 8 speaker. Detailed electrical characteristics of the high power differential audio output can be found in the LISA-U1/LISA-H1 series Data Sheet [1]. Warning: excessive sound pressure from headphones can cause hearing loss. 3G.G2-HW-10002-2 Advance Information System description Page 64 of 116 LISA-U1/LISA-H1 series - System Integration Manual Table 26 lists the signals related to analog audio functions. Name MIC_P Description Remarks Differential analog audio input (Positive) MIC_N Differential analog audio input (Negative) SPK_P SPK_N Differential analog audio output (Positive) Differential analog audio output (Negative) Table 26: Analog Audio Signal Pins Shared for all uplink analog path modes: handset, headset, hands-free mode. Internal DC blocking capacitor. Shared for all uplink analog path modes: handset, headset, hands-free mode. Internal DC blocking capacitor. Shared for all uplink analog path modes: earpiece, headset, loudspeaker mode. Shared for all uplink analog path modes: earpiece, headset, loudspeaker mode. The audio pins ESD rating is 1 kV (contact discharge). A higher protection level could be required if the lines are externally accessible on the application board. A higher protection level can be achieved mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) on the lines connected to these pins. All corresponding differential audio lines must be routed in pairs, be embedded in GND (have the ground lines as close as possible to the audio lines), and maintain distance from noisy lines such as VCC and from components such as switching regulators. If the audio pins are not used, they can be left unconnected on the application board. 1.11.1.3 Headset mode Headset mode is the default audio operating mode of the LISA-U120 and LISA-U130 modules. The headset profile is configured when the uplink audio path is set to Headset microphone and the downlink audio path is set to Mono headset (refer to u-blox AT Commands Manual [2]: AT+USPM command: <main_uplink>,
<main_downlink> parameters):
Headset microphone must be connected to the module differential input MIC_P / MIC_N Headset receiver must be connected to the module differential output SPK_P / SPK_N Figure 38 shows an example of an application circuit connecting a headset (with a 2.2 k electret microphone and a 32 receiver) to the LISA-U120 and LISA-U130 modules, with an external low noise LDO voltage regulator to provide a proper supply for the microphone. Mount an 82 nH series inductor (e.g. Murata LQG15HS82NJ02) on each microphone line, and a 27 pF bypass capacitor (e.g. Murata GRM1555C1H270J) on all audio lines to minimize RF coupling and TDMA noise. The physical width of the audio outputs lines on the application board must be wide enough to minimize series resistance. 3G.G2-HW-10002-2 Advance Information System description Page 65 of 116 LISA-U1/LISA-H1 series - System Integration Manual Figure 38: Headset mode application circuit Reference Description Part Number - Manufacturer C1, C2, C3, C4 27 pF Capacitor Ceramic COG 0402 5% 25 V GRM1555C1H270JA01 - Murata C5, C6, C7 10 F Capacitor Ceramic X5R 0603 20% 6.3 V GRM188R60J106ME47 - Murata D1, D2 L1, L2 J1 Low Capacitance ESD Protection 82 nH Multilayer inductor 0402
(self resonance frequency ~1 GHz) USB0002RP or USB0002DP - AVX LQG15HS82NJ02 - Murata Audio Headset 2.5 mm Jack Connector SJ1-42535TS-SMT CUI, Inc. R1, R2, R3, R4 2.2 k Resistor 0402 5% 0.1 W RC0402JR-072K2L - Yageo Phycomp U1 Low Noise LDO Linear Regulator 2.5 V 300 mA LT1962EMS8-2.5#PBF- Linear Technology Table 27: Example of components for headset jack connection 1.11.1.4 Handset mode The handset profile is configured when the uplink audio path is set to Handset microphone and the downlink audio path is set to Normal earpiece (refer to u-blox AT commands manual [2]: AT+USPM command:
<main_uplink>, <main_downlink> parameters):
Handset microphone must be connected to the module differential input MIC_P / MIC_N Handset receiver must be connected to the module differential output SPK_P / SPK_N Figure 39 shows an example of an application circuit connecting a handset (with a 2.2 k electret microphone and a 32 receiver) to the LISA-U120 and LISA-U130 modules, with an external low noise LDO voltage regulator to provide a proper supply for the microphone. Mount an 82 nH series inductor (e.g. Murata LQG15HS82NJ02) on each microphone line and a 27 pF bypass capacitor (e.g. Murata GRM1555C1H270J) on all audio lines to minimize RF coupling and TDMA noise. The physical width of the audio outputs lines on the application board must be wide enough to minimize series resistance. 3G.G2-HW-10002-2 Advance Information System description Page 66 of 116 LISA-U120/U130C2C3C4J1253461L254SPK_N53SPK_P39MIC_N40MIC_PD1AUDIO HEADSET CONNECTORD2INOUTGNDLow Noise LDO RegulatorVMAINU1R4R1C6R3R2C52V5Sense lines connected to GND in one star pointL1C1C7 LISA-U1/LISA-H1 series - System Integration Manual Figure 39: Handset mode application circuit Reference Description Part Number - Manufacturer C1, C2, C3, C4 27 pF Capacitor Ceramic COG 0402 5% 25 V GRM1555C1H270JA01 - Murata C5, C6, C7 10 F Capacitor Ceramic X5R 0603 20% 6.3 V GRM188R60J106ME47 - Murata D1, D2 L1, L2 J1 Low Capacitance ESD Protection 82nH Multilayer inductor 0402
(self resonance frequency ~1 GHz) USB0002RP or USB0002DP - AVX LQG15HS82NJ02 - Murata Audio Handset Jack Connector, 4Ckt (4P4C) 52018-4416 - Molex R1, R2, R3, R4 2.2 k Resistor 0402 5% 0.1 W RC0402JR-072K2L - Yageo Phycomp U1 Low Noise LDO Linear Regulator 2.5 V 300 mA LT1962EMS8-2.5#PBF- Linear Technology Table 28: Example of components for handset connection 1.11.1.5 Hands-free mode The hands-free profile is configured when the uplink audio path is set to Hands-free microphone and the downlink audio path is set to Loudspeaker (refer to u-blox AT commands manual [2]: AT+USPM command:
<main_uplink>, <main_downlink> parameters):
Hands-free microphone signal must be connected to the module differential input MIC_P / MIC_N High power loudspeaker must be connected to the output of an external audio amplifier, for which the input must be connected to the module differential output SPK_P / SPK_N The module differential analog audio output is not able to drive an 8 speaker: an external audio amplifier must be provided on the application board to amplify the low power audio signal provided by the module differential output SPK_P / SPK_N. Hands-free functionality is implemented using appropriate digital signal processing algorithms for voice-band handling (echo canceller and automatic gain control), managed via software (refer to u-blox AT commands manual [2], AT+UHFP command). Figure 39 shows an example of an application circuit connecting a 2.2 k electret microphone and an 8 speaker to the LISA-U120 and LISA-U130 modules, with an external low noise LDO voltage regulator to provide a proper supply for the microphone and with an external audio amplifier to amplify the low power audio signal provided by the module differential output. 3G.G2-HW-10002-2 Advance Information System description Page 67 of 116 LISA-U120/U130C1C2C3J14321L153SPK_P54SPK_N40MIC_P39MIC_ND1AUDIO HANDSET CONNECTORD2INOUTGNDLow Noise LDO RegulatorU1R4R1C6R3R2C52V5Sense lines connected to GND in one star pointC4L2VMAINC7 LISA-U1/LISA-H1 series - System Integration Manual Mount an 82 nH series inductor (e.g. Murata LQG15HS82NJ02) on each microphone line and a 27 pF bypass capacitor (e.g. Murata GRM1555C1H270J) on all audio lines to minimize RF coupling and TDMA noise. The physical width of the audio outputs lines on the application board must be wide enough to minimize series resistance. Figure 40: Hands-free mode application circuit Reference Description Part Number - Manufacturer C1, C2, C3, C4 27 pF Capacitor Ceramic COG 0402 5% 25 V GRM1555C1H270JZ01 - Murata C5, C6, C7, C10 10 F Capacitor Ceramic X5R 0603 20% 6.3 V GRM188R60J106ME47 - Murata 47 nF Capacitor Ceramic X7R 0402 10% 16V GRM155R71C473KA01 - Murata 100 nF Capacitor Ceramic X5R 0402 10% 10V GRM155R71C104KA01 - Murata Low Capacitance ESD Protection USB0002RP or USB0002DP - AVX Microphone Connector Speaker Connector 82nH Multilayer inductor 0402
(self resonance frequency ~1 GHz) 2.2 k Electret Microphone 0 Resistor 0402 5% 0.1 W 8 Loudspeaker R1, R2, R3, R4 2.2 k Resistor 0402 5% 0.1 W LQG15HS82NJ02 - Murata RC0402JR-072K2L - Yageo Phycomp RC0402JR-070RL - Yageo Phycomp Low Noise LDO Linear Regulator 2.5 V 300 mA LT1962EMS8-2.5#PBF- Linear Technology Filter-less Mono 2.8 W Class-D Audio Amplifier SSM2305CPZ - Analog Devices C8, C9 C11 D1, D2 J1 J2 L1, L2 MIC R5, R6 SPK U1 U2 Table 29: Example of components for hands-free connection 3G.G2-HW-10002-2 Advance Information System description Page 68 of 116 C1C2C3L139MIC_N53SPK_P40MIC_P54SPK_ND1Microphone ConnectorD2INOUTGNDLow Noise LDO RegulatorU1R4R1C6R3R2C52V5Sense lines connected to GND in one star pointC4SPKL2MICSpeaker ConnectorOUT+IN+GNDVMAINU2OUT-IN-C8C9R5R6VDDC11C10LISA-U120/U130Audio AmplifierJ1J2VMAINC7 LISA-U1/LISA-H1 series - System Integration Manual 1.11.1.6 Connection to an external analog audio device The differential analog audio input / output can be used to connect the module to an external analog audio device. Audio devices with a differential analog input / output are preferable, as they are more immune to external disturbances. If the external analog audio device is provided with a differential analog audio input, the SPK_P / SPK_N balanced output of the module must be connected to the differential input of the external audio device through a DC-block 10 F series capacitor (e.g. Murata GRM188R60J106M) to decouple the bias present at the module output (see SPK_P / SPK_N common mode output voltage in the LISA-U1/LISA-H1 series Data Sheet [1]). Use a suitable power-on sequence to avoid audio bump due to charging of the capacitor: the final audio stage should be always enabled as last one. If the external analog audio device is provided with a single ended analog audio input, a proper differential to single ended circuit must be inserted from the SPK_P / SPK_N balanced output of the module to the single ended input of the external audio device. A simple application circuit is described in Figure 41: 10 F series capacitors (e.g. Murata GRM188R60J106M) are provided to decouple the bias present at the module output, and a voltage divider is provided to properly adapt the signal level from the module output to the external audio device input. The DC-block series capacitor acts as high-pass filter for audio signals, with cut-off frequency depending on both the values of capacitor and on the input impedance of the external audio device. For example: in case of differential input impedance of 600 , the two 10 F capacitors will set the -3 dB cut-off frequency to 53 Hz, while for single ended connection to 600 external device, the cut-off frequency with just the single 10 F capacitor will be 103 Hz. In both cases the high-pass filter has a low enough cut-off to not impact the audio signal frequency response. The signal levels can be adapted by setting gain using AT commands, but additional circuitry must be inserted if the SPK_P / SPK_N output level of the module is too high for the input of the audio device. If the external analog audio device is provided with a differential analog audio output, the MIC_P / MIC_N balanced input of the module must be connected directly to the differential output of the external audio device. Series capacitors are not needed since MIC_P / MIC_N pins are provided with internal 100 nF capacitors for DC blocking (see LISA-U1 series Data Sheet [1]). If the external analog audio device is provided with a single ended analog audio output, a proper single ended to differential circuit has to be inserted from the single ended output of the external audio device to the MIC_P / MIC_N balanced input of the module. A simple application circuit is described in Figure 41: a voltage divider is provided to properly adapt the signal level from the external audio device output to the module input. The signal levels can be adapted by setting gain using AT commands, but additional circuitry must be inserted if the output level of the audio device is too high for MIC_P / MIC_N. Please refer to Figure 41 for the application circuits. To enable the audio path corresponding to the differential analog audio input / output, please refer to u-blox AT Commands Manual [2]: AT+USPM command. To tune audio levels for the external device please refer to u-blox AT Commands Manual [2] (AT+USGC, AT+UMGC commands). 3G.G2-HW-10002-2 Advance Information System description Page 69 of 116 LISA-U1/LISA-H1 series - System Integration Manual Figure 41: Application circuits to connect the module to audio devices with proper differential or single-ended input/output Reference Description Part Number - Manufacturer C1, C2, C3, C4 10 F Capacitor X5R 0603 5% 6.3 V GRM188R60J106M - Murata R1, R3 R2, R4 0 Resistor 0402 5% 0.1 W RC0402JR-070RL - Yageo Phycomp Not populated Table 30: Connection to an Audio Device 1.11.2 Digital Audio interface LISA-U120 and LISA-U130 modules support a bidirectional 4-wire I2S digital audio interface. The module acts as master only. The applicable pins are described in Table 31:
Name I2S_WA I2S_TXD I2S_CLK I2S_RXD Description I2S word alignment I2S transmit data I2S clock I2S receive data Table 31: I2S interface pins Remarks Module output (master) Module output Module output (master) Module input The I2S interface pins ESD rating is 1 kV (contact discharge). A higher protection level could be required if the lines are externally accessible on the application board. A higher protection level can be achieved mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) on the lines connected to these pins. 3G.G2-HW-10002-2 Advance Information System description Page 70 of 116 LISA-U120/U130C1C254SPK_N53SPK_PGND40MIC_PGNDNegative Analog INPositive Analog INNegative Analog OUTPositive Analog OUTAudio DeviceReferenceReference39MIC_NLISA-U120/U13054SPK_N53SPK_PGND40MIC_PGNDAnalog INAudio DeviceReferenceReference39MIC_NAnalog OUTC3C4R2R1R4R3 LISA-U1/LISA-H1 series - System Integration Manual If the I2S digital audio pins are not used, they can be left unconnected on the application board. The I2S interface can be can be used in two modes:
PCM mode Normal I2S mode To select the I2S digital audio interface the AT+USPM command parameters must assume these values (for more details please refer to u-blox AT Commands Manual [2]):
<main_uplink>: I2S input line
<main_downlink>: I2S output line Parameters of digital path can be configured and saved as the normal analog paths, using appropriate path parameter as described in the u-blox AT Commands Manual [2], +USGC, +UMGC, +USTN AT command. Analog gain parameters of microphone and speakers are unused when digital path is selected. I2S_TX and I2S_RX are respectively parallel to the analog front end, so resources available for analog path can be shared:
Digital filters and digital gains are available in both uplink and downlink direction. Configure using AT commands Ringer tone and service tone are mixed on the TX path when active (downlink) The HF algorithm acts on I2S path Refer to the u-blox AT Commands Manual [2]: AT+UI2S command for possible combinations of connection and settings. 1.11.2.1 I2S interface - PCM mode Main features of the I2S interface in PCM mode:
I2S runs in PCM - short alignment mode (configurable by AT commands) Module functions as I2S master (I2S_CLK and I2S_WA signals generated by the module) I2S_WA signal always runs at 8 kHz I2S_WA toggles high for 1 or 2 CLK cycles of synchronization (configurable), then toggles low for 16 CLK cycles of sample width. Frame length can be 1 + 16 = 17 bits or 2 + 16 = 18 bits I2S_CLK frequency depends on frame length. Can be 17 x 8 kHz = 136 kHz or 18 x 8 kHz = 144 kHz I2S_TX, I2S_RX data are 16 bit words with 8 kHz sampling rate, mono. Data is in 2s complement notation. MSB is transmitted first When I2S_WA toggles high, the first synchronization bit is always low. Second synchronization bit (present only in case of 2 bit long I2S_WA configuration) is MSB of the transmitted word (MSB is transmitted twice in this case) I2S_TX changes on I2S_CLK rising edge, I2S_RX changes on I2S_CLK falling edge 1.11.2.2 I2S interface - Normal I2S mode Normal I2S supports:
16 bits word Mono interface 8 kHz frequency Main features of I2S interface in normal I2S mode:
3G.G2-HW-10002-2 Advance Information System description Page 71 of 116 LISA-U1/LISA-H1 series - System Integration Manual I2S_WA signal always runs at 8 kHz and synchronizes 2 channels (timeslots on WA high, WA low) I2S_TX data are composed of 16 bit words, dual mono (the words are written on both channels). Data are in 2s complement notation. MSB is transmitted first. The bits are written on I2S_CLK rising or falling edge
(configurable) I2S_RX data are read as 16 bit words, mono (words are read only on the timeslot with WA high). Data is read in 2s complement notation. MSB is read first. The bits are read on the I2S_CLK edge opposite to I2S_TX writing edge (configurable) I2S_CLK frequency is 16 bits x 2 channels x 8 kHz = 256 kHz The modes are configurable through a specific AT command (refer to the related chapter in u-blox AT Commands Manual [2], +UI2S AT command) and the following parameters can be set:
MSB can be 1 bit delayed or non-delayed on I2S_WA edge I2S_TX data can change on rising or falling edge of I2S_CLK signal (rising edge in this example) I2S_RX data are read on the opposite front of I2S_CLK signal 1.11.3 Voiceband processing system The voiceband processing on the LISA-U120 and LISA-U130 modules is implemented in the DSP core inside the baseband chipset. The analog audio front-end of the chipset is connected to the digital system through 16 bit ADC converters in the uplink path, and through 16 bit DAC converters in the downlink path. External digital audio devices can be interfaced directly to the DSP digital processing part via the I2S digital interface. The analog amplifiers are skipped in this case. Possible processing of audio signal are:
Speech encoding (uplink) and decoding (downlink).The following speech codecs are supported in firmware on the DSP:
Fullrate, enhanced full rate, and half rate speech encoding and decoding Adaptive multi rate (full rate and half rate) speech encoding and decoding Mandatory sub-functions:
Discontinuous transmission, DTX (GSM 46.031, 46.041, 46.081 and 46.093 standards) Voice activity detection, VAD (GSM 46.032, 46.042, 46.082 and 46.094 standards) Background noise calculation (GSM 46.012, 46.022, 46.062 and 46.092 standards) Function configurable via specific AT commands (refer to the u-blox AT Commands Manual [2]) Signal routing: +USPM command Analog amplification, Digital amplification: +USGC,+CLVL, +CRSL, +CMUT command Digital filtering: +UUBF, +UDBF commands Hands-free algorithms (echo cancellation, Noise suppression, Automatic Gain control) +UHFP command Sidetone generation (feedback of uplink speech signal to downlink path): +USTN command Playing/mixing of alert tones:
Service tones: Tone generator with 3 sinus tones +UPAR command User generated tones: Tone generator with 3 sinus tones +UTGN command Midi melodies (for ringer): Synthesizer with up to 64 voices and a 48 kHz sampling rate, +UPAR command AMR files (for prompting): The storage format of AMR encoded audio content is defined in RFC3267 chapter 5 [9], +UPLAYFILE command With exception of the speech encoder/decoder, this audio processing can be controlled by AT commands. This processing is implemented within three different blocks of the voiceband processing system:
3G.G2-HW-10002-2 Advance Information System description Page 72 of 116 LISA-U1/LISA-H1 series - System Integration Manual Sample-based Voice-band Processing (single sample processed at 8 kHz, every 125 s) Frame-based Voice-band Processing (frames of 160 samples are processed every 20 ms) MIDI synthesizer running at 47.6 kHz These three blocks are connected by buffers (circular buffer and voiceband sample buffer) and sample rate converters (for 8 to 47.6 kHz conversion) as illustrated in the block diagram in Figure 42, which summarizes the voiceband audio processing in the DSP. Figure 42: Voiceband processing system block diagram 3G.G2-HW-10002-2 Advance Information System description Page 73 of 116 DACADCI2S_RXDSwitchMICMicrophone Analog GainUplink filter 2Uplink filter 1Hands-freeTo Radio TXScal_MicDigital GainSidetoneDownlink filter 1Downlink filter 2MIDI playerSPK_P/NSwitchI2S_TXDScal_Rec Digital GainMix_AFE Digital GainSPK Analog_gainGain_out Digital GainTone GeneratorFrom Radio RXSpeech levelI2Sx RXSample Based ProcessingFrame Based ProcessingAMR PlayerCircular bufferVoiceband Sample Buffer18 dBPower Amplifier LISA-U1/LISA-H1 series - System Integration Manual 1.12 General Purpose Input/Output (GPIO) The LISA-U1/LISA-H1 series modules provide 5 pins (GPIO1, GPIO2, GPIO3, GPIO4 and GPIO5) which can be configured as general purpose input or output, or can be configured to provide special functions via u-blox AT commands (for further details refer to u-blox AT Commands Manual [2], +UGPIOC, +UGPIOR, +UGPIOW,
+UGPS, +UGPRF). The available functions are described below:
GSM Tx burst indication: the GPIO1 can be configured by AT+UGPIOC to indicate when a GSM Tx burst/slot occurs. The pin can be connected on the application board to an input pin of an application processor to indicate when a GSM Tx burst/slot occurs GPS supply enable: the GPIO2 is by default configured to enable or disable the supply of the u-blox GPS receiver connected to the LISA-U1/LISA-H1 series module. The pin must be connected to the active-high enable pin (or the active-low shutdown pin) of the voltage regulator that supplies the u-blox GPS receiver on the application board. The pin is automatically set output high to switch on the u-blox GPS receiver when the parameter <mode> of +UGPS AT command is set to 1, and otherwise it is set in tri-state with an internal active pull-down enabled. The GPIO1, GPIO3, GPIO4 or GPIO5 can be configured by AT+UGPIOC to provide this feature, alternatively to the default GPIO2 GPS data ready: the GPIO3 is by default configured to sense when the u-blox GPS receiver connected to the LISA-U1/LISA-H1 series module is ready to send data by the DDC (I2C) interface. The pin must be connected to the data ready output of the u-blox GPS receiver (i.e. the pin TxD1 of the u-blox GPS module) on the application board. The pin automatically senses the line status to wake up the LISA-U1/LISA-H1 series module from idle mode if the u-blox GPS receiver is ready to send data by the DDC (I2C) interface, when the parameter <mode> of +UGPS AT command is set to 1, and otherwise it is set in tri-state with an internal active pull-down enabled GPS aiding synch: the GPIO4 is by default configured to provide a synchronization timing signal to the u-blox GPS receiver connected to the LISA-U1/LISA-H1 series module. The pin must be connected to the synchronization timing input of the u-blox GPS receiver (i.e. the pin EXTINT0 of the u-blox GPS module) on the application board. The pin automatically provides a synchronization timing signal to the u-blox GPS receiver when the parameter <mode> of +UGPS AT command is set to 1, and otherwise it is set in tri-state with an internal active pull-down enabled SIM card detection: the GPIO5 is by default configured to detect SIM card presence. The pin must be connected on the application board to the SW2 pin of the SIM card connector with a 470 k pull-down resistor and SW1 pin of the SIM card connector must be pulled up to the module V_INT by a 1 k pull-up resistor Network status indication: each GPIO (GPIO1, GPIO2, GPIO3, GPIO4 or GPIO5) can be configured by AT+UGPIOC to indicate network status (registered home network, registered roaming, data transmission, no service). The pin configured to provide this feature can be connected on the application board to an input pin of an application processor or can drive a LED by a transistor with integrated resistors to indicate network status General purpose input: all the GPIOs (GPIO1, GPIO2, GPIO3, GPIO4 and GPIO5) can be configured by AT+UGPIOC as input, sensing high or low digital level by AT+UGPIOR General purpose output: all the GPIOs (GPIO1, GPIO2, GPIO3, GPIO4 and GPIO5) can be configured by AT+UGPIOC as output, set in the high or low digital level by AT+UGPIOW, sensing high or low digital level by AT+UGPIOR Pad disabled: all the GPIOs (GPIO1, GPIO2, GPIO3, GPIO4 and GPIO5) can be configured by AT+UGPIOC in tri-state, with an internal active pull-down enabled 3G.G2-HW-10002-2 Advance Information System description Page 74 of 116 Name GPIO1 LISA-U1/LISA-H1 series - System Integration Manual Description Remarks GPIO By default, any function is disabled and the internal active pull-down is enabled. Can be alternatively configured by the AT+UGPIOC command to provide the Output function to provide the Input function to provide the Network Status Indication function to provide the GPS Supply Enable function to provide the GSM Tx Burst Indication function By default, the pin is configured to provide the GPS Supply Enable function. Can be alternatively configured by the AT+UGPIOC command to provide the Output function to provide the Input function to provide the Network Status Indication function to disable any function and enable the internal active pull-down By default, the pin is configured to provide the GPS Data Ready function. Can be alternatively configured by the AT+UGPIOC command to provide the Output function to provide the Input function to provide the Network Status Indication function to provide the GPS Supply Enable function to disable any function and enable the internal active pull-down By default, the pin is configured to provide the GPS Aiding Synch function. Can be alternatively configured by the AT+UGPIOC command to provide the Output function to provide the Input function to provide the Network Status Indication function to provide the GPS Supply Enable function to disable any function and enable the internal active pull-down By default, the pin is configured to provide the SIM card detection function. Can be alternatively configured by the AT+UGPIOC command to provide the Output function to provide the Input function to provide the Network Status Indication function to provide the GPS Supply Enable function to disable any function and enable the internal active pull-down GPIO2 GPIO GPIO3 GPIO GPIO4 GPIO GPIO5 GPIO Table 32: GPIO pins The GPIO pins ESD rating is 1 kV (contact discharge). A higher protection level could be required if the lines are externally accessible on the application board. A higher protection level can be achieved mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array) on the lines connected to these pins. An application circuit for a typical GPIO usage (GPS supply enable, GPS aiding synch, GPS data ready, SIM card detection, Network indication) is described in Figure 43. Use transistors with at least an integrated resistor in the base pin or otherwise put a 10 k resistor on the board in series to the GPIO. 3G.G2-HW-10002-2 Advance Information System description Page 75 of 116 LISA-U1/LISA-H1 series - System Integration Manual Figure 43: GPIO application circuit Reference Description Part Number - Manufacturer R1 U1 R2 R3 D1 J1 R4 R5 R6 DL1 T1 4.7 k Resistor 0402 5% 0.1 W Various manufacturers Voltage Regulator for GPS Receiver See GPS Module Hardware Integration Manual 1 k Resistor 0402 5% 0.1 W 470 k Resistor 0402 5% 0.1 W ESD Transient Voltage Suppressor SIM Card Holder 10 k Resistor 0402 5% 0.1 W 47 k Resistor 0402 5% 0.1 W 820 Resistor 0402 5% 0.1 W LED Red SMT 0603 NPN BJT Transistor Various manufacturers Various manufacturers USB0002RP or USB0002DP - AVX Various Manufacturers, CCM03-3013LFT R102 - C&K Components Various manufacturers Various manufacturers Various manufacturers LTST-C190KRKT - Lite-on Technology Corporation BC847 - Infineon Table 33: Components for GPIO application circuit If the GPIO pins are not used, they can be left unconnected on the application board. 3G.G2-HW-10002-2 Advance Information System description Page 76 of 116 SIM card holderSW1 SW2 4V_INT51GPIO5R3R2OUTINGNDLDO RegulatorSHDN3V81V8GPIO3GPIO4TxD1EXTINT02324R1VCCGPIO221LISA-U1/LISA-H1 seriesu-blox1.8 V GPS receiverU1J1C1R4R63V8Network IndicatorR5GPS Supply EnableGPS Data ReadyGPS Aiding SynchSIM Detection20GPIO1DL1T1D1 LISA-U1/LISA-H1 series - System Integration Manual 1.13 Reserved pins (RSVD) LISA-U1/LISA-H1 series modules have some pins reserved for future use. All the RSVD pins, except pin number 5, can be left unconnected on the application board. The application circuit is illustrated in Figure 44. Pin 5 (RSVD) must be connected to GND. Figure 44: Application circuit for the reserved pins (RSVD) 3G.G2-HW-10002-2 Advance Information System description Page 77 of 116 LISA-U120/U1305RSVD52RSVD74RSVDLISA-U100/U110 LISA-H100/H1105RSVD52RSVD74RSVD39RSVD40RSVD41RSVD42RSVD43RSVD44RSVD53RSVD53RSVD LISA-U1/LISA-H1 series - System Integration Manual 1.14 Schematic for LISA-U1/LISA-H1 series module integration Figure 45 is an example of a schematic diagram where a LISA-U1/LISA-H1 series module is integrated into an application board, using all the interfaces of the module. Figure 45: Example of schematic diagram to integrate LISA module in an application board, using all the interfaces 3G.G2-HW-10002-2 Advance Information System description Page 78 of 116 47pFSIM Card HolderCCVCC (C1)CCVPP (C6)CCIO (C7)CCCLK (C3)CCRST (C2)GND (C5)47pF47pF100nF50VSIM48SIM_IO47SIM_CLK49SIM_RST47pFSW1 SW24V_INT51GPIO5470k1kESDESDESDESDESDESDTXDRXDRTSCTSDTRDSRRIDCDGND15TXD12DTR16RXD13RTS14CTS9DSR10RI11DCDGND3V8330F39pFGND10nF100nF10pFLISA-U1/LISA-H1 series62VCC63VCC61VCC+100F2V_BCKPMOSIMISOSCLKInterruptGPIOGND56SPI_MOSI59SPI_MRDY57SPI_MISO55SPI_SCLK58SPI_SRDYGNDVBUSD+D-GND18VUSB_DET27USB_D+26USB_D-GND100nF5RSVD52RSVD74RSVDGNDRTC back-up27pF27pF27pF82nH54SPK_N53SPK_P39MIC_N40MIC_PESDHeadset ConnectorESDINOUTGNDLow Noise LDO Regulator3V82.2k2.2k10F2.2k2.2k10F2V5Sense lines connected to GND in one star point82nH27pF10FESDESDu-blox1.8V GPS Receiver4.7kOUTINGNDLDO RegulatorSHDNSDASCL4.7k3V81V8_GPSSDA2SCL2GPIO3GPIO4TxD1EXTINT0464523244.7kVCCGPIO221ANT68Antenna1.8V DTE1.8V SPI MasterUSB 2.0 Host1.8V Digital Audio DeviceI2S_RXDI2S_CLKI2S_TXDI2S_CLKI2S_TXDI2S_WAI2S_RXDI2S_WA44434241LISA-U120/U130 only20GPIO13V8Network Indicator22RESET_NFerrite Bead47pFApplication ProcessorOpen Drain Output19PWR_ON100kOpen Drain Output00TPTP LISA-U1/LISA-H1 series - System Integration Manual IMPORTANT: Manufacturers of portable applications incorporating the LISA-U1/LISA-H1 series modules are required to have their final product certified and apply for their own FCC Grant and Industry Canada Certificate related to the specific portable device. This is mandatory to meet the SAR requirements for portable devices. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 3G.G2-HW-10002-2 Advance Information System description Page 81 of 116 LISA-U1/LISA-H1 series - System Integration Manual 2 Design-In 2.1 Design-in checklist This section provides a design-in checklist. 2.1.1 Schematic checklist The following are the most important points for a simple schematic check:
DC supply must provide a nominal voltage at VCC pin above the minimum operating range limit. DC supply must be capable of providing 2.5 A current pulses, providing a voltage at VCC pin above the minimum operating range limit and with a maximum 400 mV voltage drop from the nominal value. VCC supply should be clean, with very low ripple/noise: suggested passive filtering parts can be inserted. VCC voltage must ramp from 2.5 V to 3.2 V within 1 ms to allow a proper switch-on of the module. Connect only one DC supply to VCC: different DC supply systems are mutually exclusive. Do not leave PWR_ON floating: add a pull-up resistor to V_BCKP. Dont apply loads which might exceed the limit for maximum available current from V_INT supply. Check that voltage level of any connected pin does not exceed the relative operating range. Capacitance and series resistance must be limited on each SIM signal to match the SIM specifications. Insert the suggested low capacitance ESD protection and passive filtering parts on each SIM signal. Check UART signals direction, since the signal names follow the ITU-T V.24 Recommendation [3]. Provide appropriate access to USB interface and/or to UART RxD, TxD lines and access to PWR_ON and/or RESET_N lines on the application board in order to flash/upgrade the module firmware. Provide appropriate access to USB interface and/or to UART RxD, TxD, CTS, RTS lines for debugging. Add a proper pull-up resistor to a proper supply on each DDC (I2C) interface line, if the interface is used. Capacitance and series resistance must be limited on each line of the DDC interface. Use transistors with at least an integrated resistor in the base pin or otherwise put a 10 k resistor on the board in series to the GPIO when those are used to drive LEDs. Connect the pin number 5 (RSVD) to ground. Insert the suggested passive filtering parts on each used analog audio line. Check the digital audio interface specifications to connect a proper device. Provide proper precautions for ESD immunity as required on the application board. All unused pins can be left floating on the application board except the PWR_ON pin (must be connected to V_BCKP by a pull-up resistor) and the RSVD pin number 5 (must be connected to GND). 2.1.2 Layout checklist The following are the most important points for a simple layout check:
Check 50 nominal characteristic impedance of the RF transmission line connected to ANT pad. Follow the recommendations of the antenna producer for correct antenna installation and deployment
(PCB layout and matching circuitry). Ensure no coupling occurs with other noisy or sensitive signals (primarily MIC signals, audio output signals, SIM signals). VCC line should be wide and short. Route VCC supply line away from sensitive analog signals. 3G.G2-HW-10002-2 Advance Information Design-In Page 82 of 116 LISA-U1/LISA-H1 series - System Integration Manual The high-power audio outputs lines on the application board must be wide enough to minimize series resistance. Ensure proper grounding. Consider No-routing areas for the Data Module footprint. Optimize placement for minimum length of RF line and closer path from DC source for VCC. Design USB_D+ / USB_D- connection as 90 differential pair. Keep routing short and minimize parasitic capacitance on the SPI lines to preserve signal integrity. 2.1.3 Antenna checklist Antenna should have 50 impedance, V.S.W.R less then 3:1, recommended 2:1 on operating bands in deployment geographical area. Follow the recommendations of the antenna producer for correct antenna installation and deployment
(PCB layout and matching circuitry). Antenna should have built in DC resistor to ground to get proper Antenna detection functionality. 3G.G2-HW-10002-2 Advance Information Design-In Page 83 of 116 LISA-U1/LISA-H1 series - System Integration Manual 2.2 Design Guidelines for Layout The following design guidelines must be met for optimal integration of LISA-U1/LISA-H1 series modules on the final application board. 2.2.1 Layout guidelines per pin function This section groups LISA-U1/LISA-H1 series modules pins by signal function and provides a ranking of importance in layout design. Figure 46: Module pin-out with ranked importance for layout design (LISA top view) 3G.G2-HW-10002-2 Advance Information Design-In Page 84 of 116 Very ImportantCareful LayoutCommon PracticeLegend:V_BCKPGNDV_INTRSVDGNDGNDGNDDSRRIDCDDTRGNDRTSCTSTXDRXDGNDVUSB_DETPWR_ONGPIO1GPIO2RESET_NGPIO3GPIO4GNDUSB_D-USB_D+234567891011121131415161718192021222324252627GNDVCCVCCVCCGNDSPI_MRDYSPI_SRDYSPI_MISOSPI_MOSISPI_SCLKSPK_NGNDSPK_PRSVDGPIO5VSIMSIM_RSTSIM_IOSIM_CLKSDASCLI2S_RXDI2S_CLKI2S_TXDI2S_WAMIC_PMIC_N6463626160595857565554655352515049484746454443424140392930313233343536373828GNDGNDGNDGNDGNDGNDGNDGNDGNDGNDGND7574737271706968676676GNDRSVDGNDGNDGNDGNDGNDANTGNDGNDGND LISA-U1/LISA-H1 series - System Integration Manual Rank Function 1st RF Antenna In/out 2nd Main DC Supply Pin(s) ANT VCC Layout Remarks Very Important Very Important Design for 50 characteristic impedance. See section 2.2.1.1 VCC line should be wide and short. Route away from sensitive analog signals. See section 2.2.1.2 Route USB_D+ and USB_D- as differential lines:
design for 90 differential impedance. See section 2.2.1.3 Avoid coupling with noisy signals. See section 2.2.1.4 3rd USB Signals USB_D+
USB_D-
Very Important 4th Analog Audio Careful Layout Audio Inputs Audio Outputs 5th Ground MIC_P, MIC_N SPK_P, SPK_N GND Careful Layout Provide proper grounding. See section 2.2.1.5 6th Sensitive Pin :
Careful Layout Backup Voltage Power On V_BCKP PWR_ON 7th High-speed digital pins:
Careful Layout Avoid coupling with noisy signals. See section 2.2.1.6 Avoid coupling with sensitive signals. See section 2.2.1.7 Common Practice Follow common practice rules for digital pin routing. See section 2.2.1.8 SPI Signals 8th Digital pins and supplies:
SIM Card Interface Digital Audio
(If implemented) DDC UART SPI_SCLK, SPI_MISO, SPI_MOSI, SPI_SRDY, SPI_MRDY VSIM, SIM_CLK, SIM_IO, SIM_RST I2S_CLK, I2S_RXD, I2S_TXD, I2S_WA SCL, SDA TXD, RXD, CTS, RTS, DSR, RI, DCD, DTR External Reset RESET_N General Purpose I/O GPIO1, GPIO2, GPIO3, GPIO4, GPIO5 USB detection VUSB_DET Supply for Interfaces V_INT Table 34: Pin list in order of decreasing importance for layout design 2.2.1.1 RF antenna connection The RF antenna connection pin ANT is very critical in layout design. The PCB line must be designed to provide 50 nominal characteristic impedance and minimum loss up to radiating element. Provide proper transition between the ANT pad to application board PCB Increase GND keep-out (i.e. clearance) for ANT pad to at least 250 m up to adjacent pads metal definition and up to 500 m on the area below the Data Module, as described in Figure 47. Add GND keep-out (i.e. clearance) on buried metal layers below ANT pad and below any other pad of component present on the RF line, if top-layer to buried layer dielectric thickness is below 200 m, to reduce parasitic capacitance to ground (see Figure 47 for the description keep-out area below ANT pad) The transmission line up to antenna connector or pad may be a micro strip or a stripline. In any case must be designed to achieve 50 characteristic impedance Microstrip lines are usually easier to implement and the reduced number of layer transitions up to antenna connector simplifies the design and diminishes reflection losses. However, the electromagnetic field extends to the free air interface above the stripline and may interact with other circuitry 3G.G2-HW-10002-2 Advance Information Design-In Page 85 of 116 LISA-U1/LISA-H1 series - System Integration Manual Buried striplines exhibit better shielding to external and internally generated interferences. They are therefore preferred for sensitive application. In case a stripline is implemented, carefully check that the via pad-stack does not couple with other signals on the crossed and adjacent layers Minimize the transmission line length; the insertion loss should be minimized as much as possible, in the order of a few tenths of a dB The transmission line should not have abrupt change to thickness and spacing to GND, but must be uniform and routed as smoothly as possible The transmission line must be routed in a section of the PCB where minimal interference from noise sources can be expected Route RF transmission line far from other sensitive circuits as it is a source of electromagnetic interference Avoid coupling with VCC routing and analog audio lines Ensure solid metal connection of the adjacent metal layer on the PCB stack-up to main ground layer Add GND vias around transmission line Ensure no other signals are routed parallel to transmission line, or that other signals cross on adjacent metal layer If the distance between the transmission line and the adjacent GND area (on the same layer) does not exceed 5 times the track width of the micro strip, use the Coplanar Waveguide model for 50 characteristic impedance calculation Dont route microstrip line below discrete component or other mechanics placed on top layer When terminating transmission line on antenna connector (or antenna pad) it is very important to strictly follow the connector manufacturers recommended layout GND layer under RF connectors and close to buried vias should be cut out in order to remove stray capacitance and thus keep the RF line 50 . In most cases the large active pad of the integrated antenna or antenna connector needs to have a GND keep-out (i.e. clearance) at least on first inner layer to reduce parasitic capacitance to ground. Note that the layout recommendation is not always available from connector manufacturer: e.g. the classical SMA Pin-Through-Hole needs to have GND cleared on all the layers around the central pin up to annular pads of the four GND posts. Check 50 impedance of ANT line Ensure no coupling occurs with other noisy or sensitive signals Figure 47: GND keep-out area on the top layer around the ANT pad and on the buried metal layer below the ANT pad Any RF transmission line on PCB should be designed for 50 characteristic impedance. Ensure no coupling occurs with other noisy or sensitive signals. 3G.G2-HW-10002-2 Advance Information Design-In Page 86 of 116 Min. 500 umMin. 250 umTop layerBuried metal layerGND planeMicrostrip50 ohm LISA-U1/LISA-H1 series - System Integration Manual Additional guidelines for products marked with the FCC logo - United States only LISA-U1/LISA-H1 series modules can only be used with a host antenna circuit trace layout according to below guidelines and a host system designer must follow the guidelines to keep the original Grant of LISA-U1/LISA-H1 series modules. Strict compliance to the layout reference design already approved (described in the following guidelines) is required to ensure that only approved antenna shall be used in the host system. If in a host system there is any difference from the trace layout already approved, it requires a Class II permissive change or a new grant as appropriate as FCC defines. Compliance of this device in all final host configurations is the responsibility of the Grantee. The approved reference design for LISA-U1/LISA-H1 series modules has a structure of four layers described in the following. The Layer 1 (top layer, see Figure 48) provides a micro strip line to connect the ANT pin of the LISA-U1/LISA-H1 series module to the antenna connector. The ANT pin of the LISA-U1/LISA-H1 series module has to be soldered on the designed pad which is connected to the antenna connector by a micro strip. The characteristics of the micro strip line (coplanar wave guide) are the following:
Thickness = 0.035 mm Width = 0.26 mm Length = 7.85 mm Gap (signal to GND) = 0.5 mm The micro strip line must be designed to achieve 50 characteristic impedance: the dimensions of the micro strip line have to be calculated in a host system according to PCB characteristics provided by PCB manufacturer. Figure 48: Layer 1 (top layer) of u-blox approved interface board for LISA-U1/LISA-H1 series modules The thickness of the dielectric (FR4 Prepreg 1080) from Layer 1 (top layer) to Layer 2 (inner layer) is 0.27 mm. The Layer 2 (inner layer, described in Figure 49) provides a GND plane. Layer 2 thickness is 0.035 mm. 3G.G2-HW-10002-2 Advance Information Design-In Page 87 of 116 Pad designed for the ANT pinAntenna connectorMicrostrip line LISA-U1/LISA-H1 series - System Integration Manual Figure 49: Layer 2 (inner layer) of u-blox approved interface board for LISA-U1/LISA-H1 series modules The thickness of the dielectric (FR4 Laminate 7628) from Layer 2 (inner layer) to Layer 3 (inner layer) is 0.76 mm. The Layer 3 (inner layer, described in Figure 50) is designed for signals routing and GND plane. Layer 3 thickness is 0.035 mm. Figure 50: Layer 3 (inner layer) of u-blox approved interface board for LISA-U1/LISA-H1 series modules The thickness of the dielectric (FR4 Prepreg 1080) from Layer 3 (inner layer) to Layer 4 (bottom layer) is 0.27 mm. The Layer 4 (bottom layer, described in Figure 51) is designed for signals routing, components placement and GND plane. Layer 4 thickness is 0.035 mm. 3G.G2-HW-10002-2 Advance Information Design-In Page 88 of 116 LISA-U1/LISA-H1 series - System Integration Manual Figure 51: Layer 4 (bottom layer) of u-blox approved interface board for LISA-U1/LISA-H1 series modules The antenna must not exceed 3dBi gain to preserve the original u-blox FCC ID. The antenna must be installed and operated with a minimum distance of 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Under the requirements of FCC Section 15.212(a)-iv, the module must contain a permanently attached antenna, or contain a unique antenna connector, and be marketed and operated only with specific antenna(s). In accordance with FCC Section 15.203, the antenna should use a unique coupling connector to the approved reference design for LISA-U1/LISA-H1 series modules, in order to ensure that the design will not be deployed with antenna of different characteristic from the approved type. The use of standard SMA type connector is not permitted, as its standard usage allows easy replacement of the attached antenna. However RP-SMA (Reverse-Polarized-SMA) connector type fulfills the minimum requirements to prevent exchangeability of antenna on the reference design. 2.2.1.2 Main DC supply connection The DC supply of LISA-U1/LISA-H1 series modules is very important for the overall performance and functionality of the integrated product. For detailed description, check the design guidelines in section 1.5.2. Some main characteristics are:
VCC pins are internally connected, but it is recommended to use all the available pins in order to minimize the power loss due to series resistance VCC connection may carry a maximum burst current in the order of 2.5 A. Therefore, it is typically implemented as a wide PCB line with short routing from DC supply (DC-DC regulator, battery pack, etc) The module automatically initiates an emergency shutdown if supply voltage drops below hardware threshold. In addition, reduced supply voltage can set a worst case operation point for RF circuitry that may behave incorrectly. It follows that each voltage drop in the DC supply track will restrict the operating margin at the main DC source output. Therefore, the PCB connection must exhibit a minimum or zero voltage drop. Avoid any series component with Equivalent Series Resistance (ESR) greater than a few milliohms Given the large burst current, VCC line is a source of disturbance for other signals. Therefore route VCC through a PCB area separated from sensitive analog signals. Typically it is good practice to interpose at least one layer of PCB ground between VCC track and other signal routing The VCC supply current supply flows back to main DC source through GND as ground current: provide adequate return path with suitable uninterrupted ground plane to main DC source 3G.G2-HW-10002-2 Advance Information Design-In Page 89 of 116 LISA-U1/LISA-H1 series - System Integration Manual A tank capacitor with low ESR is often used to smooth current spikes. This is most effective when placed as close as possible to VCC. From main DC source, first connect the capacitor and then VCC. If the main DC source is a switching DC-DC converter, place the large capacitor close to the DC-DC output and minimize the VCC track length. Otherwise consider using separate capacitors for DC-DC converter and LISA-U1/LISA-
H1 series module tank capacitor. Note that the capacitor voltage rating may be adequate to withstand the charger over-voltage if battery-pack is used VCC is directly connected to the RF power amplifiers. Add capacitor in the pF range from VCC to GND along the supply path Since VCC is directly connected to RF Power Amplifiers, voltage ripple at high frequency may result in unwanted spurious modulation of transmitter RF signal. This is more likely to happen with switching DC-DC converters, in which case it is better to select the highest operating frequency for the switcher and add a large L-C filter before connecting to the LISA-U1/LISA-H1 series modules in the worst case The large current generates a magnetic field that is not well isolated by PCB ground layers and which may interact with other analog modules (e.g. VCO) even if placed on opposite side of PCB. In this case route VCC away from other sensitive functional units The typical GSM burst has a periodic nature of approx. 217 Hz, which lies in the audible audio range. Avoid coupling between VCC and audio lines (especially microphone inputs) If VCC is protected by transient voltage suppressor / reverse polarity protection diode to ensure that the voltage maximum ratings are not exceeded, place the protecting device along the path from the DC source toward the LISA-U1/LISA-H1 series module, preferably closer to the DC source (otherwise functionality may be compromised) VCC line should be wide and short. Route away from sensitive analog signals. 2.2.1.3 USB signal The LISA-U1/LISA-H1 series modules include a high-speed USB 2.0 compliant interface with a maximum throughput of 480 Mb/s (see Section 1.9.3). Signals USB_D+ / USB_D- carry the USB serial data and signaling. The lines are used in single ended mode for relatively low speed signaling handshake, as well as in differential mode for fast signaling and data transfer. Characteristic impedance of USB_D+ / USB_D- lines is specified by USB standard. The most important parameter is the differential characteristic impedance applicable for odd-
mode electromagnetic field, which should be as close as possible to 90 differential: signal integrity may be degraded if PCB layout is not optimal, especially when the USB signaling lines are very long. Route USB_D+ / USB_D- lines as a differential pair Ensure the differential characteristic impedance is as close as possible to 90 Consider design rules for USB_D+ / USB_D- similar to RF transmission lines, being them coupled differential micro-strip or buried stripline: avoid any stubs, abrupt change of layout, and route on clear PCB area 2.2.1.4 Analog audio (LISA-U120 / LISA-U130 only) Accurate analog audio design is very important to obtain clear and high quality audio. The GSM signal burst has a repetition rate of 217 Hz that lies in the audible range. A careful layout is required to reduce the risk of noise from audio lines due to both VCC burst noise coupling and RF detection. Analog audio is separated in the two paths, 1. Audio Input (uplink path): MIC_P / MIC_N 2. Audio Outputs (downlink path): SPK_P / SPK_N The most sensitive is the uplink path, since the analog input signals are in the microVolts range. 3G.G2-HW-10002-2 Advance Information Design-In Page 90 of 116 LISA-U1/LISA-H1 series - System Integration Manual Avoid coupling of any noisy signals to microphone input lines It is strongly recommended to route MIC signals away from battery and RF antenna lines. Try to skip fast switching digital lines as well Keep ground separation from other noisy signals. Use an intermediate GND layer or vias wall for coplanar signals MIC_P and MIC_N are sensed differentially within the module. Therefore they should be routed as a differential pair up to the audio signal source Cross other signals lines on adjacent layers with 90 crossing Place bypass capacitor for RF very close to active microphone. The preferred microphone should be designed for GSM applications which typically have internal built-in bypass capacitor for RF very close to active device. If the integrated FET detects the RF burst, the resulting DC level will be in the pass-band of the audio circuitry and cannot be filtered by any other device The bias for an external electret active microphone is not provided by the module. Verify that microphone is properly biased from an external low noise supply and verify that the supply noise is properly filtered Output audio lines have two separated configurations. SPK_P / SPK_N are high level balanced output. They are DC coupled and must be used with a speaker connected in bridge configuration Route SPK_P / SPK_N as differential pair, to reduce differential noise pick-up. The balanced configuration will help reject the common mode noise Consider enlarging PCB lines, to reduce series resistive losses, when the audio output is directly connected to low impedance speaker transducer Use twisted pair cables for balanced audio usage If DC decoupling is required, a large capacitor needs to be used, typically in the microFarad range, depending on the load impedance, in order to not increase the lower cut-off frequency of its High-Pass RC filter response 2.2.1.5 Module grounding Good connection of the module with application board solid ground layer is required for correct RF performance. It significantly reduces EMC issues and provides a thermal heat sink for the module. Connect each GND pin with application board solid GND layer. It is strongly recommended that each GND pad surrounding VCC pins have one or more dedicated via down to the application board solid ground layer The shielding metal tabs are connected to GND, and are a fundamental part of electrical grounding and thermal heat-sink. Connect them to board solid ground layer, by soldering them on the baseboard using PCB plated through holes connected to GND net If the application board is a multilayer PCB, then it is required to connect together each GND area with complete via stack down to main board ground layer It is recommended to implement one layer of the application board as ground plane Good grounding of GND pads will also ensure thermal heat sink. This is critical during call connection, when the real network commands the module to transmit at maximum power: proper grounding helps prevent module overheating 2.2.1.6 Other sensitive pins A few other pins on the LISA-U1/LISA-H1 series modules requires careful layout. RTC supply (V_BCKP): avoid injecting noise on this voltage domain as it may affect the stability of sleep oscillator 3G.G2-HW-10002-2 Advance Information Design-In Page 91 of 116 LISA-U1/LISA-H1 series - System Integration Manual Power On (PWR_ON): is the digital input to switch-on the LISA-U1/LISA-H1 series modules. Ensure that the voltage level is well defined during operation and no transient noise is coupled on this line, otherwise the module might detect a spurious power on request 2.2.1.7 High-speed digital pins The Serial Peripheral Interface Bus (SPI) interface can be used for high speed data transfer (UMTS/HSPA) between the LISA-U1/LISA-H1 series modules and the host processor, with a data rate up to 20 Mb/s (see Section 1.9.3). The high-speed data rate is carried by signals SPI_SCLK, SPI_MISO and SPI_MOSI, while SPI_SRDY and SPI_MRDY behave as handshake signals with relatively low activity. High-speed signals become sources of digital noise, route away from RF and other sensitive analog signals Keep routing short and minimize parasitic capacitance to preserve digital signal integrity 2.2.1.8 Digital pins and supplies External Reset (RESET_N): input for external reset, a logic low voltage will reset the module SIM Card Interface (VSIM, SIM_CLK, SIM_IO, SIM_RST): the SIM layout may be critical if the SIM card is placed far away from the LISA-U1/LISA-H1 series modules or in close proximity to the RF antenna. In the first case the long connection can cause the radiation of some harmonics of the digital data frequency. In the second case the same harmonics can be picked up and create self-interference that can reduce the sensitivity of GSM Receiver channels whose carrier frequency is coincidental with harmonic frequencies. The latter case, placing the RF bypass capacitors, suggested in Figure 20, near the SIM connector will mitigate the problem. In addition, since the SIM card is typically accessed by the end user, it can be subjected to ESD discharges: add adequate ESD protection to protect module SIM pins near the SIM connector. Digital Audio (I2S_CLK, I2S_RX, I2S_TX, I2S_WA): the I2S interface requires the same consideration regarding electro-magnetic interference as the SIM card. Keep the traces short and avoid coupling with RF line or sensitive analog inputs DDC (SCL, SDA): the DDC interface requires the same consideration regarding electro-magnetic interference as the SIM card. Keep the traces short and avoid coupling with RF line or sensitive analog inputs UART (TXD, RXD, CTS, RTS, DSR, RI, DCD, DTR): the serial interface requires the same consideration regarding electro-magnetic interference as the SIM card. Keep the traces short and avoid coupling with RF line or sensitive analog inputs General Purpose I/O (GPIOx): the general purpose input/output pins are generally not critical for layout Reserved pins: these pins are reserved for future use. Leave them unconnected on the baseboard USB detection (VUSB_DET): this input will generate an interrupt to the baseband processor for USB detection. The USB supply (5.0 V typ.) must be provided to VUSB_DET by the connected USB host to enable the USB interface of the module Interfaces Supply (V_INT): this supply output is generated by an integrated switching step down converter, used internally to supply the digital interfaces. Because of this, it can be a source of noise: avoid coupling with sensitive signals 3G.G2-HW-10002-2 Advance Information Design-In Page 92 of 116 LISA-U1/LISA-H1 series - System Integration Manual 2.2.2 Footprint and paste mask The following figure describes the footprint and provides recommendations for the paste mask for LISA-U1/LISA-
H1 series modules. These are recommendations only and not specifications. Note that the copper and solder masks have the same size and position. Figure 52: LISA-U1/LISA-H1 series modules suggested footprint and paste mask To improve the wetting of the half vias, reduce the amount of solder paste under the module and increase the volume outside of the module by defining the dimensions of the paste mask to form a T-shape (or equivalent) extending beyond the copper mask. The solder paste should have a total thickness of 120 m. The paste mask outline needs to be considered when defining the minimal distance to the next component. The exact geometry, distances, stencil thicknesses and solder paste volumes must be adapted to the specific production processes (e.g. soldering etc.) of the customer. The bottom layer of LISA-U1/LISA-H1 series modules shows an unprotected copper area for GND described in Figure 53. Consider No-routing area for the LISA-U1/LISA-H1 series modules footprint as follows: signals keep-
out area on the top layer of the application board, below LISA-U1/LISA-H1 series modules, due to GND opening on module bottom layer (see Figure 53). 3G.G2-HW-10002-2 Advance Information Design-In Page 93 of 116 33.2 mm [1307.1 mil] 22.4 mm [881.9 mil]2.3 mm [90.6 mil]0.8 mm [31.5 mil]1.1 mm [43.3 mil]0.8 mm [31.5 mil]1.0 mm [39.3 mil]5.7 mm [224.4 mil]33.2 mm [1307.1 mil] 22.4 mm [881.9 mil]2.3 mm [90.6 mil]1.2 mm [47.2 mil]1.1 mm [43.3 mil]0.8 mm [31.5 mil]0.9 mm [35.4 mil]5.7 mm [224.4 mil]0.6 mm [23.6 mil]Stencil: 120 m LISA-U1/LISA-H1 series - System Integration Manual Figure 53: Signals keep-out area on the top layer of the application board, below LISA-U1/LISA-H1 series modules 2.2.3 Placement Optimize placement for minimum length of RF line and closer path from DC source for VCC. The heat dissipation during continuous transmission at maximum power can significantly raise the temperature of the application base-board below the LISA-U1/LISA-H1 series modules: avoid placing temperature sensitive devices (e.g. GPS receiver) close to the module. 3G.G2-HW-10002-2 Advance Information Design-In Page 94 of 116 5.3 mm11.85 mm33.2 mm 1.0 mm1.4 mmPIN 1Bottom side (through module view)22.40 mmExposed GND on LISA module bottom layerSignals keep-out area on application board LISA-U1/LISA-H1 series - System Integration Manual 2.3 Thermal aspects The operating temperature range is specified in the LISA-U1/LISA-H1 series Data Sheet [1]. The most critical condition concerning thermal performance is the uplink transmission at maximum power (data upload or voice call in connected mode), when the baseband processor runs at full speed, radio circuits are all active and the RF power amplifier is driven to higher output RF power. This scenario is not often encountered in real networks; however the application should be correctly designed to cope with it. During transmission at maximum RF power the LISA-U1/LISA-H1 series modules generate thermal power that can exceed 2 W: this is an indicative level since the exact generated power strictly depends on operating condition such as the number of allocated TX slot and modulation (GMSK or 8PSK) or data rate (WCDMA), transmitting frequency band, etc. The generated thermal power must be adequately dissipated through the thermal and mechanical design of the application. The increase of thermal dissipation, i.e. reducing the thermal resistance, will reduce the operating temperature for internal circuitry of LISA-U1/LISA-H1 series modules for the same operating ambient temperature. This improves the device long-term reliability for applications operating at high ambient temperature. A few techniques may be used to reduce the thermal resistance in the application:
Forced ventilation air-flow within mechanical enclosure Usage of thermal transfer material (e.g. greases and pastes) Heat sink attached to the module top side, with electrically insulated / high thermal conductivity adhesive Connect each GND pin with solid ground layer of the application board and connect each ground area of the multilayer application board with complete via stack down to main ground layer 3G.G2-HW-10002-2 Advance Information Design-In Page 95 of 116 LISA-U1/LISA-H1 series - System Integration Manual 2.4 Antenna guidelines Antenna characteristics are essential for good functionality of the module. Antenna radiating performance has direct impact on the reliability of connections over the Air Interface. A bad termination of ANT can result in poor performance of the module. The following parameters should be checked:
Item Impedance Frequency Range Recommendations 50 nominal characteristic impedance Depends on the LISA-U1/LISA-H1 series module version and on the Mobile Network used. LISA-U100/U120/H100:
- GSM 850: 824..894 MHz = UMTS B5: 824..894 MHz
- GSM 1900: 1850..1990 MHz = UMTS B2: 1850..1990 MHz LISA-U110/U130/H110:
- GSM 900: 880..960 MHz = UMTS B8: 880..960 MHz
- GSM 1800: 1710..1880 MHz
- UMTS B1: 1920..2170 MHz Input Power V.S.W.R Return Loss Gain
>2 W peak
<2:1 recommended, <3:1 acceptable S11<-10 dB recommended, S11<-6 dB acceptable
<3 dBi Table 35: General recommendation for GSM antenna To preserve the original u-blox FCC ID antenna gain shall remain below 3 dBi. Please note that some 2G and 3G bands are overlapping. This depends on worldwide band allocation for telephony services, where different bands are deployed for different geographical regions. If the LISA-U110/U130 modules are planned for use on the entire supported bands, then a tri-band antenna
(880..960 MHz, 1710..1880 MHz, 1920..2170 MHz) should be selected. If the LISA-U100/U120 modules are planned for use on the entire supported bands, then a dual-band antenna (824..894 MHz, 1850..1990 MHz) should be selected. Otherwise, for fixed applications in specific geographical region, antenna requirements can be relaxed for non-deployed frequency bands. GSM antennas are typically available as:
Linear monopole: typical for fixed applications. The antenna extends mostly as a linear element with a dimension comparable to lambda/4 of the lowest frequency of the operating band. Magnetic base may be available. Cable or direct RF connectors are common options. The integration normally requires the fulfillment of some minimum guidelines suggested by antenna manufacturer Patch-like antenna: better suited for integration in compact designs (e.g. mobile phone). These are mostly custom designs where the exact definition of the PCB and product mechanical design is fundamental for tuning of antenna characteristics For integration observe these recommendations:
Ensure 50 antenna termination, minimize the V.S.W.R. or return loss, as this will optimize the electrical performance of the module. See section 2.4.1 Select antenna with best radiating performance. See section 2.4.2 If a cable is used to connect the antenna radiating element to application board, select a short cable with minimum insertion loss. The higher the additional insertion loss due to low quality or long cable, the lower the connectivity Follow the recommendations of the antenna manufacturer for correct installation and deployment Do not include antenna within closed metal case 3G.G2-HW-10002-2 Advance Information Design-In Page 96 of 116 LISA-U1/LISA-H1 series - System Integration Manual Do not place antenna in close vicinity to end user since the emitted radiation in human tissue is limited by S.A.R. regulatory requirements Do not use directivity antenna since the electromagnetic field radiation intensity is limited in some countries Take care of interaction between co-located RF systems since the GSM transmitted power may interact or disturb the performance of companion systems Place antenna far from sensitive analog systems or employ countermeasures to reduce electromagnetic compatibility issues that may arise 2.4.1 Antenna termination The LISA-U1/LISA-H1 series modules are designed to work on a 50 load. However, real antennas have no perfect 50 load on all the supported frequency bands. Therefore, in order to as much as possible reduce performance degradation due to antenna mismatch, the following requirements should be met:
Measure the antenna termination with a network analyzer: connect the antenna through a coaxial cable to the measurement device, the |S11| indicates which portion of the power is delivered to antenna and which portion is reflected by the antenna back to the module output. A good antenna should have an |S11| below -10 dB over the entire frequency band. Due to miniaturization, mechanical constraints and other design issues, this value will not be achieved. An |S11| value of about -6 dB - (in the worst case) - is acceptable. Figure 54 shows an example of this measurement:
Figure 54: |S11| sample measurement of a penta-band antenna that covers in a small form factor the 4 GSM bands (850 MHz, 900 MHz, 1800 MHz and 1900 MHz) and the UMTS Band I Figure 55 shows comparable measurements performed on a wideband antenna. The termination is better, but the size of the antenna is considerably larger. 3G.G2-HW-10002-2 Advance Information Design-In Page 97 of 116 LISA-U1/LISA-H1 series - System Integration Manual Figure 55: |S11| sample measurement of a wideband antenna 2.4.2 Antenna radiation An indication of the antennas radiated power can be approximated by measuring the |S21| from a target antenna to the measurement antenna, using a network analyzer with a wideband antenna. Measurements should be done at a fixed distance and orientation, and results compared to measurements performed on a known good antenna. Figure 56 through Figure 57 show measurement results. A wideband log periodic-like antenna was used, and the comparison was done with a half lambda dipole tuned at 900 MHz frequency. The measurements show both the |S11| and |S21| for the penta-band internal antenna and for the wideband antenna. Figure 56: |S11| and |S21| comparison between a 900 MHz tuned half wavelength dipole (green/purple) and a penta-band internal antenna (yellow/cyan) The half lambda dipole tuned at 900 MHz is known and has good radiation performance (both for gain and directivity). Then, by comparing the |S21| measurement with antenna under investigation for the frequency where the half dipole is tuned (e.g. marker 3 in Figure 56) it is possible to make a judgment on the antenna under test:
if the performance is similar then the target antenna is good. 3G.G2-HW-10002-2 Advance Information Design-In Page 98 of 116 LISA-U1/LISA-H1 series - System Integration Manual Figure 57: |S11| and |S21| comparison between a 900 MHz tuned half wavelength dipole (green/purple) and a wideband commercial antenna (yellow/cyan) Instead if |S21| values for the tuned dipole are much better than the antenna under evaluation (like for marker 1/2 area of Figure 57, where dipole is 5 dB better), then it can be argued that the radiation of the target antenna
(the wideband dipole in this case) is considerably less. The same procedure should be repeated on other bands with half wavelength dipole re-tuned to the band under investigation. For good antenna radiation performance, antenna dimensions should be comparable to a quarter of the wavelength. Different antenna types can be used for the module, many of them (e.g. patch antennas, monopole) are based on a resonating element that works in combination with a ground plane. The ground plane, ideally infinite, can be reduced down to a minimum size that must be similar to one quarter of the wavelength of the minimum frequency that has to be radiated (transmitted/received). Numerical sample: frequency = 1 GHz wavelength = 30 cm minimum ground plane (or antenna size) = 7.5 cm. Below this size, the antenna efficiency is reduced. 2.4.3 Antenna detection functionality The internal antenna detect circuit is based on ADC measurement at ANT: the RF port is DC coupled to the ADC unit in the baseband chip which injects a DC current (10 A for 128 s) on ANT and measures the resulting DC voltage to evaluate the resistance from ANT pad to GND. The antenna detection is forced by the +UANTR AT command: refer to the u-blox AT Commands Manual [2] for more details on how to access this feature. To achieve antenna detection functionality, use an RF antenna with built-in resistor from ANT signal to GND, or implement an equivalent solution with a circuit between the antenna cable connection and the radiating element as shown in Figure 58. 3G.G2-HW-10002-2 Advance Information Design-In Page 99 of 116 LISA-U1/LISA-H1 series - System Integration Manual Figure 58: Antenna detection circuit and antenna with diagnostic resistor Examples of components for the antenna detection diagnostic circuit are reported in the following table:
Description Part Number - Manufacturer DC Blocking Capacitor Murata GRM1555C1H220JA01 or equivalent RF Choke Inductor Resistor for Diagnostic Murata LQG15HS68NJ02, LQG15HH68NJ02 or equivalent (Self Resonance Frequency ~1GHz) 15 k 5%, various Manufacturers Table 36: Example of components for the antenna detection diagnostic circuit Please note that the DC impedance at RF port for some antennas may be a DC open (e.g. linear monopole) or a DC short to reference GND (e.g. PIFA antenna). For those antennas, without the diagnostic circuit of Figure 58, the measured DC resistance will always be at the limits of the measurement range (respectively open or short), and there will be no mean to distinguish between a defect on antenna path with similar characteristics
(respectively: removal of linear antenna or RF cable shorted to GND for PIFA antenna). Furthermore, any other DC signal injected to the RF connection from ANT connector to radiating element will alter the measurement and produce invalid results for antenna detection. It is recommended to use an antenna with a built-in diagnostic resistor in the range from 5 k to 30 k to assure good antenna detection functionality and to avoid a reduction of module RF performance. The choke inductor should exhibit a parallel Self Resonance Frequency (SRF) in the range of 1 GHz to improve the RF isolation of load resistor. For example:
Consider a GSM antenna with built-in DC load resistor of 15 k. Using the +UANTR AT command, the module reports the resistance value evaluated from ANT connector to GND:
3G.G2-HW-10002-2 Advance Information Design-In Page 100 of 116 Application BoardAntenna AssemblyDiagnostic CircuitLISA-U1/LISA-H1 seriesADCCurrent SourceRF ChokeDC BlockingFront-End RF ModuleRF ChokeDC BlockingRadiating ElementZo=50 Resistor for DiagnosticCoaxial Antenna CableANT LISA-U1/LISA-H1 series - System Integration Manual Reported values close to the used diagnostic resistor nominal value (i.e. values from 13 k to 17 k if a 15 k diagnostic resistor is used) indicate that the antenna is properly connected Values close to the measurement range maximum limit (approximately 50 k) or an open-circuit over range report (see u-blox AT Commands Manual [2]) means that that the antenna is not connected or the RF cable is broken Reported values below the measurement range minimum limit (1 k) will highlight a short to GND at antenna or along the RF cable Measurement inside the valid measurement range and outside the expected range may indicate an improper connection, damaged antenna or wrong value of antenna load resistor for diagnostic Reported value could differ from the real resistance value of the diagnostic resistor mounted inside the antenna assembly due to antenna cable length, antenna cable capacity and the used measurement method 3G.G2-HW-10002-2 Advance Information Design-In Page 101 of 116 LISA-U1/LISA-H1 series - System Integration Manual 2.5 ESD immunity test precautions The immunity to the EMS phenomenon Electrostatic Discharge of the device (i.e. the application board where the LISA-U1/LISA-H1 series module is mounted) must be certified complying the testing requirements standard
[10] and the requirements for radio and digital cellular radio telecommunications system equipments standards
[11] [12]. The ESD test is performed at the enclosure port [11] referred as the physical boundary through which EM field radiates. If the device implements an integral antenna [11] the enclosure is intended as all insulating surfaces housing the device. If the device implements a removable antenna [11] the enclosure port is limited to the antenna port [11] hence the enclosure port comprises the antenna element and its interconnecting cable surfaces. The applicability of the ESD test depends to the device classification [11], as well the test on other ports [11] or on interconnecting cables to auxiliary equipments depends to the device accessible interfaces and manufacturer requirements. Contact discharges [10] are performed at conductive surfaces whereas air discharges [10] are performed at insulating surfaces. Indirect contact discharges are performed on the measurement setup horizontal and vertical coupling planes [10]. Some precautions should be implemented as described in the following sections in order to satisfy ESD immunity test requirements [10] [11] [12] performed at device enclosure complying the category level [11] and shown in the following table. Category Contact Discharge to coupling planes (indirect contact discharge) Contact Discharges to conducted surfaces (direct contact discharge) Air Discharge at insulating surfaces Immunity Level
+2 kV / -2 kV
+4 kV / -4 kV Not Applicable2*
+2 kV / -2 kV
+4 kV / -4 kV
+8 kV / -8 kV Table 37: Enclosure ESD immunity level, standards EN 61000-4-2, EN 301 489-1 V1.8.1, EN 301 489-7 V1.3.1 2.5.1 General precautions The following module interfaces could be involved in the ESD immunity test criticality depending on the application board handling. Some precautions are herein suggested. Sensitive interface is the reset line (RESET_N pin):
A 47 pF bypass capacitor (e.g. Murata GRM1555C1H470JA01) have to be mounted on the line termination connected to the RESET_N pin to avoid a module reset caused by an electrostatic discharge applied to the application board A series ferrite bead (e.g. Murata BLM15HD182SN1) must be added on the line connected to the RESET_N pin to avoid a module reset caused by an electrostatic discharge applied to the application board 2 LISA mounted on application reference design:
Applicability -> EUT with insulating surfaces, air discharges on interconnecting cables between EUT and antenna and auxiliary equipments Not Applicability -> EUT with conductive surface, direct contact discharge 3G.G2-HW-10002-2 Advance Information Design-In Page 102 of 116 LISA-U1/LISA-H1 series - System Integration Manual It is recommended to keep the connection line to RESET_N as short as possible Figure 59: RESET_N application circuits for ESD immunity test Reference Description Remarks ESD C1, C2 FB1, FB2 Rint Varistor for ESD protection. CT0402S14AHSG - EPCOS 47 pF Capacitor Ceramic C0G 0402 5% 50 V GRM1555C1H470JA01 - Murata Chip Ferrite Bead for Noise/EMI Suppression BLM15HD182SN1 - Murata 10 k Resistor 0402 5% 0.1 W Internal pull-up resistor Table 38: Example of components as ESD immunity test precautions for the RESET_N line Sensitive interface is the SIM interface (VSIM pin, SIM_RST pin, SIM_IO pin, SIM_CLK pin):
A 47 pF bypass capacitor (e.g. Murata GRM1555C1H470J) have to be mounted on the lines connected to VSIM, SIM_RST, SIM_IO and SIM_CLK to assure SIM interface functionality when an electrostatic discharge is applied to the application board It is suggested to use as short as possible connection lines at SIM pins 2.5.2 Antenna interface precautions The antenna interface ANT could be involved in the ESD immunity test criticality depending on the application board handling. Antenna precaution is herein suggested. If the device implements an embedded antenna and the device insulating enclosure avoids air discharge up to +8 kV / -8 kV to the antenna interface, no further precautions to ESD immunity test should be needed If the device implements an external antenna and the antenna and its connecting cable are provided with a completely insulating enclosure to avoid air discharge up to +8 kV / -8 kV to the whole antenna and cable surfaces, no further precautions to ESD immunity test should be needed 3G.G2-HW-10002-2 Advance Information Design-In Page 103 of 116 LISA-U1/LISA-H1 series2V_BCKP22RESET_NReset push buttonESDOpen Drain OutputApplication ProcessorLISA-U1/LISA-H1 series2V_BCKP22RESET_NRintRintFB1C1FB2C2 LISA-U1/LISA-H1 series - System Integration Manual If the device implements an external antenna and the antenna or its connecting cable are not provided with completely insulating enclosure to avoid air discharge up to +8 kV / -8 kV to the whole antenna and cable surfaces, precautions to ESD immunity test should be implemented on the application board A higher protection level is required at the ANT port if the line is externally accessible on the application board. 2.5.3 Module interfaces precautions All the module pins that are externally accessible should be included in the ESD immunity test since they are considered to be a port [11]. Depending on applicability, and in order to satisfy ESD immunity test requirements and ESD category level, pins connected to the port should be protected up to +4 kV / -4 kV for direct Contact Discharge, and up to +8 kV / -8 kV for Air Discharge applied to the enclosure. The maximum ESD rating of all the pins of the module, except the ANT pin, is 1 kV (HBM according MIL-Std 883D, method 3015.7, EOS/ESD Standard S5.1-1993). A higher protection level can be achieved by mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor array). 3G.G2-HW-10002-2 Advance Information Design-In Page 104 of 116 LISA-U1/LISA-H1 series - System Integration Manual 3 Handling and soldering No natural rubbers, no hygroscopic materials or materials containing asbestos are employed. 3.1 Packaging, shipping, storage and moisture preconditioning For information pertaining to reels and tapes, Moisture Sensitivity levels (MSD), shipment and storage information, as well as drying for preconditioning see the LISA-U1/LISA-H1 series Data Sheet [1]. The LISA-U1/LISA-H1 series modules are Electro-Static Discharge (ESD) sensitive devices. Ensure ESD precautions are implemented during handling of the module. 3.2 Soldering 3.2.1 Soldering paste Use of "No Clean" soldering paste is strongly recommended, as it does not require cleaning after the soldering process has taken place. The paste listed in the example below meets these criteria. Soldering Paste:
OM338 SAC405 / Nr.143714 (Cookson Electronics) Alloy specification:
95.5% Sn / 3.9% Ag / 0.6% Cu (95.5% Tin / 3.9% Silver / 0.6% Copper) 95.5% Sn / 4.0% Ag / 0.5% Cu (95.5% Tin / 4.0% Silver / 0.5% Copper) Melting Temperature: 217C Stencil Thickness:
120 m for base boards The final choice of the soldering paste depends on the approved manufacturing procedures. The paste-mask geometry for applying soldering paste should meet the recommendations in section 2.2.2 The quality of the solder joints on the connectors (half vias) should meet the appropriate IPC specification. 3.2.2 Reflow soldering A convection type-soldering oven is strongly recommended over the infrared type radiation oven. Convection heated ovens allow precise control of the temperature and all parts will be heated up evenly, regardless of material properties, thickness of components and surface color. Consider the "IPC-7530 Guidelines for temperature profiling for mass soldering (reflow and wave) processes, published 2001". Preheat phase Initial heating of component leads and balls. Residual humidity will be dried out. Please note that this preheat phase will not replace prior baking procedures. Temperature rise rate: max 3C/s Time: 60 120 s If the temperature rise is too rapid in the preheat phase it may cause excessive slumping. If the preheat is insufficient, rather large solder balls tend to be generated. Conversely, if performed excessively, fine balls and large balls will be generated in clusters. 3G.G2-HW-10002-2 Advance Information Handling and soldering Page 105 of 116 LISA-U1/LISA-H1 series - System Integration Manual End Temperature: 150 - 200C If the temperature is too low, non-melting tends to be caused in areas containing large heat capacity. Heating/ reflow phase The temperature rises above the liquidus temperature of 217C. Avoid a sudden rise in temperature as the slump of the paste could become worse. Limit time above 217C liquidus temperature: 40 - 60 s Peak reflow temperature: 245C Cooling phase A controlled cooling avoids negative metallurgical effects (solder becomes more brittle) of the solder and possible mechanical tensions in the products. Controlled cooling helps to achieve bright solder fillets with a good shape and low contact angle. Temperature fall rate: max 4C / s To avoid falling off, modules should be placed on the topside of the motherboard during soldering. The final soldering temperature chosen at the factory depends on additional external factors like choice of soldering paste, size, thickness and properties of the base board, etc. Exceeding the maximum soldering temperature in the recommended soldering profile may permanently damage the module. Figure 60: Recommended soldering profile When soldering lead-free LISA-U1/LISA-H1 series modules in a leaded process, check the following temperatures:
PB- Technology Soaktime: 40-80 s Time above Liquidus:
40-90 s Peak temperature:
225-235C LISA-U1/LISA-H1 series modules must not be soldered with a damp heat process. 3G.G2-HW-10002-2 Advance Information Handling and soldering Page 106 of 116 PreheatHeatingCooling[C]Peak Temp. 245C[C]250250Liquidus Temperature21721720020040 - 60 sEnd Temp.max 4C/s150 - 200C150150max 3C/s60 - 120 s100Typical Leadfree100Soldering Profile5050050100150200250300Elapsed time [s]
LISA-U1/LISA-H1 series - System Integration Manual 3.2.3 Optical inspection After soldering the LISA-U1/LISA-H1 series modules, inspect the modules optically to verify that he module is properly aligned and centered. 3.2.4 Cleaning Cleaning the soldered modules is not recommended. Residues underneath the modules cannot be easily removed with a washing process. Cleaning with water will lead to capillary effects where water is absorbed in the gap between the baseboard and the module. The combination of residues of soldering flux and encapsulated water leads to short circuits or resistor-like interconnections between neighboring pads. Water will also damage the sticker and the ink-
jet printed text. Cleaning with alcohol or other organic solvents can result in soldering flux residues flooding into the two housings, areas that are not accessible for post-wash inspections. The solvent will also damage the sticker and the ink-jet printed text. Ultrasonic cleaning will permanently damage the module, in particular the quartz oscillators. For best results use a "no clean" soldering paste and eliminate the cleaning step after the soldering. 3.2.5 Repeated reflow soldering Only a single reflow soldering process is encouraged for boards with a LISA-U1/LISA-H1 series module populated on it. The reason for this is the risk of the module falling off due to high weight in relation to the adhesive properties of the solder. 3.2.6 Wave soldering Boards with combined through-hole technology (THT) components and surface-mount technology (SMT) devices require wave soldering to solder the THT components. Only a single wave soldering process is encouraged for boards populated with LISA-U1/LISA-H1 series modules. 3.2.7 Hand soldering Hand soldering is not recommended. 3.2.8 Rework The LISA-U1/LISA-H1 series modules can be unsoldered from the baseboard using a hot air gun. After the module is removed, clean the pads before placing. Avoid overheating the module. Never attempt a rework on the module itself, e.g. replacing individual components. Such actions immediately terminate the warranty. 3.2.9 Conformal coating Certain applications employ a conformal coating of the PCB using HumiSeal or other related coating products. These materials affect the HF properties of the LISA-U1/LISA-H1 series modules and it is important to prevent them from flowing into the module. The RF shields do not provide 100% protection for the module from coating liquids with low viscosity, therefore care is required in applying the coating. Conformal Coating of the module will void the warranty. 3G.G2-HW-10002-2 Advance Information Handling and soldering Page 107 of 116 LISA-U1/LISA-H1 series - System Integration Manual 3.2.10 Casting If casting is required, use viscose or another type of silicon pottant. The OEM is strongly advised to qualify such processes in combination with the LISA-U1/LISA-H1 series modules before implementing this in the production. Casting will void the warranty. 3.2.11 Grounding metal covers Attempts to improve grounding by soldering ground cables, wick or other forms of metal strips directly onto the EMI covers is done at the customer's own risk. The numerous ground pins should be sufficient to provide optimum immunity to interferences and noise. u-blox gives no warranty for damages to the LISA-U1/LISA-H1 series modules caused by soldering metal cables or any other forms of metal strips directly onto the EMI covers. 3.2.12 Use of ultrasonic processes Some components on the LISA-U1/LISA-H1 series modules are sensitive to Ultrasonic Waves. Use of any Ultrasonic Processes (cleaning, welding etc.) may cause damage to the module. u-blox gives no warranty against damages to the LISA-U1/LISA-H1 series modules caused by any Ultrasonic Processes. 3G.G2-HW-10002-2 Advance Information Handling and soldering Page 108 of 116 LISA-U1/LISA-H1 series - System Integration Manual 4 Product Testing 4.1 u-blox in-series production test u-blox focuses on high quality for its products. All units produced are fully tested. Defective units are analyzed in detail to improve the production quality. This is achieved with automatic test equipment, which delivers a detailed test report for each unit. The following measurements are done:
Digital self-test (Software Download, verification of FLASH firmware, etc.) Measurement of voltages and currents Measurement of RF characteristics Figure 61: Automatic test equipment for module tests 4.2 Test parameters for OEM manufacturer The chapter will be completed in the next releases. 3G.G2-HW-10002-2 Advance Information Product Testing Page 109 of 116 LISA-U1/LISA-H1 series - System Integration Manual Appendix A Extra Features A.1 TCP/IP Via the AT commands its possible to access the TCP/IP functionalities over the GPRS connection. For more details about AT commands see the u-blox AT Commands Manual [2]. A.1.1 Multiple IP addresses and sockets Using LISAs embedded TCP/IP or UDP/IP stack, only 1 IP instance (address) is supported. The IP instance supports up to 16 sockets. Using an external TCP/IP stack (on the application processor), it is possible to have 2 IP instances (addresses). A.2 FTP LISA-U1/LISA-H1 series modules will support this feature in the upcoming version. A.3 FTPS LISA-U1/LISA-H1 series modules will support this feature in the upcoming version. A.4 HTTP LISA-U1/LISA-H1 series modules will support this feature in the upcoming version. A.5 HTTPS LISA-U1/LISA-H1 series modules will support this feature in the upcoming version. A.6 SMTP LISA-U1/LISA-H1 series modules will support this feature in the upcoming version. A.7 AssistNow clients and GPS integration For customers using u-blox GPS receivers, LISA-U1/LISA-H1 series modules feature embedded AssistNow Online and AssistNow Offline clients. AssistNow A-GPS provides better GPS performance and faster Time-To-First-Fix. The clients can be enabled / disabled with an AT command. LISA-U1/LISA-H1 series modules act as a stand-alone AssistNow client, making AssistNow available with no additional requirements for resources or software integration on an external host micro controller. Full access to u-blox GPS receivers is available via the LISA-U1/LISA-H1 series, through a dedicated DDC (I2C) interface, while the available GPIOs can handle the GPS device power on/off. This means that GSM/EDGE and GPS can be controlled through a single serial port from any host processor. A.8 In-Band modem (LISA-U130 only) LISA-U130 Automotive grade version implements the in-Band modem solution for eCall according to the 3GPP TS 26.267 specification [13]. According to the eCall (Pan-European automatic in-vehicle emergency call system) specification, an eCall must be generated automatically or manually following an car accident using GSM cellular service 112. When activated, the in-vehicle eCall system (IVS) creates an emergency call carrying both voice and data (e.g. vehicle GPS position) directly to the nearest 112 Public Safety Answering Point (PSAP) to quickly decide upon detaching rescue services to the known position. 3G.G2-HW-10002-2 Advance Information Appendix Page 110 of 116 LISA-U1/LISA-H1 series - System Integration Manual Figure 62: In-Band modem diagram flow In-band modem allows the fast and reliable transmission of vehicle Minimum Set of Data (MSD - 140 bytes) and the establishment of a voice emergency call using the same physical channel (voice channel) without any modifications of the existing cellular network architecture. In-Band modem is a mandatory feature to meet the eCall requirements and to develop in vehicle devices fully supporting eCall. The in-Band modem functionality is delivered upon request. A.9 Smart temperature supervision An internal sensor is used to constantly monitor the board temperature of the LISA-U1/LISA-H1 series modules. The measured value is compared with the internally predefined thresholds and it proceeds accordingly. A warning notification is reported by the module when the temperature value is still inside the valid range (i.e. the module is still in a valid and good working condition) but it is close to the limit (upper or lower). A shutdown is notified and automatically forced by the module when the temperature value is outside the specified range (i.e. the module is in a dangerous working condition). For security reasons the shutdown is suspended in case of emergency call in progress: in this case the device will switch off at call termination. The Smart Temperature Supervisor feature can be enabled or disabled through an AT command (for more details please to u-blox AT commands manual [2], +USTS AT command). If the feature is disabled there is no embedded protection against not allowed temperature working conditions. The sensor measures board temperature inside the shields, which can differ from ambient temperature. 3G.G2-HW-10002-2 Advance Information Appendix Page 111 of 116 LISA-U1/LISA-H1 series - System Integration Manual B Glossary ADC AP AT CBCH CS CSD CTS DC DCD DCE DCS DDC DSP DSR DTE DTM DTR EBU EDGE E-GPRS FDD FEM FOAT FTP FTPS GND GPIO GPRS GPS GSM HF HSDPA HTTP HTTPS HW I/Q I2C I2S IP IPC LNA Analog to Digital Converter Application Processor AT Command Interpreter Software Subsystem, or attention Cell Broadcast Channel Coding Scheme Circuit Switched Data Clear To Send Direct Current Data Carrier Detect Data Communication Equipment Digital Cellular System Display Data Channel Digital Signal Processing Data Set Ready Data Terminal Equipment Dual Transfer Mode Data Terminal Ready External Bus Interface Unit Enhanced Data rates for GSM Evolution Enhanced GPRS Frequency Division Duplex Front End Module Firmware Over AT commands File Transfer Protocol FTP Secure Ground General Purpose Input Output General Packet Radio Service Global Positioning System Global System for Mobile Communication Hands-free High Speed Downlink Packet Access HyperText Transfer Protocol Hypertext Transfer Protocol over Secure Socket Layer Hardware In phase and Quadrature Inter-Integrated Circuit Inter IC Sound Internet Protocol Inter Processor Communication Low Noise Amplifier 3G.G2-HW-10002-2 Advance Information Appendix Page 112 of 116 LISA-U1/LISA-H1 series - System Integration Manual MCS NOM PA PBCCH PCM PCS PFM PMU RF RI RTC RTS RXD SAW SIM SMS SMTP SPI SRAM TCP TDMA TXD UART UDP UMTS USB UTRA Modulation Coding Scheme Network Operating Mode Power Amplifier Packet Broadcast Control Channel Pulse Code Modulation Personal Communications Service Pulse Frequency Modulation Power Management Unit Radio Frequency Ring Indicator Real Time Clock Request To Send RX Data Surface Acoustic Wave Subscriber Identification Module Short Message Service Simple Mail Transfer Protocol Serial Peripheral Interface Static RAM Transmission Control Protocol Time Division Multiple Access TX Data Universal Asynchronous Receiver-Transmitter User Datagram Protocol Universal Mobile Telecommunications System Universal Serial Bus UMTS Terrestrial Radio Access VC-TCXO WCDMA Voltage Controlled - Temperature Compensated Crystal Oscillator Wideband CODE Division Multiple Access 3G.G2-HW-10002-2 Advance Information Appendix Page 113 of 116 LISA-U1/LISA-H1 series - System Integration Manual Related documents u-blox LISA-U1/LISA-H1 series Data Sheet, Docu No 3G.G1-HW-10001 u-blox AT Commands Manual, Docu No WLS-SW-11000 ITU-T Recommendation V.24, 02-2000. List of definitions for interchange circuits between data terminal equipment (DTE) and data circuit-terminating equipment (DCE). http://www.itu.int/rec/T-REC-V.24-200002-I/en 3GPP TS 27.007 - AT command set for User Equipment (UE) (Release 1999) 3GPP TS 27.005 - Use of Data Terminal Equipment - Data Circuit terminating; Equipment (DTE - DCE) interface for Short Message Service (SMS) and Cell Broadcast Service (CBS) (Release 1999) 3GPP TS 27.010 - Terminal Equipment to User Equipment (TE-UE) multiplexer protocol (Release 1999) Universal Serial Bus Revision 2.0 specification, http://www.usb.org/developers/docs/
I2C-Bus Specification Version 2.1 Philips Semiconductors (January 2000), http://www.nxp.com/acrobat_download/literature/9398/39340011_21.pdf RFC3267 - Real-Time Transport Protocol (RTP) Payload Format and File Storage, Format for the Adaptive Multi-Rate (AMR) and Adaptive Multi-Rate Wideband (AMR-WB) Audio Codecs CENELEC EN 61000-4-2 (2001): "Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test". ETSI EN 301 489-1 V1.8.1: Electromagnetic compatibility and Radio spectrum Matters (ERM);
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements ETSI EN 301 489-7 V1.3.1 Electromagnetic compatibility and Radio spectrum Matters (ERM);
ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 7: Specific conditions for mobile and portable radio and ancillary equipment of digital cellular radio telecommunications systems (GSM and DCS) 3GPP TS 26.267 - Technical Specification Group Services and System Aspects; eCall Data Transfer; In-
band modem solution; General description (Release 9) GSM Mux Implementation Application Note, Docu No WLS-CS-11002 Firmware Update Application Note, Docu No WLS-CS-11001 SPI Interface application Note, Docu No 3G.G2-CS-11000
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[12]
[13]
[15]
[17]
[18]
Some of the above documents can be downloaded from u-blox web-site (http://www.u-blox.com). Revision history Revision Date Name Status / Comments
1 2 21/10/2010 sses 11/01/2011 sses Initial Release Thickness information added GPIO description improved 26/04/2011 lpah Update to Advance Information status and paste mask 3G.G2-HW-10002-2 Advance Information Related documents Page 114 of 116 LISA-U1/LISA-H1 series - System Integration Manual 3G.G2-HW-10002-2 Advance Information Page 115 of 116 LISA-U1/LISA-H1 series - System Integration Manual Contact For complete contact information visit us at www.u-blox.com u-blox Offices North, Central and South America u-blox America, Inc. Phone:
E-mail:
+1 (703) 483 3180 info_us@u-blox.com Regional Office West Coast:
Phone:
E-mail:
+1 (703) 483 3184 info_us@u-blox.com Technical Support:
Phone:
E-mail:
+1 (703) 483 3185 support_us@u-blox.com Headquarters Europe, Middle East, Africa u-blox AG Phone:
E-mail:
Support:
+41 44 722 74 44 info@u-blox.com support @u-blox.com Asia, Australia, Pacific u-blox Singapore Pte. Ltd. Phone:
E-mail:
Support:
+65 6734 3811 info_ap@u-blox.com support_ap@u-blox.com Regional Office China:
Phone:
E-mail:
Support:
+86 10 68 133 545 info_cn@u-blox.com support_cn@u-blox.com Regional Office Japan:
Phone:
E-mail:
Support:
+81 3 5775 3850 info_jp@u-blox.com support_jp@u-blox.com Regional Office Korea:
Phone:
E-mail:
Support:
+82 2 542 0861 info_kr@u-blox.com support_kr@u-blox.com Regional Office Taiwan:
Phone:
E-mail:
Support:
+886 2 2657 1090 info_tw@u-blox.com support_tw@u-blox.com and paste mask and paste mask 3G.G2-HW-10002-2 Advance Information Contact Page 116 of 116
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2011-05-26 | 1852.4 ~ 1907.6 | PCB - PCS Licensed Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2011-05-26
|
||||
1 | Applicant's complete, legal business name |
u-blox AG
|
||||
1 | FCC Registration Number (FRN) |
0019077858
|
||||
1 | Physical Address |
Zuercherstrasse 68
|
||||
1 |
Thalwil, N/A Ch-8800
|
|||||
1 |
Switzerland
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
h******@acbcert.com
|
||||
1 | TCB Scope |
B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
XPY
|
||||
1 | Equipment Product Code |
LISAU120
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
G****** C******
|
||||
1 | Title |
Certification Manager
|
||||
1 | Telephone Number |
+3904********
|
||||
1 | Fax Number |
+3904********
|
||||
1 |
g******@u-blox.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
SGS Taiwan Ltd.
|
||||
1 | Name |
W**** C******
|
||||
1 | Physical Address |
134, Wu Kung Road, Wuku Industrial Zone
|
||||
1 |
New Taipei City, 248
|
|||||
1 |
Taiwan
|
|||||
1 | Telephone Number |
02-22********
|
||||
1 | Fax Number |
02-22********
|
||||
1 |
W******@sgs.com
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 11/21/2011 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | PCB - PCS Licensed Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | LISA-U120 | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Single Modular Approval | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Single Modular Approval. Power out is conducted at the antenna terminal. ERP for part 22 is 0.384 W and EIRP for part 24 is 0.302 W using the specific antenna as shown within this application. This device is to be used only for mobile and fixed application. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC muti-transmitter product procedures. This module can only be used with a host antenna circuit trace layout design in strict compliance with the OEM instructions provided. Compliance of this device in all final host configurations is the responsibility of the Grantee. The use of a different trace layout other than approved requires a Class II Permissive Change or a New Grant as appropriate. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. OEM integrators must insure that the end user has no manual instructions to remove or install this module. For mobile and fixed operating configurations the antenna gain, including cable loss, must not exceed the requirements defined in 2.1091 for satisfying RF exposure compliance. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
SGS TAIWAN LTD.
|
||||
1 | Name |
N**** B****
|
||||
1 | Telephone Number |
886-2******** Extension:
|
||||
1 | Fax Number |
886-2********
|
||||
1 |
n******@sgs.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 22H | BC | 824.2 | 848.8 | 2.291 | 2.5 ppm | 245KGXW | |||||||||||||||||||||||||||||||||
1 | 2 | 24E | BC | 1850.2 | 1909.8 | 0.955 | 2.5 ppm | 243KGXW | |||||||||||||||||||||||||||||||||
1 | 3 | 22H | BC | 824.2 | 848.8 | 1.148 | 2.5 ppm | 250KG7W | |||||||||||||||||||||||||||||||||
1 | 4 | 24E | BC | 1850.2 | 1909.8 | 0.813 | 2.5 ppm | 243KG7W | |||||||||||||||||||||||||||||||||
1 | 5 | 24E | BC | 1852.4 | 1907.6 | 0.469 | 2.5 ppm | 4M06F9W | |||||||||||||||||||||||||||||||||
1 | 6 | 22H | BC | 826.4 | 846.6 | 0.632 | 2.5 ppm | 4M05F9W |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC