1/8/2021 U-LTE Quick Start Guide U-LTE Quick Start Guide Package Contents U-LTE Stand Mounting Bracket Double-Sided Adhesive Self-Tapping Screws (Qty. 2) Screw Anchors (Qty. 2) RP-SMA Cap System Requirements Linux, Mac OS X, or Microsoft Windows 7/8/10 Java Runtime Environment 1.8 or above recommended Web Browser: Google Chrome (Other browsers may have limited functionality) UniFi Controller software v5.12.x (or newer), available at: ui.com/download/unifi Hardware Overview https://dl.ui.com/qsg/U-LTE/U-LTE_EN.html 1/21 1/8/2021 U-LTE Quick Start Guide U-LTE Quick Start Guide RP-SMA Antenna Connector You can connect an optional external LTE antenna (not included). If you are not using an external antenna, then you can cover the connector with the RP-SMA Cap. This external antenna must be limited to no more than 6 dBi. Reset Button The Reset Button serves two functions:
Restart Press and release the Reset button quickly. Restore to Factory Default Settings Press and hold the Reset button for more than five seconds, until the display indicates Factory Reset. Secondary This Gigabit Ethernet port is used for bridging and can provide passive PoE to a https://dl.ui.com/qsg/U-LTE/U-LTE_EN.html 2/21 1/8/2021 U-LTE Quick Start Guide device. Main U-LTE Quick Start Guide This Gigabit Ethernet port is used to connect the power and should be connected to the LAN and DHCP server. 803.2at PoE+ can be provided by an 802.3at PoE+
switch, such as a UniFi PoE Switch. LCD Screen Displays status information, including the LTE signal strength. Installation Requirements Phillips screwdriver Wall-mounting (optional): drill with 6 mm drill bit For WAN failover:
UniFi Dream Machine, model UDM UniFi Security Gateway, model USG, USG-PRO-4, or USG-XG-8 UniFi cloud account Note: The U-LTE can only be adopted via remote access at: unifi.ui.com Activation of Ubiquiti LTE data plan For indoor applications, use Category 5 (or above) UTP cabling approved for indoor use. For outdoor applications, shielded Category 5 (or above) cabling should be used for all wired Ethernet connections and should be grounded through the AC ground of the power supply. We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial-grade, shielded Ethernet cable from Ubiquiti. For more details, visit: ui.com/toughcable WARNING: To reduce the risk of fire or electric shock, do not expose this product to rain or moisture. Note: Although the cabling can be located outdoors, the U-LTE itself should be housed inside a protective enclosure. Hardware Installation The U-LTE can be mounted in three ways:
https://dl.ui.com/qsg/U-LTE/U-LTE_EN.html 3/21 1/8/2021 U-LTE Quick Start Guide U-LTE Quick Start Guide Screw Mount Adhesive Mount Desktop Mount Screw Mount 1. 2. https://dl.ui.com/qsg/U-LTE/U-LTE_EN.html 4/21 1/8/2021 U-LTE Quick Start Guide U-LTE Quick Start Guide 3. https://dl.ui.com/qsg/U-LTE/U-LTE_EN.html 5/21 1/8/2021 U-LTE Quick Start Guide U-LTE Quick Start Guide 4. https://dl.ui.com/qsg/U-LTE/U-LTE_EN.html 6/21 1/8/2021 U-LTE Quick Start Guide U-LTE Quick Start Guide 5. https://dl.ui.com/qsg/U-LTE/U-LTE_EN.html 7/21 1/8/2021 U-LTE Quick Start Guide U-LTE Quick Start Guide Proceed to Connecting Ethernet. Adhesive Mount 1. 2. https://dl.ui.com/qsg/U-LTE/U-LTE_EN.html 8/21 1/8/2021 U-LTE Quick Start Guide U-LTE Quick Start Guide 3. https://dl.ui.com/qsg/U-LTE/U-LTE_EN.html 9/21 1/8/2021 U-LTE Quick Start Guide U-LTE Quick Start Guide Proceed to Connecting Ethernet. Desktop Mount https://dl.ui.com/qsg/U-LTE/U-LTE_EN.html 10/21 1/8/2021 U-LTE Quick Start Guide U-LTE Quick Start Guide Connecting Ethernet https://dl.ui.com/qsg/U-LTE/U-LTE_EN.html 11/21 1/8/2021 U-LTE Quick Start Guide Setup Overview You will do the following:
U-LTE Quick Start Guide Adopt the U-LTE in the UniFi Controller software. Set up your LTE account. You can manage your LTE subscription at:
account.ui.com/subscriptions If the primary WAN 1 or 2 goes offline, then the configured networks fail over to the U-LTE. Configuration 1. In the UniFi Controller, click the Devices tab. The U-LTE should be automatically detected and begin the setup wizard; proceed to step 2. Otherwise, select the U-LTE and click Adopt. 2. Click Setup LTE. https://dl.ui.com/qsg/U-LTE/U-LTE_EN.html 12/21 1/8/2021 U-LTE Quick Start Guide U-LTE Quick Start Guide 3. For your ui.com account, enter your email address or username and password. Select I agree to the Terms of Service and click Next. If you do not have a ui.com account, click Create a new ui.com account and follow the on-screen instructions. 4. For payment information, enter the following:
Credit card number Expiration month and year in this format: MM/YY CVC (Card Verification Code) on the back of your card Click Next. https://dl.ui.com/qsg/U-LTE/U-LTE_EN.html 13/21 1/8/2021 U-LTE Quick Start Guide U-LTE Quick Start Guide 5. The U-LTE will reboot. It can take up to 20 minutes to activate on the cellular network. Click Done to close this screen. Using the U-LTE To monitor data usage, click the U-LTE on the Devices screen. Its Properties panel will appear. https://dl.ui.com/qsg/U-LTE/U-LTE_EN.html 14/21 1/8/2021 U-LTE Quick Start Guide U-LTE Quick Start Guide Click the Settings icon to access the following:
Enable External Antenna If you attach an external antenna to the U-LTE, click this option. Enable PoE Passthrough If you have connected a secondary PoE device to the U-
LTE, click this option. LTE Data Plan An alert is initiated when 1 GB of data is used (by default). To change the data limit, click the Data Limit drop-down and select a different amount https://dl.ui.com/qsg/U-LTE/U-LTE_EN.html 15/21 1/8/2021 of data. Click Apply to save changes. U-LTE Quick Start Guide U-LTE Quick Start Guide When LTE failover is active, an alert will appear in the Properties panel and the Controllers list of alerts. Note: LTE failover is active by default. https://dl.ui.com/qsg/U-LTE/U-LTE_EN.html 16/21 1/8/2021 U-LTE Quick Start Guide U-LTE Quick Start Guide An alert will appear when LTE failover is activated or deactivated. Specifications Dimensions Weight Without Mounting With Mounting U-LTE 66 x 202.12 x 32.2 mm
(2.60 x 7.96 x 1.27") 200 g (7.06 oz) 316 g (11.15 oz) https://dl.ui.com/qsg/U-LTE/U-LTE_EN.html 17/21 1/8/2021 U-LTE Quick Start Guide U-LTE U-LTE Quick Start Guide Interfaces Networking Management Max. Power Consumption with PoE Passthrough PoE Out Power Method Power Supply Supported Voltage Range LCM LTE Category LTE Bands Antenna LTE 2.4 GHz 2.4 GHz Antenna Gain BT Operating Frequency Mounting Operating Temperature Operating Humidity Certifications
(2) 10/100/1000 RJ45 Ports WP7603 LTE Ethernet, Bluetooth 8.5W 16W*
48V Passthrough (Pins 1, 2+; 3, 6-) 802.3at
(Pairs 1, 2+; 3, 6-; Pairs 4, 5+; 7, 8-) UniFi PoE Switch 44 to 57VDC 1.54" Display Cat 4 B2/4/5/12
(1) 2x2
(1) 1x1 1.5 dBi 2400 - 2483.5 MHz Wall-Mount
-10 to 50 C (14 to 122 F) 5 to 95% Noncondensing FCC, IC, PTCRB, AT&T
* Requires 802.3at PoE+ switch. Safety Notices 1. Read, follow, and keep these instructions. 2. Heed all warnings. 3. Only use attachments/accessories specified by the manufacturer. WARNING: Do not use this product in location that can be submerged by water. WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning. https://dl.ui.com/qsg/U-LTE/U-LTE_EN.html 18/21 1/8/2021 U-LTE Quick Start Guide Electrical Safety Information U-LTE Quick Start Guide 1. Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturers label. Connection to a different power source than those specified may result in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed. 2. There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician. 3. This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet. a. Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire. b. The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death. c. Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment. d. Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection. e. Protective bonding must be installed in accordance with local national wiring rules and regulations. Limited Warranty ui.com/support/warranty The limited warranty requires the use of arbitration to resolve disputes on an individual basis, and, where applicable, specify arbitration instead of jury trials or class actions. Compliance FCC Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions. 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely https://dl.ui.com/qsg/U-LTE/U-LTE_EN.html 19/21 1/8/2021 U-LTE Quick Start Guide to cause harmful interference in which case the user will be required to correct the interference U-LTE Quick Start Guide at his own expense. This radio transmitter has been approved by FCC. ISED Canada CAN ICES-3(A)/NMB-3(A) This device complies with ISED Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
1. This device may not cause interference, and 2. This device must accept any interference, including interference that may cause undesired operation of the device. This radio transmitter has been approved by ISED Canada. CAN ICES-3(A)/NMB-3(A) Le prsent appareil est conforme aux CNR dISDE Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
1. lappareil ne doit pas produire de brouillage;
2. lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. Le prsent metteur radio a t approuv par ISDE Canada. IMPORTANT NOTE Radiation Exposure Statement This equipment complies with radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. AVIS IMPORTANT Dclaration sur lexposition aux rayonnements Cet quipement est conforme aux limites prvues pour lexposition aux rayonnements dans un environnement non contrl. Lors de linstallation et de la mise en fonctionnement de lquipement, assurez-vous quil y ait une distance minimale de 20 cm entre llment rayonnant et vous. Cet metteur ne doit tre install proximit daucune autre antenne ni daucun autre metteur, et ne doit tre utilis conjointement aucun autre de ces appareils. https://dl.ui.com/qsg/U-LTE/U-LTE_EN.html 20/21 1/8/2021 U-LTE Quick Start Guide Online Resources U-LTE Quick Start Guide 2021 Ubiquiti Inc. All rights reserved. https://dl.ui.com/qsg/U-LTE/U-LTE_EN.html 21/21