all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 3.37 MiB | September 08 2020 | |||
1 |
|
Internal Photos | Internal Photos | 436.58 KiB | September 08 2020 | |||
1 |
|
External Photos | External Photos | 658.61 KiB | September 08 2020 | |||
1 |
|
Label and label location | ID Label/Location Info | 97.32 KiB | September 08 2020 | |||
1 | Block diagram | Block Diagram | September 07 2020 | confidential | ||||
1 |
|
FCC Confidentiality request letter | Cover Letter(s) | 83.08 KiB | September 08 2020 | |||
1 |
|
Power of Attorney Letter | Cover Letter(s) | 16.00 KiB | September 08 2020 | |||
1 | Operation Description | Operational Description | September 08 2020 | confidential | ||||
1 | Schematic | Schematics | September 08 2020 | confidential | ||||
1 |
|
Test Setup Photos | Test Setup Photos | 136.75 KiB | September 08 2020 | |||
1 |
|
Test report-DXX | Test Report | 2.06 MiB | September 08 2020 |
1 | User Manual | Users Manual | 3.37 MiB | September 08 2020 |
WWDZWU Wireless Water Detector Technology for Humanity Ubitech Ltd. Page: 1 Version: 0.1.4 INTRODUCTIONS 1.1 Whats Z-Wave 1.2 About Custos WWD FEATURES & SPECIFICATIONS 2.1 2.2 Hardware Specifications 2.3 Software Specifications Physical Specifications 3. WHAT INSIDE IN THE BOX Custos WWD Unit 3.1 3.2 Remote Water Detection Probe UNDERSTANDING CUSTOS WWD 4.1 Connectors & Interfaces CHANGE THE BATTERY 5.1 5.2 How to Change Battery Battery Support 1. 2. 4. 5. 6. 7. ACTION SENSOR & INDICATORS BEHAVIOR 6.1 6.2 Visual Indicator 6.3 Sound Indicator 3-axis Action Sensor HOW CUSTOS WWD WORKS 7.1 Action Sensor Ubitech Ltd. Date:26-JULY-2020 INDEX 8. HOW CUSTOS WWD WORKS 8.1 Water Detection Probes 8.2 Built-in Water Detection Probe 8.3 Remote Water Detection Probe 9. WORKING MODE SUPPORT Shipping Mode 9.1 9.2 Standalone 9.3 Mesh Network 9.4 Water Leak Sensor & Alarm 10. SETUP & PHYSICAL INSTALLATION 10.1 10.2 Disable Shipping Mode Connect the Remote Sensor Probe 11. USER INTERFACE BEHAVIORS 11.1 Event Status 12. SETUP Z-WAVE NETWORK 12.1 12.2 12.3 12.4 Check Custos WWD Status Add Custos WWD into Z-Wave Network Remove Custos WWD from Z-Wave Network Factory Default Reset 13. BATTERY LEVEL 13.1 Battery Level Report 13.2 Battery Level Check Page: 2 0.1.4 Version:
Date:26-JULY-2020 14. WATER LEAK ALARM 14.1 Water Leak Detection & Alarm 14.2 Water Leak Alarm Cancellation 15. TEMPERATURE SENSOR REPORT 15.1 Temperature Report 16. Z-WAVETM SOFTWARE DEFINITIONS 16.1 16.2 16.3 16.4 16.5 16.6 16.7 16.8 16.9 16.10 16.11 17.1 17.2 17.3 17.4 17.5 17.6 17.7 Z-Wave PlusTM Info Version CC Manufacturer Specific Notification CC Indicator CC Basic CC Mapping Wake up CC Association Group Info (AGI) Support Command Class in NIF Configuration CC Smart Start Labeling Z-Wave Terminology Event Status System Event 3-Axis Accelerometer Processing Network Event Battery Status Water Leak Alarm Status 17. APPENDIX Page: 3 0.1.4 Ubitech Ltd. Version:
Date:26-JULY-2020 Ubitech Ltd. Version:
Page: 4 0.1.4 1 INTRODUCTION 1.1 Whats Z-Wave Z-Wave is international wireless protocol used for Smart Home. Its a mash network technology to ensure reliable two-way communication with each other. Z-Wave provides interoperability and security from multivendor to make sure Certificated products work within Z-Wave network. All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the communication. 1.2 About Custos WWD Custos Wireless Water Detector Custos WWD detects Water Leakage with long battery operation lifespan, super tiny form factor detects water from either in body detection probe on 4 sides as well as optional remote wired water detection probe. It is a perfect companion for Custos BVS to work in concerto as a complete solution to close water valve once WWD detected water leak (need proper set up on App or gateway configuration). It gets Z-Wave Plus Certification means it can be worked with other Z-Wave certified gateways or end-devices from other manufacturers. Ubitech Ltd. Page: 5 Version: 0.1.4 2 FEATURES & SPECIFICATIONS Date:26-JULY-2020 2.1 Physical Specifications Parameter Model No. Dimensions Weight Body Color Water Detection method Waterproof and Dustproof Operation Temperature Relative Humidity Value WWDZWU (US) / WWDZWE (EU) 21.6 x 21.6 x 67.5mm WWD Unit: 52g White Conduction IPX5 14~122 F (-10 ~ +50C) 8% ~ 80%
2.2 Hardware Characteristic Parameter Z-Wave Module Z-Wave RF Distance Region Frequency Water Leak Sensor Temperature Sensor Action Sensor LED Indicator Power Supply Battery Life Value ZGM130S037HGN1 40m (Indoor) / 120m (Outdoor) US: 908.4 & 916MHz, FCC CFR47 Part 15.249 EU: 868.42 & 869.85MHz Dual Water Detection Probes Built-in & Remote Temperature Sensor Range from -40C to +125C / (-40F to +257F) 3-Axis Accelerometer Sensor 3 colors LED. (Green, Yellow & Red) ER14250 - Battery 3.6V 1200mAH Standby: ~3.uA over 10 Years Ubitech Ltd. Version:
Page: 6 0.1.4 Date:26-JULY-2020 2.3 Software Specifications Parameter Wireless Technology Value Z-Wave Z-Wave Certification Type Z-Wave Plus v2 Certification Z-Wave SDK Version v7.13.5 0x04 (ROUTING_SLAVE) 0x06 (ROLE_TYPE_SLAVE_SLEEPING_REPORTING) Notification 0x07 (GENERIC_TYPE_SENSOR_NOTIFICATION) 0x01 (SPECIFIC_TYPE_NOTIFICATION_SENSOR) Non-Security, S2 Unauthenticated and S2 Authenticated Support: After powering on, Smart Start is auto activated if its out of Z-Wave network Support: Firmware upgrade support via RF, Over The Air (OTA) Support 5 Groups. Lifeline, Built-in Water Leak Alarm, Remote Water Leak Alarm, Overheat & Underheat Factory Default Reset Support: Device Locally Reset Z-Wave Library Z-Wave Role Type Device Type Generic Device Type Specific Device Type Security Class Smart Start Firmware Update Association Ubitech Ltd. Version:
Page: 7 0.1.4 3 WHAT INSIDE IN THE BOX Standard Custos Wireless Water Detector (WWD) package comes with below items 3.1 3.2 Custos WWD Main Unit x 1 A Remote Water Detection Probe x 1 (Optional) B Date:26-JULY-2020 B A Ubitech Ltd. Version:
Page: 8 0.1.4 Date:26-JULY-2020 4 UNDERSTANDING CUSTOS WWD 4.1 Connectors & Interfaces Terminology a 3D Action Sensor b Display Indicators c Sound Indicator d Temperature Sensor e Leak Sensor #1 f Leak Sensor #2 g Z-Wave QR Code Description 3-axis Action Sensor 3 Colors LED Green, Yellow & Red Buzzer Built-in Temperature Sensor Built-in Water Detection Probe Remote Water Detection Probe 3.5mm jack m Battery Z-Wave QR Code & PIN Code Terminology h SN & Product Details i j Battery Cover Screw k Battery Cover l Battery Contact Dust Cover Description Z-Wave QR Code & PIN Code 3.6V h SN &
Product Info g Z-Wave QR Code & PIN f Remote Leak Sensor Jack k Battery Cover i Dust Cover b LED Indicator Page: 9 0.1.4 e Built-in Water Detection Probe a 3D Action Sensor c Buzzer d Sensor Temperature Ubitech Ltd. Version:
j Battery Cover Screw l Battery Contact m Battery 5 CHANGE THE BATTERY Date:26-JULY-2020 Battery Support
- Model: ER14250
- Voltage: 3.6V
- Type: Lithium 1200mAh 5.1 5.2 How to change battery
- Remove the screws of battery cover and batter cover, (Figure A)
- Replace new ER14250 battery
- Put the rubber waterproof rubber o-range (Figure B)
- Put the battery cover and align with two battery metal contacts then tighten the screws. Gasket Battery metal Contacts Figure A Ubitech Ltd. Version:
Figure B Page: 10 0.1.4 Date:26-JULY-2020 6 ACTION SENSOR & INDICATORS BEHAVIOR 6.1 6.2 6.3 3-axis Action Sensor
- Built-in 3-Axis Accelerometer for gesture recognition by detecting a series of movements,
- 3-axis movement supports detection (X, Y & Z axis). Visual Indicator
- 3 Colors LED: GREEN, YELLOW & RED
- ON Event: ON, quick blinking and slow blinking Sound Indicator
Buzzer: Long & short beep sound. Ubitech Ltd. Version:
Page: 11 0.1.4 7 HOW 3-AIXS ACTION SENSOR WORKS Date:26-JULY-2020 7.1 3-axis Actions Sensor Gesture Recognition Procedure
End-user can use built-in 3-axis Accelerometer to replace physical touchable key, it can detect any movement very sensitive, end-user use a series of action to enable some defined function, such as below functions i. ii. iii. iv. To wake up from Custos WWD from sleep mode, Inclusion & Exclusion, Factory Default Reset, Send out Battery Report,
- WWD supports three types of gesture movements, with Position-Movements as below, a Vertical-Vertical
To enable Gesture Recognition, please following below procedure, b Vertical-Horizontal Gesture Recognition Procedure c Horizontal-Horizontal Ubitech Ltd. Version:
Page: 12 0.1.4 8 HOW WATER LEAK SENSOR WORKS Date:26-JULY-2020 8.1 Water Detection Probes Custos WWD supports two Water Detection Probes Built-in & Remove, 8.2 Built-in Water Detection Probe
- WWD has special recess which helps induce Water run through it, to create effective detection by probes from both end To achieve better result, please put the WWD on the floor flatly 8.3 Remote Water Detection Probe
To make sure Sensor Probe works properly show as below pictures, please make sure insert the Remove Sensor Probe tightly and there is no any gap allowed between 3.5mm jack and housing.
- Water will be gone through and absorbed by this slot when water is leaking Ubitech Ltd. Version:
Page: 13 0.1.4 9 SETUP & PHICAL INSTALLATION 9.1 Activate WWD from Shipping Mode (For Brand New WWD only) i. ii. To trigger Built-in Water Detection Probe for 10 seconds with YELLOW LED flash 10 times, Figure A Until the success UI signal show up, Green LED & Buzzer sound 1 time Date:26-JULY-2020 Trigger Built-in Leak Sensor Figure A 9.2 Connect the Remote Sensor Probe (Optional) i. ii. iii. Remove Dust Cover. (Please do not remove Dust Cover if Remote Sensor Probe not installed) Figure B Insert the 3.5mm jack of Remote Water Detection Probe tightly. Figure C Place the Custos WWD on the floor horizontally Figure B Figure C Dust Cover Page: 14 Date:26-JULY-2020 10 WORKING MODE SUPPORT 10.1 Shipping Mode (Deep Sleep Mode)
- By default, Custos WWD is set in Shipping Mode to keep it in deep sleep to conserve battery for transportation & warehousing, in this time all functions will be disabled until unlocked it from Shipping Mode. End-customer must activate the device from Shipping Mode before set up. 10.2 Standalone Mode 10.3 Mesh Network Mode
If Custos WWD is not belongs to any Z-Wave Network and it unlocked from Shipping Mode. It supports Classic Inclusion / Smart Start to add into Z-Wave Network.
- Custos WWD is added into a Z-Wave Network and it can join full benefits of Z-Wave technology.
- Supported function as Water Leak Detection, Temperature Report, Smart Start, Classic Inclusion, Exclusion & Factory Default Reset.
- Custos WWD also can associate with Custos BVS to shut off the Water Valve when detected Water Leak. 10.4 Water Leak Sensor & Alarm
- Water Leak Alarms refer to two Water Detection Probes Built-in & Remote Remote Probe Built-in Probe Page: 15 11 USER INTERFACE BEHAVIORS Date:26-JULY-2020 11.1 Event Event status Below table shows simple UI Event status result, for more detail please refer to item 17.2 17.7, Action LED Remark Completed / Okay Fail Timeout Waked up Standalone Network n/a n/a n/a After triggered by 3-axis sensor Green flash x2 Red flash x3 Red flash x2 Yellow ON x1 Green ON x1 Buzzer Sound 2 times 3 times 2 times 1 time 1 time Device Mode Shipping Normal Triggering Built-in Sensor Probe Yellow x1 @ Sec Red x1 @ Sec n/a 1 time @ second Event executed without problem / will go to next step Even failed and will stop to execute next step Even timeout and will stop to execute next step Waked up and 3-axis sensor is ready. In Standalone mode. Waked up and 3-axis sensor is ready. In Mesh Network Mode Device is in Shipping Mode; all functions are disabled Device is in Normal Mode; all functions are enabled Page: 16 12 SETUP Z-WAVE NETWORK Date:26-JULY-2020 12.1 Check Network Status:
- By default, Custos WWD does not belong to any Z-Wave Network, before adding WWD into Z-Wave Network, you have to make sure Custos WWD is in Standalone Mode, otherwise you have to perform Factory Default Reset refer to 12.4, Network Status Check If its not in Standalone Mode, please perform Factory Default Reset - refer to 12.4 or Remove it from Z-Wave Network refer to 12.3 12.2 Add Custos WWD into Z-Wave Network:
- Custos WWD supports Security 2 Command Class while a Security S2 enabled controller is needed. It supports Smart Start and Classic Inclusion, For adding Custos WWD into Z-Wave Network, end-user can use Smart Start for Classic Inclusion,
12.2.1
- To enable Smart Start, below methods can be used Smart Start:
i. Scan the Z-Wave QR Code or entering PIN Code or DSK String into S2 Enabled Gateway, please refer to item 16.11 Smart Start Labeling, ii. Wakeup Custos WWD by shaking it until the Yellow LED ON and Buzzer Sound x1, Setup In Gateway Setup In End-Device To enable Security S2 in Z-Wave Gateway, please refer to Gateways user manual. Page: 17 12.2.2 Classic Inclusion / Add Device:
Custos WWD also support Classic Inclusion, i. Set your Z-Wave Gateway into Inclusion Mode / Add Device processing. ii. Use Vertical-Horizontal movement in WWD to activate Classic Inclusion Mode, iii. Follow below procedure to start Classic Inclusion procedure in Custos WWD Custos WWD Inclusion Process Date:26-JULY-2020 Please process the Inclusion Procedure again if WWD shows any error #3 / #5 /#7 with RED LED ON & Buzzer Sound. 12.3 Remove Custos WWD from Z-Wave Network:
Custos WWD also support Classic Inclusion, set your Z-Wave Gateway into Add device. i. Set your Z-Wave Gateway into Exclusion Mode / Remove Device processing, ii. Use Vertical-Horizontal movement in WWD to activate Exclusion Mode, iii. Follow below procedure to start Exclusion procedure in Custos WWD, Custos WWD Exclusion Process Please process the Exclusion Procedure again if WWD shows any error #3 / #5 /#7 with RED LED ON & Buzzer Sound. Page: 18 12.4 Factory Default Reset: (Horizontal/Horizontal Movement + Trigger Leak Sensor 10s) 12.4.1 To remove Custos WWD without involve gateway in Exclusion / Remove device operation and WWD will reset all setting to Factory Date:26-JULY-2020 Default Setting as below. a. b. c. Remove the WWD from Z-Wave Network;
Delete the association setting;
Restore the configuration settings to the default. 12.4.2 To perform Factory Default Reset i. Use Horizontal-Horizontal movement in WWD to activate Factory Default Reset processing, ii. Trigger Built-in Water Leak Sensor for 10 seconds Buzzer Sounds & LED flashing 5 times iii. Following below procedure to start Factory Default Reset function in Custos WWD Horizontal-Horizontal Movement Trigger Built-in Leak Sensor Custos WWD Factory Default Reset Procedure Please process the Factory Default Reset Procedure again if WWD shows any error #3 / #5 /#7 with RED LED ON & Buzzer Sound. Page: 19 13 Battery Level Date:26-JULY-2020 13.1 Battery Level Report 13.2
- The Battery Level Report can be show on Custos WWD and report to Gateway after waked up every time. Battery Level Check
User Vertical-Vertical movement in WWD to activate Battery Level Check processing, Following below procedure to start Battery Level Check, Therere three result of Battery Level UIs, i. Battery Full = 61 100%
ii. Battery Fair = 31 60%
iii. Battery Low < 30%
Custos WWD Battery Level Check Procedure Page: 20 14 Water Leak Sensor & Alarm Date:26-JULY-2020 14.1 Water Leak Detection & Alarm 14.2 Water Leak Alarm Cancellation
Custos WWD can report Water Leak by Built-in & Remote Water Detection Probe through Notification CC, Built-in Water Leak Alarm Sends to Association Group 2, Remote Water Leak Alarm Sends to Association Group 3 Water Leak Alarm Cancellation action sets Basic SET to Associated Group and it can be configured with Configuration CC, i. Built-in Water Detection Probe sends Basic SET to Association Group 2, ii. Remote Water Detection Probe sends Basic SET to Association Group 3 Page: 21 15 Temperature Sensor Date:26-JULY-2020 15.1 Temperature Report (waked up by 3-axis accelerometer or auto wake up interval)
- By default, Custos WWD will send report to Gateway after waked up every time.
- Custos WWD reports to gateway the temperature unit F in US version and C for other frequency versions. Page: 22 16 Z-WAVE SOFTWARE DEFINITIONS Date:26-JULY-2020 Value 2 0x06 (ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_SLEEP_REPORTING) 0x00 (ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVEPLUS_NODE) 0x0C05 (ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_WATER_ALARM) 0x0C05 (ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_WATER_ALARM) 16.1 Z-Wave Plus Info Parameter Z-Wave Plus Version Role Type Node Type Installer Icon Type User Icon Type 16.2 Version CC Parameter Z-Wave Protocol Library Type Z-Wave Protocol Version Z-Wave Protocol Sub Version Firmware 0 Version Firmware 0 Sub Version Hardware Version Number of firmware targets 16.3 Manufacturer Specific Parameter Manufacturer ID 1 Manufacturer ID 2 Product Type ID 1 Product Type ID 2 Product ID 1 Product ID 2 Value 0x02 0x70 0x02 0x01 0x01 0x0B Value 0x03 0x07 0x0D 0x01 Z-Wave Chip Major Firmware Version 0x0C Z-Wave Chip Minor Firmware Version 0x01 0x00 Page: 23 Date:26-JULY-2020 Notification Notification Events / State Description 16.4 Notification CC Type Heat Alarm 0x04 State idle Overheat detected Underheat detected State idle Water leak detected State idle Battery fluid is low 0x00 0x02 0x06 0x00 0x02 0x00 0x11 Notification value for the state variable going to idle (V5) No Location Support Event No Location Support Event Notification value for the state variable going to idle (V5) No Location Support Event Notification value for the state variable going to idle (V5) Water Alarm 0x05 0x08 Power Management 16.5 Parameter Indicator ID Property ID Indicator CC Value 0x50 = (Node Identify) 0x03 = (On/Off Periods) 0x04 = (On/Off Cycles) 0x05 = (On time within an On/Off period) 16.6 Basic CC Mapping of Water WWD Basic Command Class does not map to any Command Class 16.7 Wake Up CC Wake Up Interval Capabilities Report Value Parameter 0x000014 Min Wake Up Interval (Seconds) Max Wake Up Interval (Seconds) 0x015180 Default Wake Up Interval (Seconds) 0x001C20 0x000014 Wake Up Interval Step (Seconds) Time 20 Seconds 86400 Seconds (24 Hours) 7200 Seconds (2 Hours) 20 Seconds Page: 24 16.8 Association Group Info (AGI) Association Name Group Node Count 5 1 Lifeline Date:26-JULY-2020 Function
- Device Reset Locally Notification
- Sensor Binary Report
- Indicator Report
- Sensor Multilevel Report Temperature Auto report based on Configuration Parameter 0x22 Setting.
- Battery Report
- Heat Alarm Notification Report (0x04) 0x00 = State idle 0x02 = Overheat no location support -
0x06 = Underheat no location support
- Water Alarm Notification Report (0x05) 0x00 = State idle 0x02 = Water leak detected no location support
- Power Management Notification (0x08) 0x00 = State Idle 0x11 = Battery Fluid is low
2 3 4 5 Built-in Leak Sensor Probe Remote Water Detection Probe Overheat Alarm Underheat Alarm
(Freeze) 5 5 5 5
- Basic Set
- Basic Set
- Basic Set
- Basic Set 0x00 = IDEL / CANCEL (Based on Configuration Parameter 0x41 Setting) 0xFF = TRIGGERED (Based on Configuration Parameter 0x40 Setting) 0x00 = IDEL / CANCEL (Based on Configuration Parameter 0x43 Setting) 0xFF = TRIGGERED (Based on Configuration Parameter 0x42 Setting) 0x00 = IDEL / CANCEL (Based on Configuration Parameter 0x45 Setting) 0xFF = TRIGGERED (Based on Configuration Parameter 0x44 Setting) 0x00 = IDEL / CANCEL (Based on Configuration Parameter 0x47 Setting) 0xFF = TRIGGERED (Based on Configuration Parameter 0x46 Setting) Page: 25 16.9 Supported Command Classes In NIF Command Class Version Not added Non-secure added Security 2 added Secure Date:26-JULY-2020 ZWAVEPLUS_INFO SENSOR_BINARY ASSOCIATION MULTI_CHANNEL_ASSOCIATION ASSOCIATION_GRP_INFO NOTIFICATION TRANSPORT_SERVICE VERSION MANUFACTURER_SPECIFIC DEVICE_RESET_LOCALLY INDICATOR POWERLEVEL SECURITY SECURITY_2 SUPERVISION FIRMWARE_UPDATE_MD SENSOR_MULTILEVEL - Temperature CONFIGURATION APPLICATION STATUS WAKE_UP BATTERY 2 2 3 4 3 8 2 3 2 1 3 1 1 1 1 5 11 4 1 2 1 Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Non-Secure Support
Support
Support Support Support
Support Support Support Support Support
Support Support Support Support Support
Support Support Support Support Support Support Page: 26 16.10 Configuration CC Note: No Bulk Support equals to True. It will return an Application Rejected Request Command when receiving Configuration Bulk Set or Get (if received without Supervision encapsulation). It will reset all its configuration parameters if either manually reset to factory default or receives a Configuration Default Reset Command. It will NOT modify or reset any configuration parameter when being included or excluded of a Z-Wave network Date:26-JULY-2020 Sensor Function 1 Byte Bit Field False False 0x00 (0) 0x0F (15) 0x0F (15) False Min Value Max Value Default Value Advanced 0x10 (16) Sensors Function Set Sensors Function Enable / Disable Size Format Read only Altering capabilities Water Leak Probes & Temperature Function Set Disable / Enable *(Default all enabled) Value Bit 0 Bit 1 Bit 2 Bit 3 0x11 (17) Water Leak Cancellation Basic SET Water Leak Probes Cancellation for AG2 AG3 Size Format Read only Altering capabilities Configure Water Leak Cancellation Basic SET for Built-in (AG2) / Remote Sensor (AG3) Probes, related parameters 0x41 & 0x43 Value 0x00 (0) 0x01 (1) Function Built-in Water Detection Probe *(Default Enabled) Remote Water Detection Probe *(Default Enabled) Overheat Detection *(Default Enabled) Freeze Detection *(Default Enabled) Function Send Basic SET when Water Alarm Cancelled Either Built-in or Remote Water Detection Probe Send Basic SET when Water Alarm Cancelled Built-in And Remote Water Detection Probe Min Value Max Value Default Value Advanced 1 Byte Enumerated False False 0x00 (0) 0x01 (1) 0x01 (1) False Parameter No. Name Info Properties Description Parameter No. Name Info Properties Description Page: 27 Battery Function Date:26-JULY-2020 Parameter No. 0x20 (32) Name Info Properties Description Battery Level Change Auto Report Battery Level Change Value to auto report Size Format Read only Altering capabilities Configure Battery Level Change Value to auto report *(Default 10% change to auto report) Value 0x00 (0) 0x01 (1) 0x02 (2) Function Disable Auto Temperature Report Report Celsius C unit Report Fahrenheit F unit 1 Byte Unsigned Integer False False Min Value Max Value Default Value Advanced 0x00 (0) 0x63 (99) 0x0A (10) False Parameter No. 0x21 (33) Name Info Properties Description Battery Threshold Level Report Battery Lower Threshold Level Report Size Format Read only Altering capabilities Configure Battery Lower Threshold Level Report *(Default 30%, the buzzer also will be disabled at the same time) Value 0x01 (1) 0x63 (99) Function Battery Lower Threshold Valve Report *(Default 30%) 1 Bytes Unsigned Integer False False Min Value Max Value Default Value Advanced 0x01 (1) 0x63 (99) 0x1E (30) False Temperature Sensor 1/3 Parameter No. 0x30 (48) Name Info Properties Description Temperature Report Unit Configure Temperature Report Unit Size Format Read only Altering capabilities Configure Temperature Unit report. The default unit is depended on Regional Frequency Setting. *(By default, US=F and EU=C) Value 0x00 (0) 0x01 (1) 0x02 (2) Function Disable Auto Temperature Report Report Celsius C unit Report Fahrenheit F unit Min Value Max Value Default Value Advanced 1 Bytes Enumerated False False 0x00 (0) 0x02 (2) 0x02 (2) False Page: 28 Date:26-JULY-2020 Temperature Sensor 2/3 Parameter No. 0x31 (49) Name Info Properties Description Temperature Level Change Report Temperature Level Change to auto report Size Format Read only Altering capabilities Configure Temperature Level Change to auto report. Higher byte 0x00 represents Celsius C unit, 0x01 represents Fahrenheit F unit Value 0x0000 ~ 0x00FF 0x0100 ~ 0x01FF 0x0000 (0) = 0C / 0x0100 (0) = 0F 0x00FF (255) = 255C) / 0x01FF (511) = 255F 0x0004 (4) = 4C / 0x0104 (260) = 4 F False 2 Bytes Unsigned Integer False False Min Value Max Value Default Value Advanced Function From 0C to 255C From 0F to 255F Parameter No. 0x32 (50) Name Info Properties Temperature Value Offset Report Temperature Value Offset Report Set 2 Bytes Size Unsigned Integer Format Min Value Max Value 0x0000 (0) = 0C / 0x0100 (0) for 0F 0x10FF (255) = -255C / 0x11FF (4607) =
-255F 0x0000 (0) = 0C / 0x0100 (256) for 0F False Description False False Read only Altering capabilities Configure Temperature Value Offset (Bytes 0xxx = Positive Value; 1xxx = Negative Value & x0xx = C; x1xx = F) Value 0x0000 ~ 0x00FF 0x1001 ~ 0x10FF 0x0100 ~ 0x01FF 0x1101 ~ 0x11FF Function From 0C to 255C From -1C to -255C From 0F to 255F From -1F to -255F Default Value Advanced Parameter No. 0x33 (51) Name Info Properties Description Overheat Trigger Value Overheat Trigger Value SET Size Format Read only Altering capabilities Configure Overheat Trigger Value. (Higher byte 0x00 represents Celsius C unit, 0x01 represents Fahrenheit F unit) Value 0x0000 ~ 0x00FF 0x0100 ~ 0x01FF 2 Byte Unsigned Integer False False Min Value Max Value Default Value Advanced Function From 0C to 255C From 0F to 255F 0x0000 (0) = 0C / 0x0100 (0) = 0F 0x00FF (255) = 255C / 0x01FF (511) = 255F 0x0028 (40) = 40C / 0x0168 (360) = 104F False Page: 29 Date:26-JULY-2020 Temperature Sensor 3/3 Parameter No. 0x34 (52) Name Info Properties Description Parameter No. 0x35 (53) Name Info Properties Description Parameter No. 0x36 (54) Name Info Properties Description Overheat Cancellation Value Overheat Cancellation Value auto report Size Format Read only Altering capabilities Configure Overheat Cancellation Value Set. (Higher byte 0x00 represents Celsius C unit, 0x01 represents Fahrenheit F unit) Value 0x0000 ~ 0x00FF 0x0100 ~ 0x01FF 0x0000 (0) = 0C / 0x0100 (0) = 0F 0x00FF (255) = 255C / 0x01FF (511) = 255F 0x001E (30) = C / 0x0156(342) = 86 F False 2 Byte Unsigned Integer False False Min Value Max Value Default Value Advanced Function From 0C to 255C From 0F to 255F Freeze Trigger Value Configure Freeze Trigger Report value Size Format Read only Altering capabilities Configure Freeze Trigger Report Value. (Higher byte 0x00 represents Celsius C unit, 0x01 represents Fahrenheit F unit) Value 0x0000 ~ 0x00FF 0x0100 ~ 0x01FF 2 Bytes Unsigned Integer False False Min Value Max Value Default Value Advanced Function From 0C to 255C From 0F to 255F 0x0000 (0) = 0C / 0x0100 (0) = 0F 0x00FF (255) = 255C / 0x01FF (511) = 255F 0x0000 (0) = 0C / 0x0168 (360) = 104F False Freeze Recover Value Configure Freeze Recover Report Value Size Format Read only Altering capabilities Configure Freeze Recover Report Value. (Higher byte 0x00 represents Celsius C unit, 0x01 represents Fahrenheit F unit) Value 0x0000 ~ 0x00FF 0x0100 ~ 0x01FF 2 Bytes Unsigned Integer False False Min Value Max Value Default Value Advanced Function From 0C to 255C From 0F to 255F 0x0000 for C / 0x0100 for F 0x00FF (255) =255C / 0x01FF (511) = 255F 0x0002 (2) =2C / 0x0156(342) = 86 F False Page: 30 Date:26-JULY-2020 Parameter No. Name Info Properties Description Parameter No. Name Info Properties Description Parameter No. Name Info Properties Description Association Group 1/3 1 Byte Enumerated False False Min Value Max Value Default Value Advanced Function Disable Basic Set (Send nothing) Basic Set ON (0xFF) Basic Set OFF (0x00) 0x40 (64) AG2 - Built-in Water Leak Trigger Built-in Water Leak Trigger Basic SET Size Format Read only Altering capabilities Configure Association Group 2 Basic Set value when Built-in Water Leak triggered Value 0x00 (0) 0x01 (1) 0x02 (2) 0x41 (65) AG2 - Built-in Water Leak Cancellation Built-in Water Leak Cancellation Basic SET Size Format Read only Altering capabilities Configure Association Group 2 Basic Set value when Built-in Water Leak Cancelled Value 0x00 (0) 0x01 (1) 0x02 (2) 0x42 (66) AG3 - Remote Water Leak Trigger Remote Water Leak Trigger Basic SET Size Format Read only Altering capabilities Configure Association Group 3 Basic Set value when Remote Water Leak triggered Value 0x00 (0) 0x01 (1) 0x02 (2) Function Disable Basic Set (Send nothing) Basic ON (0xFF) Basic OFF (0x00) Function Disable Basic Set (Send nothing) Basic Set ON (0xFF) Basic Set OFF (0x00) Min Value Max Value Default Value Advanced Min Value Max Value Default Value Advanced 1 Byte Enumerated False False 1 Byte Enumerated False False 0x00 (0) 0x02 (2) 0x01 (1) False 0x00 (0) 0x02 (2) 0x00 (0) False 0x00 (0) 0x02 (2) 0x01 (1) False Page: 31 Date:26-JULY-2020 Parameter No. Name Info Properties Description Parameter No. Name Info Properties Description Parameter No. Name Info Properties Description Association Group 2/3 1 Byte Enumerated False False Min Value Max Value Default Value Advanced Function Disable Basic Set (Send nothing) Basic ON (0xFF) Basic OFF (0x00) 0x43 (67) AG3 - Remote Water Leak Cancellation Remote Water Leak Cancellation Basic SET Size Format Read only Altering capabilities Configure Association Group 3 Basic Set value when Remote Water Leak cancelled Value 0x00 (0) 0x01 (1) 0x02 (2) 0x44 (68) AG4 - Overheat Trigger Value Overheat Trigger Value Basic SET 1 Byte Size Enumerated Format False Read only False Altering capabilities Configure Association Group 4 Basic Set value when Overheat Triggered Value 0x00 (0) 0x01 (1) 0x02 (2) 0x45 (69) AG4 - Overheat Recover Value Overheat Recover Value Basic SET Size Format Read only Altering capabilities Configure Association Group 4 Basic Set value when Overheat Recovered Value 0x00 (0) 0x01 (1) 0x02 (2) Function Disable Basic Set (Send nothing) Basic ON (0xFF) Basic OFF (0x00) Function Disable Basic Set (Send nothing) Basic ON (0xFF) Basic OFF (0x00) Min Value Max Value Default Value Advanced Min Value Max Value Default Value Advanced 1 Byte Enumerated False False 0x00 (0) 0x02 (2) 0x00 (0) False 0x00 (0) 0x02 (2) 0x00 (0) False 0x00 (0) 0x02 (2) 0x00 (0) False Page: 32 Date:26-JULY-2020 Parameter No. Name Info Properties Description Parameter No. Name Info Properties Description Parameter No. Name Info Properties Description Association Group 3/3 1 Byte Enumerated False False 0x46 (70) AG5 - Freeze Trigger Value Freeze Trigger Value Basic SET Size Format Read only Altering capabilities Configure Association Group 5 Basic Set value when Freeze Triggered Value 0x00 (0) 0x01 (1) 0x02 (2) 0x47 (71) AG5 - Freeze Recover Value Freeze Recover Value Basic SET Size Format Read only Altering capabilities Configure Association Group 5 Basic Set value when Freeze Recovered Value 0x00 (0) 0x01 (1) 0x02 (2) Function Disable Basic Set (Send nothing) Basic ON (0xFF) Basic OFF (0x00) Function Disable Basic Set (Send nothing) Basic ON (0xFF) Basic OFF (0x00) 1 Byte Enumerated False False Min Value Max Value Default Value Advanced Min Value Max Value Default Value Advanced 0x00 (0) 0x02 (2) 0x00 (0) False 0x00 (0) 0x01 (1) 0x00 (0) False Notification Report 0x50 (80) Resend Water Leak Notification Time Resend Water Leak Notification Time Set Size Format Read only Altering capabilities Configure Resend Water Leak Notification time in minutes during Water Leak is triggered *(Default 0x00 = not resend) Value 0x00 0x01 ~ 0x1E 1 Byte Unsigned Integer False False Min Value Max Value Default Value Advanced 0x00 (0) 0x1E (30) 0x00 (0) False Function Do not resend 1 - 30 Minutes Page: 33 Date:26-JULY-2020 User Interface Parameter No. Name Info Properties Description Parameter No. Name Info Properties Description 1 Byte Bit Field False False Min Value Max Value Default Value Advanced 0x60 (96) Buzzer Related Function Actions Buzzer Related Function Actions Set Size Format Read only Altering capabilities Configure Buzzer Function Disable / Enable with device action. *(Default 0x03, 0=Disable; 1=Enable) Value Bit 0 Bit 1 0x61 (97) Buzzer Sound Saving Mode Sound works first 3S Water Leak Detected Size Format Read only Altering capabilities Configure Buzzer Sound works for first 3 Seconds only when Water Leak is detected if Saving Mode enabled *(Default 0x01=Eanble) Value 0x00 0x01 Function Disable Saving mode (Buzzer sound works during whole Water Leak is detected) Enable Saving mode (Buzzer function only works 3s when Water Leak is detected) Function Buzzer Enable responds with GSensor in action *(Default 1 = Eanbled) Buzzer Enable responds with Water Leak Detection *(Default 1 = Enabled) Min Value Max Value Default Value Advanced 1 Byte Bit Field False False 0x00 (0) 0x01 (1) 0x01 (1) False 0x00 (0) 0x03 (3) 0x03 (3) False Page: 34 16.11 Smart Start Labeling Custos WWD comes with QR Code including PIN Code and Full DSK string for Smart Start and theyre located as below locations, PIN Code with QR Code on WWD housing
QR Code with full DSK string printed on Packing Box, the first 5 digits is PIN code for Smart Start use. Date:26-JULY-2020 PIN Code: 12345 12345-xxxxx-xxxxx-xxxxx-x xxxx-xxxxx-xxxxx-xxxxx
17 APPENDIX Page: 35 Terminology, all events and operations details including action key event, LED and Buzzer status. 17.1 Z-Wave Terminology Z-Wave Functionality Inclusion Documentation Terminology Add Description The process of adding a node to Z-Wave Network Remove The process of removing a node from Z-Wave Network Date:26-JULY-2020 Exclusion 17.2 Event Status Event Event Okay Fail Timeout 17.3 System Event Event Power On Okay Device Mode Shipping Normal Action LED Remark n/a n/a n/a Green flash x2 Red flash x3 Red flash x2 Event executed without problem / will go to next step Even failed and will stop to execute next step Even timeout and will stop to execute next step Buzzer Sound 2 times 3 times 2 times Action LED Remark YG x1 Yellow x1 @ Sec Red x1 @ Sec Buzzer Sound 1 time n/a 1 time @ second Power Up Triggering Built-in Sensor Probe After triggered by 3-axis sensor System Power On Okay after battery installed Device is in Shipping Mode, all functions are disabled Device is in Normal Mode, all functions are enabled Waked up and 3-axis sensor is ready. In Standalone mode. Waked up and 3-axis sensor is ready. In Mesh Network Mode Waked up Standalone Network Yellow ON x1 Green ON x1 1 time 1 time 17.4 3-Axis Accelerometer Processing Event Action Position Recognizing Gesture Recognizing n/a n/a LED Green flashing G & R flashing Buzzer Sound n/a n/a Remark Position is under recognizing; timeout is 5 seconds Gesture is under recognizing; timeout is 10 seconds Page: 36 17.5 Network Event Event Action LED Remark Inclusion / Exclusion Factory Default Reset 1st phase 2nd phase Processing Built-in Leak sensor Red flashing 3-axis sensor Green ON x1 Yellow flashing OTA FW Upgrade Starting Processing OTA upgrade procedure Green flash x2 GYR flashing 17.6 Battery Status Event Date:26-JULY-2020 In processing, LED keep flashing until event finished Waked up and 3-axis sensor is ready. In Standalone mode. Waked up and 3-axis sensor is ready. In Mesh Network Mode Being to start OTA firmware upgrade OTA is in progressing, LED keep flashing until OTA finished. Action LED Remark Battery Level Full Fair Low Battery Level check by 3-axis sensor procedure Green flash x3 Yellow flash x3 Red flash x3 Battery level is full. over 60%
Battery level is fair. between 30% to 60%
Battery level is low under 30%
17.7 Water Leak Alarm Status Event Action Normal Saving mode Trigger Water Detection Probe Yellow x1 @ sec Green x1 @ sec Buzzer keeps beep sound continually at 1 sound per second. Only 3 beep sounds in first 3 seconds at 1 sound per second. LED Remark Buzzer Sound 1 time @ second 3 times only Water Leak Alarm Buzzer Sound n/a 1 time 1 time 2 times n/a Buzzer Sound 3 times 3 times 3 times Page: 37 Date:26-JULY-2020 FCC Statement This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
--Reorient or relocate the receiving antenna.
--Increase the separation between the equipment and receiver.
--Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
--Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Radiation Exposure Statement This device complies with RF radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Page: 38
1 | Label and label location | ID Label/Location Info | 97.32 KiB | September 08 2020 |
J 8
=2 2
=8
=8 3 See Se
= cs
=8 a
eT aS TMitintialinl TTT ee re 5 Mii
II
Li ST ne UOT CTC COO UL a UL i ey Ca a VAL aa a Ya MMMM MMMM
1 | FCC Confidentiality request letter | Cover Letter(s) | 83.08 KiB | September 08 2020 |
CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 Date: 2020/09/02 TO WHOM IT MAY CONCERN Pursuant to Paragraphs 0.457 and 0.459 of the Commissions Rules (47 C.F.R.) and Section 552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products:
FCC ID 2AUZX-WWDZWU For the product stated above, we request that the following information be held confidential;
Model name WWDZWU Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos Users Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, Name:
Company: Ubitech Limited Address:
C.K. Sze Phone:
Fax:
E-Mail:
Flat 12, 7/F Block A, Hi-Tech Industrial Centre,5-21 Pak Tin Par Street, Tsuen Wan, N.T. Hong Kong
(852) 94719203
(852) 94719203 ck@ubitech.hk
1 | Power of Attorney Letter | Cover Letter(s) | 16.00 KiB | September 08 2020 |
Flat 12, 7/F Block A, Hi-Tech Industrial Centre,5-21 Pak Tin Par Street, Tsuen Wan, N.T. Hong Kong Tel: (852) 94719203 Fax: (852) 94719203 Ubitech Limited Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 To whom it may concern:
9/6/2020 We, Ubitech Limited the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2AUZX-WWDZWU including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, Name:
Company: Ubitech Limited Address:
C.K. Sze Phone:
Fax:
E-Mail:
Flat 12, 7/F Block A, Hi-Tech Industrial Centre,5-21 Pak Tin Par Street, Tsuen Wan, N.T. Hong Kong
(852) 94719203
(852) 94719203 ck@ubitech.hk
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2020-09-08 | 916 ~ 916 | DXX - Part 15 Low Power Communication Device Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2020-09-08
|
||||
1 | Applicant's complete, legal business name |
UBITECH LIMITED
|
||||
1 | FCC Registration Number (FRN) |
0028951275
|
||||
1 | Physical Address |
Unit 12, 7F Block A, Hi-Tech Industrial Centre 5-21 Pak Tin Par Street, Tsuen Wan, NT
|
||||
1 |
Unit 12, 7F Block A, Hi-Tech Industrial Centre
|
|||||
1 |
Hong Kong, N/A
|
|||||
1 |
Hong Kong
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
j******@eurofins.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2AUZX
|
||||
1 | Equipment Product Code |
WWDZWU
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
C******** S******
|
||||
1 | Title |
CEO
|
||||
1 | Telephone Number |
(852)********
|
||||
1 | Fax Number |
(852)********
|
||||
1 |
c******@ubitech.hk
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Wireless Water Detector | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Shenzhen Global Test Service Co., Ltd.
|
||||
1 | Name |
J**** L******
|
||||
1 | Telephone Number |
0755-********
|
||||
1 |
l******@gtscert.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 908.42 | 908.42 | |||||||||||||||||||||||||||||||||||||
1 | 2 | 15C | 916 | 916 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC