all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 2 |
|
User-Manual | Users Manual | 1.95 MiB | April 16 2021 | |||
1 2 |
|
Internal photos | Internal Photos | 1.69 MiB | April 16 2021 | |||
1 2 |
|
External photos | External Photos | 812.26 KiB | April 16 2021 | |||
1 2 |
|
Label and location | ID Label/Location Info | 68.53 KiB | April 16 2021 | |||
1 2 |
|
Agent Authorization Rev 1.0 | Cover Letter(s) | 15.41 KiB | April 16 2021 | |||
1 2 | BOM | Parts List/Tune Up Info | April 16 2021 | confidential | ||||
1 2 |
|
Declaration Letter of Model Difference | Cover Letter(s) | 13.55 KiB | April 16 2021 | |||
1 2 |
|
FCC Short & Long Term Confidentiality | Cover Letter(s) | 65.84 KiB | April 16 2021 | |||
1 2 |
|
LCS210302066AEA GSM | Test Report | 5.18 MiB | April 16 2021 | |||
1 2 |
|
LCS210302066AEBSAR FCC REPORT | RF Exposure Info | 4.05 MiB | April 16 2021 | |||
1 2 |
|
LCS210302066AEC WCDMA | Test Report | 2.85 MiB | April 16 2021 | |||
1 2 | Operation Description | Operational Description | April 16 2021 | confidential | ||||
1 2 | SCH | Schematics | April 16 2021 | confidential | ||||
1 2 |
|
Test Setup photo | Test Setup Photos | 318.06 KiB | April 16 2021 | |||
1 2 |
|
Test Setup photos | Test Setup Photos | 135.07 KiB | April 16 2021 | |||
1 2 | Tune Up Procedure | Parts List/Tune Up Info | April 16 2021 | confidential | ||||
1 2 | block diagram | Block Diagram | April 16 2021 | confidential | ||||
1 2 |
|
LCS210302066AED 15.231 | Test Report | 1.28 MiB | April 16 2021 | |||
1 2 | Operation Description | Operational Description | April 16 2021 | confidential | ||||
1 2 | Schematic | Schematics | April 16 2021 | confidential | ||||
1 2 | Tune up Info | Parts List/Tune Up Info | April 16 2021 | confidential |
1 2 | User-Manual | Users Manual | 1.95 MiB | April 16 2021 |
Tracking Solutions Embedded Antenna design GPS&Wireless solutions Provider 1 Part Number: NB-5 Doc Type : User Manual Doc Id: WI-RD-E-054 Reversion : V1.0 Copyright 2020 San Jose Technology, Inc. All Rights Reserved. This document contains information that is the property of SANAV. This document may not be copied, reproduced, reduced to any electronic medium or machine readable form, or otherwise duplicated, and the information herein may not be used, disseminated or otherwise disclosed, except with the prior written consent of SANAV. www.etek.com.tw U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. Contents Specifications ................................................................................................................ 3 NB5 Function Overview ........................................................................................... 4 NB5 Tracker Installation ........................................................................................ 8 Cutting Tools ................................................................................................................ 12 NB5 SMS Command Quick Setting .................................................................. 15 STEP 1: Set up Username/Password (Optional) ....................................... 17 STEP 2: Set up Phone Book and Security Phone Number (Optional)19 STEP 3: Set up HA ID .......................................................................................... 20 SETP 4: Set up RF Detection (Optional) ...................................................... 21 SETP 5: Set up RF Power ................................................................................... 22 STEP 6: Set up APN for 3G Service ............................................................... 23 STEP 7: Set up URL and TCP/UDP IP Address ........................................... 24 STEP 8: Set up Route for Data Transmission ............................................. 26 STEP 9: Set up Auto Report (Optional) ........................................................ 27 Step 10: Request IMEI Number ...................................................................... 28 Appendix 1: Report Data Format ..................................................................... 29 Appendix 2: Tracker Event List ......................................................................... 31 SMS Command Introduction............................................................................... 32 How to Use ER Command for erase the flash .......................................... 33 How to Restart The Device .................................................................................. 34 Setting of Restart The Device ............................................................................ 35 Use POll Command for acquiring the position ......................................... 36 Set up FBR Command for Fiber Strap ........................................................... 37 Use REED Command for Cover Tamper ........................................................ 38 Command for Toggling the Buzzer and vibrator .................................... 39 Power Saving Mode Setup ................................................................................... 41 AES128 encryption function setting .............................................................. 42 TCP acknowledge function setting ................................................................. 43 Set up Low Power reminder ............................................................................... 44 GSM Cell Information Setting ............................................................................ 45 Firmware upgrade Over The Air (FOTA) function ................................. 46 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 2 www.unictron.com www.sanav.com www.etek.com.tw GPS GPS Module:
Sensitivity:
RF RF Module:
Frequency:
Sensitivity:
System Power Specifications GSM GSM Module:
uBlox SARA U201 GSM Frequency:
3G: 800/ 850/ 900/ 1900/ 2100MHz GSM: 850 / 900/ 1800/ 1900MHz 3G Transmission:
Power class 3 (24 dBm) for WCDMA/HSDPA/HSUPA mode u-blox G8030 support NMEA0183
-164 dBm Channels/ Frequency:
72 Channels/ GPS/QZSS/GLONASS TTFT(Hot/Warm/Cold):
Cold/Warm <26 seconds Hot <1 second Position Accuracy:
2.5 meter (CEP, 50%, 24 hours static, -130dBm, SEP: <3.5m) U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. RIFO TI CC1101/ Modulation: FSK 436.8MHz
-116dBm/0.6kbaud Control system Alarm/ RF/ GSM Antenna type:
Embedded GPS/ GSM/ RF antenna External Power Output:
DC 9V/ 2A/ 18W (Standard) Battery Power:
3.7V DC Li-Ion Battery, 2300mAh Charge 3 hours battery to support the device to operate more Battery life:
than 30 hours
(based on 1 report/1 minutes, No alarm) Environment Condition Charging temperature:
0C ~ +40C
-10C ~ +55C Relative Humidity:
5% ~ 95%, non-condensing Working/Storage temperature:
Mechanics Data Size:
Strap Size:
Weight:
80mm (L) x 68mm (W) x 42mm (H) 375mm (L) x 30mm (W) x 4.5mm (T) 200g (Including strap and batteries) 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 3 www.unictron.com www.sanav.com www.etek.com.tw Waterproof:
IP68 NB5 Function Overview 1. Basic Function Introduction NB5 is multi-functional electronic monitoring ankle bracelet with GPS/3G/RF monitoring technology. With electronic monitoring technology, you have ability to reliability track users location. NB5 utilizes GPS and 3G services to upload the RMC sentences containing latitude, longitude, date and time to assigned monitoring center. It is specially designed for the intensive tracking applications, such as offender tracking or life security. Note: In the house, please install remote monitoring unit and signal amplifier to enhance signal strength if necessary. Remote monitoring unit monitors users movement and an alarm is automatically sent to assigned monitoring center if the user violates the regulations. U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. 2. Main features Built-in buzz and vibration alarm Support low battery / strap cut / equipment case opened Reusable and adjustable fiber optical strap Entering/leaving restriction zoom alarm IP68 waterproof Weak signal alarm monitoring unit 100% charge/charging/ low-charge LED indication ; Power status of NB5 reports to remote 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 4 www.unictron.com www.sanav.com www.etek.com.tw Charge 3 hours to provide above 30-hour operation (each report/1 minutes, no general alarm) 3. Front View GPS CH GSM STATUS U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. LED (from left to right):
1. GPS Positioning LED (Blue):
While the device gets GPS fixed, the GPS light will stay on. 2. GSM LED (Red):
While the device gets GSM fixed or in normal operation, the GSM light will flash every 3 seconds. In case of weak GPS signal, the GSM LED will flash every second. When GSM enter the power-saving mode, the GSM light will stay off. 3. Status LED (Orange):
While the device is sending the reports or SMS message, the Status LED will flash one time. In case the device is at low battery, the LED will flash every second. If an alarm has occurred, the Status LED will be quick flash. 4. CH charge LED (Green):
While the device connects to the charger, the CH LED will flash every second. Once the device is fully 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 5 www.unictron.com www.sanav.com www.etek.com.tw charged, the CH LED will stay on. Unplug the charger when the device is fully charged. In this situation, CH charger LED will be off. 5. Charge Socket (Red circle):
Please make sure to use San Jose original charger and charging pack to protect your equipment. U n i c t r o n T e c h n o o g e s C o r p
. l i A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 6 www.unictron.com www.sanav.com www.etek.com.tw 4. Back Cover 5. Wall Charger U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 7 www.unictron.com www.sanav.com www.etek.com.tw NB5 Tracker Installation Note: The device must be fully charged prior to installation. Remember to wear a pair of socks for comfortable attaching. 1. Circle the users leg with strap and installation height of NB5 will be 8-10cm from an outer ankle. U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. Back Cover Edge Line 2. Circle the users leg with strap and determine the length of the strap that leaves approximately 20-30 mm (2-3 scales) of space between the uses leg and the strap for comfortable to wear. 3. For example, Back Cover Edge Line is at the block 14; you should cut the block 16 which is spare space for the strap clip. Cutting line 4. Use the specific cutting tool to cut the strap not the scissors. Please refer to the document of cutting tool below. Use the dedicated strap cutter to cut the strap to corresponded length as measured at step 2. Note:
The cut edge of strap should be flat to have good contact of fiber optical detection. 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 8 www.unictron.com www.sanav.com www.etek.com.tw 5. Please note that the cutting line should be on the groove between two scales for easy cutting and wearing purpose. 6. While cutting the strap by using the dedicated strap, it should proceed with 3 stages cutting procedures. Keep cutter and strap at 90-degree angle to make sure that the cutting edge should be flat.
(1) 1ST stage: Cut slowly from strap edge to 2/5 of strap width (as marked 1 of right picture).
(2) 2nd Stage: Continue to cut 1/5 of strap width, where is the fiber optical wire, by one-time cut to avoid from bumpy cutting edge
(as marked 2 of right picture).
(3) 3rd Stage: Continue to cut 2/5 of strap width (as marked 3 of right picture). U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 9 www.unictron.com www.sanav.com www.etek.com.tw 7. Cut procedures are completed. 8. Put up the Jelly cover at the end of strap. Please refer to NB5 Jelly cover 9. Fix the strap clip at the end of strap. assembly SOP. 10. Insert the strap with strap clip into the socket chamber at rear cover right side. Press the strap deeply into the chamber. Make sure the strap can not be pull-off from the strap chamber. Snap Snap U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 10 www.unictron.com www.sanav.com www.etek.com.tw 11. Activated. Start tracking. 12. While using wall charger, aim the charger connector (female) to NB5 charge socket (male), push till the end to lock the device. Unplug the wall charger in correct direction to avoid from charge socket or charger malfunction. 13. Connected and charged. U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. 11 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com www.unictron.com www.sanav.com www.etek.com.tw Cutting Tools 1. Make sure that the front side of the cutting tool faces to you and that the straps entrance direction. The spare blades are restored in the red rectangle. U n i c t r o n T e c h n o o g e s C o r p
. l i A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. 2. Check that the blade is right on the block that should be cut. 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 12 www.unictron.com www.sanav.com www.etek.com.tw 3. After making sure the location is right, push the top of cutting tool to cut the strap 4. Exchange the blade if needed. Release the screw ant then remove the blade. Note that releasing completely the screw is not Notice the direction of the blade since we need to install the spare blade on the same direction necessary. later. U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 13 www.unictron.com www.sanav.com www.etek.com.tw 5. Install the blade. Please make sure the edge of the blade is inside the white area on the Push the top of cutting tools to the bottom so that the blade is back to the right place and cutting tool. screw it up. U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 14 www.unictron.com www.sanav.com www.etek.com.tw U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. NB5 SMS Command Quick Setting SMS Command setting 1. Any setup command must be started with a # sign and ended up with a * sign. Please note that all the characters which include #, * and comma (,) should be HALFWIDTH form. 2. Please be aware of the upper (capital)/lower cases when entering the SMS command. 3. While entering any SMS command, note that NO SPACE is allowed between the characters, comma and signs in the SMS. correct. number. 4. The comma (,) can be abbreviated if no further setup required for the command besides Set up APN for 3G Service. Please refer to the examples of Set up Auto Report. 5. The device will update setting only when the password, username and setup command are all If the command is not valid, a failure report is going to be sent to the users cell phone. 6. If the device set up the authorized number, SMS commands should be sent via authorized 7. If the command is valid, a success report is going to be sent to the users cell phone. 8. Please make sure that the Call-Forward function of SIM card is turned off and Call-Display 9. Please make sure that the PIN-Code of SIM card if off. If the PIN-Code is necessary, use 0000 function of SIM card is turned on. as PIN-Code. SETP 0: Send the Alarm-OFF Command STEP 1: Set up Username/Password (Optional) STEP 2: Set up Phone Book and Security Phone Number (Optional) STEP 3: Set up HA ID SETP 4: Set up RF Detection Range Test (Optional) SETP 5: Set up RF Power STEP 6: Set up APN for 3G Service STEP 7: Set up Route for Data Transmission STEP 8: Set up URL and TCP/UDP IP Address STEP 9: Set up Auto Report (Optional; default setting 60 seconds/each report) STEP 10: Request IMEI Number 15 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com www.unictron.com www.sanav.com www.etek.com.tw U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. SETP 0: Send the Alarm-Off Command Once the events such as strap violation and device tamper are triggered, NB5 will send the reports with the alarm message followed by the beep sound and vibration. This command is used to deactivate the alarm status, and then the device will be detecting the events. Setup Format#<User Name>, <Password>, <Function Mode>*
Example#username,0000,alarmoff*
(1) Turn on buzz sound when alarming function (Function Code 19). Example: #username,0000,19,1,1 (0 means to disable it)*
The 1st parameter is for toggling the buzz alarm function. The 2nd is for toggling the vibration alarm function
(2) Once the events are triggered, deactivate all alarm by sending Alarm-Off commands if its necessary. Example: #username,0000,alarmoff*
Note: If triggered events occurred, vibration and buzz alarm can be stop temporarily by sending Alarm-Off commands. However, afterward, vibration and buzz alarm will be generated again if triggered events continuously occurred. SMS Text
username 0000 alarmoff
Situation Setup Succeeds Description Start sign. Default ID of BRACELET. Default password. End sign. Message Reply If you have changed the Username, please use the updated one. If you have changed the password, please use the updated one. Function to turn off all alarms Table: Alarm-off Setup Format Description
[username] +, Alarm is set off. Table: Alarm-off Setup Response Description 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 16 www.unictron.com www.sanav.com www.etek.com.tw STEP 1: Set up Username/Password (Optional) Set up Username setting. Generally, SMS command execution needs correct user name (I.D) with password, or it will remain the same The SMS command default user name is username. It can be changed by following the command format. For example, entering the SMS command as the following allows user to change the user name from username to a new user name abc. Only enter new command with new user name after it has been changed. Setup format#<username>, <Password>, <Function Code>, <New username>*
Example#username,0000,1, abc *
SMS Text Description Start sign. username Default ID of Bracelet. 0000 Default password of Bracelet. If you have changed the username, please use the updated one. U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. If you have changed the password, please use the updated one. Mode 1 defines user name setup mode. New defined user name. At the maximum of 16 letters which can only be a~z,A~Z,0~9, @ - _ /
End sign. Table: Username Setup Format Description Situation Message Reply Setup Succeeds
[username] + Device username is updated. Setup Fail
[username] + Device username setup fail!
Incorrect username or
[username] + command error command format Table: Username Setup Response Description
1 abc
17 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com www.unictron.com www.sanav.com www.etek.com.tw U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. Set up Password Generally, SMS command execution needs correct user name with password, or it will remain the same setting. The SMS command default password is 0000. It can be changed by following the command format. For example, entering the SMS command as the following allows user to change the password from 0000 to a new password 1111. Only enter command with new password will be valid for setting change after it has been changed. Setup format#<username>, <Password>, <Function Code>, <new Password>, <new Password>*
Example#username,0000,2,1111,1111*
SMS/ COTA Command Description username Default ID of the device. If you have changed the username, please use the updated one. Start sign. Default password. Reconfirm the password End sign. If you have changed the password, please use the updated one. Mode 2 defines the password setup mode. New password (Please note at the maximum of 4 number) Table: Password Change Format Description Situation Message Reply Setup Succeeds
[username] + Device Password is updated. Setup Fail
[username] + Password setup Fail!
Table: Password Change Response Description
0000 2 1111 1111
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 18 www.unictron.com www.sanav.com www.etek.com.tw
5 STEP 2: Set up Phone Book and Security Phone Number (Optional) Security Phone Number allows limited administrators to manage and change the settings of the bracelet. When the Security Phone Number is set, even the User Name and Password are correct, if the setup phone number is not matched, the setup or any change will be invalid. Please be careful when setting up Security Phone Number. mode. GSM signal or something. Security Phone Number also is the number that is used when the router is set as HTTP/SMS, TCP/SMS or SMS If the router of the device is set as those above, the device will send the reports via SMS to the Security Phone Number as the backup router in the occasion in which the device cannot send out the reports due to the poor The maximum set of Security Phone Number is 3. We can simply set up one number or two numbers as well. Setup format: #<User Name>, <Password>, <Function Mode>, <Security Number1>, <Security Number2>,
<Security Number3>*
Example#username,0000,5,+886123456789*
Example#username,0000,5,+886123456789,+886123456789*
Example#username,0000,5,+886123456789,+886123456789,+886123456789*
U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. Note that both adding and not adding the + sign in front of the cellular phone number(s) are both acceptable, Using this command to empty the phone book:
Example#username,0000,5,0,0,0*
while the + sign should precede the national code. SMS/ COTA Command Description Start sign. username Default ID of the device. 0000 Default password. If you have changed the user name, please use the updated one. If you have changed the password, please use the updated one. Mode 5 defines the Phone Book and the Security Number setup mode.
+886123456789 The Security Phone number 1 and Phone number 1 you would like to assign to the
+886123456789 The Security Phone number 1 and Phone number 1 you would like to assign to the
+886123456789 The Security Phone number 1 and Phone number 1 you would like to assign to the device. device. device. 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 19 www.unictron.com www.sanav.com www.etek.com.tw End sign. Table: Security Phone Number Setup Format Description Situation Message Reply Setup Succeeds
[username] + Device phone book is updated. Table: Security Phone Number Setup Response Description STEP 3: Set up HA ID The bracelet (HA) ID is set for identification. The ID number ranges from 1 to 9999. The ID will be shown in the reports. U n i c t r o n T e c h n o o g e s C o r p
. l i A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. imei=356496041252545&rmc=$GNRMC,020733.00,A,2457.80794,N,12125.53854,E,0.012,,170720,,,A*67, AUTO,I0200,,,,9999,M14,4182mV,33,1.48,466,1,24A5,13E16E9,30,FFFF,29,10613,26,19,FFFF,195,10613,26 NB5s HA ID is for the purpose that user can quickly recognize which bracelet (NB5) is and manage it more
E.g.
,19 easily. Setup Format#<username>, <Password>, <Function Mode>, <HA ID Number>*
Example#username,0000,haid,200*
SMS Text Description
Start sign. username Default ID of Bracelet. If you have changed the Username, please use the updated one. 0000 Default password of Bracelet. If you have changed the password, please use the updated one. haid 200
Mode haid defines HA ID setup mode. HA ID number. Ranges from 1 to 9999. End sign. Table: HA ID Setup Format Description Situation Message Reply Setup Succeeds
[username] + setup OK. Device ID setting is updated. Table: HA ID Setup Response Description 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 20 www.unictron.com www.sanav.com www.etek.com.tw
0000 rf433 0/1 0/1
SETP 4: Set up RF Detection (Optional) This command is for the bracelet with RF capability. Once the RF Detect function is turned on, the device can communicate with the Home Unit. This command can be used for site survey when installing Home Unit. When RF test mode (the 2nd parameter) is turned on, the bracelet will beep when it receives the RF signal from Home Unit. Sometimes we have to know the boundary of RF433 detection; therefore its an easier way to test the communication between the two devices via the beep sound without observing the report in the server especially at the first time of installation of the two units. After having tested it, we can turn the beep sound off. There are two types of command, the short one is for toggling the function quickly and the long one is for setting Setup Format of short type#<User Name>, <Password>, <Function Mode rf433>, <0/1 (Detection U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. Setup Format of long type#<User Name>, <Password>, <Function Mode rf433>, <0/1 (Detection On/OFF)>, up all the parameter On/OFF)>*
Example#username,0000,rf433,1*
< Sound Enable/Disable>*
Example#username,0000,rf433,1,0*
SMS Text Description Start sign. username Default ID of Bracelet. If you have changed the Username, please use the updated one. Default password of Bracelet. If you have changed the password, please use the updated one. Function Mode of RF Detection 0: Disable RF detection in Bracelet 1: Enable RF detection in Bracelet. Bracelet will transmit information to the Home Unit nearby which Bracelet is paired to. (default) 0: Turn off buzzer when receiving RF signals from Home Unit (default) 1: Turn on buzzer when receiving RF signals from Home Unit for RF range test End sign. Table: RF Detection Setup Format Description Situation Message Reply Setup Succeeds
[username] + setup OK. Device RF433 setting is updated. Table: RF Detection Setup Response Description 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 21 www.unictron.com www.sanav.com www.etek.com.tw SETP 5: Set up RF Power The ankle bracelet RF transmit power can be set for Home Unit curfew range adjustment. There are totally 8 levels of RF transmit power that can be set. The stronger the RF transmit power is, the wider the curfew range would be. We always adjust the level of RF transmit power for both the bracelet and Home Unit. RF channel defines that all the equipments including NB5 (bracelet), HU3 (Home Unit) should use the same channel to communicate each other. In some case there are a number of set of equipments in the same place
(such as more than 10 sets), we can set them in groups and configure each set to different channel, and it will reduce the possibility of disturbing each other. Generally we dont have to change the default channel. Setup Format#<username>, <Password>, <Function Mode>, <RF Power Level>, <RF Channel>, <RF Distance U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. Mode>*
Example#username,0000,rfpw,5,10*
SMS Text Description
Start sign. username Default ID of Bracelet. If you have changed the Username, please use the updated one. 0000 Default password of Bracelet. rfpw 5 10
If you have changed the password, please use the updated one. Mode rfpw defines RF power level setup mode. RF power level. Ranges from 1(min) to 8(max). (The default is 5) RF channel. Ranges from 1 to 150. (The default is 10) End sign. Table: RF Power Setup Format Description Situation Message Reply Setup Succeeds
[username] + setup OK. Device RF power level is updated. Table: RF Power Setup Response Description 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 22 www.unictron.com www.sanav.com www.etek.com.tw STEP 6: Set up APN for 3G Service Access Point Name (APN) is a protocol that typically allows a user's device to access the internet using the l l s p e c i f i c a t i o n s s u b j e c t t o c h For uploading the data to a server in the internet, a set of GPRS APN depending on your GSM network is required. a n g e Various GSM network provides different GPRS APN settings. Please ask your GMS carrier about the APN settings. w mobile phone network. It is a network identifier used by a mobile device when connecting to a GSM carrier. The carrier will then examine this identifier to determine what type of network connection should be created. i t h If the user name, password and DNS of APN are not required, just leave the parameters empty (no space). User o u t n o t i c e
. can follow the Setup Format below to setup the APN that is provided by your GSM carrier. A U n i c t r o n T e c h n o o g e s C o r p
. i l Setup Format: #<username>, <Password>, <Function Mode>, <APN name>, <APN username>, <APN password>, <APN DNS>*
Example1:#username,0000,3,internet,guest,guest,172.20.2.10*
characteristics. Leave the parameters empty (no space) if other parameters are not required. Example2:#username,0000,3,internet,,,*
Note1: The total length of APN name, APN username, APN Password, and APN DNS should be less than 70 Note2: Some PREPAID PHONE CARD SIM modules do not enable or even not support GPRS service. Please consult with GSM carrier for further information. SMS/ COTA Command Description
username Start sign. Default ID of the device. If you have changed the user name, please use the updated one. 0000 Default password. If you have changed the password, please use the updated one. Mode 3 defines the APN setup mode. APN Name APN User name (optional) APN Password (optional) 172.20.2.10 APN DNS (optional)
End sign. Table: APN Setup Format Description 3 internet guest guest 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 23 www.unictron.com www.sanav.com www.etek.com.tw U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. Situation Message Reply Setup Succeeds
[username] +, Device GPRS APN is updated. Table: APN Setup Response Description STEP 7: Set up URL and TCP/UDP IP Address Set up URL This SMS command is for setting up a specified URL (Uniform Resource Locator) or IP address of HTTP protocol server where the bracelet will transmit GPS (GPRMC) positioning data to for real time GPS tracking as route of the device is set as HTTP mode. E.g. Use function code 4 to setup the URL as the following command to configure URL for HTTP. Setup Format#<User Name>, <Password>, <Function Mode 4>, <URL>*
Example#username,0000,4, http://www.sanavtw.com/uploadM1.php *
SMS Text Description
Start sign. username Default ID of Bracelet. 0000 Default password of Bracelet. If you have changed the Username, please use the updated one. If you have changed the password, please use the updated one. Mode 4 defines URL setup mode. http://www.sanavtw.com Default domain name and the sign ? is not allowed to write in the area.
/uploadM1.php End sign. Table: URL Address Setup Format Description Situation Message Reply Setup Succeeds
[username] + Device IP/Domain is updated. Setup Fail
[username] + IP/Domain setup Fail!
Incorrect password
[username] + Password setup Fail!
Incorrect username or
[username] + command error command format Table: URL Address Setup Response Description 4
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 24 www.unictron.com www.sanav.com www.etek.com.tw U n i c t r o n T e c h n o o g e s C o r p
. l i A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. Set up TCP/UDP IP Address This SMS command is for setting up a specified TCP or UDP protocol based server where the bracelet will transmit GPS (GPRMC) positioning data for real time GPS tracking as route of the device is set as TCP or UDP mode. E.g. Use function code 18 to setup the URL as the following command to configure URL for TCP or UDP. Setup Format#<User Name>,<Password>,<Function Mode>,<TCP/IP Address><Port>*
Example#username,0000,18,202.39.31.127:13337*
SMS Text Description
Start sign. username Default ID of Bracelet. 0000 Default password of Bracelet. If you have changed the Username, please use the updated one. If you have changed the password, please use the updated one. Mode 18 defines IP address setup mode for TCP or UDP. 202.39.31.127:1337 The specified TCP/UDP IP address and port. End sign. Table: TCP/UDP IP Address Setup Format Description Situation Message Reply Setup Succeeds
[username] +", setup ok. Device TCP/IP is updated."
Setup Fail
[username] +", TCP/IP setup fail!"
Incorrect username or
[username] + Username or Password error password Incorrect function mode
[username] + command error Table: TCP/UDP IP Address Setup Response Description 18
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 25 www.unictron.com www.sanav.com www.etek.com.tw STEP 8: Set up Route for Data Transmission This SMS command set up the route that determine in which protocol the device ends up transmitting GPS
(GPRMC) positioning data. Please confirm the back-end server protocol type and corresponded URL or IP address with port number before setup. There are 3 main protocols available:
(Uniform Resource Locator). 1. HTTP: Hypertext Transfer Protocol. An internet browser based server protocol that usually has a specified URL 2. TCP/IP: TCP/IP provides end-to-end connectivity specifying how data should be packetized, addressed, transmitted, routed and received at the destination. 3. SMS: The device will send GPS data by SMS message format to Cellular phone that has been set in Phone U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. User can choose the route to transmit the data by HTTP/TCP/SMS protocol individually or with SMS message as a backup route. Please refer to the following table for the route setup. Setup Format: #<username>, <Password>, <Function Mode>, <0/2/4/6/7>*
Command: #username,0000,14,2* (HTTP Only)
#username,0000,14,7* (TCP Only) SMS/ COTA Command Description
Start sign. Username Default ID of the device. If you have changed the user name, please use the updated one. Default password. If you have changed the password, please use the updated one. Mode 14 defines Transmission Route mode. HTTP/SMS. Send data to HTTP server. If the route is not available, send data by SMS message instead. 2 HTTP only. Send data to HTTP server. No SMS backup route. 4 SMS only. Send data by SMS message to cell phone. No backup route. TCP/SMS. Send data to TCP server. If the route is not available, send data by SMS message instead. 7 TCP Only. Send data to TCP server. No SMS backup route. 0 6 End sign. Table: Data Transmission Route Setup Format Description Book. 0000 14 6
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 26 www.unictron.com www.sanav.com www.etek.com.tw U n i c t r o n T e c h n o o g e s C o r p
. l i A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. Situation Message Reply
[username] +, Device is switching to HTTP mode. Setup Succeeds
[username] +, Device TCP is updated.
[username] +, Device is switching to SMS mode. Table: Data Transmission Route Setup Response Description STEP 9: Set up Auto Report (Optional) Auto Report setup can enable the bracelet report GPS data automatically during a period of time. Use this command to set up the frequency of Auto Report. The bracelet can report according to interval. If you send the SMS command as the following example, it will send a report every 1 minute (60 seconds) and the total number of reports is 10. Setup Format#<User Name>, <Password>, <Function Mode>, <intervals (sec)>, <Number of Reports>*
Example#username 0000,6,60,9999*
Note1: Users may limit the number of the Auto reports by entering the digits from 1 to 9998 in the <Number of Reports>field. When you input 9999, the Auto Report Message will not stop unless you define a new Auto Report Setting. SMS Text Description
Start sign. username Default ID of Bracelet. 0000 Default password of Bracelet. If you have changed the Username, please use the updated one. If you have changed the password, please use the updated one. Mode 6 defines AUTO report setup mode. A constant interval of sending data (15~65000), default is 60. Unit : Second The number of reports will be sent automatically (0~9999), default is 9999 which means infinite. End sign. Table: Auto Report Setup Format Description 6 60 10
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 27 www.unictron.com www.sanav.com www.etek.com.tw Situation Message Reply Setup Succeeds
[username] + Setup OK. Device Auto Report setting is updated. Setup Fail
[username] + Auto Report setting Setup Fail!
Incorrect password
[username] + Password setup Fail!
Incorrect username or
[username] + command error command format Table: Auto Report Setup Response Description Step 10: Request IMEI Number IMEI stands for International Mobile Equipment Identification, a unique number for identifying mobile devices validity in GSM network. As above stated, each device has a unique IMEI number. Entering the SMS command as the following allows user to check the IMEI number of the device for network registration and tracking. U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. 0000 imei
Setup format: #<User Name>, <Password>, <Function Code>*
Command: #username,0000,imei*
SMS Text
Description Start sign. username Default user name of the device. If you have changed the username, please use the updated one. Default password. If you have changed the password, please use the updated one. Mode imei defines IMEI inquiry mode. End sign. Table: IMEI Inquiry Format Description Situation Response Setup Succeeds
[username] + ,[imei]
Incorrect password
[username] + Password setup Fail!
Incorrect username or
[username] + command error command format Table: IMEI Inquiry Response Description 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 28 www.unictron.com www.sanav.com www.etek.com.tw U n i c t r o n T e c h n o o g e s C o r p
. l i A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. Appendix 1: Report Data Format 1 2 357520074257524,
$GNRMC,081219.00,A,2457.80821,N,12125.53897,E,0.054,,160720,,,A*6C, 3 4 8 9 10 11 12 5
, 6
, 7
, AUTO, I0200, 9970, M16, 3782mV, 45, 2.40, 1 4 1, 466 24A5 13E16E
, 9, 13 15 16 17 18 19 20 21 22 23 24 25 26 27 36, FFFF, 45, 10613, 27, 14, FFFF, 29, 10613, 25, 10 Item Name Description 1 IMEI number IMEI stands for International Mobile Equipment Identification, a unique number for identifying mobile devices validity in GSM network. 1. 081219.00: time of fix (UTC) 2. A: GPS fix status, A = GPS fix, V = GPS no fix 3. 2457.80821,N,12125.53897,E,: Latitude/Longitude Coordinates 4. 0.054: Speed over ground, Knots 5.: Course over ground 6. 160720: Date of fix 16th,July, 2020 7. *6C: Mandatory checksum Triggered event or warning message. The ankle bracelets(HA) ID. Main GPRMC Sentence Event HA ID Reserved Reserved Reserved AUTO Report The accumulated number of AUTO report GSM sensitivity from M0 to M31. (M0~M31,the greater value is better. GSM Sensitivity M99 means not measurable) Battery Voltage Battery voltage indication GPS Sensitivity GPS signal strength. GPS HDOP Value The smaller value is the higher accuracy. GSM Cell ID MCC Mobile Country Code. The range is 0-999(1 to 3digits). 2 3 4 5 6 7 8 9 10 11 12 13 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 29 www.unictron.com www.sanav.com www.etek.com.tw U n i c t r o n T e c h n o o g e s C o r p
. l i A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. 14 GSM Cell ID MNC Mobile Network Code. The range is 0-999 (1 to 3digits). 15 GSM Cell ID LAC Location Area Code, The range is 0x0-0xFFFF (2 octets) Cell identity. The range is:
Cell identity. The range is:
16 GSM Cell ID o 2G cell: range 0x0-0xFFFF (2 octets) o 3G cell: range 0x0-0xFFFFFFF (28 bits) 16 GSM Cell ID o 2G cell: range 0x0-0xFFFF (2 octets) o 3G cell: range 0x0-0xFFFFFFF (28 bits) Received Signal Code Power expressed in dBm levels:
17 RSCP Level 0: less than -115 dBm 1..90: from -115 dBm to -26 dBm with 1 dBm steps 91: -25 dBm 18 Reserved FFFF 19 scrambling_code Scrambling code. The range is 0-511, 0 if not known or not detectable 20 dl_frequency Downlink frequency. The range is 0-16383. Received Signal Code Power expressed in dBm 21 rscp_lev 0: less than -115 dBm 1..90: from -115 dBm to -26 dBm with 1 dBm steps levels:
91: -25 dBm Energy per Chip/Noise ratio expressed in dB levels:
22 ecn0_lev 0: less than -24 dB 1..48: from -24 dB to 0.5 dB with 0.5 dB steps 49: 0 dB 23 Reserved FFFF 24 scrambling_code Scrambling code. The range is 0-511, 0 if not known or not detectable 25 dl_frequency Downlink frequency. The range is 0-16383. Received Signal Code Power expressed in dBm 26 rscp_lev levels:
0: less than -115 dBm 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 30 www.unictron.com www.sanav.com www.etek.com.tw 1..90: from -115 dBm to -26 dBm with 1 dBm steps 91: -25 dBm Energy per Chip/Noise ratio expressed in dB levels:
27 ecn0_lev 0: less than -24 dB 1..48: from -24 dB to 0.5 dB with 0.5 dB steps 49: 0 dB Appendix 2: Tracker Event List This table shows the different events/ messages sent from the device. Basically, there are more than 10 different situations that trigger the device to respond its position and tracker U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. status messages as the following. Event Description When the device is set to report to assigned route in a given period of time, it will send a report automatically with an AUTO message. AUTO When any other event such DT and ST message is triggered and the priority is greater than AUTO, the AUTO report will suspend. The AUTO report recovers until the Alarm-OFF command has been sent and the Alarm status ends. When the device has received the POLL command, the POLL message will be sent When the equipment fiber optic loop is opened (strap cut or broken), it triggers When the equipment reed switch is opened (the equipment case), it triggers the immediately. the ST event. DT event. the PLUG event. When the equipment is plugged in charger for more than 4 seconds, it triggers UNPLUG When the equipment is unplugged from charger, it triggers the UNPLUG event. CHOK When the equipment is unplugged from charger, the device will detect whether it When the equipment is fully charged, the CHOK message will be sent once. is fully charged. If so, the CHOK message will be sent once as well. When the equipment is unplugged from charger, the device will detect whether it is fully charged. If not, the CHFL message will be sent. When the equipment is in low power, it triggers the LP event. When the equipment is in the lowest power, it triggers the LP2 event and then shut down. POLL ST DT PLUG CHFL LP LP2 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 31 www.unictron.com www.sanav.com www.etek.com.tw U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. Note:
are cleared.
(1) Any event marks with letter B (Bauto..) represents data which was not able to send to assigned route immediately due to priority or mobile network service is not available. The data will be sent after the issues
(2) The event marks with letterL(LAUTO) represents power saving mode for data transmission.
"LAUTO" represents a specific number of AUTO reports. The equipment will send reports at once as a group when it has logged a fixed number of reports in the memory. SMS Command Introduction SMS Command setting 10. Any setup command must be started with a # sign and ended up with a * sign. Please note that all the characters which include #, * and comma (,) should be HALFWIDTH form. 11. Please be aware of the upper (capital)/lower cases when entering the SMS command. 12. While entering any SMS command, note that NO SPACE is allowed between the characters, comma and signs in the SMS. 13. The comma (,) can be abbreviated if no further setup required for the command besides Set up APN for GPRS Service. Please refer to the examples of Set up Auto Report. 14. The device will update setting only when the password, username and setup command are all correct. If the command is not valid, a failure report is going to be sent to the users cell phone. 15. If the device set up the authorized number, SMS commands should be sent via authorized number. 16. If the command is valid, a success report is going to be sent to the users cell phone. 17. Please make sure that the Call-Forward function of SIM card is turned off and Call-Display function of SIM card is turned on. 18. Please make sure that the PIN-Code of SIM card if off. If the PIN-Code is necessary, use 0000 as PIN-Code. 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 32 www.unictron.com www.sanav.com www.etek.com.tw How to Use ER Command for erase the flash This command is to erase the reports restored in the flash memory before. Once the GSM signal is weak or other reasons that cause that the device is not able to send reports to the server, the reports will be restored in the flash memory and re-sent later. In some case, you might want to erase those reports immediately, and then you can use this command. Please make sure that those reports in flash wont be needed anymore before you use it. Setup Format#<User Name>, <Password>, <Function Mode er>*
Example#username,0000,er*
Note: Erasing the flash memory takes about 90 seconds, so the reply will be a bit later than that of other SMS commands. In generally, the reply will be received in 2-3 minutes. U n i c t r o n T e c h n o o g e s C o r p
. l i A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. Description Start sign. Default ID of BRACELET. Default password. If you have changed the Username, please use the updated one. If you have changed the password, please use the updated one. Function code for erasing data in flash End sign. Table: ER Setup Format Description Situation Setup Succeeds Message Reply
[username] +, setup OK. Device logged data is erased. Table: ER Setup Response Description SMS Text
username 0000 er
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 33 www.unictron.com www.sanav.com www.etek.com.tw How to Restart The Device Use this SMS command to restart the device remotely. This command allow user to restart the device immediately or in schedule. Setup format: #<User Name>, <Password>, <Function Code>, <interval of restart>*
Command: #username,0000,rst,9*
Command: #username,0000,rst,now*
U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. SMS Text Description
Start sign. username Default user name of the device. If you have changed the username, please use the updated one. 0000 Default password. If you have changed the password, please use the updated one. rst Mode rst defines Restart the device. now or 1~9 Now means restarting the device immediately 1~9: Unit is 0.5 hour. 1 means 0.5 hour 9 means 4.5 hours (0.5 times 9 equals 4.5)
End sign. Table: Restart Format Description Situation Response Setup Succeeds
[username] + Setup OK. Device has been reset. Setup Fail
[username] + Reset Fail!
Incorrect password
[username] + Password setup Fail!
Incorrect username or command format
[username] + command error Table: Restart Response Description 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 34 www.unictron.com www.sanav.com www.etek.com.tw This setting defines the behavior when the device restarts. We can choose which opponent will be restarted such Setup format: #<User Name>, <Password>, <Function Code>, <Function Code>, <interval of restart>*
Setting of Restart The Device as MCU, GSM and GPS. Command: #username,0000,rst,cfg,7*
Command: #username,0000,rst,cfg,6*
SMS Text Description
Start sign. U n i c t r o n T e c h n o o g e s C o r p
. l i A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. username Default user name of the device. If you have changed the username, please use the updated one. 0000 Default password. If you have changed the password, please use the updated one. Mode rst defines Restart the device. Mode cfg defines Restart the device. 1: restart with MCU 2: restart with GSM 4: restart with GPS 6: restart with MCU and GSM 7: restart with MCU, GSM and GPS End sign. Table: Restart Setting Format Description rst cfg 6
Situation Response Setup Succeeds
[username] + Setup OK. Auto Reset is defined. Setup Fail
[username] + Reset Fail!
Incorrect password
[username] + Password setup Fail!
Incorrect username or command format
[username] + command error Table: Setting Restart Response Description 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 35 www.unictron.com www.sanav.com www.etek.com.tw U n i c t r o n T e c h n o o g e s C o r p
. l i A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. Use POll Command for acquiring the position This feature is for acquire the device position immediately. Once the device has received the POLL command, the POLL message will be sent to the server depending on the route youve set. The POLL message will be shown in the Event field of the report. Setup Format#<User Name>, <Password>, <Function Mode 10>*
Example#username,0000,10*
SMS Text Description Start sign. username Default ID of BRACELET. 0000 10
If you have changed the Username, please use the updated one. Default password. If you have changed the password, please use the updated one. Function code for polling End sign. Table: POLL Setup Format Description Situation Message Reply Setup Succeeds None Table: POLL Setup Response Description 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 36 www.unictron.com www.sanav.com www.etek.com.tw Set up FBR Command for Fiber Strap FRB feature is for detecting the strap violation. The default setting of FBR Tamper detected time is 10 seconds due to fiber characteristic. When the feature is turned on, if the strap is cut, the alarm will be triggered and the device will send the ST reports to indicate the strap violation. The ST state will be shown in the state field of report. The interval of ST report depends on the setting. There may be a buzzing sound or vibration if the buzzer and vibrator are turned on. Once the alarm is triggered, it will not stop only if the alarm off command is being sent. Regarding the alarm off command, please refer to the step 0 in the quick setting of SMS command. There are two types of command, the short one is for toggling the function quickly and the long one is for setting U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. Setup Format of short type#<User Name>, <Password>, <Function Mode fbr>, <0/1 (On/OFF)>*
Setup Format of long type#<User Name>, <Password>, <Function Mode fbr>, <0/1 (On/OFF)>, <Interval up all the parameter Example#username,0000,fbr,0*
Example#username,0000,fbr,1,60*
15~65000>*
SMS Text 0000 fbr 0/1 Description Start sign. Default password. Function code for fbr Toggle the function:
username Default ID of BRACELET. If you have changed the Username, please use the updated one. If you have changed the password, please use the updated one. 0 means the device will not detect the strap violation 1 means the feature is enabled. (default) 60 This parameter is for setting up the interval of ST report. The value range is from 15 to 65000. 60 means 60 seconds. (default) E.g. Once the fbr alarm is triggered , the device will send reports every 60 seconds until the alarm off command has been received.
End sign. Situation Setup Succeeds Table: FBR Setup Format Description Message Reply
[username] +, setup OK. Device Fiber detection is switched on/off. Table: FBR Setup Response Description 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 37 www.unictron.com www.sanav.com www.etek.com.tw SMS Text
username 0000 reed 0/1 Use REED Command for Cover Tamper FRB feature is for detecting the Tamper violation. When the feature is turned on, if the cover of the bracelet is opened, the alarm will be triggered immediately and the device will send the DT reports to indicate the strap violation. The DT state will be shown in the state field of report. The interval of DT report depends on the setting. There may be a buzzing sound or vibration if the buzzer and vibrator are turned on. Once the alarm is triggered, it will not stop only if the alarm off command is being sent. Regarding the alarm off command, please refer to the step 0 in the quick setting of SMS command. There are two types of command, the short one is for toggling the function quickly and the long one is for setting Setup Format of short type#<User Name>, <Password>, <Function Mode reed>, <0/1 (On/OFF)>*
Setup Format of long type#<User Name>, <Password>, <Function Mode reed>, <0/1 (On/OFF)>, <Interval up all the parameter Example#username,0000,reed,0*
15~65000>*
Example#username,0000,reed,1,60*
U n i c t r o n T e c h n o o g e s C o r p
. l i A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. Description Start sign. Default ID of BRACELET. Default password. Function code for reed Toggle the function:
If you have changed the Username, please use the updated one. If you have changed the password, please use the updated one. 0 means the device will not detect the strap violation 1 means the feature is enabled. (default) 60 This parameter is for setting up the interval of DT report. The value range is from 15 to 65000. 60 means 60 seconds. (default) E.g. Once the reed alarm is triggered , the device will send reports every 60 seconds until the alarm off command has been received.
End sign. Situation Setup Succeeds Table: REED Setup Format Description Message Reply
[username] +, setup OK. Device reed detection is switched on/off. Table: REED Setup Response Description 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 38 www.unictron.com www.sanav.com www.etek.com.tw Command for Toggling the Buzzer and vibrator When the Alarm events (such as ST, DT, Geo-fence event) are triggered, the device will beep and vibrate for notice as well as send the reports. This command is to toggling the beep sound and vibration respectively and configuring the interval of notice. This command only affects the beep sound and vibration when the Alarm events are triggered. There are two types of command, the short one is for toggling the function quickly and the long one is for setting Setup Format of short type#<User Name>, <Password>, <Function Mode 19>, <0/1 (Buzzer On/OFF)> , up all the parameter
<0/1 (Vibration On/OFF)>*
Example#username,0000,19,0,0*
Setup Format of long type#<User Name>, <Password>, <Function Mode 19>, <0/1 (Buzzer On/OFF)> , <0/1
(Vibration On/OFF)>, <1 (Interval of beep sound)> , <180 (Interval of vibration)>*
Example#username,0000,19,1,1,1,180*
U n i c t r o n T e c h n o o g e s C o r p
. l i A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. Description Start sign. Default ID of BRACELET. Default password. If you have changed the Username, please use the updated one. If you have changed the password, please use the updated one. Function code for toggling the beep sound and vibration Toggle the beep sound:
0: turn off the beep sound during the Alarm event. 1: turn on the beep sound during the Alarm event. (default) 0/1 Toggle the vibration:
0: turn off the vibration during the Alarm event. 1: turn on the vibration during the Alarm event. (default) This parameter is for setting up the interval of beep sound. The value range is from 0.2 to 65000. 1 means 1 second. (default) E.g. Once the alarm event is triggered, the device will beep every 1 second until the alarm off command has been received. 180 This parameter is for setting up the interval of vibration. The value range is from 1 to 65000. 1 means 1 second. (The default setting is 180) E.g. Once the alarm event is triggered, the device will vibrate every 180 seconds until the alarm off command has been received. End sign. Table: Toggle Beep & Vibration Setup Format Description SMS Text
username 0000 19 0/1 1
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 39 www.unictron.com www.sanav.com www.etek.com.tw Situation Buzzer setup succeed Message Reply
[username] +, setup OK. Device buzzer is turned off. / on. Vibrator setup succeed
[username] +, vibration motor is disabled. / enabled. Buzzer and Vibrator setup scceed
[username] +, setup OK. Buzzer & vibrator setting are updated. Buzzer or Vibrator setup fail
[username] +, buzzer or vibrator switch setup fail!
Parameter setup fail
[username] +, setup fail! buzzer or vibrator parameter error!
Table: Toggle Beep & Vibration Setup Response Description U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 40 www.unictron.com www.sanav.com www.etek.com.tw Power Saving Mode Setup This mode has two part of feature. In Power Saving Mode 0, the battery life can be saved by stopping GPS output temporarily while the device isnt reporting. This is the default setting. Set <Power Saving Mode> to 0 to enable it such like this command: #username,0000,combo,0*. In Power Saving Mode 1, power save mode will be disabled and the GPS is always on. If the GPS signals are often poor in your environment, to use this mode is recommended. Set <Power Saving Mode> to 1 to disable it such like this command: #username,0000,combo,1*. Setup Format: #<User Name>, <Password>, <Function Mode>, <Power Saving Mode>*
Command: #username,0000,combo,3*
U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. SMS Text Description
username Start sign. Default user name of the device. If you have changed the username, please use the updated one. 0000 Default password. combo Mode combo defines Power Save mode If you have changed the password, please use the updated one. 0 Power Saving mode 0. The basic power save interval is 30 seconds. The device will try to get valid position data every 30 seconds and the interval will be accumulated (30, 60, 90, 120etc) if successful (well positioned), or start from 30 sec. interval. End sign. 1 To disable the Power Saving mode. GPS will always on. Table: Power Save Mode Setup Format Description Situation Description Success
[username] +, Device Combo mode has been deactivated. Table: Power Save Mode Setup Response Description 1
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 41 www.unictron.com www.sanav.com www.etek.com.tw U n i c t r o n T e c h n o o g e s C o r p
. l i A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. AES128 encryption function setting Set <Encryption Mode> to 1 to enable it such like this command: #username,0000,aes,1*. Setup Format: #<User Name>, <Password>, <Function Code>, <Encryption Mode>*
Command: #username,0000,aes,1*
SMS Text Description
username Start sign. Default user name of the device. If you have changed the username, please use the updated one. Default password. If you have changed the password, please use the updated one. Code AES defines encryption function. 0 Disable returned data encryption by AES128 function. End sign. Table: AES128 encryption Setup Format Description Encryption Mode 1 Enable returned data encryption by AES128 function. Situation Description
[username] + setup OK. Device data for aes128 protection is switched off. / on.
[username] + , command error. Table: AES128 encryption Setup Response Description 0000 AES
Success fail 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 42 www.unictron.com www.sanav.com www.etek.com.tw U n i c t r o n T e c h n o o g e s C o r p
. l i A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. TCP acknowledge function setting Set <Function Mode> to 1 to enable it such like this command: #username,0000,tcpack,1*. Setup Format: #<User Name>, <Password>, <Function Code>, <Function Mode>*
Command: #username,0000,tcpack,1*
SMS Text Description
username Start sign. Default user name of the device. If you have changed the username, please use the updated one. 0000 Default password. If you have changed the password, please use the updated one. TCPACK Code TCPACK defines acknowledge function. Function Mode 1 Enable returned data acknowledge function. 0 Disable returned data acknowledge function. End sign. Table: TCP acknowledge Setup Format Description Situation Description Success fail
[username] + setup OK. Device tcp ack mode is updated.
[username] + , command error. Table: TCP acknowledge Setup Response Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 43 www.unictron.com www.sanav.com www.etek.com.tw Set up Low Power reminder The user can set the SMS/COTA command to alert user if the battery voltage is low or automatically shut down system when the battery voltage reaches a certain threshold. Setup Format: #<User Name>, <Password>,<Function Code>, <Voltage Value 1>,< Voltage Value 2>*
Command: #UserName,0000,LP,3650,50*
SMS/ COTA Command Description
Start sign. U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. UserName Default ID of the device. If you have changed the user name, please use the updated one. 0000 Default password. Function Code Code LP defines the Low Power alarm setting. If you have changed the password, please use the updated one. Voltage Value 1 (V1) The range is 3500~3800, when the voltage reaches this value, the LP event will Voltage Value 2 (V2) The range is 1~99, when the voltage is lower than V1 - V2, LP2 event will be sent be sent out out and shut down
End sign. Table: Low Power Setup Description Situation Message Reply Setup Succeed Setup fail
[username] + setup OK. Device low power value setting is updated.
[username] + Setup fail. Device low power value setting is not change. Table: Low Power Setup Response Description 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 44 www.unictron.com www.sanav.com www.etek.com.tw U n i c t r o n T e c h n o o g e s C o r p
. i l A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. GSM Cell Information Setting Use this command to switch the display GSM Cell Information in the data of report. Setup Format: #<User Name>, <Password>,<Function Code>, <Mode>*
Command: # UserName,0000,cellid,1*
SMS/ COTA Command Description Start sign. UserName Default ID of the device. If you have changed the user name, please use the updated one. 0000 Default password. If you have changed the password, please use the updated one. Function Code Mode cellid defines the Cell ID information Setting setup mode. Mode 0: Disable cell information report function. 1: Enable 3 groups of cellid and all parameters.
End sign. Table: Cell ID Setting Setup Format Description Situation Message Reply Setup Succeed Setup fail
[username] + , setup OK. GSM Cell ID Function is turned off.
[username] + , command error. Table: Cell ID Setting Setup Response Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 45 www.unictron.com www.sanav.com www.etek.com.tw U n i c t r o n T e c h n o o g e s C o r p
. l i A l l s p e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e
. Firmware upgrade Over The Air (FOTA) function Use this command to upgrade firmware from a file on http server. Setup Format: #<User Name>, <Password>,<Function Code>, <URL of firmware>*
Command: #
UserName,0000,fota,Http://220.128.123.1:8000/NB5-F5359-0609201617-VA1.0.3-OTA(00383390).txt*
SMS/ COTA Command Description
Start sign. UserName Default ID of the device. If you have changed the user name, please use the updated one. 0000 Default password. If you have changed the password, please use the updated one. Function Code Code fota defines the firmware upgrade function. URL of firmware URL of firmware file on http server, file name could be any, but need add a OTA(filesize) at file name tail, filesize must be 8 digit with 0 prefix.
End sign. Table: FOTA command Format Description Situation Message Reply command Succeed Upgrade completed
[username] + , Device OTA Process Start.
[username] + , Download success. Device will start update and reboot.
[username] + , Server Return File Not Found, or file size not matching. Or Or Upgrade fail
[username] + , Download fail. Receive data not complete.
[username] +, erase flash fail. OTA is canceled. command fail
[username] + , command error. Table: FOTA command Response Description 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456Fax: 886-2-22694451service@unictron.com 46 www.unictron.com www.sanav.com FCC Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction. Specific Absorption Rate (SAR) information:
This NB5 meets the government's requirements for exposure to radio waves. The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety of all persons regardless of age or health. FCC RF Exposure Information and Statement the SAR limit of USA (FCC) is 1.6 W/kg averaged over one gram of tissue. Device types: Tablet has also been tested against this SAR limit. This device was tested for typical body-worn operations with the back of the phone kept 10mm from the body. To maintain compliance with FCC RF exposure requirements, use accessories that maintain an 10mm separation distance between the user's body and the back of the phone. The use of belt clips, holsters and similar accessories should not contain metallic components in its assembly. The use of accessories that do not satisfy these requirements may not comply with FCC RF exposure requirements, and should be avoided. Consult the dealer or an experienced radio/TV technician for help.
1 2 | Label and location | ID Label/Location Info | 68.53 KiB | April 16 2021 |
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AY5H-OT101 Label and Location NB5 Model No: NB5 FCC ID: 2AY5H-OT101 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Size: L: 3cm*W: 3cm Label Location This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 1
1 2 | Agent Authorization Rev 1.0 | Cover Letter(s) | 15.41 KiB | April 16 2021 |
Unictron Technologies Corp. Agent Authorization Company: Unictron Technologies Corp. Address: 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist.,New Taipei City 236, Taiwan (R.O.C.) Product Name: NB5 Trade Mark: N/A Model Number(s): NB5, CT-31, NB-5 FCC ID: 2AY5H-OT101 We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature:
Name:
Julian Liang Title:
senior manager Company: Unictron Technologies Corp. Date: 2021-04-09
1 2 | Declaration Letter of Model Difference | Cover Letter(s) | 13.55 KiB | April 16 2021 |
Unictron Technologies Corp. 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist.,New Taipei City 236, Taiwan (R.O.C.) Tel: (886-2)2269-4456#722 E-mail: julian.liang@unictron.com Series Models Description Date: 2021/04/09 To: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA FCC ID: 2AY5H-OT101 Dear Sir/Madam, We, Unictron Technologies Corp. Hereby declares the following statement for Federal Communications Commission, PCB board, circuit, structure and internal of these model(s) are the same, Only color and model number is different for these model:
Product name:
Model no.:
NB5 NB5, CT-31, NB-5 Sincerely, Phone:
E-Mail:
Name:
Julian Liang / senior manager Company: Unictron Technologies Corp. Address:
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist.,New Taipei City 236, Taiwan
(R.O.C.)
(886-2)2269-4456#722 julian.liang@unictron.com
1 2 | FCC Short & Long Term Confidentiality | Cover Letter(s) | 65.84 KiB | April 16 2021 |
Unictron Technologies Corp. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2021-04-09 Subject; Request for Confidentiality FCC ID: 2AY5H-OT101 To Whom It May Concern, Pursuant to the provisions of the Commissions rules Title 47 Sections 0.457 and 0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure External Photos Test Setup Photos Internal Photos User Manual In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR 2.803 and the importation rules in Title 47 CFR 2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s);
OR For 45 days, pursuant to Public Notice DA 04-1705. For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature:
Name: Julian Liang Title: senior manager
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2021-04-16 | 1852.4 ~ 1907.6 | PCB - PCS Licensed Transmitter | Original Equipment |
2 | 436.8 ~ 436.8 | DSC - Part 15 Security/Remote Control Transmitter |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 | Effective |
2021-04-16
|
||||
1 2 | Applicant's complete, legal business name |
Unictron Technologies Corp.
|
||||
1 2 | FCC Registration Number (FRN) |
0030666705
|
||||
1 2 | Physical Address |
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist.
|
||||
1 2 |
New Taipei City, N/A 236
|
|||||
1 2 |
Taiwan
|
|||||
app s | TCB Information | |||||
1 2 | TCB Application Email Address |
c******@micomlabs.com
|
||||
1 2 | TCB Scope |
B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
|
||||
1 2 |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
|||||
app s | FCC ID | |||||
1 2 | Grantee Code |
2AY5H
|
||||
1 2 | Equipment Product Code |
OT101
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 | Name |
J**** L******
|
||||
1 2 | Title |
senior manager
|
||||
1 2 | Telephone Number |
(886-********
|
||||
1 2 | Fax Number |
(886-********
|
||||
1 2 |
j******@unictron.com
|
|||||
app s | Technical Contact | |||||
1 2 | Firm Name |
Unictron Technologies Corp.
|
||||
1 2 | Physical Address |
Taiwan
|
||||
1 2 |
j******@unictron.com
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 2 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 | Equipment Class | PCB - PCS Licensed Transmitter | ||||
1 2 | DSC - Part 15 Security/Remote Control Transmitter | |||||
1 2 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | NB5 | ||||
1 2 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 | Modular Equipment Type | Does not apply | ||||
1 2 | Purpose / Application is for | Original Equipment | ||||
1 2 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | Yes | ||||
1 2 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 | Grant Comments | Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for front of face use condition is 0.21W/kg. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations. | ||||
1 2 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 | Firm Name |
Shenzhen LCS Compliance Testing Laboratory Ltd.
|
||||
1 2 | Name |
G**** L****
|
||||
1 2 | Telephone Number |
0755-********
|
||||
1 2 | Fax Number |
0755-********
|
||||
1 2 |
g******@lcs-cert.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 22H | 824.2 | 848.8 | 0.9162 | 0.029 ppm | 244KGXW | ||||||||||||||||||||||||||||||||||
1 | 2 | 22H | 824.2 | 848.8 | 0.2972 | 0.053 ppm | 253KG7W | ||||||||||||||||||||||||||||||||||
1 | 3 | 24E | 1850.2 | 1909.8 | 0.6237 | 0.024 ppm | 245KGXW | ||||||||||||||||||||||||||||||||||
1 | 4 | 24E | 1850.2 | 1909.8 | 0.1959 | 0.018 ppm | 249KG7W | ||||||||||||||||||||||||||||||||||
1 | 5 | 22H | 826.4 | 846.6 | 0.1117 | 0.008 ppm | 4M16F9W | ||||||||||||||||||||||||||||||||||
1 | 6 | 24E | 1852.4 | 1907.6 | 0.139 | 0.024 ppm | 4M18F9W | ||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 15.231 | 436.80000000 | 436.80000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC