AC-2100 Plus. USER GUIDE Version ENG-1.00 Copyright 2000 By Union Community Co., LTD. AC-2100 Plus 2
<Revison History>
Version Date Description 1.00 2016-12-28
-Initial Release Firmware Version 10.61.00-000.00 UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 3
<Glossaries>
Administrator (Admin)
- The administrator can access to the terminal menu mode. He/she has the authority to add/modify/delete terminal users and to change the operating environment by changing settings.
- If there is no registered administrator in the terminal, anybody can access to the terminal menu and change settings. It is recommended that more than one administrator will be necessarily registered in the terminal.
- The administrator has the authority to change critical environmental settings of the fingerprint reader. So, special attention is required to its registration and operation. 1:1 Authentication (One-to-one, Verification)
- The user fingerprint is verified after entering User ID or Card.
- Only User ID or the user fingerprint registered to the card is compared. This is called One-to-
One Authentication. 1:N Authentication (One-to-many, Identification)
- The user is identified only by the fingerprint.
- The same fingerprint as the input fingerprint is identified among the registered fingerprints without User ID or Card entered. This is called One-to-N Identification. Authentication Level
- As a level used for fingerprint authentication, it is displayed in Step 1 to 9. Authentication cannot be allowed before the degree of match between two fingerprints is higher than the set authorization level.
- The higher authentication level may ensure the higher security. But it requires the relatively high concordance rate. So it high likely to deny authentication when trying to authenticate.
- 1:1 Level: Authentication level used for One-to-one authentication
- 1:N Level: Authentication level used for One-to-N authentication Authentication Method
- This refers to various types of authentication methods composed of each combination of FP(Fingerprint) and RF(Card) and so forth. Ex) Card or FP: Authenticated by either card or fingerprint Function Key
- This refers to [F1], [F2], [F3], and [F4] keys, which enable users to access the menu or change the mode such as Attend or Leave. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 4 Table of Contents
<Revison History> .................................................................................................... 2
<Glossaries> ............................................................................................................... 3 Table of Contents ........................................................................................................ 4 1. Before Getting Started ............................................................................................. 6 1.1. Safety Notes .................................................................................................... 6 1.2. Product Details ............................................................................................... 7 1.3. Buttons displayed during operation ................................................................. 8 1.4. ViRDI logo LED signals displayed during operation ........................................ 8 1.5. Screens displayed during operation ................................................................. 8 1.5.1. Icon Information ...................................................................................... 9 1.5.2. Message Information ................................................................................ 9 1.6. Voice guide announced during operation ....................................................... 13 1.7. Buzzer guide announced during operation ..................................................... 13 1.8. How to register and enter correct fingerprint ................................................ 13 2. Product Description ............................................................................................... 15 2.1. Product Features........................................................................................... 15 2.2. Configuration Diagram ................................................................................. 17 2.2.1. Standalone Use (Access) ......................................................................... 17 2.2.2. Connecting the PC server (Access, T&A, Food Service Control) ................ 17 2.3. Product Specification .................................................................................... 18 3. Environment Setting .............................................................................................. 19 3.1. Checkpoints before environment setting ........................................................ 19 3.1.1. Enter the menu ...................................................................................... 19 3.1.2. Modify settings ...................................................................................... 20 3.1.3. Save after completion of environment setting ............................................ 20 3.2. Menu Configuration ..................................................................................... 21 3.3. User Management ......................................................................................... 25 3.3.1. Add User ............................................................................................... 25 3.3.2. Delete User ........................................................................................... 28 3.3.3. Modify User .......................................................................................... 29 3.3.4. Add Administrator .................................................................................. 32 3.3.5. Delete All Users ..................................................................................... 32 3.4. Network Setting ............................................................................................ 33 3.4.1. Terminal ID ........................................................................................... 33 3.4.2. IP Setting .............................................................................................. 35 3.4.3. Server IP Setting .................................................................................... 36 3.5. Option Setting ............................................................................................... 40 3.5.1. Application Setting ................................................................................. 40 3.5.2. Authentication Method Setting ................................................................ 45 3.5.3. Door Setting .......................................................................................... 49 3.5.4. Volume Setting ...................................................................................... 50 3.5.6. Current Time Setting .............................................................................. 51 3.5.7. RS485 Set ............................................................................................. 53 3.6. Terminal Information Inquiry ....................................................................... 54 3.7. Additional Function (Extra Function) ............................................................ 55 3.7.1. Terminal Lock Setting ............................................................................ 56 UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 5 3.7.2. Card Number Inquiry ............................................................................. 56 3.7.3. Monitor Input Port Setting ...................................................................... 57 3.7.4. Duress FP Setting ................................................................................... 58 3.8. Device Setting ............................................................................................... 59 3.8.1. System Configuration ............................................................................. 59 3.8.2. Card Reader Format Setting .................................................................... 60 3.8.3. Fingerprint Sensor Setting ....................................................................... 60 3.8.4. Wiegand Speaker Output ........................................................................ 62 3.8.5. Terminal Initialization ............................................................................ 64 3.8.6. External Device Setting .......................................................................... 66 4. How to Use Terminal ............................................................................................. 69 4.1. When operating to [1.Access] ........................................................................ 69 4.1.1. Authentication Mode .............................................................................. 69 4.1.2. Authentication Using Fingerprint ............................................................. 69 4.1.3. Authentication Using Card ...................................................................... 70 4.2. When operating to [2.T&A] .......................................................................... 72 4.2.1. Authentication Mode .............................................................................. 72 4.2.2. Fingerprint Authentication ...................................................................... 72 4.2.3. Authentication Using Card ...................................................................... 72 4.3. When operating to [2.Cafeteria] .................................................................... 72 UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 6 1. Before Getting Started 1.1. Safety Notes Warning Do not operate the terminal with wet hands, and pay attention not to let any liquid such as water enter inside the terminal. Otherwise, malfunction or electric shock may be caused. Do not disassemble, repair or remodel the terminal at your disposal. Otherwise, it may cause malfunction, electric shock, or a fire. Keep the terminal away from inflammables. Otherwise, it may cause a fire. Do not allow children to touch the terminal carelessly. Otherwise, it may cause safety accidents of children or malfunction.
- Non-compliance of safety notes may cause death or serious injury for users. Cautions Do not install the terminal in a place exposed to direct sunlight. Otherwise, it may cause malfunction, deformation and discoloration. Do not clean this terminal by sprinkling water, nor wipe it with benzene, thinner, and alcohol. Otherwise, it may cause electric shock or a fire. Keep the fingerprint input section clean. Otherwise, the fingerprint cannot be recognized correctly. Keep the terminal away from shock or sharp objects. Otherwise, it may damage the terminal and result in malfunction. Do not install the terminal in humid or dusty places. Otherwise, it may cause malfunction. Keep the terminal away from magnets. Otherwise, it may cause failure and malfunction. Do not spray insecticides or inflammables on the terminal. Otherwise, it may cause deformation and discoloration. Do not install the terminal in a place where there is a severe change in temperature. Otherwise, it may cause malfunction.
- Non-compliance of safety notes may cause personal injury or property damage for users. We are not responsible for any accidents and damage that may arise from non-compliance of the information in this manual. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 7 1.2. Product Details Status LED 1.77inch TFT LCD
(128*160) Touch Key FP Sensor Smart Card UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 8 1.3. Buttons displayed during operation F1 F2 F3
- Switch to Attend mode from the default screen.
- Used to move up or increase [] in the menu mode
- Switch to Leave mode from the default screen.
- Used to move down or decrease [] in the menu mode.
- Switch to Outdoor mode from the default screen.
- When pressing for more than 2 seconds, you enter the menu mode:
[F3~]
- Used to escape [ESC] or move left [] in the menu mode. When pressing for more than two seconds, this is used to [ESC] button:
[ESC~]
- Switch to Return mode from the default screen. Pressing it again in the Return mode is changed to Access mode. F4
- Used to enter [ENT] or move right [] in the menu mode. When pressing for more than two seconds, this is used to [ENT] button:
[F4~]
1.4. ViRDI logo LED signals displayed during operation ViRDI Power Blue On: Normal Flickering: Under Bluetooth communication ViRDI Door Green On: Door Open Off: Door Close ViRDI Alarm Red Off: Normal Flickering: Case Open or Lock Controller Communication Error The LED may light on simultaneously in some cases. (Ex. Red and Blue flicker) 1.5. Screens displayed during operation Displays the current time
- When access control: Displays access mode (F1, F2, F3, F4, Access)
- When T&A control: Displays Attend/Leave mode (Attend, Leave, Outdoor, Return)
- When food service control: Displays the menu and current meal time countdown Displays Status icon and Access mode UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 9 1.5.1. Icon Information Fire Detection A fire is detected by the fire detection sensor. Door Status Server Connection Status USB Connection 1.5.2. Message Information Doors open state (forced open door or open the door when leaving). The LAN cable is not connected. Only Link is connected. The USB is connected.
- The default screen of AC2100
- The fingerprint is being input or on standby.
- When authentication is successful UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 10
- When authentication fails
- When fingerprint input fails
-
If your finger is released too early before your fingerprint is entered
- When an unregistered card is swiped
- When 1:N Authentication is attempted under the condition that authentication priority is SN and there is no user who has been allowed for 1:N Authentication
- When anti-passback is in error
- When the server cannot handle too many authentication requests from the terminal UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 11
- When the terminal is set to the food service control and users attempt more than two times authentication in the same food time zone
- When there is no response from the server during authentication attempt
- When the network is disconnected during authentication attempt to the server
- The card input is on standby.
- When the card is registered but its authentication is not attempted in the access control time
- When the terminal waits for a response after requesting authentication to the server, UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 12
- When the terminal is locked
- When the food service control is set in the non-meal time
- When the terminal program is upgraded
(Do not power off the terminal when this message is displayed.) UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 13 1.6. Voice guide announced during operation Item Voice Guide When the fingerprint is entered Please enter your fingerprint. When authentication is successful You are authorized. When authentication fails Please try again. 1.7. Buzzer guide announced during operation Ppik When button or card is operated
- If the button is pressed or if the terminal reads the card
- If your finger may be released because your fingerprint has been successfully entered Ppibik When failure If authentication fails or the users input is wrong Ppiriririk When input standby When it is notified that fingerprint input is on standby Ppiririk When success If authentication is successful or if the current user finishes settings 1.8. How to register and enter correct fingerprint Correct fingerprint input method Enter your fingerprint as if you take a thumbprint by using your forefinger if possible. The fingerprint cannot be correctly registered and entered only by your fingertips. The center of the fingerprint should be touched with the fingerprint input section. Enter the fingerprint of your forefinger if possible. When using your forefinger, you can enter your fingerprint correctly and safely. Make sure that the fingerprint is unclear or wounded. Too dry, wet, blurry or wounded fingerprints are difficult to recognize. In this case, the fingerprint of another finger should be registered. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 14 Precautions subject to your fingerprint status The availability of the fingerprint may vary subject to your fingerprint status. This product consists of a fingerprint recognition system and cannot recognize the damaged or unclear fingerprints. They should be registered using a password. If your hands are dry, you can blow your breath on the system to operate it more smoothly. For children, too small or unclear fingerprints may be difficult or impossible to use. They need to register a new fingerprint every six months. For seniors, the fingerprint with too many lines may not be registered. It is recommended that you will register more than two fingerprints if possible. In order to increase the fingerprint authentication rate, it is recommended to use six of the ten fingers as illustrated above. (Both thumbs, forefingers, middle fingers) UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 15 2. Product Description 2.1. Product Features Access control system using the network (LAN)
- The fingerprint reader communicates with the authentication server using a UTP cable and TCP/IP protocol. This terminal can be applied to the existing LAN network and has easy expandability. It ensures a fast speed by 10/100 Mbps Auto Detect and facilitates management and monitoring via the network. Convenient Auto Sensing function
- The authentication function can be simply operated by entering the fingerprint without separate keys entered. Easy to verify your ID via fingerprint
- The use of the fingerprint recognition technology (Biometrics) can prevent forgetting your password, losing your card or key, or avoid the risk of their theft. The use of personal fingerprints enhances the security of authentication. Convenient information message using LCD and voice
- The information message is voiced or displayed on the LCD display for each operation to receive certification so that you can easily input. In particular, thanks to a built-in backlight for the LCD display, you can easily identify the screen and operate keys in the dark room. The voice is stored in the memory and it can be changed to a desired voice from the server. Diverse and flexible access control function
- Easy to use it without the risk of rental, counterfeit and loss of your key or card;
- Provide the complete access control function by granting access authority according to user groups;
- Provide the flexibility of access control by allowing the access time restrictedly;
- Economical maintenance and development costs compared to other access control devices;
- Remove the inconvenience that visitors are registered in the management office and then separate cards are issued. Diverse utilization for operating systems such as security, access, T&A, and food service
- Various operating methods can be supported depending on how the terminal menu is set. Large processing capacity of server
- When the entrant information is managed using the server, it can be processed almost infinitely. Provide the Printer Interlock function
- Provide the output function for the authentication information through the printer at every time you authenticate. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 16 Various registration and authentication methods There are a total of four registration and authentication methods for general users. Before registering users or administrators, you should determine how to register and authenticate. FP Card Card or FP Card and FP Fingerprint Registration Fingerprint Authentication Card Registration Card Authentication Card or Fingerprint Registration Card or Fingerprint Registration Card and Fingerprint Registration Card Authentication and then Fingerprint Authentication UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 17 2.2. Configuration Diagram 2.2.1. Standalone Use (Access) DC12V Adapter
(Lock+, Lock-, Monitor) 2.2.2. Connecting the PC server (Access, T&A, Food Service Control) TCP/IP Internet /
WAN / LAN TCP/IP TCP/IP TCP/IP TCP/IP TCP/IP Fingerprint Authentication Server (Static IP) UDB Sever Database (MDB or MSSQL) Remote Administrator Program
(User and Terminal Setting Management) Food Service Control Program Attendance Control Program UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 18 2.3. Product Specification CPU MEMORY SPEC REMARK 32 bits RISC CPU(400MHz) 64M SDRAM 32M NOR FLASH 128M NAND FLASH 1,500 User 1,500 Finger 10,000 Log Fingerprint Sensor Optical Authentication Speed Less than 1 second Scan Area / Resolution 12.6 * 14.8mm / 500 DPI FRR / FAR 0.1% / 0.0001%
Communication Port Temperature /
Humidity LCD SIZE AC / DC Adapter TCP/IP RS-232 RS-485 Wiegand In/Out
-20 ~ 60 /
Lower than 90% RH 1.77 Color LCD 58mm(W) * 191mm(H) * 62mm(D) INPUT : Universal AC 100 ~ 250V OUTPUT : DC 12V
(Option : DC 24V) UL, CSA, CE Approved Authentication Server Communication Printer External Device Communication Card Reader or External Device Communication Card Reader Smart Card Reader 14443A type, 13.56MHz UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 19 3. Environment Setting 3.1. Checkpoints before environment setting 3.1.1. Enter the menu When pressing [F3] button for more than 2 seconds, the administrator authentication screen will be displayed. The administrator is verified by either card or fingerprint depending on the authentication method. Upon successful authentication, the screen goes to the following menu. Select the menu you want to change using
[](F1) and [](F2) buttons, and press [ENT]
(F4) button to go to the submenu. The description of function buttons such as F1, F2, F3, and F4 is in numerical order on the bottom of the screen as shown above. Go up and down the screen, you can press [ENT](F4) button to select the desired menu, or press [ESC] (F3) for more than 2 seconds to return to the upper menu. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 20 The administrator authentication menus is displayed only when there is any registered administrator. Once it is authenticated to enter the menu mode, you can access to all menus until you escape completely from the main menu. 3.1.2. Modify settings Modify the existing settings by pressing [][] buttons. If the set value is greater than or equal to 2 digits, press [][] buttons to move to the digit you want to change, and press [][] buttons to change the value up or down. Press [ENT] button to check the set value or go to next setting. If you want to cancel during the setting and move to the upper menu, press [ESC] button for more than 2 seconds. If only [][][][] buttons are displayed except [ESC] and [ENT] buttons, [ESC] is enabled by pressing [F3] for more than 2 seconds, and [ENT] by pressing [F4] for more than 2 seconds. 3.1.3. Save after completion of environment setting After changing settings, press [ESC] button on the main menu screen to save the changes, and the following screen will be displayed. Select [Yes] button to save modifications, [No]
button to cancel modifications, and then press
[ENT] button. If there is any modified information, the terminal will be rebooted. If there is no change information, the screen exits from the environment setting menu without the Save? process. If no data is input in the main menu for a certain time during changing environment setting, the screen will exit from the environment setting menu. In this case, if there is any change in the menu, the screen performs the Save? process. If there is no change in the menu, the screen goes to the main screen without saving changes. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 21 3.2. Menu Configuration 1. User 1. Add User 2. Delete 3. Modify 4. Add admin 5. Delete All 2. Network 1. Terminal ID
<Terminal ID>
<Auth Mode>:NS/SN/NO/SO 2. Terminal Net 3. Server Net 3. Option 1. Application
<Net Type>
<Terminal IP>
<Subnet Mask>
<Gateway>
<Server Type>
<Server IP>
<Server Port>
<WorkMode>
1. Access 2. T&A 3. Cafeteria When setting to Access
<F1 Time>
<F2 Time>
<F3 Time>
<F4 Time>
<Access Time>
<Multi Fn-Key>
<Use Printer>
When setting to T&A
< Attend>
<Leave >
< Out>
< In>
<Access Time>
<Multi Fn-Key>
<Use Printer>
When setting to Cafeteria
<Breakfast>
<Lunch>
<Dinner>
<Supper>
<Snack>
<No Limit>
<Use Printer>
UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 22 2. Verify 3. Doorlock 4. Sound 5. Time
<Show User>
<Only Card>
<Use TOC>
<Blocking Time>
<Global Block>
<NetErr TimeOut>
<Open Duration>
<Open Alarm>
<Voice>
<Beep>
<Case Open>
<Sync Time>
<Calendar>
<System Time>
<Time Display>
6. RS485 Set
<RS485 ID>
UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 23 4. Terminal Info Firmware version of the terminal Terminal operating modes (T&A +
security/T&A/food service) Language setting Authentication priority Authentication level applied when 1:1 authentication Authentication level applied when 1:N authentication Terminal ID Network connection methods (Static IP/DHCP) Terminal IP address Terminal gateway address Terminal subnet mask address Network server connection mode setting IP address of the network server connected to the terminal Port number of the network server program Terminal MAC address Card reader module firmware version Card data display format The total number of users registered in the terminal, including administrators The number of administrators registered in the terminal The maximum number of users who can be registered in the terminal The total number of fingerprints saved in the terminal The maximum number of fingerprints that can be registered in the terminal The number of the authentication results saved in the terminal The maximum number of the authentication results that can be saved in the terminal Serial number notation Version WorkMode Language Auth Mode 1:1 Level 1:N Level Terminal Id Net Type Terminal IP Gateway Subnet Mask Server Type Server IP Server Port MAC Address Card Ver Card Format All User All Admin Max User All FP Max FP All Log Max Log Serial Num UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 24 5. Ext Function 1. Lock Term
<Lock Term>
2. Read Card
<Read Card>
3. Monitor
<Monitor 1>
<Monitor 2>
4. Duress FP
<Duress FP>
6. Device 1. Sys Config 2. Card Format 3. FP-Sensor 4. Wiegand 5. Initialize 6.Ext Device
<ID Length>
<Language>
<Card Reader>
<Card Format>
<1:1 Level>
<1:n Level>
<LFD Level>
<Check FP>
<Wiegand Out>
<Init Config>
<Delete Log>
<Init Terminal>
<DB Backup>
<External Device>
<Local AntiPB>
<Auth Mode>
<Lock Ctrl>
UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 25 3.3. User Management Select [1.User] on the main menu, and the following screen will appear. Press [][] buttons to select the menu you want to change, and press [ENT] button. 3.3.1. Add User Select [F3~][1.User][1.Add User] on the main screen, and the following screen will appear. Enter the ID of the new user you wish to register, and press [F4] button long. When registering, the available user ID is automatically displayed on the LCD so that you can register it conveniently. If necessary, you can change the ID using function keys. If other user has been already registered in the entered ID, the message of Duplicated User ID with Fail buzzer is displayed on the LCD and then the screen goes to the upper menu. If the entered ID is not registered, the following authentication type selection screen appears. By using [][] buttons, select the authentication method and And or Or, and press Next button. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 26 3.3.1.1. Register as 1. FP Register and authenticate using the fingerprint. Default Setting: 0 This screen is available to determine the authentication level for each user to be registered. By changing this value, the different authentication level may be set for each registered user. If this value is set to 0, the 1:1 Level set in the terminal is used instead of the user-specific authentication level. After completion of setting, press the [ENT] button to move to the next setting. Enter your fingerprint referring to 1.8. How to register and enter the fingerprint as aforesaid. When the fingerprint sensor lights on, place your finger on the fingerprint input window. When Ppik buzzer occurs, wait for about 2~3 seconds until the light turns off, and lift your finger. When the first fingerprint is successfully entered, the message of Please try again is displayed. Enter the fingerprint entered just now once again. Enter the fingerprint entered just now once again. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 27 It should be noted that when entering the second fingerprint after entering the first fingerprint, you must release your finger from the fingerprint input window and then enter the second fingerprint again. When the registration is completed, select Add FP. If it fails, the screen returns to the 1. User screen. The followings show LCD prompts that may appear during the registration process. Register Success!
When registration is successful Fail!
When registration fails If the fingerprint image is unclear, or if no fingerprint is entered for ten seconds after the FP sensor lights off Duplicated FP!
If the fingerprint registered already is registered again If registration fails even if you try to repeat 2-3 times depending on the correct fingerprint registration method, it is recommended to authenticate using the card. 3.3.1.2. Register as 2. FP Register and authenticate using the card only. Place the card to register on the LCD. To cancel and exit the registration, press [ESC] button. When the registration is completed, select Add FP. If it fails, the screen returns to the 1. User menu. The followings show LCD prompts that may appear during the registration process. Register Success!
When registration is successful Fail!
When registration fails Duplicated Card!
If the card registered already is registered again 3.3.1.3. Register as FP or Card The user can be registered using both card and fingerprint and then authenticated using either card or fingerprint. The user should register his/her fingerprint (see Fingerprint Registration) and then his/her card
(see Card Registration). UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 28 3.3.1.4. Register with FP and Card The user can be registered using card and fingerprint. Authentication is performed for the card and then for the fingerprint. The user should register his/her fingerprint (see Fingerprint Registration) and then his/her card
(see Card Registration). 3.3.2. Delete User Select [F3~][1.User][2.Delete] on the main screen, and the following screen will appear. Enter the ID of the new user you wish to delete, and press
[F4] button long. Enter the ID of the user you want to delete from the registered users of the terminal and press
[F4] button long, the successful buzzer will sound and all the information will be deleted from the terminal. However, data deletion from the terminal does not mean data deletion from the server. To delete the data permanently, it must be deleted from the server as well. If the ID of an unregistered user is entered, the message of Unregister with Fail buzzer is displayed on the LCD and then the screen goes to the 1. User menu. When deleting, both general users and administrators are deleted without distinction. So you have to watch out the deletion of administrator unknowingly. If users who are not exist in the network server but registered in the terminal are deleted, the data cannot be recovered. Therefore, special cautions are required. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 29 3.3.3. Modify User Select [F3~][1.User][3.Modify] on the main screen, and the following screen will appear. Enter the ID of the user you wish to change, and press
[ENT] button long. Both general users and administrators can be changed without distinction. If the ID of an unregistered user (or administrator) is entered, the message of Unregister with Fail buzzer is displayed on the LCD and then the screen goes to the 1. User menu. The changeable items of users are different according to the user authentication method and are classified as below. Select [1] to change the authentication method; [2] to modify the authentication level; [3] to add the fingerprint to the relevant ID; and [4] to add the card. Up to 10 fingerprints/cards per ID can be registered. If you try to register more than 10 fingerprints/cards, when selecting [3] or [4], Fail buzzer occurs and the message of User FP/Card Full ! is displayed on the LCD.
[1] When selecting Auth Type By using [][] buttons, select the authentication method and And or Or, and press Next button. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 30 To modify, select the authentication methods referring to the aforementioned process of [3.3.1.1]
to [3.3.1.4].
[2] When selecting 1:1 Level Recommended Setting: 0 To modify, the new set value should be entered. If this value is set to 0, the 1:1 Level set in the terminal is used instead of the user-specific authentication level.
[3] When selecting Add FP Enter your fingerprint referring to 1.8. How to register and enter the fingerprint as aforesaid. When the fingerprint sensor lights on, place your finger on the fingerprint input window. When Ppik buzzer occurs, wait for about 2~3 seconds until the light turns off, and lift your finger. When the first fingerprint is successfully entered, the message of Please try again is displayed. Enter the fingerprint entered just now once again. Enter the fingerprint entered just now once again. It should be noted that when entering the second fingerprint after entering the first fingerprint, you must release your finger from the fingerprint input window and then enter the second UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 31 fingerprint again. When the registration is completed, select Add FP. If it fails, the screen returns to the 3. Modify menu. The followings show LCD prompts that may appear during the registration process. Register Success!
When registration is successful Fail!
When registration fails If the fingerprint image is unclear, or if no fingerprint is entered for ten seconds after the FP sensor lights off If the fingerprint registered already is registered again If ten fingerprints have been registered in the relevant ID Duplicated FP!
User FP Full!
[4] When selecting Add CARD To cancel the registration, press [ESC] button. When placing your card on the LCD, the successful buzzer occurs and the newly entered card number is added. If card change fails, the Fail buzzer occurs and the screen returns to the 3. Modify menu. The followings show LCD prompts that may appear during the registration process. Register Success!
When registration is successful Fail!
When registration fails Duplicated Card!
If the card registered already is registered again User Card Full!
If ten fingerprints have been registered in the relevant ID UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 32 3.3.4. Add Administrator Select [F3~][1.User][4.Add Admin] on the main screen, and the following screen will appear. Enter the ID of the administrator you wish to register, and press [F4] button long. Since then, the administrator registration process is same as the general user registration process. Only users registered as administrators have the authority to change the operating environment of the terminal, and register/modify/delete all the information of users saved in the terminal. Therefore, special attention is required for registration of terminal administrators. 3.3.5. Delete All Users Select [F3~][1.User][5.Delete All] on the main screen, and the following screen will appear. Select [1] to delete all users, and [2] to cancel. After requesting reconfirmation, all users including administrators are immediately deleted. Before using this function, special attention is required. After successful deletion, the successful buzzer occurs and then the screen returns to the 1. User menu. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 33 3.4. Network Setting Select [2.Network] on the main menu, and the following screen will appear. Press [][] buttons to select the menu you want to change, and press [ENT] button. 3.4.1. Terminal ID Select [F3~][2.Network] [1.Terminal ID] on the main screen, and the following screen will appear. 3.4.1.1. Terminal ID This ID is a unique ID used to allow the server to identify the terminal. The default is 00000001. Default Setting: 00000001 This ID must match the door ID set to the server program and is entered as an 8-digit number. Press [ENT] button long, and go to the next menu. 3.4.1.2. Authentication Priority [NS / SN / NO / SO] Setting Select [1] for NS, [2] for SN, [3] for NO, and [4] for SO. Default Setting: 2.SN UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 34 This menu is to determine the authentication priority between the terminal and the network, the default is 2. SN, and the authentication method in each mode operates as follows. NS SN NO SO If the terminal is connected to the server, authentication is attempted from the server. If the terminal is disconnected from the server due to a network failure, etc., authentication is attempted from the terminal. Even if the terminal is connected to the server, authentication is attempted from the terminal. The authentication result is sent to the server in real time. However, if the entered user is not registered in the terminal, authentication is attempted from the server. (If there is any fingerprint user in the terminal, the 1:N fingerprint authentication is not performed in the server.) Even if the user is registered in the terminal server, authentication is performed through the server only. Only users registered in the terminal are authenticated. If the terminal is connected to the server, the authentication result is sent to the server in real time. The authentication priority may be set flexibly depending on the situation such as the number of terminals connected to the server, the number of authenticated users, or network failure. However, if more than 10 terminals are connected to the server and so concurrent authentication is often attempted, or if network failure often occurs, it is recommended to attempt SN authentication (set to 2). After entering correctly, press [ENT] button, and the screen will go to the upper menu. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 35 3.4.2. IP Setting Select [F3~][2.Network] [2.Terminal Net] on the main screen, and the following screen will appear. 3.4.2.1. Connection Method Setting Select [1] if Static IP is assigned, and select [2] to set IP using DHCP. Default Setting: 1.Static This refers to how the terminal is connected to the network. The default is 1 (Static). Select [1] when using the Static IP assigned from the connected network, and select [2] when using the IP assigned from the DHCP server which exists in the connected network. After entering correctly, press [ENT] button to move to the next setting. If the connection method is set to Static IP (1), the following procedures such as 3.4.2.2. Terminal IP Setting, 3.4.2.3. Subnet Mask Setting, and 3.4.2.4. Gateway Setting should be set respectively. However, if the connection method is set to the dynamic IP supported by DHCP, the setting is unnecessary and so omitted. 3.4.2.2. Terminal IP Setting Press [][] buttons to move to the digit you want to change, and press [][] buttons to change the numbers Default Setting: 192.168.000.003 Set the IP address assigned to the terminal. After entering correctly, press [F4] button long to move to the next setting. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 36 3.4.2.3. Subnet Mask Setting Press [][] buttons to move to the digit you want to change, and press [][] buttons to change the numbers. Default Setting: 255.255.255.000 This is to set the subnet mask of the network connected to the terminal. After entering correctly, press [F4] button long to move to the next setting. 3.4.2.4. Gateway Setting Press [][] buttons to move to the digit you want to change, and press [][] buttons to change the numbers. Default Setting: 192.168.000.001 This is to set the gateway IP of the network connected to the terminal. After entering correctly, press [ENT] button long, and the screen will go to the upper menu. 3.4.3. Server IP Setting Select [F3~][2.Network] [3.Server Net] on the main screen, and the following screen will appear. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 37 3.4.3.1. Connection Method Setting Select [1] if Static IP is assigned, and select [2] to set IP using DDNS. Default Setting: 1.Static This is the way that the terminal is connected to the network. Select [1] when using the Static IP assigned from the connected network, and select [2] when using the IP assigned from the DDNS server. After entering correctly, press [ENT] button to move to the next setting. If the connection method is set to Static IP (1), the following procedures such as 3.4.3.2. Sever IP Setting and 3.4.3.3. Server Port Setting should be set respectively. However, if the connection method is set to 2. DDNS, DDNS ID needs to be additionally set and so 4.4.3.4. DDNS ID Setting is added. 3.4.3.2. Sever IP Setting Press [][] buttons to move to the digit you want to change, and press [][] buttons to change the numbers. Default Setting: 192.168.000.002 This is to specify the IP Address of the network server connected to the terminal. After entering correctly, press [F4] button long to move to the next setting. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 38 3.4.3.3. Sever Port Setting Press [][] buttons to move to the digit you want to change, and press [][] buttons to change the numbers. Default Setting: 09870 This is to specify the Port of the network server connected to the terminal. After entering correctly, press [F4] button long, and the screen will go to the upper menu. 3.4.3.4. DDNS ID Setting Press [][] buttons to move to the digit you want to change, and press [][] buttons to change the numbers. Default Setting: 000000001 This appears only when the server connection method is set to 2. DDNS. This is to specify the DDNS ID of the DDNS server connected to the terminal. After entering correctly, press [F4] button long to move to the next setting. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 39 3.4.3.5. DDNS IP Setting Press [][] buttons to move to the digit you want to change, and press [][] buttons to change the numbers. Default Setting: 210.116.104.058 This is to specify the IP Address of the network server connected to the terminal. After entering correctly, press [F4] button long to move to the next setting. 3.4.3.6. DDNS Port Setting Press [][] buttons to move to the digit you want to change, and press [][] buttons to change the numbers. Default Setting: 09880 This is to specify the Port of the network server connected to the terminal. After entering correctly, press [F4] button long, and the screen will go to the upper menu. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 40 3.5. Option Setting Select [3.Option] on the main menu, and the following screen will appear. Press [][] buttons to select the menu you want to change, and press [ENT] button. 3.5.1. Application Setting Select [F3~] [3.Option] [1. Application] on the main screen, and the following screen will appear. Set the operating mode that you want to set. Default Setting: 1.Access This is to set an operating mode of the terminal. Select 1 for simple access control; 2 for T&A control; and 3 for Food Service management. After selecting, press [ENT] button to move to the detail setting menu according to each operating system. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 41 3.5.1.1. When setting to [1.Access] or [2.T&A]
By setting the default time for each T&A mode, after authentication, the terminal display mode can be turned into the automatically set T&A mode. If time setting is unnecessary, it is set to 00:00-00:00. This is to set the default attendance time. Press [][] buttons to move to the digit you want to change, and press [][] buttons to change the numbers. Within the set time zone, the Attend mode is always displayed if another function key is not pressed. Even if the Leave mode is authenticated by pressing [F2] button, the terminal display mode is automatically turned into the Leave after authentication. Therefore, it is convenient to manage T&A. After <F1 Time>, set <F2 Time>, <F3 Time>, <F4 Time>, and <Access Time> in the same way. As shown below, each time zone must be set not to overlap each other.
(Ex.) F1 Time=06:00~09:59, F2 Time=17:00~22:00
<F1 Time>
06:00~09:59
<F2 Time>
17:00~22:00 Subsequently, press [ENT] button, and the following screen will appear. Default Setting: 2.No At least five authentication modes may be set if necessary. Whether to use function keys of F5~F6 is determined using F1~F3 keys. When setting to 1.Yes, press the F1(F2,F3) mode once more under the F1(F2,F3) mode, and it will be changed into the F5(F6,F7) mode. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 42 Default: 1.No This is the menu to select whether to use the printer or not. If the authentication is set to 1 or 2 with successful authentication, the Terminal ID, User ID, Date and Authentication mode are printed out through the printer connected to the RS232 port of Terminal. The printer used is SRP-350 Serial Type model. Subsequently, press [ENT] button, and the following screen will appear. Default Setting: All V Set whether to use each function key. When setting to V, it means that the authentication mode may be changed when pressing the function key. When setting to Blank, the authentication mode is not changed in spite of pressing the key. When this mode is used only for Attend or Leave, it is available by unchecking other function keys. After selecting the set value, press [ENT] button, and all authentication settings will be finished and the screen will move to the upper menu. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 43 3.5.1.2. When setting to [3.Cafeteria]
If time setting is unnecessary, it is set to 00:00-00:00. This is to set the breakfast time. Breakfast is unconditionally authenticated within the set time zone. After setting the breakfast time, set <Lunch>, <Dinner>, <Supper>, and <Snack> in order in the same way. The unused meal time is set to 00:00-00:00. Each time zone must be set not to overlap each other. When the time is not set to the food time zone, the terminal displays Locked! message. As the terminal is locked, all inputs are blocked except for access to the menu mode. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 44 When <Snack> is set, the menu to check whether to duplicate appears as shown below. Default Setting: 2.No If the mode is set to No, authentication is once allowed within the same meal time zone. When attempting authentication again, the Duplicated! message is displayed and the authentication fails. Subsequently, press [ENT] button, and the following screen will appear. Default: 1.No This is the menu to select whether to use the printer or not. If the authentication is set to 1 or 2 with successful authentication, the Terminal ID, User ID, Date and Authentication mode are printed out through the printer connected to the RS232 port of Terminal. The printer used is SRP-350 Serial Type model. Subsequently, press [ENT] button, and the following screen will appear. Default Setting: All V UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 45 Set whether to use each function key. When setting to V, it means that the authentication mode may be changed when pressing the function key. When setting to Blank, the authentication mode is not changed in spite of pressing the key. When this mode is used only for Attend or Leave, it is available by unchecking other function keys. After selecting the set value, press [ENT] button, and all authentication settings will be finished and the screen will move to the upper menu. 3.5.2. Authentication Method Setting Select [F3~] [3.Option] [2. Verify] on the main screen, and the following screen will appear. 3.5.2.1. Set whether to display ID upon successful authentication Default Setting: 2.User Name
-
-
-
-
1: displays the authenticated user ID 2: displays the user name on the LCD. If there is no user name, the user ID is displayed. But it marks Max 16 letters for English, Max 8 letters for Korean (Japanese/Chinese) 3: displays the User Key which is registered upon user registration. 4: displays the message entered upon user registration. But it marks Max 16 letters for English, Max 8 letters for Korean (Japanese/Chinese)
(Caution)
* UserName and Message are set in the server. For output, the user information must be downloaded.
* UserName and Message must be set to the same language as the terminal language.
(Example) OK!<0001>
Subsequently, press [ENT] button to move to the next setting. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 46 3.5.2.2. Set whether to permit authentication using card only Default Setting: 2.No This option makes it possible to authenticate using card only without fingerprint. Even if the user is registered in FP and Card, he/she can be authenticated using card only in the terminal that this option is set to 1. After selecting the set value, press [ENT] button, and the screen will go to the upper menu. 3.5.2.3. To authenticate only using the information saved in the Smart Card Default Setting: 2.No This option makes it possible to authenticate only using the user information and fingerprint recorded in the card without downloading users in the terminal. To operate this option, the terminal must be equipped with the SC card reader and it must be set to use the FP card. After selecting the set value, press [ENT] button, and the screen will go to the upper menu. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 47 3.5.2.4. Blocking Time Setting Default Setting: 00000 (Unit: Second) This option is to prohibit the user from re-authenticating within the set time. There is no limit when the mode is set to '0'. However, if it is set to the greater value than 0, re-authentication cannot be permitted until the time lapses more than the set time after successful authentication. After selecting the set value, press [ENT] button, and the screen will go to the upper menu. 3.5.2.5. Global Block Setting Default Setting: 2.No This option is to prohibit the user from authenticating within the short time. After successful authentication, the terminal function is blocked during the blocking time set previously. After selecting the set value, press [ENT] button, and the screen will go to the upper menu. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 48 3.5.2.6. NetErr TimeOut Network Error Time Setting (Second) Default Setting: 05 In the server authentication mode, if the network error time is set, the time to wait for authentication can be set. For example, if the error time is set to 5 seconds, when the user does not receive any response from the server for 5 seconds after authentication request, an error message comes out.
(However, the user is processed as authentication failure.) After selecting the set value, press [ENT] button, and all authentication settings will be finished and the screen will move to the upper menu. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 49 3.5.3. Door Setting Select [F3~] [3.Option] [3.Doorlock] on the main screen, and the following screen will appear. 3.5.3.1. Door Open Time Setting Default Setting: 03(Unit: Second) This option is to specify the time when after authentication through the terminal, the door is opened and then closed. Strike type means the time when if opening the door after authentication, the door is automatically locked again. In the case of Dead Bolt type and Auto Door, the door will work regardless of the value. If the mode is set to 00, it is impossible to control the door. '00' must be set only when the door is not connected to Lock. After selecting the set value, press [F4] button to move to the next setting. 3.5.3.2. Door Open Alarm Setting Default Setting: 00 This option allows the terminal to check the time when the door is open. If the door is open over the set time (minimum 5 seconds to maximum 30 seconds), an alarm occurs. When the time is set to 00, no alarm occurs. Even if the time is set to 01~04, an alarm starts to sound after the lapse of at least 5 seconds. The door must be closed within the set time. But, it may not be closed due to unforeseen circumstances. The alarm allows users to check the cause that the door is unclosed and take any action so that the door can be closed normally. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 50 To use this function, the lock must have the function to monitor whether the door is open or close. The monitoring pin of the lock must be also connected to the terminal. To check whether the door is open or close, the mode must be set to 2 or 3. After selecting the set value, press [F4] button long, and the screen will finish all the setting of the door and move to the upper menu. 3.5.4. Volume Setting Select [F3~] [3.Option] [4.Sound] on the main screen, and the following screen will appear. 3.5.4.1. Voice Volume Setting Default Setting: 3 This option is to set the volume during voice guidance. If the volume is set to 0, the voice message does not come out. Press [ENT] button to move to the next setting. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 51 3.5.4.2. Buzzer Volume Setting Default Setting: 3 This option is to set the terminal buzzer volume. The buzzer occurs silent for 0, small volume for 1, and large volume for 3. Press [ENT] button to move to the next setting. 3.5.4.3. Case Open Alarm Setting Default Setting: 1.Yes This option is to set whether an alarm occurs when the terminal case is open. The alarm occurs for 1 and it does not occur not for 2. After selecting the set value, press [ENT] button, and the screen will go to the upper menu. 3.5.6. Current Time Setting Select [F3~][3.User][6.Time] on the main screen, and the following screen will appear. 3.5.6.1. Time Synchronization Setting Default Setting: 1.Auto UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 52 This option is to set how to synchronize the current time of the terminal with the server time. Set to 1.Auto to automatically synchronize with server time, and set to 2.Manual to manually synchronize with server time. Press [ENT] button to move to the next setting. 3.5.6.2. Calendar Setting Default Setting: 1.Gregorian This option is to set how to display the current date in the terminal. The date is generally set to 1. Gregorian, but 2.Persian when using the Persian calendar specially. Press [ENT] button to move to the next setting. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 53 3.5.6.3. Current Time Setting The current time of the terminal is displayed in the order of "2009:Year, 08:Month, 01:Day, 21:Hour, 18:Min, 06:Sec". To modify, move to the desired position using [][] buttons, and modify the existing values using [][] buttons. Press [ENT] button to move to the next setting. 3.5.6.4. Time Display Setting Default Setting: 2.05:00 PM This option is how to display the current time of the terminal. When setting to 1, the time is displayed to the 24-hour time. When setting to 2, the time is displayed by separating with AM/PM. After selecting the set value, press [ENT] button, and the screen will go to the upper menu. 3.5.7. RS485 Set Select [F3~] [3.Option] [7.RS485 Set] [ENT] on the main screen, and the following screen will appear. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 54 3.5.7.1. RS485 Set This option is to set RS485 ID in order to work together with RS485 device. Press [][] buttons to select the ID value, and press
[ENT] button. Default Setting: 0 After selecting the set value, press [ENT] button, and the screen will go to the upper menu. 3.6. Terminal Information Inquiry Select [3.Information] on the main menu, and the following screen will appear. All the environmental settings of the terminal can be checked in order. Press [][] buttons and scroll them up and down, and you can in order check the settings in the following table. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 55 Version WorkMode Language Auth Mode 1:1 Level 1:n Level Terminal Id Net Type Terminal IP Gateway Subnet Mask Server Type Server IP Server Port MAC Addr Card Ver Card Format All User All Admin Max User All FP Max FP All Log Max Log Serial Num Terminal firmware version Terminal operating modes (T&A + security/T&A/food service) Language setting Authentication priority Authentication level applied when 1:1 authentication Authentication level applied when 1:n authentication Terminal ID Network connection methods (Static IP/DHCP) Terminal IP address Terminal gateway address Terminal subnet mask address Network server connection mode setting IP address of the network server connected to the terminal Port number of the network server program Terminal MAC address Card reader module firmware version Card data display format The total number of users registered in the terminal, including administrators The number of administrators registered in the terminal The maximum number of users who can be registered in the terminal The total number of fingerprints saved in the terminal The maximum number of fingerprints that can be registered in the terminal The number of the authentication results saved in the terminal The maximum number of the authentication results that can be saved in the terminal Terminal serial number 3.7. Additional Function (Extra Function) Select [5.Ext Function] on the main menu, and the following screen will appear. Press [][] buttons to select the menu you want to change, and press [ENT] button. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 56 3.7.1. Terminal Lock Setting Select [F3~][5.Ext Function][1.Lock Term] on the main screen, and the following screen will appear. Default Setting: 2 (Unlock Terminal) This function allows the administrator to directly lock or unlock the terminal without the server program. If it is set to 1, nobody can access the office until the administrator releases the set. After selecting the set value, press [ENT] button, and the screen will go to the upper menu. 3.7.2. Card Number Inquiry Select [F3~][5.Ext Function][2.Read Card] on the main screen, and the following screen will appear. This is an additional function regardless of the terminal environment setting. In the case of the terminal that the card reader is added, the card number can be checked for card registration via the server. Place the card on this screen, and the card number will be displayed on the LCD. To exit the card read, press [ESC] button to move to the upper menu. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 57 3.7.3. Monitor Input Port Setting This option acts to connect the sensor to the terminal input port, and send a notice message to the server when the status is changed. Select [F3~][5.Ext Function][3.Monitor] on the main screen, and the following screen will appear.
(Caution) DM2 is a currently unused spare port. Before using the relevant function, check the required ports and install. 3.7.3.1. Monitor 1 Input Port Setting Set when connecting an external contact to DM0. (When using a motor lock, set to 1 or 2.) Default Setting: 0.None
-
-
-
-
-
-
0.None: When nothing is connected 1.NO or 2.NC: When the open door status monitoring pin is connected 3.Fire NO or 4.Fire NC: When the fire detection sensor is connected 5.Panic NO or 6.Panic NC: When the panic situation detection sensor is connected 7.EMC NO or 8.EMC NC: When the emergency detection sensor is connected 9.Ctrler Out: When the authentication result is sent to the external controller
(Connect the REDled of controller to DM0 or DM1 through the board has the TR. Set the relevant pin to 9.Ctrler Out. WiegandOut must be set.) Press [ENT] button to move to the next setting. 3.7.3.2. Monitor 2 Input Port Setting Set when connecting an external contact to DM1. (When using a motor lock, set to 1 or 2.) Default Setting: 0.None
-
-
0.None: When nothing is connected 1.NO or 2.NC: When the open door status monitoring pin is connected UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 58
-
-
-
-
3.Fire NO or 4.Fire NC: When the fire detection sensor is connected 5.Panic NO or 6.Panic NC: When the panic situation detection sensor is connected 7.EMC NO or 8.EMC NC: When the emergency detection sensor is connected 9.Ctrler Out: When the authentication result is sent to the external controller
(Connect the REDled of controller to DM0 or DM1 through the board has the TR. Set the relevant pin to 9.Ctrler Out. WiegandOut must be set.) After selecting the set value, press [ENT] button, and the screen will go to the upper menu. 3.7.4. Duress FP Setting Select [F3~][5.Ext Function][4.Duress FP] on the main screen, and the following screen will appear. 3.7.4.1 Duress FP This function allows users to use an alarm when the duress fingerprint is entered. Set whether to use the duress fingerprint alarm. Default Setting: 2.No The default setting is '2.No'. When it is set to 1.Yes, if the pre-registered fingerprint is authenticated, the L2 Pin will output the DC12V. If any emergency detection device such as a siren is connected to this Pin, it will operate. If <Duress FP> is set to 1.Yes, the menu for setting the time corresponding to 12V will appear. Default Setting: 03 (Unit: Second) To modify, Press [][] buttons to move to the desired position, and press [][] buttons to change the existing value. After selecting the set value, press [ENT] button, and the screen will go to the upper menu. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 59 3.8. Device Setting Select [6.Device] on the main menu, and the following screen will appear. Press [][] buttons to select the menu you want to change, and press [ENT] button. Most of device settings are the option that does not need to change after installation. It is recommended that they are not changed unless there is any clear purpose. 3.8.1. System Configuration Select [F3~] [6.Device] [1. System Conf] on the main screen, and the following screen will appear. 3.8.1.1. User ID Digit Setting Default Setting: 4 This is a portion for setting the length of user ID. The length of user ID can be set to the 2~8 digit. It should be equal to the length of ID registered in the server program. If the 6-digit ID of 000075' is registered in the server program, the mode is set to 6. After setting, press [ENT] button to move to the upper menu. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 60 3.8.1.2. Language Setting Default Setting: 0.English If the language setting is changed, the voice message and the message on the LCD are changed into the set language. 3.8.2. Card Reader Format Setting Select [F3~] [6.Device] [2. Card Format] on the main screen, and the following screen will appear. Default Setting: 0.Default This option is to specify the format that displays the read card number. When setting to Hexa, the format is displayed to the hexadecimal number. When setting to Decimal, the format is displayed to the decimal number. In the device equipped with the RF (low frequency) card reader, if the mode is set to 4.Format 5 and it reads EM Card, the card number is displayed to the hexadecimal number of 10byte. 3.8.3. Fingerprint Sensor Setting Select [F3~] [6.Device] [3. FP Sensor] on the main screen, and the following screen will appear. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 61 3.8.3.1. 1:1 Level Setting Default Setting: 4 This option is to set the match degree with the same fingerprint when comparing the fingerprint on the fingerprint input window with the user fingerprint saved in the database. The higher authentication level may ensure the higher security. But it requires the relatively high concordance rate. When authenticating User ID, it high likely to deny authentication. In case of 1:1 Authentication Level, if the ID entered to the authentication level that underwent the authentication process with the ID input is 1234, this option finds the fingerprint registered to the ID of 1234 from the terminal database and compares it with the fingerprint on the fingerprint input window. However, in case of 1:1 authentication, if the 1:1 authentication level of users is not set to 0
(using the terminal authentication level), the 1:1 authentication level of users is applied. Press [ENT] button to move to the next setting. 3.8.3.2. 1:N Level Setting Default Setting: 4 This option is to set the authentication level using the fingerprint only without ID input. This option is used to find the fingerprint matched by comparing the fingerprint on the fingerprint input window with the user fingerprint saved in the database. In case of 1:N authentication, the user-specific authentication level is not set. Therefore, authentication is always based on the terminal authentication level. Press [ENT] button to move to the next setting. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 62 3.8.3.3. LFD Setting Default Setting: 1.None This option is to set the LFD level that can prevent fake fingerprints from entering. The higher LFD level may ensure the higher function that prevents the input of fake fingerprints made of rubber, paper, film, and silicon. However, too dry fingerprints may not be entered even when entering actual fingerprints. After selecting the set value, press [ENT] button, and the screen will go to the upper menu. 3.8.3.4. Similar fingerprint registration restriction setting Default Setting: 1.Yes If the mode is set to 1.Yes', this option acts to check whether a new fingerprint is the same as the pre-registered fingerprint, and to prevent the same fingerprint from being registered as the ID of another user. After selecting the set value, press [ENT] button, and the screen will go to the upper menu. 3.8.4. Wiegand Speaker Output Select [F3~] [6.Device] [4.Wiegand] on the main screen, and the following screen will appear. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 63 Default Setting: 1 This option is used only when the terminal is equipped with a separate controller operated by Wiegand input. After authentication, the following types of data are sent to the Wiegand port of the terminal. 1.None 2.26bit 3.34bit General case. The Wiegand Out port is not used. Sitecode [1 byte] + User ID [2 bytes] are transferred. User ID should be set to the 4-digit or less number. Example) SiteCode:045, UID:6543 1 00101101 0001 1001 10001111 0 Sitecode [1 byte] + User ID [3 bytes] are transferred. User ID should be set to the 7-digit or less number. However, if User ID is 8 digits, Sitecode is ignored and only User ID [4 bytes] is transferred. Example) SiteCode:001, UID:123456 0 00000001 00000001 11100010 01000000 0 4.Custom This is the user-defined setting that is available only in the server. Only checking is possible in the terminal. This option is unrelated to use the Wiegand type card reader. If the mode is set to 2 or 3, the following site code is set. Default Setting: 000 This option is available only when Wiegand Out is set to 2 or 3. The site code to send to Wiegand port including User ID is set to the value of 0~255. After selecting the set value, press [F4] button, and the screen will go to the upper menu. 3.8.4.1. Bypass Setting UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 64 Default Setting: 2.No This option is available when the Wiegand card reader is used. When the mode is set to [1], the card information entering to Wiegand In is bypassed to Wiegand Out. 3.8.5. Terminal Initialization Select [F3~] [6.Device] [5.Initialize] on the main screen, and the following screen will appear. Select [1] to initialize the set value; [2] to initialize the authentication records; [3] to initialize the factory; and [4]
to use the UDL10 to backup the DB. 3.8.5.1. Set Value Initialization Select [1] to initialize, and [2] to cancel. This option initializes all settings of the terminal except for the MAC (physical) addresses and serial numbers saved in the terminal. But, users and authentication records are not deleted. When initialization is successfully completed, the Ppiririck beep occurs and the screen moves to the upper menu. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 65 3.8.5.2. Authentication Records Initialization Select [1] to initialize, and [2] to cancel. This option deletes all authentication related logs except for set values and users. When initialization is successfully completed, the Ppiririck beep occurs and the screen moves to the upper menu. 3.8.5.3. Factory Initialization Select [1] to initialize, and [2] to cancel. This option deletes all settings, users and log information except for the MAC (physical) addresses and serial numbers saved in the terminal, and initializes the terminal to the status shipped at a factory. When initialization is successfully completed, the success buzzer occurs and then the terminal is rebooted. 3.8.5.4. UDL(USB Data Logger) Backup
-
If the UDL10 has the USB memory card is inserted, the mode moves to the sub-menu. If USB is not inserted, the warning message of Not Detected Memory is displayed. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 66 DB Backup Menu. Export Log
- Used when the log data saved in the AC2100 terminal is exported to USB.
- Data is saved with a file name of LOG.DAT in the place of USB top-level folder AC2100 folder 00000000 (8-digit terminal ID) folder LOG folder.
- Only log data can be saved, except for photos. Export User
- Used when the user data saved in the AC2100 terminal is exported to USB.
- Data is saved with a file name of USER.DAT in the unisuser folder.
- The number of exported users can be checked on the LCD. Import User
- Used when the user data (USER.DAT) saved in USB is imported into the terminal.
- The user file (USER.DAT) must be saved with a file name of USER.DAT in the unisuser folder.
- The size of imported data can be checked on the LCD. Upgrade
- Used when upgrading the terminal firmware by using the firmware data (ac2100.bin) saved in the USB.
- The firmware file is ac2100.bin. To upgrade, it must be saved with a file name of ac2100.bin in the AC2100 folder.
- The size of imported data can be checked on the LCD. Caution!!
When removing the USB or powering off the terminal during upgrading, the product may not work properly. Special caution is required. 3.8.6. External Device Setting Select [F3~] [6.Device] [6.Ext Device] on the main screen, and the following screen will appear. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 67 Default Setting: 1.None This option is available when connecting the Slave Reader using the card or fingerprint to the terminal in order to use as a secondary authentication device. The mode is set to 2 when connecting the Wiegand card reader, and 3 when connecting the SR100. Press [ENT] button to move to the next setting. Default Setting: 2.No When setting to 1.Yes, the Anti-Passback in the terminal is checked. This screen is displayed only when <Ext Device> is set to 2 or 3. This option is used to allow only authorized users to access and leave the office. To this end, the terminal and Slave Reader are installed to both the inside and outside of the door. Only users who access the office by authentication via the terminal can leave the office by authentication via the Slave Reader. When setting 1.Yes, the server authentication is unavailable. The device checks whether Passback is valid in the authentication order between the terminal and the Slave Reader. Press [ENT] button to move to the next setting. Default Setting: 0 This option is to set the authentication (T&A) mode saved from the Slave Reader. If the device is set to '0', it is saved as the current authentication mode; saved to F1 when 1, F2 when 2, Access when 3, F3 when 4, and F4 when 5. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 68 Press [ENT] button to move to the next setting. Default Setting: 1.None This screen is displayed only when <Ext Device> is not set to 3. When connecting an external device of LC010 to the terminal, the mode is set to 2.Lock Ctrl. When the terminal interlocks with MCP040, RS485 ID must be set. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 69 4. How to Use Terminal 4.1. When operating to [1.Access]
- Set to Menu 3.Option 1. Application [1.Access]. 4.1.1. Authentication Mode
- Press function keys, change to the desired authentication mode such as F1, F2, F3, F4, and then perform authentication. When perform authentication without pressing function keys specially, the mode is automatically authenticated to the access mode.
- Authentication Method F1 Authentication: Press [F1] key to change to the F1 mode, and then perform authentication. Authentication is performed without changing the mode within the time zone set to the Attend time. F2 Authentication: Press [F2] key to change to the F2 mode, and then perform authentication. Authentication is performed without changing the mode within the time zone set to the Leave time. F3 Authentication: Press [F3] key to change to the F3 mode, and then perform authentication. F4 Authentication: Press [F4] key to change to the F4 mode, and then perform authentication. Access Authentication:
Press twice [F4] key or press [F4] key long to change to the access mode, and then perform authentication. Or, perform authentication without changing the mode within the time zone set to the access time. 4.1.2. Authentication Using Fingerprint After changing the authentication mode by pressing function keys, place your finger on the fingerprint sensor. Then, the authentication result receiving the fingerprint will appear on the LCD with a voice message. At the alert status, press [F1] key to change the authentication mode to F1. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 70 Place your finger on the fingerprint sensor, and the white light is on the fingerprint input window. Keep your finger until the white light is off with a beep sound. If your fingerprint is successfully authenticated, the voice message of You are authorized comes out and a success message is displayed on the LCD. Error Message: The following messages will appear with the voice message of Place try again. When authentication fails When the fingerprint is registered but its authentication is attempted out of the access control time 4.1.3. Authentication Using Card For users who have registered to [Card] or [FP or Card], place the card on the main screen, and the beep sound will occur and the authentication result will displayed on the LCD. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 71 Press [F2] key to change the authentication mode to Leave. If your fingerprint is successfully authenticated, the voice message of You are authorized comes out and a success message is displayed on the LCD. Error Message: The following messages will appear with the voice message of Please try again. When a unregistered card is entered When the card is registered but its authentication is attempted out of the access control time For users who are registered with the [FP and Card]
Place the card on the main screen, and the beep sound occurs. The fingerprint cannot be authorized without going through the following fingerprint input process. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 72 When the lamp is on the fingerprint input window with the voice message of Please enter your fingerprint, enter your fingerprint and keep your finger until the beep sound occurs. 4.2. When operating to [2.T&A]
- Set to Menu 3.Option 1. Application [2.T&A].
-
If you set <Attend> and <Leave > under the condition that the attend time is constant, even if authentication is attempted without pressing [F1] or [F2] keys, the fingerprint is authenticated to Attend within the time zone set to Attend and to Leave within the time zone set to Leave. Therefore, users can reduce the T&A input error. 4.2.1. Authentication Mode
- Press function keys to change the authentication mode to Attend, Leave, Outdoor, Return, and Access, and then perform authentication with each authentication mode.
- Authentication Method Attend Authentication: Press [F1] key to change to the attend mode, and then perform authentication. Authentication is performed without changing the mode within the time zone set to the Attend time. Leave Authentication: Press [F2] key to change to the leave mode, and then perform authentication. Authentication is performed without changing the mode within the time zone set to the Leave time. Outdoor Authentication: Press [F3] key to change to the outdoor mode, and then perform authentication. Return Authentication: Press [F4] key to change to the return mode, and then perform authentication. Access Authentication: Press twice [F4] key or press [F4] key long to change to the access mode, and then perform authentication. Or, perform authentication without changing the mode within the time zone set to the access time. 4.2.2. Fingerprint Authentication
- Press the function key to change the T&A mode.
- Enter your fingerprint. 4.2.3. Authentication Using Card
- Press the function key to change the T&A mode.
- Place the card on the terminal. 4.3. When operating to [2.Cafeteria]
- Set to Menu 3.Option 1. Application [3.Cafeteria]. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 73
- When the mode is set to the food service control, the terminal is locked in the time other than meal times. The meal time must be set to more than one meal per person.
- LCD When it is not the meal time (No authentication attempt) The default screen during the meal time If the authentication is successful When the mode is set to Not-allowed Duplicate Authentication Unallowable, if the authentication is again attempted after successful authentication, a duplicate authentication error is displayed.
- When authenticating with the fingerprint Enter the fingerprint to receive authentication.
- When authenticating with the card Enter the card to receive authentication.
- When attempting authentication without pressing the menu key, it is automatically authenticated to [Menu 1]. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr AC-2100 Plus 74 FCC Information This device complies with part 15 of the FCC Results. Operation is subject to the following two conditions :
(1) This Device may not cause harmful interface, and
(2) This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for CLASS B digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try correct the interference by one or more of the following measures:
1.1. Reorient or relocate the receiving antenna. 1.2. Increase the separation between the equipment and receiver. 1.3. Connect the equipment into an outlet on a circuit different from that to which receiver is connected. 1.4. Consult the dealer or experienced radio/TV technician for help. WARNING Changes or modifications not expressly approved by the manufacturer could void the users authority to operate the equipment. CAUTION : Exposure to Radio Frequency Radiation. Antenna shall be mounted in such a manner to minimize the potential for human contact during normal operation. The antenna should not be contacted during operation to avoid the possibility of exceeding the FCC radio frequency exposure limit. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2017-01-19 | 0.1288 ~ 0.1288 | DCD - Part 15 Low Power Transmitter Below 1705 kHz | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2017-01-19
|
||||
1 | Applicant's complete, legal business name |
UNION COMMUNITY
|
||||
1 | FCC Registration Number (FRN) |
0019341288
|
||||
1 | Physical Address |
12F, Munjeong Daemyeong Valeon bldg
|
||||
1 |
Seoul, N/A
|
|||||
1 |
South Korea
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
t******@siemic.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
XX2
|
||||
1 | Equipment Product Code |
AC-2100PLUS
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
D**** L****
|
||||
1 | Telephone Number |
+82-2********
|
||||
1 | Fax Number |
+82-2********
|
||||
1 |
d******@unioncomm.co.kr
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 07/18/2017 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DCD - Part 15 Low Power Transmitter Below 1705 kHz | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Access controller | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
ONETECH Corp.
|
||||
1 | Name |
J******** L********
|
||||
1 | Telephone Number |
82-31********
|
||||
1 | Fax Number |
82-31********
|
||||
1 |
j******@onetech.co.kr
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 0.12880000 | 0.12880000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC