all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 1.57 MiB | February 15 2022 / August 14 2022 | delayed release | ||
1 |
|
Internal Photos | Internal Photos | 2.85 MiB | February 15 2022 / August 14 2022 | delayed release | ||
1 |
|
External photos | External Photos | 2.28 MiB | February 15 2022 / August 14 2022 | delayed release | ||
1 |
|
Label and location | ID Label/Location Info | 224.61 KiB | February 15 2022 | |||
1 | BOM | Parts List/Tune Up Info | February 15 2022 | confidential | ||||
1 | Block | Block Diagram | February 15 2022 | confidential | ||||
1 |
|
FCC Short & Long Term Confidentiality Request Rev4.1 | Cover Letter(s) | 70.27 KiB | February 15 2022 | |||
1 |
|
LetterofAuthorizationRev1.0 | Cover Letter(s) | 22.16 KiB | February 15 2022 | |||
1 | OP | Operational Description | February 15 2022 | confidential | ||||
1 | SCH | Schematics | February 15 2022 | confidential | ||||
1 |
|
Test Report | Test Report | 707.51 KiB | February 15 2022 | |||
1 |
|
Test Setup Photos | Test Setup Photos | 720.55 KiB | February 15 2022 / August 14 2022 | delayed release |
1 | User Manual | Users Manual | 1.57 MiB | February 15 2022 / August 14 2022 | delayed release |
UBio-X Slim User Guide Version Eng-0.3 Copyright 2000 By Union Community Co., LTD. UBio-X Slim User Guide 2
<Revison History>
Version Date Description Firmware Version 2019-03-15 Initial Release 2019-03-25 Modify some words 2019-04-25 Modify the Menu titles according to Terminals Menu modes. 0.1 0.2 0.3 UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 3
<Glossary>
Admin, Administrator 1 to 1 Verification Card. card is used for comparison. 1 to N Identification fingerprint information. registered. Authentication level
- A user who can enter into the terminal menu mode, he/she can register/modify/delete terminal users and change the operating environment by changing settings.
- If there is no administrator for a terminal, anyone can change the settings. In this regard, it is recommended to register at least one administrator.
- Caution is required with registration and operation because an administrator has the right to change critical environmental settings of the terminal.
- Authenticate the users fingerprint after inserting his user ID or swiping his registered
- It is called 1 to 1 Verification because only the fingerprint registered in the users ID or
- The terminal performs matches against multiple fingerprints (templates) based solely on
- Without the users ID or card, the users fingerprint is compared to fingerprints previously
- Depending on the fingerprint match rate, it is displayed from 1 to 9. Authentication is successful only if the match rate is higher than the set level.
- The higher the Authentication level, the higher the security. However, it requires a relatively high match rate, so Authentication is vulnerable to failure.
- 1:1 Level: Authentication level used for 1:1 verification
- 1:N Level: Authentication level used for 1:N identification LFD (Live Finger Detection)
- This function allows the input of only real fingerprints and blocks the input of imitation fingerprints produced using rubber, paper, film, and silicone. UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 4 Contents
<Revison History> ............................................................................................................... 2
<Glossary>........................................................................................................................... 3 Contents .............................................................................................................................. 4 1. Before use ........................................................................................................................ 6 1.1. Safety Precautions ................................................................................................. 6 1.2. Specific names of the terminal ............................................................................. 7 1.3. LCD Display Composition ..................................................................................... 8 1.3.1 Status Icons .................................................................................................. 8 1.4. Voice and Beep sounds in operation .................................................................... 8 1.4.1 Beep or Sound effect in operation ............................................................... 9 1.5. Proper fingerprint registration and input methods .............................................. 9 2. Product introduction ..................................................................................................... 11 2.1. Product characteristics ....................................................................................... 12 2.2. Product components ........................................................................................... 13 2.2.1. Standalone use (Access) ........................................................................... 13 2.2.2. Connected with Server (Access, Attendance) .......................................... 13 2.3. Product specification ........................................................................................... 14 3. Environment setting ...................................................................................................... 15 3.1. Checks before setting the environment ............................................................. 15 3.1.1. Entering the menu by Administrator ......................................................... 15 3.2. Menu composition ............................................................................................... 16 3.3. User ....................................................................................................................... 18 3.3.1. Register ....................................................................................................... 19 3.3.2. Modify .......................................................................................................... 20 3.3.3. Delete........................................................................................................... 20 3.3.4. List ............................................................................................................... 21 3.3.5. Card Only .................................................................................................... 21 3.4. Auth....................................................................................................................... 22 3.4.1. Normal ......................................................................................................... 23 3.4.2. TnA .............................................................................................................. 23 3.4.3. Timezone ..................................................................................................... 24 3.4.4. Log ............................................................................................................... 24 3.5. System .................................................................................................................. 25 3.5.1. Sensor ......................................................................................................... 26 3.5.2. Card ............................................................................................................. 26 3.5.3. Door ............................................................................................................. 27 3.5.4 RS485 ........................................................................................................... 27 3.5.5 Option ........................................................................................................... 28 3.5.6 Information ................................................................................................... 28 3.6. Network................................................................................................................. 29 3.6.1. Normal ......................................................................................................... 29 3.6.2. TCP/IP .......................................................................................................... 30 3.7. UI ........................................................................................................................... 30 3.7.1. Sound .......................................................................................................... 31 3.7.2. Display ......................................................................................................... 31 3.8. USB ....................................................................................................................... 32 3.8.1. F/W Update .................................................................................................. 32 3.9. Initialize................................................................................................................. 33 4. How to use terminal ...................................................................................................... 34 UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 5 4.1. How to open the door .......................................................................................... 34 4.2. How to punch for TnA .......................................................................................... 36 UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 6 1. Before use 1.1. Safety Precautions Warning Handling with wet hands or allowing liquid to flow into it is prohibited.
-> It may cause an electric shock or damage. Do not disassemble, repair, or modify the terminal at discretion.
-> It may cause an electric shock, fire or damage. from direct Keep away sunlight
-> It may cause deformation or color change. Avoid using water, benzene, for thinner, or alcohol cleaning
-> It may cause an electric shock or fire. Do not contaminate fingerprint input area.
-> Fingerprints may not be the well recognized. impacts or using the objects Avoid sharp terminal.
-> The terminal may be on damaged and broken. Do not place a fire source near the terminal.
-> It may cause a fire. Keep out of reach of children.
accident or damage. It may cause an Avoid high humidity or dust
-> The terminal may be damaged. Do not place a magnet close to the terminal.
-> The terminal may break down or malfunction. Avoid using insecticide or flammable spray near the terminal.
deformation change. result or in color It may Avoid severe temperature changes
-> The terminal may be broken.
- If the above warning is ignored, it may result in death or serious injury. Cautions
- If the above cautions are ignored, it may result in property loss or human injury. Under no circumstances will UNION COMMUNITY be responsible for accidents or damages caused by inappropriate use of the product without referring to the user manual. UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 7 1.2. Specific names of the terminal Camera Flash Camera Daylighting sensor Touch LCD Card Sensing Area Fingerprint sensor UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 8 1.3. LCD Display Composition Status Icons Time & Date ID Input Button Menu Button 1.3.1 Status Icons Network Status Fire Alarm Tamper
: Standalone Mode (Non-networking Mode)
: Connected to the server (On line)
: Disconnected to the server (Off line)
: Fire Alarm is activated (by the Fire switch or by Server program)
: Abnormal Status (Tamper switch is activated) None None
: Normal Status
: Normal Status
: Door is closed Door Status
: Door is opened
: Door is opened abnormally UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 9 1.4. Voice and Beep sounds in operation Operation type Voice sound Success to authorize You are authorized Fail to authorize Please try again Waiting for input FP Please place your finger Waiting for input Card Please place your card Touch the ID Input button Please insert your ID 1.4.1 Beep or Sound effect in operation 1.5. Proper fingerprint registration and input methods Correct fingerprint registration methods Pi-pick Notice for fail When the authorization was failed (at Voice off) Peek Ding-dong
Notice Success for When the authorization was successful (at Voice off) Place your index finger on the window just as you do with a finger stamp. Do not use the tip of the finger. Make sure the center of your finger touches the window. a stable input method. Use your index finger if possible, it is the easiest for orientation and guarantees Check if your fingerprint is unclear or damaged. It is tricky to recognize fingerprints on dry, wet, unclear, or injured fingers. Use another finger in this case. UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 10 Be aware of certain fingerprint conditions Depending on the users fingerprint condition, some fingerprints may not be used or may cause an inconvenience. If the fingerprint is damaged or very unclear, then it cannot be recognized. Please use the RF Card instead in this case. When a finger is dry, breathe on the finger for smooth operation. For kids, it may be tricky or impossible to use the terminal because their fingerprints are too small or very unclear. It is recommended to register their fingerprints every six months. For the elderly, it may not be possible to register their fingerprints if there are too many fine lines on the fingerprints. It is recommended that you register more than 2 fingerprints. In order to increase the fingerprint authentication rate, it is recommended to use six of the ten fingers as illustrated above. (Both thumbs, forefingers, middle fingers). UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 11 2. Product introduction 2.1. Product characteristics RF Card (125 kHz) Wi-Fi (optional). Multi-Modal product with which the user can use fingerprint, Card or Password authorization functions together. Built-in Camera Flash can detect the real human face or a picture. Camera Flash can be activated automatically by the Daylighting sensor. This is Access Control System can be cooperated with Server Database by TCP/IP or Various registration and authorization methods Fingerprint Card Password Fingerprint registration Fingerprint authorization Card registration Card authorization Password registration Password authorization OR Combination Authentication To be authorized successfully, one method among the registered should be authorized. AND Combination Authentication To be authorized successfully, all registered Auth methods should be authorized. UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 12 2.2. Product components 2.2.1. Standalone use (Access) DC12V Adapter Electric lock
(Lock+, Lock-, Monitor) 2.2.2. Connected with Server (Access, Attendance) TCP/IP Internet /
WAN / LAN TCP/IP TCP/IP TCP/IP TCP/IP TCP/IP Fingerprint authorization server Remote management program
(user and terminal setting management) Attendance management program UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 13 2.3. Product specification Types CPU LCD Memory SPEC Remarks 1.4GHz Quad Core CPU 4.95 inches Touch LCD(480*854) eMMc 8G Bytes Flash 2GByte RAM External USB support Backup data / Upgrade firmware Camera Still Capture Image Color (1600x1200) Camera Flash Sensor Daylighting Flash Control Lock Control EM, Strike, Motor Lock, Auto Door Capacity Temperature /
Humidity AC / DC Adapter I/O Communication Port 500,000 Users / 500,000 Cards 10,000,000 Logs / 50,000 Image logs
-20 ~60 /
Lower than 90% RH INPUT : Universal AC100 ~ 250V OUTPUT : DC 12V 3.5A
(Option : DC 24V) UL, CSA, CE Approved 4 In(1 Exit, 3 Monitors) 2 Out ( 2 Locks) TCP/IP (10/100Mbps) RS-232 RS-485 Wiegand Input / Output Communication with Auth Server Ticket Printer Communication with Controller Communication with Card reader or Controller Card Reader 125KHz RF Dimension (mm) 80 X 195.6 X 23.5(Normal) / 54.67(Max) Including Bracket UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 14 3. Environment setting 3.1. Checks before setting the environment 3.1.1. Entering the menu by Administrator Terminal users include general users and administrators. General users are only allowed to open the door while the administrator can use the Administrator menu to control the door as well as the terminals functions. 1. To enter the menu, touch the MENU button at the lower of the touch pad. 2. Input the administrator ID and follow the authentication process. The Administrator menu will be displayed. Because no users have yet been registered, any user can enter the Administrator menu. At least one administrator for should be registered for security purposes. 1. 2. If no administrator was designated and only general users were registered in network mode, all users will be allowed to enter the Management menu. If 1:N authentication is used, an administrator with a registered fingerprint can enter the Administrator menu using fingerprint authentication without entering his ID UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 15 3.2. Menu composition The Administrator menu has seven submenus as shown below. The following describes each sub menu:
1. User 2. Auth 1:1 Auth Level (Default : 5) 1:N Auth Level (Default : 8) Auth Type (Default : Use Identify (1:N Auth)) Auth Order
(Default : Terminal Server) TnA Type (Default : Not Use) Auto TnA (Default : Not Use) TnA only (Default : Not Use) 1. Register 2. Modify 3. Delete 4. List 5. Card Only 1. Normal 2. TnA 3. Timezone 4. Log UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 16 3. System 1. Sensor Capture Time Out (Default : 5 seconds) 2. Card 3. Door LFD Accuracy (Default : Not Use) Use Camera (Default : Not Use) Card Type (Default : Not Use) Wiegand Type (Default : Not Use) Transfer Data (Default : Card Number) Site Code Door Select (Default : Door1) Door Function (Default : Door) Lock Control Type (Default : Normal Close) Lock Open Time (Default : 5 seconds) Door Warning Time (Default : 20 seconds) Door Control Type (Default : Normal Close) ID length (Default : 4) Saving Log (Default : Yes) User Name Display (Default : Yes) Message Display Time (Default : 1 second) Tamper Alarm (Default : Mute) User / Template Admin TnA mode Card Type Network Type IP Address Version (Firmware KernelFile System) 4. RS485 RS485 Type (Default : Not Use) RS485 ID (Default : 0) 5. Option FP Template Count (Default : 2) 6. Information Terminal ID (Default : 1) UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 17 4. Network 1. Normal Network Type (Default : Wireline) 2 TCP/IP DHCP (Default : Not Use) 5. UI 1. Sound Sound Type (Default : Effect Only) 2. Display Terminal ID (Default : 1) Server IP (Default : 192.168.0.2) Port Number (Default : 7332) Encryption (Default : DES) Ping Time (Default : 10 seconds) IP Address (Default : 192.168.0.3) Subnet mask (Default : 255.255.255.0) Gateway (Default : 192.168.0.1) Main DNS Volume (Default : 1) Language (Default : English) LCD Brightness (Default : 3) Main Display (Default : Analog Clock) Waiting Time (Default : 3 minutes) Screen Saver Date (Default : System Date) Time (Default : System Time) 6. USB 1. User Download 7. Initialize 1. Delete User 2. User Upload 3. Log Download 4. F/W Update 2. Delete Log 3. Initialize Option 4. Restart UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 18 3.3. User When you select the [User] at the main menu, the following window appears. Administrator can do register, delete, modify, search for the user by using the User menu. 3.3.1. Register The maximum number of users to enroll to the terminal are 200,000 templates for FP users but Card users or PW user can be enrolled up to 500,000 users. For example, when 10,000 users have 200,000 FP templates totally stored on the terminal, 490,000 users have the Card or PW can be registered on the terminal additionally. 1. To register a new user to the terminal, select [Menu] [User]
2.
[Register] in order. Insert the User ID you want to give after pressing the button Input ID. 3. When selecting the button [Admin] from Permission, this users privilege will be changed. Basically there are two buttons to select the users privilege between administrator and normal user. The first registered user from terminal will be an administrator automatically. Administrator and normal user have the different privilege as below.
User : Access door only
Admin : Access door + Enter the menu mode of terminal To finish registration of user from the terminal, at least more than one Auth method should be registered among FP, Card, PW. And then the user will be registered when pressing the button
[SAVE] after selecting Auth combination. UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 19 3.3.2. Modify When modifying the registered user from the terminal, Group, Permission, FP, Card, PW, Auth combination can be modified freely except User ID because it is an unique identifying number so that it couldnt be modified after registration. And also it is possible on Standalone mode which the network type is Not Use. So you have to modify the registered user from the Server software on Network mode. 1. To modify the registered user from the terminal, select [Menu]
[User] [Modify] in order. And then the user information will be shown as left picture after inserting the User ID whose want to be modified. 2. To finish modification of user info from the terminal, press the button [SAVE] after modifying the user info which is wanted. 3.3.3. Delete To delete the registered user from the terminal, select
[Menu] [User] [Delete] in order. And then press the button [enter] after inserting the User ID whose want to be deleted. When pressing the button [Close], the deletion will be cancelled. If inserting invalid User ID or an unregistered User ID, Error message will be displayed but if inserting valid User ID or registered User ID, the below window will be shown. UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 20 To query the registered user list from the terminal, select [Menu] [User] [List] in order. The model UBio-X Slim realizes more convenient to control the door by Card only without using fingerprint or password. The button [Card Only] is used easier to enroll the Card users seamlessly but this feature should be worked under network mode. 3.3.4. List 3.3.5. Card Only To enroll the card users seamlessly from the terminal, select [Menu] [User] [Card Only] in order. And then the message Place your card will be shown as left picture. If swiping new card to the terminal, the card user can be enrolled easily as creating a new User ID automatically. For authorizing the registered card, you can swipe the card from the terminal without inserting User ID. 3.4. Auth Select [Menu] [Auth] in order from the terminal, the below picture will be shown. UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 21 This menu is to configure the Authentication option, TnA mode, Timezone and to search the log information. 3.4.1. Normal To set the Verify Level(1:1), Identify Level(1:N), Auth Type and Auth Sequence from the terminal, select [Menu] [Auth]
[Normal] in order. Verify Level / Identify Level Security Level for FP is adjustable per each Auth Type. For Verify Level(1:1), default is 5 but it can be selected from 1 to 9. For Identify Level(1:N), default is 8 but it can be selected from 5 to 9. Security Level is too higher, FRR(False Rejection Rate) is more increasingly but it is too lower, FAR(False Acceptance Rate) is more increasingly. So please use the default value if not special case. These are applied to all users except the user has the individual setting on registration. Auth Type The model UBio-X Slim supports both 1:1 and 1:N Auth Types. When using 1:1, insert the User ID or swipe his registered Card before placing his registered finger. But using 1:N, place your finger without input User ID or swipe the Card because UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 22 3.4.2. TnA matching the fingerprint against all user data. However, if you want to be authenticated faster, to use 1:1 is better than to use 1:N even 1:N is more convenient than 1:1. Auth Sequence automatically. automatically.. only. There are 4 Auth Sequence modes in UBio-X Slim. And these are operated with Server software.
- Server Terminal : Authentication starts by Server and if it was not searched, authentication will be started by Terminal
- Server Only : Authentication should be done by Server only.
- Terminal Server : Authentication starts by Terminal and if it was not searched, authentication will be started by Server
- Terminal Only : Authentication should be done by Terminal When using TnA mode, the user should press the Function key before authentication, and then the authentication log will be transferred with the pressed function key number. It makes manage the TnA efficiently when pressing each Function key for employees situation. (F1(Attend), F2(Leave), F3(Out), F4(In)) There are three TnA types in UBio-X Slim and it is selectable among Simple, Normal, Expand. Simple type has 2 Function keys and Normal type has 4 Function keys, Expand type supports the multiple Function keys up to 63keys. Simple & Normal types have the fixed function keys as below.
(F1 : Attend / F2 : Leave / F3 : Out / F4 : In) In case Expand type, the Function keys are editable freely by software administrator. 3.4.3. Timezone UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 23 If using the feature terminals timezone, it is possible to grant to access or deny to access per each period or per each time. But this feature can be used to set the door access on Network mode only. timezone. It is possible to set the timezone for each terminal or for each user with selecting the button Type. The time table consists Day and Time as the left picture and it can be checked the terminals timezone or a configured users 3.4.4. Log Caution for setting the timezone The timezone is set the server management software only so that it is not possible to set it on the terminal. This is the feature to check the authentication logs for the terminals user. UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 24 3.5. System Select [Menu] [System] in order from the terminal, the below picture will be shown. This menu is to configure Sensor, Card, Door, Option for Door and check the terminals information. 3.5.1. Sensor This menu is used to set the Sensor Mode, Capture Timeout, LFD Accuracy, Sensor Brightness for the fingerprint sensor. And when selecting the terminal basic sensor setting, this setting will be applied to all users who are registered as selecting not individual sensor setting. Capture Timeout This is the standby time for capturing fingerprint and it is adjustable from 3 to 9 seconds. (Default : 5 seconds) LFD(Live Finger Detection) Accuracy This menu is used to set the level to inspect the fake finger and to use it. This is graded from 0 to 3 as below. Not use(0), Low(1), Middle(2), High(3) Camera Usage This menu is set the camera using condition. For example, the camera will be operated for authentication success when selecting Success. And when selecting All, the camera will be operated regardless of authentication success. When selecting Not Use, the fingerprint image or other suitable image will be displayed. UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 25 3.5.2. Card This menu is used to set the Card authentication for terminals It is selectable among Not Use, EM, MIFARE, HID26Bit, HID35Bit, HID37Bit, iClass26bit, iClass35bit, iClass37bit. Wiegand Type Send Data It is used to set the Wiegand Out. It is used to select the Wiegand Out data between Card Number to User ID. When selecting User ID, 4 digits User ID will be out after authentication success via Wiegand Out but when selecting Card Number, the card serial number(CSN) will user. Card Type be out. Site Code below. This option is used only on selecting User ID and it can be out differently per each Wiegand bit between 26bit and 34bit as
- Site Code for Wiegand 26bit : 0 ~ 255
- Site Code for Wigand 34bit : 0 ~ 32767 UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 26 3.5.3. Door There are two functions on this menu. one is able to control two doors and the other is able to support the Fire alarm or lighting lamp after connecting each external device. It is selectable among Not Use, Door, Fire Alarm, Light It is selectable between Normal Close, Normal Open for lock Function Alarm. Lock Control control type. Lock Open Time It can be set the door open time. Door Warn Time It can be set the time for door open too long. Door Control It is selectable for door monitoring sensor type between Normal Close, Normal Open. This menu is used to set the external device is communicated to UBio-X Slim via RS485. RS485 Type RS485 ID It is selectable between Not Use and BLC010. When using RS485 communication with the external controller, UBio-X Slim device should be given the RS485 ID differently from 0 to 7 as a reader. 3.5.4 RS485 UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 27 3.5.5 Option This menu is used to set other terminal options as the left picture. The option Number of Template decides the fingerprint count and the option ID Length on user enrollment. So all registered users on terminal must be deleted before changing these two options. Number of Template It is selectable between 1 to 2. (Default : 2) ID Length Log Save It is selectable from 4 to 20. (Default : 4) It decides to save the log for authentication result. It decides to display the user name when authentication Display User Name success. Duration Result It decides the displaying time for the authentication result. Tamper Alarm It decides to mute for Tamper Alarm. This menu gives information about the terminal as the left picture. this is not editable but the read only menu for Terminal ID, Stored user & template counts, Number of admin, TnA mode, Network Type Terminal IP address, Firmware version, etc. 3.5.6 Information UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 28 3.6. Network Select [Menu] [Network] in order from the terminal, the below picture will be shown. There are two sub menus Normal and TCP/IP under [Network]
as the left picture. 3.6.1. Normal There are two modes Network mode and Standalone mode on UBio-X Slim model. And the Network mode divided by Wireline and Wireless. Type It is selectable among Not Use, Ethernet, WIFI. If selecting Not Use, terminal is worked as a Standalone mode which is operated independently without connecting network. In this case, authentication is proceeded on the internal database of the terminal only. But if selecting Ethernet or WIFI, terminal is worked as a Network mode is cooperated with the Server software. Meanwhile, the mode WIFI is not serviced currently but it will be added on next. Terminal ID Terminal ID should be given differently from 1 to 2000 because it is the unique ID. It is not duplicable. Server Address It should be inserted for IP address of the Server PC which is UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 29 installed the Server software. Port Number between server to terminal. Ping Period It should be inserted for the communication port number It decides the polling duration to check the communication status between server to terminal. It is given from 2 to 20.
(Default : 10 seconds) 3.6.2. TCP/IP The options on [TCP/IP] should be configured properly to connect to the server after selecting Network mode. DHCP It is decided when selecting Use between Use and Not Use. When using DHCP, the terminal IP address cannot be changed. Because it obtains automatically. When not using DHCP, IP Address, Subnet Mask and Default Gateway for terminal should be given manually. To obtain them, contact the network administrator on the customer site. What is DHCP (Dynamic Host Configuration Protocol)?
This feature is to assign automatically the IP address of the terminal including Subnet Mask and Gateway by DHCP Server to use TCP/IP communication. So if it is On, it makes to use more convenient. UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 30 3.7. UI Select [Menu] [UI] in order from the terminal, the below picture will be shown. This menu is used to set the terminal display option and sound option as the left picture. And it makes to change freely as customer wants for the terminals main display, language, date
& time, sound, etc. 3.7.1. Sound This menu is used to set the Sound type about both voice &
effect and control its volume. UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 31 3.7.2. Display Language Language for terminal can be selected which you want to use. This is adjustable from 1 to 5 and default is 3. It is selectable among Analog Clock, Digital Clock, Logo LCD Brightness Main Display Image. Date & Time Terminals data & time is adjustable manually on the Standalone mode. 3.8. USB Select [Menu] [USB] in order from the terminal, the below picture will be shown. This menu is used to upload or to download the user data or log data via USB memory. Basically, this feature works all options User Download, User Upload, Log Download on Standalone mode but on network mode, it is possible to use Log Download only. UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 32 3.8.1. F/W Update It is possible to update the firmware by using USB memory. When selecting the target file from the firmware file list as left picture, terminal will be rebooted automatically after finishing updating as showing below picture. 3.9. Initialize Select [Menu] [Initialize] in order from the terminal, the below picture will be shown. This menu is used to set back to the factory format for all terminals user data, stored log data and configured options. So please be cautious for these initialization because it is not recoverable. UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 33 4. How to use terminal 4.1. How to open the door There are two below methods to open the door with authentication from the terminal basically. 1:1 Verification This 1:1 Verification can access the door much faster regardless of the number of users on the terminal because it compares only between the inserted fingerprint to the stored fingerprint of the pressed As shown in the figure below, press the button [ID] to input the registered User ID first and then input the fingerprint or password after pressing the button [enter]. User ID. UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 34 1:N Identification This method is that the registered fingerprint is placed on the fingerprint sensor in the main screen without inserting User ID. But it can take somewhat long time to authenticate because it compares the inserted fingerprint to all fingerprint data in spite of much more convenient then 1:1 Verification. Fingerprint Authentication Insert the fingerprint on the fingerprint sensor without inputting User ID. Card Authentication Swipe the Card on the Card Sensing Area without inserting User ID. If the User ID should be pressed certainly before inserting fingerprint, please check terminal option Use Identify is not selected. 1:N Identify for password user is same to 1:1 Verify. UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 35 4.2. How to punch for TnA In TnA mode, user must click function key before authentication. And the log is transferred to server with information which function key is selected. If the function key was not pressed on authentication, it is possible not to record the TnA type firmly for users Attend, Leave, Out, In. So it should be pressed for each case before authentication. UBio-X Slim model displays the Function keys on the bottom side as following pictures. Simple TnA mode In this mode, the User ID is pressed after pressing Function key and then try to authenticate. The function keys in Simple TnA mode are defined as below.
- F1: Attend
- F2: Leave If the function key is pressed before authentication, the pressed key F1 or F2 will be recorded on the authentication logs so that they are used on Time & Attendance software. Normal TnA mode In this mode, the User ID is pressed after pressing Function key and then try to authenticate. The function keys in Normal TnA mode are defined as below.
- F1: Attend
- F2: Leave
- F3: Out
- F4: In If the function key is pressed before authentication, the pressed key F1to F4 will be recorded on the authentication logs so that they are used on Time & Attendance software. UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 36 Expand TnA mode In this mode, the Function keys on the bottom side as the left picture. When pressing the function key Expand, the User ID is pressed after pressing Function key number which you want up to 63 and then try to authenticate. If you want to use 1:N identification on TnA mode, try to authenticate directly When selecting TnA Only to use, the Function key MUST be pressed for after pressing Function key without inserting User ID. authentication. UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr UBio-X Slim User Guide 37 FCC Suppliers Declaration of Conformity Nitgen / Ubio-x Slim FCC Information This device complies with part 15 of the FCC Results. Operation is subject to the following two conditions :
(1) This Device may not cause harmful interface, and
(2) This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for CLASS B digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try correct the interference by one or more of the following measures:
1.1. Reorient or relocate the receiving antenna. 1.2. Increase the separation between the equipment and receiver. 1.3. Connect the equipment into an outlet on a circuit different from that to which receiver is connected. 1.4. Consult the dealer or experienced radio/TV technician for help. WARNING equipment. body. Changes or modifications not expressly approved by the manufacturer could void the users authority to operate the FCC RF Radiation Exposure Statement:
This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. CAUTION : Exposure to Radio Frequency Radiation. Antenna shall be mounted in such a manner to minimize the potential for human contact during normal operation. The antenna should not be contacted during operation to avoid the possibilityof exceeding the FCC radio frequency exposure limit. Contains FCC ID: XX2-F1DC2706-A Supplier Name: Virdi USA Inc information: +1 917 559 3365 Supplier Address (USA): 8900 Winnetka Ave, Northridge, CA 91324, USA Supplier phone number and / or internet contact UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr
1 | Internal Photos | Internal Photos | 2.85 MiB | February 15 2022 / August 14 2022 | delayed release |
1 | External photos | External Photos | 2.28 MiB | February 15 2022 / August 14 2022 | delayed release |
1 | Label and location | ID Label/Location Info | 224.61 KiB | February 15 2022 |
Page 1 of 1 IDENTIFICATION LABEL:
PROPOSED FCC ID LABEL The FCC ID shall be permanently affixed in the rear side of the equipment
1 | FCC Short & Long Term Confidentiality Request Rev4.1 | Cover Letter(s) | 70.27 KiB | February 15 2022 |
UNION COMMUNITY Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: February 10, 2022 Subject; Request for Confidentiality FCC ID: XX2-UBIO-XSLIMRF To Whom It May Concern, Pursuant to the provisions of the Commissions rules Title 47 Sections 0.457 and 0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure External Photos Test Setup Photos Internal Photos User Manual In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR 2.803 and the importation rules in Title 47 CFR 2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s);
OR For 45 days, pursuant to Public Notice DA 04-1705. For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Name: Dong Ho, Lee Title: Manager
1 | LetterofAuthorizationRev1.0 | Cover Letter(s) | 22.16 KiB | February 15 2022 |
Letter of Authorization Seoul, South Korea
: UNION COMMUNITY
: 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Company Address Product Name : Access controller Model Number : UBio-X Slim RF FCC Identifier : XX2-UBIO-XSLIMRF We authorize MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the above named equipment. Any individual within MiCOM Labs is authorized to act on our behalf and take action on the application. We declare that MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Name: Dong Ho, Lee Title: Manager Date: February 10, 2022 Signature of applicant:
1 | Test Setup Photos | Test Setup Photos | 720.55 KiB | February 15 2022 / August 14 2022 | delayed release |
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2022-02-15 | 0.12391 ~ 0.12391 | DCD - Part 15 Low Power Transmitter Below 1705 kHz | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2022-02-15
|
||||
1 | Applicant's complete, legal business name |
UNION COMMUNITY
|
||||
1 | FCC Registration Number (FRN) |
0019341288
|
||||
1 | Physical Address |
12F, Munjeong Daemyeong Valeon bldg 127 Beobwon-ro Songpa-gu
|
||||
1 |
12F, Munjeong Daemyeong Valeon bldg
|
|||||
1 |
Seoul, N/A
|
|||||
1 |
South Korea
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
c******@micomlabs.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
XX2
|
||||
1 | Equipment Product Code |
UBIO-XSLIMRF
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
D**** L******
|
||||
1 | Telephone Number |
+82-2********
|
||||
1 | Fax Number |
+82-2********
|
||||
1 |
d******@unioncomm.co.kr
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
UNION COMMUNITY
|
||||
1 | Physical Address |
South Korea
|
||||
1 |
d******@unioncomm.co.kr
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 08/14/2022 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DCD - Part 15 Low Power Transmitter Below 1705 kHz | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Access controller | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
ONETECH Corp.
|
||||
1 | Name |
K******** N****
|
||||
1 | Telephone Number |
82-31********
|
||||
1 | Fax Number |
82-31********
|
||||
1 |
k******@onetech.co.kr
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 0.12391000 | 0.12391000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC