eNBioAccess-T2 User Guide Version eng-2.00 Copyright 2013, NITGEN Co., Ltd. All rights reserved.
`
It is strictly prohibited to compile, duplicate or publish part. Or whole of this manual prior written consent of NITGEN. The specification of this product may be changed without prior notice to improve its functionality. The logo of NITGEN&COMPANY is a registered trademark of NITGEN Co., Ltd. Other names or trademarks are registered trademarks of their respective owners. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 2
<Revison History >
Version Date Description Firmware Version 1.00 1.10 1.20 2016-07-15 Initial Release 2016-08-17 Modified the description for icon information. 2016-09-01 EMC Open function Deletion LOCK1/LOCK2 Result Output Menu Deletion 1.30 2016-09-19 User Logo Description Addition Terminal <-> LC015B Interface modification Added the some description for User Input in Backup Menu 1.40 1.50 2016-09-29 Added the picture for Backup Error 2016-11-18 Modified the range for Door open time Modified the type of card module
(0=NONE,1=SC,2=EM,3=HID) 1.60 1.70 2016-12-01 Modified the range for open alarm time 2017-01-20 Fix similar fingerprint check part when registering fingerprint (Check when there are 200 fingerprint templates or less) Added the description for authentication time in FP Sensor menu. 1000-01 1000-02 1000-04 1000-05 1000-06 1000-14 1000-16 1000-23 1.80 1.90 2.00 2017-08-09 Added default setting for DM2. 2017-08-28 Added the screen for Upgrading firmware 2017-09-12 Added the description for 1.4 section 1000-27 1000-28 1000-29
- LOCK OPEN STATE LED Changed the description for 3.1.4 section
- the level value for matching FP 1:N 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 3
<Glossary >
Administrator (Admin)
- The administrator can access the terminal menu mode. He/she has the authority to add/modify/delete terminal users and to change the operating environment by changing settings.
- If there is no registered administrator in the terminal, anybody can access to the terminal menu and change settings. It is recommended that more than one administrator will be necessarily registered in the terminal.
- The administrator has the authority to change critical environmental settings of the fingerprint reader. So, special attention is required to its registration and operation. 1:1 Authentication
- The user fingerprint is verified after entering User ID or Card.
- Only User ID or the user fingerprint registered to the card is compared. This is called One-to-One Authentication. 1: N Identification
- The user is searched only by the fingerprint.
- The same fingerprint as the input fingerprint is identified among the registered fingerprints without User ID or Card entered. This is called One-to-N Identification. Authentication Level
- As a level used for fingerprint authentication, it is displayed in Step 1 to 9. Authentication cannot be allowed before the degree of match between two fingerprints is higher than the set authorization level.
- The higher authentication level may ensure the higher security. But it requires the relatively high concordance rate. When authenticating User ID, it high likely to deny authentication.
- 1:1 Level: Authentication level applied when 1:1 authentication
- 1: N Level: Authentication level applied when 1: n authentication Authentication Method
- It refers FP(Fingerprint)Authentication, RF(Card)Authentication and a various types of authentication methods made by each of a combination. LFD (Live Finger Detection): Fake fingerprint prevention function
- The LFD allows only actual fingerprints to be entered, except for any fake fingerprints made of rubber, paper, film, and silicon and the like. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 4 1. 2. 3. Table of Contents Before Getting Started ................................................................................. 6 1.1. Safety Notes ........................................................................................................ 6 1.2. Product Details ................................................................................................... 7 1.2.1. FRONT ...................................................................................................... 7 1.2.2. REAR ......................................................................................................... 8 Input / Output ............................................................................................. 9 1.2.3. 1.3. Screen information during operation .............................................................. 12 Initial Screen ............................................................................................ 12 1.3.1. Icons ........................................................................................................ 12 1.3.2. 1.3.3. Function KEY ........................................................................................... 13 1.3.4. Main Screen ............................................................................................. 13 1.4. LED information during operation ................................................................... 15 1.5. Voice information during operation ................................................................. 15 1.6. Buzzer guide announced during operation .................................................... 15 1.7. How to register and enter the correct fingerprint ........................................... 16 Product Descriptions ................................................................................. 17 2.1. Product Features .............................................................................................. 17 2.2. Diagram ............................................................................................................. 18 2.2.1. Single Type (Door Lock) ........................................................................... 18 2.2.2. Single Type (Lock Controller) ................................................................... 18 2.2.3. Dummy Type (MCP040) ........................................................................... 18 2.2.4. Network Type (Door Lock) ........................................................................ 19 2.2.5. Network Type (Lock Controller) ................................................................ 19 2.3. Product Specification ....................................................................................... 20 Environment Setting .................................................................................. 21 3.1. Checkpoints before Environment Setting ....................................................... 21 3.1.1. Menu ........................................................................................................ 21 3.1.2. Administration authentication ................................................................... 21 3.1.3. How to access the menu without administrator authentication ................. 22 3.1.4. Save Settings ........................................................................................... 22 3.1.5. Default Setting ......................................................................................... 23 3.1.6. Setting guide for Network Configuration ................................................... 24 3.2. How to register the terminal in Admin App ..................................................... 27 Install iAccess M Plus................................................................................ 27 Execute and Log in iAccess M Plus ........................................................... 27 Access to Terminal BLE REDAY ................................................................. 27 Terminal login Admin App ......................................................................... 28 Administrator authentication of the terminal ............................................ 28 Terminal registration ................................................................................. 28 3.3. Access Device with Admin App ....................................................................... 29 3.4. Access and Registration between ACM Pro and terminal ............................. 30 Install ACM Pro ......................................................................................... 30 3.4.1. Execute ACM Pro ...................................................................................... 30 3.4.2. Set in terminal .......................................................................................... 31 3.4.3. 3.4.4. LAN connection in terminal ....................................................................... 31 3.4.5. Register the terminal in ACM Pro .............................................................. 32 3.5. Menu Configuration .......................................................................................... 33 3.6. USER ................................................................................................................. 39 3.2.1. 3.2.2. 3.2.3. 3.2.4. 3.2.5. 3.2.6. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 5 3.9. 3.6.1. Menu Configuration .................................................................................. 39 ADD.......................................................................................................... 39 3.6.2. 3.6.3. AUTO ADD ................................................................................................ 41 3.6.4. MODIFY .................................................................................................... 42 3.6.5. DELETE .................................................................................................... 43 3.6.6. DELETE ALL .............................................................................................. 43 3.7. Network Menu ................................................................................................... 44 3.7.1. Menu Configuration .................................................................................. 44 3.7.2. AUTH Mode .............................................................................................. 45 Terminal ID .............................................................................................. 45 3.7.3. Terminal ................................................................................................... 46 3.7.4. 3.7.5. Server....................................................................................................... 47 3.8. Option Menu...................................................................................................... 48 3.8.1. Menu configuration .................................................................................. 48 ATTEND .................................................................................................... 48 3.8.2. 3.8.3. Screen ...................................................................................................... 50 SAVE ........................................................................................................ 52 3.8.4. TIMEOUT.................................................................................................. 53 3.8.5. 3.8.6. LOCKING .................................................................................................. 54 INT DEVICE ....................................................................................................... 56 3.9.1. Menu Configuration .................................................................................. 56 FP SENSOR ............................................................................................... 56 3.9.2. BEEP ........................................................................................................ 58 3.9.3. 3.9.4. VOICE ...................................................................................................... 58 BLE ........................................................................................................... 58 3.9.5. 3.9.6. TAMPER .................................................................................................... 59 3.10. EXT DEVICE ...................................................................................................... 60 3.10.1. Menu Configuration .................................................................................. 60 3.10.2. DOORLOCK .............................................................................................. 60 3.10.3. RS485....................................................................................................... 63 3.10.4. WIEGAND ................................................................................................. 64 3.11. STATUS ............................................................................................................. 67 3.11.1. Menu Configuration .................................................................................. 67 3.11.2. DB INFO ................................................................................................... 67 3.11.3. NETWORK ................................................................................................ 67 3.11.4. OPTION .................................................................................................... 68 3.11.5. INT DEVICE .............................................................................................. 68 3.11.6. EXT DEVICE ............................................................................................. 68 3.11.7. I/O PORT .................................................................................................. 68 3.11.8. VERSION .................................................................................................. 69 3.12. RECOVERY ....................................................................................................... 70 3.12.1. Menu Configuration .................................................................................. 70 3.12.2. INITIALIZE ............................................................................................... 70 3.12.3. SELF TEST ................................................................................................ 71 3.12.4. BACKUP .................................................................................................... 75 3.12.5. REBOOT ................................................................................................... 77 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 6 1. Before Getting Started 1.1. Safety Notes Keep the terminal away from inflammables.
- > Otherwise, it may cause a fire. Warning Do not operate the terminal with wet hands, and pay attention not to let any liquid such as water enter inside the terminal.
- > Otherwise, malfunction or electric shock may be caused. Do not disassemble, repair or remodel the terminal at your disposal.
- > Otherwise, it may cause malfunction, electric shock, or a fire.
- Non-compliance of safety notes may cause death or serious injury for users. Cautions Do not install the terminal in a place exposed to direct sunlight. Otherwise, it may cause malfunction, deformation and discoloration. Do not allow children to touch terminal carelessly.
- > Otherwise, it may cause safety accidents of children or malfunction. Do not install the terminal in humid or dusty places. Otherwise, it may cause malfunction. the Do not clean this terminal by sprinkling water, nor wipe it with benzene, thinner, and alcohol. Otherwise, it may cause electric shock or a fire. Keep the fingerprint input section clean. fingerprint cannot recognized correctly. Otherwise, the be Keep the terminal away from shock or sharp objects. Otherwise, it may damage the terminal and result in malfunction. Keep the terminal away from magnets. Otherwise, cause malfunction. failure it may and Do not spray insecticides or inflammables on the terminal. Otherwise, it may cause deformation and discoloration. Do not install the terminal in a place where there is a severe change in temperature. Otherwise, cause malfunction. it may
- Non-compliance of safety notes may cause personal injury or property damage for users. We are not responsible for any accidents and damage that may arise from non-
compliance of the information in this manual. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 7 1.2. Product Details 1.2.1. FRONT BLE embedded State LED Fingerprint Sensor Camera LCD Function KEY (F1~F4) Speaker Card Sensor (EM/SC/HID) USB assist device
(UDL10) connection 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 8 1.2.2. REAR Fixed bracket Cable harness 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 9 1.2.3. Input / Output 1.2.3.1. Cable & Connector 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 10 1.2.3.2. Pin Details Line color Label Explanation IN/OUT Note Pin number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 ORANGE YELLOW GREEN BLUE BLACK RED BLACK GREEN BLUE ORANGE YELLOW BROWN PURPLE BLACK RED BLACK GREEN WHITE RED BLACK RED GRAY BROWN WHITE PURPLE BLACK BLACK
(Line name) EXT DM0 DM1 DM2 GND Inside open DoorMonitor0 DoorMonitor1 DoorMonitor2 GND 5V PGND DC5V Power GND R4A R4B WO0 WO1 WI0 WI1 GND
-
-
-
-
12V RS485A RS485B WIE_OUT0 WIE_OUT1 WIE_IN0 WIE_IN1 GND N_TXN N_TXP N_RXN N_RXP DC12V IN IN IN IN
-
OUT
-
BI BI OUT OUT IN IN
-
OUT OUT IN IN IN GND Power GND
-
12V L1C L1NC L1NO L2 GND DC12V LOCK1_COM LOCK1_NC LOCK1_NO LOCK2 GND PGND Power GND OUT OUT OUT OUT OUT
-
-
-
connection Connect to Exit button Sense door state(DM0) Sense door state(DM1) Sense door state(DM2) Ground connection(for door monitor) DC 5V output Power supply ground connection RS-485 interface RS-485 interface Output WIGAND (WO0) Output WIGAND (WO1) Input WIGAND (WI0) Input WIGAND (WI1) Ground
(WIGAND signal) LAN I/F (LAN cable) LAN I/F (LAN cable) LAN I/F (LAN cable) LAN I/F (LAN cable) DC 12V power supply input Power supply ground connection (Adapter) DC 12V put out power Lock1 COM terminal Lock1 NC terminal Lock1 NO terminal Lock2 terminal Ground
(Lock connecter) Power supply ground connection
(Lock power) Panel connection (Earth) connection ground 28 BLACK PGND Panel GND 1.2.3.3. Terminal <- > MCP040 wiring Category RS485A RS485B ground connection T2 terminal (Line name) R4A (green) R4B (blue) GND (black) MCP040 RDRA+
RDRA-
G 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 11 1.2.3.4. Terminal <- > LC015B wiring Category RS485A RS485B ground connection DOOR MONITOR INSIDE OPEN DC12V (LC015B separate power supply) ground connection (Power only for LC015B) T2 terminal (Line name) R4A (green) R4B (blue) GND (black) LC015B 485A 485B GND IN1(If this pin is not used, connect to GND Pin.) IN0 DC12V IN GND But, door open time can be set with DIP SWITCH of LC015B (Maximum open time is 5 sec.) 1.2.3.5. Terminal <- > EM Type Door Lock wiring Category Lock GND Door Monitor T2 terminal (Line name) EM Door Lock L1NC (Green) GND (Black) DM0 (Black)
+
-
NC(Normal Close) 1.2.3.6. Terminal <- > WIEGAND Device wiring Category T2 terminal (Line name) WIEGAND INPUT0 WIEGAND INPUT1 WIEGAND OUTPUT0 WIEGAND OUTPUT1 GND WI0() WI1() WO0() WO1() GND () WIEGAND Device Wiegand output0 Wiegand output1 Wiegand input0 Wiegand input1 GND 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 12 1.3. Screen information during operation 1.3.1. Initial Screen When powering on at first, the screen is displayed as follow. State icon 1.3.2. Icons Server connection State Gate State Warning signal State Fire detection State BLE connection State MCP040 connection State UDL connection State Operation Mode TNA Mode Date and Time NONE
: No use network NONE NONE NONE NONE
: LAN line is disconnected.
: LAN line is connected. (Only link is connected.)
: Connected with server
: Gate is closed.
: Gate is opened.
: Gate is opened forcedly(unusual door open state)
: Gate communication problem
: Normal
: Terminal Disassembly State
: Normal
: Sensed by fire detector(Valid on DM2 fire set)
: Disconnected with Admin App
: Connected with Admin App
: MCP040 is not used.(Normal state)
: MCP040 Mode and bad communication state.
: MCP040 Mode and normal communication state. NONE
: UDL is not used (Normal state).
: UDL is connected. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 13 1.3.3. Function KEY Icon Meaning Function Key Explanation F1 F3 F2 F2 long F4 F4 long or F4 Move cursor up. Move cursor down. Move cursor to left. Move to upper menu. Move cursor to right. Move to submenu. F2 Category choice (ENABLE or DISABLE). UP DOWN LEFT ESC RIGHT ENTER ENABLE DISABLE 1.3.4. Main Screen Operating in Exclusive mode Initial Screen Operating in Network mode Initial Screen Operating in Dummy mode Initial Screen Operating in lock mode
(Reject all users authentication) 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 14 Menu of Initial Screen Authentication succeess Authentication failure Waiting for Card Input Waiting for Fingerprint Input Waiting for Admin App registration Upgrading firmware for eNBioAccess-T2 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 15 1.4. LED information during operation LED Operating state Remark RED GREEN BLUE Function Key LED Normal Alarm Authentication Failure Normal LOCK OPEN Authentication Success Terminal Normal(alive) Enter menu OFF ON or Flash ON (Maintain during authentication time) OFF OFF ON ON (Maintain during authentication time) OFF Flash at intervals of 5 seconds Always ON Touch in initial screen. ON(Maintain for 10 seconds) OFF 1.5. Voice information during operation Category Voice information Fingerprint Input Please enter your fingerprint. You are authorized. Authentication success Authentication failure 1.6. Buzzer guide announced during operation Please try again. Buzzer Sound State Explanation Ppik Key touch Card tag Fingerprint touch Ppibik Failure Ppiriririk Waiting for input Ppiririk Succeess
-Pressing key or reading card
-When inputting fingerprint, input has been completed and hands can take off. If authentication fails or the user's input is wrong It shows the state for waiting users input such as fingerprint or password. Authentication completion success or setting 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 16 1.7. How to register and enter the correct fingerprint Correct fingerprint input method Enter your fingerprint as if you take a thumbprint by using your forefinger if possible. The fingerprint cannot be correctly registered and entered only by your fingertips. The center of the fingerprint should be touched with the fingerprint input section. Enter the fingerprint of your forefinger if possible. When using your forefinger, you can enter your fingerprint correctly and safely. Make sure that the fingerprint is unclear or wounded. Too dry, wet, blurry or wounded fingerprints are difficult to recognize. In this case, the fingerprint of another finger should be registered. Precautions subject to your fingerprint state. The availability of the fingerprint may vary subject to your fingerprint state. This product consists of a fingerprint recognition system and cannot recognize the damaged or unclear fingerprints. The fingerprint should be registered using the RF card. If your hands are dry, you can blow your breath on the system to operate it more smoothly. For children, too small or unclear fingerprints may be difficult or impossible to use. They need to register a new fingerprint every six months. For seniors, the fingerprint with too many lines may not be registered. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 17 It is recommended that you will register more than two fingerprints if possible. In order to increase the fingerprint authentication rate, it is recommended to use six of the ten fingers as illustrated below (both thumbs, forefingers, middle fingers). 2. Product Descriptions 2.1. Product Features BLE is equipped. Door Control with smartphone is possible at close range. It is equipped with Color Camera, and it saves the visitors video when authentication succeeds or fails. Optional, Available to use as RF(125kHz), Smart Card(13.56MHz), HID Reader Easy to verify your ID via fingerprint
- The use of the fingerprint recognition technology (Biometrics) can prevent forgetting your password, losing your card or key, or avoid the risk of their theft. The use of personal fingerprints enhances the security of authentication. Access control system using the local area network (LAN)
- The fingerprint reader communicates with the authentication server using a TCP/IP protocol. Therefore, this terminal can be applied to the existing LAN and has easy expandability. It ensures a fast speed by 10/100 Mbps Auto Detect and facilitates management and monitoring via the network. Provide various registration and authentication method Fingerprint Card Fingerprint registration Fingerprint authentication Card registration Card authentication Card or Fingerprint Card, Fingerprint registration Card or Fingerprint authentication Card and Fingerprint Card, Fingerprint registration Fingerprint authentication after Card authentication Mobile card Mobile Card registration (registration only via server and admin App) Mobile Card authentication 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 18 Close Open Close Open Door Lock Lock Controller
(LC010, LC015) T2 T2 RS485 BLE 2.4G BLE 2.4G Lock control 2.2. Diagram 2.2.1. Single Type (Door Lock) Mobile App 2.2.2. Single Type (Lock Controller) Mobile App 2.2.3. Dummy Type (MCP040) RS485ID
#1 RS485ID
#3 RS485ID
#2 Lock/Open Lock/Open Lock/Open RS485 T2 Ethernet MCP040 Server 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 19 BLE 2.4G Lock Control 2.2.4. Network Type (Door Lock) Mobile App 2.2.5. Network Type (Lock Controller) Ethernet Internet T2 Door Lock Close Open Ethernet Server BLE 2.4G RS485 Mobile App Close Open T2 Lock Controller
(LC010, LC015) Ethernet Ethernet Internet Server 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 20 2.3. Product Specification Category CPU MEMORY Camera LCD Fingerprint Sensor Authentication Method Authentication Speed Fingerprint capacity Log capacity Spec 32Bit RISC CPU(400MHz) 64M DDR RAM, 32M NOR,128M NAND VGA, F2.8, View angle 61 degree 1.77 Color LCD Optical / 500 DPI Fingerprint, RF Card, Mobile Card 1:N < within1sec. (based on 1,000 fingerprints) 20,000 Fingerprints, 10,000 users (Two identical fingerprints registration per user) Note) Similar fingerprint inspection is possible when the number of fingerprints is less than 200. 100,000 logs Communication interface TCP/IP, Wiegand In/Out (26/34bit),RS485 Lock Deadbolt, EM Lock, Door Strike, Automatic Door Temperature /
Humidity Certification Size
-20~60 / < RH 90%
KC, CE, FCC 58mm(W) * 191mm(H) * 62mm(D) 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 21 3. Environment Setting 3.1. Checkpoints before Environment Setting 3.1.1. Menu Press F4 long until the menu screen is displayed. It is available to enter the menu without authentication because the manager doesnt register when shipping the product. 3.1.2. Administration authentication When the administrator is registered, the admin authentication screen is displayed at first as follows. Administrator authentication Administrator authentication is progressed with fingerprint and card. You can access each menu if the authentication succeeds. Admin authentication is displayed only if there is a registered user. Admin authentication displays only if admin is enrolled already. The admin authentication is needed only in accessing menu mode. It enables to access every menu until you completely escape from main menu. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 22 3.1.3. How to access the menu without administrator authentication This is the method to enter the Menu in exceptional cases such as losing your administrator card that is registered in the terminal or inability to make a fingerprint authentication because of absence of administrator. Power terminal OFF. Disassemble device and make case open state. While case opens, make DIP of rear side switch ON state as follows. ON 1 2 OFF ON Power terminal ON. After the terminal completely booted, Press F1 longer to enter the menu with buzzer sound Ppiririk. Caution: You should return DIP SWITCH OFF after modification. 3.1.4. Save Settings If there are some changes, the following screen appears. If you select YES, then save them with buzzer sound Ppibibig and reboot. If there are no changes, it returns to the previous menu screen. While changing the settings in the menu, if there is no input for 30 seconds, it returns to the previous menu. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 23 3.1.5. Default Setting Category Default setting USE TN 1 STATIC IP:192.168.0.3 SN:255.255.255.0 GW:192.168.0.1 IP:192.168.0.2 PORT: 7332 F1~F4 NO English YES NO 4 YYMMDD Yes No 1sec 30sec 60sec NO USE 5 8 NONE 5sec 3 3 Alarm STRIKE/OK 3sec MENU > NETWORK MENU > NETWORK > USE > AUTH MODE MENU > NETWORK > USE > TEMINAL ID MENU > NETWORK > USE > TEMINAL >
MENU > NETWORK > USE > TEMINAL > STATIC >
MENU > NETWORK > USE > SERVER MENU > OPTION > ATTEND > TYPE MENU > OPTION > ATTEND > AUTO TNA MENU > OPTION > SCREEN > LANGUAGE MENU > OPTION > SCREEN > SHOW ID MENU > OPTION > SCREEN > USER LOGO MENU > OPTION > SCREEN > USER ID LEN MENU > OPTION > SCREEN > DATE > FORMAT MENU > OPTION > SAVE > LOG SAVE MENU > OPTION > SAVE > IMAGE SAVE MENU > OPTION > TIME OUT > RESULT MENU > OPTION > TIME OUT > NET ERROR MENU > OPTION > TIME OUT > PING MENU > OPTION > LOCKING MENU > INT DEVICE > FP SENSOR > 1:1 LEVEL MENU > INT DEVICE > FP SENSOR > 1:N LEVEL MENU > INT DEVICE > FP SENSOR > LFD LEVEL MENU > INT DEVICE > FP SENSOR > AUTH TIME MENU > INT DEVICE > BEEP MENU > INT DEVICE > VOICE MENU > INT DEVICE > TAMPER MENU > EXT DEVICE > DOORLOCK > LOCK1 > TYPE MENU > EXT DEVICE > DOORLOCK > LOCK1 > OPEN TIME MENU > EXT DEVICE > DOORLOCK > LOCK2 > TYPE MENU > EXT DEVICE > DOORLOCK > LOCK2 > OPEN TIME MENU > EXT DEVICE > DOORLOCK > OPEN ALARM MENU > EXT DEVICE > DOORLOCK > DM0 MENU > EXT DEVICE > DOORLOCK > DM1 MENU > EXT DEVICE > DOORLOCK > DM2 MENU > EXT DEVICE > RS485 > TYPE MENU > EXT DEVICE > RS485 > DEV ID MENU > EXT DEVICE > WIEGAND > WIE-INPUT MENU > EXT DEVICE > WIEGAND > WIE-OUTPUT MENU > EXT DEVICE > WIEGAND > WIE-OUTPUT> 26 BIT or 34 BIT > SITE CODE MENU > EXT DEVICE > WIEGAND > WIE-OUTPUT> 26 UID 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com None 3sec 5sec NONE NONE NONE NONE 0 NONE NONE 0 eNBioAccess-T2 User Guide 24 BIT or 34 BIT > SITE CODE > SEND INFO 3.1.6. Setting guide for Network Configuration 3.1.6.1. Single Type (Door Lock=STRIKE) Menu position MENU>NETWORK>
MENU>EXT DEVICE>DOORLOCK>LOCK1>TYPE MENU>EXT DEVICE>DOORLOCK>DM0 MENU>EXT DEVICE>DOORLOCK>LOCK2>TYPE MENU>EXT DEVICE>DOORLOCK>DM1 MENU>EXT DEVICE>DOORLOCK>DM2 MENU>EXT DEVICE>RS485>TYPE 3.1.6.2. Single Type (Door Lock=MOTOR) Menu position MENU>NETWORK>
MENU>EXT DEVICE>DOORLOCK>LOCK1>TYPE MENU>EXT DEVICE>DOORLOCK>DM0 MENU>EXT DEVICE>DOORLOCK>LOCK2>TYPE MENU>EXT DEVICE>DOORLOCK>DM1 MENU>EXT DEVICE>DOORLOCK>DM2 MENU>EXT DEVICE>RS485>TYPE 3.1.6.3. Single Type (Lock Controller=LC010) Menu position MENU>NETWORK>
MENU>EXT DEVICE>DOORLOCK>LOCK1>TYPE MENU>EXT DEVICE>DOORLOCK>DM0 MENU>EXT DEVICE>DOORLOCK>LOCK2>TYPE MENU>EXT DEVICE>DOORLOCK>DM1 MENU>EXT DEVICE>DOORLOCK>DM2 MENU>EXT DEVICE>RS485>TYPE MENU>EXT DEVICE>RS485>DEV ID 3.1.6.4. Single Type (Lock Controller=LC015) Menu Position MENU>NETWORK>
MENU>EXT DEVICE>DOORLOCK>LOCK1>TYPE MENU>EXT DEVICE>DOORLOCK>DM0 MENU>EXT DEVICE>DOORLOCK>LOCK2>TYPE MENU>EXT DEVICE>DOORLOCK>DM1 MENU>EXT DEVICE>DOORLOCK>DM2 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com Possible setting NO USE STRIKE/OK N/O or N/C NONE NONE NONE NONE Possible setting NO USE MOTOR1 N/O or N/C MOTOR2 N/O or N/C NONE NONE Possible setting NO USE NONE NONE NONE NONE NONE LC010 0 Possible setting NO USE NONE NONE NONE NONE NONE eNBioAccess-T2 User Guide 25 MENU>EXT DEVICE>RS485>TYPE MENU>EXT DEVICE>RS485>DEV ID 3.1.6.5. Dummy Type (RS485=MCP040) Menu Position MENU>NETWORK>
MENU>EXT DEVICE>DOORLOCK>LOCK1>TYPE MENU>EXT DEVICE>DOORLOCK>DM0 MENU>EXT DEVICE>DOORLOCK>LOCK2>TYPE MENU>EXT DEVICE>DOORLOCK>DM1 MENU>EXT DEVICE>DOORLOCK>DM2 MENU>EXT DEVICE>RS485>TYPE MENU>EXT DEVICE>RS485>DEV ID 3.1.6.6. Network Type (Door Lock=STRIKE) Menu Position MENU>NETWORK>
MENU>NETWORK>USE>AUTH MODE MENU>NETWORK>USE>TERMINAL ID MENU>NETWORK>USE>TERMINAL>STATIC MENU>NETWORK>USE>SERVER MENU>EXT DEVICE>DOORLOCK>LOCK1>TYPE MENU>EXT DEVICE>DOORLOCK>DM0 MENU>EXT DEVICE>DOORLOCK>LOCK2>TYPE MENU>EXT DEVICE>DOORLOCK>DM1 MENU>EXT DEVICE>DOORLOCK>DM2 MENU>EXT DEVICE>RS485>TYPE 3.1.6.7. Network Type (Door Lock=MOTOR) Menu Position MENU>NETWORK>
MENU>NETWORK>USE>AUTH MODE MENU>NETWORK>USE>TERMINAL ID MENU>NETWORK>USE>TERMINAL>STATIC MENU>NETWORK>USE>SERVER MENU>EXT DEVICE>DOORLOCK>LOCK1>TYPE MENU>EXT DEVICE>DOORLOCK>DM0 MENU>EXT DEVICE>DOORLOCK>LOCK2>TYPE MENU>EXT DEVICE>DOORLOCK>DM1 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com LC015 0 Possible setting N/A
(Use : When only downloading DB) NONE NONE NONE NONE NONE MCP040 Use in 1~7 Possible setting USE TN 0001 IP:192.168.0.3 SN:255.255.255.0 GW:192.168.0.1 IP:192.168.0.2 PORT:7332 STRIKE/OK N/O or N/C NONE NONE NONE NONE Possible setting USE TN 0001 IP:192.168.0.3 SN:255.255.255.0 GW:192.168.0.1 IP:192.168.0.2 PORT:7332 MOTOR1 N/O or N/C MOTOR2 N/O or N/C eNBioAccess-T2 User Guide 26 MENU>EXT DEVICE>DOORLOCK>DM2 MENU>EXT DEVICE>RS485>TYPE 3.1.6.8. Network Type (Lock Controller=LC010) Menu Position MENU>NETWORK>
MENU>NETWORK>USE>AUTH MODE MENU>NETWORK>USE>TERMINAL ID MENU>NETWORK>USE>TERMINAL>STATIC MENU>NETWORK>USE>SERVER MENU>EXT DEVICE>DOORLOCK>LOCK1>TYPE MENU>EXT DEVICE>DOORLOCK>DM0 MENU>EXT DEVICE>DOORLOCK>LOCK2>TYPE MENU>EXT DEVICE>DOORLOCK>DM1 MENU>EXT DEVICE>DOORLOCK>DM2 MENU>EXT DEVICE>RS485>TYPE MENU>EXT DEVICE>RS485>DEV ID 3.1.6.9. Network Type (Lock Controller=LC015) Menu Position MENU>NETWORK>
MENU>NETWORK>USE>AUTH MODE MENU>NETWORK>USE>TERMINAL ID MENU>NETWORK>USE>TERMINAL>STATIC MENU>NETWORK>USE>SERVER MENU>EXT DEVICE>DOORLOCK>LOCK1>TYPE MENU>EXT DEVICE>DOORLOCK>DM0 MENU>EXT DEVICE>DOORLOCK>LOCK2>TYPE MENU>EXT DEVICE>DOORLOCK>DM1 MENU>EXT DEVICE>DOORLOCK>DM2 MENU>EXT DEVICE>RS485>TYPE MENU>EXT DEVICE>RS485>DEV ID NONE NONE Possible setting Use TN 0001 IP:192.168.0.3 SN:255.255.255.0 GW:192.168.0.1 IP:192.168.0.2 PORT:7332 NONE NONE NONE NONE NONE LC010 0 Possible setting USE TN 0001 IP:192.168.0.3 SN:255.255.255.0 GW:192.168.0.1 IP:192.168.0.2 PORT:7332 NONE NONE NONE NONE NONE LC015 0 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 27 3.2. How to register the terminal in Admin App 3.2.1. Install iAccess M Plus iAccess M Plus is the smartphone App for administrator controlling device via BLE. You can download and install it from Play Store. For more details, please refer iAccess M Plus installation guide. 3.2.2. Execute and Log in iAccess M Plus 3.2.3. Access to Terminal BLE REDAY If you press F3 long on initial screen, the terminal turns to BLE READY. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 28 3.2.4. Terminal login Admin App When the terminal is BLE REDAY, press ADD on iAccess M Plus App and select the terminal. If you know the administrator's ID and password, then click OK to log in. If you do not know the administrators ID & password and click OK in empty state. 3.2.5. Administrator authentication of the terminal If an administrator is registered in the terminal, it requires to input card or fingerprint for administrator authentication. If the administrator is not registered in the terminal, it requires no further authentication and authentication succeeds immediately. Input admins card or fingerprint Ppiririk Success
& output Buzzer sound 3.2.6. Terminal registration When admin authentication is successful, Device registration screen is displayed. Press Registration button and complete Device registration. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 29 3.3. Access Device with Admin App If the terminal registration on Admin App is successful, the list is displayed as follows. When pressing View, the pop-up window is displayed to connect the terminal. If the administrator is registered in the terminal, it requires the administrator authentication. If there is no administrator, the login succeeds immediately. If the login is successful, you receive the list of users registered with the Admin App screen. BLE icon is displayed on the terminal. When you log out after finishing the setting from Admin App, BLE icon disappears from the initial screen of the terminal. If it is successful to access, it is available to add / delete user, inquire log data, modify the setting and etc. For more details, please refer the document for Administrator App user guide. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 30 3.4. Access and Registration between ACM Pro and terminal 3.4.1. Install ACM Pro When shipping the product, it installs ACM Pro Program in PC from the provided CD. For installation guide, please refer the relevant document. 3.4.2. Execute ACM Pro If executing the program, login screen is displayed. Enter User ID that is previously registered and password and then press OK. If login is successful, the screen is displayed as follows. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 31 3.4.3. Set in terminal In order to connect the terminal to the server, set to the network mode and set the information. Move to MENU > NETWORK > USE > TERMINAL and check whether lower information is correct or not. If you have not changed the device network information, it is displayed as follows. In order to access the server Move to MENU > NETWORK > USE > SERVER and check the lower information correctly sets or not. If you do not change the server network information, it is displayed as follows. 3.4.4. LAN connection in terminal At first, you can see the unregistered state because the terminal is not registered. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 32 3.4.5. Register the terminal in ACM Pro Select the unregistered terminal and press Registration button to activate the screen below. Enter device name and explanation to press OK. If the registration is successful, the screen is displayed as follow. For more details about ACM pro operation, please refer ACM Pro guide document. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 33 3.5. Menu Configuration The whole menu is composed of seven, and main characteristics are as follows. Menu Submenu1 Submenu2 Submenu3 USER ADD USER INPUT ID
*Authentication Type Card FP MCARD
*Authentication Condition OR AND MCARD is OR condition only. MCARD is not admitted to set up, state check only. Password FP Card INPUT ID
*Authentication Type Card FP MCARD
*Authentication Condition OR AND MCARD is OR condition only. AUTO ADD MODIFY USER ADMIN UID > FP1 > FP2 >
OK UID > Card > OK MCARD is not admitted to set up, state check only. FP registration
(When checking authentication mode) Card registration
(When checking authentication mode) Delete ID DELETE DELETE ALL 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 34 NETWORK NO USE USE Operate in single mode AUTH MODE TERMINAL ID STATIC DHCP SERVER STATIC DHCP OPTION ATTEND TYPE SCREEN SAVE TIMEOUT Date AUTO TNA LANGUAGE ENGLISH(0) KOREAN(1) INDONESIAN(2) MULTILINGUAL(3) ARABIC(4) SPANISH(5) PORTUGUESE(6) FRENCH(7) RUSSIAN(8) FARSI(9) JAPANESE(10) CHINESE(11) SHOW ID USER LOGO USER ID LEN LOG SAVE IMAGE SAVE RESULT NET ERROR PING FORM 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com Server/Terminal Terminal/Server Server Terminal TERMINAL ID IP Subnet mask Gateway SERVER Port No NONE M1 F1~F2 M2 F1~F4 M3 F1~F49 NO YES NO YES NO USE USE 4~16 NO YES NO YES YYMMDD DDMMYY MMDDYY eNBioAccess-T2 User Guide 35 INT DEVICE FP SENSOR SETTING 1:1 LEVEL (1~9) 1:N LEVEL (5~9) LFD LEVEL BEEP VOICE BLE TAMPER AUTH TIME 0~3 0~5 BLE READY NO ALARM ALARM DOOR LOCK LOCK1 EXT DEVICE LOCK2 OPEN ALARM TIME DM0 DM1 DM2 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com YYYYMMDD-hhmmss NONE LOW MIDDLE HIGH
*TYPE Not Use Strike/OK Indication Motor1 Schedule alarm
*OPEN TIME 3[1~20sec]
* TYPE NONE Fail Indication Motor2 Schedule alarm
* OPEN TIME 3[1~20sec]
5[0~20sec]
0: No Alarm 1~20: Alarm NONE Lock Normal Open Lock Normal Close NONE Lock Normal Open Lock Normal Close Not use Normal Open Normal Close Fire Normal Open Fire Normal Close Panic Normal Open Panic Normal Close Urgent Norm Open Urgent Normal Close eNBioAccess-T2 User Guide 36 NONE LC010 LC015 SR100 MCP040
*TYPE NONE WIE26BIT WIE34BIT CUSTOM
*TYPE NONE WIE26BIT WIE34BIT CUSTOM
*SiteCode
*More Information UID CARD RS485 TYPE WIEGAND DEV ID: 0~255 WIE-INPUT WIE-OUTPUT STATE DB INFO NETWORK OPTION USER CNT:
USER MAX:
ADMIN:
FP CNT:
FP MAX:
CARD CNT:
CARD MAX:
M.CD CNT:
LOG CNT:
LOG MAX:
TID: xxxx NET: YES, MODE:TN NET TYPE: STATIC ENCRYPT: DES CIP/SN/GW---------
xxx.xxx.xxx.xxx xxx.xxx.xxx.xxx xxx.xxx.xxx.xxx MAC: xx: xx: xx: xx: xx: xx SIP/PORT---------
xxx.xxx.xxx.xxx xxxx ATTEND: M2(F1~F4) AUTO TNA: YES LANGUAGE: English SHOW ID: YES LOGO USE: NO UID LEN:4 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 37 DATE: YYMMDD LOG SAVE: YES IMG SAVE:NO SHOW TO: x PING TO: x NET TO: x:
INT DEVICE CARD TYPE: RF/SC CARD FMT: STD FP1:1:x FP1: N:x LFD: xx AUTH TIME:
BEEP VOL:
VOICE VOL:
BLE Name/MAC----
XXXXXXX (BLE Name) XXXXXXXXXXXXXXXXX TAMPER:ALARM EXT DEVICE LOCK1----------------------
TYPE: STRIKE/OK OUT: N/O OPEN: 3000ms LOCK2 -------------------
TYPE: NONE OUT: N/O OPEN: 3000ms DOOR WARN: 0sec FORCE OPEN:NO RS485: LC010 RS485 ID: xxx WIEGAND----------------
IN/OUT :34B/34B SITECODE: xxx SEND:USERID LOCK1: HIGH LOCK2: HIGH DM0: HIGH DM1: HIGH DM2: HIGH W0IN: HIGH W1IN: HIGH INSIDE: HIGH TAMPER SW:HIGH HW FW Card BLE I/O PORT VERSION 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 38 RECOVERY INITIALIZE SELF TEST SN(Serial Number) CONFIG LOG DB FACTORY INT DEVICE EXT DEVICE LOG EXPORT USER EXPORT USER IMPORT FW UPDATE BACKUP REBOOT VOICE CARD FP SENSOR CAMERA LED DOORLOCK SENSOR IN 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 39 3.6. USER 3.6.1. Menu Configuration USER menu has the feature as follows. Category ADD AUTO ADD MODIFY Explanation Use to add user and admin with various certification conditions. Use to add Card or Fingerprint user automatically. Use to add certification conditions, card or fingerprint of registered user. Use to delete a registered particular user. Use to delete all registered users. DELETE DELETE ALL 3.6.2. ADD 3.6.2.1. USER TYPE If you press ADD in the menu, the screen asking the user type is displayed as follow. USER TYPE USER Explanation Only available for authentication No Authorization to access menu When selecting user, the screen is displayed as follow. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 40 ADMIN Available to add and delete user. Available to access menu and modify it. When selecting the administrator, the screen is displayed as follows. 3.6.2.2. AUTH TYPE There are FP(Fingerprint), Card, and MCARD (Mobile card) in the menu. But MCARD can only provide the check state, and do not provide checking or unchecking. For checking or unchecking with MCARD, it is only available via Server and Admin App. There are AND and OR in authentication conditions. In AND, all authentication conditions should be satisfactory and then authentication succeeds. In OR, one of authentication conditions should be satisfactory and authentication succeeds. FP:0 FP is abbreviation of Finger Print. 0 means the registered FP number. (1FP means 2 fingerprints) CD:0 CD is abbreviation of CARD. 0 means the registered CARD number. Maximum card number is 1.
(U) Means your Registration Authority is general user(USER).
(A) Means your Registration Authority is administrator (ADMIN).
[FR Authentication]
[Card Authentication]
[FP or Card Authentication]
[FP and Card Authentication]
12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 41 3.6.2.3. INPUT FP Input the same fingerprint twice when you check the Fingerprint as authentication type. If you want to add only one fingerprint, select 1. NO. If you input the fingerprint second times and they are normal, INPUT OK is displayed. If you want to add more fingerprints, select 2. YES. One user can register 20 people for maximum. 3.6.2.4. INPUT CARD When you check Card as AUTH TYPE, you will follow steps as below. If you input CARD on Waiting state, registration completes and INPUT OK screen is displayed. EM CARD ex) Card No.(5byte): 08h 01h 16h 1Dh D6h Card Format Card No. Display Method Standard 02207638
(16001DD6)
(3+5)digits Decimal
[022(16h)+07638(1DD6h)]
SC CARD ex) Card No.(4byte): 52h 9Dh 06h E3h Card Format Card No. Display Method Standard 529D06E3 8digits Hex 3.6.3. AUTO ADD AUTO ADD is used when you want to register general users (not admin user) consecutively with card or fingerprint. If you select FP, it adds users by increasing ID consecutively only with fingerprint. If you select CARD, it adds users by increasing ID consecutively only with card. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 42 3.6.3.1. AUTO ADD 1. FP This is the menu when registering the users continuously only by fingerprint. Input fingerprint in twice and then the registration succeeded. If you want to add more users, select 2. YES, and continue the registration. User ID increases automatically. 3.6.3.2. AUTO ADD This is the menu when registering the users continuously only by card. After inputting the card, INPUT OK is displayed on the screen. If you want to add the other user, select 2. YES, and register the user. User IDs increases automatically. 3.6.4. MODIFY It is used when modifying the authentication type of the registered user. In authentication type, authentication type (fingerprint, card) and authentication condition
(AND, OR) can be changed. If the modification type is modified, authentication information about the authentication type can be input. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 43 3.6.5. DELETE It is used when deleting the registered users. 3.6.6. DELETE ALL It is used when deleting all the registered users. It should be careful when trying to delete, because all the users (general user, administrator) are deleted. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 44 3.7. Network Menu 3.7.1. Menu Configuration Network menu has the following features. Category Explanation Remarks NO USE USE Operation Mode Standalone Network Mode Network not used AUTH MODE TERMINAL ID TERMINAL SERVER Standalone Network mode Explanation This is the operation mode independently without server and communication. The administrator can control all the functions of the terminal. Authentication log is saved in the terminal but is not sent to server. After converting Standalone mode into Network mode and accessing in server, the authentication log saved internally is sent to sever. If you want to see the authentication log data in Standalone mode, move RECOVERY > BACKUP > LOG EXPORT from main menu, download it in USB through UDL module and check it by ACM Pro program. This is the operation mode by communicating with the server and it can control the functions of the terminal by the remote-control. Depending on the authentication mode, the order of authentication can be different.
(Authentication order about whether trying to authenticate in the terminal or the server first) Authentication log is sent to the server if the network is connected regardless of authentication mode. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 45 3.7.2. AUTH Mode Authentication mode means the authentication priority to determine whether authentication processing is done in the terminal or the server when user-authentication. It is a valid setting only when using the network. All authentication log is sent to server through the network. AUTH MODE Server/Terminal Terminal/Server Server Terminal Explanation Server Terminal After trying to do server authentication at first, terminal authentication is processed. Terminal Server After trying to do terminal authentication at first, server authentication is processed. Server only Authentication is processed only in server. Terminal only Authentication is processed only in terminal. Even if it is Terminal Only, authentication log is sent to server. In Server Only mode, if the network is disconnected, all the authentication is processed in fail. If the mode is not Server Only (Server/Terminal, Terminal/Server, Terminal) and the network is disconnected, authentication is processed in the base of DB in the terminal. 3.7.3. Terminal ID Terminal ID is a valid information only when using the network, and it can be set in the range of 1~200. If a user registered in the terminal exist, you cant change the Terminal ID. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 46 3.7.4. Terminal It is used when setting the network information in the terminal. Network setting in the terminal can be set in Static IP and DHCP. STATIC: Set the value as a user wants. DHCP: Allocated flexibly. (It can be operated normally when using the router supporting DHCP.) If STATIC is used, it is used when setting IP, Subnet mark and Gateway address of the terminal. The following is the default setting value. Category Terminal IP SUBNET MASK GATEWAY 192.168.0.3 255.255.255.0 192.168.0.1 Default Setting Value It can set the address value as follows. Function Key Function Explanation Increase the setting value Decrease the setting value Move to left Move to right Save the setting value F1 F3 F2 F4 F4 Long 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 47 3.7.5. Server When the terminal accesses in server through the network, set the information. Default setting value is as follows. Category Server IP Port number 192.168.0.2 7332 Default Setting Value 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 48 3.8. Option Menu 3.8.1. Menu configuration User menu has the same function as follows. Explanation Category ATTEND SCREEN SAVE TIMEOUT TYPE AUTO TNA LANGUAGE SHOW ID USER LOGO USER ID LEN DATE LOGO SAVE IMAGE SAVE RESULT NET ERROR PING NO USE / USE LOCKING 3.8.2. ATTEND TNA related menu are configured. Category TYPE AUTO TNA Explanation When Function Key is used in time and attendance option, it is used. Use to determine whether to remain Function Key or not shown in the default screen. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 49 3.8.2.1. TYPE It is used when setting ATTEND mode. If setting ATTEND mode, ATTEND mode is displayed in the screen when pressing Function Key shortly (F1~F4) in the default screen. Mode NONE F1~F2 F1~F4 F1~F49 Function Key Explanation F00 is only displayed in default screen. F1~F2 Function Key is recognized and F01, F02 are displayed in default screen. F1~F4 Function Key is recognized and, F01, F02, F03, F04 are displayed in default screen. F1~F4 Function Key is recognized and F01, F02, F03, F04, F11~F49 are displayed. Meaning ACCESS MODE CLOCK-IN MODE CLOCK-OUT MODE CHECK-OUT MODE CHECK-IN MODE EXPANDED MODE F00 F01 F02 F03 F04 F11~F49 TNA mode (F00~F49) is converted into F00 after 10 seconds if you dont use AUTO TNA. 3.8.2.2. AUTO TNA AUTO TNA is the menu to determine whether to remain continually the setting TNA mode or not. Category Explanation NO YES The TNA mode is automatically returned into F00 after 10 seconds. The TNA mode is continuously displayed. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 50 3.8.3. Screen The screen display related menu is configured. Category LANGUAGE SHOW ID USER LOGO USER ID LEN DATE Explanation Change the language which is displayed in the screen and is spoken. When authentication succeeds, you can set whether showing ID or not. You can set whether the logo image for customers is used or not in the default screen. It is used when modifying the length of users ID. It is used when modifying Year/ Month/ Day and time displayed in the default screen. 3.8.3.1. Language It is used to change the voice language and menu text displayed on the screen. Voice guidance is available in English, Korean, Indonesian, Thai, Arabic, Spanish, Portuguese, French, Russian, Farsi, Japanese, and Chinese. Language support for all menu text is in English, Korean, Indonesian, Spanish, Portuguese, French, Japanese and Chinese. Language support for some text is in Farsi, Arabic, Thai and Russian. 3.8.3.2. SHOW ID It is used to determine whether to show your ID at the time of authentication success window. Category NO USE Explanation Do not show your ID at the time of authentication success Screen Yes "****"
When authentication successes, it doesnt show users ID on the screen. For example, ****. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 51 USE When authentication successes, it shows users ID on the screen. For example, ****. 3.8.3.3. USER LOGO It is used to determine whether the displayed image shows the customers logo or not in the default screen. Category NO USE USE Explanation Use basically the provided default image Use the customers logo image To use the customers logo image, you should update the customers image through the server first and then the customers image is displayed in the default screen. When editing the customers image, it should be edited in the red box as the left picture. The full image size is 128 (W) x160 (H) pixel, and the red box image size is 102 (W) x74 (H) pixel. 128 74 52 160 102 26 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 52 3.8.3.4. USER ID LEN It is used to change the length of users ID. If changing the users ID, it should change in the absence of a DB because it affects users DB that is internally registered. The setting range can be set from 4 to 16. If a user registered in the terminal exist, you cant change the length of User ID. 3.8.3.5. DATE It is used to select the order of Year, Month and Day displayed in the default screen. YY: Year MM: Month DD: Day Through SETTING, you can set current Year, Month, Day and Time. 3.8.4. SAVE It is the menu including the function related to SAVE. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 53 3.8.4.1. LOG SAVE It is used to set whether to save the authentication log in memory or not. The default setting is YES. 3.8.4.2. IMAGE SAVE It is used to set whether to save the captured photo from camera when authentication successes or fails. The default setting is Fail. 3.8.5. TIMEOUT It is the menu that has the setting related with timeout. 3.8.5.1. RESULT It is used to set the authentication result display how long it keeps for a seconds. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 54 The setting range can be set from 0 to 5 seconds. If it set to 0, then dont display the authentication result. 3.8.5.2. NET ERROR If it does not communicate with the server over a period of time, it is used to set whether there is a network communication error. If PING doesnt come for a setting time in the server, it retries to connect the terminal. The setting range is available for 60~600 seconds. 3.8.5.3. PING It sets the cycle that terminal sets PING command to the server. The setting range is available for 30~255 seconds. 3.8.6. LOCKING Locking mode is the function that it rejects the authentication of all users until the administrator enters the menu and releases the locking mode. The default setting is NO USE. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 55 The default screen is displayed as follows when setting to use locking mode. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 56 3.9. INT DEVICE 3.9.1. Menu Configuration INT DEVICE menu has the features as follows. Explanation 1:1 LEVEL 1: N LEVEL LFD LEVEL AUTH TIME Set Beep Sound. Set Voice Sound BLE registration mode Set the alarm when opening terminal case. Category FP SENSOR BEEP VOICE BLE TAMPER 3.9.2. FP SENSOR For the fingerprint recognition, it sets for the user registration and authentication about the module installed inside. 3.9.2.1. 1:1 LEVEL It is the authentication level used when it tries 1:1 fingerprint authentication. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 57 3.9.2.2. 1: N LEVEL It is the authentication level used when it tries 1: N fingerprint authentication. 3.9.2.3. LFD LEVEL It sets LFD LEVEL to prevent the duress fingerprint. If setting LFD LEVEL higher and higher, the ability to prevent the input of duress fingerprint produced by rubber, paper, film, and silicon etc. reinforces but too dry fingerprint cannot be input well. Also the authentication speed can be slow. 3.9.2.4. AUTH TIME It means the maximum time to process 1: N authentication. If the authentication time exceeds, authentication timeout occurs. The authentication time is 2 to 10 seconds, the default is 5 seconds. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 58 3.9.3. BEEP It informs key touch, authentication success, and failure as beep and sets the beep level. The beep level is available from 0 to 3. 3.9.4. VOICE It supports the notice such as authentication success/failure and authentication retrial. It sets the authentication level. The voice level is available from 0 to 5. 3.9.5. BLE When registering the terminal in Administrators App, this menu is required. By using this menu, it can make the terminal BLE READY. Only if the terminal is BLE READY, it can perform the registration procedure of the terminal after the administrator app accesses the terminal. When pressing F3 long in the default screen of the terminal, it performs same operation with this menu. Regarding the method to register the terminal in the administrator APP, please refer 3.2 How to register the terminal in the administrator App. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 59 3.9.6. TAMPER When disassembling the terminal randomly, it sets whether to sound the alarm. If selecting 1. NO ALARM, even if disassembling the terminal, the alarm doesnt sound but icon is displayed. If selecting 2. ALARM, icon displays and the beep sounds in at regular intervals. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 60 3.10. EXT DEVICE 3.10.1. Menu Configuration EXT DEVICE has the features as follows. Explanation It sets the control device to lock through the internal relay. It sets the devices using RS485. It sets the device using WIEGAND. Category DOORLOCK RS485 WIEGAND 3.10.2. DOORLOCK It is the menu to set lock device (Strike, Motor type door lock) by using LOCK1 and LOCK2 port. 3.10.2.1. LOCK1 type Category NONE Strike/OK MOTOR1 Explanation No Use When connecting the light to mark authentication success/failure or 2. STRIKE/OK. When connecting Motor lock 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 61 3.10.2.2. LOCK1 OPEN TIME It sets the time to give the signal when LOCK 1 sets 2. STRIKE/OK. Strike type means the time from opening to locking the door after authenticating. The default value is 3 seconds and the input range is 1 to 20 seconds. 3.10.2.3. LOCK2 type NONE FAIL IND MOTOR2 When not using When connecting the light to mark authentication failure in Lock 2 When connecting motor lock 3.10.2.4. LOCK2 OPEN TIME If Lock 2 sets FAIL IND, it sets the time to give the signal. The default value is 3 seconds and the input range is 1 to 20 seconds. 3.10.2.5. OPEN ALARM When the door open time expires and the door open alarm time is exceeded, the alarm sounds. The default value is 5seconds and the input range is 0 ~ 20 seconds. If it is set to 0, it will not beep. If it is set to 1 ~ 20 seconds, it will beep. Door open time Open alarm time alarm DOOR OPEN state 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 62 3.10.2.6. DM0 DM0(Door Monitor 0) is the input port and it is used to detect the signal state of door open. 3.10.2.7. DM1 DM1(Door Monitor 1) is the input port and it is used to detect the signal state of lock. 3.10.2.8. DM2 DM2(Door Monitor 2) is the input port and it is used to detect a various of sensor and alarm. For example, if connecting with fire sensor, it should set 4. FIRE N/O or 5. FIRE N/C and it may cause fire alarm and icon in case of fire. In case of fire, the door automatically opens for safety. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 63 3.10.3. RS485 It is the setting for the device with RS485 communication to interface with external. 3.10.3.1. TYPE TYPE NONE LC010 LC015 SR100 MCP040 Explanation It doesnt use RS485. Lock Controller It controls LOCK through the other external module. Lock Controller It controls LOCK through the other external module. FP Dummy Reader When it installs the other FP dummy reader device in external and then operates, it is used. Terminal operates as the dummy reader. If Terminal is connected with MCP040 device, ult screen. If Terminal is not connected with MCP040, The authentication result is determines whether or not successful by MCP040. RS485ID uses 1~7. icon is displayed in the defa icon is displayed. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 64 3.10.3.2. DEV ID DEV ID is the ID that distinguishes devices and it can be set up 0-7 during RS484 communication. 3.10.4. WIEGAND WIEGAND supports each one of Input port and Output port. 3.10.4.1. WIE-INPUT It is used to set the input type when working with the device connected into WIEGAND input port. Explanation WIEGAND input port is not used. EM, HID26 Card Module Mifare Card Modules Use Access Manager program and set Wiegand format. Category NONE WIE26BIT WIE34BIT CUSTOM 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 65 3.10.4.2. WIE-OUTPUT Category NONE WIE26BIT WIE34BIT CUSTOM Explanation WIEGAND output port is not used. EM, HID26 Card Module Mifare Card Modules Use Access Manager program and set Wiegand format. 3.10.4.3. CUSTOM BIT LENGTH It can set BIT length as 1~128. 3.10.4.4. SITE CODE It is used to set the value of Site Code that is sent to WIEGAND output port. 3.10.4.5. SEND INFO It is used to select the transmitting data by the output port. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 66 SEND INFO Type USER ID 26 Bit 34 Bit None E.Parity(1)+ Site Code(8bit) + ID(16bit) + O.Parity(1) E.Parity(1)+ Site Code(8bit) + ID(24bit) + O.Parity(1) If the length of the User ID greater than 8, and sent in the following format without site code:
E.Parity(1)+ ID(32bit) + O.Parity(1) Card 26 Bit 34 Bit E.Parity(1) + 24bit Card Number+ O.Parity(1) E.Parity(1) + 32bit Card Number + O.Parity(1) 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 67 3.11. STATUS 3.11.1. Menu Configuration STATE menu has the following features. STATE information DB INFO NETWORK OPTION INT DEVICE EXT DEVICE I/O PORT Explanation User DB, Authentication log data The setting information related to network TNA, Screen setting, Saving, Time out, Lock mode Display the setting state related to the internal device. Display the setting state related to the external device. Display the current signal of Input / Output port that interfaces with outside. Display the version of the equipped device in the terminal. VERSION 3.11.2. DB INFO It displays Users DB information and the authentication log information. 3.11.3. NETWORK It displays the network setting value. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 68 3.11.4. OPTION It displays the option setting value. 3.11.5. INT DEVICE It displays the setting value related to the internal device. 3.11.6. EXT DEVICE It displays the setting information related to the external device. 3.11.7. I/O PORT It reflects the current I/O Port state and displays it on the screen. Output Port: LOCK1, LOCK2 Input Port: DM0~DM2, W0IN, W1IN, INSIDE Open, Tamper When the input port shorts GND, the signal modifies from HIGH to LOW. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 69 3.11.8. VERSION It displays the equipped module in the terminal and other version information. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 70 3.12. RECOVERY 3.12.1. Menu Configuration RECOVERY has the features as follows. Category INITIALIZE SELF TEST BACKUP Explanation CONFIG LOG DB FACTORY INT DEVICE EXT DEVICE LOG EXPORT USER EXPORT USER IMPORT FW UPDATE REBOOT REBOOT 3.12.2. INITIALIZE It is used to initialize CONFIG, LOG DB, and FACTORY in the terminal. 3.12.2.1. CONFIG It is used to initialize the modified setting value in the menu as the default value when shipping from factory. If a user registered in the terminal exist, you cant initialize the configuration information. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 71 3.12.2.2. LOG DB INIT It is used to delete the user authentication log saved in the terminal. 3.12.2.3. FACTORY INIT If trying FACTORY INIT, setting data, authentication log data, and user registration information are initialized as setting state when shipping from factory. It should be careful because the current data can be lost when you setting wrong. 3.12.3. SELF TEST It is used when the terminal tests the operation state about internal & external device by itself. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 72 3.12.3.1. INT DEVICE It could test VOICE, CARD, FP SENSOR, CAMERA and LED equipped internally by itself. Category Explanation Voice output test Card recognition test Fingerprint recognition test Camera equipment test LED output test VOICE CARD FP SENSOR CAMERA LED Voice Test When authentication successes, it repeats and play voice guidance. Card Test As you see below, the screen displays INPUT CARD state at first. When recognizing the card, Success screen displays and it returns INPUT CARD state again. If you want to stop testing, press F2. FP Sensor Test FP Sensor Test is used to test the operation state of FP sensor from terminal. Input your fingerprint twice, if they are same, it shows Success screen. Otherwise, if not, it shows Failure screen. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 73 Camera Test It is used to check whether the camera state is normal in the terminal to capture photos. LED Test It is used to check whether the state is normal about RED, GREEN and BLUE LED used to inform the operation state. At intervals of 2 seconds, RED, GREEN and BLUE LED changes from ON to OFF. 3.12.3.2. EXT DEVICE It can test the features related to the external device by itself. Category DOORLOCK SENSOR IN Explanation Lock1, Lock2 DM0 DM1 DM2 INSIDE OPEN TAMPER 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 74 DOORLOCK Test It is used to check the state of LOCK1, LOCK2 OPEN /CLOSE from the terminal. The procedure is as follows. SENSOR IN It is used to check the signal state about the input port. When the port shorts GND, if signal changes LOW, it is normal. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 75 3.12.4. BACKUP When the saved data from the terminal sends to USB by using UDL device or brings the data from USB memory and then applies it, it is used. It is available only when the UDL module is. UDL is the option module, so it is not basically provided. If you want to get more information about UDL module, please contact NITGEN customer service. USB memory recommends using Sandisk.(NOTICE: UDL Device is not supported for all USB memory. UDL module may not work depending on the USB memory size, manufacturer, and method.) If Terminal detect UDL Device and USB memory, If icon isnt displayed, all backup function doesnt operate. icon is displayed in the default screen. USB memory module UDL 3.12.4.1. LOG EXPORT The saved log data from terminal saves in USB memory through UDL (User Data Downloader module). Only the log data in the selected period sends to USB and saves it through UDL. The file name saved in USB memory is divided by period as follows. 1. 1Day: L1Day.NLG, 2. 1~30Day: L30Day.NLG 3. 1~90Day: L90Day.NLG 4. 1~180Day: L180Day.NLG 5. ALL: ALL.NLG 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 76 or 3.12.4.2. USER EXPORT The saved User DB from the terminal saves in USB memory through UDL. It saves as USER.NDB file. or 3.12.4.3. USER INPUT It reads the user DB from USB memory through UDL and add it in terminal user DB. If inputting user DB in the terminal, all existing user DB are deleted. If you need the existing user DB saved in the terminal, back up first and try to input the user. It opens USER.NDB file in USB memory and brings into the terminal through UDL. The user registration data that you brought is reflected in the internal DB and added. CAUTION: If you press F2 Key to stop in READ state, users loading will fail. or 3.12.4.4. FW update It is used when reading the firmware from USB memory through UDL and updating the terminal firmware. Firmware proceeds only when there is FW.NFW file name in USB memory. or 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 77 3.12.5. REBOOT It is used when rebooting the terminal. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com eNBioAccess-T2 User Guide 78 FCC Information This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions :
(1) This Device may not cause harmful interface, and
(2) This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for CLASS B digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try correct the interference by one or more of the following measures:
1.1. Reorient or relocate the receiving antenna. 1.2. Increase the separation between the equipment and receiver. 1.3. Connect the equipment into an outlet on a circuit different from that to which receiver is connected. 1.4. Consult the dealer or experienced radio/TV technician for help. WARNING Changes or modifications not expressly approved by the manufacturer could void the users authority to operate the equipment. CAUTION : Exposure to Radio Frequency Radiation. This equipment should be installed and operated with a minumum distance of 20 cm between the radiator and your body. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.com
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2019-03-04 | 2402 ~ 2480 | DTS - Digital Transmission System | Original Equipment |
2 | 13.56 ~ 13.56 | DXX - Part 15 Low Power Communication Device Transmitter |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 | Effective |
2019-03-04
|
||||
1 2 | Applicant's complete, legal business name |
UNION COMMUNITY
|
||||
1 2 | FCC Registration Number (FRN) |
0019341288
|
||||
1 2 | Physical Address |
12F, Munjeong Daemyeong Valeon bldg
|
||||
1 2 |
Seoul, N/A
|
|||||
1 2 |
South Korea
|
|||||
app s | TCB Information | |||||
1 2 | TCB Application Email Address |
t******@siemic.com
|
||||
1 2 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
1 2 |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
|||||
app s | FCC ID | |||||
1 2 | Grantee Code |
XX2
|
||||
1 2 | Equipment Product Code |
T2
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 | Name |
D******** L********
|
||||
1 2 | Telephone Number |
+82-2********
|
||||
1 2 | Fax Number |
+82-2********
|
||||
1 2 |
d******@unioncomm.co.kr
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 2 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 | Equipment Class | DTS - Digital Transmission System | ||||
1 2 | DXX - Part 15 Low Power Communication Device Transmitter | |||||
1 2 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Fingerprint Access Controller | ||||
1 2 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 | Modular Equipment Type | Does not apply | ||||
1 2 | Purpose / Application is for | Original Equipment | ||||
1 2 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | Yes | ||||
1 2 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 | Grant Comments | Power listed is the maximum conducted output power. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. | ||||
1 2 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 | Firm Name |
EMTEK (Shenzhen) Co., Ltd.
|
||||
1 2 | Name |
L******** W******
|
||||
1 2 | Telephone Number |
86 75********
|
||||
1 2 |
w******@emtek.com.cn
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | CC | 2402.00000000 | 2480.00000000 | 0.0007000 | |||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 15C | CC | 13.56000000 | 13.56000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC