VS-R20(SC & RF). User Guide Version Eng-1.00 Copyright 2000 By Union Community Co., LTD. Smart-i 2
<Revison History>
Version Date Description 1.00 2012-08-
22 Initial Release Firmware Version 10.51.00-
000.00
< Glossary >
Admin, Administrator
- As a user who can enter into the terminal menu mode, he/she can register/modify/delete terminal users and change the operating environment by changing settings.
- If there is no administrator for a terminal, anyone can change the settings, so it is recommended to register at least one administrator.
- Caution is required with registration and operation because an administrator has the right to change critical environmental settings of the fingerprint recognition unit.
Authentication Method
- RF (Card) Authentication
Function Keys
- [F1], [F2], [F3], [F4] are the function keys, and they are used to enter menu or to change modes.
/ 44-3 3 (138-050) Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr Smart-i 3 Table of Contents
<Revison History> ..................................................................................... 2
<Glossary> ........................................ ! . 1. Before use ........................................................................................... 4 1.1. Safety Precautions ..................... ! . 1.2. Terminal Description ......................................................................... 5 1.3. LED Signal during operation ................................................................ 5 1.4. Necessary Keys during operation ......................................................... 6 1.5. Voice Information during operation ....................................................... 6 1.6. Buzzer Sound during operation ............................................................ 6 2. Introduction .......................................................................................... 7 2.1. Features ........................................................................................ 7 2.2. Configuration .................................................................................. 8 2.3. Specifications ................................................................................. 9 3. Environment Settings ....................... ! . 3.1. Check items before setting the environment!
. 3.1.1. Enterning menu ..................................................................... 10 3.2. Menu Configuration ........................................................................ 10 4. How to use the terminal ....................................................................... 10 4.1. Change authentication mode ............................................................. 10 4.2. Authentication ............................................................................... 11 4.2.1. Card authentication ................................................................ 11 4.3. Control Dip Switch ......................................................................... 11
/ 44-3 3 (138-050) Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr Smart-i 4 1. Before use 1.1. Safety precautions
Warning Handling with wet hands or allowing liquid to flow into it is not advised.
-> It may cause an electric shock or damage Do not disassemble, repair, or modify the unit.
-> It may cause an electric shock, fire or damage. Do not place a fire source near the unit.
-> It may cause a fire. Keep out of reach of children.
accident or damage. It may cause an
- If the above warnings are ignored, it may result in death or serious injury.
Cautions Keep away from direct sunlight
It may cause deformation or color change. Avoid using water, benzene, thinner, or alcohol for cleaning
-> It may cause an electric shock or fire. Keep the fingerprint area clean.
It cannot read fingerprints correctly. Avoid impacts or using sharp objects on the unit.
The unit may be damaged and broken. Avoid high humidity or dust
->The unit may be damaged. Do not place a magnet close to the unit.
-> The unit may break down or malfunction. Avoid using insecticides or flammable sprays near the unit.
It may result in deformation or color change. Avoid severe temperature changes
The unit may be broken.
-- If the above cautions are ignored, it may result in property loss or human injury. Under no circumstances will Union Community be responsible for accidents or damages caused by inappropriate use of the product caused by not referring to the user manual.
/ 44-3 3 (138-050) Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr Smart-i 5 1.2. Terminal Description 1.3. LED Signal during operation Abnorm al Red ON: When authentication is failed Success Green ON: When authentication is successful State White Flickering: Waiting for a card to input ON: If is set as LED is always ON in terminal settings
/ 44-3 3 (138-050) Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr Smart-i 6 1.4. Necessary Keys during operation
[F1]~[F4]
- They are used to change authentication mode
[Hold F4
- Hold [F4] key down longer than 4 seconds down]
- It is used to enter menu 1.5. Voice information during operation Action Voice information Authentication is successful You are authorized. Authentication is failed Please try again 1.6. Buzzer sound during operation ppig ppibig Pressing a key or a reading a card Failed ppiiiick Successful When a button is pressed or a card is being read When fingerprint input is completed, allowing the user to remove his fingerprint Authentication failed or wrong user input Authentication successful or settings for the current user are completed.
/ 44-3 3 (138-050) Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr Smart-i 7 2. Introduction 2.1. Features
Quick and convenient authentication function
- Simple and quick authentication with only using a card
Card authentication method provided
- 125khz card and 13.56Mhz card supported per product
IP65 Outdoor Rating Die Cast Casing : The terminal can be installed outdoor.
Understated Design
- Simple and understated design with minimum interface reflected without LCD
- Pursuit of convenience and luxury from simplicity
Convenient Auto Sensing function
- Simple authentication process without any key input; simple fingerprint touching is sufficient.
Various and flexible access management provided
- Perfect control function provided by giving the right of access per user group
/ 44-3 3 (138-050) Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr Smart-i 8 2.2. Configuration
/ 44-3 3 (138-050) Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr Smart-i 9 2.3. Specifications Item CPU Pin Pad LED Flash Spec 32bit RISC 72MHz 4key 3 LED (Red, White, Blue), 4 LED (key_Led) Internal 256k Byte , External 8Mbyte Description ST Micro F1~F4 Nor Flash Number of enrolled users 10,000 users 50,000 Log Various languages supported (Possible to download Voice Message Buzzer Sound from PC) Possible to control volume Possible to control volume 125KHz RF Card Module 13.56MHz Smart (1 Sam Card Socket Support) 125KHz HID Card Card Internal RTC Support 6 Dip Switch
(485 ID Setting : 3pole, 485<->Wiegand In/Out change 1pole BLC015/BLC020/CP040 Select 2pole)
- If POE is supported, separate lock Controller is used
- If POE is supported, EM, Strike, Motor Lock are possible to use 1 Port 1 Port 1 Port 3 Port 12 VDC Interworking with 485 Controller Interworking with Wiegand-Type card reader Display Wiegand signal output or success/fail Debug Authentication Method RTC I/O Lock Control RS-485 Wiegand-In Wiegand-Out RS-232 Power
/ 44-3 3 (138-050) Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr Smart-i 10 3. Environment settings 3.1.Check items before setting the environment 3.1.1. Entering menu
[Hold F4 down] (Red & Green LED On) Menu Mode If you hold [F4] key down longer than 4 seconds, you can enter menu mode. When you enter menu mode, red and green LED on a terminal are on to classify menu mode. To change from menu mode to waiting authentication mode, press [F4] button, or do not press any button longer than 10 sec so that it will automatically to change to waiting authentication mode. 3.2. Menu Configuration
- [Fn~ long] means hold each function key down longer than 4 sec. Menu Mode
[F4~ long]
Enroll a user
(Card)
[F1~ long]
Flickering white LED for 5 sec Swipe a card
(Buzzing sound + blue LED light on) Enrolling a card is completed
(Buzzing sound + red LED light on) Enrolling a card is failed Delete a user
(Card)
[F3~ long]
Flickering the white LED for 5 sec Swipe a card
(Buzzer + blue LED light on) Enrolling a card is completed.
(Buzzer + red LED light on) Enrolling a card is failed. 4. How to use a terminal 4.1. Change to authentication mode Start a shift [F1], End a shift [F2], Start a break [F3], or Return from a break [F4]
is pressed to change to correct authentication mode.
/ 44-3 3 (138-050) Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr Smart-i 11 4.2. Authentication 4.2.1. Card Authentication Swipe a card on the card input area. 4.3. Control Dip Switch It has 6 switches, and they are divided in 485 ID Setting (3pole), changing 485 <->
Wiegand (1pole), and selecting BLC015/BLC020/CP040(2pole) 1 2 3 4 5 6 7 8 485 ID Setting 485 <-> Wiegand BLC015/BLC020/CP04 0 Admin Not using Functio n VS-R20 enables to change to Wiegand In mode or to Wiegand Out mode with using SW52.
(Each only supports Mode 1) Please check switch pins when using. When using Wiegand, check GND pin and DATA1, DATA0 pin (DATA1-DATA1 Connected, DATA0-DATA0 Connected)
/ 44-3 3 (138-050) Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr Smart-i 12
- 485 ID Setting (No.1,2 and 3 Switch) Function 1 0 0 0 0 1 1 1 1 2 0 0 1 1 0 0 1 1 3 0 1 0 1 0 1 0 1 ID Value 0 1 2 3 4 5 6 7
- Wiegand Setting (No.1,2 and 3 Switch) Function 1 0 1 2 0 1 3 0 1 Bits 26bit 34bit
- Changing 485 <-> Wiegand (No. 4 Switch) Function 4 1 0 Mode Weigand RS485
- Changing BLC015/BLC020/CP040 (No. 5 and 6 Switch) Function 5 0 0 1 1
- Changing admin (NO.7 Switch) 6 0 1 0 1 Equipment to use BLC015 BLC020 CP040 Not using Function 8 1 0 Function Use admin Not using admin
/ 44-3 3 (138-050) Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr Smart-i 13
* NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USERS AUTHORITY TO OPERATE THE EQUIPMENT.
/ 44-3 3 (138-050) Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.kr