all | frequencies |
|
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|---|
manual | photos | labels |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 2 3 4 5 |
|
User Manual | Users Manual | 1.92 MiB | July 22 2019 | |||
1 2 3 4 5 |
|
Internal Photos | Internal Photos | 1.15 MiB | July 22 2019 | |||
1 2 3 4 5 |
|
External photos | External Photos | 566.32 KiB | July 22 2019 | |||
1 2 3 4 5 |
|
Label | ID Label/Location Info | 170.62 KiB | July 22 2019 | |||
1 2 3 4 5 |
|
Label and location | ID Label/Location Info | 349.64 KiB | July 22 2019 | |||
1 2 3 4 5 | Block Diagram | Block Diagram | July 22 2019 | confidential | ||||
1 2 3 4 5 |
|
FCC Short Long Term Confidentiality Request Rev4.1 | Cover Letter(s) | 70.42 KiB | July 22 2019 | |||
1 2 3 4 5 |
|
Letter of Authorization Rev 2.0 | Cover Letter(s) | 45.67 KiB | July 22 2019 | |||
1 2 3 4 5 |
|
MTi190611E072-FCC PART 15.225 | Test Report | 796.83 KiB | July 22 2019 | |||
1 2 3 4 5 | Operation Description | Operational Description | July 22 2019 | confidential | ||||
1 2 3 4 5 | SCH | Schematics | July 22 2019 | confidential | ||||
1 2 3 4 5 |
|
Test Setup Photos | Test Setup Photos | 235.12 KiB | July 22 2019 | |||
1 2 3 4 5 | External Photos | July 22 2019 | ||||||
1 2 3 4 5 | Cover Letter(s) | July 22 2019 | ||||||
1 2 3 4 5 | Internal Photos | July 22 2019 | ||||||
1 2 3 4 5 | Test Report | July 22 2019 | ||||||
1 2 3 4 5 | Test Report | July 22 2019 | ||||||
1 2 3 4 5 | Test Report | July 22 2019 | ||||||
1 2 3 4 5 | RF Exposure Info | July 22 2019 | ||||||
1 2 3 4 5 | Test Setup Photos | July 22 2019 | ||||||
1 2 3 4 5 | Test Setup Photos | July 22 2019 | ||||||
1 2 3 4 5 |
|
MTi190611E068-FCC PART 247-2.4G WIFI | Test Report | 3.92 MiB | July 22 2019 | |||
1 2 3 4 5 |
|
SAR Test Setup Pho tos | Test Setup Photos | 404.48 KiB | July 22 2019 | |||
1 2 3 4 5 |
|
SCS-F190-WIFI-Channel-12-and-13-nbsp-Declaration-Letter-Ver-2.0 | Test Report | 395.95 KiB | July 22 2019 | |||
1 2 3 4 5 |
|
SZAWW190510002-01 Ubio tablet 5 FCC ID Report SAR | Test Report | 5.52 MiB | July 22 2019 | |||
1 2 3 4 5 | Cover Letter(s) | July 22 2019 | ||||||
1 2 3 4 5 | ID Label/Location Info | July 22 2019 | ||||||
1 2 3 4 5 | Test Report | July 22 2019 | ||||||
1 2 3 4 5 | Test Setup Photos | July 22 2019 | ||||||
1 2 3 4 5 | Test Setup Photos | July 22 2019 | ||||||
1 2 3 4 5 | ID Label/Location Info | July 22 2019 | ||||||
1 2 3 4 5 | Test Report | July 22 2019 |
1 2 3 4 5 | User Manual | Users Manual | 1.92 MiB | July 22 2019 |
Catalog 3.1 Key function ................................................................................................................... 6 3.2 Start up and shut down ............................................................................................... 6 3.3 Screen opening and closing ....................................................................................... 7 3.9 Use skill ..................................................................................................................... 14 4 Basic Settings ....................................................................................................................... 14 4.2 Bluetooth ..................................................................................................................... 15 4.3 SIM card ......................................................................................................................... 16 4.12 Users ............................................................................................................................. 24 4.13 Security ....................................................................................................................... 24 4.16 Date and Time ............................................................................................................. 26 5 Multimedia ......................................................................................................................... 29 5.1 music ............................................................................................................................... 29 5.2 video ............................................................................................................................... 30 5.4 camera ........................................................................................................................... 32 5.5 radio station ............................................................................................................... 33 6 Communication function ..................................................................................................... 34 6.1 Telephone ....................................................................................................................... 34 6.2 SMS ................................................................................................................................. 35 6.3 Address book ............................................................................................................... 35 7 Internet ................................................................................................................................... 36 7.1 Browsers ....................................................................................................................... 36 7.2 e - mail ....................................................................................................................... 36 8 Fingerprint ....................................................................................................................... 38 9 Other Applications ................................................................................................................. 39 9.1 calculator ..................................................................................................................... 39 9.2 file manager ................................................................................................................. 39 9.3 Recorder ......................................................................................................................... 41 10 Installation of the program ............................................................................................. 42 10.1 Installation ............................................................................................................... 42 10.2 Unload ........................................................................................................................... 42 10.3 Renewal approach ....................................................................................................... 42 11 Difficult and troubleshooting ......................................................................................... 43 1 1.1 Thanks 1 Introduction Thank you very much for choosing this product.BH502. It is a 5 inch mobile terminal intelligent machine. The main chip is MTK6735. This chip adopts Cortex-A53*4 architecture, the main frequency 1.3GHz, based on Android6.0 or above operation system, it can expand the third party application easily. The built-in optical fingerprint, and one dimensional (2D, optional), 4G/3G, WIFI, BT, GPS, NFC, voice calls and other functions, to achieve the fingerprint reading / validation / comparison function, quickly confirm the identity and online payment; MA (Er Weima) built in one-dimensional scanning function, can be effective for one-dimensional (Mary Er Weima) scanning recognition, bar code of goods or other forms of goods quick recognition; wireless communication and wireless network function, built-in high precision of surfing the Internet whenever and wherever possible; GPS module can be loaded through the navigation map software; built-in NFC function, support 13.56MHz core Close range non-contact recognition; built-in camera and photography. This manual introduces the various functions, skills and matters needing attention of the mobile terminal intelligent machine. Please read the manual carefully before using the mobile terminal intelligent machine. 1.2 Matters of attention Maintenance and care Please keep the equipment dry. Please don't let the device, battery, charger contact with water and water vapor, or use wet hand to operate equipment or charger, so as not to cause short circuit of equipment, and people will be electrifying because of corrosion failure. Do not cause the equipment, battery and charger to be strongly impacted or vibrate, so as to avoid the failure of equipment, batteries and chargers. Do not place the equipment, batteries and chargers in high or low temperature areas, otherwise the equipment, battery and charger may be caused by failure. Do not hit, throw, needled the mobile terminal smart machine and avoid falling, squeezing, and bending the machine. Please do not dismantle the equipment and accessories without authorization, otherwise the equipment and accessories will not be within the warranty of the company. 2 1.3 Safety instructions Before using the mobile terminal intelligent machine, please read the information in this section, and let your children understand this information. For more detailed information, please refer to the safety instructions and matters needing attention. Do not use a mobile terminal smart machine in driving the car, so as not to prevent safe driving. In the medical site, please comply with the regulations or regulations. Close the mobile terminal smart machine in the area close to the medical equipment. Please close the mobile terminal smart machine or open the aircraft mode when boarding, so as to prevent the radio signal from interfering with the aircraft control signal. Please close the mobile terminal smart machine or open the aircraft mode when boarding, so as to prevent the radio signal from interfering with the aircraft control signal. Close the mobile terminal smart machine in the vicinity of a high precision electronic device, otherwise it may cause a failure of the electronic device. Please do not dismantle the mobile terminal smart machine and accessories without authorization. Only the authorized organization can repair the machine. Please move the mobile terminal smart machine away from the magnetic device, and the radiation of the mobile terminal smart machine will erase the information stored on the magnetic device. Do not use a mobile terminal smart machine at a high temperature, where there is a flammable gas (such as a gas station). Please put the mobile terminal smart machine and accessories in a place where children can't touch them. Do not let children use it without supervision. When using this mobile terminal, please abide by the relevant laws and regulations, and respect the privacy and legal rights of other people. Please strictly observe the instructions in this manual when using the USB data line, otherwise you may damage your mobile terminal smart machine or personal computer. Do not use the mobile terminal smart machine in the wet environment such as the bathroom, and avoid the liquid soaked or flushed by liquid. 3 2 Mobile terminal smart machine introduction 2.1 Introduction of mobile terminal intelligent machine accessories Container loading list Your mobile terminal package contains the following items:
Mobile terminal smart machine AC adapter USB connection line earphone leather sheath user's manual Three package vouchers work certificate;product qualification certificate 2.2 The use and preparation of mobile terminal smart machine Battery charge The battery is first charged before the first mobile terminal smart machine is used. Use the power adapter to charge the mobile terminal smart machine. 4 2.3 Mobile terminal intelligent machine state and notification Notification diagram When your notification panel when prompted, please click on the column frame and hand slide on the screen to open the notification list. Click to view options, see detailed information. After you can click on the message box to slide up to close the window. The following information is the status bar icon graphic:
New Emails USB Connection return key View the use of history battery capacity Airplane mode SIM card state loading Home Key WIFIThe service is connected and the network is available Notification panel The notification will report the receipt of new mail, open WIFI and the ongoing activities, and you can open the notification panel to see the specific information. Opening notification panel When a new notification is shown in the notification bar, click the notice board to open the notice panel. 5 3 Fast Introduction 3.1 Key function Key function description:
Power key (power) Short dormancy / wake-up function, long press function Volume + key (up) Volume Up Volume key (down) Reduction key (Reset) Reduction key (Reset) Reset the shutdown HOME keyhome Click at any interface to return to the main interface return key back Any interface click this button to return to the upper level directory Setting key Click, short press the history of the display user 3.2 Start up and shut down start up When the POWER key is 3 seconds long, you can see the boot screen. After the system is opened, enter the screen lock state, please unlock. Shut down 1 When the POWER key is long, the shutdown option will be popped. 2 The shutdown options include mute mode, flight mode, restart and shutdown. 3 Turn off the machine. 4 When the machine is dead or inoperable, press the Reset key to turn off the machine. 6 3.3 Screen opening and closing The screen will be closed automatically when the screen is idle 1. When the screen is idle for a period of time, the screen will be automatically closed to save battery power. 2. When the screen is open, press the POWER key, and the screen can be shut down immediately. Screen off state then start up If the screen is in the closed state, you can click on the POWER key to open the screen. After opening, it will enter the lock state. Click on the small lock on the screen, appear as shown in Figure 3.1, slide upward, explain the screen just unlock. Figure 3.1 7 3.4 Use of touch screen Operation mode in mobile terminal smart machine There are many ways to browse the main screens, menus, and applications on your mobile terminal smart machine. Select When you want to use a screen keyboard, you want to select an application and other items on the home page interface, just use your finger touch point. press on The option to open a project (such as a text box or a link in a web page), or a shortcut on the home page interface Mode and main program menu move, as long as you hold the project. Fast sliding or sliding Fast sliding or slipping indicates a quick vertical or horizontal drag of a finger on a picture. Drag Before you start dragging, you must hold the finger with a certain pressure until you reach the desired position.You can't loosen your fingers before you set it up. Revolve For most of the pictures, as long as the lateral movement of the mobile terminal intelligent machine can automatically turn the screen direction from side to side, for example, input text, music interface and so on. 8 3.5 Home page interface The home page interface, like Figure 3.2, is in the blank of the main screen, and you can use the application, shortcut, and custom wallpaper for your homepage. Notification Bar prompt message Pool power Time search retur n Home key Figure 3.2 Short press recently used view 9 Extensible main page interface The homepage interface will extend to the outside of the screen width, in order to provide more space for a shortcut, so you can place new gadgets. Press the home interface blank, and then quickly with a finger sliding around to jump to extend to the outside of the screen left or right. There are more than 2 home interface extension screen as shown in figure 3-2.1.. Figure 3-2.1 Fast icon management for desktop applications The operation steps are as follows:
1.Put together an icon, drag it to an icon and superimpose a number of icons. 2.Then click on the icons that stack a lot of shortcuts, and you can expand all the application icons that you overlay before. Delete the icons on the desktop 1. The icons to be deleted are displayed on the top of the screen. Icon. 2.Drag the icon to the top of the delete icon, and when the icon is red, the pine hand can be deleted. Replace the desktop wallpaper 1.On the home page, the wallpaper can be set up when the window is popped ou at a blank of the main screen. 2.Select the picture library or the wallpaper library to select the picture. 10 3.6 Access applications Click in figure 3. 2 Button, enter the main menu interface like figure 3.3;
select the application to be accessed. Figure 3.3 3.7 USB connection USB connection settings Before transferring the file, you must first set up your USB connection settings for your mobile terminal smart machine:
1. Use the USB transmission line to connect the mobile terminal smart machine to the computer, the notification bar will appear notification. 2. Open the notice panel, how to open the panel, please check the 2.3 chapter of the mobile terminal smart machine status and notification. 3. In the notification panel, click the USB connection, and then click the transfer file (Figure 3.4). 11 Figure 3.4 Copy the file to the storage card 1. Use USB cable to connect the mobile terminal smart machine to the computer. 2. After setting up the USB connection, the connection is successfully connected with the computer. 3. Open your computer on my computer and look at the content of "X". 4. Find the file you want to copy and copy it to "X". 5. After the copy is finished, it can be pulled out directly. 3.8 Input text Use the on-screen keyboard When you start a program or select a text edit box that needs to enter a text or number, a screen keyboard appears. The keyboard has the following input method:
1. Android keyboard 2. Google Pinyin Select the input method you want to use 1.Click to set the application. 2.Select the language and the input method. 3.In the text setting area, all the installed input methods for your mobile terminal 4.Hook up after you need the input method. 12 Use and switch input method 1 2 3 4 5 3 Figure 3.5 Switch input case Switch text input mode Point selection can be inserted into space Point selection input can be executed Delete the characters on the left of the cursor. Click and hold down all the characters on the left of the cursor 13 3.9 Use skill Entry into the window widget interface In the application on the screen above the "widget" or on the screen with the left hand row will switch to the widget interface. Long press any widget can generate a shortcut on the desktop, behind the shortcut icon on the desktop, you can quickly enter the corresponding application. Create an application shortcut icon on the desktop In the application or the widget interface, press any icon will automatically switch to the desktop icon, hold not to put, can be placed anywhere on the desktop. Hint: the system may ask you to make more choices before activating the widget. If you drag and drop the target location without space, the widget will not be added to the main screen. 4 Basic Settings 4.1 Wireless and network Building a WiFi connection 1. Select the application program at the main menu interface 2. Click the WLAN, open the WiFi, and the mobile terminal intelligent opportunity automatically scan the available Wi-Fi wireless network. Figure 4.1 3. Select the Wi-Fi network that you want to connect to, if the encryption will pop up the input password window, enter the corresponding password, and click the connection. Figure 4.1 14 4.2 Bluetooth Application of Bluetooth function 1. select the application program at the main menu interface Choose Bluetooth at 2. turn on Bluetooth 3. select the right upper corner search device and the mobile terminal smart machine will automatically search the nearby Bluetooth device. For example, Figure 4.2 Figure 4.2 4. click on the Bluetooth device, will automatically pop up the matching request window, enter the corresponding password, and the corresponding match, can match the success of the match. 15 4.3 SIM card SIM settings 1. Select the application program at the main menu interface. 2. Choose SIM card. 3. Set up SIM card 1, SIM card 2 open or close. 4. Preferred SIM card settings: SIM card 1, SIM card 2., such as figure 4.3 Figure 4.3 4.4 Flow usage 1. Select the application program at the main menu interface. 2. Point out the use of flow. 3. You can see the flow state that you have used. 4. Click on the flow saving program and open all program traffic control. Figure 4.4 16 Figure 4.4 4.5 Display settings 1. select the application program at the main menu interface 2. point selection shows that the luminance is selected to adjust the brightness. For example, figure 4.5 3. Select the wallpaper at 3., and set the wallpaper. For example, figure 4.6 Figure 4.5 17 4. choose dormancy and set the dormancy time. For example, figure 4.7 Figure 4.6 Figure 4.7 5.The size of the font is selected at 5., and the font size is set. For example, figure 4.8 18 Figure 4.8 6. point selection shows the size, and the display size settings. For example, figure 4.9 Figure 4.9 19 4.6 Notification settings 1. select the setup program in the application list 2. notifications, enter notifications to all applications for application notification settings, such as figure 4.10 Figure 4.10 4.7 Sound setting 1. Select the setup program in the application list 2. Select sound and make sound settings, as in Figure 4.11 4.11 20 4.8 Management applications 1. Select the setup program in the application list 2. Select an application item that can manage and delete an installed application after entry (as in Figure 4.12) Figure 4.12 4.9 SD card and MID storage View SD cards and POS machines to store available space 1. Enter the setup application. 2. Point selection storage 3. See the space available for the SD card. 4. Look at the internal storage space of the MID machine. 21 Safe removal of SD cards 1.Click to set the application. 2.Click the store. 3.The SD card can be safely removed at this time. Figure 4.13 Note: the safe removal of SD cards can effectively protect the SD card and increase the service life of the SD card. 4.10 Battery 1. select the setup program in the list of applications. 2. Choose the battery at 3. check the battery usage and set up the power saving mode, such as figure 4.14 22 Figure 4.14 4.11 Memory 1. select the setup program in the list of applications 2. points to choose memory 3. view memory usage. For example, figure 4.15 Figure 4.15 23 4.12 Users 1. select the setup program in the list of applications. 2. Select the user a 3. select the owner and set the user name. For example, figure 4.15 Figure 4.15 4.13 Security 1. select the setup program in the list of applications. 2. It's safe at 2.. 3. point selection screen locking method, select the screen lock mode: slide, pattern, PIN code, password. For example, figure 4.16 24 Figure 4.16 4.14 Language and input method 1. select the setup program in the list of applications. 2. Select the language and input method at 2. points. 3. Select the language at 3. and set the language, such as figure 4.17 Figure 4.17 25 4.15 Backup and reset 1. select the setup program in the list of applications. 2. Select backup and reset at 3. points to restore the factory settings, to restore the factory settings, such as figure 4.18 Figure 4.18 4.16 Date and Time According to presupposition, the system automatically uses the date, time zone and time provided by the network. Manually adjust the date, time, and time zone 1 Click to set the application. 2 Scroll down the screen and select the date and time. 3 Close the automatic date and time. 4 Turn off the automatic time zone 5 Select the time zone, then select the time zone in the list. Scroll down the list to see more time zones 6 Select the set date, then select the corresponding date, month and year, select the completion of the selection. 7 Select the time to set up. Then select the corresponding hours and minutes, 26 select the completion of the selection. 8 Select the switch between 24 hour grid, 12 hour or 24 hour system. The selected time format will also be applied to the time format of the alarm clock display. Figure 4.19 Note: if you automatically use the time provided by the network, you can't set the date, time, and time zone on your own. 4.17 Barrier free 1. Click to set the application 2. There is no obstacle to the selection. 3. The related functions can be set, such as figure 4.20. Figure 4.20 27 4.18 Timing Switchgear 1. Enter the setup application 2. Point selection timing switchboard option 3. For example, figure 4.21 Figure 4.21 4.19 About mobile terminal smart machine View the state of the mobile terminal smart machine 1. Enter the setup application. 2. Select the mobile terminal smart machine. Can see the status message, model, version number, and other information. For example, figure 4.22 Figure 4.22 28 5 Multimedia 5.1 music Enter the music player: click on the music on the main menu or the desktop interface The icon goes into music playback and can be played in the list of favorite music, such as Figure 5.1:
Figure 5.1 shuffle loop album song title artist Pause / play previous Figure 5.2 next Drag play progress bar to adjust the speed of audio playback The music player button operation is shown in Figure 5.2 29 5.2 video Entering the picture: selection in the main menu Application, select the video to play to play, such as Figure 5.3 Figure 5.3 30 5.3 Library Picture library application can automatically search photos and video files stored on SD card. And picture library will classify these pictures and video files in folders. You can use picture library application to view and edit photos, take photos as desktop and view pictures. View image 1. On the main interface, select the library application. 2. Enter the library, click the folder you want to see, and look at the pictures contained in it. 3. Select the picture you want to see, and the system will automatically view it in full screen mode. 4. When you look at the picture, you can zoom in and down, put two fingers on the screen, and then separate your fingers (close your finger to show down) or double click the screen. Technique: when you browse the picture, you can slide the picture to the left or right, and switch the picture to browse. Edit and set pictures When looking at a picture in full screen mode, press the menu key to display the menu options, and you can choose the options you need to edit and set up pictures. 1. Slide Show 2. Open a picture, use the virtual button to click the menu button, and display the menu options. Prune 1. Click the menu button to display the menu options. 2. Then the cutting shears are selected, and the related areas are selected to adjust the cutters. 3. The point selection cutter is towed inside and outside the center to adjust the cutting size. 4. When you adjust the size you want, click the cut. 5. If you give up the cut, click the cancel to go back to the picture browse. Edit 1. Click the menu button to display the menu options. 2. Click on the editor. 3. The luminance, style, color, and effect settings can be performed in the pop-up options. 31 4. Click save. 5. If you give up the editor, click the return key, in the pop-up dialog box, choose not to go back to the picture browse. 5.4 camera Under the main menu or desktop, click Application icon, into the camera Camera operation button, such as figure 5.5 Video Mode Figure 5.5 32 Flash setting Look at photos and videos Photograph Photograph 5.5 radio station Main Menu Enter the radio main interface:
Reception Current frequency the On channel first SETUP MENU Collection button The next channel Figure 5.6 Search channel: click the play key in the radio, click search, the channel will be automatically searched, the search channel will be saved to the channel list Collection channel: click on the main interface You can collect this channel, which will be saved to the channel list 33 6 Communication function 6.1 Telephone 1. select dialing Application, enter the dial-up interface. 2. operate according to Figure 6.1 Dialing area dial Figure 6.1 34 6.2 SMS 1 Enter the main menu interface, choose application 2 Choose to write a new information map 6.2 Add receiver Direct number input Write message 6.3 Address book Figure 6.2 Send message Selection in the main menu interface program. For example, figure 6.4 Application, enter the address book Figure 6.4 35 7 Internet 7.1 Browsers In the case of WiFi or the normal connection of the mobile network (see Section 4.1 for wireless and network settings), click on the browser of the main menu or desktop Enter the IE interface. For example, Figure 7.1 address field Search bar Figure 7.1 7.2 e - mail The e-mail application is accompanied by the e-mail settings wizard, which can add the external POP3 or IMAP e-mail accounts of the common Web e-mail service providers, such as Yahoo, Gmail and 163, as shown in Figure 7.2. 36 Figure 7.2 a. mailbox setting 1 Select After the icon, the mailbox setting wizard will help you to set up the icon. 2 Enter the email address and password of your mailbox account. 3 Click the next button to check whether the mailbox server is available. 4 Enter the name of the account and display the name of the email, and then click the name to complete. 5 If the mailbox is available, it will automatically enter your inbox. b. delete mailbox accounts You can delete a good POP3 or IMAP mailbox account from your MID. 1. Select 2. Enter your inbox 3. Press the menu key (menu). 4. Select the settings. 5. Right drop-down select Delete account 6. The point selection can be removed. c. sends E-mail information 1 Select Show your inbox. 2 Click the inbox to automatically refresh the mail, and click to read. 37 3 Press the menu button and pop up the menu. Get into the new mail interface. 4 Point to the right upper corner 5 Enter the email address of the recipient in the addressee. 6 Input topics and information content. 7 Add attachments to the selection. 8 Select the attachments you want to send (such as pictures, video, etc.). 9 Send out e-mail after the point selection is sent. 8 Fingerprint application 8 Fingerprint Application, entry into the fingerprint application 1 Selection at the main menu test 2 Click OpenDevice to open fingerprints 3 Click Video to read the fingerprint, the fingerprint light is on, the finger is placed in the fingerprint area, and the admission is completed by clicking Stop, such as figure 8.1 Figure 8.1 38 9 Other Applications 9.1 calculator 1. Select
. 2. Enter the basic panel of the calculator. 3. Calculate the panel number or operator on the counter. Figure 9.1 9.2 file manager The file manager has to TF card files or folders to copy, cut, delete, rename and other operations, You can also share files, install APK and other functions Under the main menu or desktop, click the file management icon Enter the file manager 39 native memory External SD card Figure 9.2 a A, copy, cut, delete, rename or so on folders or files: choose a folder or file, enter the map interface with this folder or file, and you can do related operations on files or folders. Figure 9.3 40 bshare the file: select a file, press this file, select the "share" item in the pop-up list, and choose the way you share it according to the pop-up list. Figure 9.4 cInstall the APK file: select the file with the suffix.Apk in the file manager, pop up the installer, and install the third party software according to the prompt d new folder: select the directory you want to create a new folder, click right key,Select the new folder and complete the new folder according to the prompt 9.3 Recorder Under the main menu or desktop, click the recording Icon Enter the recording interface and click the recording key Start recording.Click stop Stop the recording.to hit the Play button Play the just recording. The system automatically prompts the use of this recording or give up, please manually select.Play recording: select the audio player to play the recording, first in the resource manager to select a single file according to the root directory, click to play. Figure 9.6 41 10 Installation of the program 10.1 Installation Install third party applications You can get the third party application suitable for Android system on the Internet, and you can install it on the mobile terminal intelligent machine on your own. Copy the application to the SD card and insert it into the machine. 1. Select the "file manager" application and select the application that needs to be installed. 2. Hold down the application you need to install. 3. Pop-up installation options, click to install apk. 4. Run according to the installation wizard. Note: the search for the third party programs for the system on the Internet is a.Apk suffix. 10.2 Unload uninstallation of application 1. On the home page, select the set bitmap. 2. Select the application list of all the applications installed in the system. 3. Select the APK you want to uninstall, and click the uninstall. 4. The point selection determines to complete the uninstall. 10.3 Renewal approach Update the application of the Android system Internet. 1. Download the latest application through a specified web site. 2. Download through the Android system related software forum on the 42 11 Difficult and troubleshooting 1. Mobile terminal smart machine is slow for the first time When the mobile terminal smart system is upgraded, the pre installed application needs to be installed for the first time. It will be about 2-3 minutes, and then the startup will be faster. 2. Mobile terminal smartphones cannot connect to WIFI Ensure that the wireless routing of the network services is working properly. Ensure that the distance between the mobile terminal agent and the wireless routing is maintained, and there is no wall or other barriers between them. Make sure that the input username and password are correct. 3.Mobile terminal smart machine feels hot When using multiple applications at one time, or when the screen opens up to the brightest and is charging, it may be hot. This is normal. 4. Unable to set up e - mail or register applications Make sure that your network connection is normal and can be connected to the Internet. Ensure that the email setting is correct. Make sure your system time is consistent with the local time. 5. the abnormal condition of the system can not operate normally When you install some third party applications, it may cause the system to fail to run normally. You can reset the system by pressing the reset button
(next to the power interface). 6. can't open a web page Keep the distance between the routing and mobile terminal smart machines within the effective distance Please restart WIFI and try again 7. mobile terminal smart machines sometimes run slowly This is a normal phenomenon. Please finish some tasks that are not needed at the end of advanced task management, and uninstall some third party applications to release more system resources. 43 Appendix 1 Product Parameter Classificati on content describe Basic parameter machine type BH502 CPU model MTK 8321/6737 CPU frequency 1.3GHz DDR-RAM DDR-ROM 1GB(open end 2GB) 8GB(open end 16GB) T- FLASH 32G maximum support value operating system (OS) Android 7.0 network mode GSMWCDMA,LTE data service GPRS/EDGE Support band LTE B1/B3/B7/B20/B38/B40/B41 WCDMA2100/850 GSM850/900/1800/1900;
camera Camera 5 million USB interface Micro USB USB 2.0 battery 4000mAh/6000mAh AC adapter Output voltage DC 5V, current 2A Memory card MicroSD card, maximum support for 32G home screen 5 inch high definition TFT display, resolution 720*1280 IPS GPS navigation Precise positioning of the built-in GPS satellite signal receive fingerprint Optical fingerprint NFC 13.56MHz band Bluetooth Basic function G-sensor FM sound Video playback Music game Application program Built-in Bluetooth module, supporting FTP file transmission, and sharing all kinds of interesting files at close range Achieve screen switching and support a variety of games by gravity induction FM voice, can bring you the choice of various channels anytime and anywhere Support 3GP, MP4, and other formats to support maximum resolution 1080P Built-in music player, support MP3/AAC/AMR/WAV and other formats Support the installation of the Android platform third 44 party games typewriting Android keyboard Acdsee Support JPG, BMP, PNG, GIF and other format picture browsing OFFICE software Support Office (word, excel reading and editing) to support PDF browsing FCC WARNING This device complies with part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help. Specific Absorption Rate (SAR) information:
This Mobile Phone meets the government's requirements for exposure to radio waves. The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety of all persons regardless of age or health. FCC RF Exposure Information and Statement The SAR limit of USA (FCC) is 1.6 W/kg averaged over one gram of tissue. Device types: UBio Tablet5 (FCC ID: XX2-UBIO-TABLET5) has also been tested against this SAR limit. The highest SAR value reported under this standard during product certification is 0.940W/kg when properly worn on the body .This device was tested for typical body-worn operations with the back of the handset kept 5mm from the body. To maintain compliance with FCC RF exposure requirements, use accessories that maintain a 5mm separation distance between the user's body and the back of the handset. 45 The use of belt clips, holsters and similar accessories should not contain metallic components in its assembly. The use of accessories that do not satisfy these requirements may not comply with FCC RF exposure requirements, and should be avoided. Body-worn Operation This device was tested for typical body-worn operations. To comply with RF exposure requirements, a minimum separation distance of 5mm must be maintained between the users body and the handset, including the antenna. Third-party belt-clips, holsters, and similar accessories used by this device should not contain any metallic components. Body-worn accessories that do not meet these requirements may not comply with RF exposure requirements and should be avoided. Use only the supplied or an approved antenna. Manufacturer's Name: SHENZHEN HEROFUN BIO-TECH.,LTD Sample Description:UBio Tablet5 Trade Mark: UNION COMMUNITY Model number: UBio Tablet5 Operating Temperature: 10 C to 40 C This product is a fixed location. To comply with RF exposure requirements, a minimum separation distance of 5cm must be maintained between the users body and the device, including the antenna. Use only the supplied or an approved antenna. This device in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. All essential radio test suites have been carried out. 1. CAUTION : RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS 2. The device complies with RF specifications when the device used at 5cm from your body 46 NB RF specification:
Function Operation Frequency Outputpower Max RF BT 2.4G WIFI 5G WIFI GSM 900 GSM 1800 2402-2480MHz 2412~2472 MHz 2422~2462 MHz 5150 ~5250 MHz, 5725 ~5850 MHz 880.2-914.8MHz 1710.2-1784.8MHz WCDMA Band I 1922.4-1977.6MHz WCDMA Band VIII 882.4-912.6MHz TDD Band I 1920 MHz to 1980MHz TDD Band III 1710 MHz to 1785 MHz TDD Band VII 2500 MHz to 2570 MHz FDD Band XX 832 MHz to 862 MHz TDD Band XXXVIII 2 570 MHz to 2 620 MHz TDD Band XL 2300 MHz to 2400 MHz TDD Band XLI 2496 to 2690MHz GPS FM 1.57542GHz 87.5-108MHz
(dBm) 2.560 16.02 15.83 32.48 28.99 21.87 21.52 23.04 21.77 21.50 23.79 22.07 21.70 24.86
/
/
Limit
(dBm) 20 20 23 373 243 24+1.7/-3.7 24+1.7/-3.7 232.7 232.7 232.7 232.7 232.7 232.7 232.7
/
/
47
1 2 3 4 5 | Internal Photos | Internal Photos | 1.15 MiB | July 22 2019 |
- Page 1 of 6 -
Report No.: MTi190611E067 APPENDIX 1: EUT PHOTO Photo 1 For model UBio Tablet5 Photo 2 NFC ANT Tel:(86-755)88850135 Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Web: http://www.mtitest.com Fax: (86-755) 88850136 E-mail: mti@51mti.com
- Page 2 of 6 -
Report No.: MTi190611E067 Photo 3 4G ANT Photo 4 GPS+BT+2.4G WIFI+5G WIFI ANT 2G+3G ANT Tel:(86-755)88850135 Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Web: http://www.mtitest.com Fax: (86-755) 88850136 E-mail: mti@51mti.com
- Page 3 of 6 -
Report No.: MTi190611E067 Photo 5 Photo 6 Tel:(86-755)88850135 Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Web: http://www.mtitest.com Fax: (86-755) 88850136 E-mail: mti@51mti.com
- Page 4 of 6 -
Photo 7 Report No.: MTi190611E067 Photo 8 Tel:(86-755)88850135 Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Web: http://www.mtitest.com Fax: (86-755) 88850136 E-mail: mti@51mti.com
- Page 5 of 6 -
Report No.: MTi190611E067 Photo 9 Photo 10 Tel:(86-755)88850135 Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Web: http://www.mtitest.com Fax: (86-755) 88850136 E-mail: mti@51mti.com
- Page 6 of 6 -
Report No.: MTi190611E067 Photo 11
----END OF REPORT----
Tel:(86-755)88850135 Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Web: http://www.mtitest.com Fax: (86-755) 88850136 E-mail: mti@51mti.com
1 2 3 4 5 | External photos | External Photos | 566.32 KiB | July 22 2019 |
- Page 1 of 3 -
Report No.: MTi190611E067 APPENDIX 1: EUT PHOTO Photo 1 For model UBio Tablet5 Photo 2 Tel:(86-755)88850135 Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Web: http://www.mtitest.com Fax: (86-755) 88850136 E-mail: mti@51mti.com
- Page 2 of 3 -
Report No.: MTi190611E067 Photo 3 Photo 4 Tel:(86-755)88850135 Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Web: http://www.mtitest.com Fax: (86-755) 88850136 E-mail: mti@51mti.com
- Page 3 of 3 -
Report No.: MTi190611E067 Photo 5 Photo 6
----END OF REPORT----
Tel:(86-755)88850135 Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Web: http://www.mtitest.com Fax: (86-755) 88850136 E-mail: mti@51mti.com
1 2 3 4 5 | Label | ID Label/Location Info | 170.62 KiB | July 22 2019 |
1.FCC ID:XX2-UBIO-TABLET5 2.This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 3.Model Name: UBio Tablet5 4. Rated Input: DC5V, 2.0A 5.Manufacturer information :
SHENZHEN HEROFUN BIO-TECH.,LTD Manufacturer address:
70018, 7th Floor, LaoBing Building, East Block 2,No. 3012 XingYe Road, BaoAn District, Shenzhen, China 6.Importer information : UNION COMMUNITY Importer address : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea C FE =
1 2 3 4 5 | Label and location | ID Label/Location Info | 349.64 KiB | July 22 2019 |
location information: Settings_ About phone_ Regulatory information
1 2 3 4 5 | FCC Short Long Term Confidentiality Request Rev4.1 | Cover Letter(s) | 70.42 KiB | July 22 2019 |
Address: 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, South Korea UNION COMMUNITY Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2019-7-03 Subject; Request for Confidentiality FCC ID: XX2-UBIO-TABLET5 To Whom It May Concern, Pursuant to the provisions of the Commissions rules Title 47 Sections 0.457 and 0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure External Photos Test Setup Photos Internal Photos User Manual In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR 2.803 and the importation rules in Title 47 CFR 2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s);
OR For 45 days, pursuant to Public Notice DA 04-1705. For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature:
Name: Dong Ho Lee Title: Manager Tel: +82-2-6488-3054 Email:dhlee@unioncomm.co.kr Date: 07.03.2019
1 2 3 4 5 | Letter of Authorization Rev 2.0 | Cover Letter(s) | 45.67 KiB | July 22 2019 |
UNION COMMUNITY Letter of Authorization Company: UNION COMMUNITY Address: 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, South Korea Product Name: UBio Tablet5 Model Number: UBio Tablet5 Trade mark: UNION COMMUNITY FCC Identifier: XX2-UBIO-TABLET5 We authorize MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the above named equipment. Any individual within MiCOM Labs is authorized to act on our behalf and take action on the application. We declare that MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Name: Dong Ho Lee Title: Manager Tel: +82-2-6488-3054 Email:dhlee@unioncomm.co.kr Signature of applicant:
Date: 07.03.2019
1 2 3 4 5 | Test Setup Photos | Test Setup Photos | 235.12 KiB | July 22 2019 |
Model: UBio Tablet5 Radiated emission below 1GHz Radiated emission above 1GHz Conducted emission
1 2 3 4 5 | MTi190611E068-FCC PART 247-2.4G WIFI | Test Report | 3.92 MiB | July 22 2019 |
Test Report FCCID: XX2-UBIO-TABLET5 Date of issue: June 20, 2019 Report Number:
MTi190611E068 Sample Description:
UBio Tablet5 Mod el(s):
Applicant:
Address:
UBio Tablet5 UNION COMMUNITY 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, South Korea Date of Test:
May 05, 2019 to June 20, 2019 Shenzhen Microtest Co., Ltd. http://www.mtitest.com This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen Microtest Co., Ltd. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Table of Contents
- Page 2 of 55 -
Report No.: MTi190611E068 1 GENERAL INFORMATION .......................................................................................................................................... 5 1.1 1.2 1.3 1.4 1.5 DESCRIPTION OF EUT ................................................................................................................................................... 5 OPERATION CHANNEL LIST .............................................................................................................................................. 6 TEST CHANNEL LIST ....................................................................................................................................................... 6 ANCILLARY EQUIPMENT LIST ........................................................................................................................................... 6 DESCRIPTION OF SUPPORT UNITS .................................................................................................................................... 6 SUMMARY OF TEST RESULTS .................................................................................................................................... 8 TEST FACILITIES AND ACCREDITATIONS ..................................................................................................................... 9 3.1 3.2 3.3 3.4 TEST LABORATORY ........................................................................................................................................................ 9 ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 9 MEASUREMENT UNCERTAINTY ........................................................................................................................................ 9 TEST SOFTWARE ........................................................................................................................................................... 9 EQUIPMENT LIST .................................................................................................................................................... 10 TEST RESULT ........................................................................................................................................................... 11 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.1.1 5.1.2 5.4.1 5.4.2 5.4.3 5.4.4 5.2.1 5.2.2 5.2.3 5.2.4 5.3.1 5.3.2 5.3.3 5.3.4 ANTENNA REQUIREMENT ............................................................................................................................................. 11 Standard requirement ....................................................................................................................................... 11 EUT Antenna ..................................................................................................................................................... 11 PEAK OUTPUT POWER ................................................................................................................................................. 12 Limit .................................................................................................................................................................. 12 Test setup .......................................................................................................................................................... 12 Test procedure ................................................................................................................................................... 12 Test results......................................................................................................................................................... 13 POWER SPECTRAL DENSITY ........................................................................................................................................... 14 Limit .................................................................................................................................................................. 14 Test Setup .......................................................................................................................................................... 14 Test Procedure ................................................................................................................................................... 14 Test Results ........................................................................................................................................................ 15 CONDUCTED EMISSION ................................................................................................................................................ 19 Limits ................................................................................................................................................................. 19 Test setup .......................................................................................................................................................... 19 Test procedure ................................................................................................................................................... 20 Test results......................................................................................................................................................... 21 RADIATED SPURIOUS ................................................................................................................................................... 25 Limits ................................................................................................................................................................. 25 Test setup .......................................................................................................................................................... 26 Test procedure ................................................................................................................................................... 27 Test results......................................................................................................................................................... 28 Radiation emission ....................................................................................................................................... 28 Band edge - radiated .................................................................................................................................... 32 Spurious Emission in Restricted Band 3260MHz-18000MHz ........................................................................ 34 BAND EDGE - CONDUCTED ........................................................................................................................................... 35 Limits ................................................................................................................................................................. 35 Test setup .......................................................................................................................................................... 35 Test procedure ................................................................................................................................................... 35 Test results......................................................................................................................................................... 36 6DB BANDWIDTH ....................................................................................................................................................... 40 Limit .................................................................................................................................................................. 40 Test setup .......................................................................................................................................................... 40 Test procedure ................................................................................................................................................... 40 Test results......................................................................................................................................................... 41 SPURIOUS RF CONDUCTED EMISSIONS ........................................................................................................................... 49 5.8.1 Conformance Limit ............................................................................................................................................ 49 5.8.2 Measuring Instruments ..................................................................................................................................... 49 5.5.1 5.5.2 5.5.3 5.5.4 5.5.4.1 5.5.4.2 5.5.4.3 5.7.1 5.7.2 5.7.3 5.7.4 5.6.1 5.6.2 5.6.3 5.6.4 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China 2 3 4 5
- Page 3 of 55 -
Report No.: MTi190611E068 5.8.3 5.8.4 5.8.5 Test Setup .......................................................................................................................................................... 49 Test Procedure ................................................................................................................................................... 49 Test Results ........................................................................................................................................................ 49 PHOTOGRAPHS OF THE TEST SETUP ................................................................................................................................ 53 PHOTOGRAPHS OF THE EUT ............................................................................................................................................ 55 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 4 of 55 -
Report No.: MTi190611E068 Test Result Certification Applicants name:
UNION COMMUNITY Address:
12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, South Korea Manufacture's Name:
SHENZHEN HEROFUN BIO-TECH., LTD Address:
7001B, 7th Floor, LaoBing Building, East Block 2, No. 3012 XingYe Road, BaoAn District, Shenzhen, China Product name:
UBio Tablet5 Trademark:
UNION COMMUNITY Model name:
UBio Tablet5 Standards:
Test Procedure:
FCC Part 15.247 ANSI C63.10-2013 KDB 558074 D01 DTS Meas Guidance v05r02 This device described above has been tested by Shenzhen Microtest Co., Ltd. and the test results show that the equipment under test (EUT) compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. Tested by:
Jone Lee June 20, 2019 Reviewed by:
Blue Zheng June 20, 2019 Approved by:
Smith Chen June 20, 2019 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 5 of 55 -
Report No.: MTi190611E068 1 General information 1.1 Description of EUT Product name:
UBio Tablet5 Model name:
Serial Model:
Model difference:
UBio Tablet5 N/A N/A Operation frequency:
802.11b/g/n20:2412~2462 MHz 802.11n40:2422~2452 MHz Modulation type:
IEEE 802.11g/n (HT20/HT40) : OFDM IEEE 802.11b : DSSS (DBPSK, DQPSK, CCK) Bit Rate of transmitter:
(64QAM, 16QAM, QPSK, BPSK) 802.11b:11/5.5/2/1 Mbps 802.11g:54/48/36/24/18/12/9/6Mbps 802.11n(20MHz) use 800 ns GI:
65.0/58.5/52.0/39.0/26.0/19.5/13.0/6.5 Mbps (MCS0~MCS7) 802.11n(40MHz) use 800 ns GI:
13.5/27/40.5/54/81/108/121.5/135Mbps Antenna type:
FPC Antenna Antenna gain:
0.82dBi Max. output power:
14.41dBm Power supply:
DC 3.7V from Battery or DC 5V from adapter Battery:
DC 3.7V 6000mAh Adapter information:
N/A Hardware version:
HYF_BH502G_V4.0_20190415 Software version:
SW01_H_BH502G_20190420 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 6 of 55 -
Report No.: MTi190611E068 1.2 Operation channel list Channel List for 802.11b/g/n(20) Channel Frequency (MHz) Channel Frequency (MHz) 01 02 03 04 05 06 2412 2417 2422 2427 2432 2437 07 08 09 10 11
\
2442 2447 2452 2457 2462
\
Channel List for 802.11n(40) Channel Frequency (MHz) Channel Frequency (MHz) 03 04 05 06 2422 2427 2432 2437 07 08 09
\
2442 2447 2452
\
1.3 Test channel list Channel List for 802.11b/g/n(20) Channel Low Middle High Channel Frequency (MHz) 01 06 11 2412 2437 2462 Channel List for 802.11n(40) Channel Low Middle High Channel Frequency (MHz) 03 06 09 2422 2437 2452 1.4 Ancillary equipment list Equipment Model S/N Manufacturer Certificate type Adapter
/
/
/
/
1.5 Description of Support Units The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests. Item Equipment Brand Model/Type No. Series No. Note 1
/
/
/
/
/
/
/
/
/
/
/
Note:
Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
(1)The support equipment was authorized by Declaration of Confirmation.
(2)For detachable type I/O cable should be specified the length in cm inLengthcolumn.
- Page 7 of 55 -
Report No.: MTi190611E068 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 8 of 55 -
Report No.: MTi190611E068 2 Summary of Test Results Test procedures according to the technical standards:
No. Standard Section Test Item Result Remark 1 2 3 4 5 6 7 8 15.203 Antenna Requirement 15.247 (b) Peak Output Power 15.247 (e) Power Spectral Density 15.207 Conducted Emission 15.247 (d) & 15.209 Radiated Spurious Emission 15.205 Band Edge Emission 15.247 (a)(2) 6dB Bandwidth 15.205 Spurious RF Conducted Emissions Pass Pass Pass Pass Pass Pass Pass Pass Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 9 of 55 -
Report No.: MTi190611E068 3 Test Facilities and Accreditations 3.1 Test laboratory Test Laboratory Shenzhen Microtest Co., Ltd Location No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China FCC Registration No.:
FCC Registration No.: 448573 3.2 Environmental conditions Temperature:
15C~35C Humidity 20%~75%
Atmospheric pressure 98kPa~101kPa 3.3 Measurement uncertainty The reported uncertainty of measurement y Uwhere expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2providing a level of confidence of approximately 95
%
No. Item Uncertainty 1 2 3 4 5 6 7 Conducted Emission Test RF power, conducted Spurious emissions, conducted All emissions, radiated(<1G) All emissions, radiated(>1G) Temperature Humidity 1.38dB 0.16dB 0.21dB 4.68dB 4.89dB 0.5C 2%
3.4 Test software Software Name Manufacturer RF Test System Farad Model LZ-RF Version Lz_Rf 3A3 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 10 of 55 -
Report No.: MTi190611E068 4 Equipment list Equipment Equipment Manufactur No. MTI-E001 MTI-E003 Name Spectrum Analyzer Spectrum Analyzer er Model Serial No. Calibration date Due date Agilent E4407B MY41441082 2018/09/18 2019/09/17 R&S ESCI MTI-E003 2018/09/18 2019/09/17 MTI-E004 EMI Test Receiver MTI-E006 Broadband antenna Rohde&schw arz schwarabeck MTI-E007 Horn antenna schwarabeck ESPI 1000314 2018/09/18 2019/09/17 VULB916 3 BBHA912 0D 872 2018/09/18 2019/09/17 1201 2018/09/18 2019/09/17 MTI-E014 amplifier America 8447D 3113A06150 2018/09/18 2019/09/17 MTI-E015 Immunity Signal Schloder CDG6000 Conduction 126A1343/20 15 2018/09/18 2019/09/17 MTI-E016 Generator Coupled decoupling network Schloder CND M2/M3 A2210332/20 15 2018/09/18 2019/09/17 MTI-E034 amplifier Agilent 8449B 3008A02400 2018/09/18 2019/09/17 MTI-E037 MTI-E040 Artificial power network Spectrum analyzer Schwarzbeck NSLK812 7
#841 2018/09/18 2019/09/17 Agilent N9020A MY49100060 2018/09/18 2019/09/17 MTI-E041 Signal generator Agilent N5182A MY49060455 2018/09/18 2019/09/17 MTI-E042 Analog signal generator MTI-E043 Power sensor Agilent E4421B GB40051240 2018/09/18 2019/09/17 Dare RPR3006 16I00054SN Instruments W O16 2018/09/18 2019/09/17 MTI-E047 10dB attenuator Mini-Circuits UNAT-10+
15542 2018/09/18 2019/09/17 MTI-E049 MTI-E050 spectrum analyzer PSG Signal generator Active Loop MTI-E061 Antenna 9kHz -
Schwarzbeek MTI-E052 30MHz 18-40GHz amplifier Chengdu step Micro Technology MTI-E053 15-40G Antenna Schwarzbeek MTI-E058 MTI-E081 Artificial power network EPM Series Power Meter Rohde&schw arz FSP-38 100019 2018/09/18 2019/09/17 Agilent E8257D MY46520873 2018/09/18 2019/09/17 FMZB 1519 B ZLNA-18-
40G-21 00044 2018/09/18 2019/09/17 1608001 2018/09/18 2019/09/17 BBHA917 BBHA91705 82 0 NSLK812 7 Schwarzbeck
#841 2018/09/18 2019/09/17 Agilent E4419B MY50000438 2019/4/16 2021/4/15 2018/09/18 2019/09/17 Note: the calibration interval of the above test instruments is 12 months and the calibrations are traceable to international system unit (SI). Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 11 of 55 -
Report No.: MTi190611E068 5 Test Result 5.1 Antenna requirement 5.1.1 Standard requirement 15.203 requirement: For intentional device, according to 15.203: an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device 5.1.2 EUT Antenna The EUT antenna is FPCB antenna (0.82dBi). It comply with the standard requirement. In case of replacement of broken antenna the same antenna type must be used. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 12 of 55 -
Report No.: MTi190611E068 5.2 Peak output power 5.2.1 Limit FCC Part15 Subpart C Section Test Item Limit Frequency Range
(MHz) Result 15.247(b)(3) Peak output power 5.2.2 Test setup 1 watt or 30dBm 2400-2483.5 Pass EUT Attenuato r Power meter 5.2.3 Test procedure The EUT was directly connected to the Power meter. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 13 of 55 -
Report No.: MTi190611E068 5.2.4 Test results 802.11b Test Channel Frequency
(MHz) Maximum Peak Conducted Output Power(dBm) Limit (dBm) CH01 CH06 CH11 2412 2437 2462 802.11g 14.41 13.99 14.05 30 30 30 Test Channel Frequency
(MHz) Maximum Peak Conducted Output Power(dBm) Limit (dBm) CH01 CH06 CH11 2412 2437 2462 802.11n20 12.13 13.93 14.11 30 30 30 Test Channel Frequency
(MHz) Maximum Peak Conducted Output Power(dBm) Limit (dBm) CH01 CH06 CH11 2412 2437 2462 802.11n40 12.26 12.04 11.91 30 30 30 Test Channel Frequency
(MHz) Maximum Peak Conducted Output Power(dBm) Limit (dBm) CH03 CH06 CH09 2422 2437 2452 10.15 9.82 9.89 30 30 30 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 14 of 55 -
Report No.: MTi190611E068 5.3 Power spectral density 5.3.1 Limit FCC Part15 Subpart C Section Test Item Limit 15.247(e) Power Spectral Density 8 dBm
(in any 3kHz) Frequency Range
(MHz) Result 2400-2483.5 Pass 5.3.2 Test Setup 5.3.3 Test Procedure a. The EUT tested system was configured as the statements of 2.1 unless otherwise a special operating condition is specified in the follows during the testing. b. Set analyzer center frequency to DTS channel center frequency. c. Set the span to 1.5 times the DTS channel bandwidth. d. Set the RBW 3 kHz. e. Set the VBW 3 x RBW. f. Detector = peak. g. Sweep time = auto couple. h. Trace mode = max hold. i. Allow trace to fully stabilize. j. Use the peak marker function to determine the maximum amplitude level. k. If measured value exceeds limit, reduce RBW (no less than 3 kHz) and repeat. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 15 of 55 -
Report No.: MTi190611E068 5.3.4 Test Results Frequency 2412 MHz 2437 MHz 2462 MHz 802.11b Power Density
(dBm/3kHz) Limit
(dBm/3kHz)
-8.160
-9.549
-8.397 8 8 8 Result Pass Pass Pass TX CH01 TX CH06 TX CH11 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 16 of 55 -
Report No.: MTi190611E068 802.11g Frequency 2412 MHz 2437 MHz 2462 MHz Power Density Limit
(dBm/3kHz) 8(dBm/3kHz)
-11.977
-9.562
-10.508 8 8 8 Result Pass Pass Pass TX CH01 TX CH06 TX CH11 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 17 of 55 -
Report No.: MTi190611E068 Frequency 2412 MHz 2437 MHz 2462 MHz 802.11n20 Power Density Limit
(dBm/3kHz) 8(dBm/3kHz)
-10.455
-12.408
-13.168 8 8 8 Result Pass Pass Pass TX CH01 TX CH06 TX CH11 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 18 of 55 -
Report No.: MTi190611E068 Frequency 2422 MHz 2437 MHz 2452 MHz 802.11n40 Power Density Limit
(dBm/3kHz) 8(dBm/3kHz)
-16.666
-16.286
-16.699 8 8 8 Result Pass Pass Pass TX CH03 TX CH06 TX CH9 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 19 of 55 -
Report No.: MTi190611E068 5.4 Conducted emission 5.4.1 Limits According to FCC Part 15.207(a) and KDB 174176 D01 Line Conducted FAQ v01r01. Note FREQUENCY (MHz) 0.15 -0.5 0.50 -5.0 5.0 -30.0 Class B (dBuV) Quasi-peak 66 - 56 *
56.00 60.00 Average 56 - 46 *
46.00 50.00
(1)The tighter limit applies at the band edges.
(2)The limit of " * " marked band means the limitation decreases linearly with the logarithm of the frequency in the range. 5.4.2 Test setup Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Note: 1.Support units were connected to second LISN. 2.Both of LISNs (AMN) are 80 cm from EUT and at least 80cm from other units and other metal planessupport. units.Vertical ReferenceGround Plane40cm80cmTest ReceiverHorizontal ReferenceGround PlaneEUT LISN- Page 20 of 55 -
Report No.: MTi190611E068 5.4.3 Test procedure a. EUT Operating Conditions The EUT was configured for testing in a typical fashion (as a customer would normally use it). The EUT has been programmed to continuously transmit during test. This operating condition was tested and used to collect the included data. b. The following table is the setting of the receiver Receiver Parameters Attenuation Start Frequency Stop Frequency IF Bandwidth Setting 10 dB 0.15 MHz 30 MHz 9 kHz c. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected to the power mains through a line impedance stabilization network (LISN). All other support equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling impedance for the measuring instrument. d. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and forth in the center forming a bundle 30 to 40 cm long. e. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the cable may be terminated, if required, using the correct terminating impedance. The overall length shall not exceed 1 m. f. LISN at least 80 cm from nearest part of EUT chassis. For the actual test configuration, please refer to the related Item EUT Test Photos. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China 5.4.4 Test results
- Page 21 of 55 -
Report No.: MTi190611E068 EUT UBio Tablet5 Model Name. UBio Tablet5 Temperature 26 Pressure Test Voltage 1010hPa DC 5V from adapter AC 120V/60Hz Relative Humidity 54%
Phase :
L Test Mode Normal link Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 22 of 55 -
Report No.: MTi190611E068 EUT UBio Tablet5 Model Name. UBio Tablet5 Temperature 26 Pressure Test Voltage 1010hPa DC 5V from adapter AC 120V/60Hz Relative Humidity 54%
Phase :
N Test Mode Normal link Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 23 of 55 -
Report No.: MTi190611E068 EUT UBio Tablet5 Model Name. UBio Tablet5 Temperature 26 Pressure Test Voltage 1010hPa DC 5V from adapter AC 240V/60Hz Relative Humidity 54%
Phase :
L Test Mode Normal link Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 24 of 55 -
Report No.: MTi190611E068 EUT UBio Tablet5 Model Name. UBio Tablet5 Temperature 26 Pressure Test Voltage 1010hPa DC 5V from adapter AC 240V/60Hz Relative Humidity 54%
Phase :
N Test Mode Normal link Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 25 of 55 -
Report No.: MTi190611E068 5.5 Radiated spurious 5.5.1 Limits 20dBc in any 100 kHz bandwidth outside the operating frequency band. In case the emission fall within the restricted band specified on 15.205(a), then the 15.209(a) limit in the table below has to be followed. Frequency
(MHz) 0.009~0.490 0.490~1.705 1.705~30.0 30~88 88~216 216~960 Above 960 Field Strength Measurement Distance
(micorvolts/meter)
(meters) 2400/F(KHz) 24000/F(KHz) 30 100 150 200 500 300 30 30 3 3 3 3 Spectrum Parameter Attenuation Start Frequency Stop Frequency Setting Auto 1000 MHz 10th carrier harmonic RB / VB (emission in restricted 1 MHz / 1 MHz for Peak, 1 MHz / 10Hz for band) Receiver Parameter Attenuation Average Setting Auto Start ~ Stop Frequency 9kHz~150kHz / RB 200Hz for QP Start ~ Stop Frequency 150kHz~30MHz / RB 9kHz for QP Start ~ Stop Frequency 30MHz~1000MHz / RB 120kHz for QP Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 26 of 55 -
Report No.: MTi190611E068 5.5.2 Test setup Radiated emission test-up frequency below 30MHz Radiated emission test-up frequency 30MHz~1GHz Radiated emission test-up frequency above 1GHz 3m Turntabl e EUT 1.5 m 1.5 m 4m Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Amplifie r Test Receiver 5.5.3 Test procedure
- Page 27 of 55 -
Report No.: MTi190611E068 a. EUT operating conditions. The EUT tested system was configured as the statements of 2.4 unless otherwise a special operating condition is specified in the follows during the testing. b. The measuring distance of at 3 m shall be used for measurements at frequency up to 1GHz. For frequencies above 1GHz, any suitable measuring distance may be used. c. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter open area test site. The table was rotated 360 degrees to determine the position of the highest radiation. d. The height of the equipment or of the substitution antenna shall be 0.8 m; the height of the test antenna shall vary between 1 m to 4 m. Both horizontal and vertical polarizations of the antenna are set to make the measurement. e. For emission measurements above 1 GHz, the EUT shall be placed at a height of 1.5 m above the floor on a support that is RF transparent for the frequencies of interest. Final measurements for the EUT require a measurement antenna height scan of 1 m to 4 m. f. The initial step in collecting conducted emission data is a spectrum analyzer peak detector mode pre-scanning the measurement frequency range. Significant peaks are then marked and then Quasi Peak detector mode re-measured. g. If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit, the EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement performed. h. For the actual test configuration, please refer to the related Item EUT Test photos. Note: Both horizontal and vertical antenna polarities were tested and performed pretest to three orthogonal axis. The worst case emissions were reported Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 28 of 55 -
Report No.: MTi190611E068 5.5.4 Test results 5.5.4.1 Radiation emission Below 30MHz EUT UBio Tablet5 Model Name UBio Tablet5 Relative Humidity: 52%
Phase:
Pressure 1010 hPa Test Voltage H DC 5V from adapter AC 120V/60Hz Test Mode TX Freq.
(MHz)
--
--
Reading Limit
(dBuV/m)
(dBuV/m)
--
--
--
--
Margin
(dB)
--
--
State P/F Pass Pass Note:
The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible value has no need to be reported. Distance extrapolation factor =40 log (specific distance/test distance)(dB);
Limit line = specific limits(dBuV) + distance extrapolation factor. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 29 of 55 -
Report No.: MTi190611E068 Between 30MHz 1GHz All the modulation modes have been tested, the report only shows the worst mode. The worst mode is 802.11b CH01, the worst result was report as below:
EUT Model Name Relative Humidity:
UBio Tablet5 Phase:
52%
H UBio Tablet5 Pressure 1010 hPa Test Voltage DC 5V from adapter AC 120V/60Hz Test Mode Charging+TX Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 30 of 55 -
Report No.: MTi190611E068 EUT Relative Humidity:
UBio Tablet5 Model Name UBio Tablet5 52%
Phase:
V Pressure 1010 hPa Test Voltage DC 5V from adapter AC 120V/60Hz Test Mode Charging+TX Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 31 of 55 -
Report No.: MTi190611E068 1G-25GHz Note: (1) All Readings are Peak Value (VBW=3MHz) and AV Value (VBW=10Hz).
(2) Emission Level= Antenna Factor + Cable Loss + Read Level - Preamp Factor
(3) All other emissions more than 20dB below the limit. All the modulation modes have been tested, and the worst result was report as below:
For 802.11b Frequency Read Cable Antenna Preamp Emission Limits Margin Remark Comment Level loss Factor Factor Level
(MHz)
(dBV)
(dB) dB/m
(dB)
(dBV/m)
(dBV/m)
(dB) Low Channel (2412 MHz)(802.11b)--Above 1G 4824.161 62.63 4.36 32.92 45.53 54.38 74.00
-19.62 Pk Vertical 4824.161 40.14 4.36 32.92 45.53 31.89 54.00
-22.11 AV Vertical 7236.396 60.04 5.02 37.63 45.56 57.13 74.00
-16.87 Pk Vertical 7236.396 43.93 5.02 37.63 45.56 41.02 54.00
-12.98 AV Vertical 4824.154 61.17 4.36 32.92 45.53 52.92 74.00
-21.08 Pk Horizontal 4824.154 43.07 4.36 32.92 45.53 34.82 54.00
-19.18 AV Horizontal 7236.168 62.86 5.02 37.63 45.56 59.95 74.00
-14.05 Pk Horizontal 7236.168 46.62 5.02 37.63 45.56 43.71 54.00
-10.29 AV Horizontal Middle Channel (2437 MHz)(802.11b)--Above 1G 4874.112 63.35 4.41 33.01 45.76 55.01 74.00
-18.99 Pk Vertical 4874.112 42.53 4.41 33.01 45.76 34.19 54.00
-19.81 AV Vertical 7311.247 60.15 5.02 37.68 45.59 57.26 74.00
-16.74 Pk Vertical 7311.247 46.85 5.02 37.68 45.59 43.96 54.00
-10.04 AV Vertical 4874.132 60.41 4.41 33.01 45.76 52.07 74.00
-21.93 Pk Horizontal 4874.132 48.12 4.41 33.01 45.76 39.78 54.00
-14.22 AV Horizontal 7311.085 59.30 5.02 37.68 45.59 56.41 74.00
-17.59 Pk Horizontal 7311.085 42.13 5.02 37.68 45.59 39.24 54.00
-14.76 AV Horizontal High Channel (2462 MHz)(802.11b)--Above 1G 4924.169 65.68 4.50 33.26 46.07 57.37 74.00
-16.63 Pk Vertical 4924.169 42.59 4.50 33.26 46.07 34.28 54.00
-19.72 AV Vertical 7386.215 60.68 5.02 37.78 45.77 57.71 74.00
-16.29 Pk Vertical 7386.215 44.84 5.02 37.78 45.77 41.87 54.00
-12.13 AV Vertical 4924.045 66.64 4.50 33.26 46.07 58.33 74.00
-15.67 Pk Horizontal 4924.045 47.37 4.50 33.26 46.07 39.06 54.00
-14.94 AV Horizontal 7386.132 61.09 5.02 37.78 45.77 58.12 74.00
-15.88 Pk Horizontal 7386.132 45.03 5.02 37.78 45.77 42.06 54.00
-11.94 AV Horizontal Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China 5.5.4.2 Band edge - radiated
- Page 32 of 55 -
Report No.: MTi190611E068 Note: (1) All Readings are Peak Value (VBW=3MHz) and AV Value (VBW=10Hz).
(2)Emission Level= Antenna Factor + Cable Loss + Read Level - Preamp Factor
(3) All other emissions more than 20dB below the limit. Frequency Meter Cable Antenna Preamp Emission Limits Margin Detector Comment Reading Loss Factor Factor Level
(MHz)
(dBV)
(dB) dB/m
(dB)
(dBV/m)
(dBV/m)
(dB) Type 802.11b 2310.00 55.95 2.40 27.70 40.40 45.65 2310.00 43.38 2.40 27.70 40.40 33.08 2310.00 58.89 2.40 27.70 40.40 48.59 2310.00 41.99 2.40 27.70 40.40 31.69 2390.00 57.49 2.44 28.30 40.10 48.13 2390.00 42.27 2.44 28.30 40.10 32.91 2390.00 56.25 2.44 28.30 40.10 46.89 2390.00 41.61 2.44 28.30 40.10 32.25 2483.50 58.19 2.48 28.70 39.80 49.57 2483.50 42.90 2.48 28.70 39.80 34.28 2483.50 58.87 2.48 28.70 39.80 50.25 2483.50 41.32 2.48 28.70 39.80 32.70 802.11g 2310.00 58.47 2.40 27.70 40.40 48.17 2310.00 44.23 2.40 27.70 40.40 33.93 2310.00 57.31 2.40 27.70 40.40 47.01 2310.00 42.86 2.40 27.70 40.40 32.56 2390.00 57.93 2.44 28.30 40.10 48.57 2390.00 41.90 2.44 28.30 40.10 32.54 2390.00 58.50 2.44 28.30 40.10 49.14 2390.00 43.63 2.44 28.30 40.10 34.27 2483.50 59.15 2.48 28.70 39.80 50.53 2483.50 43.87 2.48 28.70 39.80 35.25 2483.50 58.99 2.48 28.70 39.80 50.37 2483.50 42.02 2.48 28.70 39.80 33.40 74 54 74 54 74 54 74 54 74 54 74 54 74 54 74 54 74 54 74 54 74 54 74 54
-28.35
-20.92
-25.41
-22.31
-25.87
-21.09
-27.11
-21.75
-24.43
-19.72
-23.75
-21.30
-25.83
-20.07
-26.99
-21.44
-25.43
-21.46
-24.86
-19.73
-23.47
-18.75
-23.63
-20.60 Pk AV Pk AV Pk AV Pk AV Pk AV Pk AV Pk AV Pk AV Pk AV Pk AV Pk AV Pk AV Horizontal Horizontal Vertical Vertical Vertical Vertical Horizontal Horizontal Vertical Vertical Horizontal Horizontal Horizontal Horizontal Vertical Vertical Vertical Vertical Horizontal Horizontal Vertical Vertical Horizontal Horizontal Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 33 of 55 -
Report No.: MTi190611E068 2310.00 57.55 2310.00 43.42 2310.00 59.19 2310.00 42.66 2390.00 57.55 2390.00 42.25 2390.00 56.88 2390.00 42.58 2483.50 58.38 2483.50 42.89 2483.50 58.38 2483.50 42.65 2310.00 59.31 2310.00 44.30 2310.00 56.72 2310.00 43.72 2390.00 58.24 2390.00 42.68 2390.00 58.12 2390.00 43.64 2483.50 58.62 2483.50 43.90 2483.50 58.82 2483.50 42.47 802.11n20 27.70 40.40 47.25 27.70 40.40 33.12 27.70 40.40 48.89 27.70 40.40 32.36 28.30 40.10 48.19 28.30 40.10 32.89 28.30 40.10 47.52 28.30 40.10 33.22 28.70 39.80 49.76 28.70 39.80 34.27 28.70 39.80 49.76 28.70 39.80 34.03 802.11n40 27.70 40.40 49.01 27.70 40.40 34.00 27.70 40.40 46.42 27.70 40.40 33.42 28.30 40.10 48.88 28.30 40.10 33.32 28.30 40.10 48.76 28.30 40.10 34.28 28.70 39.80 50.00 28.70 39.80 35.28 28.70 39.80 50.20 28.70 39.80 33.85 2.40 2.40 2.40 2.40 2.44 2.44 2.44 2.44 2.48 2.48 2.48 2.48 2.40 2.40 2.40 2.40 2.44 2.44 2.44 2.44 2.48 2.48 2.48 2.48 74 54 74 54 74 54 74 54 74 54 74 54 74 54 74 54 74 54 74 54 74 54 74 54
-26.75
-20.88
-25.11
-21.64
-25.81
-21.11
-26.48
-20.78
-24.24
-19.73
-24.24
-19.97
-24.99
-20.00
-27.58
-20.58
-25.12
-20.68
-25.24
-19.72
-24.00
-18.72
-23.80
-20.15 Pk AV Pk AV Pk AV Pk AV Pk AV Pk AV Pk AV Pk AV Pk AV Pk AV Pk AV Pk AV Horizontal Horizontal Vertical Vertical Vertical Vertical Horizontal Horizontal Vertical Vertical Horizontal Horizontal Horizontal Horizontal Vertical Vertical Vertical Vertical Horizontal Horizontal Vertical Vertical Horizontal Horizontal Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China 5.5.4.3 Spurious Emission in Restricted Band 3260MHz-18000MHz All the modulation modes have been tested, and the worst result was report as below:
- Page 34 of 55 -
Report No.: MTi190611E068 Frequency Reading Cable Antenna Preamp Emission Limits Margin Detector Comment Level Loss Factor Factor Level
(MHz)
(dBV)
(dB) dB/m
(dB)
(dBV/m)
(dBV/m)
(dB) Type 3260 3260 3260 3260 3332 3332 3332 3332 60.80 3.27 30.02 38.05 56.04 56.33 3.27 30.02 38.05 51.57 61.70 3.27 30.02 38.05 56.94 57.13 3.27 30.02 38.05 52.37 64.50 3.31 30.00 37.91 59.90 53.43 3.31 30.00 37.91 48.83 62.92 3.31 30.00 37.91 58.32 52.73 3.31 30.00 37.91 48.13 17797 42.90 8.63 44.23 39.60 56.16 17797 32.85 8.63 44.23 39.60 46.11 17788 43.83 8.63 44.23 39.60 57.09 17788 31.95 8.63 44.23 39.60 45.21 74 54 74 54 74 54 74 54 74 54 74 54
-17.96
-2.43
-17.06
-1.63
-14.10
-5.17
-15.68
-5.87
-17.84
-7.89
-16.91
-8.79 Pk AV Pk AV Pk AV Pk AV Pk AV Pk AV Vertical Vertical Horizontal Horizontal Vertical Vertical Horizontal Horizontal Vertical Vertical Horizontal Horizontal Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 35 of 55 -
Report No.: MTi190611E068 5.6 Band edge - Conducted 5.6.1 Limits In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. If the transmitter complies with the conducted power limits based on the use of RMS averaging over a time interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 dB instead of 20 dB. Attenuation below the general limits specified in 15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in 15.205(a), must also comply with the radiated emission limits specified in 15.209(a) (see 15.205(c)). 5.6.2 Test setup 5.6.3 Test procedure a) Check the calibration of the measuring instrument using either an internal calibrator or a known signal from an external generator. b) Position the EUT without connection to measurement instrument. Turn on the EUT and connect its antenna terminal to measurement instrument via a low loss cable. Then set it to any one measured frequency within its operating range, and make sure the instrument is operated in its linear range. c) Set RBW to 100 kHz and VBW of spectrum analyzer to 300 kHz with a convenient frequency span including 100 kHz bandwidth from band edge. d) Measure the highest amplitude appearing on spectral display and set it as a reference level. Plot the graph with marking the highest point and edge frequency. e) Repeat above procedures until all measured frequencies were complete. EUT OPERATION CONDITIONS The EUT tested system was configured as the statements of 2.4 unless otherwise a special operating condition is specified in the follows during the testing. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 36 of 55 -
Report No.: MTi190611E068 5.6.4 Test results Test plots:
802.11b: Band Edge, Left Side 802.11b: Band Edge, Right Side Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 37 of 55 -
Report No.: MTi190611E068 802.11g: Band Edge, Left Side 802.11g: Band Edge, Right Side Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 38 of 55 -
Report No.: MTi190611E068 802.11n20: Band Edge, Left Side 802.11n20: Band Edge, Right Side Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 39 of 55 -
Report No.: MTi190611E068 802.11n40: Band Edge, Left Side 802.11n40: Band Edge, Right Side Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 40 of 55 -
Report No.: MTi190611E068 5.7 6dB bandwidth 5.7.1 Limit FCC Part15 Subpart C Section Test Item Limit 15.247(a)(2) Bandwidth
>= 500KHz
(6dB bandwidth) Frequency Range
(MHz) Result 2400-2483.5 Pass 5.7.2 Test setup 5.7.3 Test procedure a. Set RBW= 100 kHz. b. Set the video bandwidth (VBW) 3 x RBW. c. Detector = Peak. d. Trace mode = max hold. e. Sweep = auto couple. f. Allow the trace to stabilize. g. Measure the maximum width of the emission that is constrained by the frequencies associated with the two outermost amplitude points (upper and lower) that are attenuated by 6 dB relative to the maximum level measured in the fundamental emission. EUT Operation Conditions The EUT tested system was configured as the statements of 2.4 unless otherwise a special operating condition is specified in the follows during the testing. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China 5.7.4 Test results
- Page 41 of 55 -
Report No.: MTi190611E068 EUT Temperature UBio Tablet5 25 Model Name Relative Humidity 60%
UBio Tablet5 Pressure 1012 hPa Test Voltage Test Mode TX b Mode /CH01, CH06, CH11 DC 5V from AC Adapter 120V/60Hz Channel Low Middle High Frequency 6dB bandwidth
(MHz)
(MHz) Limit
(kHz) 2412 2437 2462 500 500 500 9.084 9.543 9.081 TX CH 01 Result Pass Pass Pass Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 42 of 55 -
Report No.: MTi190611E068 TX CH 06 TX CH 11 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 43 of 55 -
Report No.: MTi190611E068 EUT Temperature UBio Tablet5 25 Model Name Relative Humidity 60%
UBio Tablet5 Pressure 1012 hPa Test Voltage Test Mode TX g Mode /CH01, CH06, CH11 DC 5V from AC Adapter 120V/60Hz Channel Low Middle High Frequency 6dB bandwidth
(MHz)
(MHz) 2412 2437 2462 15.13 15.32 15.46 TX CH 01 Limit
(kHz) 500 500 500 Result Pass Pass Pass Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 44 of 55 -
Report No.: MTi190611E068 TX CH 06 TX CH 11 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 45 of 55 -
Report No.: MTi190611E068 EUT Temperature UBio Tablet5 25 Model Name Relative Humidity 60%
UBio Tablet5 Pressure 1012 hPa Test Voltage Test Mode TX n20 Mode /CH01, CH06, CH11 DC 5V from AC Adapter 120V/60Hz Channel Low Middle High Frequency 6dB bandwidth
(MHz)
(MHz) 2412 2437 2462 15.13 15.13 15.13 TX CH 01 Limit
(kHz) 500 500 500 Result Pass Pass Pass Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 46 of 55 -
Report No.: MTi190611E068 TX CH 06 TX CH 11 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 47 of 55 -
Report No.: MTi190611E068 EUT Temperature UBio Tablet5 25 Model Name Relative Humidity 60%
UBio Tablet5 Pressure 1012 hPa Test Voltage Test Mode TX n40 Mode /CH03, CH06, CH09 DC 5V from AC Adapter 120V/60Hz Channel Low Middle High Frequency 6dB bandwidth
(MHz)
(MHz) 2422 2437 2452 35.46 35.18 35.18 TX CH 03 Limit
(kHz) 500 500 500 Result Pass Pass Pass Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 48 of 55 -
Report No.: MTi190611E068 TX CH 06 TX CH 09 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 49 of 55 -
Report No.: MTi190611E068 5.8 Spurious RF Conducted Emissions 5.8.1 Conformance Limit Below -20dB of the highest emission level in operating band. 5.8.2 Measuring Instruments The Measuring equipment is listed in the section 6.3 of this test report. 5.8.3 Test Setup Please refer to Section 6.1 of this test report. 5.8.4 Test Procedure The Spurious RF conducted emissions compliance of RF radiated emission should be measured by following the guidance in ANSI C63.10-2013 with respect to maximizing the emission by rotating the EUT, measuring the emission while the EUT is situated in three orthogonal planes (if appropriate), adjusting the measurement antenna height and polarization etc. Set RBW=100kHz and VBW=
300KHz to measure the peak field strength, and measure frequency range from 9KHz to 26.5GHz. 5.8.5 Test Results Remark: The measurement frequency range is from 9KHz to the 10th harmonic of the fundamental frequency. The lowest, middle and highest channels are tested to verify the spurious emissions and band edge measurement data. Note1: The three modulated high, medium and low channels have been tested. The report only shows the worst mode. The worst mode is 802.11b CH01. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 50 of 55 -
Report No.: MTi190611E068 802.11b on Channel 01 802.11b on Channel 01 802.11b on Channel 01 802.11b on Channel 01 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 51 of 55 -
Report No.: MTi190611E068 802.11b on Channel 06 802.11b on Channel 06 802.11b on Channel 06 802.11b on Channel 06 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 52 of 55 -
Report No.: MTi190611E068 802.11b on Channel 11 802.11b on Channel 11 802.11b on Channel 11 802.11b on Channel 11 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photographs of the Test Setup Radiated emission
- Page 53 of 55 -
Report No.: MTi190611E068 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
- Page 54 of 55 -
Report No.: MTi190611E068 Conducted emission Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China Photographs of the EUT See the APPENDIX 1: EUT PHOTO in the report No.: MTi190611E067-1.
- Page 55 of 55 -
Report No.: MTi190611E068
----END OF REPORT----
Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: mti@51mti.com Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
1 2 3 4 5 | SCS-F190-WIFI-Channel-12-and-13-nbsp-Declaration-Letter-Ver-2.0 | Test Report | 395.95 KiB | July 22 2019 |
WIFI Channel 12 and 13 Declaration Letter Reason for Amendment Approved Date Revision History Initial Release (obsolete) Modify the select options (current) To 1.0 2.0 December 22, 2015 September 23, 2016 From Initial 1.0 SCS-F190WiFi Channel 12&13 Declaration Letter Created by William Graff Page 1 of 2 Rev.2.0 Approved by Bao-Thuong Nguyen UNION COMMUNITY WIFI Channel 12 and 13Declaration Letter We declare the equipment identified below with regards to Channel 12 and 13 capabilities for FCC ID: XX2-UBIO-TABLET5 Declaration Product hardware does not have the capability to operate on Channel 12 and 13. Product hardware has the capability to operate on Channel 12 and 13. However, these two channels will be disabled via software and will not be accessible to user. Product hardware has the capability to operate on Channel 12 and 13. However,all the operated channels cant be changed in the RF parameter via software. All channels have complied with all of the requirements sets out in FCC Part 15.247. Product hardware has the capability to operate on WiFi Channel 12 and 13, and meets the requirements of KDB 594280 D01 v02r01. Please note:
1.) By default, this device operates in a mode that is compliant with the U.S. requirements. 2.) This device will also use supplemental information such as geo-location data to determine that it is operating outside the U.S., if necessary, to change its power. Such supplemental data will be derived from the following:
Global Navigation Satellite System (GNSS)7 sensors in the device Mobile Country Code (MCC),8 or MCC with a Mobile Network code (MNC), received from a CMRS9 carrier and received directly by a receiver on the device Country information derived from multiple adjacent access points (for example using IEEE Std 802.11d provisions) may be permitted on case-by-case basis Other suitable geo-location data based on IP addresses or other reliable source. Name / Title: Dong Ho Lee/Manager Signature:
Phone: +82-2-6488-3054 Email: dhlee@unioncomm.co.kr Date: 07.15.2019 SCS-F190WiFi Channel 12&13 Declaration Letter Created by William Graff Page 2 of 2 Rev.2.0 Approved by Bao-Thuong Nguyen
1 2 3 4 5 | SZAWW190510002-01 Ubio tablet 5 FCC ID Report SAR | Test Report | 5.52 MiB | July 22 2019 |
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2019-07-22 | 13.56 ~ PowerOutput | DXX - Part 15 Low Power Communication Device Transmitter | Original Equipment |
2 | 2580 ~ PowerOutput | PCB - PCS Licensed Transmitter | ||
3 | 2412 ~ PowerOutput | DTS - Digital Transmission System | ||
4 | 5745 ~ PowerOutput | NII - Unlicensed National Information Infrastructure TX | ||
5 | 2402 ~ PowerOutput | DSS - Part 15 Spread Spectrum Transmitter |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 3 4 5 | Effective |
2019-07-22
|
||||
1 2 3 4 5 | Applicant's complete, legal business name |
UNION COMMUNITY
|
||||
1 2 3 4 5 | FCC Registration Number (FRN) |
0019341288
|
||||
1 2 3 4 5 | Physical Address |
12F, Munjeong Daemyeong Valeon bldg
|
||||
1 2 3 4 5 |
Seoul, N/A
|
|||||
1 2 3 4 5 |
South Korea
|
|||||
app s | TCB Information | |||||
1 2 3 4 5 | TCB Application Email Address |
c******@micomlabs.com
|
||||
1 2 3 4 5 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
1 2 3 4 5 |
B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
|
|||||
1 2 3 4 5 |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
|||||
app s | FCC ID | |||||
1 2 3 4 5 | Grantee Code |
XX2
|
||||
1 2 3 4 5 | Equipment Product Code |
UBIO-TABLET5
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 3 4 5 | Name |
D**** L********
|
||||
1 2 3 4 5 | Telephone Number |
+82-2********
|
||||
1 2 3 4 5 | Fax Number |
+82-2********
|
||||
1 2 3 4 5 |
d******@unioncomm.co.kr
|
|||||
app s | Technical Contact | |||||
1 2 3 4 5 | Firm Name |
UNION COMMUNITY
|
||||
1 2 3 4 5 | Physical Address |
China
|
||||
1 2 3 4 5 |
d******@unioncomm.co.kr
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 2 3 4 5 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 3 4 5 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 3 4 5 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 3 4 5 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 2 3 4 5 | PCB - PCS Licensed Transmitter | |||||
1 2 3 4 5 | DTS - Digital Transmission System | |||||
1 2 3 4 5 | NII - Unlicensed National Information Infrastructure TX | |||||
1 2 3 4 5 | DSS - Part 15 Spread Spectrum Transmitter | |||||
1 2 3 4 5 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | UBio Tablet5 | ||||
1 2 3 4 5 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 3 4 5 | Modular Equipment Type | Does not apply | ||||
1 2 3 4 5 | Purpose / Application is for | Original Equipment | ||||
1 2 3 4 5 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | Yes | ||||
1 2 3 4 5 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 3 4 5 | Grant Comments | Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory and product specific (wireless router) use conditions is 0.94W/kg and 1.29W/kg respectively. | ||||
1 2 3 4 5 | Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth, and support a 2x2 MIMO as is described in the filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 5 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory and product specific (wireless router) use conditions is 0.35W/kg and 1.29W/kg respectively. | |||||
1 2 3 4 5 | Output power listed is conducted power. | |||||
1 2 3 4 5 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 3 4 5 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 3 4 5 | Firm Name |
Shenzhen Microtest Co., Ltd.
|
||||
1 2 3 4 5 | Name |
K******** T****
|
||||
1 2 3 4 5 | Telephone Number |
+8607********
|
||||
1 2 3 4 5 |
k******@51mti.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | CC | 13.56000000 | 13.56000000 | ||||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 22H | 824.2 | 828.8 | 1.7179 | 2.5 ppm | 247KGXW | ||||||||||||||||||||||||||||||||||
2 | 2 | 22H | 824.2 | 828.8 | 0.7499 | 2.5 ppm | 300KG7W | ||||||||||||||||||||||||||||||||||
2 | 3 | 24E | 1850.2 | 1909.8 | 1.0399 | 2.5 ppm | 274KG7W | ||||||||||||||||||||||||||||||||||
2 | 4 | 24E | 1850.2 | 1909.8 | 1.5776 | 2.5 ppm | 249KGXW | ||||||||||||||||||||||||||||||||||
2 | 5 | 24E | 1852.4 | 1907.6 | 0.2432 | 2.5 ppm | 4M21F9W | ||||||||||||||||||||||||||||||||||
2 | 6 | 22H | 826.4 | 846.6 | 0.1429 | 2.5 ppm | 4M21F9W | ||||||||||||||||||||||||||||||||||
2 | 7 | 27 | 2507.5 | 2562.5 | 0.2037 | 2.5 ppm | 13M4G7D | ||||||||||||||||||||||||||||||||||
2 | 8 | 27 | 2510 | 2560 | 0.2028 | 2.5 ppm | 17M9G7D | ||||||||||||||||||||||||||||||||||
2 | 9 | 27 | 2510 | 2560 | 0.2089 | 2.5 ppm | 17M8W7D | ||||||||||||||||||||||||||||||||||
2 | 1 | 27 | 2580 | 2610 | 0.2399 | 2.5 ppm | 18M1G7D | ||||||||||||||||||||||||||||||||||
2 | 11 | 27 | 2310 | 2355 | 0.2065 | 2.5 ppm | 8M97W7D | ||||||||||||||||||||||||||||||||||
2 | 12 | 27 | 2507.5 | 2562.5 | 0.1976 | 2.5 ppm | 13M5G7D | ||||||||||||||||||||||||||||||||||
2 | 13 | 27 | 2506 | 2580 | 0.1977 | 2.5 ppm | 18M1G7D | ||||||||||||||||||||||||||||||||||
2 | 14 | 27 | 2507.5 | 2562.5 | 0.2075 | 2.5 ppm | 13M5W7D | ||||||||||||||||||||||||||||||||||
2 | 15 | 27 | 2572.5 | 2617.5 | 0.2472 | 2.5 ppm | 4M53W7D | ||||||||||||||||||||||||||||||||||
2 | 16 | 27 | 2307.5 | 2312.5 | 0.2018 | 2.5 ppm | 4M51G7D | ||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
3 | 1 | 15C | CC | 2412.00000000 | 2462.00000000 | 0.0280000 | |||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
4 | 1 | 15E | CC | 5180 | 5240 | 0.01 | |||||||||||||||||||||||||||||||||||
4 | 2 | 15E | CC | 5745 | 5825 | 0.01 | |||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
5 | 1 | 15C | CC | 2402.00000000 | 2480.00000000 | 0.0040000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC