Unitech HT580L Operation Guide Version 1.0 Unitech Part Number: 400412 1 Overview ............................................................................................................................................................ 3 1. SETTING .............................................................................................................. 4 1.1. DATE & TIME.............................................................................................................................................. 4 1.2. Device.............................................................................................................................................................. 5 1.2.1. BACKLIGHT........................................................................................................................................... 5 SCANNER .............................................................................................................................................. 5 1.2.2. 1.2.3. AUTORUN.............................................................................................................................................. 6 1.2.4. Memory ................................................................................................................................................... 6 1.3. MODEM......................................................................................................................................................... 6 1.3.1. BAR....................................................................................................................................................... 10 1.3.2. PSWD Password ............................................................................................................................. 11 1.3.3. SYS Perform Cold/Warm Start or Update F/W.................................................................................. 11 1.3.4. DIAG - Diagnostics............................................................................................................................... 12 2. COMMUNICATION..............................................................................................13 2.1. USB communication.................................................................................................................................... 13 2.2. BlueTooth communication.......................................................................................................................... 13 2.3. Communication program........................................................................................................................ 15 2.4. Modem communication........................................................................................................................... 17 3. TECHNICAL SPECIFICATION....................................................................19 Model .................................................................................................................................................................... 19 HT580L................................................................................................................................................................. 19 3.1. Pin Assignment......................................................................................................................................... 20 Unitech Part Number: 400412 2 Overview HT580L operation guide will cover more detail on F/W setting and software development tool APG580 (Application Generation for HT580L) After power on HT580LL, it will show main menu as below There are 3 options Setting , Formaching and Run APG580. HT580L V1.15 1. SETTING 2. FORMCACHING 3. RUN APG580 Unitech Part Number: 400412 3 1. Setting Setting menu do 2 major functions User mode setting and Supervisor setting. In HT580L User Guide, it already explains user mode operation. This document will also repeat it again from below section. Note : Due to no barcode scanning requirement on Setting menu, SCAN key will also be treated as ENTER key during Setting operation. So, user can use below 2 ways to select any Setting item
Press MENU key to move cursor to target item and then press SCAN(or ENTER) key
Direct press item number (without combining with ENTER) to enter setting item After pressing 1 key from main screen, there are four setting options which include the following:
1. DATE & TIME 2. DEVICE 3. MODEM 4. SUPERVISOR 1.1. DATE & TIME Press 1 (or press MENU key to move cursor to item 1) to enter DATE & TIME category so that you are able to set the correct date and time. The page will appear as it is shown below:
Press numeric keys to input correct date & time. Once complete, press [ENTER] to save the revised settings. To go back to previous menu, press [ESC]. YYYY-MM-DD 2000-01-08 HH-MM-SS 05:50:35 Unitech Part Number: 400412 4 1.2. Device Use MENU key to move cursor to one of item and then press ENTER (or SCAN key) or directly press 1 ~ 3 to select target item:
1. BACKLIGHT 2. SCANNER 3. AUTORUN 4. MEMORY 1.2.1. BACKLIGHT HT580Ls backlight can be automatically on after key pressed and it will automatically off after predefined period time if there is no more key pressed. Timeout period will be reset if any key is pressed. In HT580L, timeout period can be set to 10/20/30 or 60 seconds. Or backlight can be set as always OFF or ALWAYS on. To set up the backlight, press MENU to adjust the setting. There are below options for choice Item On 10 SECS On 20 SECS On 30 SECS On 60 SECS Always Off Description Turn on backlight after key-pressing, and then automatically turn off after 10 seconds Turn on backlight after key-pressing, and then automatically turn off after 20 seconds Turn on backlight after key-pressing, and then automatically turn off after 30 seconds Turn on backlight after key-pressing, and then automatically turn off after 60 seconds Always turn on backlight Always turn off backlight BACKLIGHT selection : ON 10 SECS/ ON 20 SECS/ ON 30 SECS/ ON 60 SECS/ Always/ OFF Selecting your preference and press [ENTER] to save the change. To go back to previous menu, press
[ESC]. 1.2.2. SCANNER ON NORMAL ON FLASH OFF SCANNER selection: ON NORMAL/ON FLASH/OFF. Press [MENU] key to select your preference and press [ENTER] (or [SCAN] key) to save the changes. To go back to the previous menu, press [ESC]. Below are explanation for those 3 options Standard operation way (one trigger on scan), scanning beam will be emitted when press SCAN key and scanning will be off when releasing SCAN key. Scanning beam will be also off when it successfully read barcode Press SCAN (and then immediately), scanner will automatically continuously emit scanning beam and off scanning beam until Enter flash mode after press SCAN key
(and then release SCAN key). User can press SCAN key again to stop Flashing. Turn off scanner. Scanning beam will not be emitted after press SCNA key Unitech Part Number: 400412 5 AUTORUN is defined to automatically run pre-define FORMCACHING or APG580 program after power on. Or setup HT580L to back to previous running point before power off. There are below 4 options for choice. Always run Formcaching from beginning after power on HT580L Always run APG580(EasyJob) from beginning after power on HT580L Back to previous running point before power off. This option is default setting. Always warm-start after power on. It will back to start menu. 1.2.3. AUTORUN Formcaching APG580 RESUME OFF 1.2.4. Memory To display total memory and free memory space. 1.3. MODEM Unitech provide modem cradle as HT580Ls accessory. So, user can get data through modem if HT580L is plug into modem cradle. In general, system administrator need to setup host PC to automatically dial to modem cradle and then issue command from host to do data communication or remote control. For such configuration, it is necessary to setup modem to automatically pick phone when host call modem. So, it provides option AUTO ANSWER to setup modem from HT580L. User can also directly call to remote host PC from modem cradle via HT580L. So, it is necessary to setup remote PCs phone number, and then dial out, and then hang up phone if user need to stop modem communication. There are below 4 options on MODEM 1.PHONE NUMBER 2.AUTO ANSWER 3.DIAL OUT 4.HANG OUT To setup remote modems phone number Send ATS0=1 [enter] to modem cradle. So, modem cradle will automatically pickup phone after one ring tone. You will get error message if HT580L is not plugged into cradle or modem cradle is power off. Dial out according Phone number setting. It will send ATDT + phone number Hang up phone (send +++ and then ATH) Unitech Part Number: 400412 6 Unitech Part Number: 400412 7 FormCaching Specification Category FIELD PROMPT DATA FIELD DEFINITION: maximum field number=8 Description set field prompting 1. set minimum field length 2. MIN/MAX and maximum field length numeric data (0~9) or alphanumeric data (20H~FCH) Range Max.16 characters 1-48 Field LENGTH Field type 3. 4. DEVICE TYPE 1.NUMERIC 2.ALPHANUM 1.KEY ONLY 2.SCAN ONLY 3.BOTH DATA RECORD DEFINITION Range 1.Append Screen 5. 2.Clear Screen Category Between Field 6. FIELD DELIMITER 1. , 2. ;
3.SPACE 4.TAB 5. FIXED LENGTH 7. RECORD DELIMITER 8. DATE STAMP FIELD 9. TIME STAMP FIELD 10. Trasn. Mode 11. FIELD DELAY 1.CR 2.LF 3.CRLF 1.NONE 2.MMDD 3.YYYYMMDD 4.DDMMYY 5.YYYYMMDD 6.DDMMYYYY 1.NONE 2.HHMM 3.HHMMSS 4.SSMMHH 1. Batch 2. Online None 3. Online Multi 0-6 input by keyboard only, bar code scanning only or both Description 1. Append Screen: Prompt will be displayed on next line according previous cursor place. If cursor is already on the last line, it will scroll one line up. 2. Clear Screen: It will clear screen and then display Assign field delimiter, Fixed Length mean to store data according maxi length setting, it will automatically append spaces to end of field data if length of input data are less than maxi. length assign record delimiter assign date stamp and specify the format of date stamp assign time stamp and specify the format of time stamp T specify time delay between each record input in second When FormCaching is enabled, a data file named FORM.DAT will be created in the HT580L. FORM.DAT stores the data as entered by the user after FormCaching is invoked. The HT580L will not allow the user to redefine the data fields in FormCaching once the FORM.DAT has been created. The file FORM.DAT must be deleted in order to implement any change in the configuration of FormCaching. Running The Resident FormCaching Application Program Enable the FormCaching, the HT580L built-in application can be ran by switching the portable terminal to the main menu of operation and selecting 2.FORMCACHING, select 2.FORMCACHING. The FormCaching application program will follow the setting (as previously defined by the user) as it displays prompts, requests input, and stores data in the FORM.DAT file. Pressing [ESC] key will abort the current record inputting action. Unitech Part Number: 400412 8 HT580L FormCaching Defaults The HT580L enables FormCaching by default, the following settings also apply:
DATA FIELD DEFINITION: field number=2 Setting Category ITEM:
Field #1 FIELD PROMPT DATA LENGTH 20 ALPHANUM DATA TYPE BOTH DEVICE TYPE QTY:
Field #2 FIELD PROMPT DATA LENGTH 8 NUMERIC DATA TYPE DEVICE TYPE KEY ONLY DATA RECORD DEFINITION Category FIELD DELIMITER RECORD FELIMITER DATE STAMP FIELD TIME STAMP FIELD FIELD DELAY Setting
, CR NONE NONE 1 Unitech Part Number: 400412 9 1.3.1. BAR This option is use to configure individual symbologies for each barcode. After enter configuration menu, the LCD will display the BARCODE Setup as shown below.
< BARCODE SETUP>
CODE 39 ON Press [MENU] key to toggle between settings. Press [SCAN] or [ENTER] key to set. Setup decoding of HT580L supported bar code symbologies Symbology Code 39 I 2 of 5 Code 32 Matrix 2 of 5 Industrial 2 of 5 Decoding Decoding Codabar Check Digit Decoding Check Digit Option ON/OFF ON/OFF ON/OFF Function Decoding full ASCII Check Digit Start/stop Character Send/No-send Decoding Check Digit First digit Last digit Decoding First digit Last digit Decoding Check Digit ON/OFF OFF/On&Not send/ON&Send SEND/NOT SEND SEND/NOT SEND ON/OFF SEND/NOT SEND SEND/NOT SEND ON/OFF ON/OFF ON/OFF ON/OFF ON / ON&Not Send / ON&SEND
/ OFF ON/OFF ON / ON&Not Send / ON&SEND
/ OFF ON/OFF SINGLE MOD 10/DOUBLE MOD 10/DOUBLE MOD 11+10 ON&Send / ON&NOT SEND ON/OFF ON / ON&Not Send / ON&SEND
/ OFF ON/OFF ON / ON&Not Send / ON&SEND
/ OFF ON/OFF Decoding ON/OFF ISBN ON/OFF ISBN Send/No-send Leading Digit Send/No-send Check Digit ON/OFF decoding SEND/NOT SEND Leading digit SEND/NOT SEND Check Digit decoding ON/OFF EXPEND to EAN-13 ON/OFF Decoding CHECK MOD Check Digit Decoding Check Digit Decoding Check Digit DIGIT Default ON OFF OFF NO SEND ON OFF SEND SEND ON SEND SEND ON OFF ON ON OFF ON OFF OFF SINGLE MOD 10 OFF OFF OFF OFF OFF ON OFF OFF Send Send ON SEND SEND ON OFF CHINA POST CHINA POST IDATA 2 of 5 CODE 11 EAN-13 EAN-8 UPC-A Unitech Part Number: 400412 10 UPC-E CODE 93 Code 128 SEND/NOT SEND SEND/NOT SEND ON/OFF ON/OFF ON/OFF ON/OFF Leading digit Check Digit decoding UPC-E0 UPC-E1 EXPEND TO UPC-
A Leading digit Check Digit decoding decoding EAN128 EAN128 CODE ID EAN128 FUNC CH NOT SEND/SEND SEND/NOT SEND SEND/NOT SEND ON/OFF ON/OFF ON/OFF ON/OFF TELPEN UK PLESSEY decoding decoding Check Digit 1.3.2. PSWD Password ON/OFF ON/OFF SEND/NOT SEND Change Supervisor password The default password is 580 1.3.3. SYS Perform Cold/Warm Start or Update F/W SEND SEND ON ON ON OFF SEND SEND OFF ON ON OFF NOT SEND ON OFF SEND 1. WARM START 2. COLD START 3. UPDATE F/W 4. UPDATE DEC There are 4 options on this item Warm Start, Cold Start, Update F/W and Update Decoder
Warm Start : warm boot HT580L
Cold Start : All of data and setting will be set to system default
Update F/W : Update F/W version. You can get the latest F/W image from supplier, F/W will be compressed as ZIP file. There are 8 files after unzip it bank0.bin ~ bank7.bin. You can use communication program to send those 8 files into HT580L and then execute this option to update F/W. Please refer to Section Communication to know more detail information for communication program. Unitech Part Number: 400412 11 1.3.4. DIAG - Diagnostics The HT580L has a built-in diagnostics program to test the terminal's hardware. The test routines are data destructive. Therefore, before running the diagnostic program, make sure you back up the data in the HT580L. Note : When a H/W or S/W service has been made on the PT630, such as maintenance, repair or upgrade, it is strongly recommended to run the diagnostic program. At the Supervisor Mode menu:
1. Press 7 (7.DIAG), then LCD will display the diagnostic menu as shown on the left. Select 1-8 to run the desired diagnostic routine 1. VER 2. SCAN 3. LCD 4. COMM 5. PWR 6.KEY 7. RTC 8.MEM
: Get F/W version for HT580L and Decoder. 1. VER 2. SCAN : test bar code input by scanning bar code labels. Press ESC key to return to the diagnostics menu.
: Darken the dots of the LCD screen and cycle power to the LCD backlight to check 3. LCD if the LCD functions OK 4. COMM : Connect test USB/RS232 communication
: Testing Battery power 5. PWR
: Test every key response 6. KEY 7. RTC
: Show Current time/date is displayed 8. MEM
: Test RAM condition Note : Please refer to Service manual for more detail information. to PCs communication testing program to Unitech Part Number: 400412 12 2. Communication 2.1. USB communication To connect HT580L to PC via USB, you need to install USB driver which will redirect data to virtual COM port. You can get USB driver from HT580L CD. Window OS will prompt new device dialog box when PC is the first time to be connected to HT580L via USB. Please re-direct driver folder to Unitechs USB driver folder and then follow its prompting to install driver. Then you can check correct COM port number from Control Panet System Hardware Device manager, then you can find correct COM number from USB Serial Port under option Connection Port(COM and LPT) In HT580L, you should change it default communication port to RS232/USB from Setting Supervisor Comm Port 2.2. BlueTooth communication To do BlueTooth communication, you should change HT580Ls port setting to BlueTooth from Setting Supervisor Comm Port In PC, you should connect Bluetooth dongles if there is no Bluetooth support. And Bluetooth driver should be pre-install. Then , you must follow up below steps on you rPC 1. Power on HT580L and then Run Bluetooth manager from PC 2. Click New Connection buttom 3. Select proper mode Express Mode or Customer Mode. User can specify COM port number if select customer mode. Unitech Part Number: 400412 13 4. Then it will search all of Bluetooth device within BT converge area and then list them down on the screen. You can find all of HT580Ls will be displayed as UNITECH. Then you can click Next button 5. Then it will prompt user to enter PIN code, HT580Ls default PIN (Pass key) is 0580, then you can find this HT580L is already on your Bluetooth list. Then click right mouse button to connect it. 6. You can also check the correct PORT number from Detail PS. HT580Ls BT Device name is fixed on UNITECH, so you will see a lots of UNITECH on Bluetooth Manager if you want to connect several HT580Ls to single PC. And user can not identify which one is correct HT580L to map to list. So, it is suggested to power on one HT580L at a time when make connection and please note its MAC address from DETAIL. Unitech Part Number: 400412 14 2.3. Communication program In Easy Job, it also bundle one communication program named MultiEj. You can directly run it from
HT580L EasyJob
Or it from HT580L Easy Job and then then select Tool Communication as below diagram
Then it will launch MultiEj program as below screen, You can directly 1. drag and drop files from PC folder to HT580L directory to execute download function 2. drag and drop files from HT580L directory to PC folder to execute upload function 3. directly select files on HT580L directory area and delete. Unitech Part Number: 400412 15
Before using MultiEj to do communication, you should setup correct port number and communication parameter by chick Options icon on menu bar.
Then click NEW button to select a new COM port, then configure its proper communication parameter and click OK button to finish setting. Then you can select proper port from Connection List Box
After select proper COM port, you will find icons of Date/Time , WarmStart and ColdStart changed from grey to color icon.
Download / Upload / Delete / Execute will also become color if you select click files on local file area or remote files area Unitech Part Number: 400412 16 2.4. Modem communication For HT580L, Unitech provide modem cradle to enable modem communication function between PC and HT580L. So, user must connect phone line to cradle and HT580L still connect to cradle with RS232 interface. There are 2 ways to do connection. 1. Calling from PC 2. Calling from Terminal
Call from PC To call modem from PC, HT580Ls modem cradle should be set to automatically pick up external call. So, you should put HT580L into cradle (cradle should be connect to power) and execute Setting Modem and then select AUTO ANSWER to let HT580L send ATS0=1 to modem board (inside cradle). Then, cradle can automatically pick up external calling after one ring tone. (After execute AUTO ANSWER, it is not suggested to power off cradle, or Auto Answer function will be disappeared) In PC, you can use MultiEj to do modem communication with HT580L, you can setup modem function from Options by check Modem check Then setup to correct Initial command, dial number, and wait time.
Call from HT580L Current, HT580L can support modem dial from F/W. We will provide modem function from EasyJob in the future. In PC side, you can use Hyperterminal to setup modem Auto Answer. And please put HT580L into cradle and phone line should be connected to cradle. Then follow up below step 4. Execute Setting Modem Phone to input correct phone number 5. Then execute Setting Modem Dial out to connect to remote After end of communication, execute Setting Modem Hang to hang up phone. Unitech Part Number: 400412 17 Unitech Part Number: 400412 18 3. Technical Specification Model HT580L Dimensions Weight 123mm x 55mm x 25mm 150g Drop Specification 1.2M free drop to concrete floor Display Battery Environmental Sealing Operation Temperature Storage Temperature 128 x 64 pixel; 16x8 characters or 12x4 characters One 3.7V 730mAH Li-ion battery IP42 0C~50C
-20C ~70C Humidity 5% to 95% RH, ; not condensed Electrostatic Discharge
(ESD) Back-Lit Display 4 KV contact discharge 8 KV air discharge Yes Keypads CPU Operating System 18 alphanumeric keys including one scan trigger ST UPSD3354DV Proprietary ( C Language) Memory 1 MB for main program & data storage Application Development Communication EZ Job RS232/USB1.1/ Bluetooth/Modem Battery Life Symbologies Buzzer One LED Up to 8 hours UPC/EAN, Code 39, Interleave 2 of 5, CODABAR, MSI, Code 128, Code 93, Code 32,China Postal Code Yes, over 75 dB Reading green color Unitech Part Number: 400412 19 3.1. Pin Assignment The HT580L communicate via the RS232 communication port located on the bottom of the unit. You can connect the unit via the communication cable to PC RS232 jack for data transfer or connect through cradle for communication. Pin 1 2 3 4 5 6 7 8 9 10 11 12 Name US-POWER GND DC-IN USB DP CTS RTS DSR GND DTR TXD RXD USB DP Unitech Part Number: 400412 20 Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. Unitech Part Number: 400412 21