all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
Users Manual | Users Manual | 2.19 MiB | October 07 2015 | |||
1 | Cover Letter(s) | October 07 2015 | ||||||
1 | Cover Letter(s) | October 07 2015 | ||||||
1 | External Photos | October 07 2015 | ||||||
1 | Cover Letter(s) | October 07 2015 | ||||||
1 | ID Label/Location Info | October 07 2015 | ||||||
1 | Internal Photos | October 07 2015 | ||||||
1 | RF Exposure Info | October 07 2015 | ||||||
1 | Test Report | October 07 2015 | ||||||
1 | Test Setup Photos | October 07 2015 |
1 | Users Manual | Users Manual | 2.19 MiB | October 07 2015 |
Wireless(BT) Pocket Laser Scanner
- MS916 -
User's Manual Version 1.0 2015 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co., Ltd. Table of Contents Chapter 1 Overview..........................................................................................................1 Package Contents ........................................................................................1 Scanner Detail..............................................................................................3 Getting Started .............................................................................................4 BATTERY CHARGING.................................................................................4 Pairing With PC/Notebook For The First Time..............................................5 Specifications ...............................................................................................6 Chapter 2 MS916 Setting Code........................................................................................9 Chapter 3 Setting Up MS916..........................................................................................15 MS916 Menu Tree......................................................................................14 General Setting ..........................................................................................16 Data & Memory ..........................................................................................19 BT Configuring ...........................................................................................20 Barcode setting ..........................................................................................22 Disable All Code .........................................................................................22 Chapter 4 Parameter Menus ..........................................................................................24 Introduction ................................................................................................23 Operational Parameters .............................................................................23 Set Default Parameter................................................................................28 Beeper Volume...........................................................................................29 Beeper Tone ...............................................................................................29 Laser On Time............................................................................................30 Aim Duration...............................................................................................31 Triggering Modes........................................................................................31 Time-out Between Same Symbol ...............................................................33 Beep After Good Decode............................................................................33 Parameter Scanning...................................................................................34 i Parameter Pass Through ...........................................................................34 Disable All Symbologies .............................................................................35 Linear Code Type Security Level................................................................36 Bi-directional Redundancy .........................................................................37 UPC/EAN ...................................................................................................38 Code 128....................................................................................................46 Code 39......................................................................................................47 Code 93......................................................................................................52 Code 11 ......................................................................................................54 Interleaved 2 of 5........................................................................................57 Discrete 2 of 5 ............................................................................................61 Chinese 2 of 5 ............................................................................................63 Codabar .....................................................................................................63 MSI.............................................................................................................66 GS1 DataBar ..............................................................................................70 Transmit Code ID Character.......................................................................72 Prefix/Suffix Values.....................................................................................73 Scan Data Transmission Format ................................................................74 Numeric Bar Codes ....................................................................................76 ii Overview Package Contents Please make sure the following contents are in the MS916 gift box. If something is missing or damaged, please contact your Unitech representative. The standard package contents MS916 Scanner Resource CD Quick Reference Guide Micro USB to USB Cable Whist Strap
- 1 -
Optional accessories 1-Slot Charging cradle 5-Slot Charging cradle USB Adapter NOTE: 1. The scanners default power off time is 5 minutes. 2. Please charge scanner for at least 2 hours prior to initial use.
- 2 -
Scanner Detail Page up / Page down keys Move up / down through list of menu items Scan Window Scan LED (Green LED) It will light up while the barcode is successfully scanned Laser Warning Label Micro USB Connector For scanner charging and data transmission
- 3 -
Scan & Power Button Power On/Off & Scan barcode Charging Status LED (Red LED) It will light up while the scanner is charging Product Label Getting Started To scan a barcode, make sure the aiming beam crosses every bar and space of the barcode. BATTERY CHARGING Insert the mini USB connector into the port on the scanner and the standard mini USB connector of the USB cable into a USB port on the host PC.
- 4 -
Pairing With PC/Notebook For The First Time PC (HID mode) Following steps are based on Microsoft Windows 7. 1. Turn on MS916 and then press the Page Down button to enter BT Pairing mode. 2. Open Devices and Printers by clicking the Start button
, and then, on the Start menu, clicking Devices and Printers. 3. Click Add a device, and then follow the instructions. 4. Click the Bluetooth enabled device (MS916-[XXXXXX]) you want to add to your computer, and then click Next. If you don't see the device you want to add, make sure the device is turned on and discoverable. If you just turned on the device, it may take Windows several seconds to detect it.
- 5 -
Specifications System Display OS Memory Key 1" OLED, 128 x 64 Proprietary, Connect to host with Windows, Android and iOS 64 Kbytes SRAM / 16MB Flash ROM 3 Keys: Page up, Page down, Scan with power on/off feature Optical & Performance Receiving Device Laser Engine Light Source 650 nm visible laser diode Max. Resolution 4mil Scan Rate 104 scans/second Skew Angle 473 degrees Pitch Angle 353 degrees Printing Contrast Scale Depth of Field
(DOF PCS=80%) minimum 25%
Symbology | Density | Near | Far Code 39, 4 mils | 2.5 cm | 13.97 cm Code 39, 5 mils | 3.18 cm | 20.32 cm Code 39, 7.5 mils | 3.81 cm | 33.02 cm Code 39, 10 mils | 3.81 cm | 45.72 cm Code 39, 15 mils | 3.81 cm | 71.72 cm Code 39, 20 mils | 4.45 cm | 83.82 cm Code 39, 40 mils | x | 91.44 cm Code 39, 55 mils | x | 114.3 cm UPC, 13 mils | 3.81 cm | 60.96 cm
- 6 -
Functionality Symbologies 1D Code 39, Full ASCII Code 39, Interleave 2 of 5, UPC A/E/E1, MSI, Codabar, Code 11, EAN8/13, Code 93, Code 128, EAN 128, Code32, GS1 databar Code, Bookland EAN, Discreate 2 of 5, Chinese 2 of 5, ISBT 128, UCC Coupon Extended Code, Bookland 128 Postal Australian Post, BPO, Canada Post, Dutch Post, Japan Post, PostNet, Sweden Post Operation Mode Trigger mode, Pulse mode, Flash mode, Continuous Mode, Buffer mode Data Formatting Prefix, Suffix, Code ID, Reformatting Date Environmental ESD Protection Functional after 8K Contact and 12K Air Mechanical Shock 1.5m onto concrete (scanner only) IP Rate IP42 Operating Temperature Storage Temperature 0C to 50C
-30C to 70C Relative Humidity 95% non-condensing Electrical Operation Voltage DC 3V to 5V Current Consumption Battery Type Operation mode: TBD, Standby mode: TBD Rechargeable Li-ion battery battery Battery Capacity 770 mAh Battery Charging time Operating Time Fully charged in about 3 hours 10 hours at condition of 1 scan/5 sec
- 7 -
Communication Radio Frequency Bluetooth V2.1+EDR. Class 2 Protocol Range Wireless SPP & HID profiles Up to 30 Feet (Open space) Host Interface supported USB Mechanical Scanner Dimension H21.1*W36.9*L95.9mm Scanner Weight 63g Switch life 10 million times Regulation Approvals CE, FCC, BSMI, VCCI
- 8 -
Chapter 2 MS916 Setting Code
*for FW v0.35 or later Scanner Type BT HID *
BT SPP USB SPP BT SPP (Slave) Operation Mode Wedge Batch Auto *
BT Pairing Bluetooth Config Paired Device Remove Pair System Restore & Info Factory Default Send Info
- 9 -
Data & Memory Send Batch Erase Last Memory Entry Free Memory Space Erase Memory Beeper & Vibrator Control High Volume Medium Volume *
Low Volume Mute & Vibrate Mute Beep / Vibrate Enabled for Good Read *
Disabled for Good Read Enabled for Connection *
Disabled for Connection 5 Seconds 20 Seconds Power Saving 10 Seconds 15 Seconds Disable 30 Seconds
- 10 -
Auto Power Off 1 Minute 3 Minutes 5 Minutes *
10 Minutes 30 Minutes 15 Minutes 20 Minutes Disable
- 11 -
HID Keyboard Character Delay 1 ms *
5 ms 10 ms 20 ms 10 ms *
500 ms Auto Trace *
100 ms 50 ms HID Keyboard Block Delay 50 ms 100 ms 1 Sec. 3 Sec. HID Keyboard Case To Lower To Upper
- 12 -
HID Keyboard Language US English *
UK English Swiss Swedish German Partial ALT ALT Mode Norwegian French Japanese (OADG109) Italian Danish Spanish
- 13 -
Chapter 3 Default Setting BT HID Setting Up MS916 MS916 Menu Tree Top Menu Sub Menu Level 1 Sub Menu Level 2 Options/Result 1. Scanner Type 2. Operation Mode BT HID/USB SPP/
BT SPP (Master)/BT SPP (Slave) Auto Mode/Wedge Mode/Batch Mode Auto Mode 3.1 View Date/Time Show date and time N/A 3. Date/Time 3.2 Set Date/Time SET DATE/SET TIME General Setting 3.3 Time Display Auto/Always 3.4 Exit Return to the previous menu 4.1 Power Saving Disable/30/20/15/10/5 Sec. 4. Power Manager 4.2 Auto Power Off Disable/30/20/15/10/5/3/1 Min. 4.3 Exit Return to the previous menu 5. FAC Default 6.1 Restore to FAC Default?
Yes/No 6. FW Version 7. Exit Show Firmware Version Return to the previous menu 1. Buffer Data 1.1. Erase Previous Buffer Entry?
Yes/No 2. Batch Data 2.1. Erase Previous Batch Entry?
Yes/No 2015-01-01 08:00:00 Auto N/A 15 Sec. 5 Min. N/A No V0.32 N/A No No Data &
3. Free Mem Space Show Free Buffer and Batch Memory Space N/A Memory 4. Erase Memory 4.1. Erase Buffer 4.2. Erase Batch Yes/No Yes/No 5. Exit Return to the previous menu No No N/A
- 14 -
1. BT Pairing 2. BT MAC Addr 3. BT Paired Dev BT Configuring 4. Remove Pairing 5. BT FW Version 6. Exit Beep &
Vibrate 1. Disable All Code 2. UPC-A 3. UPC-E 4. EAN-8 5. EAN-13 6. Code 39 7. Code 128 8. EAN 128 Barcode 9. I 2 of 5 setting 10. Code 93 11. Codabar 12. Code 11 13. MSI 14. UPC-E1 15. Bookland EAN 16. Discreate 2 of 5 17. Chinese 2 of 5 18. GS1-14 Enter BT pairing Show BT MAC Address N/A N/A Show BT paired Name and MAC Address N/A Yes/No (If a BT device has been paired with MS916) Show BT Firmware Version Return to the previous menu High Volume/Medium Volume/
Low Volume/Mute&Vibrate/Mute ON/OFF Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable Enable/Disable No N/A N/A Medium Volume OFF Enable Enable Enable Enable Enable Enable Enable Enable Disable Disable Disable Disable Disable Disable Disable Disable Disable
- 15 -
To enter main menu of MS916, press Page Up and Page Down button simultaneously. You will see the following screen on the MS916 display. Now you can use Page Up/Down button to scroll through the menu and use Scan button to make your selection. The following sections will introduce each function in the menu. General Setting Scanner Type
- MS916 can be set to five types: BT HID/USB SPP/BT SPP (Master)/BT SPP (Slave). The default scanner type is BT HID. Operation Mode
- MS916 can be operated under three modes: Auto Mode/Wedge Mode/Batch Mode. The default operation mode is Auto Mode.
- 16 -
Date/Time
- There are 4 functions under Date/Time menu. The View Date/Time function can show date/time which has been set in MS916 on the scanner display.
- You can use Set Date/Time function to set current date/time. First enter current date (yyyy-mm-dd) and then current time (hh:mm:ss).
- You can use Time Display function to set time to be either Always or Auto displayed. The default value is Auto.
- The final function Exit can guide you to return to previous menu level. Power Manager
- The first function under Power Manager menu is Power Saving. You can use this function to choose the time duration for the scanner coming into idle mode after no command received. The default value is 15 seconds.
- You can use Auto Power Off to choose the time duration for the scanner turning off automatically after no command received. The default value is 5 minutes.
- The final function Exit can guide you to return to previous menu level.
- 17 -
Beep & Vibrate
- You can use Beep & Vibrate function to set scanners beep volume and turn on/off scanner vibration. The options are: High Volume/Medium Volume/Low Volume/Mute&Vibrate/Mute. The default option is Medium Volume. FAC Default
- Use this function to restore MS916 to factory default. FW Version
- Use this function to show the current FW version of MS916.
- 18 -
Data & Memory Buffer Data
- You can use Buffer Data function to erase previous buffer entry. Batch Data
- You can use Batch Data function to erase previous batch entry. Free Mem Space
- You can use Free Mem Space function to see how much free buffer and batch memory left.
- 19 -
Erase Memory
- Under ERASE MEMORY menu, you can select Erase Buffer and Erase Batch function.
- You can use Erase Buffer function to empty buffer memory.
- You can use Erase Batch function to empty batch memory. BT Configuring BT Pairing
- You can use BT Pairing function to pair MS916 with your host device.
(PC/Notebook/Smartphone/etc.) After select this function, MS916 will be discoverable and ready to connect with your host device.
- 20 -
BT MAC Address
- You can use BT MAC ADDR function to show the BT MAC address of MS916. BT Paired Device
- You can use BT PAIRED DEV function to show the name and MAC address of the paired Bluetooth device. Remove Pairing
-
If a BT device has been paired with MS916, you can use this function to remove the connection.
- 21 -
BT FW Version
- You can use BT FW Version to show the Bluetooth firmware version of MS916. Barcode setting Disable All Code
- You can use Disable All Code function to turn on/off all barcodes scanning availability. UPC-A / UPC-E / EAN-8 / EAN-13 / Code 39 / Code 128 / EAN 128 / I 2 of 5 / Code 93 / Codabar /
Code 11 / MSI / UPC-E1 / Bookland EAN /
Discreate 2 of 5 / Chinese 2 of 5 / GS1-14
- You can Enable or Disable these supported barcodes scanning availability.
- 22 -
Chapter 4 Parameter Menus Introduction This chapter describes the programmable parameters, provides bar codes for programming, and hexadecimal equivalents for host parameter programming through SSI. Operational Parameters The MS916 is shipped with the factory default settings shown in Table 3-1 on page 26. These factory default values are stored in non-volatile memory and are preserved even when the scan engine is powered down. Changes to the factory default values can be stored as custom defaults. These values are also stored in non-volatile memory and are preserved even when the scan engine is powered down. To change the parameter values:
Scan the appropriate bar codes included in this chapter. The new values replace the existing memory values. To set the new values as custom defaults, scan the Write to Custom Defaults bar code. The factory default or custom default parameter values can be recalled by scanning the Set Factory Defaults bar code or the Restore Defaults bar code on page 29. or Send the parameter through the scan engines serial port using the SSI command PARAM_SEND. Hexadecimal parameter numbers are shown in this chapter below the parameter title, and options appear in parenthesis beneath the accompanying bar codes. Instructions for changing parameters using this method are found in Chapter 10, Simple Serial Interface.
- 23 -
Parameter Programming Recommendations When setting parameters via bar code or via SSI with the permanent flag set, the following conditions must be met:
The system must have stable power applied to the scanner. The engine and host must be operating and communicating with no interference. Power must be maintained for at least two seconds after sending the command or scanning the parameter bar code. If sending parameters upon every power up, ensure they are temporary. Motorola does not recommend sending permanent parameters or Set Defaults upon every power up. Motorola also recommends not using a hard power switch on the power supply. Failure to meet these conditions can corrupt the scan engine's memory.
- 24 -
Parameter Defaults Table 3-1 lists the factory defaults for all parameters. To change any option, scan the appropriate bar code(s). Table 3-1 Factory Default Table Parameter Parameter Number
(Hex) Factory Default Page Number Set Factory Default Beeper Volume Beeper Tone Laser On Time Aim Duration Trigger Mode Time-out Between Same Symbol Beep After Good Decode Parameter Scanning 0x8C 0x91 0x88 0xED 0x8A 0x89 0x38 0xEC Parameter Pass Through F1h 71h Disable All Symbologies Linear Code Type Security Levels Bi-directional Redundancy UPC/EAN UPC-A UPC-E UPC-E1 EAN-8 EAN-13 Bookland EAN UPC-A Preamble UPC-E Preamble UPC-E1 Preamble Convert UPC-E to A Convert UPC-E1 to A EAN-8 Zero Extend N/A 0x4E 0x43 0x01 0x02 0x0C 0x04 0x03 0x53 0x22 0x23 0x24 0x25 0x26 0x27 Bookland ISBN Format F1h 40h Code 128 Code 128 Code 39 Code 39 Trioptic Code 39 0x08 0x00 0x0D
- 25 -
All Defaults Medium Medium Frequency 3.0 sec 0.0 sec Level 1.0 sec Enable Enable Disable N/A 1 Disable Enable Enable Disable Enable Enable Disable System Character System Character System Character Disable Disable Disable ISBN-10 Enable Enable Disable 29 30 30 31 32 32 34 34 35 35 36 37 38 39 40 40 41 41 42 42 43 44 45 45 46 46 47 48 48 Convert Code 39 to Code 32 Code 32 Prefix Set Length(s) for Code 39 Code 39 Check Digit Verification Transmit Code 39 Check Digit Code 39 Full ASCII Conversion Code 93 Code 93 Set Length(s) for Code 93 Code 11 Code 11 Set Lengths for Code 11 Code 11 Check Digit Verification Transmit Code 11 Check Digit(s) Interleaved 2 of 5 Interleaved 2 of 5 Set Length(s) for I 2 of 5 I 2 of 5 Check Digit Verification Transmit I 2 of 5 Check Digit Convert I 2 of 5 to EAN 13 Discrete 2 of 5 Discrete 2 of 5 Set Length(s) for D 2 of 5 Chinese 2 of 5 Chinese 2 of 5 Codabar Codabar Set Lengths for Codabar CLSI Editing NOTIS Editing MSI MSI Set Length(s) for MSI 0x56 0xE7 0x12 0x13 0x30 0x2B 0x09 0x1A 0x1B 0x0A 0x1C 0x1D 0x34 0x2F 0x06 0x16 0x17 0x31 0x2C 0x52 0x05 0x14 0x15 0xF0 0x98 0x07 0x18 0x19 0x36 0x37 0x0B 0x1E 0x1F
- 26 -
Disable Disable 2-55 Disable Disable Disable Disable 4-55 Disable 4 to 55 Disable Disable Enable 14 Disable Disable Disable Disable 12 Disable Disable 5-55 Disable Disable Disable 6-55 49 49 50 51 52 52 53 54 55 56 57 58 58 59 60 61 61 62 62 64 64 65 66 67 67 68 MSI Check Digits Transmit MSI Check Digit MSI Check Digit Algorithm GS1 DataBar GS1 DataBar-14 GS1 DataBar Limited GS1 DataBar Expanded Convert GS1 DataBar to UPC/EAN Data Options Transmit Code ID Character Prefix/Suffix Values Prefix Suffix 1 Suffix 2 Scan Data Transmission Format 0x32 0x2E 0x33 0xF0 0x52 0xF0 0x53 0xF0 0x54 0xF0 0x8D 0x2D 0x69 0x68 0x6A 0xEB One Disable Mod 10/Mod 10 Disable Disable Disable Disable None NULL LF CR Data as is 69 70 70 71 71 72 72 73 74 75
- 27 -
Set Default Parameter The MS916 can be reset to two types of defaults: factory defaults or custom defaults. Scan the appropriate bar code below to reset the MS916 to its default settings and/or set the scan engines current settings as the custom default. Restore Defaults - Scan this bar code to reset all default parameters as follows. If custom defaults were set by scanning Write to Custom Defaults, scan Restore Defaults to retrieve and restore the scan engines custom default settings. If no custom defaults were set, scan Restore Defaults to restore the factory default values listed in Table 3-1 on page 26. Set Factory Defaults - Scan this bar code to restore the factory default values listed in Table 3-1 on page 26. If custom defaults were set, they are eliminated. Write to Custom Defaults - Scan this bar code to store the current scan engine settings as custom defaults. Once custom default settings are stored, they can be recovered at any time by scanning Restore Defaults.
- 28 -
Beeper Volume Parameter # 0x8C To select a decode beep volume, scan the appropriate bar code. Beeper Tone Parameter # 0x91 To select a decode beep frequency (tone), scan the appropriate bar code.
- 29 -
Laser On Time Parameter # 0x88 This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1 second increments from 0.50 to 25.5 seconds. To set a Laser On Time, scan the bar code below. Next scan two numeric bar codes beginning on page 77 that correspond to the desired on time. Single digit numbers must have a leading zero. For example, to set an on time of 0.5 seconds, scan the bar code below, then scan the "0", "5" and "0" bar codes; to set an on time of 10.5 seconds, scan the bar code below, then scan the "1", "0"
and "5" bar codes. To change the selection or cancel an incorrect entry, scan Cancel on page 78.
- 30 -
Aim Duration Parameter # 0xED When a scan engine with an aim mode is triggered either by a trigger pull, or a START_DECODE command, this parameter sets the duration the aiming pattern is seen before a a scan attempt begins. It does not apply to the aim signal or the AIM_ON command. It is programmable in 0.1 second increments from 0.0 to 9.9 seconds. No aim pattern is visible when the value is 0.0. To set an aim duration, scan the bar code below. Next scan two numeric bar codes beginning on page 77 that correspond to the desired aim duration. Single digit numbers must have a leading zero. For example, to set an aim duration of 0.5 seconds, scan the bar code below, then scan the 0 and 5 bar codes. To change the selection or cancel an incorrect entry, scan Cancel on page 78. Triggering Modes Parameter # 0x8A Choose one of the options below to trigger the scan engine. Bar codes and option numbers are on the following page. Scan (Level) - A trigger pull activates the laser and decode processing. The laser remains on and decode processing continues until a trigger release, a valid decode, or the Laser On Time-out is reached. Scan (Pulse) - A trigger pull activates the laser and decode processing. The laser remains on and decode processing continues until a valid decode or the Laser On Time-out is reached.
- 31 -
Continuous - The laser is always on and decoding. Blink - This trigger mode is used for trigger less operation. Scanning range is reduced in this mode. This mode cannot be used with engines that support an aim mode. Host - A host command issues the triggering signal. The scan engine interprets an actual trigger pull as a Level triggering option.
- 32 -
Time-out Between Same Symbol Parameter # 0x89 When in Continuous triggering mode, this parameter sets the minimum time that must elapse before the scan engine decodes a second bar code identical to one just decoded. This reduces the risk of accidently scanning the same symbol twice. It is programmable in 0.1 second increments from 0.0 to 9.9 seconds. To set a time-out between same symbol, scan the bar code below. Next scan two numeric bar codes beginning on page 77 that correspond to the desired time-out. Single digit values must have a leading zero. For example, to set a time-out of 0.5 seconds, scan the bar code below, then scan the 0 and 5 bar codes. To change the selection or cancel an incorrect entry, scan Cancel on page 78. Beep After Good Decode Parameter # 0x38 Scan this symbol to set the scan engine to beep after a good decode.
- 33 -
Scan this symbol to set the scan engine not to beep after a good decode. The beeper still operates during parameter menu scanning and indicates error conditions. Parameter Scanning Parameter # 0xEC To disable decoding of parameter bar codes, scan the bar code below. The Set Defaults parameter bar code can still be decoded. To enable decoding of parameter bar codes, either scan Enable Parameter Scanning below, Set Factory Defaults on page 29 or set this parameter to 0x01 via a serial command. Parameter Pass Through Parameter # 0xF1 0x71 Enable Parameter Pass Through to transmit bar codes in the following format, in Code 128, to the host:
- 34 -
<FNC3>L<any length data>
<FNC3>B<12 characters of data>
Note that the special Code 128 character <FNC3> must appear at the beginning of this data. However, if the appropriate data does not follow this as shown above, it does not transmit to the host device. Disable All Symbologies Scan the bar code below to disable the decoding of all symbologies. Use this to simplify selecting a single symbology to decode by scanning this, then scanning the desired enable code type bar code. Note that the decoder can still decode parameter bar codes.
- 35 -
Linear Code Type Security Level Parameter # 0x4E The MS916 offers four levels of decode security for linear code types (e.g. Code 39, Interleaved 2 of 5). Select higher security levels for decreasing levels of bar code quality. As security levels increase, the scan engines aggressiveness decreases. Select the security level appropriate for your bar code quality. Linear Security Level 1 The following code types must be successfully read twice before being decoded:
Code Type Length Codabar All MSI D 2 of 5 I 2 of 5 4 or less 8 or less 8 or less Linear Security Level 2 All code types must be successfully read twice before being decoded.
- 36 -
Linear Security Level 3 Code types other than the following must be successfully read twice before being decoded. The following codes must be read three times:
Code Type Length MSI D 2 of 5 I 2 of 5 4 or less 8 or less 8 or less Linear Security Level 4 All code types must be successfully read three times before being decoded. Bi-directional Redundancy Parameter # 0x43 This parameter is only valid when a Linear Code Type Security Level is enabled (see page 37). When this parameter is enabled, a bar code must be successfully scanned in both directions (forward and reverse) before being decoded.
- 37 -
UPC/EAN Enable/Disable UPC-A Parameter # 0x01 To enable or disable UPC-A, scan the appropriate bar code below.
- 38 -
Enable/Disable UPC-E Parameter # 0x02 To enable or disable UPC-E, scan the appropriate bar code below. Enable/Disable UPC-E1 Parameter # 0x0C To enable or disable UPC-E1, scan the appropriate bar code below. NOTE UPC-E1 is not a UCC (Uniform Code Council) approved symbology.
- 39 -
Enable/Disable EAN-8 Parameter # 0x04 To enable or disable EAN-8, scan the appropriate bar code below. Enable/Disable EAN-13 Parameter # 0x03 To enable or disable EAN-13, scan the appropriate bar code below.
- 40 -
Enable/Disable Bookland EAN Parameter # 0x53 To enable or disable EAN Bookland, scan the appropriate bar code below. NOTE If you enable Bookland EAN, select a Bookland ISBN Format on page 46. UPC-A Preamble Parameter # 0x22 Preamble characters (Country Code and System Character) can be transmitted as part of a UPC-A symbol. Select one of the following options for transmitting UPC-A preamble to the host device: transmit system character only, transmit system character and country code (0 for USA), or transmit no preamble.
- 41 -
UPC-E Preamble Parameter # 0x23 Preamble characters (Country Code and System Character) can be transmitted as part of a UPC-E symbol. Select one of the following options for transmitting UPC-E preamble to the host device: transmit system character only, transmit system character and country code (0 for USA), or transmit no preamble.
- 42 -
UPC-E1 Preamble Parameter # 0x24 Preamble characters (Country Code and System Character) can be transmitted as part of a UPC-E1 symbol. Select one of the following options for transmitting UPC-E1 preamble to the host device: transmit system character only, transmit system character and country code (0 for USA), or transmit no preamble.
- 43 -
Convert UPC-E to UPC-A Parameter # 0x25 Enable this parameter to convert UPC-E (zero suppressed) decoded data to UPC-A format before transmission. After conversion, data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit). Scan DO NOT CONVERT UPC-E TO UPC-A to transmit UPC-E (zero suppressed) decoded data. Convert UPC-E1 to UPC-A Parameter # 0x26 Enable this parameter to convert UPC-E1 (zero suppressed) decoded data to UPC-A format before transmission. After conversion, data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit). Scan DO NOT CONVERT UPC-E TO UPC-A to transmit UPC-E1 (zero suppressed) decoded data.
- 44 -
EAN Zero Extend Parameter # 0x27 When enabled, this parameter adds five leading zeros to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols. Disable this parameter to transmit EAN-8 symbols as is. Bookland ISBN Format Parameter # 0xF1 0x40 If you enabled Bookland EAN using Enable/Disable Bookland EAN on page 42, select one of the following formats for Bookland data:
- 45 -
Bookland ISBN-10 - The scanner reports Bookland data starting with 978 in traditional 10-digit format with the special Bookland check digit for backward-compatibility. Data starting with 979 is not considered Bookland in this mode. Bookland ISBN-13 - The scanner reports Bookland data (starting with either 978 or 979) as EAN-13 in 13-digit format to meet the 2007 ISBN-13 protocol. NOTE For Bookland EAN to function properly, first enable Bookland EAN using Enable/Disable Bookland EAN on page 42. Code 128 Enable/Disable Code 128 Parameter # 0x08 To enable or disable Code 128, scan the appropriate bar code below.
- 46 -
Code 39 Enable/Disable Code 39 Parameter # 0x00 To enable or disable Code 39, scan the appropriate bar code below. Enable/Disable Trioptic Code 39 Parameter # 0x0D Trioptic Code 39 is a variant of Code 39 used in marking computer tape cartridges. Trioptic Code 39 symbols always contain six characters. To enable or disable Trioptic Code 39, scan the appropriate bar code below.
- 47 -
NOTE Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously. If an error beep sounds when enabling Trioptic Code 39, disable Code 39 Full ASCII and try again. Convert Code 39 to Code 32 (Italian Pharma Code) Parameter # 0x56 Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry. Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32. NOTE Code 39 must be enabled in order for this parameter to function. Code 32 Prefix Parameter # 0xE7 Enable this parameter to add the prefix character A to all Code 32 bar codes. Convert Code 39 to Code 32 (Italian Pharma Code) must be enabled for this parameter to function.
- 48 -
Set Lengths for Code 39 Parameter # L1 = 0x12, L2 = 0x13 The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Lengths for Code 39 may be set for any length, one or two discrete lengths, or lengths within a specific range. If Code 39 Full ASCII is enabled, Length Within a Range or Any Length are the preferred options. To set lengths via serial commands, see Setting Code Lengths Via Serial Commands on page B-6. NOTE When setting lengths, single digit numbers must always be preceded by a leading zero. One Discrete Length - This option limits decodes to only those Code 39 symbols containing a selected length. Lengths are selected from the numeric bar codes beginning on page 77. For example, to decode only Code 39 symbols with 14 characters, scan Code 39 - One Discrete Length, then scan 1 followed by 4. To change the selection or cancel an incorrect entry, scan Cancel on page 78. Two Discrete Lengths - This option limits decodes to only those Code 39 symbols containing either of two selected lengths. Lengths are selected from
- 49 -
the numeric bar codes beginning on page 77. For example, to decode only those Code 39 symbols containing either 2 or 14 characters, select Code 39 -
Two Discrete Lengths, then scan 0, 2, 1, and then 4. To change the selection or cancel an incorrect entry, scan Cancel on page 78. Length Within Range - This option limits decodes to only those Code 39 symbols within a specified range. For example, to decode Code 39 symbols containing between 4 and 12 characters, first scan Code 39 - Length Within Range. Then scan 0, 4, 1, and 2. Numeric bar codes begin on page 77. To change the selection or cancel an incorrect entry, scan Cancel on page 78. Any Length - Scan this option to decode Code 39 symbols containing any number of characters. Code 39 Check Digit Verification Parameter # 0x30 When this feature is enabled, the scan engine checks the integrity of all Code 39 symbols to verify that the data complies with specified check digit algorithm. Only those Code 39 symbols which include a modulo 43 check digit are decoded. Only enable this feature if your Code 39 symbols contain a module 43 check digit.
- 50 -
Transmit Code 39 Check Digit Parameter # 0x2B Scan this symbol to transmit the check digit with the data. Scan this symbol to transmit data without the check digit. Enable/Disable Code 39 Full ASCII Parameter # 0x11 Code 39 Full ASCII is a variant of Code 39 which pairs characters to encode the full ASCII character set. To enable or disable Code 39 Full ASCII, scan the appropriate bar code below. See Table B-5 on page B-7 for the mapping of Code 39 characters to ASCII values.
- 51 -
NOTE Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously. If you get an error beep when enabling Code 39 Full ASCII, disable Trioptic Code 39 and try again. Code 93 Enable/Disable Code 93 Parameter # 0x09 To enable or disable Code 93, scan the appropriate bar code below.
- 52 -
Set Lengths for Code 93 Parameter # L1 = 0x1A, L2 = 0x1B The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Lengths for Code 93 may be set for any length, one or two discrete lengths, or lengths within a specific range. To set lengths via serial commands, see Setting Code Lengths Via Serial Commands on page B-6. One Discrete Length - Select this option to decode only those codes containing a selected length. For example, select Code 93 One Discrete Length, then scan 1, 4, to limit the decoding to only Code 93 symbols containing 14 characters. Numeric bar codes begin on page 77. To change the selection or cancel an incorrect entry, scan Cancel on page 78. Two Discrete Lengths - Select this option to decode only those codes containing two selected lengths. For example, select Code 93 Two Discrete Lengths, then scan 0, 2, 1, 4, to limit the decoding to only Code 93 symbols containing 2 or 14 characters. Numeric bar codes begin on page 77. To change the selection or cancel an incorrect entry, scan Cancel on page 78. Length Within Range - This option sets the unit to decode a code type within a specified range. For example, to decode Code 93 symbols containing between 4 and 12 characters, first scan Code 93 Length Within Range, then scan 0, 4, 1 and 2 (single digit numbers must always be preceded by a leading zero).
- 53 -
Numeric bar codes begin on page 77. To change the selection or cancel an incorrect entry, scan Cancel on page 78. Any Length - Scan this option to decode Code 93 symbols containing any number of characters. Code 11 Enable/Disable Code 11 Parameter # 0x0A To enable or disable Code 11, scan the appropriate bar code below.
- 54 -
Set Lengths for Code 11 Parameter # L1 = 0x1C, L2 = 0x1D The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 11 to any length, one or two discrete lengths, or lengths within a specific range. One Discrete Length - Select this option to decode only Code 11 symbols containing a selected length. Select the length using the numeric bar codes beginning on page 77. For example, to decode only Code 11 symbols with 14 characters, scan Code 11 - One Discrete Length, then scan 1 followed by 4. To correct an error or to change the selection, scan Cancel on page 78. Two Discrete Lengths - Select this option to decode only Code 11 symbols containing either of two selected lengths. Select lengths using the numeric bar codes beginning on page 77. For example, to decode only those Code 11 symbols containing either 2 or 14 characters, select Code 11 - Two Discrete Lengths, then scan 0, 2, 1, and then 4. To correct an error or to change the selection, scan Cancel on page 78. Length Within Range - Select this option to decode a Code 11 symbol with a specific length range. Select lengths using numeric bar codes beginning on page 77. For example, to decode Code 11 symbols containing between 4 and 12 characters, first scan Code 11
- Length Within Range. Then scan 0, 4, 1, and 2 (single digit numbers must always be preceded by a leading zero). To correct an error or change the selection, scan Cancel on page 78. Any Length - Scan this option to decode Code 11 symbols containing any number of characters within the scan engine capability.
- 55 -
Code 11 Check Digit Verification Parameter # 0x34 This feature allows the scan engine to check the integrity of all Code 11 symbols to verify that the data complies with the specified check digit algorithm. This selects the check digit mechanism for the decoded Code 11 bar code. The options are to check for one check digit, check for two check digits, or disable the feature. To enable this feature, scan the bar code below corresponding to the number of check digits encoded in your Code 11 symbols.
- 56 -
Transmit Code 11 Check Digits Parameter # 0x2F This feature selects whether or not to transmit the Code 11 check digit(s). NOTE Code 11 Check Digit Verification must be enabled for this parameter to function. Interleaved 2 of 5 Enable/Disable Interleaved 2 of 5 Parameter # 0x06 To enable or disable Interleaved 2 of 5, scan the appropriate bar code below.
- 57 -
Set Lengths for Interleaved 2 of 5 Parameter # L1 = 0x16, L2 = 0x17 The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Lengths for I 2 of 5 may be set for any length, one or two discrete lengths, or lengths within a specific range. To set lengths via serial commands, see Setting Code Lengths Via Serial Commands on page B-8. NOTE When setting lengths, single digit numbers must always be preceded by a leading zero. One Discrete Length - Select this option to decode only those codes containing a selected length. For example, select I 2 of 5 One Discrete Length, then scan 1, 4, to decode only I 2 of 5 symbols containing 14 characters. Numeric bar codes begin on page 77. To change the selection or cancel an incorrect entry, scan Cancel on page 78. Two Discrete Lengths - Select this option to decode only those codes containing two selected lengths. For example, select I 2 of 5 Two Discrete Lengths, then scan 0, 6, 1, 4, to decode only I 2 of 5 symbols containing 6 or 14 characters. Numeric bar codes begin on page 77. To change the selection or cancel an incorrect entry, scan Cancel on page 78.
- 58 -
Length Within Range - Select this option to decode only codes within a specified range. For example, to decode I 2 of 5 symbols containing between 4 and 12 characters, first scan I 2 of 5 Length Within Range, then scan 0, 4, 1 and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 77. To change the selection or cancel an incorrect entry, scan Cancel on page 78. Any Length - Scan this option to decode I 2 of 5 symbols containing any number of characters. NOTE Selecting this option may lead to misdecodes for I 2 of 5 codes. I 2 of 5 Check Digit Verification Parameter # 0x31 When enabled, this parameter checks the integrity of an I 2 of 5 symbol to ensure it complies with a specified algorithm, either USS (Uniform Symbology Specification), or OPCC (Optical Product Code Council).
- 59 -
Transmit I 2 of 5 Check Digit Parameter # 0x2C Scan this symbol to transmit the check digit with the data. Scan this symbol to transmit data without the check digit. Convert I 2 of 5 to EAN-13 Parameter # 0x52 This parameter converts a 14 character I 2 of 5 code into EAN-13, and transmits to the host as EAN-13. To accomplish this, I 2 of 5 must be enabled, one length must be set to 14, and the code must have a leading zero and a valid EAN-13 check digit.
- 60 -
Discrete 2 of 5 Enable/Disable Discrete 2 of 5 Parameter # 0x05 To enable or disable Discrete 2 of 5, scan the appropriate bar code below. Set Lengths for Discrete 2 of 5 Parameter # L1 = 0x14, L2 = 0x15 The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Lengths for D 2 of 5 may be set for any length, one or two discrete lengths, or lengths within a
- 61 -
specific range. To set lengths via serial commands, see Setting Code Lengths Via Serial Commands on page B-6. One Discrete Length - Select this option to decode only those codes containing a selected length. For example, select D 2 of 5 One Discrete Length, then scan 1, 4, to decode only D 2 of 5 symbols containing 14 characters. Numeric bar codes begin on page 77. To change the selection or cancel an incorrect entry, scan Cancel on page 78. Two Discrete Lengths - Select this option to decode only those codes containing two selected lengths. For example, select D 2 of 5 Two Discrete Lengths, then scan 0, 2, 1, 4, to decode only D 2 of 5 symbols containing 2 or 14 characters. Numeric bar codes begin on page 77. To change the selection or cancel an incorrect entry, scan Cancel on page 78. Length Within Range - Select this option to decode codes within a specified range. For example, to decode D 2 of 5 symbols containing between 4 and 12 characters, first scan D 2 of 5 Length Within Range, then scan 0, 4, 1 and 2
(single digit numbers must be preceded by a leading zero). Numeric bar codes begin on page 77. To change the selection or cancel an incorrect entry, scan Cancel on page 78. Any Length - Scan this option to decode D 2 of 5 symbols containing any number of characters. NOTE Selecting this option may lead to misdecodes for D 2 of 5 codes.
- 62 -
Chinese 2 of 5 Enable/Disable Chinese 2 of 5 Parameter # 0xF0 0x98 To enable or disable Chinese 2 of 5, scan the appropriate bar code below. Codabar Enable/Disable Codabar Parameter # 0x07 To enable or disable Codabar, scan the appropriate bar code below.
- 63 -
Set Lengths for Codabar Parameter # L1 = 0x18, L2 = 0x19 The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Lengths for Codabar may be set for any length, one or two discrete lengths, or lengths within a specific range. To set lengths via serial commands, see Setting Code Lengths Via Serial Commands on page B-6. One Discrete Length - Select this option to decode only those codes containing a selected length. For example, select Codabar One Discrete Length, then scan 1, 4, to decode only Codabar symbols containing 14 characters. Numeric bar codes begin on page 77. To change the selection or cancel an incorrect entry, scan Cancel on page 78. Two Discrete Lengths - This option sets the unit to decode only those codes containing two selected lengths. For example, select Codabar Two Discrete Lengths, then scan 0, 2, 1, 4, to decode only Codabar symbols containing 6 or 14 characters. Numeric bar codes begin on page 77. To change the selection or cancel an incorrect entry, scan Cancel on page 78.
- 64 -
Length Within Range - Select this option to decode a code within a specified range. For example, to decode Codabar symbols containing between 4 and 12 characters, first scan Codabar Length Within Range, then scan 0, 4, 1 and 2
(single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 77. To change the selection or cancel an incorrect entry, scan Cancel on page 78. Any Length - Scan this option to decode Codabar symbols containing any number of characters. CLSI Editing Parameter # 0x36 When enabled, this parameter strips the start and stop characters and inserts a space after the first, fifth, and tenth characters of a 14-character Codabar symbol. NOTE Symbol length does not include start and stop characters.
- 65 -
NOTIS Editing Parameter # 0x37 When enabled, this parameter strips the start and stop characters from decoded Codabar symbol. MSI Enable/Disable MSI Parameter # 0x0B To enable or disable MSI, scan the appropriate bar code below.
- 66 -
Set Lengths for MSI Parameter # L1 = 0x1E, L2 = 0x1FT The length of a code refers to the number of characters (i.e., human readable characters) the code contains, and includes check digits. Lengths for MSI can be set for any length, one or two discrete lengths, or lengths within a specific range. See Table B-5 on page B-9 for ASCII equivalents. To set lengths via serial commands, see Setting Code Lengths Via Serial Commands on page B-6. One Discrete Length - Select this option to decode only those codes containing a selected length. For example, select MSI Plessey One Discrete Length, then scan 1, 4, to decode only MSI Plessey symbols containing 14 characters. Numeric bar codes begin on page 77. To change the selection or cancel an incorrect entry, scan Cancel on page 78. Two Discrete Lengths - Select this option to decode only those codes containing two selected lengths. For example, select MSI Plessey Two Discrete Lengths, then scan 0, 6, 1, 4, to decode only MSI Plessey symbols containing 6 or 14 characters. Numeric bar codes begin on page 77. To change the selection or cancel an incorrect entry, scan Cancel on page 78.
- 67 -
Length Within Range - Select this option to decode codes within a specified range. For example, to decode MSI symbols containing between 4 and 12 characters, first scan MSI Length Within Range, then scan 0, 4, 1 and 2
(single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 77. To change the selection or cancel an incorrect entry, scan Cancel on page 78. Any Length - Scan this option to decode MSI Plessey symbols containing any number of characters. NOTE Selecting this option may lead to misdecodes for MSI codes. MSI Check Digits Parameter # 0x32 These check digits at the end of the bar code verify the integrity of the data. At least one check digit is always required. Check digits are not automatically transmitted with the data.
- 68 -
If two check digits are selected, also select an MSI Check Digit Algorithm on page 70. Transmit MSI Check Digit Parameter # 0x2E Scan this symbol to transmit the check digit with the data. Scan this symbol to transmit data without the check digit. MSI Check Digit Algorithm Parameter # 0x33 When the Two MSI check digits option is selected, an additional verification is required to ensure integrity. Select one of the following algorithms.
- 69 -
GS1 DataBar Enable/Disable GS1 DataBar-14 Parameter # 0xF0 0x52 To enable or disable GS1 DataBar-14, scan the appropriate bar code below. Enable/Disable GS1 DataBar Limited Parameter # 0xF0 0x53 To enable or disable GS1 DataBar Limited, scan the appropriate bar code below.
- 70 -
Enable/Disable GS1 DataBar Expanded Parameter # 0xF0 0x54 To enable or disable GS1 DataBar Expanded, scan the appropriate bar code below. Convert GS1 DataBar to UPC/EAN Parameter # 0xF0 0x8D This parameter only applies to GS1 DataBar-14 and GS1 DataBar Limited symbols. When this conversion is enabled, GS1 DataBar-14 and GS1 DataBar Limited symbols encoding a single zero as the first digit have the leading '010'
stripped and the bar code reported as EAN-13.
- 71 -
Bar codes beginning with two or more zeros but not six zeros have the leading
'0100' stripped and the bar code reported as UPC-A. The UPC-A Preamble parameter to transmit the system character and country code applies to converted bar codes. Note that neither the system character nor the check digit can be stripped. Transmit Code ID Character Parameter # 0x2D A code ID character identifies the code type of a scanned bar code. This can be useful when decoding more than one code type. The code ID character is inserted between the prefix character (if selected) and the decoded symbol. Select no code ID character, a Symbol Code ID character, or an AIM Code ID character. The Symbol Code ID characters are listed below; see Appendix B, Miscellaneous Code Information for AIM Code Identifiers. A = UPC-A, UPC-E, UPC-E1, EAN-8, EAN-13 B = Code 39, Code 32 C = Codabar D = Code 128, ISBT 128 E = Code 93 F = Interleaved 2 of 5 G = Discrete 2 of 5 J = MSI
- 72 -
K = GS1-DataBar L = Bookland EAN M = Trioptic Code 39 N = Coupon Code R = GS1 DataBar-14, GS1 DataBar Limited, GS1 DataBar Expanded. Prefix/Suffix Values Parameter # P = 0x69, S1 = 0x68, S2 = 0x6A A prefix and/or one or two suffixes can be appended to scan data for use in data editing. To set these values, scan a four-digit number (i.e. four bar codes) that corresponds to ASCII values. See the Table B-5 on page B-7 and Numeric Bar Codes on page 77. To change the selection or cancel an incorrect entry, scan Cancel on page 78. To set the Prefix/Suffix values via serial commands, see Setting Prefixes and Suffixes Via Serial Commands on page B-7.
- 73 -
NOTE In order to use Prefix/Suffix values, the Scan Data Transmission Format on page 75 must be set. See page 75. Scan Data Transmission Format Parameter # 0xEB To change the Scan Data Transmission Format, scan one of the eight bar codes corresponding to the desired format.
- 74 -
- 75 -
Numeric Bar Codes For parameters requiring specific numeric values, scan the appropriately numbered bar code(s).
- 76 -
Cancel To change the selection or cancel an incorrect entry, scan the bar code below.
- 77 -
Regulatory Compliance Statements FCC Warning Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference with radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference with radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. 1. This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 2. This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. To maintain compliance with FCC RF exposure requirements, avoid direct contact to the transmitting antenna during transmitting. 3. Any changes or modifications (including the antennas) made to this device that are not expressly approved by the manufacturer may void the users authority to operate the equipment.
- 78 -
FCC Label Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Canadian Compliance Statement This Class B Digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numerique de la classe B respecte les exigences du Reglement sur le material broilleur du Canada. European Conformity Statement This device complies with the R&TTE Directive (1999/5/EC) issued by the Commission of the European Community. RoHS Statement This device conforms to RoHS (Reduction Of Hazardous Substances) European Union regulations that set maximum concentration limits on hazardous materials used in electrical and electronic equipment. TaiwanNCC Warning Statement
- 79 -
Laser Information The Unitech MS916 series is certified in the U.S. to conform to the requirements of DHHS/CDRH 21CFR Subchapter J and to the requirements of IEC 825-1. Class II and Class 2 products are not considered to be hazardous. The MS916 series contains internally a Visible Laser Diode (VLD) whose emissions do not exceed the maximum limits as set forth in the above regulations. The scanner is designed so that there is no human access to harmful laser light during normal operation, user maintenance or prescribed service operations. The laser safety warning label required by the DHHS/IEC for the MS916 series' optional laser scanner module is located on the memory compartment cover, on the back of the unit. CAUTION! Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light. Use of optical instruments with the scanner, including binoculars, microscopes, and magnifying glasses, with will increase eye damage. This does not include eyeglasses worn by the user.
- 80 -
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2015-07-10 | 2402 ~ 2480 | DSS - Part 15 Spread Spectrum Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2015-07-10
|
||||
1 | Applicant's complete, legal business name |
Unitech Electronics Co., Ltd.
|
||||
1 | FCC Registration Number (FRN) |
0023101058
|
||||
1 | Physical Address |
5F, No. 136, Lane 235, Pao-Chiao Rd.
|
||||
1 |
Hsin-Tien Dist., New Taipei City,, N/A
|
|||||
1 |
Taiwan
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
c******@telefication.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
HLE
|
||||
1 | Equipment Product Code |
MS916BT
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
B******** C****
|
||||
1 | Telephone Number |
886-2********
|
||||
1 | Fax Number |
886-2********
|
||||
1 |
B******@tw.ute.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
BTL Inc.
|
||||
1 | Name |
S****** L****
|
||||
1 | Physical Address |
B1, No. 37, Lane 365, YangGuang St.
|
||||
1 |
Taiwan
|
|||||
1 | Telephone Number |
86-76******** Extension:
|
||||
1 | Fax Number |
86-76********
|
||||
1 |
c******@newbtl.com
|
|||||
app s | Non Technical Contact | |||||
1 | Firm Name |
BTL Inc.
|
||||
1 | Name |
C******** W****
|
||||
1 | Physical Address |
B1, No. 37, Lane 365, YangGuang St.
|
||||
1 |
Taiwan
|
|||||
1 | Telephone Number |
86-76******** Extension:
|
||||
1 | Fax Number |
86-76********
|
||||
1 |
c******@newbtl.com
|
|||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DSS - Part 15 Spread Spectrum Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Wireless Pocket Laser Scanner | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power output listed is conducted. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
BTL Inc.
|
||||
1 | Name |
A******** C******
|
||||
1 | Telephone Number |
886-2******** Extension:
|
||||
1 | Fax Number |
886-2********
|
||||
1 |
A******@newbtl.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2402.00000000 | 2480.00000000 | 0.0030000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC