Wireless Contact Sensor User's Manual Product Name: Wireless Contact Sensor Model No: WCS-110 Input Power: 3V DC Features Description:
1. Wireless transmission to the reed switch (opens / closes) the signal to the repeater, we can see that the doors and windows open and close the current state, to prevent thieves invasive. 2. Use CR2032 type Li-ion batteries, battery power is insufficient to inform the host will automatically operate a very low power; the battery can be used for more than two years. 3. Easy link, when install at the first time to press the set button on the side of product binding with repeater. Outline Dimensions:
Feature Locator:
Installation Hints:
1. Foundation stop plate 2. State of LED window 3. reed switch location 4. battery holder 5. (SET) Setting button 1. Need to WCS-110 (Wireless Contact Sensor) Foundation stop plate and the magnet block to be installed on the doors or windows to detect in order to start using. 2. WCS-110 (Wireless Contact Sensor) Battery installation instructions are as follows maps, Add spin to open the battery holder, and then can be closed.
(Attention: CR2032 Battery Positive side up) 3. WCS-110 (Wireless Contact Sensor) mounted to the Foundation stop plate described below map, linked to the drop of a good position to. 4. WCS-110 (Wireless Contact Sensor) by pressing the SET button at the bottom, and then press the WR-110 (wireless repeater) at the bottom of the SET button, Wait for 30 seconds to 1 minute. If LED indicator light flash three times that means linking success. If LED indicator light flash two times that means fail. 5. Join to link with Gateway, please reference user manual of WCC-110 (Wireless console controller). 6. WCS-110 (Wireless Contact Sensor) Ontology positive signs at the top right of the arrow, there is a need to align with the magnet above the center line, when the interval between the two for less than 10mm away from the normal state, if the interval between the two left more than 20mm Police will send radio. 7. WCS-110 (Wireless Contact Sensor) Foundation stop plate can as shown below, doors or window frames placed in a static position, the magnet body in the door or window frame fixed movable parts. 8. Under the Foundation stop plate can map the location of locking screw holes in order to pay Gum adhesive or screw fixed way, Easy DIY installation of WCS-110(Wireless Contact Sensor) Ontology and Ontology magnet fixed on the door or window frame. Troubleshooting:
1. Problem : When link with WR-110 (Wireless repeater), there is no display of LED indicator light for WCS-110 (Wireless Contact Sensor) to flash two or three times. Solution : a. Need to make sure the battery is good there is electricity, the installation of the battery positive and negative direction is correct. b. May be not press set button, need to link with repeater again. c. If the above handles are invalid, please contact with agency. 2. Problem : Unable to link with WR-110 (wireless repeater). Solution : a. It needs to confirm the distance between WCS-110 (Wireless Contact Sensor) and WR-110 (Wireless repeater). Wireless connects in non-camouflage straight line effective range 10 meters. May pull closer between booth's distance tests to have a look first, whether to have the improvement segment condition Specification:
Model No. Electrical Specification Transmit Frequency Modulation Transmit Power Channel spacing Channel NO. Range of operation Operating voltage Current (typical) Battery Type Battery Quantity (PCS) Sensor Type Display Type Wireless Contact Sensor WCS-110 2.4GHz GFSK 0 dBm 1 MHz 81 Channel(2401~2481Mhz) 10 meters 3.0V DC Working: 14mA Peak Standby: 1 uA Max CR2032 1 Reed Switch Red LED indicator Operation Interface Push button switch for setting Environmental Requirement Operating temperature Storage temperature Humidity Mechanical Specification
-20C to 60C
-20C to 70C 90% RH Max. Non-Condensing Dimension (WxHxD, mm) 34x66x15 Weight (No Battery) Weight (Include Battery) 22 g 25 g FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Connect the equipment into an outlet on a circuit different from that to which the Increase the separation between the equipment and receiver. receiver is connected. Consult the dealer or an experienced radio/TV technician for help. CAUTION:
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference and
(2) This device must accept any interference received, including interference that may cause undesired operation. Canada Warning
"Industry Canada regulatory information Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.""The user is cautioned that this device should be used only as specified within this manual to meet RF exposure requirements. Use of this device in a manner inconsistent with this manual could lead to excessive RF exposure conditions."