all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 2 |
|
User Manual | Users Manual | 1.65 MiB | ||||
1 2 | Cover Letter(s) | |||||||
1 2 | Cover Letter(s) | |||||||
1 2 | External Photos | |||||||
1 2 | Internal Photos | |||||||
1 2 | ID Label/Location Info | |||||||
1 2 | ID Label/Location Info | |||||||
1 2 | Cover Letter(s) | |||||||
1 2 | RF Exposure Info | |||||||
1 2 |
|
Test Report | Test Report | 4.50 MiB | ||||
1 2 | Test Setup Photos | |||||||
1 2 | Cover Letter(s) |
1 2 | User Manual | Users Manual | 1.65 MiB |
User Manual Features Control Panel Watertight Cap Tie-down Feature 6x9 Speaker Slip-proof Feet 1 Tweeter loud.outdoor.audio 1 www.turtleboxaudio.com Product Overview 1. Power On/Off and Play/Pause Button 2. Bluetooth Source Pairing Button (1BT) 3. Turtlebox Stereo Pairing Button (2BT) 4. Previous Track Button 5. Next Track Button 6. Down Volume Button 7. Up Volume Button 8. 3.5mm Port 9. MiniUSB Charging Port 2 4 6 1 7 2 8 3 5 9 2 www.turtleboxaudio.com Simple Operation Power Up:
Power Down:
Source Pair:
Stereo Pair:
Break Source:
Break Stereo Pair:
3.5mm Source:
Play/Pause:
Previous/Next Tracking:
Volume Down/Up:
Depress Power Button 2 seconds Depress Power Button 2 seconds Every Turtlebox powers up ready to source pair. Find Turtlebox on the list of Bluetooth devices and select it to pair Every Turtlebox powers up ready to stereo pair. Press 2BT on any box and it will stereo pair with the nearest box Press 1BT. Press again to reestablish Press 2BT on either box Plug in 3.5mm cord. This will override any Bluetooth source.
(The boxes cannot be paired while sourced through 3.5mm) Quickly press Power Button Press Left/Right track buttons Press Left/Right volume buttons Note for volume: Volume is not tethered. The source regulates its own volume. The box regulates its own volume. Note for stereo pairing: The boxes play a true left/right channel stereo sound. One box will be the left channel master and the other will be the right channel slave. The box with both 1BT and 2BT indicators solid blue is the master box. The slave will be 1BT dark, and 2BT solid blue. Keep the source nearer to the master Turtlebox. 2 Charging the Turtlebox Please fully charge your speaker before use. The battery indicator (Power button light) will be red whilst charging. Turtlebox is fully charged when the indicator light is green. 1. Plug in wall charger 2. Unscrew watertight cap 3. Connect MiniUSB charging port to the included wall charger 3 www.turtleboxaudio.com Warning!!
Your Turtlebox speaker has an IP67 rating, as it is waterproof, sandproof, and dustproof. Nonetheless, special precautions must be heeded when using your speaker. 1. The waterproof screw-cap on the top of your speaker must be securely closed when using your speaker in conditions where water or moisture are present. Failure to do so can cause damage to your speaker. Always keep the cap closed around water. 2. Do not use your speaker in standing water, floating in water, or in extreme weather situations such as thunder and lightning storms. 3. Do NOT allow your speaker to be exposed to any water or moisture while it is being charged or while it is plugged into a power outlet. Doing so can raise the risk of electric shock and also cause damage to your speaker. 4. Make sure your speaker is completely dry before charging or plugging it into a power outlet. Similarly, any phones or other devices paired with your speaker should be kept dry during use unless otherwise noted by the devices manufacturer. Care and Maintenance Before using your speaker, inspect the ports and jacks to make sure that they are clear of dust and debris before charging or inserting an AUX Cable. Do not drop, disassemble, deform, modify or insert any objects into this product as operating damage will result. Use a soft cloth to clean your speaker. Never use any harsh chemicals, detergents, alcohol, ammonia-based cleaners, or abrasive cleaners. Ensure your speaker is dry beforecharging. When your speaker is not in use, it should be stored in a cool, dry place. Never tug or yank on the charging cables or AUX Cable while they are connected to your speaker. Connect and disconnect these cables as carefully as possible. If your speaker is exposed to salt water, wash it off with fresh water and then dry thoroughly before using. Do not bring your product in contact with any sharp objects as this may cause scratches and operating damage. Please recycle of dispose of your speaker properly based on the laws and rules of your municipality. Do not dispose of the battery with regular household waste. Important Safety Precautions &
Battery Information 1. Do not allow children or the infirm to play with your speaker without adult supervision. 2. Do not place this product on its side, slanted surfaces as well as the edge of high surfaces, like shelves, during music play to prevent accidental falls. 3. Do not operate in enclosed areas, or covered with anything. Let the product operate with good ventilation to prevent overheating. 4. Do not expose your speaker to excessive heat, flames or fire. 5. Always press all buttons carefully. Do not manhandle your speaker. 6. Do not use in extremely dry environments, as this can lead to static discharge during use. 7. Do not expose your speaker to temperatures above 36 degrees Celsius. Keep out of direct sunlight for long periods of time, especially in the summer and in high heat. 8. Do not listen to your speaker at high volumes for extended periods of time. 9. Observe all signs and displays that require an electrical device or RF radio product to be switched off in designated areas. 10. Turn off your product prior to boarding an aircraft. Do not use the product inside an aircraft unless directed by the airline. 11. Do not attempt to repair this product yourself. Contact a qualified service center if your speaker is in need of service. 12. Do not drop, puncture or expose your speaker to excessive trauma. 13. Your speaker is not intended for commercial use. 14. Do not place speaker near objects that generate a strong magnetic field. 15. Unplug this device when not in use for long periods of time or during lightning storms. 16. The device is equipped with an integrated lithium ion battery. The battery cannot be replaced. Do not attempt to remove the battery from the device. 17. The battery used in this device may present a risk of fire or chemical burn if mistreated. 18. Do not ever attempt to open box, this will void your warranty. 19. Observe all signs and displays that require an electrical device or RF radio product to be switch off in designated areas. 20. Dispose of the product and the products battery in accordance with local laws and regulations. Do not dispose of the battery with regular household waste. 4 www.turtleboxaudio.com To reduce the risk of fire or electric shock, do not expose the TURTLEBOX to water or moisture while charging. As with any electronic products, use care not to spill liquids into any part of the product. Liquids can cause a failure and/or a fire hazard. The power supply must be used indoors only. Make no modifications to the product or accessories. Unauthorized alterations may compromise safety, regulatory compliance, and system performance, and will void the warranty. Do not place any flame sources, such as lighted candles, on or near the TURTLEBOX. The TURTLEBOX contains small parts that may be a choking hazard and is not suitable for children under age 3. Do not continue charging the battery if it does not reach full charge within the specified charging time. Overcharging may cause the battery to become hot, rupture, or ignite. If you see any heat deformation or leakage, properly dispose of the battery. Do not attempt to charge the battery in temperatures outside the range of 32-104F (0-40C). If the battery begins to leak, do not allow the liquid to come in contact with your skin or eyes. If contact has been made, wash the affected area with plenty of water and seek medical attention immediately. Do not expose the product or battery to excessive heat, including direct sunlight or fire and storage or use inside cars in hot weather, where it can be exposed to temperatures in excess of 115F (60C). Doing so may cause the battery and power supply to generate heat, rupture, or ignite. Using the product in this manner also may result in a loss of performance and a shortened life expectancy. Extended exposure to direct sunlight may damage the external appearance and material qualities. Do not step on, throw, or drop batteries or the power supply or device, or expose them to a strong shock. Do not pierce, crush, dent, or deform the batteries or power supply in any way. If either becomes deformed, properly dispose of it. Do not short-circuit batteries. Do not attempt to service the TURTLEBOX yourself. Opening or removing covers may expose you to dangerous voltages or other hazards and will void the manufacturers warranty. To prevent risk of fire or electric shock, avoid overloading wall outlets, extension cords, or integral convenience receptacles. Certifications This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates use and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or experienced radio / TV technician for help. FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate this equipment. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. Industry Canada (IC) Compliance Notice This device complies with the Industry Canada license-exempt RSS standard(s). Operation is subject to the following 2 conditions: 1) this device may not cause interference, and 2) this device must accept any interference, including interference that may cause undesired operation of the device. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and it gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. We hope you enjoy your product as much as we enjoy it. We have built this product to last and handle just about any environment you find yourself in. If however you have any problems with the product dont hesitate to reach out to our Technical support staff:
Technical Support For technical support issues please visit our website at www.turtleboxaudio.com. You can find manuals, software and FAQs at the website. Thank you for purchasing a turtlebox, our mission is to make the loudest outdoor portable product on the market. We hope you enjoy it as much as we do. 5 www.turtleboxaudio.com- French:"
Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes :
(1) l'appareil nedoit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement."
1 2 | Test Report | Test Report | 4.50 MiB |
Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page1 of 52 Report No.: SZAWW180614005-02 FCC TEST REPORT For UNITEIC COMPANY LIMITED TURTLE BOX Model No.: TURTLE BOX Prepared For Address
: UNITEIC COMPANY LIMITED
: Gaolong Industrial, Huanzhuli Village,Changping Town Dongguan Guangdong, China. Prepared By Address
: Shenzhen Anbotek Compliance Laboratory Limited
: 1/F, Building D, Sogood Science and Technology Park, Sanwei community, Hangcheng Street, Bao'an District, Shenzhen, Guangdong, China.518102 Tel: (86) 755-26066440 Fax: (86) 755-26014772 Report Number Date of Test Date of Report
: SZAWW180614005-02
:
:
Jun. 14~29, 2018 Jun. 29, 2018 Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page2 of 52 Report No.: SZAWW180614005-02 Contents 1. General Information..................................................................................................................................................5 1.1. Client Information......................................................................................................................................... 5 1.2. Description of Device (EUT)........................................................................................................................ 5 1.3. Auxiliary Equipment Used During Test........................................................................................................ 5 1.4. Description of Test Modes.............................................................................................................................6 1.5. List of channels..............................................................................................................................................7 1.6. Description Of Test Setup..............................................................................................................................8 1.7. Test Equipment List....................................................................................................................................... 9 1.8. Measurement Uncertainty............................................................................................................................10 1.9. Description of Test Facility......................................................................................................................... 10 2. Summary of Test Results........................................................................................................................................ 11 3. Conducted Emission Test........................................................................................................................................12 3.1. Test Standard and Limit...............................................................................................................................12 3.2. Test Setup.....................................................................................................................................................12 3.3. Test Procedure..............................................................................................................................................12 3.4. Test Data...................................................................................................................................................... 12 4. Radiation Spurious Emission and Band Edge........................................................................................................17 4.1. Test Standard and Limit...............................................................................................................................17 4.2. Test Setup.....................................................................................................................................................17 4.3. Test Procedure..............................................................................................................................................18 4.4. Test Data...................................................................................................................................................... 19 5. Maximum Peak Output Power Test........................................................................................................................26 5.1. Test Standard and Limit...............................................................................................................................26 5.2. Test Setup.....................................................................................................................................................26 5.3. Test Procedure..............................................................................................................................................26 5.4. Test Data...................................................................................................................................................... 26 6. 6DB Occupy Bandwidth Test................................................................................................................................. 29 6.1. Test Standard and Limit...............................................................................................................................29 6.2. Test Setup.....................................................................................................................................................29 6.3. Test Procedure..............................................................................................................................................29 6.4. Test Data...................................................................................................................................................... 29 7. Power Spectral Density Test...................................................................................................................................32 7.1. Test Standard and Limit...............................................................................................................................32 7.2. Test Setup.....................................................................................................................................................32 7.3. Test Procedure..............................................................................................................................................32 7.4. Test Data...................................................................................................................................................... 32 8. 100kHz Bandwidth of Frequency Band Edge Requirement.................................................................................. 35 8.1. Test Standard and Limit...............................................................................................................................35 8.2. Test Setup.....................................................................................................................................................35 8.3. Test Procedure..............................................................................................................................................35 8.4. Test Data...................................................................................................................................................... 35 9. Antenna Requirement............................................................................................................................................. 39 Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page3 of 52 Report No.: SZAWW180614005-02 9.1. Test Standard and Requirement...................................................................................................................39 9.2. Antenna Connected Construction................................................................................................................39 APPENDIX I -- TEST SETUP PHOTOGRAPH.......................................................................................................40 APPENDIX II -- EXTERNAL PHOTOGRAPH....................................................................................................... 42 APPENDIX III -- INTERNAL PHOTOGRAPH.......................................................................................................47 Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page4 of 52 Report No.: SZAWW180614005-02 TEST REPORT Applicant
: UNITEIC COMPANY LIMITED Manufacturer
: UNITEIC COMPANY LIMITED Product Name
: TURTLE BOX Model No. Trade Mark Rating(s)
: TURTLE BOX
: N.A.
:
Input: DC 14.4V, 2A (Via adapter Input: AC 110V~240V, Max: 0.8A; with DC 11.1V, 5200 mAh Battery inside) Test Standard(s) Test Method(s)
: FCC Part15 Subpart C 2017, Section 15.247
: ANSI C63.10: 2013, KDB558074 D01 DTS Meas Guidance v04 The device described above is tested by Shenzhen Anbotek Compliance Laboratory Limited to determine the maximum emission levels emanating from the device and the severe levels of the device can endure and its performance criterion. The measurement results are contained in this test report and Shenzhen Anbotek Compliance Laboratory Limited is assumed full of responsibility for the accuracy and completeness of these measurements. Also, this report shows that the EUT (Equipment Under Test) is technically compliant with the FCC Part 15 Subpart C requirements. This report applies to above tested sample only and shall not be reproduced in part without written approval of Shenzhen Anbotek Compliance Laboratory Limited. Date of Test Prepared by Reviewer Approved & Authorized Signer Jun. 14~29, 2018
(Engineer / Oliay Yang)
(Supervisor / Calvin Liu)
(Manager / Tom Chen) Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page5 of 52 Report No.: SZAWW180614005-02 1. General Information 1.1. Client Information Applicant Address
: UNITEIC COMPANY LIMITED
: Gaolong Industrial, Huanzhuli Village,Changping Town Dongguan Guangdong, China. Manufacturer Address
: UNITEIC COMPANY LIMITED
: Gaolong Industrial, Huanzhuli Village,Changping Town Dongguan Guangdong, China. 1.2. Description of Device (EUT) Product Name Model No. Trade Mark Test Power Supply
: TURTLE BOX
: TURTLE BOX
: N.A.
: AC 240V, 60Hz for adapter/ AC 120V, 60Hz for adapter/DC 11.1V Battery inside Product Description
:
Operation Frequency:
Transfer Rate:
Number of Channel:
Modulation Type:
Antenna Type:
Antenna Gain(Peak):
2402MHz-2480MHz 1 Mbits/s 40 Channel GFSK PCB Antenna 0 dBi Remark: 1)For a more detailed features description, please refer to the manufacturers specifications or the Users Manual. 2)This report is for BLE. 1.3. Auxiliary Equipment Used During Test Adapter
: M/N: CP1420 Input: 100V-240V~ 50/60Hz, 0.8A Output: DC 14.4V, 2A Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page6 of 52 Report No.: SZAWW180614005-02 1.4. Description of Test Modes To investigate the maximum EMI emission characteristics generates from EUT, the test system was pre-scanning tested base on the consideration of following EUT operation mode or test configuration mode which possible have effect on EMI emission level. Each of these EUT operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively. Pretest Mode Mode 1 Mode 2 Mode 3 Mode 4 Final Test Mode Mode 4 Final Test Mode Mode 1 Mode 2 Mode 3 Mode 4 Description CH00 CH19 CH39 Keeping TX+Charging mode For Conducted Emission Description Keeping TX+Charging mode For Radiated Emission Description CH00 CH19 CH39 Keeping TX+Charging mode Note:
(1) The measurements are performed at the highest, middle, lowest available channels.
(2)The data rate was set in 1Mbps for radiated emission due to the highest RF output power. Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page7 of 52 Report No.: SZAWW180614005-02 1.5. List of channels Channel 00 01 02 03 04 05 06 07 08 Freq.
(MHz) 2402 2404 2406 2408 2410 2412 2414 2416 2418 Channel 09 10 11 12 13 14 15 16 17 Freq.
(MHz) 2420 2422 2424 2426 2428 2430 2432 2434 2436 Channel 18 19 20 21 22 23 24 25 26 Freq.
(MHz) 2438 2440 2442 2444 2446 2448 2450 2452 2454 Channel 27 28 29 30 31 32 33 34 35 Freq.
(MHz) 2456 2458 2460 2462 2464 2466 2468 2470 2472 Channel 36 37 38 39 Freq.
(MHz) 2474 2476 2478 2480 Note:
1. The engineering test program was provided and the EUT was programmed to be in continuously transmitting mode. 2. EUT built-in battery-powered, fully-charged battery use of the test battery. Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page8 of 52 Report No.: SZAWW180614005-02 1.6. Description Of Test Setup USB E-1 EUT E-2 Adapter AC Line LISN CE 0.8m RE 0.8m Table Table 1.5m E-1 EUT 1.5m Table Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page9 of 52 Report No.: SZAWW180614005-02 1.7. Test Equipment List Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval L.I.S.N. Artificial Mains Rohde & Schwarz ENV216 100055 Nov. 17, 2017 1 Year Network EMI Test Receiver Rohde & Schwarz ESCI 100627 Nov. 17, 2017 1 Year RF Switching Unit Spectrum Analysis Spectrum Analysis Preamplifier EMI Test Receiver Double Ridged Horn Antenna Bilog Broadband Antenna Loop Antenna Horn Antenna Pre-amplifier EMI Test Software EZ-EMC RF Test Control System Power Sensor Power Sensor MXA Spectrum Analysis MXG RF Vector Signal Generator Signal Generator DC Power Supply Constant Temperature Humidity Chamber Compliance Direction Agilent Agilent RSU-M2 E4407B N9038A SKET Electronic BK1G18G30D Rohde & Schwarz ESCI KD17503 100627 38303 Nov. 17, 2017 1 Year US39390582 MY53227295 Nov. 17, 2017 Nov. 17, 2017 Nov. 17, 2017 Nov. 17, 2017 1 Year 1 Year 1 Year 1 Year Instruments corporation GTH-0118 351600 Nov. 20, 2017 1 Year Schwarzbeck VULB9163 VULB 9163-289 Nov. 20, 2017 1 Year Schwarzbeck Schewarzbeck SONOMA SHURPLE HFH2-Z2 BBHA9170 310N N/A 100047 9170-375 186860 Nov. 17, 2017 Nov. 17, 2017 Nov. 17, 2017 N/A N/A 1 Year 1 Year 1 Year N/A YIHENG YH3000 2017430 Nov. 18, 2017 1 Year DAER DAER Agilent Agilent Agilent LW Sertep RPR3006W 15I00041SN045 Nov. 17, 2017 RPR3006W 15I00041SN046 Nov. 17, 2017 1 Year 1 Year N9020A MY51170037 Nov. 18, 2017 1 Year N5182A MY48180656 Nov. 18, 2017 1 Year E4421B MY41000743 TPR-6410D 349315 Nov. 18, 2017 Nov. 01, 2017 1 Year 1 Year ZJ-HWHS80B ZJ-17042804 Nov. 01, 2017 1 Year Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page10 of 52 Report No.: SZAWW180614005-02 1.8. Measurement Uncertainty Radiation Uncertainty
: Ur = 3.9 dB (Horizontal) Ur = 3.8 dB (Vertical) Conduction Uncertainty
: Uc = 3.4 dB 1.9. Description of Test Facility The test facility is recognized, certified, or accredited by the following organizations:
FCC-Registration No.: 184111 Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registed and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. Registration No. 184111, July 31, 2017. ISED-Registration No.: 8058A-1 Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registered and fully described in a report filed with the (ISED) Innovation, Science and Economic Development Canada. The acceptance letter from the ISED is maintained in our files. Registration 8058A-1, June 13, 2016. Test Location All Emissions tests were performed at Shenzhen Anbotek Compliance Laboratory Limited. at 1/F, Building D, Sogood Science and Technology Park, Sanwei community, Hangcheng Street, Bao'an District, Shenzhen, Guangdong, China.518102 Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page11 of 52 Report No.: SZAWW180614005-02 2. Summary of Test Results Standard Section 15.203/15.247(c) 15.207 15.205/15.209 15.247(b)(3) 15.247(a)(2) 15.247(e) 15.247(d) Test Item Antenna Requirement Conducted Emission Spurious Emission Conducted Peak Output Power 6dB Occupied Bandwidth Power Spectral Density Band Edge Remark: N/A is an abbreviation for Not Applicable. Result PASS PASS PASS PASS PASS PASS PASS Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page12 of 52 Report No.: SZAWW180614005-02 3. Conducted Emission Test 3.1. Test Standard and Limit Test Standard FCC Part15 Section 15.207 Test Limit Frequency 150kHz~500kHz 500kHz~5MHz 5MHz~30MHz Maximum RF Line Voltage (dBuV) Quasi-peak Level 66 ~ 56 *
56 60 Average Level 56 ~ 46 *
46 50 Remark: (1) *Decreasing linearly with logarithm of the frequency.
(2) The lower limit shall apply at the transition frequency. 3.2. Test Setup 3.3. Test Procedure The EUT system is connected to the power mains through a line impedance stabilization network (L.I.S.N.). This provides a 50ohm coupling impedance for the EUT system. Please refer the block diagram of the test setup and photographs. Both sides of AC line are checked to find out the maximum conducted emission. In order to find the maximum emission levels, the relative positions of equipment and all of the interface cables shall be changed according to FCC ANSI C63.10-2013 on Conducted Emission Measurement. The bandwidth of test receiver (ESCI) set at 9kHz. The frequency range from 150kHz to 30MHz is checked. 3.4. Test Data Please to see the following pages Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page13 of 52 Report No.: SZAWW180614005-02 Conducted Emission Test Data Test Site:
Operating Condition:
Test Specification:
Comment:
1# Shielded Room Keeping TX+ Charging Mode AC 240V, 60Hz for adapter Live Line Tem.: 23.7 Hum.: 53%
Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page14 of 52 Report No.: SZAWW180614005-02 Conducted Emission Test Data Test Site:
Operating Condition:
Test Specification:
Comment:
1# Shielded Room Keeping TX+ Charging Mode AC 240V, 60Hz for adapter Neutral Line Tem.: 23.7 Hum.: 53%
Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page15 of 52 Report No.: SZAWW180614005-02 Conducted Emission Test Data Test Site:
Operating Condition:
Test Specification:
Comment:
1# Shielded Room Keeping TX+ Charging Mode AC 120V, 60Hz for adapter Live Line Tem.: 23.7 Hum.: 53%
Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page16 of 52 Report No.: SZAWW180614005-02 Conducted Emission Test Data Test Site:
Operating Condition:
Test Specification:
Comment:
1# Shielded Room Keeping TX+ Charging Mode AC 120V, 60Hz for adapter Neutral Line Tem.: 23.7 Hum.: 53%
Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page17 of 52 Report No.: SZAWW180614005-02 4. Radiation Spurious Emission and Band Edge 4.1. Test Standard and Limit Test Standard FCC Part15 C Section 15.209 and 15.205 Test Limit Frequency
(MHz) Field strength
(microvolt/meter) Limit
(dBuV/m) Remark Measurement distance (m) 0.009MHz~0.490MHz 2400/F(kHz) 0.490MHz-1.705MHz 24000/F(kHz) 1.705MHz-30MHz 30MHz~88MHz 88MHz~216MHz 216MHz~960MHz 960MHz~1000MHz Above 1000MHz 30 100 150 200 500 500
-
-
-
-
40.0 43.5 46.0 54.0 54.0 74.0
-
-
-
Quasi-peak Quasi-peak Quasi-peak Quasi-peak Average Peak 300 30 30 3 3 3 3 3 3 Remark:
(1)The lower limit shall apply at the transition frequency.
(2) 15.35(b), Unless otherwise specified, the limit on peak radio frequency emissions is 20dB above the maximum permitted average emission limit applicable to the equipment under test. This peak limit applies to the total peak emission level radiated by the device. 4.2. Test Setup Figure 1. Below 30MHz Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page18 of 52 Report No.: SZAWW180614005-02 Figure 2. 30MHz to 1GHz Figure 3. Above 1 GHz 4.3. Test Procedure For below 1GHz: The EUT is placed on a turntable, which is 0.8m above the ground plane. For above 1GHz: The EUT is placed on a turntable, which is 1.5m above the ground plane. The turn table can rotate 360 degrees to determine the position of the maximum emission level. The EUT is set 3 meters away from the receiving antenna which is mounted on a antenna tower. The antenna can be moved up and down from 1 to 4 meters to find out the maximum emission level. Rotated the EUT through three orthogonal axes to determine the maximum emissions, both horizontal and vertical polarization of the antenna are set on test. The EUT is tested in 9*6*6 Chamber. The device is evaluated in xyz orientation. For the radiated emission test above 1GHz:
Place the measurement antenna away from each area of the EUT determined to be a source of emissions at the specified measurement distance, while keeping the measurement antenna aimed at the source of emissions at each frequency of significant emissions, with polarization oriented for maximum response. The measurement antenna may have to be higher or lower than the EUT, depending on the radiation pattern of the emission and staying Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page19 of 52 Report No.: SZAWW180614005-02 aimed at the emission source for receiving the maximum signal. The final measurement antenna elevation shall be that which maximizes the emissions. The measurement antenna elevation for maximum emissions shall be restricted to a range of heights of from 1 m to 4 m above the ground or reference ground plane. For 9kHz to 150kHz, Set the spectrum analyzer as:
RBW = 200Hz, VBW =1kHz, Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto couple. For 150kHz to 30MHz, Set the spectrum analyzer as:
RBW = 9KHz, VBW =30kHz, Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto couple. For 30MHz to 1000MHz, Set the spectrum analyzer as:
RBW = 100kHz, VBW =300kHz,Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto couple. For above 1GHz,Set the spectrum analyzer as:
RBW =1MHz, VBW =1MHz, Detector= Peak, Trace mode= Max hold, Sweep- auto couple. RBW =1MHz, VBW =10Hz, Detector= Average, Trace mode= Max hold, Sweep- auto couple. 4.4. Test Data PASS During the test, Pre-scan all kind of the place mode (X-axis, Y-axis, Z-axis), and found the X-axis is the worst case. The test results of 9kHz-30MHz was attenuated more than 20dB below the permissible limits, so the results don't record in the report. Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page20 of 52 Report No.: SZAWW180614005-02 Test Results (30~1000MHz) Job No.:
Standard:
SZAWW180614005-02 Temp.()/Hum.(%RH):
24/51%RH FCC PART 15C Power Source:
DC 11.1V Battery inside Test Mode:
Keeping TX+ Charging Mode Polarization:
Horizontal Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page21 of 52 Report No.: SZAWW180614005-02 Test Results (30~1000MHz) Job No.:
Standard:
SZAWW180614005-02 Temp.()/Hum.(%RH):
24/51%RH FCC PART 15C Power Source:
DC 11.1V Battery inside Test Mode:
Keeping TX+ Charging Mode Polarization:
Vertical Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page22 of 52 Report No.: SZAWW180614005-02 Test Results (1GHz-25GHz) Test Mode: CH00 Frequency
(MHz) Read Level
(dBuV) 4804.00 7206.00 9608.00 12010.00 14412.00 4804.00 7206.00 9608.00 12010.00 14412.00 38.45 32.59 32.15
*
*
42.97 34.45 31.68
*
*
Frequency
(MHz) Read Level
(dBuV) 4804.00 7206.00 9608.00 12010.00 14412.00 4804.00 7206.00 9608.00 12010.00 14412.00 27.05 21.15 20.15
*
*
31.40 23.40 19.98
*
*
Test channel: Lowest Peak Value Preamp Factor
(dB) 34.09 34.50 34.79 34.09 34.50 34.79 Cable Loss
(dB) 6.58 7.73 9.23 6.58 7.73 9.23 Average Value Cable Loss
(dB) 6.58 7.73 9.23 6.58 7.73 9.23 Preamp Factor
(dB) 34.09 34.50 34.79 34.09 34.50 34.79 Antenna Factor
(dB/m) 34.04 37.11 39.31 34.04 37.11 39.31 Antenna Factor
(dB/m) 34.04 37.11 39.31 34.04 37.11 39.31 Level
(dBuV/m) Limit
(dBuV/m) Over Limit
(dB) Pol. 44.98 42.93 45.90 49.50 44.79 45.43 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00
-29.02
-31.07
-28.10
-24.50
-29.21
-28.57 V V V V V H H H H H Level
(dBuV/m) Limit
(dBuV/m) Over Limit
(dB) Pol. 33.58 31.49 33.90 37.93 33.74 33.73 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00
-20.42
-22.51
-20.10
-16.07
-20.26
-20.27 V V V V V H H H H H Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page23 of 52 Report No.: SZAWW180614005-02 Test Results (1GHz-25GHz) Test Mode: CH19 Frequency
(MHz) Read Level
(dBuV) 4880.00 7320.00 9760.00 12200.00 14640.00 4880.00 7320.00 9760.00 12200.00 14640.00 36.83 31.52 31.19
*
*
41.02 33.23 30.57
*
*
Frequency
(MHz) Read Level
(dBuV) 4880.00 7320.00 9760.00 12200.00 14640.00 4880.00 7320.00 9760.00 12200.00 14640.00 25.75 20.26 19.37
*
*
29.93 22.41 19.06
*
*
Test channel: Middle Peak Value Preamp Factor
(dB) 34.09 34.53 34.80 34.09 34.53 34.80 Cable Loss
(dB) 6.69 7.78 9.35 6.69 7.78 9.35 Average Value Cable Loss
(dB) 6.69 7.78 9.35 6.69 7.78 9.35 Preamp Factor
(dB) 34.09 34.53 34.80 34.09 34.53 34.80 Antenna Factor
(dB/m) 34.38 37.22 39.46 34.38 37.22 39.46 Antenna Factor
(dB/m) 34.38 37.22 39.46 34.38 37.22 39.46 Level
(dBuV/m) Limit
(dBuV/m) Over Limit
(dB) Pol. 43.81 41.99 45.20 48.00 43.70 44.58 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00
-30.19
-32.01
-28.80
-26.00
-30.30
-29.42 V V V V V H H H H H Level
(dBuV/m) Limit
(dBuV/m) Over Limit
(dB) Pol. 32.73 30.73 33.38 36.91 32.88 33.07 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00
-21.27
-23.27
-20.62
-17.09
-21.12
-20.93 V V V V V H H H H H Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page24 of 52 Report No.: SZAWW180614005-02 Test Results (1GHz-25GHz) Test Mode: CH39 Frequency
(MHz) Read Level
(dBuV) 4960.00 7440.00 9920.00 12400.00 14880.00 4960.00 7440.00 9920.00 12400.00 14880.00 36.41 31.23 30.94
*
*
40.51 32.91 30.27
*
*
Frequency
(MHz) Read Level
(dBuV) 4960.00 7440.00 9920.00 12400.00 14880.00 4960.00 7440.00 9920.00 12400.00 14880.00 25.45 20.06 19.19
*
*
29.59 22.18 18.85
*
*
Test channel: Highest Peak Value Preamp Factor
(dB) 34.09 34.57 34.81 34.09 34.57 34.81 Cable Loss
(dB) 6.79 7.82 9.46 6.79 7.82 9.46 Average Value Cable Loss
(dB) 6.79 7.82 9.46 6.79 7.82 9.46 Preamp Factor
(dB) 34.09 34.57 34.81 34.09 34.57 34.81 Antenna Factor
(dB/m) 34.72 37.34 39.62 34.72 37.34 39.62 Antenna Factor
(dB/m) 34.72 37.34 39.62 34.72 37.34 39.62 Level
(dBuV/m) Limit
(dBuV/m) Over Limit
(dB) Pol. 43.83 41.82 45.21 47.93 43.50 44.54 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00
-30.17
-32.18
-28.79
-26.07
-30.50
-29.46 V V V V V H H H H H Level
(dBuV/m) Limit
(dBuV/m) Over Limit
(dB) Pol. 32.87 30.65 33.46 37.01 32.77 33.12 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00
-21.13
-23.35
-20.54
-16.99
-21.23
-20.88 V V V V V H H H H H Remark:
1. Level =Receiver Read level + Antenna Factor + Cable Loss Preamplifier Factor 2. * means the test results were attenuated more than 20dB below the permissible limits, so the results don't record in the report. Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page25 of 52 Report No.: SZAWW180614005-02 Radiated Band Edge:
Test Mode: CH00 Test channel: Lowest Frequency
(MHz) Read Level
(dBuV) 2390.00 2400.00 2390.00 2400.00 46.55 63.87 47.45 66.30 Frequency
(MHz) Read Level
(dBuV) 2390.00 2400.00 2390.00 2400.00 36.27 47.73 36.48 44.73 Antenna Factor
(dB/m) 29.15 29.16 29.15 29.16 Antenna Factor
(dB/m) 29.15 29.16 29.15 29.16 Peak Value Preamp Factor
(dB) 34.01 34.01 34.01 34.01 Cable Loss
(dB) 3.41 3.43 3.41 3.43 Average Value Cable Loss
(dB) 3.41 3.43 3.41 3.43 Preamp Factor
(dB) 34.01 34.01 34.01 34.01 Level
(dBuV/m) Limit
(dBuV/m) Over Limit
(dB) Pol. 45.10 62.45 46.00 64.88 74.00 74.00 74.00 74.00
-28.90
-11.55
-28.00
-9.12 H H V V Level
(dBuV/m) Limit
(dBuV/m) Over Limit
(dB) Pol. 34.82 46.31 35.03 43.31 54.00 54.00 54.00 54.00
-19.18
-7.69
-18.97
-10.69 H H V V Test Mode: CH39 Test channel: Highest Frequency
(MHz) Read Level
(dBuV) 2483.50 2500.00 2483.50 2500.00 49.09 47.57 50.55 48.91 Frequency
(MHz) Read Level
(dBuV) 2483.50 2500.00 2483.50 2500.00 39.14 36.62 40.66 36.85 Antenna Factor
(dB/m) 29.28 29.30 29.28 29.30 Antenna Factor
(dB/m) 29.28 29.30 29.28 29.30 Peak Value Preamp Factor
(dB) 34.03 34.03 34.03 34.03 Cable Loss
(dB) 3.53 3.56 3.53 3.56 Average Value Cable Loss
(dB) 3.53 3.56 3.53 3.56 Preamp Factor
(dB) 34.03 34.03 34.03 34.03 Level
(dBuV/m) Limit
(dBuV/m) Over Limit
(dB) Pol. 47.87 46.40 49.33 47.74 74.00 74.00 74.00 74.00
-26.13
-27.60
-24.67
-26.26 H H V V Level
(dBuV/m) Limit
(dBuV/m) Over Limit
(dB) Pol. 37.92 35.45 39.44 35.68 54.00 54.00 54.00 54.00
-16.08
-18.55
-14.56
-18.32 H H V V Remark:
1. Level =Receiver Read level + Antenna Factor + Cable Loss Preamplifier Factor Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page26 of 52 Report No.: SZAWW180614005-02 5. Maximum Peak Output Power Test 5.1. Test Standard and Limit FCC Part15 C Section 15.247 (b)(3) 30dBm Test Standard Test Limit 5.2. Test Setup 5.3. Test Procedure This procedure shall be used when the measurement instrument has available a resolution bandwidth that is greater than the DTS bandwidth. 1. Set the RBW DTS bandwidth. 2. Set the VBW3*RBW. 3. Set the span 3*RBW. 4. Detector = peak. 5. Sweep time = auto couple. 6. Trace mode = max hold. 7. Allow trace to fully stabilize. 8. Use peak marker function to determine the peak amplitude level. 5.4. Test Data Test Item Test Voltage Test Result Max. peak output power DC 11.1V Battery inside PASS
: CH Low ~ CH High
:
:
Test Mode Temperature Humidity 24 55%RH
:
:
:
Channel Frequency Peak Power output
(MHz) 2402 2440 2480
(dBm)
-0.360
-0.057
-0.840 Limit
(dBm) 30 30 30 Results PASS PASS PASS Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page27 of 52 Report No.: SZAWW180614005-02 CH: Low CH: Middle Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page28 of 52 Report No.: SZAWW180614005-02 CH: High Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page29 of 52 Report No.: SZAWW180614005-02 6. 6DB Occupy Bandwidth Test 6.1. Test Standard and Limit Test Standard Test Limit FCC Part15 C Section 15.247 (a)(2)
>500kHz 6.2. Test Setup 6.3. Test Procedure 1. Place the EUT on the table and set it in the transmitting mode. 2. Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to the spectrum analyzer. 3. Set the spectrum analyzer as:
RBW = 100kHz, VBW3*RBW =300kHz, Detector= Peak Trace mode= Max hold. Sweep- auto couple. 4. Mark the peak frequency and 6dB (upper and lower) frequency. 5. Repeat until all the rest channels are investigated. 6.4. Test Data Test Item Test Voltage Test Result 6dB Bandwidth DC 11.1V Battery inside PASS
:
:
:
Test Mode Temperature Humidity Channel Frequency(MHz) Bandwidth (kHz) Low Middle High 2402 2440 2480 666.2 674.8 682.7
: CH Low ~ CH High
:
:
24 55%RH Limit
(kHz)
>500 Results PASS PASS PASS Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page30 of 52 Report No.: SZAWW180614005-02 CH: Low CH: Middle Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page31 of 52 Report No.: SZAWW180614005-02 CH: High Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page32 of 52 Report No.: SZAWW180614005-02 7. Power Spectral Density Test 7.1. Test Standard and Limit Test Standard Test Limit FCC Part15 C Section 15.247 (e) 8dBm 7.2. Test Setup 7.3. Test Procedure 1. Place the EUT on the table and set it in transmitting mode. Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to the spectrum analyzer. 2. Set the spectrum analyzer as RBW = 3kHz, VBW = 10kHz, Span = 1.5xDTS BW 3. Record the max. reading. 4. Repeat the above procedure until the measurements for all frequencies are completed. 7.4. Test Data Test Item Test Voltage Test Result Power Spectral Density DC 11.1V Battery inside PASS Test Mode Temperature Humidity
:
:
:
: CH Low ~ CH High
:
:
24 55%RH Channel Low Middle High Frequency
(MHz) 2402 2440 2480 PPSD
(dBm/KHz)
-13.267
-12.879
-13.818 Limit
(dBm/3KHz) 8.00 8.00 8.00 Results PASS PASS PASS Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page33 of 52 Report No.: SZAWW180614005-02 CH: Low CH: Middle Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page34 of 52 Report No.: SZAWW180614005-02 CH: High Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page35 of 52 Report No.: SZAWW180614005-02 8. 100kHz Bandwidth of Frequency Band Edge Requirement 8.1. Test Standard and Limit Test Standard FCC Part15 C Section 15.247 (d) in any 100 kHz bandwidth outside the frequency bands in which the spread spectrum intentional radiator in operating, the radio frequency power that is produced by the intentional radiator shall be at least 20dB below that in the 100kHz bandwidth within the band that contains the highest level of the desired power, In addition, radiated emissions which fall in the restricted bands, as defined in 15.205(a), must also comply with the radiated emission limits specified in15.209(a). Test Limit 8.2. Test Setup 8.3. Test Procedure Using the following spectrum analyzer setting:
1. Set the RBW = 100KHz. 2. Set the VBW = 300KHz. 3. Sweep time = auto couple. 4. Detector function = peak. 5. Trace mode = max hold. 6. Allow trace to fully stabilize. 8.4. Test Data Test Item Test Voltage Test Result
:
:
:
Band edge DC 11.1V Battery inside PASS Test Mode Temperature Humidity
:
:
:
CH Low ~ CH High 24 55%RH Frequency Band Delta Peak to Band Emission
(MHz) 2400 2483.5
(dBc) 55.071 58.669 Limit
(dBc)
>20
>20 Results PASS PASS Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page36 of 52 Report No.: SZAWW180614005-02 CH: Low CH: High Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page37 of 52 Report No.: SZAWW180614005-02 Conducted Emission Method CH: Low CH: Middle Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page38 of 52 Report No.: SZAWW180614005-02 CH: High Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page39 of 52 Report No.: SZAWW180614005-02 9. Antenna Requirement 9.1. Test Standard and Requirement Test Standard FCC Part15 Section 15.203 /247(c) Requirement 1) 15.203 requirement:
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited. 2) 15.247(c) (1)(i) requirement:
Systems operating in the 2400-2483.5 MHz band that fixed. Point-to-point operations may employ transmitting antennas with directional gain greater than 6dBi provided the maximum conducted output power of the intentional radiator is reduced by 1 dB for every 3 dB that the directional gain of the antenna exceeds 6 dBi. is used exclusively for 9.2. Antenna Connected Construction The BT antenna is a PCB Antenna which permanently attached, and the best case gain of the antenna is 0 dBi. It complies with the standard requirement. BT Antenna Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page40 of 52 Report No.: SZAWW180614005-02 APPENDIX I -- TEST SETUP PHOTOGRAPH Photo of Conducted Emission Measurement Photo of Radiation Emission Test Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page41 of 52 Report No.: SZAWW180614005-02 Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page42 of 52 Report No.: SZAWW180614005-02 APPENDIX II -- EXTERNAL PHOTOGRAPH Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page43 of 52 Report No.: SZAWW180614005-02 Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page44 of 52 Report No.: SZAWW180614005-02 Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page45 of 52 Report No.: SZAWW180614005-02 Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page46 of 52 Report No.: SZAWW180614005-02 Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page47 of 52 Report No.: SZAWW180614005-02 APPENDIX III -- INTERNAL PHOTOGRAPH Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page48 of 52 Report No.: SZAWW180614005-02 Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page49 of 52 Report No.: SZAWW180614005-02 Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page50 of 52 Report No.: SZAWW180614005-02 Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page51 of 52 Report No.: SZAWW180614005-02 Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com Shenzhen Anbotek Compliance Laboratory Limited FCC ID: 2ANI8-TURTLEBOX Page52 of 52 Report No.: SZAWW180614005-02
---------------- End of Report ----------------
Shenzhen Anbotek Compliance Laboratory Limited Tel:(86)755-26066440 Fax:(86)755-26014772 www.anbotek.com
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2018-07-19 | 2402 ~ 2480 | DTS - Digital Transmission System | Original Equipment |
2 | 2402 ~ 2480 | DSS - Part 15 Spread Spectrum Transmitter |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 | Effective |
2018-07-19
|
||||
1 2 | Applicant's complete, legal business name |
UNITEIC COMPANY LIMITED
|
||||
1 2 | FCC Registration Number (FRN) |
0026789909
|
||||
1 2 | Physical Address |
Gaolong Industrial, Huanzhuli Village, Changping Town Dongguan Guangdong, China.
|
||||
1 2 |
Gaolong Industrial, Huanzhuli Village
|
|||||
1 2 |
Dongguan, N/A
|
|||||
1 2 |
China
|
|||||
app s | TCB Information | |||||
1 2 | TCB Application Email Address |
j******@metlabs.com
|
||||
1 2 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 2 | Grantee Code |
2ANI8
|
||||
1 2 | Equipment Product Code |
TURTLEBOX
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 | Name |
w****** c****
|
||||
1 2 | Title |
Manager
|
||||
1 2 | Telephone Number |
15976********
|
||||
1 2 | Fax Number |
0755-********
|
||||
1 2 |
3******@qq.com
|
|||||
app s | Technical Contact | |||||
1 2 | Firm Name |
Shenzhen Anbotek Compliance Laboratory Limited
|
||||
1 2 | Name |
T**** C******
|
||||
1 2 | Physical Address |
1/F, Building D,Sogood Science and Technology Park
|
||||
1 2 |
Shenzhen, Guangdong
|
|||||
1 2 |
China
|
|||||
1 2 | Telephone Number |
86755********
|
||||
1 2 | Fax Number |
86755********
|
||||
1 2 |
t******@anbotek.com
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 2 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 | Equipment Class | DTS - Digital Transmission System | ||||
1 2 | DSS - Part 15 Spread Spectrum Transmitter | |||||
1 2 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | TURTLE BOX | ||||
1 2 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 | Modular Equipment Type | Does not apply | ||||
1 2 | Purpose / Application is for | Original Equipment | ||||
1 2 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | Yes | ||||
1 2 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 | Grant Comments | Output Power listed is peak conducted. | ||||
1 2 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 | Firm Name |
Shenzhen Anbotek Compliance Laboratory Limited
|
||||
1 2 | Name |
J******** Z********
|
||||
1 2 | Telephone Number |
86-75********
|
||||
1 2 | Fax Number |
86-75********
|
||||
1 2 |
j******@anbotek.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | CC | 2402.00000000 | 2480.00000000 | 0.0010000 | |||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 15C | CC | 2402.00000000 | 2480.00000000 | 0.0006000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC