Doc. Title Originator Date Version UNA Plus/ UNA-Lite Function EVB User Guide Max Shu 2013.10.29 V1.2 Product Line Doc. NO. CONFIDENTIAL Low Normal High UMD (MPC) The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. Revision Record Version Revise content 1.1 Initial Release Date 2013.06.06 The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 1 Category 1. FCC Regulations ....................................................................................3 2. R&TTE Regulations ..............................................................................4 3. RF Exposure Information......................................................................5 4. Information of Installed Module...........................................................6 5. Illustration of Function EVB.................................................................7 6. General Mode .........................................................................................9 6-1 Setting of Jumpers & Switches .............................................................9 7. Settings for Download /Update Mode.................................................14 8. Advance Mode......................................................................................15 8-1 Module on/off Control...........................................................................15 8-2 Voltage Settings ....................................................................................15 8-3 Use External Power Supplier...............................................................16 8-4 Current Measurement...........................................................................17 8-5 Settings for Slide-Style Switch (J42)...................................................17 8-6 PCM Signal ............................................................................................18 8-6-1 PCM Signal Port (J24)................................................................................................................... 18 8-6-2 PCM Loop Settings........................................................................................................................ 19 8-6-3 External I2C Interface to Control Audio Codec .............................................................................. 20 8-7 UART0 & UART1 Signal Port (J23)......................................................21 8-8 Wakeup Control ....................................................................................22 8-8-1 USB Mode ..................................................................................................................................... 22 8-8-2 USB+UART Mode ......................................................................................................................... 23 The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 2 1. FCC Regulations
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiated radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Connect the equipment into an outlet on a circuit different from that to Increase the separation between the equipment and receiver. which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help. The maximum antenna gain for frequency 900 is 2 dBi; for frequency 1800 is 2 dBi ;and the antenna separation distance is 20cm. Maximum antenna gain allowed for use with this device is 2 dBi. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 3 2. R&TTE Regulations In all cases assessment of the final product must be mass against the Essential requirements of the R&TTE Directive Articles 3.1(a) and (b), safety and EMC respectively, as well as any relevant Article 3.3 requirements. 1. Health (Article 3.1(a) of the R&TTE Directive) Applied Standard(s):
EN62311:2008 2. Safety (Article 3.1(a) of the R&TTE Directive) Applied Standard(s):
EN 60950-1:2006/A11:2009/A1:2010/A12:2011 3. Electromagnetic compatibility (Article 3.1 (b) of the R&TTE Directive) Applied Standard(s):
EN 301 489-1 V1.9.2/-7 V1.3.1/-24 V1.5.1 4. Radio frequency spectrum usage (Article 3.2 of the R&TTE Directive) Applied Standard(s):
EN 301 511 V9.0.2 EN 301 908-1 V5.2.1/ -2 V5.2.1 The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 4 3. RF Exposure Information Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This device is intended only for OEM integrators under the following conditions:
1) The antenna must be installed such that 20 cm is maintained between the antenna and users 2) The transmitter module may not be co-located with any other transmitter or antenna. As long as 2 conditions above are met, further transmitter test will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed IMPORTANT NOTE: In the event that these conditions can not be met (for example certain laptop configurations or co-location with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID can not be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC authorization. End Product Labeling This transmitter module is authorized only for use in device where the antenna may be installed such that 20 cm may be maintained between the antenna and users. The final end product must be labeled in a visible area with the following: Contains FCC ID: IXM-UNA-P3. The grantee's FCC ID can be used only when all FCC compliance requirements are met. Manual Information To the End User The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the users manual of the end product which integrates this module. The end user manual shall include all required regulatory information/warning as show in this manual. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 5 4. Information of Installed Module Module Name HW Version SW Version GSM Band UMTS Band GSM Feature GPRS EDGE UMTS Feature AT Command SIM/USIM Interface Operating Temperature UNA-P3/UNA-L3 V21 V2.4.00101 850, 900, 1800, 1900 FDD I, FDD II, FDD V R99 Class 12 Class 12 HSDPA, HSUPA,HSPA+(R7) 3GPP TS 27.007, 27.005 Support 3V and 1.8V USB 2.0 high speed Frequency Stability covers operating temperature range of -20 to +50C Operating Voltage 3.4 ~ 4.2V The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 6 User Guide for UNA PLUS Function EVB 5. Illustration of Function EVB Figure. Layout of Function EVB The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 7 Description Support Non-Support Reference Type USB Conn. Pin Header Pin Header Pin Header Module on/off control (Default is Open.) Main antenna SMA Connector AUX antenna SMA Connector Debug Pin Transmit/ Receive AT Command. Factory Test (Default is Open.) UART0 & UART1 signal connector
(Default is Open.) Factory Test (Default is Open.) PCM signal connector (Default is Open.) Pin Header Ant. Conn. Ant. Conn. SIM 1 Conn. Connect SIM Card SIM 2 Conn. Connect SIM Card COM port 0 COM port 1 Pin Header J8 Connect host PC or download firmware Select external power supplier (+) J7
(Default is Open.) Select external power supply (-) J9
(Default is Open.) SW1 On/off switch Module on/off control J55 J15 J16 U24 U21 J18 J19 J21 J23 J30 J24 J56 J54 J2 J28 J29 J42 J52 J51 J57 J34 J35 J50 J22 J25 J26 Pin Header Pin Header Pin Header Wake up AP in AP sleep mode
(wake up AP) (Default is Open.) Pin Header Wake up module in module sleep mode
(wake up modem) (Default is Open.) Headset Conn. EAR PHONE & MIC Audio Conn. Audio Conn. Switch Conn. Slide-Style Switch. Pin Header Pin Header Pin Header Pin Header Pin Header Pin Header Pin Header Pin Header Pin Header Factory Test (Default is Open.) Factory Test (Default is Open.) Factory Test (Default is Open.) Factory Test (Default is Open.) Factory Test (Default is Open.) Factory Test (Default is Open.) Factory Test (Default is Open.) Factory Test (Default is Open.) Factory Test (Default is Open.) Audio LINE-OUT Audio LINE-IN V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 8 6. General Mode 6-1 Setting of Jumpers & Switches Step4 Step8 Step3 Step2 Step5 Step7 Step6 Figure. Settings of general mode Step1. Remove every jumper on the board. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 9 Step2. Keep R19 and R20 short. R19 R20 Step3. For SW1, select 1-2. (Upper position) Figure. Keep R19 and R20 short. Step4. For J42, eight switches should be in OFF position. Figure. For SW1, select 1-2. ON OFF Figure. Switches in OFF position. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 10 Step5. Insert SIM card. Step6. Set up Antenna. a. Connect bottom of mini card by U.FL cable as following photo. Figure. Insert correctly SIM card. b.Connect EVB and mini card by U.FL cable. Put mini card on EVB. Figure. Connect by U.FL cable. Figure. Connect mini card and EVB. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 11 b. Connect SMA antenna. Figure. Connect antenna. Step7. Set up Module. a. By 30 degree angle, le an mini card and insert it on the socket, J4. b. Press mini card until it is stuck Figure. Insert mini card. by connector, J5. Figure. Mini card is stuck. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 12 tep8. Connect computer by USB cable. S Recommended USB cable length is less tha n 60 mm. Figure. Connect PC by USB cable. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 13 7. Settings for Download /Update Mode Component reference Open/Short Function Pin17-18 in J25 Open Short Close Download/Update mode Start Download/Update mode Step1. Put back the jumper in J25 to short its Pin.17, Pin.18. Step2. Connect EVB and computer by USB cable. Figure. Put back jumper. Figure. Connect PC. Step3. About SW part, please refer to the file, UNA PLUS Flash Tool User Guide. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 14 8. Advance Mode 8-1 Module on/off Control a. Method 1. Module Control by SW1. Component reference Function SW1,1-2 Turn on (Default) SW1 Control Module PS2. Please remove the Jump, J55, at first. b. Method 2. Module Control by J55. Function Component reference Shut down (Default) Turn on Open Short Open/Short J55 SW1,2-3 Turn off PS3. Please select 2-3 for SW1 at first. (Lower position) J55 Figure. J55 & SW1 8-2 Voltage Settings Component reference J12 Open/Short Open Short Function Supply 3.3Volt to 3G Module. (Default) Supply 4.35Volt to 3G Module. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 15 8-3 Use External Power Supplier Please follow the steps as below. Step1. Remove the jumper, J10 and clear solder on R19. Step2. Connect host PC by USB cable. Step3. J7 is power input, and voltage range is from 3.3V to 4.3V. Step4. J9 is GND. Figure. J7, J9, J10 & J19 The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 16 8-4 Current Measurement Step1. Clear solder on R20. Step2. Measure two sides of J11. Figure. R20, J11 8-5 Settings for Slide-Style Switch (J42) Component reference Group ON Function Factory Test Factory Test Factory Test Factory Test OFF (Default) V V V V 1 2 3 4 5 6 7 8 J42 Control UART0 (J18) Control UART1 (J19) PCM signal select Factory Test Open UART0 port Open UART1 port Import to internal Audio codec V Close UART0 port Close UART1 port Export to external connector. (J24) In general mode, these eight switches should be set in OFF position. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 17 8-6 PCM Signal 8-6-1 PCM Signal Port (J24) Step1. Group.7 switch in J42 should be in ON position as follows. Step2. Please refer to the following photo to connect J24. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 18 Step3. Then, please confirm signal level. Default setting is 1.8V. If youd like 2.8V or 3.3V, please rework EVB by referring to following photos. R234:3.3V R229:2.8V R60:1.8V(Default) Figure. R20, J11 8-6-2 PCM Loop Settings Step1. Please follow 8-6-1. Step2. Put back the jumper in J24 to short its Pin.3 and Pin.5. Figure. J24 The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 19 8-6-3 External I2C Interface to Control Audio Codec Step1. Group.7 switch in J42 should be in OFF position as follows. Step2. AP could control modem by J25. J25.8 is SCL. J25.10 is SDA. Voltage level is 1.8V. Figure. J42 SCL SDA Figure. J25 Step3. About Codec init table, please refer to the file, UNA PLUS EVB Codec ReaTtek ALC5637Q Initial Table. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 20 8-7 UART0 & UART1 Signal Port (J23) Step1. Group.5 (for UART0) & Group.6 (for UART1) switches in J42 should be in ON position. UART0 UART1 Figure. Group5&6 switches in J42 Step2. Please refer to the following photo to connect J23. 2 4 6 8 10 1 3 5 7 9 Figure. Pin definition of J23 The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 21 Step3. Please confirm signal level. Default setting is 3.3V. If youd like 1.8V or 2.8V, please refer to the following photo to rework the EVB. Please put back R241 (default setting) before you use UART0 (J18) and UART1 (J19). R242:1.8V R239:2.8V R241:3.3V(Default) Figure. Voltage adjustment for UART. 8-8 Wakeup Control 8-8-1 USB Mode Please comply with the following procedures, from step 1 to step 3. Figure. USB Mode The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 22 8-8-2 USB+UART Mode Please comply with the following procedures, from step 1 to step 5. Operation Procedure Step1. Connect EVB & Host/AP by USB cable. Figure. USB+UART Mode Figure. Connect Host/AP & EVB Step2. Please refer to Section 4-1, Module on/off control, to start up modem. Step3. Connect AP/Host and EVB by J56, Signal WAKEUP AP. Voltage level is 1.8V. Figure. J56, Signal WAKEUP AP The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 23 Step4. Connect AP/Host and EVB by J54.1, Signal WAKEUP MODEM. Voltage level is 1.8V. J54.1 is marked in yellow circle in following picture. Figure. J54.1, Signal WAKEUP MODEM Step5. Please refer to Section 4-7, UART0 & UART1 Signal Port (J23), to About timing diagram, please refer to the file UNA PLUS IO application design connect UART port. notes. Figure. Positions of Pin VABT_M, USB+ and USB-. The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 24 Figure. Positions of POWERON (J25.1), WAKEUP AP (J25.3) and WAKEUP MODEM (J25.5). The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd. 25