all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 2 |
|
User Manual | Users Manual | 793.21 KiB | July 08 2019 | |||
1 2 |
|
Appendix B-Test Data for BLE V4.0 | Test Report | 910.53 KiB | July 08 2019 | |||
1 2 |
|
Confidentiality Request Letter | Cover Letter(s) | 69.35 KiB | July 08 2019 | |||
1 2 |
|
External Photos | External Photos | 1.09 MiB | July 08 2019 | |||
1 2 |
|
Internal Photos | Internal Photos | 440.00 KiB | July 08 2019 | |||
1 2 |
|
LCS190702116AEB report-DTS | Test Report | 749.32 KiB | July 08 2019 | |||
1 2 |
|
Label and Label Location | ID Label/Location Info | 101.90 KiB | July 08 2019 | |||
1 2 |
|
Test Setup Photos | Test Setup Photos | 273.84 KiB | July 08 2019 | |||
1 2 | Test Report | June 08 2019 | ||||||
1 2 | Test Report | June 08 2019 |
1 2 | User Manual | Users Manual | 793.21 KiB | July 08 2019 |
SYDNEY
( M A N UA L) 1 LED ENGLISH (ENG) SPANISH (ES) FRENCH (FR A) GERMAN (DE) JAPANESE (JPN) KOREAN (KOR) 04 08 12 16 20 24 S Y D N E Y M A N U A L (SINGLE SPEAKER)
( E N G ) S Y D N E Y M A N U A L (TWO SPEAKERS)
( E N G ) CONNECT TO DEVICE Turn on the speaker via button and then turn on the Bluetooth on your device. Select Urbanista Syd-
ney. Upon successful pairing, the LED breathes white every 10 sec. If the speaker have been connected to a device before, it will automati-
cally go into pairing mode and con-
nect to the device when powered on. RESET PAIRING Press to disconnect the current device and search for a new device. Press again to reconnect to the previous device. BUTTON CONTROLS TURN ON/OFF - Hold for 3 seconds. PLAY/PAUSE MUSIC - Press once. VOLUME INCREASE - Press once. VOLUME DECREASE - Press once. PREVIOUS TRACK - Hold for 1 second. NEXT TRACK - Hold for 1 second. ANSWER/END A CALL - Press once. REFUSE A CALL - Hold for 1 second. USE SIRI - Press twice. PAIRING 2 SPEAKERS Turn on the speakers without being paired to any device. Hold the on both speakers for 1 sec-
ond until the LED indicators flash red and white. Upon successful pairing, you will hear a bip sound. LED on main speaker will flash white, and the second speaker will flash white every 10 second. CONNECT TO DEVICE When the speakers are ready to be connected to a device, turn on the Bluetooth in your device and choose Urbanista Sydney. Upon successful connection, both speakers LED lights will flash white every 10 seconds. Main speaker will act as left channel and the second speaker will act as right channel. DISCONNECT 2 SPEAKER MODE Press twice on either speaker. The main speaker will keep playing and the second will go into pairing mode. DISCONNECT DEVICE Press on the main speaker to discon-
nect the current and search for a new one. Press again to reconnect to the same device. 4 5 WA R R A N T Y / S A F E T Y I N S T R U C T I O N S
( E N G ) All Urbanista speakers are designed and manufactured to meet high expectations and to provide the best customer experience. We are devoted to producing only high quality items fea-
turing the latest technology. However, in exceptional cases, electronic products may have malfunctions due to manu-
facturing defects. That is why we offer a full one (1) year warranty from the date of original retail purchase, which covers defects in materials and workmanship. Urbanista AB hereby warrants that, under normal use, this product will be free from defects in materials and workman-
ship for a period of one (1) year starting with the original retail purchase date. The replacement warranty is valid only if the original proof of purchase issued to the purchaser, specifying the date of purchase, is presented with the prod-
uct to be replaced. How does it work? If you believe this product is defective, carefully repack the unit and return the product to your au-
thorized dealer within the warranty period, with the original proof of purchase. Your authorized dealer will replace the product, provided a defect in materials or workmanship is identified. Should your authorized dealer not have the equiv-
alent product or color in stock, Urbanista AB will promptly provide you with a new product. This limited replacement warranty does not apply in cases of abuse or misuse of the product, use contrary to the Ur-
banista AB instructions, ordinary wear and tear, incorrect connection, force majeure or unauthorized repair. Any law-
suit for breach of this limited warranty shall be commenced, if at all, within one (1) year of the date that the claim accrues. Urbanista AB shall not be liable for special, indirect, incidental or consequential damages resulting from the use or the inabil-
ity to use this product, regardless of the legal theory on which the claim is based. This warranty gives you specific legal rights, and you may have other rights, which vary from country to country. This warranty does not restrict the rights of the consumer mandated under applicable laws. This product shall not be treated as house-
hold waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. This product was produced after April 1st, 2019. WARNINGS Not suitable for children under age three: it contains small parts which may be a choking hazard. Choose a low volume setting before using the speaker. Long-term exposure to loud music or sounds may cause hearing damage. It is best to avoid high volume levels when using this product, especially for extended periods. CAUTIONS Using these speaker limits your ability to hear noises around you, regardless of listening volume. Please be cau-
tious when using these speakers. Do not drop, sit on, or allow the speakers to be immersed in water. For any questions or concerns contact:
support@urbanista.com 6 WA R R A N T Y / S A F E T Y I N S T R U C T I O N S FCC Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential instal-
lation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interfer-
ence will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
( E N G )
- Consult the dealer or an experienced radio/TV technician for help. When test standard is FCC section 15.247 or 15.407 (such Blue-
tooth, Wifi) Mobile Device
(a device designed to generally be used at a separation distance of at least 20 centimeters is normally maintained between the trans-
mitters radiating structure(s) and the body of the user) FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm be-
tween the radiator and your body. This transmitter must not be co-located or operating in conjunc-
tion with any other antenna or transmitter. Portable Device (a device designed to generally be used at a sep-
aration distance of within 20 centimeters is normally maintained between the transmitters radiating structure(s) and the body of the user). FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunc-
tion with any other antenna or transmitter. 7 M A N U A L D E S Y D N E Y (ALTAVOZ NICO)
( E S ) M A N U A L D E B R I S B A N E (DOBLE ALTAVOZ)
( E S ) CONECTAR AL DISPOSITIVO Encienda el altavoz con el botn B y active el Bluetooth en su dispositi-
vo. Seleccione Urbanista Sydney. Cuando estn vinculados, el LED emitir una luz blanca cada 10 se-
gundos. Si el altavoz ya estuvo conectado a un dispositivo, el modo vinculacin se activar automticamente y se conectar al dispositivo cuando se encienda. RESTABLECER VINCULACIN Presione para desconectar el dis-
positivo actual y buscar un dispositi-
vo nuevo. Presione nuevamente para reconectar al dispositivo anterior. CONTROLES DE LOS BOTONES ENCENDER/APAGAR: Mantenga presionado B durante 3 segundos. REPRODUCIR/PAUSAR LA MSICA: Presi-
one B una vez. SUBIR EL VOLUMEN: Presione B una vez. BAJAR EL VOLUMEN: Presione B una vez. CANCIN ANTERIOR: Mantenga presiona-
do B durante 1 segundo. CANCIN SIGUIENTE: Mantenga presio-
nado B durante 1 segundo. CONTESTAR/CORTAR UNA LLAMADA:
Presione B una vez. RECHAZAR UNA LLAMADA: Mantenga presionado B durante 1 segundo. USAR SIRI: Presione B dos veces. 8 VINCULAR 2 ALTAVOCES Encienda los altavoces sin vincularlos a ningn dispositivo. Mantenga presionado B en ambos al-
tavoces durante 1 segundo, hasta que los indicadores LED parpadeen con una luz roja y blanca. Una vez que se hayan vinculado correctamente, se escuchar un bip. El LED del altavoz principal parpadear con una luz blanca y el del segundo altavoz parpadear con una luz blanca cada 10 segundos. DESCONECTAR EL MODO DOBLE ALTAVOZ Presione B dos veces en cada altavoz. El altavoz principal seguir reproduci-
endo sonido y el segundo cambiar a modo vinculacin. CONECTAR AL DISPOSITIVO Cuando los altavoces estn listos para conectarse a un dispositivo, active el Bluetooth en su dispositivo y elija Ur-
banista Sydney. Una vez que se hayan conectado, las luces LED de ambos altavoces parpadearn una luz blanca cada 10 segundos. El altavoz principal funcionar como el canal izquierdo y el segundo altavoz funcionar como el canal derecho. DESCONECTAR EL DISPOSITIVO Presione B en el altavoz principal para desconectar el dispositivo actual y buscar otro. Vuelva a presionar el botn para reconectar el mismo dispositivo. 9 G A R A N T A
( E S ) I N S T R U C C I O N E S D E S E G U R I D A D
( E S ) Cada altavoz Urbanista fue diseado y fabricado para satisfacer las expectativas ms exigentes y lograr la total satisfaccin del cliente. Estamos comprometidos con fabricar nicamente pro-
ductos de primera calidad con la ltima tecnologa. Sin embargo, en casos excepcionales, es posible que nues-
tros productos electrnicos funcionen incorrectamente a causa de defectos de fabricacin. Por esta razn, ofrec-
emos un (1) ao completo de garanta desde la fecha de compra original en la tienda minorista que cubre defectos en los materiales y en la mano de obra. Urbanista AB garantiza por la presente que, si se le da un uso normal, este producto no tendr defectos de ma-
teriales ni de mano de obra por un perodo de un (1) ao desde la fecha de compra original en la tienda minorista. La garanta de reemplazo es vlida solo si se presenta el comprobante de compra original que se le entreg al comprador, con la fecha de compra especificada, junto con el producto que se reemplazar. Cmo funciona? Si cree que el producto est defectu-
oso, vuelva a empacar la unidad cuidadosamente y ent-
regue el producto a un distribuidor autorizado dentro del perodo de garanta, con el comprobante de compra orig-
inal. El distribuidor autorizado reemplazar el producto si se identifica un defecto de materiales o de mano de obra. Si el distribuidor autorizado no tiene el producto o color equivalente en existencias, Urbanista AB proporcionar un nuevo producto. Esta garanta de reemplazo limitada no aplica en casos de maltrato o uso incorrecto del producto, uso contrario a las instrucciones de Urbanista AB, desgaste normal, conex-
in incorrecta, fuerza mayor o reparacin no autorizada. Cualquier accin legal por incumplimiento de esta garanta limitada deber interponerse, de realizarse, dentro de un
(1) ao desde la fecha en que se realiz la reclamacin. Urbanista AB no ser responsable por los daos especiales, indirectos, fortuitos o consecuentes que resulten del uso o la incapacidad de uso de este producto, independiente-
mente de la teora jurdica en la que se base la reclamacin. Esta garanta le otorga derechos legales especficos y es posible que usted tenga otros derechos que varan segn el pas. Esta garanta no restringe los derechos del con-
sumidor establecidos por las leyes vigentes. Este producto no se tratar como un residuo domstico. En cambio, se dejar en el punto de recoleccin de reciclado de equipos elctricos y electrnicos correspondiente. Este producto se fabric despus del 1 de abril de 2019. 10 WARNINGS Not suitable for children under age three: it contains small parts which may be a choking hazard. Choose a low volume setting before using the speaker. Long-term exposure to loud music or sounds may cause hearing damage. It is best to avoid high volume levels when using this product, especially for extended periods. CAUTIONS Using these speaker limits your ability to hear noises around you, regardless of listening volume. Please be cautious when using these speakers. Do not drop, sit on, or allow the speakers to be im-
mersed in water. For any questions or concerns contact:
support@urbanista.com 11 B R I S B A N E M A N U A L (ENCEINTE SIMPLE)
( F R A ) B R I S B A N E M A N U A L (ENCEINTES DOUBLES)
( F R A ) CONNEXION UN APPAREIL Mettez lenceinte en marche via le bouton B puis activez le Blue-
tooth sur votre appareil. Slection-
nez Urbanista Sydney . Une fois lappairage russi, la LED respire en blanc toutes les 10 secondes. Si lenceinte a dj t connecte un appareil, elle passe automa-
tiquement en mode appairage et se connecte lappareil la mise en marche. RINITIALISATION DE LAPPAIRAGE Appuyez sur B pour dconnecter lappareil actuel et rechercher un nouvel appareil. Appuyez nouveau sur B pour vous reconnecter lappareil prcdent. BOUTONS DE COMMANDE MARCHE/ARRT - Maintenez B pen-
dant 3 secondes. LECTURE/PAUSE DE LA MUSIQUE -
Appuyez une fois sur B AUGMENTATION DU VOLUME - Appuyez une fois sur B . DIMINUTION DU VOLUME - Appuyez une fois sur MORCEAU PRCDENT - Maintenez B pendant 1 seconde. MORCEAU SUIVANT - Maintenez B pendant 1 seconde. RPONSE / FIN DUN APPEL - Appuyez une fois sur B . REFUSER UN APPEL - Maintenez B pendant 1 seconde. USAR SIRI: Presione B dos veces. 12 APPAIRER 2 ENCEINTES Mettez les enceintes en marche sans les appairer aucun appareil. Maintenez le bouton B des deux en-
ceintes pendant 1 seconde jusqu ce que les LED clignotent en rouge et blanc. Une fois lappairage russi, vous entendez un bip. La LED de lenceinte principale clignote en blanc et celle de la deuxime enceinte clignote en blanc toutes les 10 secondes. CONNEXION UN APPAREIL Lorsque les enceintes sont prtes tre connectes un appareil, activez le Bluetooth sur votre appareil et choisis-
sez Urbanista Sydney . Une fois la connexion tablie, les LED des deux enceintes clignotent en blanc toutes les 10 secondes. Lenceinte principale joue le rle de ca-
nal gauche et la deuxime enceinte de canal droit. DCONNECTER LE MODE ENCEINTES DOUBLES Appuyez deux fois sur B sur lune ou lautre des enceintes. Lenceinte prin-
cipale continue de jouer et la seconde passe en mode appairage. DCONNECTER UN APPAREIL Appuyez sur le bouton B de lenceinte principale pour dconnecter lappareil actuel et en rechercher un nouveau. Ap-
puyez nouveau pour vous reconnecter au mme appareil. 13 G A R A N T I E
( F R A ) C O N S I G N E S D E S C U R I T
( F R A ) Toutes les enceintes Urbanista sont conues et fabri-
ques pour rpondre aux attentes les plus exigeantes et offrir la meilleure exprience client. quivalente en stock, Urbanista AB vous fournira un nou-
veau produit dans les meilleurs dlais. Nous sommes ddis produire uniquement des arti-
cles de haute qualit dots des dernires technologies. Toutefois, dans des cas exceptionnels, les produits lec-
troniques peuvent prsenter des dysfonctionnements dus des dfauts de fabrication. Cest pourquoi nous offrons une garantie complte dun (1) an compter de la date dachat dorigine, couvrant les dfauts de matriaux et de fabrication. Urbanista AB garantit par la prsente que, dans des con-
ditions normales dutilisation, ce produit sera exempt de dfauts de matriaux et de fabrication pendant une pri-
ode dun (1) an compter de la date dachat dorigine. La garantie de remplacement nest valable que si la preuve dachat originale dlivre lacheteur, indiquant la date dachat, est prsente avec le produit remplacer. Quel est le principe de fonctionnement ? Si vous pensez que ce produit est dfectueux, remballez soigneusement lappareil et renvoyez-le votre revendeur agr pendant la priode de garantie, avec la preuve dachat originale. Votre revendeur agr remplacera le produit si un dfaut de matriau ou de fabrication est identifi. Si votre reven-
deur agr ne dispose pas du produit ou de la couleur Cette garantie limite de remplacement ne sapplique pas en cas dabus ou de mauvaise utilisation du produit, dutil-
isation contraire aux instructions dUrbanista AB, dusure normale, de connexion incorrecte, de force majeure ou de rparation non autorise. Toute action en justice pour viola-
tion de cette garantie limite sera entame, le cas chant, dans un dlai dun (1) an compter de la date laquelle la rclamation a eu lieu. Urbanista AB ne peut pas tre tenue responsable de dom-
mages spciaux, indirects, accessoires ou conscutifs rsultant de lutilisation ou de limpossibilit dutiliser ce produit, quelle que soit la thorie lgale sur laquelle la r-
clamation est fonde. Cette garantie vous accorde des droits lgaux spcifiques et vous pouvez avoir dautres droits, qui varient dun pays lautre. Cette garantie ne limite pas les droits du con-
sommateur prescrits par les lois applicables. Ce produit ne doit pas tre trait avec les dchets mnagers. Au lieu de cela, il doit tre remis au point de collecte concern pour le recyclage des quipements lectriques et lectroniques. Ce produit a t fabriqu aprs le 1er avril 2019. 14 AVERTISSEMENTS Ne convient pas aux enfants de moins de trois ans :
contient des petites pices pouvant prsenter un ris-
que dtouffement. Choisissez un rglage de volume faible avant duti-
liser lenceinte. Une exposition prolonge une musique ou des sons forts peut causer des dommages auditifs. Il est prfrable dviter des niveaux de volume levs lors de lutilisation de ce produit, en particulier pendant de longues priodes. MISES EN GARDE Lutilisation de ces enceintes limite votre capacit entendre les bruits autour de vous, quel que soit le volume dcoute. Soyez prudent lorsque vous utilisez ces enceintes. Ne laissez pas tomber les enceintes, ne vous asseyez pas dessus et ne les plongez pas dans leau. Pour toute question ou proccupation, contactez :
support@urbanista.com 15 S Y D N E Y H A N D B U C H (EINZEL-LAUTSPRECHER)
( D E ) S Y D N E Y H A N D B U C H (DOPPEL-LAUTSPRECHER)
( D E ) MIT DEM GERT VERBINDEN Schalten Sie den Lautsprecher mit der Taste B ein und aktivieren Sie dann Bluetooth an Ihrem Gert. Whlen Sie Urbanista Sydney aus. Nach erfolgreicher Koppelung blinkt die LED alle 10 Sekunden wei. Wenn der Lautsprecher bereits zuvor mit einem Gert verbunden worden war, wechselt er nach dem Ein-
schalten automatisch in den Koppe-
lungsmodus und verbindet sich mit dem Gert. KOPPELUNG ZURCKSETZEN Drcken Sie auf B, um das aktu-
elle Gert zu trennen und nach ei-
nem anderen Gert zu suchen. Drcken Sie noch einmal auf B, um sich wieder mit dem vorherigen Gert zu verbinden. BEDIENTASTEN EIN/AUS-SCHALTEN - Halten Sie B 3 Sekunden lang gedrckt. MUSIK WIEDERGEBEN /WIEDERGABE UNTERBRECHEN Drcken Sie einmal auf B. LAUTER - Drcken Sie einmal auf B. LEISER - Drcken Sie einmal auf B. VORHERIGER TITEL - Halten Sie B 1 Sekunde lang gedrckt. NCHSTER TITEL - Halten Sie B 1 Sekunde lang gedrckt. ANRUF ANNEHMEN /BEENDEN - Drcken Sie einmal auf B. ANRUF ABLEHNEN - Halten Sie B 1 Sekunde lang gedrckt. SIRI VERWENDEN - Drcken Sie zweimal auf B. 16 KOPPELUNG VON 2 LAUTSPRECHERN Schalten Sie die Lautsprecher ein (sie drfen mit keinem Gert gekoppelt sein). Halten Sie B an beiden Lautspre-
chern 1 Sekunde lang gedrckt, bis die LED-Anzeigen rot und wei blinken. Der erfolgreiche Koppelungsvorgang wird mit einem Piepston besttigt. Die LED am Hauptlautsprecher blinkt wei, der zweite Lautsprecher blinkt alle 10 Sekunden wei. MIT DEM GERT VERBINDEN Wenn die Lautsprecher fr die Koppe-
lung mit einem Gert bereit sind, aktiv-
ieren Sie Bluetooth an Ihrem Gert und whlen Urbanista Sydney aus. Nach erfolgreicher Koppelung blinken die LED-Lampen an beiden Lautsprechern alle 10 Sekunden wei. Der Hauptlautsprecher fungiert als linker Kanal, der zweite Lautsprecher als rechter Kanal. DOPPEL-LAUTSPRECHERMODUS TRENNEN Drcken Sie an einem der Lautspre-
cher auf B. Der Hauptlautsprecher setzt die Wiedergabe fort, whrend der zweite Lautsprecher in den Koppelung-
smodus wechselt. GERT TRENNEN Drcken Sie am Hauptlautsprecher auf B, um das aktuelle Gert zu tren-
nen und nach einem anderen Gert zu suchen. Drcken Sie noch einmal auf B, um sich wieder mit dem vorherigen Gert zu verbinden. 17 G A R A N T I E
( D E ) S I C H E R H E I T S H I N W E I S E
( D E ) Alle Lautsprecher von Urbanista werden fr hchste Ansprche und optimierte Kundenerfahrung entwickelt und gefertigt. Unser Ziel ist es, nur hochwertige Artikel herzustellen, die ber die neuste Technologie verfgen. Allerdings knnen auch elektronische Produkte in Ausnahmefllen aufgrund von Fertigungsfehlern mngelbehaftet sein. Aus diesem Grund geben wir Ihnen ab dem ursprnglichen Kaufdatum eine einjhrige Garantie fr Material- und Verarbeitungsfehler. Urbanista AB garantiert damit, dass dieses Produkt un-
ter normalen Nutzungsbedingungen fr einen Zeitraum von einem (1) Jahr ab dem ursprnglichen Kaufdatum frei von Material- und Verarbeitungsfehlern ist. Die Er-
satzgarantie ist nur gltig, wenn gemeinsam mit dem umzutauschenden Produkt der fr den Kufer ausgestellte und datierte Orig-
inalkaufbeleg vorgelegt wird. Vorgehensweise zur Inanspruchnahme der Garantie Wenn Sie glauben, dass dieses Produkt defekt ist, packen Sie das Gert sorgfltig ein und bringen Sie es innerhalb der Garantiefrist, zusammen mit dem Originalkaufbeleg, zurck zu Ihrem offiziellen Fachhndler. Ihr offizieller Fachhndler wird das Produkt ersetzen, sofern ein Mate-
rial- oder Verarbeitungsfehler festgestellt wird. Sollte Ihr offizieller Fachhndler kein gleichwertiges oder -farbiges Produkt vorrtig haben, wird Urbanista AB Ihnen umgehend ein neues Produkt liefern. Diese beschrnkte Ersatzgarantie gilt nicht bei fehlerhafter oder missbruchlicher Verwendung des Produkts, Verwend-
ung entgegen den Anweisungen von Urbanista AB, nor-
malem Verschlei und Abnutzung, fehlerhaftem Anschluss, Hherer Gewalt oder unbefugten Reparaturversuchen. Jede Klage in Bezug auf Nichteinhaltung dieser Garantie muss innerhalb eines (1) Jahres ab dem Datum, an dem der An-
spruch entstanden ist, vorgebracht werden. Urbanista AB haftet nicht fr besondere, indirekte, zufl-
lige oder Folgeschden, die auf die Nutzung oder die Un-
mglichkeit der Nutzung dieses Produkts zurckgefhrt werden, unabhngig von dem Rechtsgrund, auf dem dieser Anspruch basiert. Diese Garantie gewhrt Ihnen besondere gesetzliche Rechte, und Sie haben mglicherweise weitere Rechte, die von Land zu Land unterschiedlich sein knnen. Diese Garantie ist keine Einschrnkung Ihrer Rechte nach der geltenden nationalen Gesetzgebung bezglich des Ver-
kaufs von Verbrauchsgtern. Dieses Produkt darf nicht als Haushaltsmll entsorgt werden, sondern es muss zu einer Sammelstelle fr Elektro- und Elektronikaltgerte gebracht werden. Dieses Produkt wurde nach dem 1. April 2019 gefertigt. 18 WARNUNGEN Nicht geeignet fr Kinder unter drei Jahren; enthlt Kleinteile, die verschluckt werden knnen und eine Er-
stickungsgefahr darstellen. Stellen Sie die Lautsprecher vor der Benutzung auf eine leise Lautstrke ein. Langanhaltende Lrmeinwirkung durch Anhren von lauter Musik oder lauten Geruschen kann zu Ge-
hrschden fhren. Vermeiden Sie hohe Lautstrkepe-
gel, insbesondere ber lngere Zeitrume, wenn Sie diese Kopfhrer benutzen. VORSICHT Durch Verwendung dieser Lautsprecher knnen Sie, unabhngig von der eingestellten Laustrke, Umge-
bungsgerusche nicht mehr zuverlssig wahrnehmen. Bitte seien Sie vorsichtig, wenn Sie diese Lautsprecher verwenden. Lassen Sie die Lautsprecher nicht fallen, setzen Sie sich nicht darauf und tauchen Sie sie nicht in Wasser ein. Bei etwaigen Fragen oder Vorbehalten wenden Sie sich bitte an:
support@urbanista.com 19
( J P N )
( J P N ) B Bluetooth Urbanista Sydney LED10 B B
/ - B3
/ - B
- B
- B
- B 1
- B 1
/ - B
- B1 SIRI - B 20 2 L E D B 1 LED2 10 Bluetooth Urbanista Sydney LED 10 2 B 2 B 21
( J P N )
( J P N ) Urbanista 1 Urbanista AB 201941 3 support@urbanista.com 1 Urbanista AB 1 Urbanista AB Urbanista AB 22 23 SYDNEY ( )
( K O R ) S Y D N E Y ( )
( K O R ) B
. Urbanista Syd-
ney . LED 10
.
. B . B
.
/- B 3 .
/- B .
- B .
- B .
- B 1 .
- B 1 .
/- B .
- B 1 . SIRI- B
. LED B 1
.
. LED 10
. Urbanista Sydney
. LED 10
.
. B .
. B
.
. 24 25
( K O R )
( K O R ) Urbanista AB
, ,
.
.
.
,
. 2019 4 1
. 3 .
.
.
. ,
.
.
.
.
. support@urbanista.com Urbanista
.
.
.
(1) . Urbanista AB
(1)
.
.
:
.
. Urbanista AB
.
, Urbanista AB , ,
,
. 1 . 26 27 www.urbani sta.com 28
1 2 | Appendix B-Test Data for BLE V4.0 | Test Report | 910.53 KiB | July 08 2019 |
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB Appendix B RF Test Data for BT V5.0(BLE) (Conducted Measurement) Product Name: Urbanista Sydney Trade Mark: Urbanista Test Model: Urbanista Sydney Environmental Conditions 23.9 C 52.9%
100.0 kPa JERRY ZENG Wang.Chuang Temperature:
Relative Humidity:
ATM Pressure:
Test Engineer:
Supervised by:
B.1 Duty Cycle Test Mode Test Channel BT LE 2440 Ant Ant1
#im grbble1hchnnav Duty Cycle[%]
100 Verdict PASS Page 1 of 14 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB B.2 Maximum Conducted Peak Output Power Mode BT LE BT LE BT LE Channel Conduct Peak Power[dBm]
Limit [dBm]
Verdict LCH MCH HCH
-5.733
-5.406
-6.288 Test Graphs 30 30 30 PASS PASS PASS LCH MCH Page 2 of 14 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB HCH Page 3 of 14 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB B.3 Maximum Power Spectral Density Mode BT LE BT LE BT LE Channel PSD [dBm/3KHz]
Limit [dBm/3KHz]
Verdict LCH MCH HCH
-22.220
-21.822
-22.908 Test Graphs 8 8 8 PASS PASS PASS LCH MCH Page 4 of 14 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB HCH Page 5 of 14 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB B.4 6dB Bandwidth Mode BT LE BT LE BT LE Channel 6dB Bandwidth [MHz]
Limit [MHz]
Verdict LCH MCH HCH 0.6483 0.6464 0.6571 Test Graphs 0.5 0.5 0.5 PASS PASS PASS LCH MCH Page 6 of 14 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB HCH Page 7 of 14 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB B.5 RF Conducted Spurious Emissions Mode BT LE BT LE BT LE Channel Pref [dBm]
Max. Level [dBm]
Limit [dBm]
Verdict LCH MCH HCH
-6.313
-6.175
-7.216
-43.636
-44.554
-44.088
-26.313
-26.175
-27.216 PASS PASS PASS BT LE_LCH_Graphs Pref/BT LE/LCH Puw/BT LE/LCH Page 8 of 14 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB BT LE_MCH_Graphs Pref/BT LE/MCH Puw/BT LE/MCH Page 9 of 14 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB BT LE_HCH_Graphs Pref/BT LE/HCH Puw/BT LE/HCH Page 10 of 14 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB B.6 Band-edge for RF Conducted Emissions Mode Channel Carrier Power[dBm]
BT LE BT LE LCH HCH
-6.330
-6.978 Max.Spurious Level
[dBm]
-50.267
-49.371 Limit [dBm]
Verdict
-26.33
-26.98 PASS PASS Test Graphs LCH HCH Page 11 of 14 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB B.7 Restrict-band band-edge measurements Test Chann Ant Freq. Power
[dBm]
Gain Ground E Factor
[dBuV/m]
Limit Detector
[dBuV/
m]
Verdi ct Test Mode BT LE el 2402 Ant1 2310.0
-42.05 Ant1 2310.0
-53.36 Ant1 2390.0
-41.65 Ant1 2390.0
-53.14 Ant1 2483.5
-43.38 2480 Ant1 2483.5
-52.96 Ant1 2500.0
-42.54 Ant1 2500.0
-52.85 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 0 0 0 0 0 0 0 0 53.21 PEAK 74 PASS 41.90 AV 54 PASS 53.60 PEAK 74 PASS 42.12 AV 54 PASS 51.88 PEAK 74 PASS 42.29 AV 54 PASS 52.72 PEAK 74 PASS 42.41 AV 54 PASS Page 12 of 14 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB Restrict-band band-edge measurements_BT LE_2402_Ant1_PEAK Restrict-band band-edge measurements_BT LE_2402_Ant1_AV Page 13 of 14 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB Restrict-band band-edge measurements_BT LE_2480_Ant1_PEAK Restrict-band band-edge measurements_BT LE_2480_Ant1_AV Page 14 of 14
1 2 | Confidentiality Request Letter | Cover Letter(s) | 69.35 KiB | July 08 2019 |
Urbanista Address: Master Samuelsgatan 10 ,SE-111 44, Stockholm, 11144, Sweden Tel: 0046 723200090 Fax: 0046 8303820 2019-08-02 To:
Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Confidentiality Request regarding application for certification of FCC ID: 2AJD8UN-SYDNEY We hereby request confidential treatment of information accompanying this application as outlined below:
- Schematics Diagram
- Block Diagram
- Operation description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Name/Title: Martin Wennberg / Product Manager Company: Urbanista AB Address: Master Samuelsgatan 10 ,SE-111 44, Stockholm, 11144, Sweden Tel: 0046 723200090 Fax: 0046 8303820 E-Mail: martin@urbanista.com
1 2 | External Photos | External Photos | 1.09 MiB | July 08 2019 |
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY 1. EXTERIOR PHOTOGRAPHS Fig. 1 Fig. 2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Fig. 3 Fig. 4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Fig. 5 Fig. 6 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Fig. 7 Fig. 8 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Fig. 9 Fig. 10 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Fig. 11 Fig. 12 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Fig. 13
1 2 | Internal Photos | Internal Photos | 440.00 KiB | July 08 2019 |
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY 1. INTERIOR PHOTOGRAPHS Fig.1 Fig.2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Antenna Fig.3 Fig.4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Fig.5
1 2 | LCS190702116AEB report-DTS | Test Report | 749.32 KiB | July 08 2019 |
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB FCC TEST REPORT For Urbanista AB Urbanista Sydney Test Model: Urbanista Sydney Additional Model No.: Please Refer To Page 06
: Urbanista AB
: Master Samuelsgatan 10 ,SE-111 44, Stockholm, 11144, Sweden
: Shenzhen LCS Compliance Testing Laboratory Ltd. 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China
(+86)755-82591330
(+86)755-82591332
:
:
:
Prepared for Address Prepared by Address Tel Fax Web Mail Date of receipt of test sample Number of tested samples Serial number Date of Test Date of Report
: www.LCS-cert.com
: webmaster@LCS-cert.com
:
:
July 17, 2019 1
: Prototype
:
:
July 17, 2019 ~ July 24, 2019 July 25, 2019 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB FCC TEST REPORT FCC CFR 47 PART 15 C (15.247) Report Reference No. ................. : LCS190702116AEB Date of Issue ................................... : July 25, 2019 Testing Laboratory Name ............. : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ........................................... :
Testing Location/ Procedure ...........
:
1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China Full application of Harmonised standards Partial application of Harmonised standards Other standard testing method Applicants Name .......................... : Urbanista AB Address ........................................... : Master Samuelsgatan 10 ,SE-111 44, Stockholm, 11144, Sweden Test Specification Standard .......................................... : FCC CFR 47 PART 15 C (15.247) Test Report Form No. ................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. EUT Description. ........................... : Urbanista Sydney Trade Mark ...................................... : Urbanista Model/ Type reference .................... : Urbanista Sydney Ratings ............................................ : DC 3.7V by battery(600mA) Result ............................................ : Positive Compiled by:
Supervised by:
Jerry Zeng / File administrators Camille Li / Technique principal Approved by:
Gavin Liang/ Manager This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB FCC -- TEST REPORT Test Report No. :
LCS190702116AEB July 25, 2019 Date of issue Type / Model...........................
: Urbanista Sydney EUT......................................... : Urbanista Sydney Applicant...............................
: Urbanista AB Address..................................
: Master Samuelsgatan 10 ,SE-111 44, Stockholm, 11144, Sweden Telephone............................... Fax..........................................
: /
: /
Manufacturer........................
: Iglory Limited Address................................... :
4 floor, No 2223, C buiding, Xuegang road, Bantian street, Longgang, Shenzhen, China Telephone............................... : /
Fax..........................................
: /
Factory...................................
: Iglory Limited Address................................... :
4 floor, No 2223, C buiding, Xuegang road, Bantian street, Longgang, Shenzhen, China Telephone............................... : /
Fax..........................................
: /
Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB Revision History Revision 000 Issue Date July 25, 2019 Revisions Initial Issue Revised By Gavin Liang This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 4 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB TABLE OF CONTENTS 1. GENERAL INFORMATION .................................................................................................................................... 6 1.1. DESCRIPTION OF DEVICE (EUT) ........................................................................................................................ 6 1.2 SUPPORT EQUIPMENT LIST .................................................................................................................................. 6 1.3 EXTERNAL I/O CABLE .......................................................................................................................................... 6 1.4. DESCRIPTION OF TEST FACILITY ........................................................................................................................ 7 1.5. STATEMENT OF THE MEASUREMENT UNCERTAINTY .......................................................................................... 7 1.6. MEASUREMENT UNCERTAINTY ........................................................................................................................... 7 1.7. DESCRIPTION OF TEST MODES .......................................................................................................................... 8 2. TEST METHODOLOGY ......................................................................................................................................... 9 2.1. EUT CONFIGURATION ........................................................................................................................................ 9 2.2. EUT EXERCISE ................................................................................................................................................... 9 2.3. GENERAL TEST PROCEDURES ........................................................................................................................... 9 3. SYSTEM TEST CONFIGURATION .................................................................................................................... 10 3.1. JUSTIFICATION .................................................................................................................................................. 10 3.2. EUT EXERCISE SOFTWARE .............................................................................................................................. 10 3.3. SPECIAL ACCESSORIES .................................................................................................................................... 10 3.4. BLOCK DIAGRAM/SCHEMATICS......................................................................................................................... 10 3.5. EQUIPMENT MODIFICATIONS ............................................................................................................................ 10 3.6. TEST SETUP ...................................................................................................................................................... 10 4. SUMMARY OF TEST RESULTS ........................................................................................................................ 11 5. TEST RESULT ....................................................................................................................................................... 12 5.1. ON TIME AND DUTY CYCLE .............................................................................................................................. 12 5.2. MAXIMUM CONDUCTED OUTPUT POWER MEASUREMENT ............................................................................... 13 5.3. POWER SPECTRAL DENSITY MEASUREMENT .................................................................................................. 14 5.4. 6 DB SPECTRUM BANDWIDTH MEASUREMENT ................................................................................................ 15 5.5. RADIATED EMISSIONS MEASUREMENT ............................................................................................................. 16 5.6. CONDUCTED SPURIOUS EMISSIONS AND BAND EDGES TEST ......................................................................... 25 5.7. AC POWER LINE CONDUCTED EMISSIONS (NOT APPLICABLE) ....................................................................... 26 5.8. BAND-EDGE MEASUREMENTS FOR RADIATED EMISSIONS .............................................................................. 28 5.9. ANTENNA REQUIREMENTS ................................................................................................................................ 30 6. SUMMARY OF TEST EQUIPMENT ................................................................................................................... 30 7. TEST SETUP PHOTOGRAPHS OF EUT .......................................................................................................... 31 8. EXTERIOR PHOTOGRAPHS OF THE EUT ..................................................................................................... 31 9. INTERIOR PHOTOGRAPHS OF THE EUT ...................................................................................................... 31 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 5 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB 1. GENERAL INFORMATION 1.1. Description of Device (EUT) EUT
: Urbanista Sydney Test Model
: Urbanista Sydney Additional Model No. Model Declaration
:
:
Urbanista Sydney Midnight Black, Urbanista Sydney White Mist, Urbanista Sydney Rose Gold, Urbanista Sydney Olive Green PCB board, structure and internal of these model(s) are the same, So no additional models were tested. Power Supply
: DC 3.7V by battery(600mA) Hardware version Software version
: V1.0
: V1.0 Bluetooth Operation frequency : 2402MHz-2480MHz Bluetooth Version
: V5.0 Bluetooth Channel Number
:
79 Channels for Bluetooth V5.0 (BDR/EDR) 40 channels for Bluetooth V5.0 (BT LE) Bluetooth Channel Spacing
:
1MHz for Bluetooth V5.0 (BDR/EDR) 2MHz for Bluetooth V5.0 (BT LE) Bluetooth Modulation Type
:
GFSK, /4-DQPSK, 8DPSK for Bluetooth V5.0 (BDR/EDR) GFSK for Bluetooth V5.0 (BT LE) Antenna Description
: PCB Antenna, -0.58dBi 1.2 Support equipment List Manufacturer Description Lenovo Lenovo Notebook AC/DC ADAPTER Model B470 Serial Number Certificate WB05067151 DOC ADP-90DD B 36001941 DOC 1.3 External I/O Cable I/O Port Description Quantity USB Port AUX 1 1 Cable N/A N/A This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 6 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB 1.4. Description of Test Facility FCC Registration Number is 254912. Industry Canada Registration Number is 9642A-1. EMSD Registration Number is ARCB0108. UL Registration Number is 100571-492. TUV SUD Registration Number is SCN1081. TUV RH Registration Number is UA 50296516-001. NVLAP Accreditation Code is 600167-0. FCC Designation Number is CN5024. CAB identifier: CN0071 The 3m-Semi anechoic test site fulfils CISPR 16-1-4 according to ANSI C63.10:2013 and CISPR 16-1-4:2010 SVSWR requirement for radiated emission above 1GHz. 1.5. Statement of the Measurement Uncertainty The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated for all measurements listed in this test report acc. To CISPR 16 4 Specification for radio disturbance and immunity measuring apparatus and methods Part 4: Uncertainty in EMC Measurements and is documented in the LCS quality system acc. To DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device. 1.6. Measurement Uncertainty Test Item Frequency Range Uncertainty Note Radiation Uncertainty
:
200MHz~1000MHz 9KHz~30MHz 30MHz~200MHz Conduction Uncertainty Power disturbance
:
:
1GHz~26.5GHz 26.5GHz~40GHz 150kHz~30MHz 30MHz~300MHz 3.10dB 2.96dB 3.10dB 3.80dB 3.90dB 1.63dB 1.60dB
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1). This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 7 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB 1.7. Description of Test Modes The EUT has been tested under operating condition. This test was performed with EUT in X, Y, Z position and the worst case was found when EUT in X position. Worst-case mode and channel used for 9 KHz-1000 MHz radiated emissions was the mode and channel with the highest output power, that was determined to be BT LE mode(Low Channel). Worst-Case data rates were utilized from preliminary testing of the Chipset, worst-case data rates used during the testing are as follows:
BT LE: 1 Mbps, GFSK. BLE 5.0 Frequency Band Channel No. Frequency (MHz) Channel No. Frequency (MHz) 2402~2480MHz 0 1 2
--
--
19 2402 2404 2406
--
--
2440 20
--
--
37 38 39 2442
--
--
2476 2478 2480 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 8 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB 2. TEST METHODOLOGY All measurements contained in this report were conducted with ANSI C63.10-2013, American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices. The radiated testing was performed at an antenna-to-EUT distance of 3 meters. All radiated and conducted emissions measurement was performed at Shenzhen LCS Compliance Testing Laboratory Ltd. 2.1. EUT Configuration The EUT configuration for testing is installed on RF field strength measurement to meet the Commissions requirement and operating in a manner that intends to maximize its emission characteristics in a continuous normal application. 2.2. EUT Exercise The EUT was operated in the engineering mode to fix the TX frequency that was for the purpose of the measurements. According to FCCs request, Test Procedure KDB558074 D01 DTS Meas. Guidance is required to be used for this kind of FCC 15.247 digital modulation device. According to its specifications, the EUT must comply with the requirements of the Section 15.203, 15.205, 15.207, 15.209 and 15.247 under the FCC Rules Part 15 Subpart C. 2.3. General Test Procedures 2.3.1 Conducted Emissions The EUT is placed on the turntable, which is 0.8 m above ground plane. According to the requirements in Section 6.2.1 of ANSI C63.10-2013 Conducted emissions from the EUT measured in the frequency range between 0.15 MHz and 30MHz using Quasi-peak and average detector modes. 2.3.2 Radiated Emissions The EUT is placed on a turn table, which is 0.8 m above ground plane. The turntable shall rotate 360 degrees to determine the position of maximum emission level. EUT is set 3m away from the receiving antenna, which varied from 1m to 4m to find out the highest emission. And also, each emission was to be maximized by changing the polarization of receiving antenna both horizontal and vertical. In order to find out the maximum emissions, exploratory radiated emission measurements were made according to the requirements in Section 6.3 of ANSI C63.10-2013. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 9 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB 3. SYSTEM TEST CONFIGURATION 3.1. Justification The system was configured for testing in a continuous transmit condition. The duty cycle is 100% and the average correction factor is 0. 3.2. EUT Exercise Software The system was configured for testing in a continuous transmits condition and change test channels by software (FCCAssist 2.4_v1.0) provided by applicant. 3.3. Special Accessories Manufacturer Description Lenovo Lenovo Notebook AC/DC ADAPTER 3.4. Block Diagram/Schematics Please refer to the related document 3.5. Equipment Modifications Model B470 Serial Number Certificate WB05067151 CE CE ADP-90DD B 36001941 Shenzhen LCS Compliance Testing Laboratory Ltd. has not done any modification on the EUT. 3.6. Test Setup Please refer to the test setup photo. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 10 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB 4. SUMMARY OF TEST RESULTS Applied Standard: FCC Part 15 Subpart C FCC Rules Description of Test Result Remark
/
On Time and Duty Cycle
/
Appendix B.1 15.247(b) Maximum Conducted Output Power Compliant Appendix B.2 15.247(e) 15.247(a)(2) Power Spectral Density Compliant Appendix B.3 6dB Bandwidth Compliant Appendix B.4 2.1049 99% Occupied Bandwidth
/
/
15.209, 15.247(d) Conducted Spurious Emissions Compliant Appendix B.5 Appendix B.6 15.209, 15.247(d) Radiated Spurious Emissions Compliant Note 1 15.205 Emissions at Restricted Band Compliant Appendix B.7 15.207(a) AC Mains Conducted Emissions 15.203 Antenna Requirements 15.247(i)2.1093 RF Exposure Compliant Compliant Compliant Note 1 Note 1 Note 3 Remark:
1. Note 1 Test results inside test report;
2. Note 2 Not Applicable!!!
3. Note 3 Test results in other test report (RF Exposure Evaluation Report);
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 11 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB 5. TEST RESULT 5.1. On Time and Duty Cycle 5.1.1. Standard Applicable None; for reporting purpose only. 5.1.2. Measuring Instruments and Setting Please refer to equipment list in this report. The following table is the setting of the spectrum analyzer. 5.1.3. Test Procedures 1. Set the center frequency of the spectrum analyzer to the transmitting frequency;
2. Set the span=0MHz, RBW=8MHz, VBW=50MHz, Sweep time=5ms;
3. Detector = peak;
4. Trace mode = Single hold. 5.1.4. Test Setup Layout 5.1.5. EUT Operation during Test The EUT was programmed to be in continuously transmitting mode. 5.1.6. Test result For reporting purpose only. Please refer to Appendix B.1 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 12 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB 5.2. Maximum Conducted Output Power Measurement 5.2.1. Standard Applicable For systems using digital modulation in the 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz bands:
1 Watt. As an alternative to a peak power measurement, compliance with the one Watt limit can be based on a measurement of the maximum conducted output power. Maximum Conducted Output Power is defined as the total transmit power delivered to all antennas and antenna elements averaged across all symbols in the signaling alphabet when the transmitter is operating at its maximum power control level. Power must be summed across all antennas and antenna elements. The average must not include any time intervals during which the transmitter is off or is transmitting at a reduced power level. If multiple modes of operation are possible (e.g., alternative modulation methods), the maximum conducted output power is the highest total transmit power occurring in any mode. 5.2.2. Test Procedures The transmitter output (antenna port) was connected to the spectrum analyzer. According to KDB558074 D01 DTS Measurement Guidance Section 9.1 Maximum peak conducted output power 9.1.1. This procedure shall be used when the measurement instrument has available a resolution bandwidth that is greater than the DTS bandwidth. a) Set the RBW DTS bandwidth. b) Set VBW 3 RBW. c) Set span 3 x RBW d) Sweep time = auto couple. e) Detector = peak. f) Trace mode = max hold. g) Allow trace to fully stabilize. h) Use peak marker function to determine the peak amplitude level. 5.2.3. Test Setup Layout 5.2.4. EUT Operation during Test The EUT was programmed to be in continuously transmitting mode. 5.2.5. Test Result of Maximum Conducted Output Power PASS Please refer to Appendix B.2 Remark:
1. Test results including cable loss;
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 13 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB 5.3. Power Spectral Density Measurement 5.3.1. Standard Applicable According to 15.247(e): For digitally modulated systems, the power spectral density conducted from the intentional radiator to the antenna shall not be greater than 8 dBm in any 3 kHz band during any time interval of continuous transmission. 5.3.2. Measuring Instruments and Setting Please refer to equipment list in this report. The following table is the setting of Spectrum Analyzer. 5.3.3. Test Procedures 1. Use this procedure when the maximum peak conducted output power in the fundamental emission is used to demonstrate compliance. 2. The power was monitored at the coupler port with a Spectrum Analyzer. The power level was set to the maximum level. 3. Set the RBW = 3 kHz. 4. Set the VBW 3*RBW 5. Set the span to 1.5 times the DTS channel bandwidth. 6. Detector = peak. 7. Sweep time = auto couple. 8. Trace mode = max hold. 9. Allow trace to fully stabilize. 10. Use the peak marker function to determine the maximum power level. 11. If measured value exceeds limit, reduce RBW (no less than 3 kHz) and repeat. 12. The resulting peak PSD level must be 8 dBm. 5.3.4. Test Setup Layout 5.3.5. EUT Operation during Test The EUT was programmed to be in continuously transmitting mode. 5.3.6. Test Result of Power Spectral Density PASS Please refer to Appendix B.3 Remark:
1. Test results including cable loss;
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 14 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB 5.4. 6 dB Spectrum Bandwidth Measurement 5.4.1. Standard Applicable According to 15.247(a) (2): For digital modulation systems, the minimum 6 dB bandwidth shall be at least 500 kHz. 5.4.2. Measuring Instruments and Setting Please refer to equipment list in this report. The following table is the setting of the Spectrum Analyzer. Spectrum Parameter Attenuation RBW VBW Span Frequency Detector Trace Sweep Time 5.4.3. Test Procedures Setting Auto 100KHz 3*RBW
> RBW Peak Max Hold 1ms 1. The transmitter output (antenna port) was connected to the spectrum analyzer in peak hold mode. 2. The resolution bandwidth and the video bandwidth were set according to KDB558074. 3. Measured the spectrum width with power higher than 6dB below carrier. 5.4.4. Test Setup Layout 5.4.5. EUT Operation during Test The EUT was programmed to be in continuously transmitting mode. 5.4.6. Test Result of 6dB Spectrum Bandwidth PASS Please refer to Appendix B.4 Remark:
1. Test results including cable loss;
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 15 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB 5.5. Radiated Emissions Measurement 5.5.1. Standard Applicable 15.205 (a) Except as shown in paragraph (d) of this section, only spurious emissions are permitted in any of the frequency bands listed below:
MHz MHz MHz GHz 0.090-0.110
\1\ 0.495-0.505 2.1735-2.1905 4.125-4.128 4.17725-4.17775 4.20725-4.20775 6.215-6.218 6.26775-6.26825 6.31175-6.31225 8.291-8.294 8.362-8.366 8.37625-8.38675 8.41425-8.41475 12.29-12.293. 12.51975-12.52025 12.57675-12.57725 13.36-13.41 16.42-16.423 16.69475-16.69525 16.80425-16.80475 25.5-25.67 37.5-38.25 73-74.6 74.8-75.2 108-121.94 123-138 149.9-150.05 156.52475-156.52525 156.7-156.9 162.0125-167.17 167.72-173.2 240-285 322-335.4 399.9-410 608-614 960-1240 1300-1427 1435-1626.5 1645.5-1646.5 1660-1710 1718.8-1722.2 2200-2300 2310-2390 2483.5-2500 2690-2900 3260-3267 3332-3339 3345.8-3358 3600-4400 4.5-5.15 5.35-5.46 7.25-7.75 8.025-8.5 9.0-9.2 9.3-9.5 10.6-12.7 13.25-13.4 14.47-14.5 15.35-16.2 17.7-21.4 22.01-23.12 23.6-24.0 31.2-31.8 36.43-36.5
(\2\)
\1\ Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz.
\2\ Above 38.6 According to 15.247 (d): 20dBc in any 100 kHz bandwidth outside the operating frequency band. In case the emission fall within the restricted band specified on 15.205(a), then the 15.209(a) limit in the table below has to be followed. Frequencies
(MHz) 0.009~0.490 0.490~1.705 1.705~30.0 30~88 88~216 216~960 Above 960 Field Strength
(microvolts/meter) 2400/F(KHz) 24000/F(KHz) 30 100 150 200 500 Measurement Distance
(meters) 300 30 30 3 3 3 3 5.5.2. Measuring Instruments and Setting Please refer to equipment list in this report. The following table is the setting of spectrum analyzer and receiver. Spectrum Parameter Setting Attenuation Auto Start Frequency 1000 MHz 10th carrier harmonic Stop Frequency RB / VB (Emission in restricted band) 1MHz / 1MHz for Peak, 1 MHz / 1/B kHz for Average RB / VB (Emission in non-restricted band) 1MHz / 1MHz for Peak, 1 MHz / 1/B kHz for Average Receiver Parameter Attenuation Start ~ Stop Frequency Start ~ Stop Frequency Start ~ Stop Frequency Setting Auto 9kHz~150kHz / RB/VB 200Hz/1KHz for QP/AVG 150kHz~30MHz / RB/VB 9kHz/30KHz for QP/AVG 30MHz~1000MHz / RB/VB 120kHz/1MHz for QP This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 16 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB 5.5.3. Test Procedures 1) Sequence of testing 9 kHz to 30 MHz Setup:
--- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer.
--- If the EUT is a tabletop system, a rotatable table with 0.8 m height is used.
--- If the EUT is a floor standing device, it is placed on the ground.
--- Auxiliary equipment and cables were positioned to simulate normal operation conditions.
--- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
--- The measurement distance is 3 meter.
--- The EUT was set into operation. Premeasurement:
--- The turntable rotates from 0 to 315 using 45 steps.
--- The antenna height is 0.8 meter.
--- At each turntable position the analyzer sweeps with peak detection to find the maximum of all emissions Final measurement:
--- Identified emissions during the premeasurement the software maximizes by rotating the turntable position (0 to 360) and by rotating the elevation axes (0 to 360).
--- The final measurement will be done in the position (turntable and elevation) causing the highest emissions with QPK detector.
--- The final levels, frequency, measuring time, bandwidth, turntable position, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement and the limit will be stored. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 17 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB 2) Sequence of testing 30 MHz to 1 GHz Setup:
--- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer.
--- If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed on the ground plane.
--- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
--- Auxiliary equipment and cables were positioned to simulate normal operation conditions
--- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
--- The measurement distance is 3 meter.
--- The EUT was set into operation. Premeasurement:
--- The turntable rotates from 0 to 315 using 45 steps.
--- The antenna is polarized vertical and horizontal.
--- The antenna height changes from 1 to 4 meter.
--- At each turntable position, antenna polarization and height the analyzer sweeps three times in peak to find the maximum of all emissions. Final measurement:
--- The final measurement will be performed with minimum the six highest peaks.
--- According to the maximum antenna and turntable positions of premeasurement the software maximize the peaks by changing turntable position ( 45) and antenna movement between 1 and 4 meter.
--- The final measurement will be done with QP detector with an EMI receiver.
--- The final levels, frequency, measuring time, bandwidth, antenna height, antenna polarization, turntable angle, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement with marked maximum final measurements and the limit will be stored. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 18 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB 3) Sequence of testing 1 GHz to 18 GHz Setup:
--- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer.
--- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
--- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
--- Auxiliary equipment and cables were positioned to simulate normal operation conditions
--- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
--- The measurement distance is 3 meter.
--- The EUT was set into operation. Premeasurement:
--- The turntable rotates from 0 to 315 using 45 steps.
--- The antenna is polarized vertical and horizontal.
--- The antenna height scan range is 1 meter to 4 meter.
--- At each turntable position and antenna polarization the analyzer sweeps with peak detection to find the maximum of all emissions. Final measurement:
--- The final measurement will be performed with minimum the six highest peaks.
--- According to the maximum antenna and turntable positions of premeasurement the software maximize the peaks by changing turntable position ( 45) and antenna movement between 1 and 4 meter. This procedure is repeated for both antenna polarizations.
--- The final measurement will be done in the position (turntable, EUT-table and antenna polarization) causing the highest emissions with Peak and Average detector.
--- The final levels, frequency, measuring time, bandwidth, turntable position, EUT-table position, antenna polarization, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement with marked maximum final measurements and the limit will be stored. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 19 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB 4) Sequence of testing above 18 GHz Setup:
--- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer.
--- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
--- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
--- Auxiliary equipment and cables were positioned to simulate normal operation conditions
--- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
--- The measurement distance is 1 meter.
--- The EUT was set into operation. Premeasurement:
--- The antenna is moved spherical over the EUT in different polarizations of the antenna. Final measurement:
--- The final measurement will be performed at the position and antenna orientation for all detected emissions that were found during the premeasurements with Peak and Average detector.
--- The final levels, frequency, measuring time, bandwidth, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement and the limit will be stored. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 20 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB 5.5.4. Test Setup Layout Above 18 GHz shall be extrapolated to the specified distance using an extrapolation factor of 20 dB/decade form 3m to 1m. Distance extrapolation factor = 20 log (specific distanc [3m] / test distance [1m]) (dB);
Limit line = specific limits (dBuV) + distance extrapolation factor [6 dB]. 5.5.5. EUT Operation during Test The EUT was programmed to be in continuously transmitting mode. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 21 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB 5.5.6. Results of Radiated Emissions (9 KHz~30MHz) Temperature Test Engineer 25.2 JK Zhou Humidity Configurations 53.7%
BT LE Freq.
(MHz)
-
Note:
Level
(dBuV)
-
Over Limit
(dB)
-
Over Limit
(dBuV)
-
Remark See Note The amplitude of spurious emissions which are attenuated by more than 20 dB below the permissible value has no need to be reported. Distance extrapolation factor = 40 log (specific distance / test distance) (dB);
Limit line = specific limits (dBuV) + distance extrapolation factor. 5.5.7. Results of Radiated Emissions (30MHz~1GHz) Temperature Test Engineer Test result for BT LE (Low Channel) Horizontal 25.2 JK Zhou Humidity 53.7%
Configurations BT LE (Low CH) This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 22 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB Vertical Note:
1). Pre-scan all modes and recorded the worst case results in this report (BT LE (Low Channel)). 2). Emission level (dBuV/m) = 20 log Emission level (uV/m). 3). Corrected Reading: Antenna Factor + Cable Loss + Read Level - Preamp Factor = Level. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 23 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB 5.5.8. Results for Radiated Emissions (Above 1GHz) BT LE Channel 0 / 2402 MHz Freq. MHz Reading dBuV Ant. Fac. dB/m Pre. Fac. dB Cab. Loss dB Measured dBuV/m Limit Margin dBuV/m dB Remark Pol. 4804.00 52.08 33.06 35.04 3.94 54.04 74.00 4804.00 40.24 33.06 35.04 3.94 42.20 54.00 4804.00 52.04 33.06 35.04 3.94 54.00 74.00 4804.00 39.89 33.06 35.04 3.94 41.85 54.00 Horizontal
-19.96 Peak
-11.80 Average Horizontal Vertical
-20.00 Peak
-12.15 Average Vertical Channel 19 / 2440 MHz Freq. MHz Reading dBuV Ant. Fac. dB/m Pre. Fac. dB Cab. Loss dB Measured dBuV/m Limit Margin dBuV/m dB Remark Pol. 4880.00 51.01 33.16 35.15 3.96 52.98 74.00 4880.00 40.07 33.16 35.15 3.96 42.04 54.00 4880.00 50.17 33.16 35.15 3.96 52.14 74.00 4880.00 36.59 33.16 35.15 3.96 38.56 54.00 Peak Horizontal
-21.02
-11.96 Average Horizontal Vertical Peak
-21.86
-15.44 Average Vertical Channel 39 / 2480 MHz Freq. MHz Reading dBuV Ant. Fac. dB/m Pre. Fac. dB Cab. Loss dB Measured dBuV/m Limit Margin dBuV/m dB Remark Pol. 4960.00 51.41 33.26 35.14 3.98 53.51 74.00 4960.00 41.11 33.26 35.14 3.98 43.21 54.00 4960.00 52.16 33.26 35.14 3.98 54.26 74.00 4960.00 37.76 33.26 35.14 3.98 39.86 54.00 Notes:
Peak Horizontal
-20.49
-10.79 Average Horizontal Vertical Peak
-19.74
-14.14 Average Vertical 1). Measuring frequencies from 9 KHz~10th harmonic or 26.5GHz (which is less), No emission found between lowest internal used/generated frequency to 30MHz. 2). Radiated emissions measured in frequency range from 9 KHz~10th harmonic or 26.5GHz (which is less) were made with an instrument using Peak detector mode. 3). Data of measurement within this frequency range shown --- in the table above means the reading of emissions are attenuated more than 20dB below the permissible limits or the field strength is too small to be measured. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 24 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB 5.6. Conducted Spurious Emissions and Band Edges Test 5.6.1. Standard Applicable According to 15.247 (d): In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement. Attenuation below the general limits specified in Section 15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in Section 15.205(a), must also comply with the radiated emission limits specified in Section 15.209(a) (see Section 15.205(c)). 5.6.2. Measuring Instruments and Setting Please refer to equipment list in this report. The following table is the setting of the spectrum analyzer. Spectrum Parameter Detector Attenuation RB / VB (Emission in restricted band) RB / VB (Emission in non-restricted band) Setting Peak Auto 100KHz/300KHz 100KHz/300KHz 5.6.3. Test Procedures The transmitter output is connected to a spectrum analyzer. The resolution bandwidth is set to 100 kHz. The video bandwidth is set to 300 kHz The spectrum from 9 kHz to 26.5GHz is investigated with the transmitter set to the lowest, middle, and highest channels. 5.6.4. Test Setup Layout This test setup layout is the same as that shown in section 5.4.4. 5.6.5. EUT Operation during Test The EUT was programmed to be in continuously transmitting mode. 5.6.6. Test Results of Conducted Spurious Emissions PASS Please refer to Appendix B.5 for conducted spurious emissions;
Please refer to Appendix B.6 for conducted band edge emission. Remark:
1). Test results including cable loss;
2). ---means that the fundamental frequency not for 15.209 limits requirement. 3). Not recorded emission from 9 KHz to 30 MHz as emission level at least 20dBc lower than emission limit. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 25 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB 5.7. AC Power Line Conducted Emissions 5.7.1 Standard Applicable According to 15.207 (a): For an intentional radiator which is designed to be connected to the public utility
(AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed 250 microvolts (The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz). The limits at specific frequency range is listed as follows:
Frequency Range
(MHz) 0.15 to 0.50 0.50 to 5 5 to 30 Limits (dBV) Quasi-peak 66 to 56 56 60 Average 56 to 46 46 50
* Decreasing linearly with the logarithm of the frequency 5.7.2 Block Diagram of Test Setup 5.7.3 Test Results PASS. The test data please refer to following page. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 26 of 33 EUT LISN EMI receiver Reference ground plane Vert. reference plane SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB AC Conducted Emission of GFSK middle channel @ AC 120V/60Hz (worst case) Line Neutral
***Note: Pre-scan all modes and recorded the worst case results in this report This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 27 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB 5.8. Band-edge Measurements for Radiated Emissions 5.8.1 Standard Applicable In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. If the transmitter complies with the conducted power limits based on the use of RMS averaging over a time interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 dB instead of 20 dB. Attenuation below the general limits specified in 15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in 15.205(a), must also comply with the radiated emission limits specified in 15.209(a) (see 15.205(c)). 5.8.2. Test Setup Layout 5.8.3. Measuring Instruments and Setting Please refer to equipment list in this report. The following table is the setting of Spectrum Analyzer. 5.8.4. Test Procedures According to KDB 558074 D01 for Antenna-port conducted measurement. Antenna-port conducted measurements may also be used as an alternative to radiated measurements for demonstrating compliance in the restricted frequency bands. If conducted measurements are performed, then proper impedance matching must be ensured and an additional radiated test for cabinet/case spurious emissions is required. 1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal from an external generator. 2. Remove the antenna from the EUT and then connect to a low loss RF cable from the antenna port to an EMI test receiver, then turn on the EUT and make it operate in transmitting mode. Then set it to Low Channel and High Channel within its operating range, and make sure the instrument is operated in its linear range. 3. Set both RBW and VBW of spectrum analyzer to 100 kHz with a convenient frequency span including 100kHz bandwidth from band edge, for Radiated emissions restricted band RBW=1MHz, VBW=3MHz for peak detector and RBW=1MHz, VBW=1/B for Peak detector. 4. Measure the highest amplitude appearing on spectral display and set it as a reference level. Plot the graph with marking the highest point and edge frequency. 5. Repeat above procedures until all measured frequencies were complete. 6. Measure the conducted output power (in dBm) using the detector specified by the appropriate regulatory agency (see 12.2.2, 12.2.3, and 12.2.4 for guidance regarding measurement procedures for determining quasi-peak, peak, and average conducted output power, respectively). 7. Add the maximum transmit antenna gain (in dBi) to the measured output power level to determine the EIRP level (see 12.2.5 for guidance on determining the applicable antenna gain) 8. Add the appropriate maximum ground reflection factor to the EIRP level (6 dB for frequencies 30 MHz, 4.7 dB for frequencies between 30 MHz and 1000 MHz, inclusive and 0 dB for frequencies > 1000 MHz). 9. For devices with multiple antenna-ports, measure the power of each individual chain and sum the EIRP of all chains in linear terms (e.g., Watts, mW). 10. Convert the resultant EIRP level to an equivalent electric field strength using the following relationship:
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 28 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB E = EIRP 20log D + 104.8 Where:
E = electric field strength in dBV/m, EIRP = equivalent isotropic radiated power in dBm D = specified measurement distance in meters. 11. Since the out-of-band characteristics of the EUT transmit antenna will often be unknown, the use of a conservative antenna gain value is necessary. Thus, when determining the EIRP based on the measured conducted power, the upper bound on antenna gain for a device with a single RF output shall be selected as the maximum in-band gain of the antenna across all operating bands, or 2 dBi, whichever is greater. However, for devices that operate in multiple frequency bands while using the same transmit antenna, the highest gain of the antenna within the operating band nearest in frequency to the restricted band emission being measured may be used in lieu of the overall highest gain when the emission is at a frequency that is within 20 percent of the nearest band edge frequency, but in no case shall a value less than 2 dBi be used. 12. Compare the resultant electric field strength level to the applicable regulatory limit. 13. Perform radiated spurious emission test duress until all measured frequencies were complete. 5.8.5 Test Results PASS Please refer to Appendix B.7 Remark:
1). Test results including cable loss;
2). ---means that the fundamental frequency not for 15.209 limits requirement;
3). The average measurement was not performed when the peak measured data under the limit of average detection. 4). Detector AV is setting spectrum/receiver. RBW=1MHz/VBW=330Hz/Sweep time=Auto/Detector=Peak. 5). Since the out-of-band characteristics of the EUT transmit antenna will often be unknown, the use of a conservative antenna gain value is necessary. Thus, when determining the EIRP based on the measured conducted power, the upper bound on antenna gain for a device with a single RF output shall be selected as the maximum in-band gain of the antenna across all operating bands, or 2 dBi, whichever is greater. However, for devices that operate in multiple frequency bands while using the same transmit antenna, the highest gain of the antenna within the operating band nearest in frequency to the restricted band emission being measured may be used in lieu of the overall highest gain when the emission is at a frequency that is within 20 percent of the nearest band edge frequency, but in no case shall a value less than 2 dBi be used. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 29 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB 5.9. Antenna Requirements 5.9.1 Standard Applicable According to antenna requirement of 15.203. An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this Section. The manufacturer may design the unit so that a broken antenna can be re-placed by the user, but the use of a standard antenna jack or electrical connector is prohibited. This requirement does not apply to carrier current devices or to devices operated under the provisions of Sections 15.211, 15.213, 15.217, 15.219, or 15.221. Further, this requirement does not apply to intentional radiators that must be professionally installed, such as perimeter protection systems and some field disturbance sensors, or to other intentional radiators which, in accordance with Section 15.31(d), must be measured at the installation site. However, the installer shall be responsible for ensuring that the proper antenna is employed so that the limits in this Part are not exceeded. And according to 15.247(4)(1), system operating in the 2400-2483.5MHz bands that are used exclusively for fixed, point-to-point operations may employ transmitting antennas with directional gain greater than 6dBi provided the maximum peak output power of the intentional radiator is reduced by 1 dB for every 3 dB that the directional gain of the antenna exceeds 6dBi. 5.9.2 Antenna Connected Construction 5.9.2.1. Standard Applicable According to 15.203, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. 5.9.2.2. Antenna Connector Construction The gains of antenna used for transmitting is -0.58dBi, and the antenna is a PCB antenna connect to PCB board and no consideration of replacement. Please see EUT photo for details. 5.9.2.3. Results: Compliance. Measurement The antenna gain of the complete system is calculated by the difference of radiated power in EIRP and the conducted power of the module. Conducted power refers ANSI C63.10:2013 Output power test procedure for DTS devices. Radiated power refers to ANSI C63.10:2013 Radiated emissions tests. Measurement parameters Measurement parameter Detector:
Sweep Time:
Resolution bandwidth:
Video bandwidth:
Trace-Mode:
Peak Auto 1MHz 3MHz Max hold Note: The antenna gain of the complete system is calculated by the difference of radiated power in EIRP and the conducted power of the module. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 30 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB Limits FCC ISED Antenna Gain 6 dBi Tnom Vnom Conducted power [dBm]
Measured with GFSK modulation Radiated power [dBm]
Measured with GFSK modulation Gain [dBi] Calculated Lowest Channel Middle Channel Highest Channel 2402 MHz 2440 MHz 2480 MHz
-5.733
-5.406
-6.288
-5.222
-0.511
-4.903
-0.503
-5.793
-0.495 Measurement uncertainty 1.6 dB (cond.) / 3.8 dB (rad.) This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 31 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB 6. LIST OF MEASURING EQUIPMENTS Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Equipment Manufacturer Model No. Serial No. Cal Date Due Date Power Meter Power Sensor Power Sensor Test Software RF Control Unit MXA Signal Analyzer DC Power Supply EMI Test Software 3m Semi Anechoic Chamber R&S R&S R&S Tonscend Tonscend Agilent Agilent AUDIX SIDT FRANKONIA NRVS NRV-Z81 NRV-Z32 JS1120-2 JS0806-2 N9020A E3642A E3 100444 100458 10057
/
N/A 2019-06-11 2020-06-10 2019-06-11 2020-06-10 2019-06-11 2020-06-10 N/A N/A 2019-06-11 2020-06-10 MY50510140 2019-06-11 2020-06-10 N/A
/
2018-11-15 2019-11-14 N/A N/A SAC-3M 03CH03-HY 2019-06-12 2020-06-11 Positioning Controller MF MF-7082 N/A 2019-06-12 2020-06-11 Active Loop Antenna By-log Antenna Horn Antenna Broadband Horn Antenna Broadband Preamplifier EMI Test Receiver RS SPECTRUM ANALYZER Broadband Preamplifier SCHWARZBEC K SCHWARZBEC K SCHWARZBEC K SCHWARZBEC K SCHWARZBEC K R&S R&S
/
FMZB 1519B 00005 2018-07-26 2019-07-25 VULB9163 9163-470 2018-07-26 2019-07-25 BBHA 9120D 9120D-1925 2019-07-01 2020-06-30 BBHA 9170 791 2018-09-20 2019-09-19 BBV 9719 9719-025 2018-09-20 2019-09-19 ESR 7 FSP40 101181 100503 2019-06-12 2020-06-11 2018-11-15 2019-11-14 BP-01M18G P190501 2019-07-01 2020-06-30 RF Cable-R03m Jye Bao RG142 CB021 2019-06-12 2020-06-11 RF Cable-HIGH SUHNER SUCOFLEX 106 03CH03-HY 2019-06-12 2020-06-11 6dB Attenuator 3dB Attenuator EMI Test Receiver Artificial Mains 10dB Attenuator
/
/
R&S R&S 100W/6dB 1172040 2019-06-11 2020-06-10 2N-3dB ESPI ENV216
/
2019-06-11 2020-06-10 101840 101288 2019-06-11 2020-06-10 2019-06-12 2020-06-11 SCHWARZBEC K MTS-IMP-136 261115-001-0032 2019-06-11 2020-06-10 Note: All equipment is calibrated through CHINA CEPREI LABORATORY and GUANGZHOU LISAI CALIBRATION AND TEST CO., LTD. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 32 of 33 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY Report No.: LCS190702116AEB 7. TEST SETUP PHOTOGRAPHS OF EUT Please refer to separated files for Test Setup Photos of the EUT. 8. EXTERIOR PHOTOGRAPHS OF THE EUT Please refer to separated files for External Photos of the EUT. 9. INTERIOR PHOTOGRAPHS OF THE EUT Please refer to separated files for Internal Photos of the EUT.
----------------THE END OF TEST REPORT---------------
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 33 of 33
1 2 | Label and Label Location | ID Label/Location Info | 101.90 KiB | July 08 2019 |
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY LABEL AND LOCATION Urbanista Sydney Model No.: Urbanista Sydney FCC ID: 2AJD8UN-SYDNEY U&I DC 3.7V by battery(600mA) Made in China Size: L2.5cm*W1.0cm Label Location This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 1
1 2 | Test Setup Photos | Test Setup Photos | 273.84 KiB | July 08 2019 |
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY 1. TEST SETUP PHOTOGRAPHS 1.1. Photo of Radiated Emissions Measurement Fig. 1 Fig. 2 _______________________________________________________________________________________________ SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AJD8UN-SYDNEY 1.2. Photo of Conducted Emissions Measurement Fig. 3 _______________________________________________________________________________________________
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2019-08-07 | 2402 ~ 2480 | DTS - Digital Transmission System | Original Equipment |
2 | 2019-08-06 | 2402 ~ 2480 | DSS - Part 15 Spread Spectrum Transmitter |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 | Effective |
2019-08-07
|
||||
1 2 |
2019-08-06
|
|||||
1 2 | Applicant's complete, legal business name |
Urbanista
|
||||
1 2 | FCC Registration Number (FRN) |
0025791500
|
||||
1 2 | Physical Address |
Master Samuelsgatan 10,SE-111 44
|
||||
1 2 |
Stockholm, 11144
|
|||||
1 2 |
Sweden
|
|||||
app s | TCB Information | |||||
1 2 | TCB Application Email Address |
b******@phoenix-testlab.de
|
||||
1 2 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 2 | Grantee Code |
2AJD8
|
||||
1 2 | Equipment Product Code |
UN-SYDNEY
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 | Name |
M**** W****
|
||||
1 2 | Title |
Product Manager
|
||||
1 2 | Telephone Number |
0046 ********
|
||||
1 2 | Fax Number |
0046 ********
|
||||
1 2 |
m******@urbanista.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 2 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 | Equipment Class | DTS - Digital Transmission System | ||||
1 2 | DSS - Part 15 Spread Spectrum Transmitter | |||||
1 2 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Urbanista Sydney (Bluetooth Speaker) | ||||
1 2 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 | Modular Equipment Type | Does not apply | ||||
1 2 | Purpose / Application is for | Original Equipment | ||||
1 2 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | Yes | ||||
1 2 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 | Grant Comments | Output power listed is peak conducted. | ||||
1 2 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 | Firm Name |
Shenzhen LCS Compliance Testing Laboratory Ltd.
|
||||
1 2 | Name |
G****** L******
|
||||
1 2 | Telephone Number |
0755-********
|
||||
1 2 | Fax Number |
0755-********
|
||||
1 2 |
g******@lcs-cert.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | CC | 2402.00000000 | 2480.00000000 | 0.0010000 | |||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 15C | CC | 2402.00000000 | 2480.00000000 | 0.0030000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC