600-1054-95R Simon XT Installation Manual Pb g Copyright Disclaimer Trademarks and patents Software license agreement Copyright 2007 GE Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without prior written consent from GE Security except where specifically permitted under US and international copyright law. Document number: 466-2265D (November 2007). The information in this document is subject to change without notice. GE Security, Inc. (GE Security) assumes no responsibility for inaccuracies or omissions and specifically disclaims any liabilities, losses, or risks, personal or otherwise, incurred as a consequence, directly or indirectly, of the use or application of any of the contents of this document. For the latest documentation, contact your local supplier or visit us online at www.gesecurity.com. This publication may contain examples of screen captures and reports used in daily operations. Examples may include fictitious names of individuals and companies. Any similarity to names and addresses of actual businesses or persons is entirely coincidental. GE and the GE monogram are registered trademarks of General Electric Company. Simon and Simon XT are trademarks of GE Security. Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products. This product and the use of this product may be covered by one or more of the following patents:
5,805,063; 5,872,512; 5,942,981; 5,686,896; 5,686,885; or 4,855,713. Important: This end-user license agreement (Agreement) is a legal agreement between GE SECURITY and You. Read the following terms and conditions carefully before installing or using this Software. This agree-
ment provides a license from GE SECURITY to use the Software. It also contains warranty information, dis-
claimers, and liability limitations. Installing and/or using the Software confirms Your agreement to be bound by these terms and conditions. If You do not agree with these terms and conditions, do not install or use the Software or, if already installed, immediately cease all use of the Software and promptly uninstall all compo-
nents of the Software. 1. Definitions. The following definitions apply to this document:
a. GE SECURITY, with respect to title to or warranty of the Software, means GE Security Inc., a Dela-
ware corporation. b. Software mean the executable software or firmware programs and accompanying documenta-
tion installed on the GE SECURITY products, plus any upgrades, modified versions, updates, addi-
tions, and copies of the software furnished to Customer during the term of the license granted herein. c. Documentation means all associated media, printed materials, and electronic documentation accompanying the Software. d. Licensed Product means the Software and Documentation. e. Customer means the person or organization, or parent or subsidiary thereof, who uses the Soft-
ware for its intended purposes, and excludes distributors, authorized resellers, value-added resellers and original equipment manufacturers. Customer may be referred to as You or Your, whether an individual or a business entity of any kind. f. Machine means the computer, workstation, terminal, or other hardware product on which the Software is installed. 2. License. All rights to and in the Licensed Product, including, but not limited to, copyrights, patents, trademarks, and trade secrets, belong to GE SECURITY, and GE SECURITY retains title to each copy of the Software. You agree that GE SECURITY at any time, upon reasonable notice, may audit Your use of the Software for compliance with the terms and conditions of this Agreement. Subject to the terms and con-
ditions of this Agreement, GE SECURITY grants You a nonexclusive license to use the Software, but only in the country where acquired, provided that You agree to the following:
You may:
a. install and use the Software on a single Machine at one time, unless You have purchased additional copies of the Software, in which case You may install the software on the number of Machines for which You have purchased copies of the Software;
b. use the original copy of the Software provided to You for backup purposes. You may not:
a. transfer or distribute the Licensed Product to others, in electronic format or otherwise, and this Agree-
ment shall automatically terminate in the event of such a transfer or distribution;
b. use the Software over a computer network;
c. sell, rent, lease, or sublicense the Software;
d. copy or modify the Licensed Product for any purpose, including for backup purposes. iii 3. Term. This Agreement is effective until terminated. You may terminate this Agreement by uninstalling all components of the Software from all Machines and returning the Software to GE SECURITY. GE SECURITY may terminate this Agreement if You breach any of these terms and conditions. Upon ter-
mination of this Agreement for any reason, You agree to uninstall all components of the Software and return the Licensed Product to GE SECURITY. All provisions of this Agreement relating to (i) disclaimer of warranties; (ii) limitations on liability, remedies, and damages; and (iii) GE SECURITYs proprietary rights, shall survive termination of this Agreement. 4. Object code. The Software is delivered in object code only. You may not alter, merge, modify, adapt, or translate the Software, nor decompile, disassemble, reverse-engineer, or otherwise reduce the Soft-
ware to a human-perceivable form, nor create derivative works or programs based on the Software. 5. Limited warranty. GE SECURITY warrants that for one (1) year from the date of delivery of the Licensed Product (Software Warranty Period), the functions contained in the Software will be fit for their intended purpose as described in the applicable Documentation from GE SECURITY, and will conform in all material respects to the specifications stated in such Documentation. GE SECURITY does not warrant that the operation of the Software will be uninterrupted or error-free. GE SECURITY does warrant that the media on which the Software is furnished will be free from defects in materials and workmanship under normal use for a period of thirty (30) days from the date of delivery (Media Warranty Period). Except as specifically provided therein, any other software and any hardware furnished with or accompanying the Software is not warranted by GE SECURITY. Your exclusive remedy under this limited warranty for nonconforming Software shall be repair or replace-
ment of the Software, at the sole discretion of GE SECURITY. To obtain a repair or replacement of noncon-
forming Software, contact GE SECURITY Customer Service toll-free at 888-GESECURity or online at www.gesecurity.com during the Software Warranty Period. Except as expressly provided above, the licensed product is provided as is without warranty of any kind, either expressed or implied, including, but not limited to, implied warranties of merchantability or fitness for a particular purpose and, except as expressly provided above, You assume the entire risk as to the quality and performance of the licensed product. 6. Limitation of liability. GE SECURITYs sole obligation or liability under this agreement is the repair or replacement of nonconforming software and/or defective media according to the limited warranty above. In no event will GE SECURITY be liable for damages, whether consequential, incidental, or indirect, nor for loss of data, loss of profits, or lost savings, arising from use or inability to use the software or docu-
mentation (or any hardware furnished with the software), even if GE SECURITY has been advised of the possibility of such damages, nor for any claim by any third party. 7. General. Any materials provided to You by GE SECURITY shall not be exported or reexported in viola-
tion of any export provisions of the USA or any other applicable jurisdiction. Any attempt to sublicense, assign, or transfer any of the rights, duties, or obligations hereunder shall be void. This Agreement shall be governed by and interpreted under the laws of the State of New York, United States of America, without regard to conflicts of law provisions. You hereby consent to the exclusive jurisdiction of the state and federal courts located in Multnomah County, Oregon, to resolve any disputes arising under or in con-
nection with this Agreement, with venue in Portland, Oregon. 8. Restricted rights legend. The Licensed Product is provided with RESTRICTED RIGHTS. In the event the United States Government or an agency thereof is granted a license, the following additional terms apply: Restricted Computer Software, as defined in the Commercial Computer SoftwareRestricted Rights clause at Federal Acquisition Regulations 52.227-19, and the restrictions as provided in subparagraphs
(c)(1) and (c)(2) thereof; and as applicable, the Governments rights to use, modify, reproduce, release, per-
form, display, or disclose the Software also are restricted as provided by paragraphs (b)(2) and (b)(3) of the Rights in Noncommercial Technical Data and Computer SoftwareSmall Business Innovative Research
(SBIR) Program clause at DFARS 252.227-7018. 9. Acknowledgment. You acknowledge that You have read and understand this agreement and agree to be bound by its terms. You further agree that this agreement is the complete and exclusive statement of the agreement between You and GE SECURITY, and supersedes any proposal or prior agreement, oral or written, and any other communication relating to the subject matter of this agreement. Intended use Use this product only for the purpose it was designed for; refer to the data sheet and user documentation. For the latest product information, contact your local supplier or visit us online at www.gesecurity.com. iv Simon XT Installation Manual FCC compliance This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interfer-
ence when the equipment is operated in a residential environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the affected equipment and the panel receiver to separate outlets, on different branch circuits. Consult the dealer or an experienced radio/TV technician for help. FCC Part 15 registration number: B4Z-910C-SIMON. Part 68. This equipment complies with Part 68 of the FCC rules and the requirements adopted by ACTA. A label on this equipment contains a product identifier in the format US:AAAEQ##TXXXX. You must provide this number to the telephone company upon request. FCC Part 68 registration number: US:B4ZAL02B55910. The plug and jack used to connect this equipment to the premises wiring and telephone network comply with the applicable FCC Part 68 rules and requirements adopted by ACTA. A compliant telephone cord and mod-
ular plug is provided with this product. It is designed to be connected to a compatible modular jack that is also compliant. See the installation instructions for details. The REN is used to determine the maximum number of devices that may be connected to your telephone line. Excessive RENs on a telephone line may result in devices not ringing in response to an incoming call. In most cases, the sum of all device RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to a line, as determined by the total RENs, contact your local telephone company. For products approved after July 23, 2001, the REN is part of the identifier with the format US:AAAEQ##TXXXX. The digits represented by ## are the REN without a decimal point. (For example, 03 is a REN of 0.3). For earlier products, the REN is separately shown on the label. Alarm dialing equipment must be able to seize the telephone line and place a call in an emergency situation. It must be able to do this even if other equipment (telephone, answering system, computer modem, etc.) already has the telephone line in use. To do so, alarm dialing equipment must be connected to a properly installed RJ31X jack that is electrically in series and ahead of all other equipment attached to the same tele-
phone line. If you have any questions concerning these instructions, consult your local telephone company or a qualified installer about installing an RJ31X jack and alarm dialing equipment for you. If this equipment causes harm to the telephone network, the telephone company may temporarily discon-
nect your service. The telephone company may notify you in advance, but when advance notice isnt prac-
tical, they will notify you as soon as possible and advise you of your right to file a complaint with the FCC. The telephone company may make changes in their facilities, equipment, operations, or procedures that could affect the operation of the equipment. If they do, they will notify you in advance so you can make the modifications to maintain uninterrupted service. This equipment may not be used on coin service provided by the telephone company. Connection to party line service is subject to state tariffs. Contact the state public utility commission, public service commission, or corporation commission for information. If you experience trouble with this equipment, please contact the company that installed the equipment for service and repair information. If the equipment is causing harm to the telephone network, the telephone company may ask you to disconnect the equipment until the problem is resolved. Contents v Chapter 3. Chapter 1. Tables. vii Preface. ix Conventions used in this document . ix Safety terms and symbols . ix Materials needed . ix Introduction . 1 Product overview. 2 System components . 3 Standard panel . 4 Chapter 2. Planning. 5 Planning the installation . 6 Control panel location. 6 Planning sensor types and locations . 6 System configuration . 11 Emergency planning. 16 Installing the system . 17 UL listed installations . 18 SIA system requirements . 19 Central station reporting . 20 UL Canada listed installations . 20 California state fire marshall listed installations. 21 Opening panel cover and chassis . 22 Mounting the panel. 23 Connecting hardwired devices. 24 HW1 I/O, HW2 in, and HW1&2 DC out terminals . 24 Interior sirens. 24 LD105 hardwired interior siren. 25 Hardwired contacts . 25 Wiring a phone line to the panel . 27 Full line seizure . 27 Wiring the power transformer . 30 Powering up the panel . 30 Installing X10 modules . 32 vi Simon XT Installation Manual Chapter 4. Programming . 33 Programming overview . 34 Entering and exiting the system menu . 35 Menu navigation . 36 Set clock . 38 Revision . 38 Contrast. 38 System programming. 39 Access codes . 40 Security . 41 Phone numbers. 43 Phone options . 43 Sensors . 45 Reporting . 47 Timers . 49 Touchpad options. 51 System options . 51 Siren options . 52 Piezo beep options. 53 Audio verification options . 54 Light control (optional) . 54 System tests. 57 Resetting memory to the factory defaults. 58 Chapter 5. Testing . 59 Control panel . 60 Sensor testing . 61 If a sensor fails the sensor test. 62 Phone communication . 63 Offsite phone operation . 63 Central station communication . 64 Two-way voice operation . 65 Voice event notification . 65 X10 operation . 66 Manual lamp module control . 66 X10 siren and lamp module functions . 66 Chapter 6. Troubleshooting and support. 67 Troubleshooting. 68 Contacting us . 70 Online resources. 70 Appendix A. Specifications and tables. 71 Specifications . 72 Sensor names. 72 Index . 75 Tables vii Supported devices..................................................................................................................................................................... 3 Table 1. Panel hardware capabilities.................................................................................................................................................. 4 Table 2. Recommended sensor groups ............................................................................................................................................. 7 Table 3. Sensor group characteristics................................................................................................................................................ 7 Table 4. Sensor assignments/locations ............................................................................................................................................. 9 Table 5. System programming menu options...............................................................................................................................11 Table 6. SIA setting requirements ......................................................................................................................................................19 Table 7. Nonprogrammable (hard coded) system operation ..................................................................................................20 Table 8. Simon XT panel keys and features....................................................................................................................................35 Table 9. Simon XT menu structure....................................................................................................................................................36 Table 10. Simon XT programming codes..........................................................................................................................................39 Table 11. Access codes.............................................................................................................................................................................40 Table 12. Security........................................................................................................................................................................................41 Table 13. Phone numbers ........................................................................................................................................................................43 Table 14. Table 15. Phone options ...........................................................................................................................................................................43 Table 16. Device programming .............................................................................................................................................................45 Sensors ........................................................................................................................................................................................46 Table 17. Table 18. Reporting options ....................................................................................................................................................................47 Timers...........................................................................................................................................................................................49 Table 20. Communication modes.........................................................................................................................................................49 Table 19. Touchpad options....................................................................................................................................................................51 Table 21. System options .........................................................................................................................................................................51 Table 22. Table 23. Siren options..............................................................................................................................................................................52 Panel piezo beeps....................................................................................................................................................................53 Table 24. Audio verification.....................................................................................................................................................................54 Table 25. Light control...............................................................................................................................................................................57 Table 26. Table 27. System tests ..............................................................................................................................................................................57 Control panel test sequence ...............................................................................................................................................60 Table 28. Arming levels.............................................................................................................................................................................60 Table 29. Table 30. Sensor tripping instructions ................................................................................................................................................61 Table 31. Minimum beeps........................................................................................................................................................................62 Phone commands ...................................................................................................................................................................63 Table 32. Sensor/user report codes.....................................................................................................................................................64 Table 33. Audio verification set..............................................................................................................................................................65 Table 34. Table 35. Alarm siren and X10 light information ...........................................................................................................................66 Technical support....................................................................................................................................................................70 Table 36. Simon XT specifications .......................................................................................................................................................72 Table 37. Alphabetical list of sensor name segments ..................................................................................................................72 Table 38. Table 39. Sensor name segments by index number (in scrolling order) ...............................................................................73 Simon XT system quick reference ....................................................................................................................................74 Table 40. viii Simon XT Installation Manual ix Preface This is the GE Simon XT Installation Manual for model 600-1054-95R. This document includes an overview of the product and detailed instructions explaining:
how to install; and how to set up the product for customer use. There is also information describing how to contact technical support if you have questions or concerns. To use this document effectively, you should have a basic knowledge of electrical wiring and low-voltage electrical connections. Read these instructions and all ancillary documentation entirely before installing or operating this product. The most current versions of this and related documentation may be found on our website. Refer to Online resources on page 70 for instructions on accessing our online publication library. Note: A qualified service person, complying with all applicable codes, should perform all required hardware installation. Conventions used in this document The following conventions are used in this document:
Bold Italic Menu items and buttons. Emphasis of an instruction or point; special terms. Blue italic Monospace File names, path names, windows, panes, tabs, fields, variables, and other GUI elements. Titles of books and various documents.
(Electronic version.) Hyperlinks to cross-references, related topics, and URL addresses. Text that displays on the computer screen. Programming or coding sequences. Safety terms and symbols These terms may appear in this manual:
CAUTION: Cautions identify conditions or practices that may result in damage to the equipment or other property. WARNING: Warnings identify conditions or practices that could result in equipment damage or serious personal injury. Materials needed Pencil Phillips screwdriver x Simon XT Installation Manual Chapter 1 Introduction This chapter provides an overview of the system and an outline of the steps you need to perform before you begin installing and configuring your security system. In this chapter:
Product overview. 2 System components . 3 Standard panel . 4 2 Simon XT Installation Manual Product overview This security system can be used as a fire warning system, an intrusion alarm system, an emergency notification system, or any combination of the three. The system (Figure 1) has three types of components:
Self-contained control panel Devices that report to the panel Devices that respond to commands from the panel Note: The keyfob and X10 modules have not been investigated by UL. Figure 1. Simon XT system Keyfob Door/window sensor PIR motion sensor Smoke detector Remote handheld touchpad X10 universal module X10 lamp module X10 appliance module Note: The universal, lamp, and appliance modules require a special transformer. The self-contained panel provides the main processing unit for all system functions. It receives and responds to signals from wireless sensors and wireless touchpads throughout the premises. For monitored systems, the panel can be connected to the premises phone line for central monitoring station reporting. You can program the panel onsite from the keypad or remotely using Enterprise Downloader software. See Programming on page 33 for complete onsite programming instructions. Chapter 1 Introduction 3 System components The system can monitor up to 40 sensors and may use any of the devices listed in Table 1. Table 1. Supported devices Device Description Door/window sensor
(60-670) For intrusion protection, install door/window sensors on all ground-floor doors and windows. At a minimum, install them in the following locations:
All easily accessible exterior doors and windows. Interior doors leading into the garage. Doors to areas containing valuables such as cabinets and closets. Indoor motion sensor
(60-639) Indoor motion sensors are ideal whenever it is not practical to install door/window sensors on every opening. Identify areas where an intruder is likely to walk through. Large areas in an open floor plan, downstairs family rooms, and hallways are typical locations for indoor motion sensors. For installations with pets, use the SAW Pet Immune PIR (60-807). Outdoor motion sensor
(60-639) Use outdoor motion sensors to detect motion in a protected outdoor area. Detected motion in this protected area can sound chimes or turn on outside lights. X10 module a When the panel is powered using the line carrier power transformer, the system can work with any of the following modules:
X10 lamp module (13-403) X10 appliance module (13-402) X10 power horn/remote siren module (13-398) Freeze sensor (60-742) a Freeze sensors detect low temperature conditions which may indicate a furnace failure. The sensor contains a bimetallic thermal switch connected to the built-in transmitter. The sensor transmits an alarm signal to the panel when the surrounding temperature drops to about 41F (5C). When the temperature rises to 50F (10C), the sensor transmits a restore signal. Water sensor (60-744) a Water sensors detect a water leak/rising water. The detector is connected to the sensor by an 8-
foot (2.4-meter) cable. Water that reaches both detector contact points activates the sensor, causing it to transmit an alarm signal. Smoke sensor (60-848-
95) Smoke sensors provide fire protection by causing an alarm to sound throughout the house. You can add smoke sensors near sleeping areas and on every floor of the house. Avoid areas that could have some smoke or exhaust such as attics, kitchens, above fireplaces, dusty locations, garages, and areas with temperature extremes. In these areas you may want to install Rate-of-Rise sensors to detect extreme temperature changes. Emergency planning on page 16 and the instructions packaged with the smoke sensor for complete placement information. Carbon monoxide (CO) alarm (60-652-95) a The Learn Mode CO alarm alerts users to hazardous levels of carbon monoxide gas. If dangerous concentrations of gas are present, the red indicator light comes on, the internal siren goes off, and an alarm is transmitted to the panel. The panel sounds its own alarm and reports to the central station. Keyfob (60-659) a The keyfob (keychain touchpad) lets you turn the system on and off from right outside the home or activate a panic alarm if there is an emergency. If you have X10 lamp modules, you can use keyfobs to turn all system controlled lights on and off. ELM (encrypted learn mode) keyfob (60-832) a The ELM (encrypted learn mode) 2-button keyfob is an alkaline battery-powered, wireless touchpad that allows users to arm and disarm their system, and activate a police or auxiliary panic alarm. Random encrypted signal transmissions provide high security to help prevent signal copying. 4 Simon XT Installation Manual Table 1. Supported devices (continued) Device Description Remote handheld touchpad (60-671) The remote handheld touchpad lets you turn the system on and off while in the home, turn system controlled lights on and off (all or individual lights), or activate a panic alarm if there is a nonmedical emergency. Water-resistant personal help button
(60-906-95) a The water-resistant personal help button is a wireless device used for activating police, medical or auxiliary alarms through your system. When the help button is pressed, the light mounted under the cover will blink and an alarm signal is transmitted. a. Devices noted have not been investigated for use in UL installations. CAUTION: Do not use outdoor motion sensors for intrusion protection. Standard panel Table 2 describes the basic panel (out-of-box) hardware capabilities. Table 2. Panel hardware capabilities Hardware Power Capability Input for an AC step-down, plug-in style transformer. One siren output, up to two zone inputs Terminals for connecting hardware sirens or normally closed (NC) loop switch circuits. Phone line connection Allows panel to communicate with central monitoring station and/or remote phone. Inspect the package and contents for visible damage. If any components are damaged or missing, do not use the unit; contact the supplier immediately. If you need to return the unit, you must ship it in the original box. n Chapter 2 Planning This chapter provides information to help you plan your installation to reduce time and costs. In this chapter:
Planning the installation . 6 Control panel location . 6 Planning sensor types and locations. 6 System configuration. 11 Emergency planning . 16 6 Simon XT Installation Manual Planning the installation This section describes system capabilities to help you get familiar with your system. The planning sheets contain tables that let you record the hardware and programming configuration of your system. Complete all of the information ahead of time to help prepare for system installation. Refer to Sensor names on page 72 for sensor name segments listed alphabetically and by index number. Control panel location Locate the panel where alarm sounds can be heard and where the panel will be easily accessible for operation. Do not install the panel near a window or door where it can be reached easily by an intruder. Planning sensor types and locations The first step to an easy and successful installation is to decide what areas or items to protect, which lights or appliances to operate, and the best location for the panel, touchpad, sensors, and sirens. Metal objects, mirrors, and metallic wallpaper can block signals sent by the wireless sensors. Make sure there are no metal objects in the way when installing the system. Use Table 3, Recommended sensor groups on page 7 and Table 4, Sensor group characteristics on page 7 to determine the appropriate sensor type for the sensors you will be adding. Use Table 5, Sensor assignments/
locations on page 9 to document the planned sensor information. You will need to understand the application for each sensor. For example, keyfobs are typically programmed as sensor group 01 (portable panic) and used to send an intrusion alarm to a central monitoring station. This sensor type is instant intrusion, it does not require restoral or supervisory communication with the panel and it is active in four arming levels:
1. Disarm. 2. Arm doors and windows. 3. Arm motion sensors. 4. Arm doors/windows and motion sensors. Table 3. Recommended sensor groups Device Recommended sensor group Indoor motion sensor 17 (intrusion), 25 (chime) Outdoor motion sensor 25 (chime only) Entry/exit door Interior door Window sensor Smoke Sensor Keyfob ELM keyfob 10 14 13 26 01, 03, 06, 07 01, 03, 06, 07 Remote Handheld Touchpad 01, 03, 06, 07 CO Alarm Freeze Sensor Water Sensor 34 29 38 Personal Help Button 01, 03 Table 4. Sensor group characteristics e p y T Name/application 00 Fixed panic: 24-hour audible fixed emergency button. y a e l Siren type D Intrusion I 01 Portable panic: 24-hour audible portable emergency buttons. Intrusion 02 Fixed panic: 24-hour silent fixed emergency buttons. Status light will not blink. Silent 03 Portable panic: 24-hour silent portable emergency buttons. Status light will not blink. 04 Fixed auxiliary: 24-hour auxiliary sensor. Silent Emergency 05 Fixed auxiliary: 24-hour emergency button. Siren shut off confirms CS report. Emergency 06 Portable auxiliary: 24-hour portable auxiliary alert button. 07 Portable auxiliary: 24-hour portable auxiliary button. Siren shut off confirms CS report. 08 Special intrusion: such as gun cabinets and wall safes. DTM (tamper only). 09 Special intrusion: such as gun cabinets and wall safes. 10 Entry/exit delay: A delay that requires a standard delay time. chime. 13 Instant perimeter: Exterior doors and windows. chime. 14 Instant interior: Interior doors. Emergency Emergency Intrusion Intrusion Intrusion Intrusion Intrusion I I I I I I I I S S I F Chapter 2 Planning 7 y r o s i v r e p u S l a r o t s e R Active In arming levels N Y 1234 N N 1234 N Y 01234 N N 01234 N Y 01234 N Y 01234 N N 01234 N N 01234 Y Y Y Y Y Y Y Y Y Y 1234 1234 24 24 234 8 Simon XT Installation Manual Table 4. Sensor group characteristics (continued) e p y T Name/application 15 Instant interior: Interior PIR motion sensors.a 16 Instant interior: Interior doors. 17 Instant interior: PIR motion sensors and Sound sensors.a 18 Instant interior: Cross-zone PIR motion sensors. y a e l Siren type D Intrusion F Intrusion Intrusion Intrusion 19 Delayed interior: Interior doors that initiate a delay before going into alarm. Intrusion 20 Delayed interior: PIR motion sensors that initiate a delay before going into alarm.a 21 Local instant interior: 24-hour local alarm zone protecting anything that opens and closes. No report. 22 Local delayed interior: same as group 21, plus activation initiates a delay before going into alarm. No report.a 23 Local instant auxiliary: 24-hour local alarm zone protecting anything that opens and closes. No report.b 24 Local instant auxiliary: 24-hour local alarm zone protecting anything that opens and closes. Sirens shut off at restoral. No report. a Intrusion Intrusion Intrusion Emergency Emergency 25 Local special chime: notify the user when a door is opened. b Three beeps 26 Fire: 24-hour fire, rate-of-rise heat, and smoke sensors.c 27 Lamp control or other customer feature. No report. b Fire Silent 28 PIR motion sensor, sound sensor, or pressure mat. RF thermostat. No report. b Silent 29 Auxiliary: freeze sensors. b 32 PIR motion sensor or sound sensor. No report. b 34 Carbon monoxide alarm. b 35 Entry/exit delay interior PIR motion. 36 Special Intrusion: such as gun cabinets and wall safes. Reports as tamper if tripped. b Trouble beeps Silent Emergency Intrusion Intrusion 37 Light switch control: X10 modules turn either on or off when a door is opened. b Silent 38 Auxiliary: water sensors. b 39 Local instant interior: 24-hour local alarm zone protecting anything that opens and closes. No report. 40 Local special chime. Trouble beeps Intrusion Three beeps a. b. c. This type is not certified as a primary protection circuit for UL-listed systems and is for supplementary use only. This type has not been investigated by UL. This type is required for UL-listed residential fire alarm applications. y r o s i v r e p u S Y Y l a r o t s e R Y Y N Y N Y Y Y N Y Y Y Y Y Y Y Y Y Active In arming levels 234 34 34 34 34 34 1234 1234 01234 01234 N Y 01234 Y Y Y Y 01234 01234 N Y 01234 Y Y 01234 N N 01234 Y Y 01234 F F F S S I S I I I I I I I I I S N Y 234 I I I I I Y Y 1234 N Y 01234 Y Y Y Y Y Y 01234 1234 01234 Table 5. Sensor assignments/locations Sensor # Device Sensor group Sensor name/location Notes Chapter 2 Planning 9 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 10 Simon XT Installation Manual Table 5. Sensor assignments/locations (continued) Sensor # Device Sensor group Sensor name/location Notes 31 32 33 34 35 36 37 38 39 40 Cross-zoning Cross-zoning (two-trip) refers to two different group 18 sensors that must be tripped within two minutes of each other to report an alarm to the central station. Figure 2 shows the path of a person walking from the kitchen to the living room. When the person is detected walking through the kitchen, the motion sensor in the kitchen is tripped, sounding a local alarm. If motion is detected by the living room motion sensor within two minutes, an alarm report will be sent to the central station. Figure 2. Cross-zone diagram Motion sensor Path of person walking Motion sensor Note: We do not recommend cross-zoning for exit/entry zones. Each zone can individually protect the intended area. Chapter 2 Planning 11 System configuration Table 6 is a worksheet for you to record the desired values for each programming option. For each option, the default value, effect of deletion (pressing DISARM while editing), range, and programming privilege are also listed. Each option is described in more detail in on page 33. Table 6. System programming menu options Function Default Delete Range Access code a Installer settings Access codes menu Dealer code Installer code Master code User code 1 User code 2 User code 3 User code 4 User code 5 User code 6 User code 7 User code 8 Duress code Code length 654321, 54321, 4321, or 321 654321, 54321, 4321, or 321 123456, 12345, 1234, or 123 None None None None None None None None None 4 None None None None None None None None None None None None 4 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 D D, I D, I, M D, I, M D, I, M D, I, M D, I, M D, I, M D, I, M D, I, M D, I, M D, I, M D 12 Simon XT Installation Manual Table 6. System programming menu options (continued) Function Default Delete Range Access code a Installer settings 00000 12345 00000 12345 0 to FFFFFFFFFF 00000 to 99999 Security menu Account number Downloader code b Phone lock Autoarm (must be added for UL listed systems) Exit extension (must be deleted for UL listed systems) Secure arming No arm low battery Quick exit (must be disabled for UL listed systems) Downloader enable b Supervisory protest b Phone # menu Phone #1 Phone #2 Phone #3 Phone #4 Downloader number b Phone options menu Manual phone test Fail to communicate (must be added for UL listed systems) Off On On Off Off Off On Off None None None None None On On Off Off Off Off Off Off Off Off None None None None None Off Off DTMF On (Touchtone) Off (Pulse) 300 bps baud rate On (300 bps) Off (110 bps) Ring/hang/ring b 1 Dial delay 30 seconds Call waiting code None Off 15 sec. None On/Off On/Off On/Off On/Off On/Off On/Off On/Off On/Off 26 digits 26 digits 26 digits 26 digits 26 digits On/Off On/Off On/Off On/Off 1 to 7, Off 15 to 45 sec. 26 digits D, I D D D, I D, I D, I D, I D, I D, I, M D, I D D D, I D, I, M D, I D, I D, I D, I D, I D, I D, I D, I Table 6. System programming menu options (continued) Function Default Delete Range Chapter 2 Planning 13 Access code a Installer settings Sensors menu Learn sensors Delete sensors Edit sensors Reporting menu Report options Opening reports Closing reports Forced armed AC power failure report
(must be added for UL listed systems) Low CPU battery report
(must be added for UL listed systems) Off Off Off Off On Sensor alarm restoral report Off 24-hour sensor tamper report Off Supervisory/tamper report b Off No usage b Swinger shutdown Programming report Fire alarm verification Report communication modes Phone 1 report mode Phone 2 report mode Phone 3 report mode Phone 4 report mode Off On Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off D, I D, I D, I D, I D, I D, I D, I D, I D, I D, I D, I D, I D, I D, I D, I D D D, I D, I On/Off On/Off On/Off 5 to 254 minutes, Off On/Off 1 to 3, Off On/Off On/Off 2 to 254 days, Off On/Off On/Off On/Off ALL SIA ALL CID Alarms SIA Alarms CID Nonalarms SIA Nonalarms CID Backup SIA Backup CID Voice dialer Off 14 Simon XT Installation Manual Table 6. System programming menu options (continued) Function Default Delete Range Access code a Installer settings Timers menu Latchkey time b Entry delay (must be 45 seconds for UL listed systems Exit delay (must be 60 seconds for UL listed systems) No activity timeout b Auto phone test (must be set to 1 for UL listed systems) None None 12:00 midnight to 11:59 PM, None D, I, M 30 sec. 30 sec. 30 to 240 sec. 60 Seconds 45 sec. 45 to 254 sec. Off Off Off Off 2 to 24 hours 1 to 254 days Supervisory time Midnight None 12:00 midnight to 11:59 PM, None Alarm cancel RF timeout (supsync) (must be set to 4 for UL 985 & 1635 listed systems, or 24 for UL 1023 listed systems) Fail to open time b Fail to close time b Siren timeout (must be greater than 4 minutes for UL listed systems) Arming LED shutdown Unvacated premises Smoke supervision (must be disabled for UL listed systems) Touchpad options menu Keyfob no delay b Panic alarms b Remote touchpad arming b 6 minutes 12 hours Off 12 hours 6 to 255 minutes, Off 2 to 36 hours Off Off Off Off 12:00 midnight to 11:59 PM, Off 12:00 midnight to 11:59 PM, Off 5 minutes Off - No timeout 2 to 254 minutes, Off Off On Off Off On Off Off Off Off Off Off Off On/Off On/Off On/Off On/Off On/Off On/Off D, I D, I D, I D, I D, I D, I D, I D, I D, I D, I D, I D, I D, I D, I D, I D, I Table 6. System programming menu options (continued) Function Default Delete Range Chapter 2 Planning 15 Access code a Installer settings System options menu RF Jam detect (must be added for UL listed systems) Demo mode b HW1 function 24-hour clock Siren options menu Panel piezo beeps (must be on for UL listed systems) Panel voice Panel piezo alarms (must be added for UL listed systems or a siren must be connected Trouble beeps (must be added for UL listed systems) Voice chime Off Off 1 Off On On On On Off Status beeps volume 7 Hardwired siren supervision Off Speaker volume Panel silent police panic Panel tamper alarm Alarm report verification 8 Off Off Off Off Off Off Off Off Off Off Off Off 7 Off 8 Off Off Off On/Off On/Off 1 - Interior siren output 2 - Output activated when armed 3 - Output activated when disarmed 4 - FTC output (FTC must be on) 5 - Output activated for alarm Off - No output On/Off On/Off On/Off On/Off On/Off Off - No voice chime 1 - Voice chime (sensor name) 2- Chime bell 3- Soft chime bell 1 - 10 On/Off 1 to 8 On (silent), Off (audible) On/Off On/Off D, I D, I D D, I D, I, M D, I, M D, I, M D, I D, I D, I, M D, I D, I, M D, I D, I D, I 16 Simon XT Installation Manual Table 6. System programming menu options (continued) Function Default Delete Range Access code a Installer settings Off Off Off 6 24 64 64 Off Off None A None Off Off Off 6 24 64 64 Off Off None A None Audio verify menu Audio mode b Fire shutdown b Panic talk b Vox receiver gain b Vox mic gain b Vox mic gain range b Manual mic gain b Light control menu Set entry lights b Sensor light b Light schedule b Housecode b Lock interval b System test menu Sensor test Communication test System download b Off - Audio mode disabled 1 - Instant mode 2 - Callback mode On/Off On/Off 1 to 32 1 to 64 1 to 64 1 to 64 On/Off for each unit number from 1 to 8 1 to 8, Off HH:MMx for start and stop times, None A to O HH:MMx for start and stop times, None D, I D, I D, I D, I D, I D, I D, I D, I, M D, I, M D, I, M D, I, M D, I, M D, I, M D, I, M D, I, M a. b. This column tells what type of access code is allowed to make changes: D = dealer code, I = installer code, M = master code. Not investigated for use by UL. Emergency planning Use these guidelines when drawing an emergency floor plan for the homeowner:
Show all building levels. Show exits from each room. (We recommend two exits per room.) Show the locations of all security system components. Show the locations of any fire extinguishers. Chapter 3 Installing the system This section describes how to open the panel for mounting, mount the panel, connect sirens, connect hardwired contacts, and connect the AC power transformer. In this chapter:
Opening panel cover and chassis . 22 Mounting the panel . 23 Connecting hardwired devices. 24 HW1 I/O, HW2 in, and HW1&2 DC out terminals. 24 Interior sirens . 24 LD105 hardwired interior siren . 25 Hardwired contacts. 25 Wiring a phone line to the panel . 27 Full line seizure. 27 Wiring the power transformer . 30 Powering up the panel . 30 Installing X10 modules . 32 18 Simon XT Installation Manual UL listed installations Some installations may require configurations dictated by city/state codes, insurance, or Underwriters Laboratories (UL). This section describes the various component and configuration listings. Basic system:
Control panel: backup battery 6 V 1.2 Ah (34-025) (Portalac model # PE6V1.2) Hardwired siren (13-374) Standard class 2, 9 VAC, 3.34 A power transformer (GE model # 22-153). Household burglary alarm system unit (UL 1023), basic system plus the following:
Panel piezo beeps set to on Entry delay set to 45 seconds or less Exit delay set to 60 seconds or less Hardwired magnetic contact (13-068 or 13-071) or wireless learn mode door/window sensor (60-670) RF time-out set to 24 hours Control panel alarms turned on Autoarm set to on Siren timeout set to five minutes or more Trouble beeps set to on RF jam detect set to on Hardwired siren supervision set to on Quick exit set to off Exit extension set to off Household fire warning system (UL 985), basic system plus the following:
Panel piezo beeps turned on Wireless smoke sensor 60-848-95 learned into sensor group 26 Control panel alarms set to on Siren timeout set to four minutes or more Trouble beeps set to on RF jam detect set to on Hardwired siren supervision set to on Smoke supervision must be set to on UL 1023 & 985 24-hour backup:
For 24-hour backup, the total current draw for all connected devices is limited to 250 mA (during normal standby conditions) using a 1.2 AH battery. UL 1635 digital alarm communicator system:
Same as UL 1023 & 985, plus:
Chapter 3 Installing the system 19 The following settings are in addition to UL 1023 and 985 and are required only if the system is set up for central station reporting. Phone mod 1 set to zero or one. Automatic phone test set to 001. RF timeout set to four hours. AC power failure report set to on. CPU low battery report set to on. Fail to communicate set to on. Entry delay plus the dialer delay must not exceed 60 seconds. SIA system requirements SIA system requirements are the same as those described for a UL listed basic system on page 1, plus:
If multiple annunciation is required, use hardwired siren part no.13-046. Note: UL requirements take priority over SIA requirements. Entry delay must not exceed 60 seconds. SIA setting requirements Table 7 describes programming requirements to meet ANSI-SIA CP-01 (see System programming on page 39). Note: Call waiting services should be disabled to prevent interrupting panel communication to the central monitoring station.. Table 7. SIA setting requirements Function Entry delay Exit delay Dialer delay Autoarm Programming page reference Default setting Required setting Table 20 on page 49 30 seconds Table 20 on page 49 60 seconds 30 to 240 seconds 45 to 240 seconds Table 15 on page 43 30 seconds 15 to 45 seconds Table 13 on page 41 Unvacated premises Table 20 on page 49 Call waiting Table 15 on page 43 On On Off On On On if reporting to central station and customer has call waiting service Exit extension Table 13 on page 41 On On Swinger shutdown Table 18 on page 47 On (one trip) On (one trip) Fire alarm verify Table 18 on page 47 Off Duress/panic code Table 23 on page 52 Disabled On Disabled Cross zone Cross-zoning on page 10 Disabled Disabled for zones with high probability of false alarms. 20 Simon XT Installation Manual Table 8 describes nonprogrammable (hard-coded) system operation, as required to meet ANSI-SIA CP-01, and is provided only for your reference. Table 8. Nonprogrammable (hard coded) system operation Function Silent exit Remote arming exit time and progress annunciation Operation All annunciators enabled All annunciators enabled Abort annunciation Cancel report annunciation Enabled Enabled Recent closing Exit error Restoration of power Enabled (2 minute window) Enabled Panel resumes operation in same arming state and disregards alarm signals from sensors for the first 60 seconds after power restoration Cancel alarm Enter code only. Central station reporting The panel has been tested with the following central station receivers using SIA and Contact ID reporting formats:
Note: Before beginning installation, installers must verify compatibility with the following central station receivers. Radionics D6600 central station receiver Sur-Gard central station receiver with models SG-DRL2A and SG-CPM2 CS5000 digital alarm communicator receiver UL Canada listed installations This section describes the requirements for CUL (UL Canada) listed installations. Canadian standards CSA certified accessories Standard Class 2, 9 VAC, 3.34 A power transformer (GE Security model 22-153-CN). Residential burglary alarm system unit (ORD-C1023-1974) Basic system as described for UL 1023 listed installations plus:
Hardwired magnetic contact (13-068 or 13-071) or wireless learn mode door/window sensor (60-670) Siren timeout set to six minutes or more Chapter 3 Installing the system 21 Residential fire warning system control unit (ULC-S545-M89) Basic system as described for UL 985 listed installations plus:
Wireless smoke sensor 60-848-95 learned into sensor group 26 Siren timeout set to six minutes or more For 24-hour backup, the total current draw for all connected devices is limited to 250 mA (during normal standby conditions) using a 1.2 AH battery. California state fire marshall listed installations Applied for. 22 Simon XT Installation Manual Opening panel cover and chassis Tabs at the top of the panel secure and release the front cover and the chassis. The plastic hinges on the panel bottom allow the cover and chassis to swing down and out of the way (Figure 3). Figure 3. Opening the panel cover and chassis Back piece Hinge Chassis Hinge Pb Tabs Chapter 3 Installing the system 23 Mounting the panel To mount the panel on a wall, do the following:
1. Choose a panel location. 2. Run all necessary power, phone, siren, and hardwired contact wires to the desired panel location. Note: When choosing the AC outlet location for the AC power transformer, make sure the outlet is not controlled by a switch or that it is not part of a ground fault circuit interrupt (GFCI). 3. Hold the panel against the wall and mark the mounting hole locations with a pencil. 4. Mount the back piece to the wall through the two horizontally centered mounting holes near the top and bottom using the supplied mounting hardware. Use wall anchors if no studs are present (Figure 4). Figure 4. Panel mounting hole locations Mounting hole Back piece 5. Connect the chassis assembly to the mounted back piece and let it hang down. This makes the terminal strip accessible for wiring various hardwired components to the panel. Mounting hole 6. Feed wires through openings in the back piece to be ready to attach them to the screw terminals or the phone connectors. Install all screws and tighten gently. 7. 24 Simon XT Installation Manual Connecting hardwired devices The panel has seven screw terminals and two telephone connections (Figure 5). The screw terminals connect AC power, sirens, and/or hardwired detectors. Program sensors and devices before you install them. Follow the instructions in to add the sensors to panel memory. Figure 5. Simon XT terminal connections HW2 in 9 VAC in HW1&2 DC out Battery + pos RJ45 connector (LINE) HW1 I/O Battery neg RJ11 connector (PHONE) Battery compartment Tamper switch HW1 I/O, HW2 in, and HW1&2 DC out terminals The HW1 I/O terminal is dual purpose and can be used for either siren or hardwired contact connections. The HW2 in terminal is an input only. Interior sirens From the factory, the HW1 I/O input is set up for interior siren operation (status and alarm sounds). HW1&2 DC out provides the positive (+) voltage. Note: The total current available from the HW1&2 DC out terminal is 250 mA at up to 120F (49C). A 24-hour battery standby for UL Requirements will be met with a maximum load of 250 mA. With Hardwired Siren Supervision turned on, sirens connected to HW1 I/O are supervised and require a 4.7 kohm resistor in the circuit. If this terminal is not used, turn Hardwired Siren Supervision off. Chapter 3 Installing the system 25 LD105 hardwired interior siren Interior sirens must always be wired with a resistor in the circuit. For circuit supervision which allows the panel to detect if the siren wire is cut (open), Hardwired Siren Supervision must be turned on. (See on page 33). Note: Do not install the resistor at the panel terminals. This does not provide supervision of the wire. Connect the LD105 hardwired interior siren (13-374) to the panel using a 4.7 kohm resistor (included with the siren) as shown in Figure 6. The resistor must be connected across the siren wires as close to the siren as possible. Figure 6. Hardwired interior siren with supervision 4.7 kohm resistor
(located at siren) Black Red O
/
I 1 W H 2
&
1 W H t u o C D n i 2 W H n i C A V 9 n i C A V 9
+
y r e t t a B
-
y r e t t a B Hardwired contacts To set up HW1 I/O and/or HW2 in for hardwired contacts, make the required connections as described under below, then proceed to the Programming on page 33 to add (learn) them into panel memory. You can connect hardwired reed switches (normally closed loop only) to HW1 I/O (if not being used for a hardwired siren) and/or HW2 in. Note: Connect only normally closed (NC) reed switches to HW1 I/O and/or HW2 in. Other types of hardwired detectors should not be used. The total resistance of the wire loop must not exceed 3 ohms. This allows you to use up to 200 ft. (61 m) of two-conductor, 22-gauge stranded wire. Connect hardwired reed switches to the panel using a 47 kohm resistor (not a 4.7 kohm resistor) as shown in Figure 7. The resistor must be connected at the last switch in the circuit. 26 Simon XT Installation Manual Note: Do not install the resistor at the panel terminals. This does not provide supervision of the wire. Figure 7. Connecting normally closed hardwired reed switches 47 kohm resistors O
/
I 1 W H 2
&
1 W H t u o C D n i 2 W H n i C A V 9 n i C A V 9
+
y r e t t a B
-
y r e t t a B Chapter 3 Installing the system 27 Wiring a phone line to the panel You can connect a phone line to the panel for systems monitored by a central monitoring station or systems that notify users by a voice event notification. DSL (digital subscriber line) allows the use of multiple devices on a single phone line simultaneously. For DSL environments, connect the panel line-in jack to an available phone jack on the premises. You might also need an inline filter to ensure panel reporting is successful. Note: Avoid connecting the panel to a standard phone (voice) line in this manner. Other devices in use at the same time the panel is using the line can prevent reports from going through. Full line seizure Full line seizure allows the panel to take over (seize) the phone line, even if another device on the line is in use. This method requires that the panel be wired before all other phones, answering machines, computers, or other devices on the phone line. You may need to verify line seizure for UL installations. Use the RJ31X (CA-38A) jack (Figure 8 on page 28) when wiring for full line seizure. This lets the user quickly and easily disconnect the panel from the phone line in case the panel disables the phone line due to a malfunction. Full line seizure wiring with an RJ31X 1. Run a four-conductor cable A from the premises Telco block D to the RJ31X B. 2. Connect the four-conductor cable A wires to the RJ31X B. 3. Disconnect the green and red premises phone jack wires from the Telco block D and splice them C to the four-conductor cable A black and white (or yellow) wires. Use weatherproof wire connectors for these splices. 4. Connect the four-conductor cable A green and red wires to the Telco block D TIP (+) and red to RING
() posts. 5. Connect the phone cord E included with the panel to the RJ31X B and the panel LINE jack. 28 Simon XT Installation Manual Figure 8. Full line seizure wiring with RJ31X E Pb BRN GRY B GRN RED k c a B l n e e r G d e R e t i h W
) w o l l e Y r o
(
TIP RING
(+)
(-) D A Green Black Green C Red White (or Yellow) Red Full line seizure wiring with one premises phone If a single phone is all that exists on the premises, full line seizure can be accomplished without an RJ31X
(Figure 8 on page 29). Chapter 3 Installing the system 29 1. Disconnect the phone from the premises phone jack and plug it into the panel PHONE jack A. This jack is disconnected automatically whenever the panel reports. 2. Connect the included phone cord to the panel LINE jack and the premises phone jack B. Note: If customers add phones or other phone devices to another phone jack, full line seizure no longer exists. Inform them to contact you if they want to add a phone or other device so that you can rewire for full line seizure by adding an RJ31X. Figure 9. Full line seizure wiring with single landline phone Line premises phone A B Premises phone jack Pb 30 Simon XT Installation Manual Wiring the power transformer Connect the power transformer to the panel AC terminals as shown in Figure 10. Figure 10. Transformer connections O
/
I 1 W H 2
&
1 W H t u o C D n i 2 W H n i C A V 9 n i C A V 9
+
y r e t t a B
-
y r e t t a B Note: Do not plug in the transformer at this time Powering up the panel When applying power to the panel connect the battery first, then plug in the AC power transformer. This sequence prevents a battery fault condition. Note: Maximum battery charge current is 60 mA. It may take up to 24 hours for a new battery to fully charge. Installing the backup battery To install the backup battery (6 VDC, 1.2 Ah), do the following:
1. Connect the lug end of the red battery lead to the red battery tab. 2. Connect the lug end of the black battery lead to the black battery tab. 3. Align the red (+) battery terminal with the right end of the terminal strip. The logo and specification information should be readable. Insert the front end of the battery under the forward battery compartment latch. 4. 5. Push forward and rotate the battery downward until it seats beneath the rear battery compartment latch. CAUTION: Do not connect the battery until you are ready to power up the panel. See Powering up the panel on page 30. Chapter 3 Installing the system 31 Figure 11. Installing the panel backup battery Pb Applying AC power Make sure the outlet is not controlled by a switch or that it is not part of a ground fault circuit interrupt (GFCI). 1. Remove the center screw from the outlet cover plate and hold the cover plate in place. WARNING: Use extreme caution when securing the transformer to a metal outlet cover. You could receive a serious shock if a metal outlet cover drops down onto the prongs of the plug. 2. Plug the transformer into the lower receptacle of the outlet so that the hole in the transformer tab lines up with the outlet cover screw hole. Insert the cover plate screw through the transformer tab and the outlet cover plate. Tighten the screw. 3. 32 Simon XT Installation Manual Installing X10 modules To install lamp and appliance modules, do the following:
1. Set the unit code dial to a unit number between 1 and 8. 2. Set the housecode for the installation. 3. Plug the module into a wall outlet. 4. Plug the lamp/appliance into the module. CAUTION: Do not plug in appliances or lamps with 300-watt or larger bulbs into Lamp Modules To install universal modules, do the following:
1. Set the unit code dial to a unit number different from all other X10 modules (between 1 and 8). 2. Set the housecode for the installation. 3. Set the module switches to momentary and relay only. 4. Connect the module terminals to the desired device terminals. 5. Plug the universal module into a wall outlet. Chapter 4 Programming This chapter provides steps on how to program your unit. In this chapter:
Programming overview . 34 Entering and exiting the system menu . 35 Menu navigation . 36 Set clock . 38 Revision. 38 Contrast. 38 System programming . 39 Access codes . 40 Security . 41 Phone numbers . 43 Phone options . 43 Sensors . 45 Reporting. 47 Timers . 49 Touchpad options . 51 System options. 51 Siren options . 52 Piezo beep options . 53 Audio verification options. 54 Light control (optional). 54 System tests . 57 Resetting memory to the factory defaults . 58 34 Simon XT Installation Manual Programming overview The control panel Figure 12 provides the main processing unit for all system functions. The programming of system options and features is menu-driven. All installer options are set in the System Programming menu, except for setting the system time. Table 9 on page 35 explains the panel keys and features shown in Figure 12. Figure 12. Simon XT self-contained panel MOTIONS DISARM DOORS+WINDOWS STATUS Piezo siren LCD display Emergency Police Microphone Fire Lights on Scroll up Enter Scroll down SILENT BYPASS Number keypad Speaker Lights off Door Chapter 4 Programming 35 Table 9. Simon XT panel keys and features Control Piezo siren Description The piezo siren makes alarm beeps and status beeps. Fire and intrusion alarm beeps are always played at high volume, while the volume of status beeps (such as trouble or chime beeps, entry and exit delay beeps, or auxiliary alarm beeps) is programmable. LCD display The LCD module has a 2 x 16 character array that displays a variety of phrases and icons. DOORS + WINDOWS Press to arm perimeter sensors. MOTIONS DISARM STATUS SILENT BYPASS Police Emergency Fire Press to arm interior sensors. Press to turn off intrusion/burglary protection for your system. Only intrusion/burglary sensors such as doors, windows, and motion sensors are disarmed. Environmental sensors, such as smoke and carbon monoxide, stay active at all times. Press to determine system status. Press to silence exit beeps when arming. Press to bypass a sensor. Press and hold the Police button for two seconds (or press twice quickly) to call the central monitoring station and notify them of a nonmedical call for help. Press and hold the Emergency button for two seconds (or press twice quickly) to call the central monitoring station and notify them of a nonmedical call for help. Press and hold the Fire button for two seconds (or press twice quickly) to call the central monitoring station and notify them of a nonmedical call for help. Microphone Used to communicate with central monitoring station after an alarm. Scroll up/scroll down Press to scroll through lists of similar items. Enter Press to select a particular menu item or commit to memory a menu item that has just been programmed. Numeric keypad Twelve-key telephone-type keypad (0 through 9, *, #) for entering access codes or other numerical data. Speaker Door
*
#
Provides voice output and sounds key beeps. The panel speaks arming level changes, system status, and voice chime sensor trips. The panel voice is also used for voice reporting and remote phone control. Covers the lower panel. Lights on. Lights off. Entering and exiting the system menu To enter the system menu, press either the scroll up/down or enter buttons in the upper right of the panel. Press the STATUS button to exit a menu or option edit mode and navigate up one level. Pressing the STATUS button while in the top menu level exits the system menu level. The panel automatically exits the system menu after a few seconds of inactivity if no access code has been entered yet. After an access code has been entered to access a code-protected area of the system menu, the timeout is 4 minutes. 36 Simon XT Installation Manual Menu navigation Each menu contains a list of options and/or submenus. Press the scroll up/down buttons to navigate up and down the list of options and submenus in that menu. Pressing the Enter key after navigating to an option selects that option for editing and flashes the current value. Pressing the Enter key after navigating to a submenu enters that submenu, making a new list of options accessible. Pressing STATUS exits a menu and goes to the next higher level. Programming options are arranged in a menu structure as outlined in Table 10. The top menu contains several features, as well as the System programming menu. When accessing the System programming or System tests menu, the panel prompts you to enter an access code. To continue, enter the dealer code or installer code, then press Enter. To program an option, first navigate to that option until it is displayed, then press Enter. The option value will start flashing, indicating that it is ready to be changed. Use the scroll keys or enter a numerical value to change the option, then press the Enter key to save the change. Table 10. Simon XT menu structure System time Enable scheduled lights Enable sensor-activated lights Enable chime Enable special chime System tests Sensor test Communication test Initiate download call System programming Access codes Dealer code Installer code Master code User code 1 User code 2 User code 3 User code 4 User code 5 User code 6 User code 7 User code 8 Duress code Code length Security Account number Downloader code Phone lock Autoarm Exit extension Secure arming No arm on panel low battery Quick exit Downloader enable Supervisory protest Phone #s Phone #1 Phone #2 Phone #3 Phone #4 Downloader phone number Phone options Manual phone test Fail to communicate DTMF dialing 300 bps baud rate Ring/hang/ring Dialer delay Call waiting code Chapter 4 Programming 37 Table 10. Simon XT menu structure (continued) Sensors Learn sensor Delete sensor Edit sensor Reporting Report options Opening report Closing report Force armed report AC power failure report Panel low battery report Sensor alarm restoral report 24-hour sensor tamper Supervisory/tamper report No usage report Swinger shutdown Programming report Fire alarm verification Communication modes Phone 1 reports Phone 2 reports Phone 3 reports Phone 4 reports Timers Latchkey time Entry delay Exit delay No activity timeout Auto phone test Supervisory time Alarm cancel window RF timeout Fail to open time Fail to close time Siren timeout Arming LEDs shutdown Unvacated premises Smoke sensor supervision Touchpad options Keyfob no delay Panel panic alarms Remote touchpad arming System options RF jam detect Demo mode HW1 I/O 24-hour clock format Siren options Panel piezo beeps Panel voice Panel piezo alarms Trouble beeps Voice chime Status beep volume Hardwired siren supervision Speaker volume Panel silent police panic Panel tamper Alarm report verification Audio verification Audio mode Fire shutdown Panic talk VOX receiver gain VOX microphone gain VOX gain range Manual microphone gain Light control Set entry lights Sensor lights Light schedules Housecode Lock interval System tests Sensor test Communication test Initiate download call Revision Contrast 38 Simon XT Installation Manual Set clock If the panel loses both AC and battery power, then upon restoring power the system time will reset to midnight and blink, indicating it has not been set correctly. You can set the system time to display in either 12-hour or 24-hour format. Time of day format is HH:MMx, where:
HH = 01 to 12 (12-hour format) or 00-23 (24-hour format) MM = 00 to 59 x = a or p (12-hour format) or none (24-hour format) To reset the clock:
1. Scroll up/down until the display shows Set clock. 2. Press Enter. 3. The display shows Enter code. 4. Enter your code with numeric keys. Press Enter. 5. Press Enter. The display now flashes the hours. 6. Scroll up/down to set the hours. 7. Press the Enter key to accept. The display now flashes the minutes. 8. Scroll up/down to set the minutes. 9. Press the Enter key to accept. The display is now flashing the AM/PM. 10. Scroll up/down to set the AM/PM. 11. Press Enter to accept. The display now shows the current time, and stops flashing. 12. Press the STATUS button twice to exit. Revision To display the firmware revision of the system:
1. Scroll up/down to Revision. 2. Press the STATUS button to exit. Contrast To adjust the Contrast of the display:
1. Scroll up/down to Contrast. 2. Press the Enter button. 3. Scroll up/down to increase and decrease the contrast setting. 4. Press the STATUS button to save the setting and exit. Note: Changes in contrast are more noticeable when not looking at the display straight-on. Chapter 4 Programming 39 System programming To enter system programming mode, do the following:
1. Press the scroll buttons until the panel displays System programming. 2. Press Enter. The system prompts for an access code. 3. Enter the access code from the codes listed in Table 11. The system displays each entered access code digit as an asterisk. 4. Press Enter. The panel is now in program mode. Note: Do not remove panel power while in program mode. Table 11. Simon XT programming codes Code Description Dealer code You can use the dealer code to program all system options, including high-security options that are not accessible with the installer code if it is different from the dealer code. Depending on how the access code is set, the default dealer access code is 654321, 54321, 4321 (factory default), or 321. This code can be used for all programming. Installer code Depending on how the access code is set, the default installer code is 654321, 54321, 4321 (factory default), or 321. This code is limited to changing all but the following: Dealer code, Code length, Downloader code, Phone lock, Phone #1, Phone #2, Phone 1 report mode, Phone 2 report mode, HW 1 function. 40 Simon XT Installation Manual Access codes Table 12. Access codes Function Default Description Dealer code 4321 Installer code 4321 Master code 1234 User codes 1 to 8 Blank You can use the dealer code to program all system options, including high-security options that are not accessible with the installer code if it is different from the dealer code. Changing the dealer code to differ from the installer code will prevent the installer from viewing certain fields. 1. Change the dealer code. 2. Enter program mode with the installer code. 3. Installer should no longer be able to see the following:
Code length, Downloader code, Phone lock, Phone #1, Phone #2, Phone 1 report mode, Phone 2 report mode, HW1 function. You can use the installer code to program most installer options, except for high-
security dealer options. Master arm/disarm code. Master code able to enter user programming and bypass sensors. Regular arm/disarm code. Duress code Blank Use in place of master or user code to cause a silent alarm. Code length Four digits Code can be three to six digits long. Chapter 4 Programming 41 Security Table 13. Security Function Default Description Account number 00000 Downloader code a 12345 Phone lock Off Lets you program up to a 10-character alphanumeric account number or delete an existing account number by pressing DISARM. You can enter numerical digits sequentially. To enter letters (A to F only), use the scroll buttons to select A to F then press Enter. To select next digit, press another number key. When finished press Enter. The CID format only supports account numbers with letters B through F, or numbers 0 through 9 (or a combination of those letters and numbers). Lets you set a unique five-digit code that is required for initiating Enterprise Downloader sessions. The code must be five digits long and can range from 00000 to 99999. The downloader code must match the downloader access code in the Enterprise account to perform Enterprise sessions. Prevents resetting of phone/reporting related options when a memory clear is performed (on) or resets these options to their default values when a memory clear is performed (off). The following are not reset when on:
Autoarm On Account number Dealer code Code length Call wait cancel Phone numbers 1 and 2 Phone report modes 1 to 4 Phone lock Downloader phone number Downloader code Determines how long the system protests (announces open/failed sensors) when attempting to arm with open/failed sensors, before bypassing these sensors and automatically arming the rest of the system. Note: The panel protests an arming attempt when it has not received a restore (close) signal from sensors learned into restore-specific sensors groups. Sensors learned into group 26 (fire) cannot be bypassed. When this option is on, the panel announces all open/failed sensors repeatedly for 4 minutes, then automatically bypasses the open sensors and arms the rest of the system. If a sensor is opened during the exit delay and then left open, the panel will go into alarm after the exit delay has expired. This option must be on for Unvacated premises and Exit extension to work correctly. When this option is off, the panel displays all open/failed sensors once, then automatically bypasses the open sensors and arms the rest of the system after the exit delay has expired. If other sensors are opened during the exit delay, they will also be bypassed if left open. Note: If group 13 (Instant Perimeter) sensors are opened during the exit delay, the panel goes into immediate alarm. 42 Simon XT Installation Manual Table 13. Security (continued) Function Default Description Exit extend On Secure arming Off No arm on low battery Quick exit Off Off Downloader enable a Sup protest a On Off a. Not investigated for use by UL. Determines whether the panel restarts the exit delay time if the user enters the armed premises during the initial exit delay period (on), or not (off). Turning on this feature allows users to reenter during the exit delay period, without disarming and then rearming the system. Turning off this feature requires the user to disarm and rearm the system. Note: Autoarm must be on for this option to work. Determines whether an access code is required when arming the system (on) or not
(off). This option does not affect keyfob arm/disarm operation. Determines whether the system protests arming if a low CPU battery condition exists
(on) or not (off). Determines whether pressing DISARM when the system is armed activates the exit delay time to allow exit and reentry without disarming the system (on) or not (off). This feature is useful if the user wants to step outside briefly and return, such as to get the paper. If the system is armed and the user presses DISARM, the panel announces Exit time is ON and sounds exit delay beeps. This allows a designated entry/exit door to be open for up to 2 minutes without causing alarm. When the door is closed, the beeps stop and the door is armed again. Note: For UL listed systems, Quick Exit must be Off. Enables programming of system options with downloader software. Determines whether the panel protests arming if it has not received a supervisory signal from any sensor 15 minutes before arming (on) or not (off). Note: This feature must be turned off for US installations. Chapter 4 Programming 43 Phone numbers Table 14. Phone numbers Function Phone # 1 Phone # 2 Phone # 3 Phone # 4 Default Description Blank Blank Blank Blank Lets you program up to a 26-digit central monitoring station receiver/voice event notification phone number for monitored systems. Phone digits can be 0-9, *, #, or a pause (P). To delete the phone number, press DISARM while editing a phone digit. To add a pause to the phone number press BYPASS. Pressing Enter is required if you enter fewer than 26 digits. Downloader # a Blank Lets you program up to a 26-digit phone number for the Enterprise Downloader. a. Not investigated for use by UL. Phone options Table 15. Phone options Function Default Description Man phone test On FTC DTMF dial On On 300 bps enabled On Determines whether the user can perform a manual communication test to verify communication to a central station/voice dial (on), or not (off). If you have all 4 phone #
programmed it should send a test report to all 4 before showing that test is okay. Determines whether the panel and interior sirens sound trouble beeps if it is unable to successfully send a report to a central station (on) or not (off). Determines whether the panel uses DTMF (on) or pulse (off) for dialing programmed phone numbers. Determines whether the baud rate used by the panel for central station communication is 300 bps (on) or 110 bps (off). 44 Simon XT Installation Manual Table 15. Phone options (continued) Function Default Description Ring hang ring a 1 Determines when the panel answers a remote phone access or Enterprise call. Depending on whether an answering machine exists at the panel location, offsite access to the panel can be done with a series of phone calls or just one. For offsite access where an answering machine does not exist, the user or Enterprise operator simply calls the panel location once and listens for 10 rings. The panel should answer after the tenth ring. For offsite access where an answering machine exists, the user or Enterprise operator must perform the following steps:
Call the panel location. Let the phone ring once, then hang up. Wait at least 10 seconds but not more than 40, then call the panel location again. The panel should answer on the first ring. Ring/hang/ring setting number and sequence of rings after which the panel answers:
Ring/hang/ring or ten rings 1 Ring/hang/ring/hang/ring or ten rings 2 Ring/hang/ring/hang/ring/hang/ring or ten rings 3 Ten rings 4 Ring/hang/ring 5 Ring/hang/ring/hang/ring 6 7 Ring/hang/ring/hang/ring/hang/ring Off Disabledno remote (offsite) access Dial delay 30 seconds Call wait code Off a. Not investigated for use by UL. Determines whether the panel delays dialing programmed phone numbers before sending reports (on). If Opening (Disarming) Reports is on, the panel does not delay dialing if the system is disarmed before the delay time expires. The panel dials immediately for both the alarm and opening report. Note: Regardless of this option setting, the panel always dials immediately for fire alarms, AC power failure and low battery reports. The combined dialer delay and entry delay cannot exceed 60 seconds for a UL Listed installation. The call waiting code is dialed by the panel before a phone number to disable call waiting. Verify that the end-user has call waiting with his phone service provider before changing this option from its default. CAUTION: Changing this option from its default without call waiting will prohibit the panel from calling the central station. The call waiting code is programmed the same way as a phone number. Chapter 4 Programming 45 Sensors These instructions tell how to add (learn) sensors, touchpads, and other system devices into panel memory. The panel recognizes a sensor when you press a sensor program button, press and release a tamper switch, press a sensor test button, or put a sensor into alarm. Table 16 describes the programming method for each device. Note: If you are installing a sensor on a gun case, jewelry box, or a similar case, and the sensor is active in level one, you must subdisarm to avoid putting the panel into alarm when the sensor and the magnet are separated. Table 16. Device programming Device To program Door/window sensor Press the button on the top of the sensor (cover removed) or trip the tamper. Motion sensor Smoke detector Press the button on the back of the sensor (mounting plate removed) or trip the tamper. Trip the tamper, press the test button, remove the detector from its base, or put the smoke detector in alarm. Hardwired sensor Separate the sensor from its magnet. CO alarm Plug in the module wait 5 to 7 seconds press and hold the test button for nine beeps Freeze and water sensor Trip the tamper or press and hold the button on the top of the sensor (cover removed) until the control panel confirms programming. If you do not hold the button down long enough, the system will report the sensor as open. Personal help button Press the help button until the light blinks. Remote handheld touchpad Press the emergency buttons. Keyfob ELM keyfob Press the lock and unlock buttons at the same time. Do the following:
1. 2. 3. Press the unlock button twice and hold it the third time. The light button flashes three times. Press the unlock button once and hold it the second time. The light button flashes twice. Press and hold the unlock button. The light button flashes once. Hold the button until the flashing stops. When learning sensors, the panel uses an ascending number sequence starting with 1. You can override this by entering the desired sensor number using the number keys. Learning sensors To learn a sensor:
1. Press the scroll buttons until the panel displays System programming. 2. Press Enter. The system prompts for an access code. 3. Enter the dealer or installer code and press Enter. The panel displays Access codes. 4. Press the scroll buttons until the panel displays Sensors. 5. Press Enter. The panel displays Learn sensor. 46 Simon XT Installation Manual 6. Press Enter. The panel displays Trip sensor ##, with the number signs flashing. Note: If you wish to use a sensor number other than the next one available, use the number keys to enter a two-digit sensor number immediately. 7. Press the sensor program button or release the sensor tamper switch. The panel displays Sn ## Grp 10
<Front Door>, with the Grp 10 flashing. Use the number or scroll buttons if you want to enter a new group number; press Enter to accept the group number displayed. 8. The sensor text is now flashing. Use the scroll buttons to scroll through the text list or enter the three-
digit shortcut. (See Table 38 on page 72 and Table 39 on page 73 for these three-digit codes). Press Enter to accept the first text segment. You may enter more text or press Enter again to finish adding the sensor. 9. The panel displays Trip sensor ## (with the next available sensor number). Press STATUS repeatedly to exit. Deleting sensors To delete a sensor:
1. Press the scroll buttons until the panel displays System programming. 2. Press Enter. The panel displays Enter code. 3. Enter your access code and press Enter. The panel displays Access codes. 4. Press the scroll buttons until the panel displays Sensors. 5. Press Enter. The panel displays Learn sensor. 6. Press the scroll buttons until the panel displays Delete sensor. 7. Press Enter. The panel displays Sn ## Grp ## <Text>. 8. Press the scroll buttons until the panel displays the sensor you want to delete. 9. Press Enter. The panel displays Deleted, then shows Delete sensor. 10. Press STATUS twice to exit. Editing sensors You can use this feature to change the group or name of a sensor that is already in panel memory. The procedure is very similar to the procedure used to program sensor information after a sensor is learned in. Pressing DISARM while editing sensor text deletes all text for that sensor. Table 17. Sensors Function Default Description Learn sensors Delete sensors Edit sensors Adds (learns) sensors to panel memory. Deletes sensors from panel memory. Edits sensor information in panel memory. Chapter 4 Programming 47 Reporting Table 18 and Table 19 on page 49 provide report option details. Table 18. Reporting options Function Default Description Opening reports Off Closing reports Off Force armed Off AC power failure Off Determines whether the panel sends opening reports to a central station whenever the system is disarmed (on), or not (off). User number will be reported as zone number. Keyfobs learned into zone 1 to 40 will report as zone they are learned into. Dealer code = 44 Installer code = 45 Master code = 46 User code 1 = 47 User code 2 = 48 User code 3 = 49 User code 4 = 50 User code 5 = 51 User code 6 = 52 User code 7 = 53 User code 8 = 54 Duress code = 55 Determines whether the panel sends closing reports to a central station whenever the system is armed (on), or not (off). User number will be reported as zone number. Keyfobs learned into zones 1 through 40 will report as the zone they are learned into. Dealer code = 44 Installer code = 45 Master code = 46 User code 1 = 47 User code 2 = 48 User code 3 = 49 User code 4 = 50 User code 5 = 51 User code 6 = 52 User code 7 = 53 User code 8 = 54 Duress code = 55 Determines whether the panel sends a force armed report to a central station if the user bypasses protesting sensors (indirect bypass) when arming the system (on) or not (off). Determines whether or not the panel sends AC power failure reports to a central station after the programmed time expires. The time can be set from 005-254 minutes. When the panel is without AC power for 30 seconds, the panel LEDs turn off. When the panel is without AC power for the programmed time, an AC power failure is reported. The panel reports an AC power restoral when AC power returns to the panel. 48 Simon XT Installation Manual Table 18. Reporting options (continued) Function Default Description Low CPU battery On Determines whether the panel sends a low CPU battery report to the central station when the panel backup battery voltage drops Sen alarm restore 24-hour sensor tamper Supervisory tamper a Off Off Off No usage a Off Determines whether the panel reports sensor alarm restorals (on) or not (off). Setting when restorals are reported:
Immediately after sensor is closed or restored after dial delay. 1. 2. After siren timeout expires if sensor is restored. 3. When system is disarmed if sensor is restored. Determines whether the system (armed or disarmed) goes into and reports an alarm anytime a sensor tamper switch is tripped (on), or only when the system is armed and a tamper switch of an armed sensor is tripped (off). Determines whether the panel sends supervisory reports to a central station as a tamper (on) or a supervisory (off). This option is typically used only in Europe where a supervisory condition is required to report as a tamper. Determines whether the panel sends a No Usage report to the central station if the user has not operated the system before the programmed time expires (on) or not (off). The timer starts each time the system is disarmed. This is a customer service feature that alerts the central station if a customer is not using their security system. The service provider can then contact the customer to find out why the system is not being used, and help correct any problems for the customer. Swinger shutdown On Determines whether the panel prevents the same sensor from activating an alarm more than once in a single arming period (on) or not (off). Program report Off Fire verify Off a. Not investigated for use by UL. Note: Swinger Shutdown does not affect smoke and fire sensors. Determines whether the panel sends a report to the central station anytime the programming mode is entered/exited (on) or not at all (off). The panel sends a report whenever the dealer (Utility 1) or installer (Utility 2) code is used to enter programming mode and another report is sent when the programming session ends. If this option is off, the panel immediately reports to the central station when a smoke detector goes into alarm. With this option on, if a single smode detector goes into alarm the panel will not report for 60 seconds unless another smoke detector goes into alarm. If the first smoke detector is cleared of alarm with the first 60 seconds, no report will be sent to the central station unless it or a second smoke detector goes into alarm within the panel siren timeout period (5 minutes). Chapter 4 Programming 49 Table 19. Communication modes Function Default Description Phone 1 report mode Off Phone 2 report mode Phone 3 report mode Phone 4 report mode All SIA All CID Alarm SIA Alarm CID Nonalarm SIA Nonalarm CID Backup SIA (phone failure backup) Backup CID (phone failure backup) Voice dialer Off Note: UL has only verified reporting compatibility with the CS5000 Digital Alarm Communicator Receiver. For UL listed systems, Phone 1 Report Mode must be set to All SIA or All CID. Alarms include: Fire, Intrusion, Emergency, Silent, and Alarm Cancels. Nonalarms include: Latchkey, No Activity, Openings, Closings, Fail to Open, Fail to Close, Force Armed, AC Power Failure, CPU Low Battery, and Trouble Restorals. Timers Table 20 provides timer option details. Table 20. Timers Function Default Description Latchkey time a Off Entry delay 030 seconds Exit delay 060 seconds Determines whether the panel reports a latchkey alarm if the system is not disarmed at a preset time between midnight and 11:59 P.M. (on). If the latchkey feature is disabled
(off), the panel will not report a latchkey alarm. The system clock must be set for the latchkey feature to work. Determines how much time the user has to disarm the system after entering the armed premises through a designated delay door, before an alarm occurs. Beeps sound during the entire delay time to remind the user to disarm the system. When turned on, the Entry Delay can be set from 030 to 240 seconds. Determines how much time the user has to leave the premises through a designated delay door after arming the system. Beeps sound after arming the system to remind the user to leave the armed premises. If a delay door is opened after the Exit Delay expires, the Entry Delay begins. If the user arms the system with No Delay and opens a delay door after the Exit Delay expires, an alarm occurs. When turned on, the combined dial and entry delay cannot exceed 60 seconds for a UL Listed installation. 50 Simon XT Installation Manual Table 20. Timers (continued) Function Default Description No activity tm a Off Autophone test b Off Supervisory time 12:00am Alarm cancel 006 RF time-out 12 hours Fail-to-open time a Fail-to-close time a Off Off Siren time-out 005 minutes Arm LED shutdown Unvacated premises Off On Determines whether the panel sends a No Activity report to a central station when the programmed time period elapses (on), or if the feature is disabled (off). No activity means control panel, remote handheld, and key-chain touchpad buttons have not been pressed and sensors have not been tripped within a specified period of time (except sensors in group 25). The timeout can be set from 02 to 24 hours. Determines whether the panel automatically performs a periodic phone test (on) or not
(off). The test interval can be from 001 to 254 days. The time of day the panel performs the test is determined by Supervisory Time, which must be turned on for this feature to work. Determines when the panel reports supervisory conditions (sensor failures) and automatic phone tests to the central station. The panel clock must be set to the correct time for this option and the automatic phone test to work correctly. Sets the time frame that determines whether the panel reports an alarm cancel message to the central station. If the system is disarmed from an alarm state within the programmed time, the panel sends an alarm cancel message to the central station. An alarm cancel message is not reported if the system is disarmed after the programmed time expires. The time can be set from 006 to 255 minutes. When set to 255, the panel always reports alarm cancel messages. Turning off this option disables alarm cancel reporting. Determines the time period the panel must receive at least one supervisory signal from learned sensors before identifying a sensor failure and sounding trouble beeps. Any sensor failure is reported immediately and again at the supervisory time (Supervisory Time). The timeout can be set from 02-36 hours. Entries must be two digits. Determines whether the panel sends a Fail to open report to a central station if the system has not been disarmed by the programmed time (on), or not (off). System time must be set correctly for this feature to work. Determines whether the panel sends a Fail to Close report to a central station if the system has not been armed by the programmed time (on), or not (off). System time must be set correctly for this feature to work. Determines how long sirens sound alarms if no one is present to disarm the system. The time can be set from 002 to 254 minutes. When this feature is turned off, sirens sound alarms until the alarm is canceled (system is disarmed). Determines whether the panel LEDs (buttons) turn off 30 seconds after the last button press (on) or remain on for the entire arming period (off). Determines whether the system automatically arms down to level 2 (doors and windows) if the user arms the system to level 4 (doors, windows, and motion sensors) without leaving the premises (on), or remains at the armed level chosen by the user (off). This feature does not work from a keyfob. Autobypass must be on for this feature to work. Chapter 4 Programming 51 Table 20. Timers (continued) Function Default Description Smoke supervision Off Determines how often the panel must receive supervisory signals from the smoke sensors. If this option is on, the panel must receive at least one supervisory signal from smoke sensors every four hours or it will identify a sensor failure and sound trouble beeps. If this option is off, the time for receiving supervisory signals is determined by RF Timeout. a. b. Not investigated for use by UL. For UL installations, auto phone test must be turned on and set to 24 hours (1 day). Touchpad options Table 21 provides touchpad option details. Note: These options have not been investigated by UL.. Table 21. Touchpad options Function Default Description Keyfob no delay Off Panic alarms On Remote TP arm Off Determines whether a keyfob arms the system with no delay (on) or not (off). When this feature is on, you must disarm the system before entering the premises, since it is disabling the entry delay. If Remote touchpad arming is on, keyfobs cannot disarm the system and will cause an alarm upon entering. Determines whether the panel panic buttons (police, auxiliary, and fire) activate alarms when pressed (on) or not (off) Determines whether keyfobs and remote touchpads can disarm the system only during exit and entry delays (on) or arm and disarm the system anytime (off). If this option and Keyfob no delay are on, users cannot enter and/or disarm using remote touchpads without causing an alarm. System options Table 22 provides system option details. Table 22. System options Function Default Description RF jam detect Off Demo mode a Off Determines whether the panel checks for and reports RF interference/jam to the central station (on) or not (off). If this option is on and the panel receives a constant 319.5 MHz signal, the panel reports the condition to the central station. If this option is off, the panel does not detect an RF jam. Determines whether the panel operates as a demonstration model (on) or a standard panel (off). Turning on this feature disables low battery supervision and allows the microphone to remain on continuously during an AVM session. With option on panel is not testing battery supervision. 52 Simon XT Installation Manual Table 22. System options (continued) Function Default Description HW 1 function 1 The setting for this option determines how the HW1 I/O output will function. Off =
1 =
2 =
3 =
4 =
5 =
No output. Interior siren output. Output activated when armed. Output activated when disarmed. Fail to communicate output; activates when fail to communicate condition occurs (Fail to communicate must be on) two. Alarm output activated when panel is in alarm 24-hour clock Off Determines whether the panel uses a 24-hour clock (on) or 12-hour clock (off). a. Not investigated for use by UL. Siren options Table 23 provides siren option details. Table 23. Siren options Function Default Description Piezo beeps Panel voice Panel piezo alarm On On On Trouble beeps On This option determines whether the panel piezo produces beeps based on system activity (on) or is silent (off). When On, arming level changes will be spoken. Determines whether the panel piezo emits alarm sounds (on) or not (off). Determines whether the panel, X10, and hardwired interior sirens sound six beeps every minute when a trouble condition occurs (on) or not (off). The following conditions cause trouble beeps:
AC power failure (when AC power failure report is on) low CPU battery Sensor failure (supervisory) Sensor trouble (low battery, tamper, etc.) Fail to communicate Restoration of power No Activity timer has timed out. Trouble beeps continue for 5 minutes and if the panel does not see activity, trouble beeps stop and the panel reports the no activity to the central station. Trouble beeps can be silenced by arming or disarming the system or by pressing the STATUS button. Trouble beeps resume 4 hours later if the trouble condition is not cleared. Voice chime Off Determines whether the panel announces the sensor name. 1 = Sensor name 2 = Loud ding-dong bell 3 = Soft ding-dong bell Off = No sound Chapter 4 Programming 53 Table 23. Siren options (continued) Function Default Description Status beeps vol. 7 HW siren sup. Off Speaker volume 8 Silent police panic Panel tamper alarm Alarm report verify Off Off Off Determines the panel piezo volume level for status sounds such as arming, trouble, and status beeps. Volume range is 1 (lowest) to 10 (highest). Determines whether the panel monitors hardwired sirens for open conditions (on) or not
(off). If this option is turned on, sirens connected to the panel terminals require an EOL resistor in the wire circuit. (See on page 17 for siren wiring.) If this option is turned off, EOL resistors are not required whether sirens are connected or not. Sets the volume of voice messages from the panel speaker. Volume range is 1 (lowest) to 8 (highest). Determines whether pressing the panel police panic button causes an audible (off) or silent (on) alarm. Determines whether the panel activates a tamper alarm anytime the cover is opened
(On) or only when the system is armed (Off). This option determines whether the panel verifies successful alarm reports to the central station by displaying Phone comm is OK (On), or not (Off). Piezo beep options Table 24 provides piezo beep option details Table 24. Panel piezo beeps Activity Piezo beep response Arm doors and windows Exit delaytwo beeps sound every five seconds and two times per second during the last ten seconds. Silent exittwo beeps sound at the beginning of the exit delay and two more sound just before the exit delay expires. Entry delaytwo beeps sound every five seconds and two times per second during the last ten seconds. Arm motion sensors Exit delay three beeps sound every five seconds and three times per second during the last ten seconds. Silent exit three beeps sound at the beginning of the exit delay and three more sound just before the exit delay expires. Entry delay three beeps sound every five seconds and three times per second during the last ten seconds. Arm doors/
windows and motion sensors Exit delay four beeps sound every five seconds and four times per second during the last ten seconds. Silent exit four beeps sound at the beginning of the exit delay and four more sound just before the exit delay expires. Entry delay four beeps sound every five seconds and four times per second during the last ten seconds. Disarm Chime One beep Two beeps (when programmed) Special chime Three beeps (when programmed) Trouble beeps Six beeps every minute. Press STATUS to stop beeps for four hours. No activity a Twenty beeps every minute for five minutes (when programmed) a. Not investigated for use by UL. 54 Simon XT Installation Manual Audio verification options Table 25 provides audio verification option details. Note: These options have not been investigated for use by UL. Table 25. Audio verification Function Default Description Audio mode Off Fire shutdown Off Panic talk Off Vox Rx gain 06 Vox mic gain 24 Vox mic gain rng 64 Manual mic gain 64 1 = Instant. Panel stays online with central station for an instant audio session. 2 = Callback. Panel hangs up and waits for a callback from the central station operator before starting an audio session. Off = No audio verification. Determines whether system Fire sirens are silenced during a two-way audio session (on) or not (off). Beeps sound every 10 seconds while sirens are silenced. Determines whether the central station operator can talk to the user during a silent alarm (off) or just listen in on the premises (on). Silent alarms occur when sensors learned into groups 02 or 03 are tripped, when the duress code is entered, or when the panel Police button is pressed and the Silent Panel Police Panic option is turned on. Determines the receiver gain level during two-way audio sessions. If the VOX is switching the speaker on when the central station operator is not talking, lower both this setting and the VOX mic gain setting. If the VOX is not switching the speaker on when the central station operator is talking, raise this setting and lower VOX Mic Gain setting. Changing this setting does not affect speaker volume. Sets the mic gain (sensitivity) that triggers the voice-activated switching (VOX). Room size, acoustics, and furnishings where the panel or Interrogator 200 are located will influence the setting. Gain range is 01 (lowest) to 64 (highest). Sets the gain range for voice-activated switching (Vox). Range is 01 (lowest) to 64
(highest). For best results, this option should be set equal to or greater than Vox mic gain. Note: This option works in conjunction with Vox mic gain. It is important to follow the setting recommendations as described to achieve acceptable operation. Determines the gain level (sensitivity) during two-way audio sessions when audio mode is set to 0 or 1 (speak). Room size, acoustics, and furnishings where the panel is located will influence the setting. Gain range is 01 (lowest) to 64 (highest). Light control (optional) If your system uses optional X10 modules, you can program them to control lights. Note: This feature has not been investigated for use by UL. X10 module operation Use the following procedure to program X10 module operations into panel memory. To program the housecode:
1. Press the scroll buttons until the panel displays System programming. Chapter 4 Programming 55 2. Press Enter. The panel displays Enter code. 3. Enter your access code and press Enter. The panel displays Access codes. 4. Press the scroll buttons until the panel displays Light control. 5. Press Enter. The panel displays Set entry lights. 6. Press the scroll buttons until the panel displays Housecode <A-O>. 7. Press Enter. The letter flashes. 8. Press the scroll buttons until the letter you want displays. 9. Press Enter to accept the new housecode. The panel displays Housecode <new housecode>. 10. Press STATUS twice to exit program mode. To program an entry-activated light:
1. Press the scroll buttons until the panel displays System programming. 2. Press Enter. The panel displays Enter code. 3. Enter your access code and press Enter. The panel displays Access codes. 4. Press the scroll buttons until the panel displays Light control. 5. Press Enter. The panel displays Set entry lights. 6. Press Enter. The panel displays Entry light unit 1 on/off. 7. Press the scroll buttons until the unit number you want to program displays. 8. Press Enter. The panel displays Off, which will be flashing. 9. Press the scroll buttons until the panel displays On, then press Enter. 10. Press STATUS three times to exit program mode. To program a sensor-activated light:
1. Press the scroll buttons until the panel displays System programming. 2. Press Enter. The panel displays Enter code. 3. Enter your access code and press Enter. The panel displays Access codes. 4. Press the scroll buttons until the panel displays Light control. 5. Press Enter. The panel displays Set entry lights. 6. Press the scroll buttons until the panel displays Sensor light. 7. Press Enter. The panel displays Sn ## <Text> X-10 unit = on/off. 8. Press the scroll buttons until the panel displays the sensor number you want to activate. 9. Press Enter. The panel displays On/off, which will be flashing. 10. Press the scroll buttons until the panel displays On. 11. Press Enter. 12. Press STATUS three times to exit. 56 Simon XT Installation Manual Note: You can also program a keyfob button to control a light or appliance module. To program a light schedule:
1. Press the scroll buttons until the panel displays System programming. 2. Press Enter. The panel displays Enter code. 3. Enter your access code and press Enter. The panel displays Access codes. 4. Press the scroll buttons until the panel displays Light control. 5. Press Enter. The panel displays Set entry lights. 6. Press the scroll buttons until the panel displays Set entry lights. 7. Press Enter. 8. Press the scroll buttons until the panel displays Light schedules. 9. Press Enter. The panel displays Light schedule 1 <--:-- - --:-->. 10. Press the scroll buttons until the panel displays the unit number you want to program. 11. Press Enter. The HH of the start time will flash. 12. Press the scroll buttons to set the hours. 13. Press Enter. The MM of the start time will flash. 14. Press the scroll buttons to set the minutes. 15. Press Enter. The AM/PM of the start time will flash. 16. Press the scroll buttons to set the AM/PM setting. 17. Press Enter. The end time starts to flash. 18. Follow the same instructions to set the hour, minute, and AM/PM settings for the end time. 19. Press STATUS repeatedly to exit. Lock interval Note: This feature has not been investigated for use by UL. Sets the start and stop times that determine when the panel prevents the sensor-activated lights feature from turning on sensor-activated lights. Note: System time must be set correctly for this feature to work. When a time value is set (on) and the sensor-activated lights feature is on, the panel prevents sensor-activated lights from turning on between the programmed start time (this option) and the programmed stop time. Note: Both sensor-activated light lockout start time and sensor-activated light lockout stop time must have a time programmed for this feature to work correctly. Chapter 4 Programming 57 When both sensor-activated light lockout start time and sensor-activated light lockout stop time are turned off and the sensor-activated lights feature is on, sensor-activated lights turn on at all times. Table 26. Light control Function Set entry lights:
Default Description Entry light unit, 1 through 8 Off This menu allows the user to set X-10 lights with unit numbers from 1 to 8 as entry lights (On). Sensor light # 01 to 40 Light schedules Light schedule, 1 through 8 Housecode Lock interval
(Light) lock interval Off A Blank In this menu, each enrolled sensor can be associated with an X-10 light with unit number from 1 to 8 (or Off for no association). In this menu, a light schedule can be programmed for each X-10 module with unit number from 1 to 8. This option sets the daily lockout time during which sensor trips do not activate associated X-10 lights System tests Table 27. System tests Function System tests Comm test Sensor test System download a a. Not investigated for use by UL. Default Description The communication test is used to check the phone communication between the panel and the central station or voice report destination. The sensor test is used to check proper sensor operation. This feature initiates a phone call from the panel to the Enterprise Downloader. 58 Simon XT Installation Manual Resetting memory to the factory defaults To reset the panel to its factory defaults, do the following:
1. Open the panel cover. 2. Unplug the transformer and disconnect the battery. 3. Press and hold the four arming/status buttons (DOORS+WINDOWS, MOTIONS, DISARM, and STATUS) on the front of the panel and the tamper switch on the inside of the panel (see Figure 5 on page 24). 4. Restore power to the panel with the battery while holding the four buttons and tamper switch. 5. Release the buttons. 6. Plug in the transformer to the outlet. Note: The procedure to reset memory to factory defaults is meant to be difficult. It is also possible to restore power to the panel by plugging in the transformer first, which allows the panel to be closed so that the tamper switch does not need to be pressed. If you do this, be sure to reconnect the battery. Program the panel in this order:
1. Set the panel clock. 2. Add (learn) sensors. 3. Set the housecode and light and appliance controls (entry/exit activated lights, sensor-activated lights, time-activated lights). 4. Change options as needed. Note: If phone lock is on, phone numbers 1 and 2, downloader phone number, account number, phone lock, downloader code, phone report mode 1, phone report modes 1 to 4, access code length, and call waiting and dealer code will not reset to their defaults. Chapter 5 Testing This section describes how to perform various test procedures. You should test the system after installing, after servicing, and after adding or removing devices from the system. In this chapter:
Control panel. 60 Sensor testing. 61 If a sensor fails the sensor test . 62 Phone communication. 63 Offsite phone operation. 63 Central station communication . 64 Two-way voice operation. 65 Voice event notification. 65 X10 operation . 66 Manual lamp module control . 66 X10 siren and lamp module functions. 66 60 Simon XT Installation Manual Control panel Test the panel by pressing the buttons as described in Table 28. Table 29 provides a list of the arming levels. Note: An access code is required when arming if the Secure arming option is on.. Table 28. Control panel test sequence Correct result The button will blink when No entry delay is on. The button blinks when latchkey is on. The panel will disarm doors, windows, and motion sensors. Button DOORS +
WINDOWS MOTIONS DISARM STATUS POLICE FIRE EMERGENCY Function tested The panel arms door and window sensors. The panel will arm motion sensors. The panel will prompt you to enter an access code. Test Press DOORS + WINDOWS a second time to eliminate the programmed entry delay. Press MOTIONS a second time to turn latchkey on. Enter the appropriate code. Press STATUS button for panel to display and speak the system status. Press and hold or press button twice quickly to activate a nonmedical, police, or fire emergency alarm. Press and hold or press button twice quickly to activate a nonmedical, police, or fire emergency alarm. Press and hold or press button twice quickly to activate a nonmedical, police, or fire emergency alarm. Note: Forty key presses for invalid codes (ten invalid 4-digit codes, for example) will cause a system access alarm. The alarm locks all touchpads, except keyfobs, for 90 seconds. Table 29. Arming levels Arming level 0 1 2 3 4 Description Subdisarms (master access and duress codes only), and bypasses 24-hour intrusion sensors (master access code only). Fire sensors
(group 26) cannot be subdisarmed. Disarm the system Arm doors and windows Arm motion sensors Arm doors, windows, and motion sensors Indication One beep indicates the system is subdisarmed. The panel displays and speaks Subdisarmed. The DISARM button blinks. One beep indicates the system is disarmed. The panel displays and speaks Disarmed. The DISARM button lights. Two beeps verify that door/window sensors are armed. The panel displays Doors + Windows and speaks Doors and windows on. The DOORS+WINDOWS button lights. Three beeps verify that motion sensors are armed. The panel displays Motions and speaks Motions On. The MOTIONS button lights. Four beeps verify that door/window and motion sensors are armed. The panel displays Doors + Windows & Motions and speaks Doors and windows on, Motions on. The DOORS+WINDOWS and MOTIONS buttons light. Chapter 5 Testing 61 Sensor testing Test the sensors after all programming is completed and whenever a sensor-related problem occurs. Note: While the sensor test is a valuable installation and service tool, it only tests sensor operation for the current conditions. You should perform a sensor test after any change in environment, equipment, or programming. Notify the central station you will be performing a test prior to starting the test. To test the sensors, do the following:
1. Place all sensors in their secured (no alarm) state. 2. Go to the Sensor Test option under the System tests menu, then press Enter. The panel will prompt you to trip each sensor one at a time. You may follow the panel prompting or test the sensors in any order. Use Table 30 to trip sensors. Table 30. Sensor tripping instructions Sensor Door/window Freeze Water Carbon monoxide alarm Glassbreak Motion sensor Rate-of-rise heat detector Shock Smoke Personal help button Keyfob Remote handheld touchpad Do this Open the secured door or window. Remove the sensor cover. Apply ice in a plastic bag to the sensor (for 10 to 15 minutes). Do not allow the sensor to get wet. Press a wet rag or wet finger over both of the round, gold-plated terminals on the underside of the sensor. Unplug the CO Alarm. Plug it back in, wait 5 seconds, then press the TEST/
RESET button until the unit beeps 8 times. Tap the glass 3 to 4 in. (8 to 10 cm) from the sensor. Avoid the motion sensor field of view for five minutes, then enter its view. Rub your hands together until warm, then place one hand on the detector for 30 seconds. Tap the glass twice, away from the sensor. Wait at least 30 seconds before testing again. Press and hold the test button until the system sounds transmission beeps. Press and hold the appropriate help button until the light blinks and the panel sounds for at least seven beeps. Press and hold LOCK and UNLOCK simultaneously for three seconds. Press and hold the two EMERGENCY buttons simultaneously for three seconds. 3. Interior sirens sound transmission beeps, and the display identifies the tripped sensor and the number of RF packets received. Each beep represents one RF packet. Count the number of beeps and refer to Table 31 for minimum requirements. After the beeps, the panel displays Sn # Packets=XX Name
(where XX equals the number of RF packets and Name equals the sensor name). The system will continue to prompt for sensors that have not yet been tested. When all sensors have been tested, the panel will display Sn test complete Press Status. Note: If a sensor does not meet the minimum transmission beep requirements, see If a sensor fails the sensor test on page 62. 62 Simon XT Installation Manual Table 31. Minimum beeps Type of sensor Wireless intrusion sensors Wireless smoke and heat sensors Wireless environmental/panic buttons Hardwired loops Emergency buttons (remote handheld touchpads only) Number of beeps 78 78 78 1 7-8 4. Press STATUS. The panel displays Sensor Test Ok. 5. If you press STATUS and the panel has not heard from all sensors, the panel will display Sn test fail or aborted. If a sensor fails the sensor test If sirens do not beep when a sensor is tripped, use an RF Sniffer (60-401) test tool to verify that the sensor is transmitting. Constant beeps from the RF Sniffer indicate a runaway (faulty) sensor. Replace the sensor. If possible, locate sensors within 100 feet (30 meters) of the panel. While a sensor may have a range of 500 feet
(152 meters) or more out in the open, the environment at the installation site can have a significant effect on transmitter range. A change in sensor location may help overcome adverse wireless conditions and can be accomplished by the following:
Reposition the sensor Relocate the sensor If necessary, replace the sensor To reposition a sensor:
1. Rotate the sensor and test for improved sensor communication at 90 and 180 degrees from the original position. If poor communication persists, relocate the sensor. 2. To relocate a sensor:
Increase the distance from the original position and retest until an acceptable location is found. 1. Test the sensor a few inches from the original position. 2. 3. Mount the sensor in the new location. 4. If no location is acceptable, replace the sensor. To replace a sensor:
1. Test a known good sensor at the same location. 2. 3. If the transmission beeps remain below the minimum level, avoid mounting a sensor at that location. If the known-good sensor functions, contact GE Security for repair or replacement of the problem sensor. Chapter 5 Testing 63 Phone communication Perform a communication test to check the phone communication between the panel and the central station. To perform a communication test:
1. Go to the Comm test option under the System tests menu. 2. Press Enter. The panel confirms that a communication test has begun. When the communication test is complete, the panel will display Comm test is OK within 3 minutes. If the test is unsuccessful, the STATUS button will light and the panel will display Comm failure within 10 minutes. If the panel displays Comm failure:
1. Check that the panel is connected to the phone jack. 2. Check the phone number programmed into the panel. 3. Perform the communication test again. 4. If the communication test fails again, check the phone connection wiring. Offsite phone operation Test the system from a remote phone by calling the panel and using the commands in Table 32. Note: This feature has not been investigated by UL. Table 32. Phone commands System function Disarm Arm doors/windows Arm motion sensors Arm doors/windows with no entry delay Arm motion sensors with latchkey Arm doors/windows and motion sensors Arm doors/windows with no entry delay and motion sensors with latchkey Specific light on Specific light off All lights on All lights off System status Audio verification Terminate session Phone command 1 2 3 2 2 3 3 2 3 2 2 3 3
* <unit_num>.
# <unit_num>.
* *
# #
0 5 + X (X = a command from Audio Verification Set) 9 64 Simon XT Installation Manual Central station communication After performing sensor and communication tests, check that the system is reporting alarms successfully to the central station. Table 33 provides a list of sensor/user report codes. To test communication with the central station:
1. Call the central station and tell the operator that you will be testing the system. 2. Arm the system. 3. Test each of the wireless panic buttons and trip at least one sensor of each type (fire, intrusion, etc.) to verify that the appropriate alarms are working correctly. 4. When you finish testing the system, call the central station to verify that the alarms were received. Table 33. Sensor/user report codes Arm or disarm from Panel or remote handheld touchpad Keyfob Panel aux panic Panel tamper Panel police panic Panel fire panic Dealer access code Installer access code Master code Access codes 1 to 8 Duress code Reports as user 0 1 to 40 (sensor number) 41 42 43 44 44 45 46 47 to 54 55 Chapter 5 Testing 65 Two-way voice operation For the central station operator to initiate an audio session:
Note: Panel voice announcements are silenced during AVM sessions. If the operator does not terminate the session correctly, panel announcements may not occur for up to 90 seconds after the operator hangs up. 1. After the panel has completed reporting the alarm, pick up the CS phone and press the * button to start the audio session. 2. Press 1 or 0 to speak, 2 for VOX operation, and 3 or 6 to listen. 3. Press 99 to terminate the session. Table 34. Audio verification set Phone buttons Function 0-1 2 3 or 6 7 88 99 Speak VOX operation Listen Extend session for 90 more seconds Terminates session with call back (the panel answers on the first ring if called within 5 minutes) Terminates session with no call back Voice event notification Testing this feature requires two people; one at the alarm site and the other at the location the panel is programmed to call. 1. Contact the central monitoring station (if system is monitored) to inform them you are testing the system and not to dispatch authorities. 2. At the system site, put the system into an alarm condition. 3. At the calling location, pick up the phone after it starts ringing. You should hear the panel voice announce Press star for alarm. 4. Press * and the panel voice identifies the alarm. If there is more than one alarm in progress, the user must press * for the panel voice to identify them. Note: You must terminate the call by pressing #. Otherwise, the panel may not disconnect from the phone line for up to 2 minutes. 5. After all alarms have been identified, the panel announces Press # to exit. 6. Press # to terminate the call. 66 Simon XT Installation Manual X10 operation The following sections describe how to test X10 lamp, siren, appliance, and universal module operation. Manual lamp module control Control panel: Press the asterisk button (*) and the unit number of the lamp module using the numeric buttons to test individual lamp modules 1 through 8. The panel responds with Light # on/off. Press the asterisk button (*) twice to turn on all lamp modules. Press the pound button (#) twice to turn off all lamp modules. Keyfob: Press the Light button repeatedly to turn all lights on and off. The panel responds with Lights on/off. Remote handheld touchpad: Press the Lights on button and the unit number of the lamp module using the numeric buttons to test individual lamp modules 1 through 8. The panel responds with Light
# on/off. Pressing the Lights on or Lights off button twice turns all the lights on or off. X10 siren and lamp module functions All sirens turn off when the system is disarmed or when the siren timeout expires. Siren priority is fire (highest priority), intrusion, and emergency. Table 35 identifies the light information for each of these siren types. Table 35. Alarm siren and X10 light information X10 lights X10 siren Fire Steady Steady Interior and panel Siren Temporal 3 Intrusion Flashing Steady Steady Emergency Steady Alarm beeps Fast on/off If an alarm of greater priority occurs during an alarm of lower priority, the greater priority alarm sirens sound. Fire alarms sound a temporal 3 pattern (0.5 seconds on, 0.5 seconds off for three beeps then 1.5 seconds off). Note: The X10 siren must be set to unit #9 to hear emergency alarms and status beeps. To hear emergency alarms only, set to unit #10. Chapter 6 Troubleshooting and support This chapter provides information to help you troubleshoot problems, perform simple preventive maintenance procedures, and contact technical support in case you need assistance with your GE equipment. In this chapter:
Troubleshooting . 68 Contacting us. 70 Online resources . 70 68 Simon XT Installation Manual Troubleshooting This section provides information to help you diagnose and solve various problems that may arise while configuring or using your GE product and offers technical support contacts in case you need assistance. (See Contacting us on page 70.) System status To clear STATUS (alarm memory), do the following:
From a disarmed state press STATUS, listen to the status message, then press DISARM. The panel displays and announces Siren 1 failure. Turn the Hardwired Siren Supervision option off if a hardwired siren or sensor is not connected. Check for the correct end-of-line resistor in HW1 I/O circuit. Panel displays and announces Low battery. Check that panel backup battery is connected. Check panel backup battery voltage. If less than 5.4 volts, replace battery and clear system status message. Run sensor test. The panel displays and announces RF jam. The control panel has detected RF interference. The panel displays and announces that a sensor is open. See Sensors on page 69. The panel displays Set Time and announces System time is not set. Set the system time. Control panel The panel displays and announces Invalid. This sensor is already programmed. Delete sensor if not correctly programmed. Options (programmable by the homeowner) The panel does not beep. Turn on Piezo Beeps option. Latchkey does not function. Latchkey time is not set. Set latchkey time. Latchkey is not enabled. Enable latchkey by pressing MOTIONS twice. The phone number is not programmed properly. Reprogram the phone number. System time is not set. Set system time. Chapter 6 Troubleshooting and support 69 Sensors A sensor does not work. Make sure the battery is good and installed correctly. Check for interference from metal objects. Move or rotate the sensor. Move the sensor to a new location. Door or window is closed, but the panel announces it is open. Be certain the arrow on the magnet and the guide line on the transmitter are aligned and within 1/4 inch of each other. The sensor tamper switch may be open (cover off). Motion sensors go off continuously. Be sure the sensor is mounted on a solid surface and the viewing field is free from sources of changing temperature. Motion sensor does not respond to motion. Make sure the sensor battery is good and installed correctly. Wait 2 minutes after installing a new battery to test the sensor. Adjust the sensor mounting. Dirt or dust may be causing the problem. Wipe the sensor with a clean, damp cloth. Leave the area for 3 minutes, then retest. The environment is too hot or too cold. Outdoor sensors operate between 32 and 120F (0 and 49C). X10 modules All lamp modules or siren not working. Be sure the panel transformer is plugged into an outlet that is not controlled by a switch. Check that the panel is powered using the line carrier power transformer. Housecode was programmed incorrectly. One lamp module or siren is not working. Unplug nearby equipment that may be causing interference (light dimmer switches, televisions, appliances with older motors). Check that the switch on the lamp or appliance is turned on and remains on. Make sure the lamp has a working bulb. Make sure the lamp or appliance is plugged into the Lamp/Appliance Module, the Module is plugged into the outlet and the outlet is not controlled by a switch. Make sure the House and Unit Codes are correct. Move the Module to a different outlet that is on the same phase (branch) of the household electrical circuit as the panel. Time- or sensor-activated light not working. Make sure you have programmed the light to be activated by a timer or sensor. Make sure the system clock is set. Make sure these functions have been enabled. The functions are enabled if the appropriate icon is shown on the display. 70 Simon XT Installation Manual Contacting us For help installing, operating, maintaining, and troubleshooting this product, refer to this document and any other documentation provided. If you still have questions, contact us during business hours (Monday through Friday, excluding holidays, between 5 a.m. and 5 p.m. Pacific Time). Table 36. Technical support North America Latin America T: 888 GE Security (888.437.3287). Toll-free in the US, Puerto Rico, and Canada. 503.885.5700 outside the toll-free area. F: 888.329.0332 (Tualatin tech support) 561.998.6232 (Boca Raton tech support) E: nstechsrv@ge.com (tech support) gesecurity.customerservice@ge.com (customer service) T: 305.593.4301 F: 305.593.4300 E:
InfraSec.TechnicalServicesLatinAmerica@ge.com (tcnica) InfraSecCustomerService.LatinAmerica@ge.com (cliente) Europe, Middle East, and Africa W: At www.gesecurity.eu, select Customer Support. Note: Be ready at the equipment before calling. Online resources Here are some useful links on our website www.gesecurity.com:
Online library. From the Customer Support menu, select the Resource Library link. After you register and log on, you may search through our online library for the documentation you need.1 Training. To view any available online training for GE Security products, select the Training link.
(Online training is not available for all products.) Warranty and terms information. From the Customer Support menu, select Return and Warranty Policy Statement or Terms and Conditions Policy Statement. Customer service and technical support. From the Customer Support menu, select Customer Service or Technical & Application. Select the appropriate product category for the contact information or use the dropdown menu to select a location outside the US. 1. Many GE documents are provided as PDFs (portable document format). To read these documents, you will need Adobe Reader, which can be downloaded free from Adobes website at www.adobe.com. Appendix A Specifications and tables This appendix provides a couple lists of sensor names and a quick reference chart for operating the Simon XT system with various peripheral devices. In this appendix:
Specifications. 72 Sensor names. 72 Simon XT system quick reference . 74 72 Simon XT Installation Manual Specifications Table 37. Simon XT specifications Requirement Power Description 9 VAC, 60 Hz, 3.34 A transformer Rechargeable battery: 6.0 VDC, 1.2 Ah lead-acid. The battery will last 24 hours with no AC and specified standby load of 250 mA. Maximum battery charging current is 45 mA. With loss of AC panel will continue to operate normally to a minimum of 5.1 VDC. Radio frequency 319.5 MHz Storage temperature range
-29 to140F (-34 to 60C) Operating temperature range 32 to 120F (0 to 49C) Maximum humidity 85% relative humidity, noncondensing Auxiliary power Size (L x W x D) Unregulated 5.3 to 12.3 VDC, with a maximum of 250 mA 7 x 5.75 x 2.125 in. (178 x 146 x 54 mm) Sensor names Table 38 below and Table 39 on page 73 provide alphabetical and numerically sequential lists of the sensor name segments. Table 38. Alphabetical list of sensor name segments
#
039 004 005 030 031 010 011 014 015 038 026 027 034 035 002
#
003 028 006 007 012 013 036 000 019 020 017 018 008 Master bedroom 009 Master bedroom window 037 Medicine cabinet Phrase Attic Back door Back window Basement Basement window Bedroom Bedroom window Childs room Childs room window Closet Den Den window Downstairs Downstairs window Front door
#
Phrase 041 Module 024 Office 025 Office window 023 042 021 022 029 040 001 032 033 016 Phrase Front window Garage Garage door Garage window Guest room Guest room window Hallway Keyfob (keychain) Kitchen Kitchen window Living room Living room window Patio door Phone module Porch Porch window Special chime System panic Touchpad Upstairs Upstairs window Utility room Bedroom Bedroom window Guest room Guest room window Childs room Childs room window Utility room Living room Living room window Kitchen Kitchen window Porch Porch window Patio door Table 39. Sensor name segments by index number (in scrolling order) Phrase
#
Keyfob (keychain) 000 Touchpad 001 Front door 002 Front window 003 Back door 004 Back window 005 Garage door 006 007 Garage window 008 Master bedroom 009 Master bedroom window 010 011 012 013 014 015 016 017 018 019 020 021 022 023 024 Office 025 Office window 026 027 028 029 030 031 032 033 034 035 036 037 Medicine Cabinet 038 039 040 041 Module 042 Phrase
#
A 043 B 044 C 045 D 046 E 047 F 048 G 049 H 050 I 051 J 052 K 053 054 L 055 M 056 N 057 O 058 P 059 Q 060 R S 061 T 062 063 U 064 V 065 W X 066 067 Y Z 068 0 069 1 070 071 2 3 072 4 073 074 5 6 075 7 076 8 077 078 9
/
079 080 081
!
082 @
#
083 084
$
085 %
Den Den window Garage Special chime Basement Basement window Upstairs Upstairs window Downstairs Downstairs window Hallway Closet Attic System panic Phone module 73
#
Phrase
&
086 087
*
088
(
089
) 090 091
-
092 _ 093
+
094
=
095
{
096
}
097
|
098
. 099
<
100
>
101
?
102
[space]
103 a 104 b 105 c 106 d 107 e 108 f 109 g 110 h 111 i 112 j 113 k 114 l 115 m n 116 117 o p 118 q 119 r 120 121 s t 122 u 123 124 v 125 w x 126 y 127 128 z 74 Simon XT Installation Manual Table 40. Simon XT system quick reference a Control panel Remote touchpad Keyfob Telephone Level 0: Subdisarm the system Enter the master code while the system is disarmed. Level 1: Disarm the system DISARM, <access_code>. Level 2: Arm doors and windows DOORS+WINDOWS, <access_code>
(if required). Level 3: Arm motion sensors MOTIONS, <access_code> (if required). Level 4: Arm doors, windows, motions DOORS+WINDOWS, <access_code>
(if required), MOTIONS. Activate no delay DOORS+WINDOWS, DOORS+WINDOWS. Appends No Delay to arming level text. Disarm ARM Doors &
Windows ARM Motion Sensors ARM Doors &
Windows ARM Doors &
Windows ARM Motion Sensors ARM Doors &
Windows 1 1 2 3 2 3 2 2 Activate latchkey MOTIONS, <access_code> (if required), MOTIONS. ARM Motion Sensors ARM Motion Sensors 3 3 Activate panic alarm Check system status Press Fire, Emergency, or Police twice within 3 sec. or hold it for 2 sec.
+
Hold both for 3 sec.
+
Hold both for 3 sec. STATUS SYSTEM STATUS 0 Toggle chime or special chime mode Scroll to Chime or Special Chime, Enter, toggle On/Off, Enter. Bypass a sensor BYPASS, <master_code>, scroll to the sensor, BYPASS. Time-activated lights on/off Scroll to Light Schedules, Enter, toggle On/Off, Enter. Sensor-activated lights on/off Scroll to Sensor Lights, Enter, toggle On/Off, Enter. Specific light on Press *, <unit_num>.
<unit_num>. Specific light off Press #, <unit_num>.
<unit_num>. All lights on All lights off To turn on all lights controlled by lamp modules, press * twice. The panel displays All Lights On. To turn off all lights controlled by lamp modules, press # twice. The panel displays All Lights Off.
*
<unit_num>.
#
<unit_num>.
* *
# #
a. A minus sign () between buttons means press one then the next; a plus sign (+) between buttons means press both simultaneously. 75 Index A H AC power ............................................................................................... 31 access codes............................................................................................ 40 appliance modules .............................................................................. 2, 32 audio verification options....................................................................... 54 autoarm................................................................................................... 41 handheld touchpads .............................................................................. 2, 4 hardwired contacts.................................................................................. 25 hardwired device connections ................................................................ 24 housecode ............................................................................................... 54 B back piece......................................................................................... 22, 23 backup battery ........................................................................................ 30 C call wait code.......................................................................................... 44 carbon monoxide alarms .......................................................................... 3 central station communication................................................................ 64 clock ....................................................................................................... 38 contrast ................................................................................................... 38 conventions..............................................................................................ix cross-zoning............................................................................................ 10 D dial delay ................................................................................................ 44 door/window sensors............................................................................ 2, 3 downloader code..................................................................................... 41 DSL ........................................................................................................ 27 E emergency button ................................................................................... 35 emergency planning ............................................................................... 16 Enterprise Downloader....................................................................... 2, 41 F factory defaults....................................................................................... 58 fire button ............................................................................................... 35 firmware revision ................................................................................... 38 freeze sensors ........................................................................................... 3 G GFCI....................................................................................................... 31 ground fault circuit interrupt .................................................................. 31 I indoor motion sensors .............................................................................. 3 interior siren ........................................................................................... 25 K keyfobs ................................................................................................. 2, 3 ELM keyfobs ........................................................................................ 3 L lamp modules ..................................................................................... 2, 32 latchkey .................................................................................................. 68 light control ............................................................................................ 54 line seizure.............................................................................................. 27 lock interval............................................................................................ 56 M menu navigation ..................................................................................... 36 menu structure........................................................................................ 36 motion sensor ........................................................................................... 2 O outdoor motion sensors ............................................................................ 3 P panel keys............................................................................................... 35 panel, back piece .............................................................................. 22, 23 panel, mounting...................................................................................... 23 personal help buttons................................................................................ 4 phone buttons ......................................................................................... 65 phone line wiring.................................................................................... 27 phone numbers ....................................................................................... 43 phone options ......................................................................................... 43 piezo beep options.................................................................................. 53 PIR motion sensor .................................................................................... 2 76 Simon XT Installation Manual planning.................................................................................................... 6 police button........................................................................................... 35 power transformer wiring....................................................................... 30 preface .....................................................................................................ix premises phone....................................................................................... 28 product, overview..................................................................................... 2 program mode......................................................................................... 39 programming .......................................................................................... 33 programming codes ................................................................................ 39 Q quick reference chart .............................................................................. 74 R system components .................................................................................. 3 system menu........................................................................................... 35 system options........................................................................................ 51 system tests............................................................................................. 57 T technical support .................................................................................... 70 technical support centers ........................................................................ 70 testing ..................................................................................................... 59 timers...................................................................................................... 49 touchpad options .................................................................................... 51 tripping sensors ...................................................................................... 61 troubleshooting....................................................................................... 68 two-way voice operation ........................................................................ 65 reports..................................................................................................... 47 revision ................................................................................................... 38 U S safety terms and symbols ........................................................................ix secure arming ......................................................................................... 42 sensors .................................................................................................... 45 deleting............................................................................................... 46 editing ................................................................................................ 46 groups .................................................................................................. 7 learning.............................................................................................. 45 locations............................................................................................... 6 testing................................................................................................. 61 tripping............................................................................................... 61 types ..................................................................................................... 6 siren options ........................................................................................... 52 smoke detectors .................................................................................... 2, 3 universal modules............................................................................... 2, 32 V voice event notification .......................................................................... 65 W water sensors ............................................................................................ 3 X X10 modules ...................................................................................... 3, 32 X10 operation......................................................................................... 54 X10 testing ............................................................................................. 66 77 78 Simon XT Installation Manual 466-2265 Rev. DPrinted in Mexico
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2008-03-28 | 319.5 ~ 319.5 | DSR - Part 15 Remote Control/Security Device Transceiver | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2008-03-28
|
||||
1 | Applicant's complete, legal business name |
UTC Fire & Security Americas Corporation, Inc.
|
||||
1 | FCC Registration Number (FRN) |
0005832522
|
||||
1 | Physical Address |
2955 Redhill Avenue, Suite 100
|
||||
1 |
Costa Mesa, CA
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
h******@americantcb.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
B4Z
|
||||
1 | Equipment Product Code |
910C-SIMON
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
K******** K********
|
||||
1 | Title |
Compliance Leader
|
||||
1 | Telephone Number |
949-7********
|
||||
1 | Fax Number |
949-7********
|
||||
1 |
K******@fs.utc.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DSR - Part 15 Remote Control/Security Device Transceiver | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | GE Simon XT | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
TUV SUD America - Product Service
|
||||
1 | Name |
J******** S******
|
||||
1 | Telephone Number |
651-6********
|
||||
1 | Fax Number |
651-6********
|
||||
1 |
j******@tuvam.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15.231 | 319.50000000 | 319.50000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details