Vayyar Home Dry Contact Installation Guide Vayyar.com Proprietary Data Copyright 2021 Vayyar Imaging Ltd. All rights reserved. This document is the property of Vayyar and all materials and information contained herein is the proprietary information of Vayyar and are protected by international copyright laws. The copyrights are owned by Vayyar or the original creator of the material. The materials and information contained herein are provided to you for internal information purposes only, and no portion of the materials and information herein may be copied, reproduced, distributed, transmitted, displayed, published, broadcasted or used in any way whatsoever directly or indirectly without the prior written consent of Vayyar or in any case of third party materials, without that third party's consent. This document shall be returned to Vayyar promptly upon request. The materials and information contained herein are provided "AS IS" and Vayyar does not provide any warranties of any kind, whether express or implied, including but not limited to implied warranties of merchantability, fitness for a particular purpose, and non-infringement. Vayyar Home Dry Contact Installation Guide 2 What's included:
You'll also need:
Sensor
Pencil
Wire stripper
Chassis with adhesive strips
Back cover
Front cover
Wall plugs
& screws
12/24 VDC Power Supply
3 x self-tapping screws Note: Recommended that the installation be done by a professional installer. Always abide by local regulations.
Transmitter and cables
Precision screwdriver Vayyar Home Dry Contact Installation Guide 3 In-wall installation Vayyar Home Dry Contact Installation Guide 4 1 Mark a line on the wall, measured 1.5m/5ft from the floor, where you plan to attach the sensor to the wall. Note: The 1.5m/5ft mark should align with the center of the device. 1.5m/5ft Vayyar Home Dry Contact Installation Guide 5 2 Using the front cover as a template, draw a circle with the line going through the center. 1.5m/5ft Vayyar Home Dry Contact Installation Guide 6 3 Cut out the circled area. Vayyar Home Dry Contact Installation Guide 7 4 Peel the stickers from the chassis and attach the sensor in place. Vayyar Home Dry Contact Installation Guide 8 5 Wrap the cable over the ribs and into the slot. Vayyar Home Dry Contact Installation Guide 9 6 Insert the Type-C USB Connector to the bottom of the board on the back of the Chassis. Vayyar Home Dry Contact Installation Guide 10 7 Drill holes in the wall in line with those on the chassis and insert wall plugs. Vayyar Home Dry Contact Installation Guide 11 8 Connect the dry contact alarm from the transmitter* to the Vayyar Home dry contact board.
*Transmitter not supplied by Vayyar 8 7 6 5 4 3 2 1 The transmitter cables should be connected to the bottom first (GND) and third (ALARM 1) locations on the board. Do not attach the cables at locations directly next to each other. Vayyar Home Dry Contact Installation Guide 12 9 Connect the sensor to the electrical supply*.
*Note: It is important to connect the transmitter before connecting the electrical supply. 8 7 6 5 4 3 2 1 The electrical cables should be connected to the bottom eighth (12/24V IN) and sixth (GND) locations on the board. Do not attach the cables at locations directly next to each other. Vayyar Home Dry Contact Installation Guide 13 10 Test the device, before completing wall installation:
If your device is pre-provisioned, make sure the device is powered ON and you see a white light from the LED If your device is NOT pre-provisioned, please reference the provisioning instructions provided by the Vayyar Home Customer Success team Once pairing is complete & power is confirmed, simulate the dry contact is working by pressing the power button for 2-seconds Vayyar Home Dry Contact Installation Guide 14 11 Attach the chassis to the wall with screws. Vayyar Home Dry Contact Installation Guide 15 12 Attach the front cover to the chassis and align as shown, until it snaps into place. Vayyar Home Dry Contact Installation Guide 16 Assembly is complete. Vayyar Home Dry Contact Installation Guide 17 On-wall installation Vayyar Home Dry Contact Installation Guide 18 1 Peel the stickers from the chassis and attach the sensor in place. Vayyar Home Dry Contact Installation Guide 19 2 Wrap the cable over the ribs and into the crease. Vayyar Home Dry Contact Installation Guide 20 3 Insert the USB connector. Vayyar Home Dry Contact Installation Guide 21 4 With a spirit level, mark a line 1.5m/5ft from the floor on the wall where you want the sensor. 1.5m/5ft Vayyar Home Dry Contact Installation Guide 22 5 Place the back cover on the wall so that it correctly intersects the line and is the right way up. Vayyar Home Dry Contact Installation Guide 23 6 Mark drill-hole positions on the wall, including one in the middle for the cable. Vayyar Home Dry Contact Installation Guide 24 7 Drill and insert wall plugs in line with the holes in the back cover. Vayyar Home Dry Contact Installation Guide 25 8 Attach the back cover to the wall with screws. Vayyar Home Dry Contact Installation Guide 26 9
(Optional) Connect a dry contact alarm to the sensor. 8 7 6 5 4 3 2 1 Pass the cable through the bottom-center of the device, there should be a specific opening in the back cover for the cable in this location
(see illustration). The transmitter cables should be connected to the bottom first (GND) and third
(ALARM 1) locations on the board. Do not attach the cables at locations directly next to each other. Note: Make sure the voltage reaching the system is under 5 volts. Vayyar Home Dry Contact Installation Guide 27 10 Connect the sensor to the electrical supply. 8 7 6 5 4 3 2 1 The electrical cables should be connected to the bottom eighth (12/24V IN) and sixth (GND) locations on the board. Do not attach the cables at locations directly next to each other. Vayyar Home Dry Contact Installation Guide 28 11 Attach the Attach the chassis to the chassis to the back cover back cover with the with the snap-fit lugs snap-fit lugs
(to ease
(to ease installation). installation) Vayyar Home Dry Contact Installation Guide 29 12 Attach the chassis to the back cover with screws. Vayyar Home Dry Contact Installation Guide 30 13 Attach the front cover to the chassis with the snap-fit lugs. Vayyar Home Dry Contact Installation Guide 31 Assembly is complete. Vayyar Home Dry Contact Installation Guide 32 Vayyar Home Dry Contact Installation Guide 33 Ceiling installation 1 Peel the stickers from the chassis and attach the sensor in place. Vayyar Home Dry Contact Installation Guide 34 2 Wrap the cable over the ribs and into the crease. Vayyar Home Dry Contact Installation Guide 35 3 Insert the USB connector. Vayyar Home Dry Contact Installation Guide 36 4 Orient the back cover according to the room wall widths the top arrows should be parralel to the x-axis. X axis
(Narrow side of room) X+
Y axis
(Wide side of room) Y+
Y-
X+
X-
X+
X-
Y-
Y-
Y+
Y+
Vayyar Home Dry Contact Installation Guide X+
37 5 Drill holes for wall plugs and insert them. Y axis
(Wide side of room) X axis
(Narrow side of room) Vayyar Home Dry Contact Installation Guide 38 6 Attach the back cover to the ceiling with screws. Vayyar Home Dry Contact Installation Guide 39 7 Alternatively, attach the back cover using cable ties/hose clamps. Vayyar Home Dry Contact Installation Guide 40 8 Connect the sensor to the electrical supply. 8 7 6 5 4 3 2 1 The electrical cables should be connected to the bottom eighth (12/24V IN) and sixth (GND) locations on the board. Do not attach the cables at locations directly next to each other. Vayyar Home Dry Contact Installation Guide 41 9
(Optional) Connect a dry contact alarm to the sensor. 8 7 6 5 4 3 2 1 Pass the cable through the bottom-center of the device, there should be a specific opening in the back cover for the cable in this location
(see illustration). The transmitter cables should be connected to the bottom first (GND) and third
(ALARM 1) locations on the board. Do not attach the cables at locations directly next to each other. Vayyar Home Dry Contact Installation Guide 42 10 Align the holes between the parts according to the required orientation
(0/45). Y axis X axis Y axis X axis Or Vayyar Home Dry Contact Installation Guide 43 Note: Ceiling mounting with a 45-degree rotation is recommended for better coverage. 11 Attach the chassis to the back cover with the snap-fit lugs (to ease installation). Vayyar Home Dry Contact Installation Guide 44 12 Attach the chassis to the back cover with screws. Vayyar Home Dry Contact Installation Guide 45 13 Attach the front cover to the assembly with the snap-fit lug. Vayyar Home Dry Contact Installation Guide 46 Assembly is complete. Vayyar Home Dry Contact Installation Guide 47 Disassembly instructions Vayyar Home Dry Contact Installation Guide 48 1 Release the snap-fit joint by inserting a flat-headed screwdriver into the top slot. Vayyar Home Dry Contact Installation Guide 49 2 Detach the screws from the chassis. Vayyar Home Dry Contact Installation Guide 50 3 Push the snap-
fit lugs towards the center and mannually detach the chassis from the back cover. Vayyar Home Dry Contact Installation Guide 51 4 Detach the elctrical cable from the sensor. Vayyar Home Dry Contact Installation Guide 52 5 Unscrew the screws from the wall/ceiling to detach the back cover. Vayyar Home Dry Contact Installation Guide 53 FCC Statement FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. For product available in the USA/Canada market, only channel 1~11 can be operated. Selection of other channels is not possible. FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body Copyright 2021 Vayyar Imaging Ltd. All rights reserved. Vayyar and Vayyar Home are trademarks and/or registered trademarks of Vayyar Imaging Ltd, 26 Shabazi St, Yehud-Monosson, Israel 5623108. Vayyar Home Dry Contact Installation Guide Vayyar.com For questions about Vayyar Home Email: homesupport@vayyar.com Copyright 2021 Vayyar Imaging Ltd. All rights reserved. Vayyar and Vayyar Home are trademarks and/or registered trademarks of Vayyar Imaging Ltd, 26 Shabazi St, Yehud-Monosson, Israel 5623108. Vayyar Home Dry Contact Installation Guide Vayyar.com