all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual rev.1 | Users Manual | 4.01 MiB | April 29 2020 / April 30 2020 | |||
1 |
|
Internal picture | Internal Photos | 1.54 MiB | April 29 2020 / April 30 2020 | |||
1 |
|
External picture | External Photos | 271.97 KiB | April 29 2020 / April 30 2020 | |||
1 |
|
Label and location | ID Label/Location Info | 963.13 KiB | April 29 2020 / April 30 2020 | |||
1 | Confidential Block Diagram | Block Diagram | April 29 2020 | confidential | ||||
1 | Confidential Operation Description | Operational Description | April 29 2020 | confidential | ||||
1 | Confidential Schematics | Schematics | April 29 2020 | confidential | ||||
1 | Datasheet-Bluetooth Antenna | Schematics | April 29 2020 | confidential | ||||
1 | Datasheet-Bluetooth IC | Schematics | April 29 2020 | confidential | ||||
1 | Datasheet-LTE Module | Schematics | April 29 2020 | confidential | ||||
1 | Datasheet-LTE antenna | Schematics | April 29 2020 | confidential | ||||
1 | Datasheet-WIFI Antenna | Schematics | April 29 2020 | confidential | ||||
1 | Datasheet-WIFI module | Schematics | April 29 2020 | confidential | ||||
1 |
|
Declaration of model difference rev.1 | Attestation Statements | 547.64 KiB | April 29 2020 / April 30 2020 | |||
1 |
|
FCC Agent | Cover Letter(s) | 524.90 KiB | April 29 2020 / April 30 2020 | |||
1 |
|
FCC Confidentiality | Cover Letter(s) | 1.00 MiB | April 29 2020 / April 30 2020 | |||
1 |
|
Report BLE rev.1 | Test Report | 3.29 MiB | April 29 2020 / April 30 2020 | |||
1 |
|
Report FCC MPE | RF Exposure Info | 380.19 KiB | April 29 2020 / April 30 2020 | |||
1 |
|
Test Setup | Test Setup Photos | 480.68 KiB | April 29 2020 / April 30 2020 |
1 | User Manual rev.1 | Users Manual | 4.01 MiB | April 29 2020 / April 30 2020 |
The Versa Cloud Services Gateway (CSG) 300 series appliances deliver highly secure site-to-site data connectivity to At a Glance small businesses and to home offices. These appliances provide the following features:
Single hardware platform that supports different CPUs and memory sizes Management Ethernet ports with dual use and dedicated options:
One RJ45 RS232 console port One USB 2.0 management port for plugging in external LTE or WiFi modems One Cu GE dual purpose port for data and management MDI and MDIX autoswitchable EoC ports PoE source support on four Ethernet ports with NIC module add-on Wireless options:
CSG350Two built-in wireless slots CSG355 and CSG365Three dedicated built-in wireless slots to support LTE External AC power supply Fan-based cooling Desktop or ceiling mount, rack-mountable in a 19 rack CSG300 Appliance Models The CSG300 appliances are available in the following models:
CSG350Compact and optimized appliance for deployment in small branches (up to 75 users) that require advanced application and cloud intelligence with hierarchical QoS, providing a cost-effective SD-WAN solution. CSG355Powerful appliance perfect for deployment in both small- and medium-sized branches that need advanced SD-Security (NGFW and UTM) along with comprehensive advanced application and cloud-intelligent SD-WANservices on-premises. CSG365High performance, powerful appliance for deployment at a medium-sized branch locations that require advanced application and cloud-intelligent SD-WAN services, advanced SD-Security (NGFW and UTM). The CSG300 appliance models provide the following CPU, memory, and storage sizes. See Table 1. Table 1: CSG300 Appliance Models https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Overview/At_a_Glance Updated: Tue, 31 Mar 2020 19:09:37 GMT Powered by 1 CSG Appliance Model CPU Memory Storage CSG350 Intel Rangeley with 4 cores CSG355 Intel Rangeley with 4 cores CSG365 Intel Rangeley with 4 cores (higher performance) 4 GB DRAM
(configurable to 16GB) 32 GB 8 GB DRAM
(configurable to 16GB) 32 GB 8 GB DRAM
(configurable to 16GB) 64 GB The CSG350 appliance is smaller in size than the CSG355 and CSG365 appliances. The CSG355 and CSG365 appliances are physically identical. Chassis Views CSG350 Appliance Figure 1 and Figure 2 show the front and rear panels of the CSG350 appliance. Note: The front panel is the side of the appliance with the SIM slots and two LEDs, for status and power. This is the side that is visible when you install the appliance in an office environment. The rear panel has the power and reset buttons and various connectors and ports. Figure 1: Front Panel of the CSG350 Appliance Figure 2: Rear Panel of the CSG350 Appliance CSG355 and CSG365 Appliance Figure 3 and Figure 4 show the front and rear panels of the CSG355. The panels for the CSG355 and CSG365 appliances are identical. Figure 3: Front Panel of the CSG355 Appliance https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Overview/At_a_Glance Updated: Tue, 31 Mar 2020 19:09:37 GMT Powered by 2 Figure 4: Rear Panel of the CSG355 Appliance https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Overview/At_a_Glance Updated: Tue, 31 Mar 2020 19:09:37 GMT Powered by 3 CSG300 Series Appliance Specifications A CSG300 series appliance chassis is made of aluminum for optimal heat dissipation. This article lists the chassis and regulatory compliance specifications for the CSG300 series appliance. It also lists certifications and export control classification numbers (ECCNs) for the appliance. Chassis Specifications CSG350 Appliance Table 1 lists the specifications for a CSG350 appliance chassis. Item Specification Table 1: CSG350 Series Chassis Specifications Services and Slot Density RJ-45 ports 10/100/1000 Mbps External USB ports (USB 2.0) RJ-45 serial console port 4 1 1 Memory DDR4 ECC DRAM 4 GB Disk 1 SSD default size 32 GB Disk 2 and Disk 3, USB-based Flexible Power supply 12VDC, 5A Power Adapter Specifications AC input voltage 100240 Volts AC input line frequency 5060 Hz Typical power consumption 25 Watts Chassis Physical Specifications https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Components_and_Specifications/01_CSG Updated: Tue, 31 Mar 2020 17:58:46 GMT Powered by 1 Item Specification Chassis height 1.38 (34 mm) Chassis width 7.87 (200 mm) Chassis depth 5.91" (152 mm) Chassis weight Package Specifications Package height 7" (17.78 cm) Package width 16.7" (42.4 cm) Package depth 12" (30.48 cm) Package weight 15.4 lb (7 kg) Operating Conditions 2.75 lb (1.25 kg) Chassis weight with installation kit: 1.8 kg maximum Temperature 0 to 40C (32 to 104F) at sea level Humidity Altitude Noise level Humidity Reliability MTBF 10 to 85% relative humidity Maximum 3000 m (10000 ft) Less than 20 dBA 10 to 85% relative humidity Minimum of 70,000 hours Storage Conditions Temperature 20 to 70C (68 to 158F) at sea level CSG355 and CSG365 Appliance Table 2 lists the specifications for a CSG355 and CSG365 appliance chassis. https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Components_and_Specifications/01_CSG Updated: Tue, 31 Mar 2020 17:58:46 GMT Powered by 2 Table 2: CSG355 and CSG365 Chassis Specifications https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Components_and_Specifications/01_CSG Updated: Tue, 31 Mar 2020 17:58:46 GMT Powered by 3 Item Specification Services and Slot Density RJ-45 ports 10/100/1000 Mbps 4 + 2 External USB ports (USB 2.0) RJ-45 serial console port 2 1 Memory DDR4 ECC DRAM Disk 1 SSD default size CSG355: 8 GB CSG365: 8 GB CSG355: 32 GB CSG365: 64 GB Disk 2 and Disk 3, USB-based Flexible Power supply 12VDC, 5A Power Specifications AC input voltage 100240 Volts AC input line frequency 5060 Hz Typical power consumption 33 Watts Chassis Physical Specifications Chassis height 1.65 (43 mm) Chassis width 13.8 (370 mm) Chassis depth 6.7 (172 mm) Rack height 1 RU Chassis weight Package Specifications Package height 7" (17.78 cm) Package width 16.7" (42.4 cm) Chassis weight with installation kit: 2.5 kg maximum https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Components_and_Specifications/01_CSG Updated: Tue, 31 Mar 2020 17:58:46 GMT Powered by 4 Package depth 12" (30.48 cm) Package weight 15.4 lb (7 kg) Operating Conditions Temperature 0 to 40C (32 to 95F) at sea level Humidity Altitude Noise level Humidity Reliability MTBF 10 to 85% relative humidity Maximum 3000 m (10000 ft) Less than 30 dBA 10 to 85% relative humidity Minimum of 70,000 hours Storage Conditions Temperature 20 to 70C (68 to 158F) at sea level Regulatory Compliance Table 2 lists the regulatory compliance specifications for a CSG300 series chassis. Table 2: CSG300 Series Regulatory Compliance Specifications Item Specification Safety CE Marketing Security EMC Environmental RoHS TPM 2.0 Designed to be FIPS 140-2 Level 2 compliant CE EMC, EN55032 Class A; FCC Part 15, Class A https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Components_and_Specifications/01_CSG Updated: Tue, 31 Mar 2020 17:58:46 GMT Powered by 5 Certifications A CSG300 series appliance complies with the certificates listed in Table 3. Table 3: CSG300 Series Certifications Region Certifications EN 300 328 (Bluetooth) EN 301 489-1 EN 301 489-17 (Bluetooth) Europe EN 50385 MPE(SAR Evaluation) EN 55032 EN 60950-1 CE(LVD) FCC 47 CFR Part 15B FCC 47 CFR Part 15C, 15.247 (Bluetooth) America MPE Contain FCC ID: N7NEM7455(For models with LTE) Contain FCC ID: 2ARF9CSG-W1(For models with WIFI) Japan TBD once Japan has completed their testing Export Control Information Table 4 lists the ECCN, HTS, and CCATS numbers. Table 4: ECCN, HTS, and CCATS Numbers Item ECCN Number HTS Number CCATS Number Use of item by Versa MatrixSSL software module 5E002 8542310000 G161333 QuickSec IPsec toolkit as used by Versa Analytics, Versa Director and Versa FlexVNF 5D002 8542310000 G161333 Hardware-based encryption and decryption 5A002U 8542310001 G156910L1 SSL-VPN Proxy IPSec crypto module CSG300 series https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Components_and_Specifications/01_CSG Updated: Tue, 31 Mar 2020 17:58:46 GMT Powered by 6 Item ECCN Number HTS Number CCATS Number Use of item by Versa appliance https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Components_and_Specifications/01_CSG Updated: Tue, 31 Mar 2020 17:58:46 GMT Powered by 7 Front and Rear Panel Components This article describes the front and rear panel components of a CSG300 series appliance. For the exact location of these components on the appliance, see At a Glance. The front panel of a CSG300 series appliance has two status LEDs. Front Panel LEDs Table 1 lists the LEDs, their colors and states, and the status they indicate. Table 1: Front Panel LEDs in a CSG300 Series Appliance LED Color Status Power Green Off: Appliance is not powered on. Green: Appliance is powered on. Off: Appliance hardware is up, but there is a problem with the software. Solid green: Appliance is up and running. Blinking green: Appliance is in the process of booting up. Red: Major error condition exists in the system or there is a corrupt software configuration. Blinking red: System crash, overheating, or a persistent error condition exists. Status Green, Red Rear Panel LEDs The rear panel of a CSG300 series appliance has power and reset buttons and six status LEDs. The rear panel of a CSG300 series appliance has six LEDs located in two rows. https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Components_and_Specifications/02_Front Updated: Wed, 01 Apr 2020 18:52:43 GMT Powered by 1 Table 2 lists the LEDs, their color and states, and the status they indicate. LED Color Status Table 2: Rear Panel LEDs in a CSG300 Series Appliance Power Green Off: Appliance is not powered on. Green: Appliance is powered on. Status Green, Red Off: Appliance hardware is up, but there is a problem with the software. Solid green: Appliance is up and running. Blinking green: Appliance is in the process of booting up. Red: Major error condition exists in the system or there is a corrupt software configuration. Blinking red: System crash, overheating, or a persistent error condition exists. Wireless White Solid white: Wireless module is up and running. Off: Wireless module not installed. Blinking white: Wireless module is booting up or there is traffic on the wireless module. LTE White Solid white: LTE module is up and running. Off: LTE module not installed, or there is a major hardware problem. Blinking white: LTE module is booting up or there is traffic on the LTE module. The rear panel of a CSG300 series appliance has two nano-SIM card slots. If you subscribe to a single wireless service, use the SIM 1 slot to install the LTE device. If you are subscribing to dual wireless service, use both the SIM 1 and SIM 2 slots to activate the LTE devices. It is strongly recommended that you use only preactivated SIMs in the SIM card slots. SIM Card Slots Power Button The Power button on the rear panel of a CSG300 series appliance turns the power on and off. To turn the power on, press and immediately release the Power button when the appliance is off. https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Components_and_Specifications/02_Front Updated: Wed, 01 Apr 2020 18:52:43 GMT Powered by 2 To turn the power off, press the Power button when the appliance is on. If you press and immediately release the button, the appliance shuts down gracefully. If you press and hold the button for a longer period, it turns off power to the appliance ands shuts it down. Reset Button The Reset button on the rear panel of a CSG300 series appliance resets the appliance. The reset functionality depends on the number of times you press it, as described in Table 3. The Reset button is recessed so that it is not accidentally pressed while the appliance is operational. To press the Reset button, use a sharp narrow tool. Each time you press the Reset button, you hear a buzzer sound. Number of Presses Behavior Table 3: Reset Button Press Behavior 2 4 6 8 Reset the appliance to the factory-default snapshot. Reset the appliance to the branch prestaging configuration. Reset the appliance to the branch staging configuration. Reset the appliance to branch post-staging configuration. https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Components_and_Specifications/02_Front Updated: Wed, 01 Apr 2020 18:52:43 GMT Powered by 3 LTE Modem Module The CSG300 series LTE modem module is a high-performance Cat-6 LTE Advanced modem that provides up to 300 Mbps download speeds and 50 Mbps upload speeds. The LTE modem supports multiple carriers, and it has been certified by major global carriers. The appliance has two externally accessible SIM card slots, one for each embedded LTE-A modem. If the appliance is configured with two LTE-A modems, each SIM card is used to control one LTE radio each. The appliance also has one USB slot that can be connected to an LTE dongle if desired. With two internal modems and one USB attached modem, you can deploy up to three simultaneous LTE WAN connections. The LTE firmware-driven modem module provides the following capabilities:
Externally accessible SIM cards that support dual-LTE modems. Connects to most global carrier's network based on the SIM card inserted. For example, if a SIM card is inserted from carrier A, the modem will auto-detect the SIM card and connect to carrier A's network. If a SIM card is inserted from carrier B, the modem will connect to the network of carrier B. Global navigation satellite system (GNSS) receiver enables tracking and location-based services. Stores up to three firmware versions, thereby allowing the modem to switch to other networks. Firmware can be upgraded over the air. Secure boot provides secure connectivity by preventing unauthorized code on target devices. The LTE modem connections are metered connections, and the Versa software implementation ensures that the LTE service is charged only when needed. Policies and scenarios that determine the use of LTE interfaces are set by network operators and implemented by Versa FlexVNF accordingly. Table 1 lists the supported LTE specifications. Specification APAC Modem Americas and EMEA Modem Table 1: LTE Specifications 300/50 Mbps 300/50 Mbps Peak download/
upload rate Frequency bands 4GLTE Frequency bands 3G WCDMA 1, 3, 5, 7, 8, 18, 19, 21, 28, 38, 39, 40, and 41 1 through 5, 7, 8, 12, 13, 20, 25, 26, 29, 30, and 41 1, 5, 6, 8, 9, and 19 1, 2, 3, 4, 5, 8 https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Components_and_Specifications/04_LTE_ Updated: Wed, 01 Apr 2020 18:54:26 GMT Powered by 1 Specification APAC Modem Americas and EMEA Modem Frequency bands 3G SCDMA 39 Location Solution Approvals Certified Carriers Supported carrier aggregation 1 + (8, 18, 19 ,21), 3 + (5, 7, 19, 28), 7 + (5, 7, 28), 19 + 21, 38 + 38, 39 + 39, 40 + 40, and 41
+ 41 1 + 8, 2 + (2, 5, 12, 13, 29), 3 + (7, 20), 4 + (4, 5, 12, 13, 29), 7 + (7, 20), 12 +30, 5 + 30, and 41+41 Standalone, Xtra, SUPL 1.0 & 2.0, GLONASS, Standalone, Xtra, SUPL 1.0 & 2.0, GLONASS, Galileo, BeiDou Galileo, BeiDou CE, GCF, JRF/JPA, KC, NCC CE, FCC, GCF, IC, NCC, PTCRB NTT Docomo, Telstra, KDDI, Softbank AT&T, Bell, Rogers, Sprint, Telus, Verizon, Vodafone, US Cellular, Anatel You can order CSG300 series appliances with an optional LTE modem module. The LTE modem modules have either one SIM slot or two SIM slots. For modules with one SIM slot, you insert the SIM card into the SIM1 slot, which is on the front of the appliance. For modules with two SIM slots, you insert a SIM card into each of the two SIM slots, which are labeled SIM1 and SIM2. If the appliance is off when you insert the SIM card or cards, the LTE functionality is activated when you boot the appliance. If you insert the SIM card or cards into the LTE modem module when the appliance is on and operational, you must reboot the appliance to restart the LTE modem and LTE functionality. To do this, you must power off the appliance, unplug the power cable, plug the power cable back in, and press the power button. Simply powering the appiance on and off does not restart the LTE modem. Also, pressing the reset button on the appliance or rebooting the appliance from Versa Director does not restart the LTE modem. https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Components_and_Specifications/04_LTE_ Updated: Wed, 01 Apr 2020 18:54:26 GMT Powered by 2 Wireless Options The CSG350 appliance has two internal wireless slots which can be configured for single LTE or dual LTE. The CSG355 and CSG365 appliances have three internal wireless slots. The CSG300 series appliances have one WiFi Access Point (AP) module. The WiFi AP module is a dual-band module that simultaneously supports 2.4 GHz, for longer distances, and 5 GHz, for faster throughput. It provides the following WiFi capabilities:
WiFi radios preconfigured for 2.4GHz or 5.0-GHz operation DFS frequency bands, enabled by default, thereby providing more frequency bands for 5 GHz radio 802.11ac Wave 2 standard and 2x2:2 Multi User Multiple Input Multiple Output (MU-MIMO) for more efficient transmission to multiple clients Built-in WiFi mesh capabilities Bluetooth for ZTP and smartphone applications IEEE 802.11a, 802.11b, 802.11g, 802.11n, and 802.11ac protocols Channel bandwidth of 20 MHz, 40 MHz, and 80 MHz Channel bonding with channel bandwidths of 5 MHz, 10 MHz, 20 MHz, and 40 MHz Background scanning automatically selects the best and cleanest channel Up to 512 concurrent clients across both frequencies, while each radio supports up to 255 clients Up to 16 SSIDs simultaneously Certified for FCC and CE Client steering capabilities across respective frequency bands based on load and number of clients in each frequency thereby allowing end devices to have optimum experience The WiFi AP module has a hardware-based cryptographic engine that includes secure boot. WiFi security is provided by 802.11i, AES-CCMP, AES-GCMP, PRNG, TKIP, WAPI, WEP, WPA, WPA2, and WPS based encryption methods. You can seamlessly integrate the WiFi AP module with Versa FlexVNF features, including over-the-air traffic analysis and other analytics. FlexVNF provides queuing mechanisms, including weighted round-robin (WRR). In addition, the WiFi AP module has a built-in QoS feature that prioritizes and manages over-the-air traffic. It also has built-in spectrum analyzer capabilities to detect rogue frequencies in an environment, if desired. https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Components_and_Specifications/05_Wirel Updated: Wed, 01 Apr 2020 18:55:06 GMT Powered by 1 Interface Numbering Figure 1 shows mapping of the Ethernet ports to Virtual Network Interface (VNI) numbering for the CSG350. Figure 1: Port-to-VNI Mapping - CSG350 Figure 2 shows port-to-VNI mapping for the CSG355 and CSG365. Note that the CSG355 and CSG365 chassis are identical. Figure 2: Port-to-VNI Mapping - CSG355 and CSG365 https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Components_and_Specifications/06_Interf Updated: Wed, 01 Apr 2020 18:55:33 GMT Powered by 1 Power Supply and Airflow This article describes the AC power supply and airflow requirements for CSG300 appliances. AC Power Supply for CSG300 Series Appliances By default, CSG300 series appliances ship with one AC power supply unit. If you order the CSG300 series appliance with the power over Ethernet (PoE) NIC module, an additional power supply unit ships with the appliance. Table 1 describes the AC power supply specifications for each power supply unit. Table 1: CSG300 Series Appliance AC Power Supply Specifications Item AC input voltage Specification 100240 Volts AC input line frequency 5060 Hz Typical power consumption with PoE disabled 35 Watts Typical power consumption with PoE enabled 60 Watts Airflow Requirements The appliance is cooled by a fan. The CSG300 series appliance is made of aluminum for optimal heat dissipation. When planning your site for installing a CSG300 series appliance in a 19-inch rack, allow a minimum of 0.5 RU space on each side of the appliance to allow hot air to flow out of the appliance. When placing a CSG300 series appliance on a desk, ensure that the vents on the side of the unit are never blocked, to allow hot air to flow out of the appliance. Covering the vents prevents heat from dissipating out of the appliance, which will cause the chassis to overheat and then shut down. https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Components_and_Specifications/07_Powe Updated: Wed, 01 Apr 2020 18:56:14 GMT Powered by 1 This article provides general safety standards and warnings relating to installing or connecting a CSG300 series Installation Guidelines appliance. General Safety Guidelines Caution: Before installing or removing a CSG300 series appliance, ensure that the appliance chassis is electrically connected to ground. When you are installing or removing an appliance, ensure that you wear an ESD grounding wrist strap. To put the ESD grounding strap on properly, attach it to an ESD point and then place the other end of the strap around your bare wrist, making good skin contact. Failure to use an ESD grounding strap could damage the appliance. Install the CSG300 series appliance in compliance with the following local, national, and international electrical codes:
United StatesNational Fire Protection Association (NFPA 70), United States National Electrical Code. Other countriesInternational Electromechanical Commission (IEC) 60364, Part 1 through Part 7. Evaluated to the TN power system. CanadaCanadian Electrical Code, Part 1, CSA C22.1. Locate the emergency power-off switch in the installation area. In case of an electrical accident, turn off the power quickly. Disconnect power to the appliance before installing or removing it. Disconnect power from the circuit that is being used for the appliance. If hazardous conditions exist, do not work alone. If you are working under conditions that might be hazardous to the eyes, wear safety glasses or goggles. Risk of explosion if the battery is replaced by an incorrect type. Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Planning_and_Installation/01_Installation_ Updated: Wed, 01 Apr 2020 18:57:04 GMT Powered by 1 the user will be required to correct the interference at his own expense. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be collocated or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement:
This equipment complies with CE and FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. Operation of this equipment in a residential environment could cause radio interference. Operation of this equipment is for indoor use only. https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Planning_and_Installation/01_Installation_ Updated: Wed, 01 Apr 2020 18:57:04 GMT Powered by 2 To prepare your site for installing a CSG300 series appliance, follow the guidelines and requirements listed in this Prepare the Site for Installation article. Site Preparation Guidelines Install the appliance in an enclosed and secure environment, and allow only authorized personnel to access the device. Keep the area around the appliance free from dust and conductive material. Follow ESD prevention procedures to avoid any damage to the appliance. Environmental Requirements Ensure that the area in which you operate the appliance has adequate air circulation so that the cooling system functions normally. Ambient air temperature may not be sufficient to cool the chassis to acceptable operating temperatures without adequate circulation. Avoid temperature extremes. High humidity conditions can cause moisture to penetrate into the chassis. The appliance can operate in relative humidity of 10% to 85%, non-condensing. You can mount a CSG300 series appliance in a 19-inch four-post rack using slide rails. Table 1 lists the rack Rack Requirements requirements. Table 1: Rack Requirements for a CSG300 Series Appliance Requirement Guidelines Rack type Use a 19-inch four-post rack that has bracket holes spaced at 1 U (1.75 in. or 4.45 cm) increments, and that has panels strong enough to support the weight of the appliance. Rack size Comply with the size and strength standards of a 19-inch rack. Ensure that the rack rails are spaced wide enough to accommodate the external dimensions of the appliance chassis. Ensure that the spacing of rails and the adjacent racks allows for proper clearance around the appliance and the rack. Rack firmly Secure the rack to floor brackets and to ceiling brackets to ensure maximum stability. https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Planning_and_Installation/02_Prepare_the Updated: Wed, 01 Apr 2020 19:00:38 GMT Powered by 1 Requirement Guidelines secured to building structure Airflow Requirements the appliance. A CSG300 series appliance uses fan-based cooling. Passive cooling occurs by airflow through the vents on the side of When planning your site for installing a CSG300 series appliance in a 19-inch rack or on a desk, ensure that the vents on the side of the unit are never blocked, to allow hot air to flow out of the appliance. Covering the vents prevents heat from dissipating out of the appliance, which will cause the chassis to overheat and then shut down. https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Planning_and_Installation/02_Prepare_the Updated: Wed, 01 Apr 2020 19:00:38 GMT Powered by 2 Install a CSG300 Series Appliance This article provides instructions about how to unpack a CSG300 series appliance and mount it in a 19-inch rack. Unpack a CSG300 Series Appliance The CSG300 series appliance is packed in a plastic box, and it is shipped in a cardboard carton, secured with foam packing material. The carton also contains an accessory box. It is recommended that you unpack the appliance only when you are ready to install it. To unpack a CSG300 series appliance:
1. Open the top flaps of the cardboard carton. 2. Remove from the box the foam packing material holding the appliance and the accessories in place. See Figure 1. 3. Remove the accessory box and the appliance from the foam packing material. 4. Remove the accessories from the accessories box. 5. Verify the components against the packing list that is included in the box. Figure 1: Unpack a CSG300 Series Appliance https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Planning_and_Installation/03_Install_a_CS Updated: Wed, 01 Apr 2020 19:02:26 GMT Powered by 1 It is recommended that you save the shipping carton and packing material when unpacking the appliance, in case you need to later move the appliance or return it. See Return Hardware. Packing List for a CSG300 Series Appliance The cardboard carton in which a CSG300 series appliance is shipped contains a packing list. Check the packing list against the parts that you receive in the shipping carton. Packing List for the CSG350 Need information here... Table 1 lists the parts shipped with a CSG350 appliance. Table 1: Parts Shipped with a CSG350 Series Appliance Components Quantity CSG300 series appliance chassis AC power adapter Power cable Cat 6 cable Cat 5e cable GPS antenna Rack-mounting ears Screws for mounting ears 1 1 1 1 1 2 1 2 8 LTE antenna (included with LTE module only) 2 for single LTE module 4 for dual LTE module WiFi antenna (included with WiFi module only) Packing List for the CSG355 and CSG365 Table 2 lists the parts shipped with a CSG355 and CSG365 appliance. Table 2: Parts Shipped with a CSG355 and CSG365 Appliance https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Planning_and_Installation/03_Install_a_CS Updated: Wed, 01 Apr 2020 19:02:26 GMT Powered by 2 Components Quantity CSG300 series appliance chassis AC power adapter Power cable Cat 6 cable Cat 5e cable GPS antenna Rack-mounting ears Screws for mounting ears 1 1 1 1 1 2 1 2 LTE antenna (included with LTE module only) 2 for single LTE module 4 for dual LTE module WiFi antenna (included with WiFi module only) 6M4x8 mm #6 Torque: 1.18+/-0.05 N.M. 4#12-24, 12.7 mm Torque: 3.2+/-0.05 N.M. Mount a CSG300 Series Appliance in a Rack You can mount a CSG300 series appliance in a four-post 19-inch rack. Two people are required to mount the appliance. To mount the appliance, ensure that you have the following tools:
Number 2 Phillips (+) screwdriver Tape measure To mount a CSG300 series appliance in a four-post 19-inch rack:
1. Place the appliance chassis on a flat, stable surface. 2. Check the internal dimensions of the rack with a tape measure. The appliance is 22 cm wide (about 8.6 inches wide) and must fit within the mounting posts. 3. Allow a minimum of 0.5 RU space above the appliance for airflow, to allow hot air to flow out. However, it is recommended that you allow 1 RU space above the appliance. Figure 2: Space a CSG300 Series Appliance when Rack Mounting https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Planning_and_Installation/03_Install_a_CS Updated: Wed, 01 Apr 2020 19:02:26 GMT Powered by 3 4. Attach the two mounting ears to each side of the appliance chassis using the eight mounting ear screws that are shipped with the appliance. Use four screws to attach each mounting ear. Figure 3: Attach the Mounting Ears to a CSG300 Series Appliance 5. Grasp both sides of the appliance chassis, making sure that the front of the chassis is facing you. 6. Stand in front of the rack and lift the chassis. Then, gently insert the chassis into the rack and slide it as far back as possible. Figure 4: Insert a CSG300 Series Appliance into the Rack 7. Have the second person secure the mounting ears to the front of the rack using the rack-mount screws that are shipped with the appliance. Insert and then tighten the screws. Figure 5: Secure the Mounting Ears to the Rack https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Planning_and_Installation/03_Install_a_CS Updated: Wed, 01 Apr 2020 19:02:26 GMT Powered by 4 https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Planning_and_Installation/03_Install_a_CS Updated: Wed, 01 Apr 2020 19:02:26 GMT Powered by 5 Connect a CSG300 Series Appliance This article describes how to connect a CSG300 series appliance to an AC power source and to a management console. Step 1: Connect Earth Ground to a CSG300 Series Appliance To ensure proper operation of a CSG300 series appliance and to meet safety and electromagnetic interference (EMI) requirements, you must connect the appliance to earth ground before you connect power to the appliance. The CSG300 series appliance requires a three-prong power cable. You must connect the appliance to earth ground before you connect power to the appliance:
1. Connect one end of the grounding cable to a proper earth ground, such as the rack in which the CSG300 series appliance is mounted. 2. Secure the grounding lug to the protective grounding terminal with washers and screws. Step 2: Connect AC Power to a CSG300 Series Appliance Before you begin connecting AC power to a CSG300 series appliance, ensure that you have:
Electrostatic discharge (ESD) wrist strap. AC power cord shipped with the appliance. The cord has plugs appropriate for your geographical location. To connect a CSG300 series appliance to an AC power source:
1. Attach one end of the ESD grounding strap to your bare wrist, and connect the other end to the ESD point on the rack. 2. Plug one end of the AC power cord into the power supply in the appliance. 3. Plug the other end of the AC power cord into an AC power source outlet. 4. Plug the DC end of the power supply unit into the back of the CSG300 series appliance. Step 3: Connect a CSG300 Series Appliance to a Management Console You can configure and manage a CSG300 series appliance using a management console. Use a cable with an RJ-45 connector to connect the CSG300 series appliance to the management console. To connect a CSG300 series appliance to a management console:
https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Planning_and_Installation/04_Connect_a_ Updated: Wed, 01 Apr 2020 18:57:41 GMT Powered by 1 1. Plug one end of the console cable into the console port located on the rear panel of the CSG300 series appliance. 2. Plug the other end of the cable into the console server or into a management console. https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Planning_and_Installation/04_Connect_a_ Updated: Wed, 01 Apr 2020 18:57:41 GMT Powered by 2 Return Hardware This article describes how to return a CSG series appliance for return or replacement. Locate the Model and Serial Number To return a CSG series appliance to Versa Networks, you need the model and serial number of the appliance. These numbers are printed on the shipping box and on the unit label located on the bottom of the appliance. Obtain an Return Material Authorization If you are returning an appliance to Versa Networks, open a support case with the Versa Networks Customer Support team and obtain a Return Material Authorization (RMA) number. Before you open a case and request an RMA number, have the following information ready:
Your existing case number, if any Serial and model numbers of the appliance Physical location of the appliance Failure or problem description with details To obtain an RMA number:
Your name, organization name, telephone number, fax number, and shipping address 1. Open a support case with Versa Networks in one of the following ways:
Log in to https://support.versa-networks.com/support/login Call toll-free 1-888-498-5810 2. A customer support representative will validate your case and issue an RMA number for use to use when returning the appliance to Versa Networks. Repack the Appliance To return a CSG series appliance, repack it in its original packing. You need the following tools to do this:
Phillips Number 2 (+) screwdriver Original cardboard carton in which you received the appliance https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Maintenance/Return_Hardware Updated: Wed, 01 Apr 2020 18:58:08 GMT Powered by 1 To repack the appliance in its original packing:
1. Shut down the CSG series appliance. 2. Disconnect power to the appliance and remove all cables. 3. If the appliance is mounted in a 19-inch rack, unscrew the mounting ears and gently slide the chassis out of the rack. 5. Secure the chassis in the cardboard carton, placing the side packing foam on both sides of the appliance 4. Place the chassis in the plastic packing bag. chassis and the top packing foam over the top. 6. Close the cardboard carton and seal it with packing tape. 7. Write the RMA number on the shipping label or on the outside of the box for tracking purposes. https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Maintenance/Return_Hardware Updated: Wed, 01 Apr 2020 18:58:08 GMT Powered by 2
1 | Label and location | ID Label/Location Info | 963.13 KiB | April 29 2020 / April 30 2020 |
CSG300s Label Instruction Revision A Description Initial release Date Feb. 10, 2020 100.00 100.00 C1 C1 Versa Networks INC Versa Networks INC Model:CSG355 REV:A REV:A ARIAL 11 Model Barcode ARIAL 11 Model Barcode Input Rated: 12V , 5A This device complies with Part 15 of the FCC Rules. Operation is subject to the This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
(2) this device must accept any interference received, including interference that may cause undesired operation. may cause undesired operation. P/N:JVASBXXXXXXX P/N:JVASBXXXXXXX SN:XXXXXXX SN:XXXXXXX MAC:XXXXXXX MAC:XXXXXXX ARIAL 11 Model Barcode ARIAL 11 Model Barcode ARIAL 11 Model Barcode ARIAL 11 Model Barcode ARIAL 11 Model Barcode ARIAL 11 Model Barcode FCC ID: 2ARF9CSG3X5 Manufacturer:Versa Networks Inc. Manufacturer:Versa Networks Inc. Address:6001 America Center Dr, 4th floor, Address:6001 America Center Dr, 4th floor, Suite 400, San Jose, CA 95002, USA Suite 400, San Jose, CA 95002, USA Made In Malaysia Made In Malaysia 0 0 5 5
. 4 4 4 4 1 1 Notes:
The version is only for reference. Please follow the latest version on Windchill. 100.00 C1 Versa Networks INC Model:CSG365 REV:A ARIAL 11 Model Barcode Input Rated: 12V , 5A This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. P/N:JVASBXXXXXXX SN:XXXXXXX MAC:XXXXXXX ARIAL 11 Model Barcode ARIAL 11 Model Barcode ARIAL 11 Model Barcode FCC ID: 2ARF9CSG3X5 Manufacturer:Versa Networks Inc. Address:6001 America Center Dr, 4th floor, Suite 400, San Jose, CA 95002, USA Made In Malaysia 0 5
. 4 4 1 Notes:
The version is only for reference. Please follow the latest version on Windchill. 100.00 C1 Versa Networks INC Model:CSG355-WLA REV:A ARIAL 11 Model Barcode Input Rated: 12V , 5A This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. P/N:JVASBXXXXXXX SN:XXXXXXX MAC:XXXXXXX IMEI:XXXXXXX ARIAL 11 Model Barcode ARIAL 11 Model Barcode ARIAL 11 Model Barcode ARIAL 11 Model Barcode FCC ID: 2ARF9CSG3X5 Contain FCC ID: N7NEM7455 Contain FCC ID: 2ARF9CSG-W1 Manufacturer:Versa Networks Inc. Address:6001 America Center Dr, 4th floor, Suite 400, San Jose, CA 95002, USA Made In Malaysia 0 5
. 4 4 1 Notes:
The version is only for reference. Please follow the latest version on Windchill. 100.00 C1 Versa Networks INC Model:CSG365-WLA REV:A ARIAL 11 Model Barcode Input Rated: 12V , 5A This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. P/N:JVASBXXXXXXX SN:XXXXXXX MAC:XXXXXXX IMEI:XXXXXXX IMEI:XXXXXXX ARIAL 11 Model Barcode ARIAL 11 Model Barcode ARIAL 11 Model Barcode ARIAL 11 Model Barcode ARIAL 11 Model Barcode FCC ID: 2ARF9CSG3X5 Contain FCC ID: N7NEM7455 Contain FCC ID: 2ARF9CSG-W1 Manufacturer:Versa Networks Inc. Address:6001 America Center Dr, 4th floor, Suite 400, San Jose, CA 95002, USA Made In Malaysia 0 5
. 4 4 1 Notes:
The version is only for reference. Please follow the latest version on Windchill. Front : ARIAL BLACK Size20 Versa Networks INC Front : ARIAL Size12 I.T.E. E508861 Model:CSG355 REV:A ARIAL 11 Model Barcode Input Rated: 12V , 5A Front : ARIAL Size12 Front : ARIAL Size10 Front : ARIAL Size12 Front : ARIAL Size6 Front : ARIAL Size5 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. P/N:JVASBXXXXXXX SN:XXXXXXX MAC:XXXXXXX IMEI:XXXXXXX IMEI:XXXXXXX FCC ID: 2ARF9CSG3X5 ARIAL 11 Model Barcode ARIAL 11 Model Barcode ARIAL 11 Model Barcode ARIAL 11 Model Barcode ARIAL 11 Model Barcode Manufacturer:Versa Networks Inc. Address:6001 America Center Dr, 4th floor, Suite 400, San Jose, CA 95002, USA Front : ARIAL Size5 Made In Malaysia NOTE:
Barcodes: Code 39 or 128, Grade C or better 13mm 12.4mm 4.5mm 3.7mm 9 m m 9 m m
. 5 5 m m FCC ID Label Model CSG355 CSG355-W CSG355-LA CSG355-2LA CSG355-WLA CSG365 CSG355-W CSG365-LA CSG365-2LA CSG365-WLA FCC ID: 2ARF9CSG3X5 FCC ID: 2ARF9CSG3X5 Contain FCC ID: 2ARF9CSG-W1 FCC ID: 2ARF9CSG3X5 Contain FCC ID: N7NEM7455 FCC ID: 2ARF9CSG3X5 Contain FCC ID: N7NEM7455 FCC ID: 2ARF9CSG3X5 Contain FCC ID: N7NEM7455 Contain FCC ID: 2ARF9CSG-W1 FCC ID: 2ARF9CSG3X5 FCC ID: 2ARF9CSG3X5 Contain FCC ID: 2ARF9CSG-W1 FCC ID: 2ARF9CSG3X5 Contain FCC ID: N7NEM7455 FCC ID: 2ARF9CSG3X5 Contain FCC ID: N7NEM7455 FCC ID: 2ARF9CSG3X5 Contain FCC ID: N7NEM7455 Contain FCC ID: 2ARF9CSG-W1 Label Location
1 | Declaration of model difference rev.1 | Attestation Statements | 547.64 KiB | April 29 2020 / April 30 2020 |
VSN 20066 VO esor URS OOF MING OOY Wy IC JoyUED BoLIOUTY [009 SYIOMJON BS.ADA,
(1eseq |IUIN) Ayiqe!, Buipuodse.u09 seaq ||IM aM Qsjej JJ an} Ajje}o} sue Auedwiod 4NO Jo SjUsWAa}e}S PeuOoMUsWW-sAoge syuL Id-IM + SSPZWSA SL] + Pibog UOlsusyXg + Pjeod UIEW S9EHSD VIM-S9E9DSD SSvVZWa AL] + SSPZWA AL] + Psbog UO!suSyxXg + Pjeog URL GOEHSD W1@-S9DS9 SSPZWA JL] + pieog uolsueyxe + pueog uleW G9ENSO V1-S9EDSD l4-IM + P4bog udlsua}xe + pseog ule gG9EosD M-SSEDSD pieog uolsuayxe + pikog uleW g9eNSo g9EDSO I4-IM + SSbZWA SLT + PibOg UOIsUaIXA + P4eog UIE GGEHsD VIM-SSEDSD SSbZWa All + SSPZWA AL] + Psbog UOIsUSIxXy + Pseog ule GgEeOsd VW12@-SSEDSD SSPZWA SL] + Pieod UOISUS}Xe + psieog ule GSEHSD V1-SSEDS9 I4-IM + p4eog uolsua}xe + pueog ulew ggeoso M-SSEDSD pieog uolsueqxe + pseog ulew Ggeoso SSEDSO uoneimnbiyuoD SOA SOA pie) JIN Moddns SOA Sa, pieog uoisua}xXq avo aOcE ZHOP'T (84109 v) 9TSZD JOssed01g WO}y [23UT ZHOv'Z (84109 v) 8GS7D J0SsE901g WOW |e3UI Selisg G9EDSO Soudssajig
:mojeq 1ds0xqg pueog ulew swes su} pesn pue jeoquEp! DUps]e se SSE9DSO M-SSEDSD V1-SSEDSO V1Z-SSEDSO VIM-SSEDSO S9E9S)9 M-S9EDSD V1-S9EDSD V1Z-S9EDSO VIM-S9EDSD :1SPOW ABM3}{eH SSdIAISS pNnojD pefoid s,Auedwos ino BLSP SYIOMION SABA OM NOILVAV Todd
1 | FCC Agent | Cover Letter(s) | 524.90 KiB | April 29 2020 / April 30 2020 |
Versa Networks Inc. 6001 America Center Drive, Suite 400 San Jose. CA 95002 www. versa-networks.com Phone (408)-385-7660 Authority to Act as Agent Date: _ American Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern:
Intertek Testing Services Shanghai is authorized to act on our behalf, until otherwise notified, for applications to American Certification Body, Inc. (ACB).
We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Expiration Date:
ny hk B Me pr i ure (Print name) fahite Cura Title:
On behalf of: versa Network
(Company Name) Telephone:
| _ Ifa group entity is designated as the authorized agent, the letter of authorization must identify those individuals within the group who are authorized to take action on the application; or alternatively a statement must be provided indicating that as the authorized agent, any individual within the group entity is authorized to act on behalf of the applicant /
grantee and take action on the application. See 012916 09
1 | FCC Confidentiality | Cover Letter(s) | 1.00 MiB | April 29 2020 / April 30 2020 |
Versa Networks Inc. 6001 America Center Drive, Suite 400 San Jose. CA 95002 www. versa-networks.com Phone (408)-385-766U Request_for Confidentiality Date:
Subject: Confidentiality Request for:
Pursuant to FCC 47 CRF 0.457(d) and 0.459 and IC RSP-100, Section 12.4, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit
[_] Short Term [<x] Permanent Block Diagrams
[_] Short Term External Photos
[_] Short Term [_] Permanent*! Internal Photos
[_] Short Term Permanent Operation Description/Theory of Operation
[_] Short Term [_] Permanent Parts List & Placement/BOM
[_] Short Term [_] Permanent Tune-Up Procedure
[(_] Short Term [X] Permanent Schematics
[-] Short Term Test Setup Photos
[_] Short Term [_] Permanent* Users Manual ,
*Note: (Insert Explanation as Necessary) has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they
~ have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality:
The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality:
The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of __ (specify number of days not to exceed 180) ___ days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify ACB in the event information regarding the product or the product is made available to the public. ACB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. NOTE for Industry Canada Applications:
The applicant understands that until such time that IC distinguishes between Short Term and Permanent Confidentiality, either type of marked exhibit above will simply be marked Confidential when submitted to IC.
| _ The asterisked items (*) require further justification before permanent confidentiality will be allowed. These also currently 2 _ Please refer to >
require review by the FCC under their Permit-But-Ask policy before the grant is issued and can delay completion of an application. Further justification should be added to the note above. One such example for a potted device would be: The EUT is FULLY potted using a non-removable epoxy based material. Removal of potting material causes irreparable damage to internal circuitry. See photographs exhibits that outline the device before and after potting. for complete details. Versa Networks Inc. V a R S A 6001 America Center Drive. Suite 400 San Jose. CA 95002 www. versa-networks.com Phone (408)-385-766U) Sincerely, ki /Z Me fo 7 KU By: mLUTIAG Nic
(Signhature/Title*) (Print name) iven for applicant on the FCC site fan appropriate
; should be pls
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2020-04-30 | 2402 ~ 2480 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2020-04-30
|
||||
1 | Applicant's complete, legal business name |
Versa Networks
|
||||
1 | FCC Registration Number (FRN) |
0027909407
|
||||
1 | Physical Address |
6001 America Center Dr, 4th floor Suite 400
|
||||
1 |
6001 America Center Dr, 4th floor
|
|||||
1 |
San Jose, CA
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
h******@acbcert.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2ARF9
|
||||
1 | Equipment Product Code |
CSG3X5
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
K**** M******
|
||||
1 | Telephone Number |
+1-40********
|
||||
1 | Fax Number |
+1-40********
|
||||
1 |
k******@versa-networks.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Intertek Testing Services Limited Shanghai
|
||||
1 | Name |
W**** Z****
|
||||
1 | Physical Address |
Building No.86, 1198 Qinzhou Road(North)
|
||||
1 |
Shanghai, 200233
|
|||||
1 |
China
|
|||||
1 | Telephone Number |
86 21********
|
||||
1 | Fax Number |
86 21********
|
||||
1 |
W******@intertek.com
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Cloud Services Gateway | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power Output listed is conducted. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Intertek Testing Services Limited, Shanghai
|
||||
1 | Name |
L******** X********
|
||||
1 | Telephone Number |
+86 2********
|
||||
1 |
l******@intertek.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2402.00000000 | 2480.00000000 | 0.0001000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC