all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 1.44 MiB | July 25 2019 | |||
1 |
|
Confidential Request Letter | Cover Letter(s) | 255.19 KiB | July 25 2019 | |||
1 |
|
External Photos | External Photos | 536.21 KiB | July 25 2019 | |||
1 |
|
Internal Photos | Internal Photos | 343.55 KiB | July 25 2019 | |||
1 |
|
Label Location | ID Label/Location Info | 859.34 KiB | July 25 2019 | |||
1 |
|
Label Location Justification Cover Letter | Cover Letter(s) | 189.44 KiB | July 25 2019 | |||
1 |
|
Label Sample | ID Label/Location Info | 961.56 KiB | July 25 2019 | |||
1 |
|
Power of Attorney Letter | Cover Letter(s) | 193.14 KiB | July 25 2019 | |||
1 |
|
Test Report | Test Report | 1.94 MiB | July 25 2019 | |||
1 |
|
Test Setup Photos | Test Setup Photos | 432.20 KiB | July 25 2019 |
1 | User Manual | Users Manual | 1.44 MiB | July 25 2019 |
Sensor ln'ti lizatio Following pow r-on. Versa otion s.ensor
,s f lly operational a er a one-minute warm-up. ce pet yeaL switch. he tamper the LED by remo\iing If the LEO is OT enabled, N.atr. T e Vel'lia r'lotion should b'!? tested o In ormaf, Operating Mad : Enable depress rotary d"al to a HIGH SEN IT ITV (non-pet Immune) across LOW (pe immune), Wi the sens tivrty set at H GH, the LED shou!d normal before should steps. continLJing remain mode, and re fnsert 1elds,ol the walk teS1. When there is no motion the mon1 ored area ( 1thin the sensor's fter about h,010 to four Each time the LEO turns ON, wal for it to turn OFP. Then. wail 12 seconds turn ON (for Alarm) the bac mounting to en remov the battery. Wm the the LED shou d turn ON (for Ala m) aher about 1hr e o five normal in the monitored With sens1t.i111ty th battery. Walk bracket area, the LED opt1ca 1ew),
,set c1t OFF. I steps. Alarm Processing Dua elemen signal sensitivity allernale fields-o1-view
"' e.xdusively setting,(+, (, +). (. -. ) or(-, , -) ill cause an alarm. even are counted as "pulses detector when polarit be ween (1-) and () polarity. HlghBar-qualif1ed Oep nc1ng oo te,nate .
'
Installation 1. Mo Instruction
:::: 7.5-10 1.Height 2.Clear line-of-sight from sensor 3.Wall lemperature similar 4. Sensor 5.Sensor aimed ay ffom windows aimed away from heaters fee above oor or monitored area. lo monilored area. lo walls/floor of monitored nd reflected cooler outlets Nnre: Glass are-a. sunlight. or healer/
. will block sensor's vi , 1.LED Indicator O peration
, Specifications The belo, chart shows possible LED . VERSA MO ON-X SOIi STA Lm DlSPL.&1'
1'ra:nsn'liD:ll-an R'llft ll Se 40 fee 1ft .>E!MOffatmg direction 40 leet at 45" angle from direction
(Sid Vif\'o' n feet}
sensorfKmQ 1.5
-
OFF aflT)-Up Alarm 0 3-6 Second5. ormal OFF 0 I.Doi( D<r.vn Shi>.: Range:
0 MlodlaP.ang,;
20 10 V Locg Raoge 40
\e! Serial numuers re localed Linder ba e ry. See Fi51ure E. 10 6. state-of-the-art stealth eng neered wl h the orld s bes analog and mater als. Special mic.ro controller-grade The Versa Mo ion is a professional mo f on sensor components clrcui provides detection innovative
-better patented strange so he processor ror alse addi on, than most ASIC-based detection much than conventional detectors, from alse PYROFLEX IR lmrusion signals easily tells ighBar processing real intrusions methods. In alarm rejection provide-s at the lowest inlrLlder cost. The circu, ry includes
-._------,cc_-
-. .r --..... ..!
'--
I - -
------- -
,. 1.5-0 let
,S,muio .,,. ....... , 1/1-ew Pnt.m loi:i view, n IPe1) Long Range iddle Range 44 12 Sho Range Look Do
.. 12 Remove backplate. dial Nith nameaci screwdriver system and sen-sitrvity. See Figure 1o coordina ng secunty See figure B,. Turn compatibility 0 Hone ell f
:Z 2GlG w 1tru.ltivr'
4 olsys / lnt.ertog,1" lowHllllttivit, 5 Qobr., / interlogb:
1 HolllaJt 3 2GIG bigh 0
'lO 30 Compatibility Adjustment 2. 4. 2.Backplate R onl 1---t- - ....._-+...,..., ,..!--- FOV 1eld of vie 1J DSC low 1 DSC
&
0 1----ri ----
12 0 12 a Bosci'I 1ow ,..-m 9 Bosch .mgn Fu:i'rurwL
+
In the slo at the bottom of he mounting the bracket o remove tt from the Versa Motion. bracket, See Fi ur B. use a screwdriver or thumbnail Lo ift up on FigunB. flgure C .-
- ---
Fi unD. 3. Base Hole PTtparation. 1.For wall mounting, 2.For corner knock ou hole covers. wall mourrting, or 45 degree See Figure C. use drill to open at least two holes l base side depressions. 3.For bracket mounting, use dril to open a 3 mm hole in the cen er or the square at recess the rear or th base. 4.all Moun ing Use screws D. to mount on wall or in comer. For wall tamper, screw in hole referred to in Flgur 1th low sensiti1,1ity
(pe nmune), d tect1on occurs n 3 to 5 slt-ps. 1th t, 19h sensitivi y
(non-p l immu e). d tect.io occurs In 2 to 4 s eps. Pe immuni y defi d up to 65 lbs. lhalttir ryUf Dlm1ml,on.s W rnn1y UnJq lDCod PR lmrrnmlty
\hi.:TNt lndicatm um battery (repfacal)le) t6 1 CR123 I, 6--B ye rs [typlcaQ 2.s :it 4.3 x 5 years Milhons Ur:t to 65 lb LEO LED Low battery Strong, Cover & wall tamper 32F (0-Cl 12Z"F FCC, JC Ves reliable
(50"C)
, For UL coffljlliiJflC e 1n units e for res dential on . UlTUr}I Approv,
.SUpitrvisary SJvnal O ng fffll ntuni
1 | Confidential Request Letter | Cover Letter(s) | 255.19 KiB | July 25 2019 |
July 23, 2019 Attention: FCC Reviewing Engineering Reference: Confidentiality Request regarding application for certification of FCC ID: 2AD9XMOTION-X To Whom it May Concern, Request is hereby submitted by Versa Wireless Inc. to withhold permanently from public review certain portions of the application for equipment certification for the referenced Industry Canada identifiers. The following exhibits of the application are to be kept permanently confidential:
Exhibit Type Schematic Diagram File name 03 - 2AD9X-MOTION-X-Schematic - Rev 1-3 02 - 2AD9X-MOTION-X-Block Diagram Rev 1-3 Block Diagram Bill of Materials Operational Description 04 - 2AD9X-MOTION-X-BOM - Rev 1-3 05 - 2AD9X-MOTION-X-Operational Description 05B - 2AD9X-MOTION-X-Duty Cycle Correction factor The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to Versa Wireless Inc and provide unjustified benefits to its competitors. Best Regards, Justin Carlson General Manager Versa Wireless Inc 103 19292 60th Ave. Surrey, BC V3S 3M2 Canada
1 | External Photos | External Photos | 536.21 KiB | July 25 2019 |
Fig 1 : Motion-X Top Side showing Lens and Box Fig 2: Motion-X Bottom Side Plastics and Wall Mount Brace Fig 3 : Motion-X Bottom Side Showing Battery Compartment, Tamper Sw, and Protocol Switch Fig.4 Left Side Fig.4 Right Side Fig.4 Top End View Fig.4 Bottom End View
1 | Internal Photos | Internal Photos | 343.55 KiB | July 25 2019 |
Fig 3 : Motion-X Bottom Side Showing Battery Compartment, Tamper Sw, and Protocol Switch Fig 4: Motion-X Lens Removed, showing PCB Top Side in Plastics with Antenna Fig 5: Motion-X Close up View of PCA Top Side Fig 6: Motion-X Close up View of PCA Bottom Side
1 | Label Location Justification Cover Letter | Cover Letter(s) | 189.44 KiB | July 25 2019 |
Apr 17, 2019 Timco Engineering, Inc. 849 NW State Road 45 P.O. Box 370 Newberry, Florida 32669 Re: Justification for Label Location FCC:
IC:
2AD9XMOTION-X 12637A-MOTIONX To Whom It May Concern:
Per our label location exhibit, we will place our label on the inside of the housing Lid. The underside of the housing is taped to the wall and would not be seen. The outside of the small sensor housing would degrade the appearance of the sensor in the home. The inside of the Lid is easily accessible and visible. Sincerely, Justin Carlson General Manager Versa Wireless Inc. 103 19292 60th Ave. Surrey, BC V3S 3M2 Canada
1 | Label Sample | ID Label/Location Info | 961.56 KiB | July 25 2019 |
_ .....
-
-
- -
,_ -
,
-- --
- -
r
- ,.,
- ,-
-
--
:x.
, .
,-- ._
,-,
-
--
- -
GI
---
,__J 0 -
-
- r-
z
1 | Power of Attorney Letter | Cover Letter(s) | 193.14 KiB | July 25 2019 |
844 20 VERSA 1 604 427 0857 support@versawireless.com www.versawireless.com 103 19292 60th Ave. Surrey, BC V3S 3M2 Date: Apr 15, 2019 Product/Model Number: Motion-X FCC ID: 2AD9XMOTION-X IC: 12637A-MOTIONX To Whom It May Concern:
We, the undersigned, hereby authorize Parminder Singh at Quality Auditing Institute Laboratories Ltd. to act on our behalf on all matters concerning the above named equipment. This shall include the following:
Testing Approval applications and procedures We declare that Quality Auditing Institute Laboratories Ltd. is allowed to forward all information related to the approval project to the applied certification body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out by Quality Auditing Institute Ltd. On our behalf shall have the same effect as acts of our own. Regards, Justin Carlson General Manager Email: Justin@VersaWirelessInc Ph 844 208 3772 On belhalf of: Versa Wireless Inc.
1 | Test Report | Test Report | 1.94 MiB | July 25 2019 |
ELECTROMAGNETIC COMPATIBILITY TEST REPORT PREPARED FOR VERSA WIRELESS INC BY QAI LABORATORIES QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada E10676-1804_ Versa Wireless-PIR-MultiP_Rev1.1 46 April 17, 2018 QAI Laboratories Inc. 3980 North Fraser Way, Burnaby, BC, V5J 5K5 Canada
(604) 527-8378
(604) 527-8368 Report Reference Number:
Total Number of Pages:
Date of Issue:
EMC Test Laboratory:
Address:
Phone:
Fax:
Laboratory Accreditations (per ISO/IEC 17025:2005):
American Association for Laboratory Accreditation Certificate Number: 3657.02 This report has been completed in accordance with the requirements of ISO/IEC xxxx5. Test results contained in this report are within QAI Laboratories ISO/IEC xxxx5 accreditation. QAI Laboratories authorizes the applicant to reproduce this report, provided it is reproduced in its entirety and for the use by the companys employees only. EMC Client:
Address:
Phone:
Versa Wireless Inc 103 19292 60th Ave. Surrey, BC V3S 3M2, Canada 778 772 0623 Applicable Test Standards:
FCC Title 47 CFR Part 15: Subpart C 15.231 FCC Title 47 CFR Part 15: Subpart B, ICES-003 Issue 6 Unit Under Tested:
Model Number:
FCC ID:
IC Certification Number:
Manufacturer:
ICES-003 Issue 6 RSS-210 Issue 9 RSS-Gen Issue 4 Versa Motion Family Motion-X 2AD9XMOTION-X 12673A-MOTIONX Versa Wireless, Inc. QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada REVISION HISTORY Date Report Number Rev #
Details Authors Initials April 17, 2019 E10676-1804_ Versa-PIR-MultiP 1.1 Initial Release Sept 30, 2018 E10676-1804_ Versa-PIR-MultiP 1.0 Initial Release Sept 24, 2018 E10676-1804_ Versa-PIR-MultiP 0.0 Draft JQ JQ JQ All previous versions of this report have been superseded by the latest dated revision as listed in the above table. Please dispose of all previous electronic and paper printed revisions accordingly. Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 2 of 46 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada REPORT AUTHORIZATION The data documented in this report is for the test equipment provided by Versa Wireless Inc. The tests were conducted on the sample equipment as requested by Versa Wireless Inc for the purpose of demonstrating compliance with FCC Title 47 CFR Part 15: Subpart C, 15.231, RSS-210 Issue 9, and RSS-Gen Issue 4 as agreed upon by Versa Wireless Inc as per Quote 18AN07235. Versa Wireless Inc is responsible for the tested product configuration, continued product compliance, and for the appropriate auditing of subsequent products as required. This report may comprise partial list of tests that are required for FCC or IC Declaration of Conformity and can only be produced by the manufacturer. This is to certify that the following report is true and correct to the best of our knowledge. Tested by Jack Qin EMC Division Project Manager Report Prepared by Raksha Rawat EMC Technical Writer Approved by Parminder Singh Director for the EMC Department Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 3 of 46 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada QAI FACILITIES Founded in 1994 by a group of experienced certification and testing experts, QAI is an independent third-party testing, inspection and certification organization which serves the building industry, government and individuals with cost effective solutions through our in-
house capabilities / services, and an established world-wide network of qualified affiliates. To help get your product to market, trust the provider that many leading global manufacturers do: QAI. British Columbia QAI Laboratories Inc. Main Laboratory/Headquarters 3980 North Fraser Way, Burnaby, BC V5J Canada California Ontario QAI Laboratories Inc. 1081 Meyerside Drive, Unit #14 Mississauga, ON L5T 1M4 Canada Virginia QAI Laboratories Ltd. 1047 Zachary Taylor Hwy, Suite A Huntly, VA 22640 USA Oklahoma QAI Laboratories Ltd. 8385 White Oak Avenue Rancho Cucamonga, CA 91730 USA QAI Laboratories Ltd. 108th East Avenue, Tulsa, OK 74116 USA QAI EMC ACCREDITATION QAI EMC is your one-stop regulatory compliance partner for electromagnetic compatibility (EMC) and electromagnetic interference
(EMI). Products are tested to the latest and applicable EMC/EMI requirements for domestic and international markets. QAI EMC goes above and beyond being a testing facilitywe are your regulatory compliance partner. QAI EMC has the capability to perform RF Emissions and Immunity for all types of electronics manufacturing including Industrial, Scientific, Medical, Information Technology, Telecom, Wireless, Automotive, Marine and Avionics. EMC Laboratory Location FCC Designation (3m SAC) IC Registration (3m SAC) A2LA Certificate Burnaby, BC, Canada CA9543 21146-1 3657.02 Headquarters & EMC Laboratory in Burnaby, BC Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 4 of 46 TABLE OF CONTENTS QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada 2.1 1.2 1.3 1.4 REVISION HISTORY .......................................................................................................................................................................... 2 REPORT AUTHORIZATION .............................................................................................................................................................. 3 QAI FACILITIES .................................................................................................................................................................................. 4 QAI EMC ACCREDITATION ............................................................................................................................................................. 4 TABLE OF CONTENTS ...................................................................................................................................................................... 5 Section I: EXECUTIVE SUMMARY ....................................................................................................................................................... 6 Purpose...................................................................................................................................................................................... 6 Scope ......................................................................................................................................................................................... 6 Summary of Results .................................................................................................................................................................. 6 Section II: EQUIPMENT UNDER TEST (EUT) INFORMATION ......................................................................................................... 7 Product Description .................................................................................................................................................................. 7 GENERAL INFORMATION .................................................................................................................................................................... 8 3.1 Environmental Conditions ........................................................................................................................................................ 8 3.2 Measurement Uncertainty ......................................................................................................................................................... 8 3.3 Worst Test Case ........................................................................................................................................................................ 8 Sample Calculations of Emissions Data.................................................................................................................................... 9 3.4 3.5 Test Equipment List ................................................................................................................................................................ 10 Section III: TEST RESULTS ................................................................................................................................................................... 11 Antenna Requirement ............................................................................................................................................................. 11 Transmission Time .................................................................................................................................................................. 12 Field Strength of Carrier Frequency ....................................................................................................................................... 15 Intentional Spurious Emissions ............................................................................................................................................... 16 Duty Cycle Correction Factor Calculation .............................................................................................................................. 24 20 dB Occupied Bandwidth .................................................................................................................................................... 33 99% Occupied Bandwidth ...................................................................................................................................................... 37 Receiver Radiated Emissions .................................................................................................................................................. 41 Appendix A: TEST SETUP PHOTOS ..................................................................................................................................................... 43 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 5 of 46 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada Section I: EXECUTIVE SUMMARY 1.2 Purpose The purpose of this report is to demonstrate and document the compliance of PIR MultiP as per Sections 1.2 &
1.3 of this report. 1.3 Scope The information documented in this report is based on the test methods and levels as per Quote 18AN07235:
- FCC Title 47 CFR Part 15 Radio Frequency Devices, Subpart B- Unintentional Radiators.
-
ICES-003 Issue 6 Information Technology Equipment (Including Digital Apparatus) Limits and methods of measurement.
- FCC Title 47 CFR Part 15 Radio Frequency Devices, Subpart C Intentional Radiators o 15.231 Periodic Operation in the band 40.66-40.70 MHz and above 70 MHz
- RSS-210 Issue 9 License-exempt Radio Apparatus (All Frequency Bands): Category I Equipment o Annex 1 Momentarily Operated Devices and Remote Control
- RSS-Gen Issue 4 General Requirements and Information for the Certification of Radio Apparatus 1.4 Summary of Results The following tests demonstrate the testimony to FCC and IC Mark Electromagnetic compatibility radio testing for the PIR MultiP device manufactured by Versa Wireless Inc. The following testing was performed pursuant to FCC & IC Radio and RF Emissions Standards Test Description Antenna Requirement Transmission Time Field Strength of Carrier Frequency Applicable FCC Test Standard Applicable IC Test Standard Title 47 CFR Part 15: Subpart C 15.203 Rss-Gen Issue 4 Section 7.1.2 Title 47 CFR Part 15: Subpart C RSS-210 Issue 9 15.231 (a) Title 47 CFR Part 15: Subpart C 15.231 (b) RSS-210 Issue 9 RSS-Gen Issue 4 RSS-210 Issue 9 RSS-Gen Issue 4 Test Method Result N/A N/A Pass Pass ANSI C63.10-2013 Pass ANSI C63.10-2013 Pass Intentional Spurious Title 47 CFR Part 15: Subpart C Emissions 15.231 (b) Duty Cycle Title 47 CFR Part 15: Subpart C Rss-Gen Issue 4 ANSI C63.10-2013 Pass Title 47 CFR Part 15: Subpart C 15.231 (c) N/A ANSI C63.10-2013 Pass N/A N/A RSS-210 Issue 9 RSS-Gen Issue 4 ANSI C63.10-2013 Pass RSS-Gen Issue 4 ANSI C63.4-2014 Pass 20dB Occupied Bandwidth 99% Occupied Bandwidth Receiver Radiated Emissions Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 6 of 46 Section II: EQUIPMENT UNDER TEST (EUT) INFORMATION 2.1 Product Description The information provided in this section is for the Equipment Under Test (EUT) and the corresponding Auxiliary Equipment needed to perform the tests as a complete system. QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada EUT Motion-X (PIR-MultiP) Unit Under Tested:
Model Number:
FCC ID:
IC Certification Number:
Equipment Under Test (EUT) Information Versa Motion Family Motion-X / PIR-MultiP 2AD9XMOTION-X 12673A-MOTIONX EUT Description FCC ID IC Number Manufacturer Model No. Serial No. Motion-X (PIR-MultiP) Versa Motion Multiprotocol Device 2AD9XMOTION-X 12673A-MOTIONX Versa Wireless, Inc. Motion-X or PIR-MultiP 0000010 Operating Frequency 319.5MHz, 344.92MHz, 345MHz, 433.42MHz, 433.92MHz. Transmit Power Antenna Type Antenna Gain Input Power 0.01 Watts Monopole Whip 3 dBi 1 x CR123A, Lithium Battery, 3VDC, replaceable Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 7 of 46 GENERAL INFORMATION 3.1 Environmental Conditions The equipment under test was operated and tested under the following environmental conditions:
QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada Parameter Location Temperature Relative Humidity 3.2 Measurement Uncertainty Parameter Radiated Emissions, 30MHz-1GHz Radiated Emissions, 1GHz-40GHz Radio Frequency Total RF Power Conducted Spurious Emissions, Conducted RF Power Density, Conducted Temperature Humidity DC and low frequency voltages 3.3 Worst Test Case Conditions Indoors 22-28C 39.7 - 54.4%
Uncertainty 2.40 dB 2.48 dB 1.5 x 10-5 MHz 1.36 dB 1.36 dB 1.36 dB 1C 5 %
3 %
Worst-case orientation was determined during the preliminary testing. The final radiated emissions were performed in the worst-case orientation. Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 8 of 46 3.4 Sample Calculations of Emissions Data QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada Radiated and conducted emissions were performed using EMC32 software developed by Rohdes & Schwarz. Transducer factors like Antenna factors, Cable Losses and Amplifier gains were stored in the test templates which are used to perform the emissions measurements. After test is finished, data is generated from the EMC32 consisting of product details, emission plots and final data tables as shown below. Frequency Q-Peak
(MHz)
(dBV/m) Meas. Time
(ms) Bandwidth
(kHz) Ant. Ht.
(cm) Turntable position Pol 42.663900 33.0 1000.000 120.000 100.0 H Corr.
(dB) Margin Limit
(dB)
(dBV/m) 13.2 7.5 40.5
(deg) 70.0 Quasi Peak reading shown in the table above is already corrected by the software using correction factor shown in column Corr. The correction factor listed under Corr. table calculated as:
Corr.(dB) = Antenna factor + Cable loss Or Corr. (dB) = Antenna factor + Cable Loss - Amp gain (if pre-amplifier was used) The final Quasi-peak reading shown in the data is calculated by the software using following equation:
Corrected Quasi Peak (dBV/m) = Raw Quasi-Peak Reading + Antenna factor + Cable loss To obtain the final Quasi-Peak or Average reading during power line conducted emissions, transducer factors are included in the final measurement as shown below. Frequency
(MHz) 0.150 Q-Peak
(dBV) 44.3 Meas. Time Bandwidth
(ms) 1000.000
(kHz) 9.000 PE Corr.
(dB) GND 0.6 Margin
(dB) 21.7 Limit
(dBV) 66.0 Frequency
(MHz) 0.150 Average
(dBV)
(ms) Meas. Time Bandwidth
(kHz) 9.000 PE Corr.
(dB) GND 0.6 Margin
(dB) 28.8 Limit
(dBV) 56.0 27.2 1000.000 Quasi-Peak or Average reading shown in above table is already corrected by the software using the correction factor shown in column Corr. The correction factor listed under Corr. table calculated as:
Corr.(dB) = Antenna factor + Cable loss The final Quasi-peak or Average reading shown in the data is calculated by the software using following equation:
Corr. Quasi-Peak/Average Reading (dBV) = Raw Quasi Peak/Average Reading + Antenna factor + Cable loss The allowable margins from the limits, as per the standards, were calculated for both radiated and conducted emissions:
Margin (dB) = Limit Quasi-Peak or Average reading Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 9 of 46 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada 3.5 Test Equipment List The tables below contain all the equipment used by QAI Laboratories in conducting all tests on the Equipment Under Test (EUT) as per Section 1.3. Emissions Test Equipment Manufacturer Sunol Sciences Sunol Sciences EMCO Sunol Sciences Model SM46C TWR95 6502 JB3 Sunol Sciences DRH-118 ETS Lindgren ETS Lindgren 2165 2125 Description Serial No. Calibration Due Date Turntable Mast 051204-2 TREML0001 N/A N/A Loop Antenna 2016 2020-Nov-13 Biconilog Antenna 30MHz 3GHz Horn Antenna 1GHz-18GHz Turntable Mast A120106 2020-Sep-24 A050905 2019-Mar-10 00043677 00077487 N/A N/A Rohde & Schwarz ESU40 EMI Receiver 100011 2018-Sep-20 Fischer FCC-LISN-50-25-2-08 LISN
(150kHz-30MHz) 2041 2018-Nov-19 ETS Lindgren S201 5-meter Semi-Anechoic Chamber 1030 N/A AH Systems PAM118 Amplifier 10KHz-18GHz 189 Conditional Use Note: Equipment listed above have 3 years calibration interval. The following components and equipment are calibrated as a complete signal path. Manufacturer Model Description Serial No. Calibration Calibration Date Due Date AH Systems PAM118 Amplifier 10KHz-18GHz Insulated Wire Inc. SPS-1753-1140-SPS Yellow cable, 3m Insulated Wire Inc. SPS-1753-2400-SPS Yellow cable, 6m WEINSCHEL ENGINEERING 44 6db attenuator A.H.Systems PAM-1840VH Preamplifier 18-40GHz A.H.Systems 2649-03 Green short input cable A.H.Systems 2649-225 Green short output cable 189 102395 091096 665 152 395 396 December 31, 2018 December 31, 2019 December 31, 2018 December 31, 2019 Measurement Software List Manufacturer Rhode & Schwarz Model EMC 32 Version Description 6.20.0 Emissions Test Software Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 10 of 46 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada Section III: TEST RESULTS 4.1 Antenna Requirement Date Performed:
September 21, 2018 Test Standard:
FCC 47 CFR Part 15.203 and IC Rss-Gen Issue 4 Section 7.1.2 Applicable Regulation:
The purpose of this requirement is to make certain that no other antenna, except for that provided by the responsible party, shall be used with the Equipment-Under-Test (EUT) as defined in FCC CFR 47 Part 15.203 & RSS-Gen Issue 4:
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this Section. The manufacturer may design the unit so that the user can replace a broken antenna, but the use of a standard antenna jack or electrical connector is prohibited. the installer shall be responsible for ensuring that the proper antenna is employed so that the limits in this Part are not exceeded. Modifications:
No modification was required to comply for this test. Result:
An integrated antenna is used on this product and it is not field replaceable. Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 11 of 46 4.2 Transmission Time QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada Date Performed:
August 20, 2018 Test Standard:
Title 47 CFR Part 15: Subpart C, 15.231 (a) o o RSS-210 Issue 9, A.1.1 Requirement(s):
o A manually operated transmitter shall be equipped with a push-to-operate switch and be under manual control at all times during transmission. When released, the transmitter shall cease transmission within no more than 5 seconds of being released. o A transmitter that has been activated automatically shall cease transmission within 5 seconds of activation. Result:
The EUT complies with the applicable standard. Data & Plot:
Transmission Time, 319.5MHz Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 12 of 46 Ref 30 dBmAtt 60 dB A Center 319.5 MHz5 s/RBW 1 MHzVBW 3 MHzSWT 50 s*3DB*1 PKVIEW-70-60-50-40-30-20-1001020301Marker 1 [T1 ] -3.54 dBm 8.000000 s Date: 20.AUG.2018 20:42:19 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada Transmission Time, 344.92MHz Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 13 of 46 Transmission Time, 345MHz Ref 30 dBmAtt 60 dB A TRG*1 PKCLRWRCenter 344.92 MHz5 s/3DBRBW 1 MHzVBW 3 MHzSWT 50 s-70-60-50-40-30-20-1001020301Marker 1 [T1 ] -23.95 dBm 8.000000 s TRG -15.2 dBmDate: 20.AUG.2018 20:36:57Ref 30 dBmAtt 60 dB A Center 345 MHz5 s/3DBRBW 1 MHzVBW 3 MHzSWT 50 s*1 PKVIEW-70-60-50-40-30-20-1001020301Marker 1 [T1 ] -24.37 dBm 8.000000 s Date: 20.AUG.2018 20:39:47 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada Transmission Time, 433.42MHz Transmission Time, 433.92MHz Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 14 of 46 Ref 30 dBmAtt 60 dB A TRG RBW 1 MHzVBW 3 MHz*1 PKCLRWR3DBCenter 433.92 MHz5 s/SWT 50 s-70-60-50-40-30-20-1001020301Marker 1 [T1 ] -23.86 dBm 8.000000 s TRG -15.2 dBmDate: 20.AUG.2018 20:32:32 4.3 Field Strength of Carrier Frequency QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada Date Performed:
August 9, 2018 Test Standard:
Title 47 CFR Part 15: Subpart C, 15.231 (b) o o RSS-210 Issue 9, A.1.2 o RSS-Gen Issue 4, 8.9 & 8.10 Test Method:
o ANSI C63.10-2013 Required Limit(s):
The field strength of emissions from intentional radiators operated under this section (15.231) shall not exceed the following:
Fundamental Frequency, f
(MHz) 40.66 40.70 70 130 130 174 174 260 260 470 above 470 Field strength of Fundamental
(V/m) 2250 1250 1250 3750*
3750 3750 12500*
12500 Field strength of Fundamental
(dBV/m) 67.0 62.0 62.0 71.5*
71.5 71.5 82.0*
82.0
* - Linear interpolation with frequency, f, in MHz:
For 130-174 MHz: Field Strength (V/m) = (56.82 x f) 6136 For 260-470 MHz: Field Strength (V/m) = (41.67 x f) 7083 Note 1: The above field strength limits are specified at a distance of 3 meters. The tighter limits apply at the band edges. Data & Plot:
Freq. Raw Peak Ant. System Corr AF Corrected Peak 319.5 MHz dBuV 66.5 68.5 68.2 60.3 57.1 71.4 71 71 70.5 70.5 433.42 433.92 344.94 345 V H V H V H H H H H dB 8.4 8.4 8.4 8.4 8.4 8.4 8.6 8.6 8.9 8.9 dB/m dBuV/m 13.8 13.8 13.8 13.8 13.8 13.8 14.2 14.2 16.5 16.5 88.7 90.7 90.4 82.5 79.3 93.6 93.8 93.8 95.9 95.9 Result: The EUT complies with the applicable standard. Duty Cycle Corr dB 21.3 21.3 21.3 21.3 21.3 21.3 21.5 22.1 22.5 20.9 Avg FS Limit Avg Margin EUT Orientation dBuV/m dBuV/m 67.4 69.4 69.1 61.2 58 72.3 72.3 71.7 73.4 75 75.9 75.9 75.9 75.9 75.9 75.9 77.3 77.3 80.8 80.8 dB 8.5 6.5 6.8 14.7 17.9 3.6 5.0 5.6 7.4 5.8 V H Flat Flat Flat Flat Flat Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 15 of 46 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada 4.4 Intentional Spurious Emissions Date Performed:
August 10, 2018 Test Standard:
Title 47 CFR Part 15: Subpart C, 15.231 (b) o o RSS-210 Issue 9, A.1.2 o RSS-Gen Issue 4, 8.9 & 8.10 Test Method:
o ANSI C63.10-2013 Required Limit(s):
Fundamental Frequency, f
(MHz) 40.66 40.70 70 130 130 174 174 260 260 470 above 470 Field strength of Field strength of Fundamental
(V/m) Fundamental
(dBV/m) 2250 1250 1250 3750*
3750 3750 12500*
12500 67.0 62.0 62.0 71.5*
71.5 71.5 82.0*
82.0 Field strength of Field strength of Spurious Emissions
(V/m) 225 125 125 375*
375 375 1250*
1250 Spurious Emissions
(dBV/m) 47.0 62.0 42.0 51.5*
51.5 51.5 62.0*
62.0
* -
Linear interpolation with frequency, f, in MHz:
For 130-174 MHz: Field Strength (V/m) = (56.82 x f) 6136 For 260-470 MHz: Field Strength (V/m) = (41.67 x f) 7083 Note 1: The above field strength limits are specified at a distance of 3 meters. The tighter limits apply at the band edges. The limits on the field strength of the spurious emissions in the above table are based on the fundamental frequency of the intentional radiator. Spurious emissions shall be attenuated to the average (or, alternatively, CISPR quasi-peak) limits shown in this table or to the general limits shown in 15.209, whichever limit permits a higher field strength. Frequency, f
(MHz) 0.009 0.490 0.490 1.705 1.705 30.0 30 88 88 216 216 960 above 960 Field strength
(dBV/m)
(20*log(2400/f (kHz))) + 40 dB
(20*log(24000/f (kHz))) + 20 dB 49.5 40.0 43.5 46.0 54.0 Note 1: The above field strength limits are specified at a distance of 3 meters. The tighter limits apply at the band edges. Note 2: The emissions limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9-90 kHz, 110-490 kHz and above 1000 MHz. Radiated emission limits in these three bands are based on measurements employing an average detector. Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 16 of 46 Unwanted emissions that fall into the restricted bands specified on the table below shall comply with the limits specified on the table limits above as per 15.209 and Clause 8.9 of RSS-Gen. FCC Restricted Bands:
QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada IC/RSS Restricted Bands:
Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 17 of 46 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada Method of Measurement:
The EUT was tested in our 3 m SAC and was positioned on the center of the turntable. The transmitter was set for continuous transmission. The operating frequency of the device was measured for all radiated emissions 10 kHz to 4 GHz up to the 10th harmonic of the highest fundamental frequency. The EUT was pre-scanned in 3 different orthogonal orientations and was found to radiate highest when placed flat on the table top as indicated in the test photos. Modifications:
No modification was required to comply for this test. Result:
The intentional spurious emissions signals at frequency range 9 kHz to 30 MHz were 20 dB below the required limit therefore need not necessary to include in the report (15.31(o)). The EUT complies with the applicable standard. Data & Plot:
Radiated Emissions (150 kHz-30MHz) scanned at 3m SAC Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 18 of 46 Level in dBV/m QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada Radiated Emissions (30MHz-1GHz) scanned at 3m SAC Radiated Emissions (1GHz-5GHz) scanned at 3m SAC Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 19 of 46 Level in dBV/mLevel in dBV/m QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada Measurement Data of Spurious Emissions Carrier Frequency 2 3 4 Freq. MHz 639 958.5 1278 5 1597.5 6 1917 7 2236.5 8 2556 9 2875.5 10 3195 Raw Peak dBuV 76.2 84.6 55.9 65.9 56 56 62 63 60 58 56 61 54 55 50 51 51 51 System dB dB 28.6 28.6 29.3 29.3 33.5 33.5 31.79 31.79 31 31 29.5 29.5 29.6 29.6 28.84 28.84 28.2 28.2 Antenna Factor 19.6 19.6 23 23 28.7 28.7 28.7 28.7 31.6 31.6 32.2 32.2 32.7 32.7 32.8 32.8 32.9 32.9 Ave Ant. V H V H V H V H V H V H V H V H V H 75.8 84.2 54.2 64.7 52 53 61 61 58 55 53 58 46 49 42 44 42 42 319.5 MHz DCC. Factor Corrected Peak Avg FS Limit Avg Margin dBuV/m dB dBuV/m dBuV/m 67.2 75.6 49.6 59.6 51.2 51.2 58.91 59.91 60.6 58.6 58.7 63.7 57.1 58.1 53.96 54.96 55.7 55.7
-21.3
-21.3
-21.3
-21.3
-21.3
-21.3
-21.3
-21.3
-21.3
-21.3
-21.3
-21.3
-21.3
-21.3
-21.3
-21.3
-21.3
-21.3 45.9 54.3 28.3 38.3 29.9 29.9 37.61 38.61 39.3 37.3 37.4 42.4 35.8 36.8 32.66 33.66 34.4 34.4 55.9 55.9 55.9 55.9 54 54 54 54 55.9 55.9 54 54 55.9 55.9 54 54 55.9 55.9 dB 10 1.6 27.6 17.6 24.1 24.1 16.39 15.39 16.6 18.6 16.6 11.6 20.1 19.1 21.34 20.34 21.5 21.5 Restricted Band Restricted Band Restricted Band Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 20 of 46 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada Carrier Frequency Freq. Raw Peak Ave Ant. MHz dBuV 2 689.88 3 1034.82 4 1379.76 5 1724.7 6 2069.64 7 2414.58 8 2759.52 76.7 86.1 53.6 55 59 58 60 57 55 55 51 51 50 53 76.3 85.1 47 50 56 55 58 54 50 50 44 45 40 47 System dB dB 28.6 28.6 35.3 35.3 33.5 33.5 31.5 31.5 31 31 29.6 29.6 28.84 28.84 V H V H V H V H V H V H V H Carrier Frequency Raw Peak dBuV Freq. MHz Ave Ant. 2 3 4 5 6 7 8 690 1035 1380 1725 2070 2415 2760 76.6 76.2 86 53 56 57 59 60 60 55 56 50 51 51 54 85.4 47 52 54 57 58 58 52 52 45 44 41 47 V H V H V H V H V H V H V H System dB dB 28.6 28.6 35.3 35.3 33.5 33.5 31.5 31.5 31 31 29.6 29.6 28.84 28.84 Antenna Factor 20.1 20.1 28.5 28.5 28.7 28.7 29.9 29.9 31.6 31.6 32.6 32.6 32.8 32.8 344.92 MHz Antenna Factor Corrected Peak DCC. Factor Avg FS Limit Avg Margin 20.1 20.1 28.5 28.5 28.7 28.7 29.9 29.9 31.6 31.6 32.6 32.6 32.8 32.8 dBuV/m dB dBuV/m dBuV/m 68.2 77.6 46.8 48.2 54.2 53.2 58.4 55.4 55.6 55.6 54 54 53.96 56.96
-21.5
-21.5
-21.5
-21.5
-21.5
-21.5
-21.5
-21.5
-21.5
-21.5
-21.5
-21.5
-21.5
-21.5 46.7 56.1 25.3 26.7 32.7 31.7 36.9 33.9 34.1 34.1 32.5 32.5 32.46 35.46 57.3 57.3 54 54 54 54 57.3 57.3 57.3 57.3 57.3 57.3 54 54 345 MHz DCC. Factor Corrected Peak Avg FS Limit Avg Margin dBuV/m dB dBuV/m dBuV/m 68.1 77.5 46.2 49.2 52.2 54.2 58.4 58.4 55.6 56.6 53 54 54.96 57.96
-22.1
-22.1
-22.1
-22.1
-22.1
-22.1
-22.1
-22.1
-22.1
-22.1
-22.1
-22.1
-22.1
-22.1 46 55.4 24.1 27.1 30.1 32.1 36.3 36.3 33.5 34.5 30.9 31.9 32.86 35.86 57.3 57.3 54 54 54 54 57.3 57.3 57.3 57.3 57.3 57.3 54 54 21.54 18.54 Restricted Band Restricted Band Restricted Band dB 10.6 1.2 28.7 27.3 21.3 22.3 20.4 23.4 23.2 23.2 24.8 24.8 dB 11.3 1.9 29.9 26.9 23.9 21.9 21 21 23.8 22.8 26.4 25.4 21.14 18.14 Restricted Band Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 21 of 46 Carrier Frequency 433.42 MHz QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada Ave Ant. Raw Peak dBuV 75 72 83.8 80.8 68 79 57 57 61 62 50 51 50 52 51 51 47 49 48 47 67 78 54 55 60 60 41 44 42 46 41 39 35 40 40 35 2 3 4 5 6 7 8 9 Freq. MHz 866.84 1300.26 1733.68 2167.1 2600.52 3033.94 3467.36 3900.78 10 4334.2 System dB dB 29 29 33.5 33.5 31.5 31.5 30.5 30.5 29.6 29.6 28.2 28.2 27.1 27.1 26 26 24.5 24.5 Antenna Factor Corrected Peak DCC. Factor Avg FS Limit Avg Margin dBuV/m dB dBuV/m dBuV/m dB 21.7 21.7 28.7 28.7 29.9 29.9 31.7 31.7 32.7 32.7 32.9 32.9 32.9 32.9 33.3 33.3 33.4 33.4 67.7 76.5 63.2 74.2 55.4 55.4 62.2 63.2 53.1 54.1 54.7 56.7 56.8 56.8 54.3 56.3 56.9 55.9
-22.5
-22.5
-22.5
-22.5
-22.5
-22.5
-22.5
-22.5
-22.5
-22.5
-22.5
-22.5
-22.5
-22.5
-22.5
-22.5
-22.5
-22.5 45.2 54 40.7 51.7 32.9 32.9 39.7 40.7 30.6 31.6 32.2 34.2 34.3 34.3 31.8 33.8 34.4 33.4 60.8 60.8 54 54 60.8 60.8 60.8 60.8 60.8 60.8 60.8 60.8 60.8 60.8 54 54 54 54 15.6 6.8 13.3 2.3 27.9 27.9 21.1 20.1 30.2 29.2 28.6 26.6 26.5 26.5 22.2 20.2 19.6 20.6 V H V H V H V H V H V H V H V H V H Carrier Frequency 433.92 MHz 2 3 4 5 6 7 Freq. Raw Peak Ave Ant. MHz dBuV 867.84 1301.76 1735.68 2169.6 2603.52 3037.44 73.3 86.8 69 79.5 57 57 61 62 50 51 50 52 70.6 83.9 68 79 54 55 60 60 41 44 42 46 V H V H V H V H V H V H System dB dB 29 29 33.5 33.5 31.5 31.5 30.5 30.5 29.6 29.6 28.2 28.2 Antenna Factor Corrected Peak DCC. Factor Avg FS Limit Avg Margin dBuV/m dB dBuV/m dBuV/m dB 21.7 21.7 28.7 28.7 29.9 29.9 31.7 31.7 32.7 32.7 32.9 32.9 66 79.5 64.2 74.7 55.4 55.4 62.2 63.2 53.1 54.1 54.7 56.7
-20.9
-20.9
-20.9
-20.9
-20.9
-20.9
-20.9
-20.9
-20.9
-20.9
-20.9
-20.9 45.1 58.6 43.3 53.8 34.5 34.5 41.3 42.3 32.2 33.2 33.8 35.8 60.8 60.8 54 54 60.8 60.8 60.8 60.8 60.8 60.8 60.8 60.8 15.7 2.2 10.7 0.2 26.3 26.3 19.5 18.5 28.6 27.6 27 25 Restricted Band Restricted Band Restricted Band Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 22 of 46 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada V H V H V H 27.1 27.1 26 26 24.5 24.5 32.9 32.9 33.3 33.3 33.4 33.4 56.8 56.8 54.3 56.3 56.9 55.9
-20.9
-20.9
-20.9
-20.9
-20.9
-20.9 35.9 35.9 33.4 35.4 36 35 60.8 60.8 54 54 54 54 24.9 24.9 20.6 18.6 18 19 Restricted Band 8 9 3471.36 3905.28 10 4339.2 51 51 47 49 48 47 41 39 35 40 40 35 Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 23 of 46 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada 4.5 Duty Cycle Correction Factor Calculation Date Performed:
August 17, 2018 Requirement(s):
o 15.35(c) - Unless otherwise specified, e.g. 15.255(b), when the radiated emission limits are expressed in terms of the average value of the emission, and pulsed operation is employed, the measurement field strength shall be determined by averaging over one complete pulse train, including blanking intervals, as long as the pulse train does not exceed 0.1 seconds. As an alternative (provided the transmitter operates for longer than 0.1 seconds) or in cases where the pulse train exceeds 0.1 seconds, the measured field strength shall be determined from the average absolute voltage during a 0.1 second interval during which the field strength is at its maximum value. The exact method of calculating the average field strength shall be submitted with any application for certification or shall be retained in the measurement data file for equipment subject to notification or verification. Method of Measurement: As called in the ANSI C63.10-2013 standard. Data & Plot:
Data, Duty Cycle Correction Factor Carrier frequency Transmissions Burst Duration Long Pulse Long Pulse Mid pulse Mid pulse Short pulse Short pulse Total Transmissions Duration number Duration number Duration number Duration MHz 319.5 344.94 345 433.42 433.92 ms 18.4 17.2 17 15.8 25.2 ms 1.184 0.272 0.256 0.2 2.512 1 8 12 17 1 1 ms 0.48
`
ms 0.12 0.136 0.12 0.096 0.24 58 46 40 43 27 ms 8.624 8.432 7.872 7.528 8.992 Duty Cycle Correction factor dB
-21.3
-21.5
-22.1
-22.5
-20.9 Transmissions Burst Duration In 100 ms, 319.5 MHz Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 24 of 46 Ref 30 dBmAtt 60 dB A 3DBRBW 3 MHzVBW 10 MHzCenter 319.5052 MHz10 ms/SWT 100 ms TRGVIEW*1 PK-70-60-50-40-30-20-1001020301Marker 1 [T1 ] -4.54 dBm -4.783619 as 2Delta 2 [T1 ] 0.34 dB 18.400000 ms TRG -12.5 dBmDate: 17.AUG.2018 20:53:50 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada Pulse Number, 319.5MHz Pulse Time, 319.5MHz Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 25 of 46 Ref 30 dBmAtt 60 dB A RBW 3 MHzVBW 10 MHz 3DBTRGCenter 319.5052 MHz2 ms/SWT 20 msVIEW*1 PK-70-60-50-40-30-20-1001020301Marker 1 [T1 ] -5.88 dBm 0.000000 s 2Delta 2 [T1 ] -0.27 dB 18.240000 ms TRG -12.5 dBmDate: 17.AUG.2018 21:27:43Ref 30 dBmAtt 60 dB A RBW 3 MHzVBW 10 MHzCenter 319.5052 MHz400 s/SWT 4 ms3DBTRG *VIEW*1 PK-70-60-50-40-30-20-1001020301Marker 1 [T1 ] -6.37 dBm 21.691984 zs 2Delta 2 [T1 ] 0.24 dB 1.104000 ms 3Delta 3 [T1 ] 0.12 dB 1.224000 ms 4Delta 4 [T1 ] 0.46 dB 1.344000 ms TRG -12.5 dBmDate: 17.AUG.2018 21:30:40 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada Mid Pulse Time, 319.5MHz Transmissions Burst Duration In 100 ms, 344.92MHz Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 26 of 46 Ref 30 dBmAtt 60 dB A RBW 3 MHzVBW 10 MHz 3DBTRGCenter 319.5052 MHz400 s/SWT 4 msVIEW*1 PK-70-60-50-40-30-20-1001020301Marker 1 [T1 ] -6.25 dBm 16.480000 ms 2Delta 2 [T1 ] -0.12 dB 480.000000 s TRG -12.5 dBmDate: 17.AUG.2018 21:34:08Ref 30 dBmAtt 60 dB A RBW 3 MHzVBW 10 MHzCenter 344.946 MHz10 ms/SWT 100 ms3DBSGLTRG VIEW*1 PK-70-60-50-40-30-20-1001020301Marker 1 [T1 ] -0.76 dBm -100.000000 s 2Delta 2 [T1 ] 0.00 dB 17.200000 ms TRG -13.9 dBmDate: 17.AUG.2018 20:24:32 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada Pulse Number, 344.92MHz Pulse Time, 344.92MHz Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 27 of 46 Ref 30 dBmAtt 60 dB A RBW 3 MHzVBW 10 MHz3DB TRGCenter 344.946 MHz2 ms/SWT 20 msVIEW*1 PK-70-60-50-40-30-20-1001020301Marker 1 [T1 ] -0.88 dBm 20.000000 s 2Delta 2 [T1 ] -0.52 dB 17.180000 ms TRG -12.5 dBmDate: 17.AUG.2018 20:29:17Ref 30 dBmAtt 60 dB A RBW 3 MHzVBW 10 MHz3DBCenter 344.946 MHz400 s/SWT 4 ms TRGVIEW*1 PK-70-60-50-40-30-20-1001020301Marker 1 [T1 ] -1.09 dBm 3.512000 ms 2Delta 2 [T1 ] -0.09 dB 136.000000 s 3Delta 3 [T1 ] 0.03 dB 272.000000 s 4Delta 4 [T1 ] -0.15 dB 544.000000 s TRG -12.5 dBmDate: 17.AUG.2018 20:34:13 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada Transmissions Burst Duration In 100 ms, 345MHz Pulse Number, 345MHz Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 28 of 46 Ref 30 dBmAtt 60 dB A 3DBRBW 3 MHzVBW 10 MHz TRGCenter 345.006 MHz10 ms/SWT 100 msVIEW*1 PK-70-60-50-40-30-20-1001020301Marker 1 [T1 ] -3.14 dBm 190.158897 zs 2Delta 2 [T1 ] 0.00 dB 17.000000 ms TRG -12.5 dBmDate: 17.AUG.2018 20:38:33Ref 30 dBmAtt 60 dB A RBW 3 MHzVBW 10 MHzTRGCenter 345.006 MHz2 ms/SWT 20 ms 3DB*1 PKVIEW-70-60-50-40-30-20-1001020301Marker 1 [T1 ] -3.41 dBm 190.158897 zs 2Delta 2 [T1 ] -0.03 dB 17.080000 ms TRG -12.5 dBmDate: 17.AUG.2018 20:40:18 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada Pulse Time, 345MHz Transmissions Burst Duration In 100 ms, 433.42MHz Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 29 of 46 Ref 30 dBmAtt 60 dB A RBW 3 MHzVBW 10 MHzCenter 345.006 MHz400 s/SWT 4 ms3DBTRG SGLVIEW*1 PK-70-60-50-40-30-20-1001020301Marker 1 [T1 ] -3.44 dBm 5.676000 ms 2Delta 2 [T1 ] 0.34 dB 128.000000 s 3Delta 3 [T1 ] 0.27 dB 280.000000 s 4Delta 4 [T1 ] 0.21 dB 536.000000 s TRG -12.5 dBmDate: 17.AUG.2018 20:42:45Ref 30 dBmAtt 60 dB A 3DBRBW 3 MHzVBW 10 MHz Center 433.429 MHz10 ms/SWT 100 msTRGVIEW*1 PK-70-60-50-40-30-20-1001020301Marker 1 [T1 ] 1.23 dBm -520.501746 zs 2Delta 2 [T1 ] -0.15 dB 15.800000 ms TRG -12.5 dBmDate: 17.AUG.2018 21:54:26 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada Pulse Number, 433.42MHz Pulse Time, 433.42MHz Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 30 of 46 Ref 30 dBmAtt 60 dB A RBW 3 MHzVBW 10 MHz Center 433.429 MHz2 ms/SWT 20 ms3DBTRG*1 PKVIEW-70-60-50-40-30-20-1001020301Marker 1 [T1 ] 1.32 dBm -520.501746 zs 2Delta 2 [T1 ] -0.40 dB 15.960000 ms TRG -12.5 dBmDate: 17.AUG.2018 21:55:56Ref 30 dBmAtt 60 dB A RBW 3 MHzVBW 10 MHz3DB Center 433.429 MHz400 s/SWT 4 msTRGVIEW*1 PK-70-60-50-40-30-20-1001020301Marker 1 [T1 ] 1.50 dBm 5.000000 ms 2Delta 2 [T1 ] -0.52 dB 200.000000 s 3Delta 3 [T1 ] -0.12 dB 304.000000 s 4Delta 4 [T1 ] -0.64 dB 400.000000 s TRG -12.5 dBmDate: 17.AUG.2018 22:00:11 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada Transmissions Burst Duration In 100 ms, 433.92MHz Pulse Number, 433.92MHz Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 31 of 46 Ref 30 dBmAtt 60 dB A 3DBRBW 3 MHzVBW 10 MHz TRGCenter 433.93 MHz10 ms/SWT 100 msVIEW*1 PK-70-60-50-40-30-20-1001020301Marker 1 [T1 ] 1.14 dBm 200.000000 s 2Delta 2 [T1 ] 0.00 dB 25.200000 ms TRG -12.5 dBmDate: 17.AUG.2018 21:41:18Ref 30 dBmAtt 60 dB A RBW 3 MHzVBW 10 MHz Center 433.93 MHz3 ms/SWT 30 ms3DBTRGVIEW*1 PK-70-60-50-40-30-20-1001020301Marker 1 [T1 ] 1.29 dBm -40.000000 s 2Delta 2 [T1 ] -0.24 dB 26.540000 ms TRG -12.5 dBmDate: 17.AUG.2018 21:42:57 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada Pulse Time, 433.92MHz Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 32 of 46 Ref 30 dBmAtt 60 dB A RBW 3 MHzVBW 10 MHz3DBCenter 433.93 MHz400 s/SWT 4 msTRG SGLVIEW*1 PK-70-60-50-40-30-20-1001020301Marker 1 [T1 ] -2.34 dBm -6.736559 zs 2Delta 2 [T1 ] 3.02 dB 2.512000 ms 3Delta 3 [T1 ] 3.02 dB 2.776000 ms 4Delta 4 [T1 ] 3.20 dB 3.016000 ms TRG -12.5 dBmDate: 17.AUG.2018 21:47:54 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada 4.6 20 dB Occupied Bandwidth Date Performed:
August 20, 2018 Test Standard:
Title 47 CFR Part 15: Subpart C, 15.231 (c) o Test Method:
o ANSI C63.10-2013 Required Limit(s):
o The bandwidth of the emission shall be no wider than 0.25% of the center frequency for devices operating above 70 MHz and below 900 MHz. For devices operating above 900 MHz, the emission shall be no wider than 0.5% of the center frequency. Bandwidth is determined at the points 20 dB down from the modulated carrier. Method of Measurement:
o As called in the ANSI C63.10-2013 standard. Result:
The EUT complies with the applicable standard. Data & Plot:
Data, 20 dB OBW Center frequency 0.5% of center frequency 20 dB Bandwidth Result MHz 319.5 344.92 345 433.42 433.92 kHz 798.75 862.3 862.5 1083.55 1084.8 kHz 61.6 52 56 67.6 48.4 Pass Pass Pass Pass Pass Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 33 of 46 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada 20 dB Occupied Bandwidth, 319.5 MHz 20 dB Occupied Bandwidth, 344.92 MHz Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 34 of 46 A Att 20 dBRef 90 dBV 1 PKMAXHCenter319.5056 MHzSpan200 kHz20 kHz/3DBRBW 10 kHzVBW 30 kHzSWT 2.5 ms-1001020304050607080901Marker 1 [T1 ] 71.70 dBV 319.506000000 MHz2Delta 2 [T1 ] -20.31 dB -26.400000000 kHz3Delta 3 [T1 ] -20.64 dB 35.200000000 kHzDate: 20.AUG.2018 21:29:35 A Att 20 dBRef 90 dBVCenter344.9472 MHzSpan200 kHz20 kHz/3DBRBW 10 kHzVBW 30 kHzSWT 2.5 ms 1 PKMAXH-1001020304050607080901Marker 1 [T1 ] 69.70 dBV 344.947200000 MHz2Delta 2 [T1 ] -20.00 dB -26.800000000 kHz3Delta 3 [T1 ] -20.51 dB 25.200000000 kHzDate: 20.AUG.2018 21:52:19 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada 20 dB Occupied Bandwidth, 345 MHz 20 dB Occupied Bandwidth, 433.92 MHz Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 35 of 46 A Att 20 dBRef 90 dBV Center345.0056 MHzSpan200 kHz20 kHz/3DBRBW 10 kHzVBW 30 kHzSWT 2.5 ms1 PKVIEW-1001020304050607080901Marker 1 [T1 ] 69.63 dBV 345.005600000 MHz2Delta 2 [T1 ] -19.79 dB -26.800000000 kHz3Delta 3 [T1 ] -19.83 dB 29.200000000 kHzDate: 20.AUG.2018 21:32:34 A Att 20 dBRef 90 dBVCenter433.9296 MHzSpan200 kHz20 kHz/3DBRBW 10 kHzVBW 30 kHzSWT 2.5 ms 1 PKMAXH-1001020304050607080901Marker 1 [T1 ] 70.04 dBV 433.929600000 MHz2Delta 2 [T1 ] -19.98 dB -25.600000000 kHz3Delta 3 [T1 ] -19.99 dB 22.800000000 kHzDate: 20.AUG.2018 21:40:26 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada 20 dB Occupied Bandwidth, 433.42 MHz Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 36 of 46 A Att 20 dBRef 90 dBVCenter433.4288 MHzSpan200 kHz20 kHz/3DBRBW 10 kHzVBW 30 kHzSWT 2.5 ms 1 PKMAXH-1001020304050607080901Marker 1 [T1 ] 69.77 dBV 433.428800000 MHz2Delta 2 [T1 ] -19.93 dB -31.200000000 kHz3Delta 3 [T1 ] -20.02 dB 36.400000000 kHzDate: 20.AUG.2018 21:45:41 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada 99% Occupied Bandwidth Date Performed:
August 20, 2018 Test Standard:
Title 47 CFR Part 15: Subpart C, 15.231 (c) o o RSS-210 Issue 9, A.1.3 o RSS-Gen Issue 4, 6.6 Test Method:
o ANSI C63.10-2013 Required Limit(s):
o The 99% bandwidth of momentarily operated devices shall be less or equal to 0.25% of the centre frequency for devices operating between 70 MHz and 900 MHz. For devices operating above 900 MHz, the 99% bandwidth shall be less or equal to 0.5% of the centre frequency. Method of Measurement:
o As called in the ANSI C63.10-2013 standard. Modifications:
No modification was required to comply for this test. Result:
The EUT complies with the applicable standard. Data & Plot:
Data, 99% OBW Center frequency 0.5% of center frequency 99% Bandwidth Result MHz 319.5 344.92 345 433.42 433.92 kHz 798.75 862.3 862.5 1083.55 1084.8 kHz 121.2 142.8 142.8 160 148.4 Pass Pass Pass Pass Pass 4.7 Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 37 of 46 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada 99% Occupied Bandwidth, 433.42 MHz 99% Occupied Bandwidth, 433.92 MHz Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 38 of 46 A Ref 90 dBVAtt 10 dB 1 PKMAXHCenter433.4288 MHzSpan200 kHz20 kHz/3DBRBW 10 kHzVBW 30 kHzSWT 2.5 ms-1001020304050607080901Marker 1 [T1 ] 71.69 dBV 433.428800000 MHzOBW160.000000000 kHzT1Temp 1 [T1 OBW] 45.15 dBV 433.348400000 MHzT2Temp 2 [T1 OBW] 47.03 dBV 433.508400000 MHzDate: 20.AUG.2018 21:59:51 A Ref 90 dBVAtt 10 dBCenter433.9296 MHzSpan200 kHz20 kHz/3DBRBW 10 kHzVBW 30 kHzSWT 2.5 ms 1 PKMAXH-1001020304050607080901Marker 1 [T1 ] 67.67 dBV 433.929600000 MHzOBW148.400000000 kHzT1Temp 1 [T1 OBW] 40.92 dBV 433.856800000 MHzT2Temp 2 [T1 OBW] 44.78 dBV 434.005200000 MHzDate: 20.AUG.2018 21:58:37 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada 99% Occupied Bandwidth, 319.5 MHz 99% Occupied Bandwidth, 345 MHz Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 39 of 46 A Ref 90 dBVAtt 10 dBCenter319.5072 MHzSpan200 kHz20 kHz/3DBRBW 10 kHzVBW 30 kHzSWT 2.5 ms 1 PKMAXH-1001020304050607080901Marker 1 [T1 ] 69.69 dBV 319.505600000 MHzOBW121.200000000 kHzT1Temp 1 [T1 OBW] 43.02 dBV 319.455600000 MHzT2Temp 2 [T1 OBW] 44.40 dBV 319.576800000 MHzDate: 20.AUG.2018 21:56:58 A Ref 90 dBV MAXH1 PKAtt 10 dBCenter345.0056 MHzSpan200 kHz20 kHz/3DBRBW 10 kHzVBW 30 kHzSWT 2.5 ms-1001020304050607080901Marker 1 [T1 ] 64.04 dBV 345.005600000 MHzOBW142.800000000 kHzT1Temp 1 [T1 OBW] 34.70 dBV 344.936000000 MHzT2Temp 2 [T1 OBW] 39.38 dBV 345.078800000 MHzDate: 20.AUG.2018 21:54:35 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada 99% Occupied Bandwidth, 344.92 MHz Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 40 of 46 A Ref 90 dBVCenter344.9472 MHzSpan200 kHz20 kHz/ MAXH1 PKAtt 10 dB3DBRBW 10 kHzVBW 30 kHzSWT 2.5 ms-1001020304050607080901Marker 1 [T1 ] 66.54 dBV 344.946800000 MHzOBW142.800000000 kHzT1Temp 1 [T1 OBW] 40.24 dBV 344.878000000 MHzT2Temp 2 [T1 OBW] 39.62 dBV 345.020800000 MHzDate: 20.AUG.2018 21:53:49 4.8 Receiver Radiated Emissions QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada Date Performed:
August 9, 2018 Test Standard:
o RSS-Gen Issue 4, 7.1 Test Method:
o ANSI C63.4-2014 Required Limit(s):
Spurious emissions from receivers shall not exceed the radiated limits shown below Frequency, f
(MHz) 30 88 88 216 216 960 above 960 Field strength
(dBV/m) 40.0 43.5 46.0 54.0 Note 1: The above field strength limits are specified at a distance of 3 meters. The tighter limits apply at the band edges. Method of Measurement:
The EUT was tested in our 3 m SAC and was positioned on the center of the turntable. The transmitter was set for continuous transmission. The device was measured for all radiated emissions from 30 MHz to 1 GHz. The EUT was pre-scanned in 3 different orthogonal orientations and was found to radiate highest when placed flat on the table top as indicated in the test photos. Modifications:
No modification was required to comply for this test. Result:
The EUT complies with the applicable standard. Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 41 of 46 Data/Plot:
QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada Radiated Emissions (below 1GHz) scanned at 3m SAC Remark: All radiated emissions were at least 20dB below the required limit line. Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 42 of 46 Level in dBV/m Appendix A: TEST SETUP PHOTOS QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada Radiated Emissions below 30 MHz at the 3m SAC Radiated Emissions 30M 1 GHz at the 3m SAC Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 43 of 46 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada Radiated Emissions Above 1 GHz at the 3m SAC Radiated Emissions Above 1 GHz at the 3m SAC, EUT setup Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 44 of 46 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada Appendix B: ABBREVIATIONS Abbreviation AC AM CE CISPR DC EFT EMC EMI ESD EUT FCC IC ICES IEC LISN OATS RF RMS SAC Definition Alternating Current Amplitude Modulation European Conformity Comit International Spcial des Perturbations Radiolectriques Direct Current Electrical Fast Transient ElectroMagnetic Compatibility ElectroMagnetic Interference ElectroStatic Discharge Equipment Under Test Federal Communications Commission Industry Canada Interference Causing Equipment Standard International Electrotechnical Commission Line Impedance Stabilizing Network Open Area Test Site Radio Frequency Root-Mean-Square Semi-Anechoic Chamber Client: Versa Wireless Inc Report Number: E10676-1804_ Versa-PIR-MultiP_Rev1.1 Page 45 of 46 QAI Laboratories 3980 North Fraser Way Burnaby, BC, V5J 5K5 Canada END OF REPORT
1 | Test Setup Photos | Test Setup Photos | 432.20 KiB | July 25 2019 |
19 - 2AD9X-MOTION-X: Test Setup Photos Equipment Under Test (EUT) - Photo 1 Emissions Setup - Photo 2 Radiated Emissions RELF 3m SAC Setup Photo 3 Radiated Spurious Emissions (Under 30MHz) 3m SAC Setup Photo 4 Radiated Spurious Emissions (above 1 GHz) SAC Test Setup Photo 5
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2019-07-25 | 433.92 ~ PowerOutput | DSC - Part 15 Security/Remote Control Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2019-07-25
|
||||
1 | Applicant's complete, legal business name |
Versa Wireless Inc.
|
||||
1 | FCC Registration Number (FRN) |
0024185001
|
||||
1 | Physical Address |
103 - 19292 60th Ave.
|
||||
1 |
Surrey BC, N/A V3S 3M2
|
|||||
1 |
Canada
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
t******@timcoengr.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2AD9X
|
||||
1 | Equipment Product Code |
MOTION-X
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
J******** C******
|
||||
1 | Title |
General Manager
|
||||
1 | Telephone Number |
604-4********
|
||||
1 | Fax Number |
604-4********
|
||||
1 |
j******@versawireless.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DSC - Part 15 Security/Remote Control Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Motion Detector - Versa Motion | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
QAI LABORATORIES LTD.
|
||||
1 | Name |
P****** S******
|
||||
1 | Telephone Number |
604-5********
|
||||
1 | Fax Number |
604-5********
|
||||
1 |
p******@qai.org
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15.231 | 319.5 | 319.5 | |||||||||||||||||||||||||||||||||||||
1 | 2 | 15.231 | 344.94 | 344.94 | |||||||||||||||||||||||||||||||||||||
1 | 3 | 15.231 | 345 | 345 | |||||||||||||||||||||||||||||||||||||
1 | 4 | 15.231 | 433.42 | 433.42 | |||||||||||||||||||||||||||||||||||||
1 | 5 | 15.231 | 433.92 | 433.92 |