EVX-531 Operating Manual prOgraMMable FunctiOns/Features IP57 Submersible (1 m/30 min.) 3 Programmable Function Keys 2-Tone Encode/Decode MDC-1200 Encode/Decode Scan Group Scan Dual Watch FM-Scan (Follow-Me Scan) TA Scan Privacy VOX Talk Around Emergency Lone Worker TX Save Disable ARTS (Auto Range Transpond System) ARTSII FCC ID: AXI11133020IC: 10239A-11133020 cOntents Advanced.Operation...............................................11 Programmable Key Functions ..........................11 Description of Operating Functions .................13 Lock..........................................................................19 ARTSTM.(Auto.Range.Transpond.System)...........19 ARTSIITM.(Auto.Range.Transpond.System)........19 Optional.Accessories...............................................20 Introduction...............................................................1 Warning!.FCC.RF.Exposure.Requirements...........2 Before.You.Begin.......................................................4 Battery Pack Installation and Removal ...............4 Battery Charging ..................................................4 Low Battery Indication ........................................5 Belt Clip Installation and Removal .....................6 Controls.&.Connectors.............................................7 Operation...................................................................8 Preliminary Steps .................................................8 Operation Quick Start ..........................................8 Automatic Time-Out Timer ...............................10 Congratulations!
You now have at your fingertips a valuable communications tool-a Vertex Standard two-way radio! Rugged, reliable and easy to use, your Vertex Standard radio will keep you in constant touch with your colleagues for years to come, with negligible maintenance down-time. Please take a few minutes to read this manual carefully. The information presented here will allow you to derive maximum performance from your radio, in case questions arise later on. Important.Note r There are no owner-serviceable parts inside the radio. All service jobs must be referred to an authorized Vertex Standard Service Representative. r In order to maintain the specified water integrity performance, periodic maintenance is recommended. r Should the radio sustain a severe shock (e.g. if it is dropped), the water integrity may be compromised, requiring service. Should this occur, contact your Authorized Vertex Standard Dealer. FCC ID: AXI11133020IC: 10239A-11133020 IntroductIon The EVX-531 is full-featured Hand-Held Digital/Analog Transceiver designed for business communications in the VHF/UHF Land Mobile bands. This transceiver is designed for reliable business communications in a wide variety of applications with a wide range of operating capability provided by their leading-edge design. The EVX-531 allows to 32-channel capacity and 2 groups. Important channel frequency data is stored in the flash memory on the CPU, and is easily programmable by Vertex Standard dealers using a personal computer and the Vertex Standard Programming Cable and CE142 Software. The pages which follow will detail the many advanced features provided in the EVX-531 transceiver. After reading this manual, you may wish to consult with your Network Administrator regarding precise details of the configura-
tion of this equipment for use in your application. Important Notice for North American Users Regarding 406 MHz Guard Band The U.S. Coast Guard and National Oceanographic and Atmospheric Administration have requested the cooperation of the U.S. Federal Communications Commission in preserving the integrity of the protected frequency range 406.0 to 406.1 MHz, which is reserved for use by distress beacons. Do not attempt to pro-
gram this apparatus, under any circumstances, for operation in the frequency range 406.0 - 406.1 MHz if the apparatus is to be used in or near North America. Warning - Frequency band 406 - 406.1 MHz is reserved for use ONLY as a distress beacon by the US Coast Guard and NOAA. Under no circumstance should this frequency band be part of the pre programmed oper-
ating frequencies of this radio. EVX-531 OpErating Manual 1 FCC ID: AXI11133020IC: 10239A-11133020 WarnIng! Fcc rF ExposurE rEquIrEmEnts This Radio has been tested and complies with the Federal Communications Commission (FCC) RF exposure limits for Occupational Use/Controlled exposure environment. In addition, it complies with the following Standards and Guidelines:
FCC 96-326, Guidelines for Evaluating the Environmental Effects of Radio-Frequency Radiation. FCC OET Bulletin 65 Edition 97-01 (2001) Supplement C, Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields. ANSI/IEEE C95.1-1992, IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequen-
cy Electromagnetic Fields, 3 kHz to 300 GHz. ANSI/IEEE C95.3-1992, IEEE Recommended Practice for the Measurement of Potentially Hazardous Electro-
magnetic Fields - RF and Microwave. WARNING:
This radio generates RF electromagnetic energy during transmit mode. This radio is designed for and clas-
sified as Occupational Use Only, meaning it must be used only during the course of employment by indi-
viduals aware of the hazards, and the ways to minimize such hazards. This radio is not intended for use by the General Population in an uncontrolled environment. CAUTION:
To ensure that your expose to RF electromagnetic energy is within the FCC allowable limits for occupa-
tional use, always adhere to the following guidelines:
This radio is NOT approved for use by the general population in an uncontrolled exposure environment. This radio is restricted to occupational use, work related operations only where the radio operator must have the knowledge to control his or her RF exposure conditions. 2 EVX-531 OpErating Manual FCC ID: AXI11133020IC: 10239A-11133020 WarnIng! Fcc rF ExposurE rEquIrEmEnts When transmitting, hold the radio in a vertical position with its microphone 2 inches (5 cm) away from your mouth and keep the antenna at least 2 inches (5 cm) away from your head and body. The radio must be used with a maximum operating duty cycle not exceeding 50%, in typical Push-to-
Talk configurations. DO NOT transmit for more than 50% of total radio use time (50% duty cycle). Transmitting more than 50% of the time can cause FCC RF exposure compliance requirements to be exceeded. To keep the Body Worn configuration with the Vertex Standard CLIP-20 belt-clip, reduce the maximum operating duty cycle still more. The radio is transmitting when the red LED on the top of the radio is illuminated. You can cause the ra-
dio to transmit by pressing the P-T-T button. SAR compliance for body-worn use was only demonstrated for the specific belt-clip (CLIP-20). Other body-worn accessories or configurations may NOT comply with the FCC RF exposure requirements and should be avoided. When operate the radio with the Vertex Standard CLIP-20 belt-clip, make the transmission time as short as possible, to keep the Body Worn configuration. Always use Vertex Standard authorized accessories. The information listed above provides the user with the information needed to make him or her aware of RF exposure, and what to do to assure that this radio operates with the FCC RF exposure limits of this radio. Electromagnetic Interference/Compatibility During transmissions, this radio generates RF energy that can possibly cause interference with other de-
vices or systems. To avoid such interference, turn off the radio in areas where signs are posted to do so. Do not operate the transmitter in areas that are sensitive to electromagnetic radiation such as hospitals, health care facilities, aircraft, and blasting sites. EVX-531 OpErating Manual 3 FCC ID: AXI11133020IC: 10239A-11133020 BEForE You BEgIn Battery Pack Installation and Removal To install the battery pack, align the battery pack to the radio with an offset about 1/2 inch (1.5 cm) from the top edge of battery compartment, then slide the battery pack upward until it locks in place with a Click. To remove the battery, turn the radio off and re-
move any protective cases. Slide the Battery Pack Latch on the bottom of the radio toward the front panel while sliding the battery down about 1/2 inch (1.5 cm). Then lift the battery out from the radio. Do not attempt to open any of the re-
chargeable Lithium-Ion packs, as they could explode if accidentally short-circuited. 4 Battery Charging Remove the Spacer Plate from the nest of the optional CD-58 Desktop Charger, if the Battery Spacer is installed. Insert the DC plug from the optional PA-55 AC Adapter into the DC jack on the rear panel of the optional CD-58 Desktop Charger, and then con-
nect the AC power cable between the AC jacks on the PA-55 AC Adapter and the AC line outlet. Insert the battery pack into the CD-58 Desktop Charger while aligning the slots of the battery pack with the guides in the nest of the CD-58;
refer to the following illustration for details on Spacer Plate PA-55 CD-58 EVX-531 OpErating Manual FCC ID: AXI11133020IC: 10239A-11133020 BEForE You BEgIn proper positioning of the battery pack. If charging with the transceiver attached, turn the transceiver off. The antenna jack should be at the left side when viewing the charger from the front. If the battery pack is inserted correctly, the LED indicator will glow red. A fully-discharged battery pack will charge completely in 1.5 - 3.0 hours
(depending on the battery pack being charged). When charging is completed, the LED indicator will change to green. Disconnect the battery pack from the CD-58 Desktop Charger and unplug the PA-55 AC Adapter from the AC line outlet. 1) Always use the Vertex Standard FNB-
V133LI or FNB-V134LI Lithium-Ion Bat-
tery Pack. 2) Use only the Vertex Standard CD-58 Desktop Charger and the Vertex Standard PA-55 AC Adapter. 3) To reduce the risk of explosion, recharge the bat-
teries outside of hazardous locations. 4) Perform the battery charging where the ambient temperature range +41 F to +104 F (+5 C to +40 C). Charge out of this range could cause damage to the battery pack. EVX-531 OpErating Manual 5) Battery Pack shall not be exposed to excessive heat such as sunshine, fire, or the like. 6) Risk of explosion if battery is replaced by an in-
correct type. Dispose of used batteries according to the instructions 7) For further details and cautions of the charging, refer to the Operating Manual of the CD-58 Desk-
top Charger. Low Battery Indication As the battery discharges during use, the voltage gradually becomes lower. When the battery voltage becomes to low, substitute a freshly charged battery and recharge the depleted pack. The LED indicator on the top of the radio will blink red when the battery voltage is low. CAUTION Danger of explosion if battery is replaced with an incorrect battery. Replace only with the same or equivalent type. 5 FCC ID: AXI11133020IC: 10239A-11133020 BEForE You BEgIn Belt Clip Installation and Removal To install the Belt Clip: align the Belt Clip to the groove of the Battery pack, then press the Belt Clip downward until it locks in place with a Click. To remove the Belt Clip: use a flat head screw driver to press the Belt Clip Tab away from the battery pack to unlock the Belt Clip, then slide the Belt Clip upward to remove it. Belt Clip Tab 6 EVX-531 OpErating Manual FCC ID: AXI11133020IC: 10239A-11133020 controls & connEctors VOL/PWR Knob CH (Channel) Selector Antenna Jack TOP SEL Key 3 LED Indicator (Programmable) Default settings are:
Steady Red:
Steady Blue:
Blinking Green:
Steady Green:
Transmitting in progress (Analog) Transmitting in progress (Digital) Busy Channel Tone Squelch in defeated condition PTT Switch SIDE-1 Button SIDE-2 Button MIC/SP Jack
(External MIC/SP) EVX-531 OpErating Manual 7 Speaker Battery Pack Latch Microphone FCC ID: AXI11133020IC: 10239A-11133020 Preliminary Steps Install a charged battery pack onto the transceiver, as described previously. Screw the supplied antenna onto the Antenna jack. Never attempt to operate this transceiver without an antenna connected. If you have a Speaker/Mi-
crophone, we recommend that it not be connected un-
til you are familiar with the basic operation of the EVX-531. IMPORTANT NOTE Water resistance of the transceiver (IP57: 1 meter / 30 minutes) is assured only when the following conditions:
Battery pack is attached to the transceiver;
Antenna is connected to the antenna jack;
and MIC/SP cap is installed in the MIC/
SP jack. opEratIon Operation Quick Start Turn the top panels VOL/PWR knob clock-
wise to turn the radio on. Turn the top panels CH Selector knob to choose the desired operating channel. The radio an-
nounces the channel number, if the Channel Announcement Feature is worked. If you want to select the operating channel from a different Channel Group, press the Program-
mable key (assigned to the group up function) to change the Channel Group you want before selecting the operating channel. 8 EVX-531 OpErating Manual FCC ID: AXI11133020IC: 10239A-11133020 opEratIon Rotate the VOL/PWR knob to set the volume level. If no signal is present on the analog channel, press and hold in the SIDE-1 button
(under the PTT switch) more than 2 seconds;
background noise will now be heard, and you may use this to set the VOL/PWR knob for the desired audio level. Press and hold the SIDE-1 button more than 2 seconds (or press the SIDE-1 button twice) to quiet the noise and resume nor-
mal (quiet) monitoring. To transmit, monitor the channel and make sure it is clear. Press and hold the PTT switch. Speak into the microphone area of the front panel grille in a normal voice level. To re-
turn to the Receive mode, release the PTT switch. Press the (Orange) TOP SEL key or SIDE-2 button to activate one of the pre programmed functions which may have been enabled at the time of programming by the dealer. See the next section for details regarding the available features. 3 EVX-531 OpErating Manual 9 FCC ID: AXI11133020IC: 10239A-11133020 opEratIon If a Speaker/Microphone is available, remove the plastic cap and its two mounting screws from the right side of the transceiver, then align the connector of the Speaker/Microphone on the radio; secure the connector pin using the screws supplied with the Speaker/Microphone. Hold the speaker grille up next to your ear while receiving. To transmit, press the PTT switch on the Speaker/Microphone, just as you would on the main transceivers body, and speak into the microphone on a normal voice level. VX-200 Note 1): Save the original plastic cap and its mounting screws. They should be reinstalled when not using the Speaker/Microphone. 2) When you press the PTT switch on the Speak-
er/Microphone, it disables the internal micro-
phone, and vice versa. 10 If the Busy Channel Lockout feature has been programmed on a channel, the radio will not transmit when a carrier is present. Instead, the ra-
dio will generate short beep three times. Release the PTT switch and wait for the channel to be clear of activity. If the BCLO (Busy Channel Lockout), CTCSS Lockout, or Digital Coded Squelch (DCS) Lock-
out has been programmed on a channel, the radio can transmit only when there is no carrier being received (BCLO) or when the carrier being re-
ceived includes the correct CTCSS tone or DCS code. Automatic Time-Out Timer If the selected channel has been programmed for au-
tomatic time-out, you must limit the length of each transmission. While transmitting, a beep will sound 10 seconds before time-out. Another beep will sound just before the deadline; the top panels red LED (TX indicator) will disappear and transmission will cease soon thereafter. To resume transmitting, you must re-
lease the PTT switch and wait for the penalty timer to expire. EVX-531 OpErating Manual FCC ID: AXI11133020IC: 10239A-11133020 advancEd opEratIon Programmable Key Functions The EVX-531 provides the programmable TOP SEL, SIDE-1, and SIDE-2 function keys. These Programmable Function keys can be custom-
ized, via programming by your Vertex Standard deal-
er, to meet your communications/network require-
ments. The possible Programmable key programming fea-
tures are illustrated on the next page, and their func-
tions are explained beginning after page 13. For fur-
ther details, contact your Vertex Standard dealer. In this chapter, the following icons are used to indi-
cate features supported in either the Analog mode or Digital mode:
: Indicates a Analog mode only feature.
: Indicates a Digital mode only feature. For features that are available in both Analog and Digital modes, no icon is shown. For future reference, check the box next to each func-
tion that has been assigned to the Programmable key on your particular radio, and keep it handy. EVX-531 OpErating Manual 11 FCC ID: AXI11133020IC: 10239A-11133020 advancEd opEratIon programmaBlE KEY
(prEss KEY / prEss and Hold KEY) SIDE-2 SIDE-1 TOP SEL programmaBlE KEY
(prEss KEY / prEss and Hold KEY) SIDE-2 SIDE-1 TOP SEL FunctIon None Monitor Monitor -Momentarily-
Low Power Privacy SQL OFF SQL OFF -Momentarily-
Beep Off Whisper VOX CH Announcement VOX Anti-Trip Emergency Lone Worker Group Change PRI-2 PRI-2 Set
FunctIon PRI-2 Disable Scan Group Scan Dual Watch FM Scan (Follow-Me Scan) TA Scan SCAN Set Talk Around (TA) RESET Call 1 Call 2 Call 3 Speed Dial Call Duty TX Save Disable Lock
12 EVX-531 OpErating Manual FCC ID: AXI11133020IC: 10239A-11133020 advancEd opEratIon Description of Operating Functions monItor Press (or press and hold) the assigned Programmable key to cancel any signaling features; the LED indica-
tor will glow green. monItor -momEntarIlY-
Cancel any signaling features while pressing the as-
signed programmable key. loW poWEr Press (or press and hold) the assigned Programmable key to set the radios transmitter to the Low Power mode, thus extending battery life. Press (or press and hold) the key again to return to Normal transmit power when in difficult terrain. prIvacY Press (or press and hold) the assigned Programmable key to toggle the Privacy feature On and Off. The privacy feature keep the secrecy of your commu-
nication contents. sql oFF Press (or press and hold) the assigned programmable key to open the SQL to hear background noise (unmute the audio). sql oFF -momEntarIlY-
Opens the SQL to hear background noise (unmute the audio) while pressing the assigned programmable key. BEEp oFF Press (or press and hold) the assigned Programmable key to disable the radio beeps temporarily. Again press (or press and hold) the assigned Programmable key to enable the radio beeps. WHIspEr Press (or press and hold) the assigned Programmable key to increase the microphone gain; thus you can speak in a low voice (whisper) temporarily. Again press (or press and hold) the assigned Programmable key to resume normal microphone gain. EVX-531 OpErating Manual 13 FCC ID: AXI11133020IC: 10239A-11133020 advancEd opEratIon vox Press (or press and hold) the assigned programmable key to turn the VOX function On or Off. You may disable the VOX function temporarily by press-
ing the PTT switch. vox antI-trIp Press (or press and hold) the assigned Programmable key to toggle the VOX Anti-Trip feature On and Off. When the VOX Anti-Trip feature is set to On, the transceiver does not activate the transmitter section from the receiver audio and own beep sound. EmErgEncY The EVX-531 include an Emergency feature which may be useful for alerting another party monitoring on the same frequency as your transceivers channel. Press the assigned Programmable key to initiate an emergency call on the pre-defined channel. For fur-
ther details contact your Vertex Standard dealer. lonE WorKEr Press (or press and hold) the assigned Programmable key to toggle the Lone Worker feature On and Off. The Lone Worker feature is designed to emit an alarm for 30 seconds when the Lone Worker Timer
(programmed by your Vertex Standard dealer) has ex-
pired. If the user does not reset the timer by pressing the PTT switch, the radio switches to the Emergency mode. group cHangE The EVX-531 has two Channel Groups. Press (or press and hold) the assigned Programmable key to change the Channel Group to the opposite Group. Once the desired Group is reached, rotate the CH Selector knob to select the desired channel within the selected Group. prI-2 Press (or press and hold) the assigned programmable key to recall the pre-programmed priority channel di-
rectly. This is pre-programmed by your Vertex Stan-
dard dealer. 14 EVX-531 OpErating Manual FCC ID: AXI11133020IC: 10239A-11133020 advancEd opEratIon prI-2 sEt Press (or press and hold) the assigned programmable key to toggle the current channel to the priority chan-
nel 2 enable and disable. prI-2 dIsaBlE Press (or press and hold) the assigned programmable key to disable the priority channel 2 of the group tem-
porarily. scan The Scanning feature is used to monitor multiple signals programmed into the transceiver. While scan-
ning, the transceiver will check each channel for the presence of a signal, and will stop on a channel if a signal is present. To activate scanning:
Press (or press and hold) the assigned Program-
mable key to activate scanning. The scanner will search the channels of each channel, looking for active ones; it will pause each time it finds a channel on which someone is speaking. Press (or press and hold) the assigned Program-
mable key again to disable scanning. Operation will revert to the programmed revert channel. Note: Your dealer may have programmed your radio to stay on one of the following channels if you press the PTT switch during scanning pause:
Scan Pause channel (Talk Back) Last Busy channel Priority-2 channel User Programmed channel (Select Channel) The channel which defined in the CH Selector knob. EVX-531 OpErating Manual 15 FCC ID: AXI11133020IC: 10239A-11133020 advancEd opEratIon group scan The Scanning feature is used to monitor multiple channels programmed into the transceiver. While scanning, the transceiver will check each channel of the programmed group for the presence of the signal, and will stop on a channel if a signal is present. Press (or press and hold) the assigned programmable key to activate the scanning on the selected groups. dual WatcH The Dual Watch feature is similar to the SCAN fea-
ture, except that only two channels are monitored:
The current operating channel; and The Priority-2 channel. To activate Dual Watch:
Press (or press and hold) the assigned Program-
mable key. The scanner will search the two channels; it will pause each time it finds a channel on which some-
one is speaking. To stop Dual Watch:
Press (or press and hold) the assigned Program-
Operation will revert to the Dual Watch Revert mable key. channel. Fm scan (FolloW-mE scan) The FM Scan feature checks a User-assigned Priority Channel regularly as you scan other channels. Thus, if only Channels 1, 3, and 5 (of the 8 available chan-
nels) are designated for Scanning, the user may nonetheless assign Channel 2 as the User-assigned Priority Channel via the FM Scan. To activate FM Scan, first select the channel you want to designate as the User-Assigned Priority Channel and press (or press and hold) the assigned program-
mable key. Then rotate the CH Selector knob to re-
call to the Scanning Start channel which has been programmed by your dealer to activate the scanner. When the scanner stops on an Active channel, the User-assigned Priority Channel will automatically be checked every few seconds; if activity is found on the User-assigned Priority Channel, the radio will switch between it and the Dealer-Assigned Priority Channel, if any. 16 EVX-531 OpErating Manual FCC ID: AXI11133020IC: 10239A-11133020 advancEd opEratIon ta scan Press (or press and hold) the assigned Programmable key to toggle the TA (Talk Around) scan feature On and Off. While TA scan is proceeding, the transceiver will search both the transmit and receive frequencies. When a signal is encountered on the receive frequen-
cy, the EVX-531 will pause until the signal disap-
pears. When a signal is encountered on the transmit frequency, the transceiver will check for activity on the receive frequency every few seconds (interval programmed by your Vertex Standard dealer). Note: The TA Scan feature does not activate on the Simplex Channel. scan sEt Press (or press and hold) the assigned Programmable key to add/delete the current channel to/from your scanning list. When the scanner is stopped, you may remove the channel from the scan list temporarily by pressing (or press and holding) this key. talK around (ta) Press (or press and hold) the assigned Programmable key to activate the Talk Around feature when you are operating on duplex channel systems (separate re-
ceive and transmit frequencies, utilizing a repeater station). The Talk Around feature allows you to by-
pass the repeater station and talk directly to a station that is nearby. This feature has no effect when you are operating on simplex channels, where the receive and transmit frequencies are already the same. Note that your dealer may have mode provision for Talk Around channels by programming repeater and Talk Around frequencies on two adjacent chan-
nels. If so, the key may be used for one of the other Pre-Programmed Functions. Note: The Talk Around feature does not activate on the Simplex Channel. rEsEt Press (or press and hold) the assigned programmable key to reset the RFC (Ready for Communication) condition. EVX-531 OpErating Manual 17 FCC ID: AXI11133020IC: 10239A-11133020 advancEd opEratIon call 1 to call 3 Press (or press and hold) the assigned Programmable key to send a 2-tone sequential tone group which is pre-defined. spEEd dIal Press (or press and hold) the assigned Programmable key to prepare the Speed Dial function. Press the PTT switch within 5 seconds of releasing the key to send a DTMF tone which is pre-defined. call Press (or press and hold) the assigned programmable key to send a 2-tone sequential tone. tx savE dIsaBlE Press (or press and hold) the assigned Programmable key to disable the Transmit Battery Saver, if you are operating in a location where high power is almost always needed. The Transmit Battery Saver helps extend battery life by reducing transmit power when a very strong signal from an apparently nearby station is being received. Under some circumstances, though, your hand-held radio may not be heard well at the other end of the communication path, and high power may be neces-
sary at all times. locK Press (or press and hold) the assigned Programmable key to lock the CH Selector knob, Programmable keys, and PTT switch. The precise lockout configura-
tion is programmed by your Vertex Standard Dealer. 18 EVX-531 OpErating Manual FCC ID: AXI11133020IC: 10239A-11133020 locK In order to prevent accidental channel change or inadvertent transmission, various aspects of the CH Selector knob, Programmable keys, and PTT switch may be locked. The precise lockout configuration is programmed by your Dealer. To locked out the key locking, turn the radio off. Now, press and hold the PTT and SIDE-2 key while turning the radio on again. To cancel locking, repeat this process. artstm (auto rangE transpond sYstEm) This system is designed to inform you when you and another ARTSTM-equipped station are within commu-
nication range. During ARTSTM operation, when the radio receives an incoming ARTSTM signal, a short beep will sound. If you move out of range for more than two minutes, your radio senses that no signal has been received;
a short triple-beep will sound. If you subsequently move back into communication range, as soon as the other station transmits, a short beep will sound again. artsIItm (auto rangE transpond sYstEm) The ARTSIITM system is enhanced feature of the ARTSTM which can be finding out the communication range of the radio individually by using the MDC-
1200 Encode/Decoder. EVX-531 OpErating Manual 19 FCC ID: AXI11133020IC: 10239A-11133020 optIonal accEssorIEs Availability of accessories may vary; some acces-
sories are supplied standard per local requirements, others may be unavailable in some regions. Check with your Vertex Standard Dealer for changes to this list. FNB-V133LI 7.4V, 1380 mAh Li-Ion Battery Pack FNB-V134LI 7.4V, 2300 mAh Li-Ion Battery Pack CD-58 PA-51 MH-66A4B MH-81A4B ATU-16B ATU-16C ATU-16D ATU-16F CSS450 CLIP-20 CE142 FIF-12 CT-106 CT-27 Desktop Charger AC Adapter Submersible Speaker Microphone Over-the-head VOX Compatible Headset UHF Antenna (400-420 MHz) UHF Antenna (420-450 MHz) UHF Antenna (450-470 MHz) UHF Antenna (470-520 MHz) Channel Selector Stopper Belt Clip PC Programming Software USB Programming Interface Connection Cable for FIF-12 Radio to Radio Cloning Cable 20 EVX-531 OpErating Manual FCC ID: AXI11133020IC: 10239A-11133020 The AMBE+2TM voice coding Technology embodied in this product is protected by intellectual property rights including patent rights, copyrights and trade secrets of Digital Voice Systems, Inc. This voice coding Technology is licensed solely for use within this Communications Equipment. The user of this Technology is explicitly prohibited from attempting to decompile, reverse engineer, or disassemble the Object Code, or in any other way convert the Object Code into a human-readable form. U.S. Pat. Nos. #5,870,405, #5,826,222, #5,754,974, #5,701,390, #5,715,365, #5,649,050, #5,630,011,
#5,581,656, #5,517,511, #5,491,772, #5,247,579, #5,226,084 and #5,195,166. Part 15.21: Changes or modifications to this device not expressly approved by Vertex Standard could void the users authorization to operate this device. FCC ID: AXI11133020IC: 10239A-11133020 Vertex Standard LMR, Inc. Copyright 2012 Vertex Standard LMR, Inc. All rights reserved. No portion of this manual may be reproduced without the permission of Vertex Standard LMR, Inc. FCC ID: AXI11133020IC: 10239A-11133020