all | frequencies |
|
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|---|
manuals | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 2 |
|
User Manual 1 | Users Manual | 3.57 MiB | April 30 2015 | |||
1 2 |
|
User Manual 2 | Users Manual | 3.81 MiB | April 30 2015 | |||
1 2 |
|
Internal Photos | Internal Photos | 1.51 MiB | April 30 2015 | |||
1 2 |
|
External Photos | External Photos | 74.98 KiB | April 30 2015 | |||
1 2 |
|
Label Info | ID Label/Location Info | 86.55 KiB | April 30 2015 | |||
1 2 |
|
Agent Authorization Letter | Cover Letter(s) | 25.21 KiB | April 30 2015 | |||
1 2 |
|
Antenna Specification | Operational Description | 1.00 MiB | April 30 2015 | |||
1 2 |
|
Attestation Letter | Attestation Statements | 30.80 KiB | April 30 2015 | |||
1 2 | Block Diagram | Block Diagram | April 30 2015 | confidential | ||||
1 2 | RF Exposure Info | April 30 2015 | ||||||
1 2 | RF Exposure Info | April 30 2015 | ||||||
1 2 |
|
Confidentiality Request | Cover Letter(s) | 14.59 KiB | April 30 2015 | |||
1 2 |
|
Cover Letter | Cover Letter(s) | 33.26 KiB | April 30 2015 | |||
1 2 |
|
KDB INQUIRY LETTER | Cover Letter(s) | 87.55 KiB | April 30 2015 | |||
1 2 | Operational Description | Operational Description | April 30 2015 | confidential | ||||
1 2 |
|
PCB LAYOUT | Schematics | 1.00 MiB | April 30 2015 | |||
1 2 | Parts List | Parts List/Tune Up Info | April 30 2015 | confidential | ||||
1 2 | RF Exposure Info | April 30 2015 | ||||||
1 2 | Schematics | Schematics | April 30 2015 | confidential | ||||
1 2 | Test Report | April 30 2015 | ||||||
1 2 | Test Report | April 30 2015 | ||||||
1 2 | Test Report | April 30 2015 | ||||||
1 2 | Test Report | April 30 2015 | ||||||
1 2 | Test Setup Photos | April 30 2015 | ||||||
1 2 | Test Setup Photos | April 30 2015 | ||||||
1 2 | Circuit Diagram | Schematics | April 30 2015 | confidential | ||||
1 2 | RF Exposure Info | April 30 2015 | ||||||
1 2 | Test Setup Photos | April 30 2015 |
1 2 | User Manual 1 | Users Manual | 3.57 MiB | April 30 2015 |
VIVIX-S 1717N User Manual Vieworks. 2015 All rights reserved. Under copyright laws, this manual should not be reproduced, in whole or in part, without the written permission of Vieworks. VIVIX-S 1717N User Manual Contents 1. Instruction ......................................................................................................................................... 8 1.1 Document Guide ..................................................................................................................................... 9 1.1.1 Caution Information ..................................................................................................................................................... 9 1.1.2 Target ................................................................................................................................................................................... 9 1.1.3 Symbols .............................................................................................................................................................................. 9 1.1.4 Notations .........................................................................................................................................................................10 1.1.5 Contact Department ...................................................................................................................................................10 1.2 Product Use Guide ................................................................................................................................ 11 1.2.1 Product Usage ...............................................................................................................................................................11 1.2.2 Disclaimer ........................................................................................................................................................................11 1.2.3 Product Disposal ..........................................................................................................................................................12 1.2.4 Trademarks ......................................................................................................................................................................12 1.3 Safety Instruction .................................................................................................................................. 13 1.3.1 Management and Authority ...................................................................................................................................13 1.3.2 Power Supply .................................................................................................................................................................13 1.3.3 Handling ...........................................................................................................................................................................14 1.3.4 Battery Pack and Charger ........................................................................................................................................15 1.3.5 Environment of Use ....................................................................................................................................................16 1.3.6 Problem Management ...............................................................................................................................................17 1.3.7 Maintenance and Inspection ..................................................................................................................................17 1.4 Product Usage Guide ............................................................................................................................ 18 1.4.1 Calibration .......................................................................................................................................................................18 1.4.2 Length Measurement .................................................................................................................................................18 1.4.3 Left/Right Marker.........................................................................................................................................................18 1.4.4 Image Backup ................................................................................................................................................................18 1.4.5 Use Limitations .............................................................................................................................................................19 1.4.6 Disposal ............................................................................................................................................................................19 1.4.7 Pediatric Application ..................................................................................................................................................19 1.4.8 Before Exposure ............................................................................................................................................................19 1.4.9 During Exposure ...........................................................................................................................................................20 1.4.10 Operating and Storage Environment .................................................................................................................20 1.4.11 Others................................................................................................................................................................................20 2. Product ............................................................................................................................................. 21 2.1 Overview ................................................................................................................................................. 22 2.1.1 Features ............................................................................................................................................................................22 2.2 Product Components ............................................................................................................................ 23 Rev.1.0 Page 2 of 151 VW40-153-006 VIVIX-S 1717N User Manual 2.2.1 Detector............................................................................................................................................................................23 2.2.2 SCU (System Control Unit) ......................................................................................................................................23 2.2.3 Battery & Charger .......................................................................................................................................................24 2.2.4 Accessories ......................................................................................................................................................................25 2.3 VIVIX-S 1717N Detector ...................................................................................................................... 26 2.3.1 Specifications .................................................................................................................................................................26 2.3.2 Drawing Sheet ...............................................................................................................................................................27 2.3.3 Functions .........................................................................................................................................................................29 2.3.4 Deco Sheet .....................................................................................................................................................................31 2.3.5 Wireless Communication..........................................................................................................................................33 2.3.6 Use Environment ..........................................................................................................................................................33 2.4 SCU Basic (FXRS-02A) .......................................................................................................................... 34 2.4.1 Specifications .................................................................................................................................................................34 2.4.2 Drawing Sheet ...............................................................................................................................................................34 2.4.3 Functions .........................................................................................................................................................................35 2.5 SCU Basic (FXRS-03A) .......................................................................................................................... 37 2.5.1 Specifications .................................................................................................................................................................37 2.5.2 Drawing Sheet ...............................................................................................................................................................37 2.5.3 Functions .........................................................................................................................................................................38 2.6 SCU mini (FXRS-04A) ............................................................................................................................ 40 2.6.1 Specifications .................................................................................................................................................................40 2.6.2 Drawing Sheet ...............................................................................................................................................................40 2.6.3 Functions .........................................................................................................................................................................41 2.7 Battery Pack [TBD] ................................................................................................................................ 43 2.7.1 Specifications .................................................................................................................................................................43 2.7.2 Drawing Sheet ...............................................................................................................................................................43 2.8 Battery Charger ..................................................................................................................................... 44 2.8.1 Specifications .................................................................................................................................................................44 2.8.2 Drawing Sheet ...............................................................................................................................................................44 2.9 Others ...................................................................................................................................................... 45 2.9.1 X-ray Generator (Recommended Exposure Condition)..............................................................................45 2.9.2 Recommended Specifications of Workstation (PC) .....................................................................................45 2.9.3 Recommended Specifications of Grid ................................................................................................................45 3. System Configuration ................................................................................................................... 46 3.1 Detector Connection Methods ........................................................................................................... 47 3.1.1 Wireless Connection ...................................................................................................................................................47 3.1.2 Wired Connection ........................................................................................................................................................48 Rev.1.0 Page 3 of 151 VW40-153-006 VIVIX-S 1717N User Manual 3.2 Diagram ................................................................................................................................................... 49 3.2.1 Block Diagram ...............................................................................................................................................................49 3.2.2 Wiring Diagram ............................................................................................................................................................49 3.3 System Configuration ........................................................................................................................... 50 3.3.1 AP Mode (SCU AP Mode)........................................................................................................................................50 3.3.2 Tether Interface Mode ...............................................................................................................................................51 3.3.3 External AP Mode ........................................................................................................................................................52 3.3.4 Detector AP Mode ......................................................................................................................................................53 3.3.5 Detector Stand-Alone Mode ..................................................................................................................................54 3.4 Generator Interface ............................................................................................................................... 55 3.4.1 AED (Auto Exposure Detection) Interface ........................................................................................................55 3.4.2 DR Trigger Interface ...................................................................................................................................................56 3.5 Configuring DR Trigger Interface ...................................................................................................... 57 3.5.1 Trigger Interface Way .................................................................................................................................................57 3.5.2 Packet Trigger ................................................................................................................................................................57 3.5.3 Line Trigger .....................................................................................................................................................................58 3.5.4 EXT_INF Port Pin Map ...............................................................................................................................................59 3.5.5 Input / Output Circuit ................................................................................................................................................61 4. Installation ....................................................................................................................................... 62 4.1 Battery Pack ........................................................................................................................................... 63 4.1.1 How to insert a battery pack .................................................................................................................................63 4.1.2 How to take out a battery pack ...........................................................................................................................64 4.1.3 How to charge a battery pack ..............................................................................................................................65 4.2 Product Installation .............................................................................................................................. 67 4.2.1 Connecting Devices ....................................................................................................................................................67 4.2.2 Booting up SCU ............................................................................................................................................................70 4.2.3 Booting up the Detector ..........................................................................................................................................70 4.2.4 Checking Status LED of Detector .........................................................................................................................71 4.3 Software Installation ............................................................................................................................. 73 4.3.1 Software Classification...............................................................................................................................................73 4.3.2 Software Installation ...................................................................................................................................................73 4.4 Windows Environment Setting ........................................................................................................... 74 4.4.1 Network Configuration .............................................................................................................................................74 4.4.2 Disabling Sleep Mode of Monitor .......................................................................................................................78 5. Setting .............................................................................................................................................. 79 5.1 Start Setting ........................................................................................................................................... 80 5.1.1 Setup Program ..............................................................................................................................................................80 Rev.1.0 Page 4 of 151 VW40-153-006 VIVIX-S 1717N User Manual 5.1.2 Checking Devices .........................................................................................................................................................80 5.1.3 Getting into the Devices ..........................................................................................................................................82 5.2 SCU Setting ............................................................................................................................................ 83 5.2.1 SCU Configuration ......................................................................................................................................................83 5.2.2 SCU Diagnosis ...............................................................................................................................................................86 5.3 Detector Setting .................................................................................................................................... 87 5.3.1 Detector Configuration .............................................................................................................................................87 5.3.2 Detector Power Save Function ..............................................................................................................................90 5.4 Changing the Wireless Setting ........................................................................................................... 92 5.4.1 Switching to the Detector AP Mode ..................................................................................................................92 5.4.2 Synchronizing the Wireless Setting .....................................................................................................................92 6. Calibration ....................................................................................................................................... 93 6.1 Calibration Dialogue ............................................................................................................................. 94 6.1.1 System Configuration Dialogue ............................................................................................................................94 6.1.2 Offset Calibration Dialogue ....................................................................................................................................97 6.1.3 Defect Calibration Dialogue ...................................................................................................................................98 6.1.4 Gain Calibration Dialogue .......................................................................................................................................99 6.2 Detector Configuration ...................................................................................................................... 100 6.3 Calibration Guide ................................................................................................................................ 102 6.4 Calibrating by Loading the Calibration Data ................................................................................. 103 6.4.1 Preparing Calibration Data ................................................................................................................................... 103 6.4.2 Loading Defect Calibration Data ....................................................................................................................... 103 6.4.3 Loading Gain Calibration Data ........................................................................................................................... 104 6.5 Direct Calibration ................................................................................................................................ 105 6.5.1 Prepration ..................................................................................................................................................................... 105 6.5.2 Offset Calibration ...................................................................................................................................................... 105 6.5.3 Gain Calibration ......................................................................................................................................................... 106 6.5.4 Auto Defect Correction .......................................................................................................................................... 107 6.5.5 Manual Defect Correction .................................................................................................................................... 110 7. Diagnosis, Inspection and Maintenance ................................................................................. 113 7.1 Diagnosis .............................................................................................................................................. 114 7.1.1 Image Diagnosis ........................................................................................................................................................ 114 7.1.2 Battery Pack Diagnosis ........................................................................................................................................... 116 7.1.3 Wireless Communication Diagnosis ................................................................................................................. 117 7.1.4 Communication Speed Diagnosis ..................................................................................................................... 118 7.2 Product Inspection .............................................................................................................................. 119 Rev.1.0 Page 5 of 151 VW40-153-006 VIVIX-S 1717N User Manual 7.2.1 Daily Inspection ......................................................................................................................................................... 119 7.2.2 Performance Inspection ......................................................................................................................................... 119 7.3 Self Diagnosis ...................................................................................................................................... 120 7.3.2 Self-Diagnosis Items of Detector and Measures ........................................................................................ 120 7.3.3 Self-Diagnosis Items of SCU and Measures ................................................................................................. 122 7.4 Cleaning and Disinfection ................................................................................................................. 123 7.5 Product Initialization .......................................................................................................................... 124 7.5.1 SCU Initialization ....................................................................................................................................................... 124 7.5.2 Detector Initialization .............................................................................................................................................. 125 7.5.3 Wireless Initialization of Detector ..................................................................................................................... 126 7.6 Replacing the Fuse of SCU (SCU Basic only) ................................................................................. 127 8. Troubleshooting ........................................................................................................................... 128 8.1 Trobleshooting ..................................................................................................................................... 129 8.1.1 Troubleshooting Guide ........................................................................................................................................... 129 8.1.2 Failed to Turn the Detector On .......................................................................................................................... 129 8.1.3 The Power Switch of SCU or Status LED is not worked ......................................................................... 129 8.1.4 Communication Test is failed .............................................................................................................................. 130 8.1.5 The Active LED and Data LED of the Detector are blinking ................................................................ 130 8.1.6 Errors in Detector LED ............................................................................................................................................ 131 8.1.7 Rapid Consumption of Battery ........................................................................................................................... 131 8.1.8 Battery Pack or Installation Part of Battery is Getting Hot ................................................................... 131 9. Regulatory Information .............................................................................................................. 132 9.1 Medical Equipment Safety Standards ............................................................................................. 133 9.1.1 Medical Equipment Classification ..................................................................................................................... 133 9.1.2 Product Safety Standard ........................................................................................................................................ 133 9.2 Radio Frequency Compliance Information ..................................................................................... 135 9.2.1 FCC Compliance ........................................................................................................................................................ 135 9.2.2 FCC SAR ........................................................................................................................................................................ 136 9.2.3 CE R&TTE SAR............................................................................................................................................................ 136 9.3 Labels and Symbols ............................................................................................................................ 137 9.3.1 Label ............................................................................................................................................................................... 137 9.3.2 Product Serial Number........................................................................................................................................... 143 9.3.3 Product Symbols ....................................................................................................................................................... 144 9.4 Guidance and Manufacturers Declaration for EMC ..................................................................... 145 9.4.1 Electromagnetic Emissions ................................................................................................................................... 145 9.4.2 Electromagnetic Immunity .................................................................................................................................... 145 Rev.1.0 Page 6 of 151 VW40-153-006 VIVIX-S 1717N User Manual 10. Information ................................................................................................................................ 148 10.1 Service Information ........................................................................................................................ 149 10.1.1 Product Lifetime ........................................................................................................................................................ 149 10.1.2 Regular Inspection and Maintenance ............................................................................................................. 149 10.1.3 Repair ............................................................................................................................................................................. 149 10.1.4 Replacement Parts Support ................................................................................................................................. 149 10.1.5 Consumables ............................................................................................................................................................... 149 10.2 Warranty ............................................................................................................................................ 150 10.3 Revision History ............................................................................................................................... 151 Rev.1.0 Page 7 of 151 VW40-153-006 This dev conditio any inte Changes void the operated 5150~52 FCC ID:
FCC ID:
WPEA-1 Host de Contains vice complie ons: (1) This erference rec es with part device may ceived, includ t 15 of the y not cause ding interfer FCC Rules. harmful int rence that m Operation terference, a may cause un is subject to and (2) this ndesired ope eration. o the follow device mus wing two st accept s or modific e users aut d in conjunc cations not e hority to op ction with an expressly ap perate the e ny other ant pproved by equipment. T enna or tran the party re This transmi nsmitter. esponsible fo tter must n or complian not be co-lo ce could ocated or 250 MHz ba and is restric ted to indoo or operation ns only. (for F FCC and CE)
) PFRFXRD-17 717NAW PFRFXRD-1 1717NAW in the RF mo odule do no ot use DFS b band. *RF modue FCC C ID:RYK-
121N. evice of the a s Transmitte approved m r Module FC odule shall b CC ID:RYK-W WPEA-121N be marked w with the follo owing item:
VIVIX-S 1717N User Manual 1. Instruction This section gives basic information of this manual and products with the safety guide. Document Guide Product Use Guide Safety Instruction Product Operation Guide Rev.1.0 Page 8 of 151 VW40-153-006 1.1 Document Guide VIVIX-S 1717N User Manual This User Manual explains how to use the VIVIX-S 1717N detector made by Vieworks, X-ray interface unit, and other peripheral equipment. With this user manual, you can install, set and manage the VIVIX-S 1717N detector as well as use its various functions. 1.1.1 Caution Information If the user is not fully aquainted with this manual, the product can be malfunctioned or unsuspected problem can be happened due to carelessness. To prevent any medical accidents, the user should fully understand the instructions of this manual before operating this product. 1.1.2 Target This manual is intended for service enginneers who install and set the VIVIX-S 1717N detector. 1.1.3 Symbols This product should be operated under the safety instructions with the warning or caution symbol in this manual. It is important for you to read and understand the contents with the following symbol for operating the products safely. Caution and Warning Symbol This symbol is used to indicate a potentially hazardous situation which may cause death, personal injury or substantial property damage if the instructions are ignored. Be sure to understand the instructions of this symbol for the safe operation. Information Symbol This symbol is used to indicate reference and complementary information related to the product. Users should read the instructions of this symbol carefully. Symbol for Change This symbol is indicated in the cases below. Items under consideration for adding, deleting or revising contents. Items ready to review for the expected product change. Items need a final review and approval. Items which need to improve sentences or images. Rev.1.0 Page 9 of 151 VW40-153-006 1.1.4 Notations Bold Types VIVIX-S 1717N User Manual We applied bold font style to the words which mean the products terms, or the words and sentences that are needed to transmit clear meaning to the customers. This helps you to easily distinguish the words from other technical ones for explaining functions. 1.1.5 Contact Department For any comments or inquiries regarding this document, contact via email below. Item Contents Department Customer Support Division in Vieworks E-mail CustomerSupport@vieworks.com Rev.1.0 Page 10 of 151 VW40-153-006 1.2 Product Use Guide VIVIX-S 1717N User Manual This chapter provides instructions about the use of product and disposal as well as the liability limit of Vieworks. 1.2.1 Product Usage 1 Only a physician or a legally certified operator should use this product. 2 The equipment should be kept in a safe and operable condition by maintenance personnel. 3 Observe the contents written in this user manual when installing and using this product. 4 Use only specifications of computers and image display monitors recommended by this user manual. 5 Use only the dedicated cables provided with this product. 6 For details about installing and using this product, consult your sales representative or a distributor. 1.2.2 Disclaimer 1 In no event shall Vieworks be liable for damage or loss arising from a fire, earthquake, any intentional or negligent action by users. 2 In no event shall Vieworks be liable for damage or loss arising from any trial usage, or other usage under abnormal conditions. 3 In no event shall Vieworks be liable for personal physical harm or property damage that is sustained when the instructions of this manual are not followed. 4 In no event shall Vieworks be liable for direct or indirect consequential damages arising from the use of this product. 5 In no event shall Vieworks be liable for any damage arising from moving, alteration, inspection or repair by a person other than authorized service engineers. 6 In no event shall Vieworks be liable for loss of image data for any reason. 7 Roentgenography, image processing, image reading, and image data storage must be performed in accordance with the laws of the country or region in which the product is being used. The user is responsible for maintaining the privacy of image data acquired from this product. It is the responsibility of the attending physicians to provide medical care services. Vieworks will not be 8 9 liable for faulty diagnoses. 10 Specifications, composition, and appearance of this product may change without prior notice. Rev.1.0 Page 11 of 151 VW40-153-006 1.2.3 Product Disposal VIVIX-S 1717N User Manual Disposal of this product in an unlawful manner may have a negative impact on human health and the environment. When disposing this product, therefore, be absolutely sure to follow the procedure which is in conformity with the laws and regulations applicable in your area. European Union (and EEA*) only This symbol indicates that this product is not to be disposed with your household waste, according to the WEEE Directive (2002/96/EC) and your national law. This product should be handed over to a designated collection point, e.g., on an authorized one-for-one basis when you buy a new similar product or to an authorized collection site for recycling electrical and electronic equipment (EEE). Improper handling of this type of waste could have a negative impact on the environment and human health due to potentially hazardous substances that are generally associated with EEE. At the same time, your cooperation in the correct disposal of this product will contribute to the effective usage of natural resources. For more information on where you can drop off your waste equipment for recycling, please contact your local city office, waste authority, approved WEEE scheme, or your household waste disposal service.
*EEA: Norway, Iceland, and Liechtenstein 1.2.4 Trademarks The name Vieworks and Vieworks logo are registered trademarks of Vieworks. Vieworks. 2015 All rights reserved. The copyright of this document is owned by Vieworks. Under copyright laws, this document cannot be reproduced, in whole or in part, without the written permission of Vieworks. Rev.1.0 Page 12 of 151 VW40-153-006 1.3 Safety Instruction VIVIX-S 1717N User Manual This product is designed and manufactured to ensure maximum safety of operation and to meet all the safety requirements applicable to electronic medical equipment. Follow these safeguards while using the products. If not, severe personal injury or substantial property damage can be happened. It is important for you to read and understand the contents of this manual before attempting to use the product. 1.3.1 Management and Authority The product should be installed, operated, and serviced according to Vieworks maintenance procedures and by personnel from Vieworks or distributor who providing purchase of the Vieworks product. Operation and maintenance should be done in strict compliance with the operation instructions contained in the manual. The system, in whole or in part, cannot be modified in any way without prior approval from Vieworks. Before authorizing any person to operate the system, verify that the person has read and fully understood the User Manual. The owner should make certain that only properly trained and fully qualified personnel are authorized to operate the equipment. An authorized operators list should be made and maintained. It is important that this User Manual be kept at hand, studied carefully, and reviewed periodically by the authorized operators. If a malfunction occurs, do not use this device until qualified personnel correct the problem. 1.3.2 Power Supply Do not operate the equipment using any type of power supply other than the one indicated on the rating label. Otherwise, it may result in a fire or electric shock. Do not supply power to more than one piece of equipment using the same AC outlet for this product. Doing so may result in a fire or electric shock. Do not connect a multiple portable socket-outlet or extension cord to the system. Doing so may result in a fire or electric shock. Always connect the three-core power cord plug to a grounded AC power outlet. Be sure to ground the equipment to an indoor grounded connector. Also, be sure to connect all the grounds for the system to a common ground. Do not use any power source other than the one provided with this product. Otherwise, a fire or electric shock may be caused due to a leakage. The owner should ensure continuous power supply to the system with voltage and current according to the product specifications. If the system is powered unstably during its operation, we recommend you to install UPS (Uninterrupted Power Supply) to avoid loss of data. Rev.1.0 Page 13 of 151 VW40-153-006 1.3.3 Handling VIVIX-S 1717N User Manual To make it easy to disconnect the plug at any time, avoid putting any obstacles near the outlet. Otherwise, it may not be possible to disconnect the plug in an emergency. Do not place a heavy object such as medical equipment on cables and cords, and do not pull, bend, bundle, or step on them. Doing so may damage their sheath. If you alter them, it may damage the cords which could result in a fire or electric shock. Securely plug the power cord into the AC outlet. If contact failure occurs, or if dust/metal objects come into contact with the exposed metal prongs of the plug, fire or electric shock may result. Be sure to turn OFF the power to each piece of equipment before connecting or disconnecting the cords. Otherwise, you may get an electric shock that could result in death or serious injury. Be sure to hold the plug or connector to disconnect the cord. If you pull the cord, the core wire may be damaged, resulting in a fire or electric shock. Do not handle the product with wet hands. You may experience an electric shock that could result in death or serious injury. Never disassemble or modify the equipment. Doing so may result in a fire or electric shock. Also, since the equipment incorporates parts that may cause an electric shock as well as other hazardous parts, touching them may cause death or serious injury. Do not connect any equipment which is not specified in this User Manual. Do not place anything on surface of the equipment. The object may fall and cause an injury. Also, if metal objects such as needles or clips fall into the equipment, or if liquid is spilled, it may result in a fire or electric shock. Do not hit or drop the equipment. It may be damaged if receiving a strong jolt. If the equipment is used without being repaired, it may result in a fire or electric shock. Do not place excessive weight on the detector. The internal image sensor may be damaged and it can affect to the image quality. Have the patient take a fixed posture and do not let him or her touch parts unnecessarily. If the patient touches connectors or switches, it may result in electric shock or malfunction of the equipment. Do not spill liquid or chemicals onto the detector. In cases where the patient is injured, protect the equipment with a disposable covering not allow to come in contact with blood or other body fluids. Otherwise, it may result in a fire or electric shock. For safety reasons, be sure to turn OFF the power of the equipment when the inspections indicated in this manual are going to be performed. Do not submerge the detector in water. Be sure to use the detector on a flat surface so it will not bend. Otherwise, the internal image sensor may be damaged. Be sure to securely hold the detector while using it in upright positions. Because the equipment cable is long, take care that cables do not become tangled during use. Also, be careful not to get your feet caught in the cable. It may cause a malfunction of the equipment or injury to the user from tripping over the cable. Rev.1.0 Page 14 of 151 VW40-153-006 Do not block the ventilation ports of SCU to prevent overheating. Overheating can cause products malfunctions and damages. VIVIX-S 1717N User Manual 1.3.4 Battery Pack and Charger Do not use the battery pack as a power source for equipment other than VIVIX-S 1717N detector. Be sure to use only the dedicated battery pack for the VIVIX-S 1717N detector. The battery charger is designed for the dedicated battery pack. Do not use the battery charger other than the dedicated one. Otherwise, a battery explosion or a battery leak may occur, resulting in fire or electrical shock. Do not operate the battery charger using any type of power supply other than the one indicated on the rating label. Do not handle the product with wet hands. Do not attempt to disassemble, alter, or apply heat to the product. Avoid dropping or subjecting the product to severe impacts. To avoid the risk of injury, do not touch the internal parts of the battery if it has been cracked. Stop using the battery pack immediately if it emits smoke, a strange smell, or otherwise behaves abnormally. Do not let the battery pack and battery charger come into contact with water or other liquids and do not allow them to get wet. Do not clean with substances containing organic solvents such as alcohol, benzene, thinner, or other chemicals. Otherwise, fire or electrical shock may result. Do not allow dirt or metal objects (such as hair pins, clips, staples or keys) to contact the terminals. Otherwise, battery explosion or leakage of electrolyte may occur, resulting in fire, injury or pollution of surrounding area. If the battery leaks and the electrolytes come into contact with your eyes, mouth, skin or clothing, immediately wash it away with running water and seek medical attention. Do not leave, store, or place the product in a location near heat sources, or in a place subject to direct sunlight, high temperature, high humidity, excessive dust, or mechanical shock. Otherwise, battery leakage, overheating or damage to the product may occur, resulting in electrical shock, burns, injury or fire. Do not attempt to use a battery pack that has deteriorated. Using a battery pack that has exceeded its life cycle may lead to overheating, fire or explosion. The Lithium ion battery is recyclable. Battery slowly discharges even if not in use. The battery pack may have expired if it discharges immediately after being fully charged. You can purchase an optional battery pack to replace an exhausted one. The battery pack is a consumable item. If a fully charged battery is consumed quickly, use a new and fully charged battery pack. Be sure to charge the battery periodically (once a year) if it is not used for an extended period of time. The battery pack cannot be charged if it has been over discharged. Before discarding the battery pack, cover the terminals with adhesive tape or other insulators. Contact with other metal materials may cause fire or explosion. Rev.1.0 Page 15 of 151 VW40-153-006 1.3.5 Environment of Use VIVIX-S 1717N User Manual Do not install the equipment in any of the locations listed below. Doing so may result in failure or malfuction, equipment falling, fire, or injury. Close to facilities where water is used. Where it will be exposed to direct sunlight Close to the air outlet of an air-conditioner or ventilation equipment Nearby the electric heating applicance such as a heater Where the power supply is unstable In a dusty environment In a saline or sulfurous environment Where temperature or humidity is higher than the operating temperature Where there is freezing or condensation In areas prone to vibration On an incline or in an unstable area This product may malfunction due to electromagnetic interference (EMI) caused by telecommunication devices, transceivers, electronic devices, etc. To prevent the electromagnetic wave from badly influencing the product, be sure to avoid placing it in close proximity to the product. Or, change direction or position of the product or move into the shielded place to reduce electromagnetic interference. This equipment is not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide. Conductive fluids that drain into the active circuit components of the system may cause short circuits that can result in electrical fire. Therefore, do not place fluids or food on any part of the system. To avoid electric shocks and burns caused by use of the wrong type of fire extinguisher, make sure that the fire extinguisher at the site has been approved for use on electrical fires. The battery charger and SCU (System Control Unit) cannot be used in patients vicinity. Rev.1.0 Page 16 of 151 VW40-153-006 1.3.6 Problem Management VIVIX-S 1717N User Manual Should any of the following occur, immediately turn OFF the power to each piece of equipment, unplug the power cord from the AC outlet, and contact sales representative or distributor. When there is smoke, an odd smell or abnormal sound no period. When liquid is spilled into the equipment or a metal object is entered through an opening. When the equipment has been dropped and is damaged. 1.3.7 Maintenance and Inspection Do not use or store the equipment near flammable chemicals such as acetone, benzene, thinner, etc. If chemicals are spilled or evaporated, it may result in a fire or electric shock through contact with electric parts inside the equipment. If any flammable cleaning agent is used for the product, be sure to take care when using them. When the equipment is going to be cleaned, be sure to turn OFF the power of the equipment and unplug the power cord from the AC outlet. Never use thinner, acetone, benzene or any other flammable cleaning agent. Otherwise, it may result in a fire or electric shock. Clean the plug of the power cord periodically by unplugging it from the AC outlet and removing dust or dirt from the plug, its periphery, and AC outlet with a dry cloth. If the cord is kept plugged in for a long time in a dusty, humid or sooty place, dust around the plug will attract moisture, and this could cause insulation failure that could result in a fire. Be sure to turn OFF the power of the equipment while cleaning. Otherwise, a fire or electric shock may occur. Rev.1.0 Page 17 of 151 VW40-153-006 1.4 Product Usage Guide VIVIX-S 1717N User Manual When using the equipment, take the following precautions. Otherwise, problems may occur and the equipment may not function correctly. 1.4.1 Calibration To ensure optimal system performance, it is important to verify that the system is calibrated correctly. Check if the calibration is performed after the equipment is completed to be installed or repaired. Do not try to use the system if the calibration has not been performed. If it is difficult to perform the calibration directly, use the calibration data in the detector. The calibration result can be different by the use environment. Therefore, if the result performed with the calibration data in the detector is not satisfied, you can create the data at the field in person by using VIVIX Setup, the calibration software. 1.4.2 Length Measurement Before taking any length measurement on an image, carry out the length calibration with a reference object and verify its results for correct measurement. 1.4.3 Left/Right Marker The operator is responsible for making a correct and clear mark on the left or right side of the image. The software includes a function to mark the image with L (left) or R (right) while acquiring the image through printing and archiving. Prepare an alternative way to prevent any confusion if the operator does not choose to use L/R marks. 1.4.4 Image Backup To avoid missing images which might result in a patient being exposed to additional dose of radiation, it is important to send images to PACS or backup images by using film or external storage media (CD, DVD, HDD, USB). If the hard disk of your workstation is about to be full, the operator should backup images to somewhere else and delete them to make storage (memory) space in the hard disk for new patients. The image backup should be done as a routine operation for every patient and image. Rev.1.0 Page 18 of 151 VW40-153-006 1.4.5 Use Limitations VIVIX-S 1717N User Manual Vieworks software has the engineer mode operated by inputting the administrator password only. This mode should be operated by the person who is qualified by Vieworks. 1.4.6 Disposal Disposal of this product in an unlawful manner may have negative effects on human health and the environment. Be sure to follow the procedure which is in conformity with the laws and regulations applicable in your area. 1.4.7 Pediatric Application Every request should be reviewed by a pediatric radiologist prior to beginning the examination to ensure that an appropriate study is being performed. If the technologist notices an unusual request, he or she must contact a radiologist in charge. Examples include orders- a Full Cervical, Thoracic, and Lumbar Spine series. The pediatric radiologist should contact the ordering physician and decide which study is best for the pediatric patient. The technologist should use a proper technique considering the patients size to decrease the radiation dose when he or she acquires diagnostic images. ALL pediatric patients shall be shielded for their X-ray examinations, except for when the shield will obscure the region of interest, as in a pelvic or SI joint X-ray for trauma or arthritis, or when it is physically or clinically unreasonable to shield the patient. For routine Hip X-Rays, ALL male children shall have their scrotum shielded using the small gonadal shield while females may not be shielded because doing so would obscure the hips. To minimize motion in infants and young children, swaddle the infant. Use distraction tools to improve cooperation and projectors with child-friendly themes, music, toys with flashing lights or music, child-
friendly images on the ceiling or walls, singing, counting, and a parent reading and talking to the child through the console all can help reduce anxiety and comfort the child. A scoliosis series will consist of a single frontal standing view of the spine. No lateral view or supine view is needed, unless specifically asked for by the Orthopedist or Radiologist. If the females breasts can be shielded without obscuring the spine, breast shields should be used. 1.4.8 Before Exposure Be sure to check the equipment daily and confirm that it works properly. Sudden heating of the room in cold areas will cause condensation to form on the equipment. In this case, wait until the condensation evaporates before performing an exposure. If the equipment is used while condensation is formed in it, problems may occur in the quality of captured images. When an air-conditioner is used, be sure to raise/lower the temperature gradually so that difference between the temperature in the room and in the equipment does not occur, to prevent condensation. Rev.1.0 Page 19 of 151 VW40-153-006 1.4.9 During Exposure VIVIX-S 1717N User Manual This equipment is not protected (sealed) against liquids such as blood and medicine in the operating room. If necessary, wrap the equipment in a disposable cover when using it. Do not use the selected frequency channel (2.4 and 5 dual band) for other wireless devices. Mutual interference may affect the image data transmission rate. Do not use the detector near devices generating a strong magnetic field. Doing so may produce image noise or artifacts. 1.4.10 Operating and Storage Environment This equipment is mainly used in the X-ray exposure room and hospital wards. To use it in other places, consult Vieworks sales representative or a distributor. Do not expose this equipment to high temperatures and/or high humidity. Malfunctions may occur. When not in use, keep the products in a safe location. Be sure to use and store this equipment under the conditions described below. Classification Temperature Humidity (Non-condensing) Atmosphere Operating Environment
+10 ~ +35 Storage Environment
-15 ~ +55 30 ~ 85%
10 ~ 90%
700 1060 hPa 500 1060 hPa 1.4.11 Others Do not use this equipment in combination with peripherals such as defibrillators or large electric motors as these may cause power-supply noise or power supply voltage variations. Doing so may prevent normal operation of this equipment and peripherals. Rev.1.0 Page 20 of 151 VW40-153-006 VIVIX-S 1717N User Manual This section gives an instruction about the product components and their specifications. 2. Product Overview Product Components VIVIX-S 1717N Detector SCU Basic (FXRS-02A) SCU Basic (FXRS-03A) SCU mini (FXRS-04A) Battery Pack Battery Charger Others Rev.1.0 Page 21 of 151 VW40-153-006 2.1 Overview VIVIX-S 1717N User Manual VIVIX-S 1717N detector is the digital X-ray imaging solution. It acquires images by exposing X-ray which has been penetrated the human body. When X-ray photons pass through scintillator in the detector, the photons convert to visible ray, and the visible ray is converted to electronic signals through TFT (a-Si). Then the detector digitalizes x-ray images and transfers them to the computer (workstation) for radiography diagnostics. Users can perform image diagnosis easily through the image display monitor with this process. Advanced digital image processing also allows considerably efficient diagnosis, all kinds of information management, and sharing of image information on network. This detector is used for the general-purpose diagnostic procedures, and it is intended to replace radiographic film / screen systems. This detector is not intended for mammography applications. 2.1.1 Features Since VIVIX-S 1717N detector is compatible with a conventional film cassette, it enables to replace the analog radiographic diagnosis (Supporting ISO4090 standard). The new sensor with 124m pixel pitch produces high spatial resolution (approx. 5.2 Mega pixels) digital images. Various applications such as neonatal, ENT, equine and cephalo Choose between two scintillator types (CsI and Gadox) of detector provided by Vieworks. The built-in wireless communication supports IEEE 802.11n to acquire images without a wired connection in anytime, anywhere. Make direct wireless communication with the built-in wireless AP function. (Inside APTM) Supports the stable and reliable AED (Auto Exposure Detection) function. (AnytimeTM) Designed as lightweight and thin with portability to allow easy exposure in anytime, anywhere. Used in various ways for infant / animals and in the dental clinic / ENT, etc. Rev.1.0 Page 22 of 151 VW40-153-006 2.2 Product Components 2.2.1 Detector VIVIX-S 1717N User Manual Component Model / Description VIVIX-S 1717N Wireless Detector FXRD-1717NAW (4.5kg) FXRD-1717NBW (4.5kg) FXRD-1717NA (4.2kg) FXRD-1717NB (4.2kg) VIVIX-S 1717N Wired Detector A deco sheet attached on the detector can be different depending on each client company. 2.2.2 SCU (System Control Unit) Component Model / Description SCU Basic
(FXRS-02A) SCU Basic
(FXRS-03A) FXRS-02A (2.5kg) AC Power Cable (2m) 110V (1EA) / 220V (1EA) FXRS-03A (2.8kg) AC Power Cable (2m) 110V (1EA) / 220V (1EA) Rev.1.0 Page 23 of 151 VW40-153-006 VIVIX-S 1717N User Manual FXRS-04A (1.2kg) DC Power Supply (24V) AC Power Cable (2m) 110V (1EA) / 220V (1EA) You can choose the type of SCU depending on the purpose of use. SCU mini
(FXRS-04A) 2.2.3 Battery & Charger Component Description Battery FXRB-02A (0.12kg, 4EA) FXRC-02A (0.8kg) DC Power Supply (24V) AC Power Cable (2m) 110V (1EA) / 220V (1EA) Page 24 of 151 VW40-153-006 Charger Rev.1.0 2.2.4 Accessories VIVIX-S 1717N User Manual Component Description Resource Software (Viewer or SDK) Manuals Tether Interface Cable (7m) Ether Con Cable (7m, Option) Generator Interface Cable (15m) UTP LAN Cable (15m, Direct) CAT 5E or CAT6 Cables The use of accessories and cables other than those approved and sold by Vieworks Co., Ltd. may result in increased release of electromagnetic waves or decreased stability of the equipment. Accessory equipment connected to the analog and digital interfaces must be certified according to the respective IEC standards. All combinations of equipment must be in compliance with IEC 60601-1-1 system requirements. Any person who connects additional equipment to the signal input or signal output ports configures a medical system, and is therefore responsible for ensuring that the system complies with the requirements of the system standard IEC 60601-1. Consult your sales distributor or manufacturer if you have any concerns. Rev.1.0 Page 25 of 151 VW40-153-006 2.3 VIVIX-S 1717N Detector VIVIX-S 1717N User Manual VIVIX-S 1717N is designed to acquire digital images by collecting x-ray signals and sereval conversion processes. You can use the acquired image (17 x 17 film size) diversely depending on the purpose of use. VIVIX-S 1717N is one of the VIVIX detector models produced by Vieworks. 2.3.1 Specifications Item Model Specifications FXRD-1717NA (CsI) FXRD-1717NB (Gadox) FXRD-1717NAW (CsI) FXRD-1717NBW (Gadox) Image Sensor TFT: a-Si (Amorphous Silicon) X-ray Scintillator Type Pixel Pitch Field of View FXRD-1717NA(W) : Csl: TI (Thallium doped Caesuim Iodide) FXRD-1717NB(W) : Gd2O2S:Tb (Gadolinium oxysulfide) 0.14 (140) 17 x 17 Active Area (H x V) 430.08 430.08 Active Array Effective Area Effective Array Grayscale 3072 x 3072 pixels 428.4 x 428.4 3060 x 3060 Pixels 16 bit Spatial Resolution Min. 3.5 lp/
Image Acquisition Time (Wired) 1.5 sec. Image Acquisition Time (Wireless) 3 sec. Recommended Cycle Time 15 sec. X-ray Synchronization Control AED (Auto Exposure Detection) DR Trigger (External line trigger) DC +24V, Max. 1.0A Rated Power Supply Wired: Powered by SCU with a tether interface cable. Wireless: Powered by a battery pack (3,100 h X 2) Power Consumption Max. 24W Dimensions (H W D) 460 460 15.5 Weight 4.2kg (Wired) 4.5kg (Wireless / including a battery pack) Wired: Gigabit Ethernet (1000BASE-T) via PoE (Power over Image Transfer Ethernet) Wireless: IEEE802.11n Data Transmission Rate (Wired) Max. 1Gbps Data Transmission Rate (Wireless) Max. 300Mbps (MIMO 2X2) Rev.1.0 Page 26 of 151 VW40-153-006 2.3.2 Drawing Sheet VIVIX-S 1717NAW / 1717NBW (Wireless Detector) VIVIX-S 1717N User Manual Item Description Dimensions (H W D) 460.0 460.0 15.5 Curvature of Edges R6.5 Under the ISO4090 regulation, the allowed tolerance of a thickness of detector is from -
2 ~ +1. Rev.1.0 Page 27 of 151 VW40-153-006 VIVIX-S 1717NA / 1717NB (Wired Detector with a tether interface cable) VIVIX-S 1717N User Manual Item Description Dimensions (H W D) 460.0 460.0 15.5 Curvature of Edges R6.5 Under the ISO4090 regulation, the allowed tolerance of a thickness of detector is from -
2 ~ +1. Rev.1.0 Page 28 of 151 VW40-153-006 2.3.3 Functions VIVIX-S 1717NAW / 1717NBW (Wireless) Name Description VIVIX-S 1717N User Manual A Tether interface connector Used for tighten the tether interface cable. Used for wired connection between a detector and SCU. B C D Tether interface holder Fix/release holder of the tether interface cable. Battery lock lever Lock/unlock lever of the equipped battery pack. Antenna for wireless LAN Antennas for wireless communication (2EA) E Status indicator Detector status indicator DATA LED (Blue): Indicates communication and transmission ACTIVE LED (Orange): Indicates ready to work POWER LED (Green): Indicates power On/Off status Power button Detector power button AP ON /OFF Button Turns on / off the AP mode. Battery Remaining LED Notices the remaining of battery in 5 levels. F G H Rev.1.0 Page 29 of 151 VW40-153-006 VIVIX-S 1717N User Manual VIVIX-S 1717NA / 1717NB (Wired) A B Name Description Tether interface connector Used for tighten the tether interface cable. Used for wired connection between a detector and SCU. Tether interface holder Fix/release holder of the tether interface cable. C Status indicator Detector status indicator DATA LED (Blue): Indicates communication and transmission ACTIVE LED (Orange): Indicates ready to work POWER LED (Green): Indicates power On/Off status D Power button Detector power button Rev.1.0 Page 30 of 151 VW40-153-006 2.3.4 Deco Sheet VIVIX-S 1717NAW / 1717NBW (Wireless) VIVIX-S 1717N User Manual A B C D E Indication Info. Description Wireless communication logo Applied to VIVIX-S 1717NAW / 1717NBW. Status indication logo Indicates the operating state of detector. AP Mode, DATA, ACTIVE, POWER Image starting point Indicates the starting point of an original image. Center of the detector Indicates the central position of detector. Certification logo Indicates the certification logos relating to a medical device. Image starting point (0.0) of this detector is located nearby the tether interface connector. You can change the displayed direction of an image from the VIVIX Setup program, but it does not mean that the starting point and direction of the original image are changed. Rev.1.0 Page 31 of 151 VW40-153-006 VIVIX-S 1717NA / 1717NB (Wired) VIVIX-S 1717N User Manual Indication Info. Description Status indication logo Indicates the operating state of detector. DATA, ACTIVE, POWER Image starting point Indicates the starting point of an original image. Center of the detector Indicates the central position of detector. Certification logo Indicates certification logos relating to a medical device. A B C D Rev.1.0 Page 32 of 151 VW40-153-006 VIVIX-S 1717N User Manual 2.3.5 Wireless Communication Item Specifications Wireless standard IEEE802.11n 2.412 ~ 2.472 (13 Channels) Frequency range 5.18 ~ 5.24 (4 Channels) 5.745 ~ 5.805 (4 Channels) Data transmission rate 802.11n: Max. 300Mbps (MIMO 2X2) Modulation BPSK, QPSK, 16-QAM, 64-QAM Transmission power Max. 17dBm Security Antenna WPA2-PSK Dual Band Antennas (2EA, inbuilt) The specification of detector and SCU are same, but the location of antenna is different. 2.3.6 Use Environment Item Operation Storage & Transportation Temperature
+10 ~ +35
-15 ~ +55 Humidity 30 ~ 85% (Non-condensing) 10 ~ 90% (Non-condensing) Atmospheric pressure 700 ~ 1060 hPa 500 ~ 1060 hPa Shock Vibration 1.6G 0.7G 20G 0.7G The use environment of detector and SCU is same. Load Limit of Detector Uniform load Local load Over the whole surface Center diameter 40mm Max. 150 kg Max. 100 kg Rev.1.0 Do not let the paitent or object heavier than load limit be on the detector. Then, detector can be damaged. Do not let the patient lie or get on the detector. Internal devices such as a sensor can be seriously damaged even if his/her weight is within the load limit. Page 33 of 151 VW40-153-006 2.4 SCU Basic (FXRS-02A) VIVIX-S 1717N User Manual SCU Basic synchronizes the image and X-ray signal as locating among the detector, workstation and the X-
ray generator. You can use the SCU directly when the power supplies to SCU after connecting it under the VIVIX-S 1717N system environment. 2.4.1 Specifications Item Model Power Supply Cable Connection port Specifications FXRS-02A Input: AC100 to 240V, 50/60, Max. 2.0-0.8A Output: DC +24V 3.25A, 78W Gigabit Ethernet ports (3ea) Two(2) PoE (Power over Ethernet) ports Dimension (H W D) 210.0 300.0 54.2 Weight 2.5 2.4.2 Drawing Sheet Rev.1.0 Page 34 of 151 VW40-153-006 2.4.3 Functions Front Side VIVIX-S 1717N User Manual No. Name Description Power Switch SCU power swtich (ON or OFF) (Including green LED Lamp) Fan Expels interior air of SCU 1 2 Rear Side No. Name 1 2 EXT_INF1 EXT_INF2 LAN port
(Port 1, 2, 3) Description X-ray generator interface connector (D-SUB 15 pins x 2 EA, Female) EXT_INF1 : 1 ~ 15 EXT_INF2 : 16 ~ 30 Gigabit Ethernet port (1000BASE-T) Port 1: Communicates between workstation and SCU Basic. Port 2, 3: Communicates between FXRD-1717S detector and SCU Basic when configuring multiple detectors. Indicates the status of PoE port (Port 4, Port 5) 3 PoE status lamp Green: 1 Gbps Orange: 100 Mbps Rev.1.0 Page 35 of 151 VW40-153-006 4 PoE port
(Port 4, 5) 5 Detector power supply port 6 P.E 7 AC input port VIVIX-S 1717N User Manual PoE (Power over Ethernet) port (1000BASE-T) Communicates between the detector and SCU Basic. Supplies power to the detector. Max. DC +24V/15W (2 ports) For FXRD-1717S detector only. Equipotential ground T2AL250V fuse (2 EA) 100 ~ 240V 50/60 Supplies power to SCU Basic. The P.E (Potential Equalization) port of SCU is used to maintain potential equalization between SCU and another grounded system. Use the conductor that can be detached without the use of a tool. Rev.1.0 Page 36 of 151 VW40-153-006 2.5 SCU Basic (FXRS-03A) VIVIX-S 1717N User Manual SCU Basic synchronizes the image and X-ray signal as locating among the detector, workstation and the X-
ray generator. You can use the SCU Basic directly when the power supplies to SCU Basic after connecting it under the VIVIX-S 1717N system environment 2.5.1 Specifications Item Model Power supply Cable connection port Specifications FXRS-03A Input: AC100 to 240V, 50/60, Max. 2.0-0.8A Output: DC +24V 3.25A, 78W Gigabit Ethernet port (3EA) PoE (Power over Ethernet) Port (2EA) Wireless communication IEEE 802.11n (2.4 / 5 ) Dimension (H W D) 236.0 300.0 58.0 Antenna Weight 140 (2EA, Dual band) 2.8 2.5.2 Drawing Sheet Rev.1.0 Page 37 of 151 VW40-153-006 2.5.3 Functions Front Side VIVIX-S 1717N User Manual No. Name Description 1 2 3 Power switch Turns on/off the power of SCU Basic. (Including Green LED Lamp) Fan Antenna Expels the air inside of SCU Basic. Assists communications between the detector and SCU Basic. Indicates the operation and connection status of SCU Basic. 4 Status LED Blinking green: Booting Green: Completed to boot up Blue: The software is connected and ready to communicate. Rev.1.0 Page 38 of 151 VW40-153-006 Rear Side VIVIX-S 1717N User Manual No. Name 1 2 EXT_INF1 EXT_INF2 LAN port
(Port 1, 2, 3) Description X-ray generator interface connector (D-SUB 15 pins x 2 EA, Female) EXT_INF1 : 1 ~ 15 EXT_INF2 : 16 ~ 30 Gigabit Ethernet port (1000BASE-T) Port 1: Communicates between workstation and SCU Basic. Port 2, 3: Communicates between FXRD-1717S detector and SCU Basic when configuring multiple detectors. Indicates the status of PoE port (Port 4, Port 5) 3 PoE status lamp Green: 1 Gbps 4 PoE port
(Port 4, 5) 5 Detector power supply port 6 P.E 7 AC input port Orange: 100 Mbps PoE (Power over Ethernet) port (1000BASE-T) Communicates between the detector and SCU Basic. Supplies power to the detector. Max. DC +24V/15W (2 ports) For FXRD-1717S detector only. Equipotential ground T2AL250V fuse (2 EA) 100 ~ 240V 50/60 Supplies power to SCU Basic. Rev.1.0 The P.E (Potential Equalization) port of SCU is used to maintain potential equalization between SCU and another grounded system. Use the conductor that can be detached without the use of a tool. Page 39 of 151 VW40-153-006 2.6 SCU mini (FXRS-04A) VIVIX-S 1717N User Manual SCU mini synchronizes the image and X-ray signal as locating among the detector, workstation and the X-
ray generator. You can use the SCU mini directly when the power supplies to SCU mini after connecting it under the VIVIX-S 1717N system environment 2.6.1 Specifications Item Model Specifications FXRS-04A Power supply Input: DC +24V 2A Max Cable connection port Gigabit Ethernet port (3EA) PoE (Power over Ethernet) Port (1EA) Wireless communication IEEE 802.11n (2.4 / 5 ) Dimension (H W D) 210.0 170.0 45.0 Antenna Weight 140 (2EA, Dual band) 1.2 2.6.2 Drawing Sheet Rev.1.0 Page 40 of 151 VW40-153-006 VIVIX-S 1717N User Manual 2.6.3 Functions Front Side No. Name Description 1 2 Power switch Turns on/off the power of SCU mini. Antenna Assists communications between the detector and SCU mini. Indicates status of SCU mini operation and connection. 3 Status LED Blinking green: Booting Green: Completed to boot up Blue: The detector is connected and ready to communicate. Rev.1.0 Page 41 of 151 VW40-153-006 Rear Side VIVIX-S 1717N User Manual No. Name 1 EXT_INF Description X-ray generator interface connector (D-SUB 15pin, Female) Gigabit Ethernet port (1000BASE-T) 2 LAN port
(Port 1, 2, 3) Port 1: Communication between the workstation and SCU mini. Port 2, 3: Communication between FXRD-1717S detector and SCU mini when configuring multiple detectors. Indicats the status of PoE port. 3 PoE status lamp Green: 1 Gbps Orange: 100 Mbps PoE (Power over Ethernet) port (1000BASE-T) 4 PoE port Communication between the detector and SCU mini. 5 DC power input port Supplies power to the detector. DC +24V Supplies power to SCU mini. Rev.1.0 Page 42 of 151 VW40-153-006 2.7 Battery Pack 2.7.1 Specifications VIVIX-S 1717N User Manual Item Model Type Specifications FXRB-02A Lithium Ion Rated Power Supply Output: DC +7.6V Capacity 3,100h Number of cell 2S1P (2 Series 1 Parallel) Life Approx. 500 times (Fully charged/Discharged completely, 1cycle) Dimension (H W D) 160.0 61.8 5.7 Weight 115g 2.7.2 Drawing Sheet Rev.1.0 Page 43 of 151 VW40-153-006 VIVIX-S 1717N User Manual 2.8 Battery Charger 2.8.1 Specifications Item Model Specifications FXRC-02A Simultaneous Charging 2 battery packs Charging time 3 hours Rated power supply DC +24V, 2A Max. Dimension (H W D) 192.0 101.0 26.0 Weight 0.8 2.8.2 Drawing Sheet No. Name Description 1 2 Rev.1.0 Top / Bottom LED Indicates the position and status of a battery being charged. Power input port Supplies electric power by connecting a power adapter to the battery charger. Page 44 of 151 VW40-153-006 2.9 Others VIVIX-S 1717N User Manual 2.9.1 X-ray Generator (Recommended Exposure Condition) Item Recommended condition X-ray energy range 40kVp ~ 150kVp Reliability (Lifetime Dose) 74Gy or higher (35 uGy x 365days x 24hrs x 60min. x 60sec. / 15sec.) 2.9.2 Recommended Specifications of Workstation (PC) Item Recommended specification VIVIX Setup Microsoft Windows 7 (32bit / 64bit) Operating System Microsoft Windows Vista Service pack 1 or higher (32bit / 64bit) Microsoft Windows 7 64bit SP1 (Professional Edition or higher) Microsoft Windows 8 (32bit / 64bit) / 8.1 64bit SP1 (Professional CPU Memory Hard Disk Edition or higher Microsoft Windows 8.2 (32bit / 64bit) Intel Core i5 2600 or higher (or compatible CPU) 4GB or higher 1TB or higher Gigabit (for detector only) Intel PRO 1000 Series (Gigabit LAN Card for network interface) LAN Card (only for Min.requiremetns detector communication) Speed: 1Gbps or more Jumbo Frames: 9K Receive Descriptors: 2K (1024 or higher) Monitor CD-ROM 1024 x 768 or more CD or DVD R/W 2.9.3 Recommended Specifications of Grid Item SID Size Ratio Frequency Recommended specification 100cm / 130cm / 150cm / 180cm 451mm x 365mm x 1.5mm 8.1 / 10:1 / 12:1 215 line/inch INTER SPACER AL Check the recommended specifications by Vieworks first before buying the generator, workstation and grid. Rev.1.0 Page 45 of 151 VW40-153-006 VIVIX-S 1717N User Manual 3. System Configuration This section gives information about the various connection / configuration ways among the You can figure out the most suitable way of system configuration through this instruction. detector, SCU, workstaton and X-ray generator. Detector Connection Method Diagram System Configuration Generator Interface Rev.1.0 Page 46 of 151 VW40-153-006 VIVIX-S 1717N User Manual 3.1 Detector Connection Methods You can organize wired or wireless connection between the VIVIX-S 1717N detector and SCU. You can also choose other connection ways suitable for the use environment in case of need. 3.1.1 Wireless Connection The images and data are transmitted between the VIVIX-S 1717N detector and SCU by wireless connection. A battry pack should be installed in the detector to use it under the wireless configuration. We recommend you to use the wireless connection method for the following cases. When using the unfixed detector. When the wired communication is in trouble by the interruption of cables. The wireless connection is more freely to operate than the wired connection. Use the wireless connection with a laptop computer to enhance mobility. Be sure to operate the wireless commnunication between the detector and SCU within a maximum of 8m. Use of multiple WLAN devices within the same frequency band may interfere with each wireless communication and cause a decline in transmission speed. Do not cover or block the wireless module of the detector. Also, do not put any shielding materials between the detector and SCU. Otherwise, the transmission speed or operable distance may be reduced. Rev.1.0 Page 47 of 151 VW40-153-006 3.1.2 Wired Connection VIVIX-S 1717N User Manual Connect VIVIX-S 1717N detector and SCU with a tether interface cable to make a wired configuration. As the tether interface cable supplies power to the detector, a battery pack is not needed to be installed in the detector. We recommend you the wired connection method for the following cases. When continuous power supply to the detector is needed. When the detector is fixed in a bucky stand or on a table. When you upgrade the detector firmware or change the inner configural information. When you need the data communication to be faster than the wireless connection. A battery pack in the detector keeps charging under the wired connection. The wireless communication module of the detector maintains inactivation status. Rev.1.0 Page 48 of 151 VW40-153-006 3.2 Diagram 3.2.1 Block Diagram VIVIX-S 1717N User Manual 3.2.2 Wiring Diagram Rev.1.0 Page 49 of 151 VW40-153-006 3.3 System Configuration VIVIX-S 1717N User Manual This section gives information about the configuration modes of VIVIX-S 1717N detector, SCU, workstation and the generator. 3.3.1 AP Mode (SCU AP Mode) SCU AP mode is the wireless connection method that connecting the detector with SCU as the center wirelessly. SCU & Detector The VIVIX-S 1717N detector and SCU are connected wirelessly. In this case, SCU and the detector operate as AP (Access Point) and STATION respectively. SCU & PC (Workstation) SCU and PC (Workstation) are connected with the LAN cable. It is available to connect SCU and PC wirelessly. In this case, SCU and the detector operate as AP (Access Point) and STATION respectively. SCU & Generator Rev.1.0 SCU and the generator can be connected with the generator interface cable. It is unnecessary to connect SCU and the generator with a generator interface cable if you use AED mode of the detector. Page 50 of 151 VW40-153-006 3.3.2 Tether Interface Mode VIVIX-S 1717N User Manual Tether interface mode is the wired connection method that connecting the detector with SCU as the center. SCU & Detector SCU and the VIVIX-S 1717N detector are connected with the tether interface cable. Other connection ways of the tether interface mode are the same as the AP mode. Rev.1.0 Page 51 of 151 VW40-153-006 3.3.3 External AP Mode VIVIX-S 1717N User Manual External AP mode is the wireless connection method that adding the external AP device instead of SCU. External AP & SCU The external AP and SCU are connected with a LAN cable. External AP & Detector The external AP and VIVIX-S 1717N detector are connected wirelessly. In this case, the external AP and the detector operate as AP (Access Point) and STATION respectively. Other connection ways of the tether interface mode are the same as the AP mode. Be sure to check the specifications of external AP device when configuring the external AP mode, since the wireless communication performance can be different by the specifications. Rev.1.0 Page 52 of 151 VW40-153-006 3.3.4 Detector AP Mode VIVIX-S 1717N User Manual Detector AP mode is the wireless connection method that connecting the PC (Workstation) with the detector as the center wirelessly. Detector & PC (Workstation) The VIVIX-S 1717N detector and PC are connected wirelessly. In this case, the detector and the PC operate as AP (Access Point) and STATION respectively. Since SCU is not used for configuring the detector AP mode, you can only use the AED mode without a wired connection. (Cannot use the DR Trigger mode.) This mode can be used when mobility and portability are needed. When configuring the detector AP mode, be sure to check the specifications of wireless module installed in the PC. The wireless communication performance can be different depending on the specifications of the wireless module. If the wireless connection cannot be made normally because of unexpected problems, SCU can be needed to check the detector condition. Rev.1.0 Page 53 of 151 VW40-153-006 VIVIX-S 1717N User Manual 3.3.5 Detector Stand-Alone Mode You can use the Stand-Alone mode without making a wired or wireless connection. You should take images with the AED mode only when using the Stand-Alone mode.
(Cannot use the DR Trigger mode.) The acquired images are stored in the internal storage of the detector in order and the images can be transmitted to the PC after connecting the detector to the PC. The transmitted images are removed automatically from the detector. Rev.1.0 Page 54 of 151 VW40-153-006 3.4 Generator Interface VIVIX-S 1717N User Manual VIVIX-S 1717N detector provides DR Trigger interface and AED interface as a generator interface way to acquire images by detecting X-ray. Interface Description AED The detector detects X-ray exposure from the generator automatically and then performs image acquisition without any cable connection. The detector and generator receive and send their signal to each other for image DR Trigger acquisition. SCU and X-ray generator should be connected with the generator interface cable. 3.4.1 AED (Auto Exposure Detection) Interface If the VIVIX-S 1717N detector is used as the AED interface, you can acquire images without connecting the generator to the detector with a generator interface cable. Cautions when using AED interface Make sure to follow the operating environmental condition (Temp: +10 ~ +35). Do not give impact to the product. If it receives strong jolt, unwanted images may be acquired without the X-ray exposure because of the malfunction of the AED sensor. You may not acquire images or horizontal artifacts may occur depending on the external environment such as exposure condition, thickness of object or the use of grid. When you set X-ray exposure area to the direction of the detector, the center of the detector should be involved in the X-ray exposure area. Otherwise, you may not acquire an image. Rev.1.0 Page 55 of 151 VW40-153-006 3.4.2 DR Trigger Interface VIVIX-S 1717N User Manual Connect the detector and X-ray generator with a generator interface cable, and then acquire images by sending and receiving their signal. Signal Processing Steps 1 The detector receives EXP_REQ signal from the X-ray generator. 2 After the detector completes to prepare image acquisition, it sends the EXP_OK signal to the X-ray generator. The X-ray generator confirms EXP_OK signal and generates X-rays. The detector acquires images and then transmits the image data. EXP_REQ is a sending signal from X-ray generator to the detector for requesting exposure. EXP_OK is an exposure ready signal from the detector to X-ray generator. 3 4 Rev.1.0 Page 56 of 151 VW40-153-006 VIVIX-S 1717N User Manual 3.5 Configuring DR Trigger Interface To configure the DR Trigger interface, SCU and the generator should be connected with a generator interface cable. Connect the one end of generator interface cable to EXT_INF port of SCU, and then connect the other end to the generator. Up to three generators can be connected with SCU Basic. Only one generator can be connected with SCU mini. 3.5.1 Trigger Interface Way The generator interface cable is connected differently depending on the of trigger interface ways. Trigger Interface Description Packet Trigger Handles exposure signal by exchanging packet. Line Trigger Handles exposure signal by exchanging electrical signal. 3.5.2 Packet Trigger Multipe detectors share one generator signal together. Connect a generator interface cable to one of the pin groups. The generator tramsmits and receives signal with the one selected detector for taking images. Rev.1.0 Page 57 of 151 VW40-153-006 VIVIX-S 1717N User Manual Each detector shares a signal signal by being connected with generators separately. Up to three X-ray generators can be connected to SCU. The connection of each detector and generator can be configured from VIVIX Setup. You should comprehend about a detector and X-ray generator to make correct exposure. Otherwise, X-ray can be exposed to the detector in different location. The engineer who understand the generator device and interface technology should be in charge of interface work between SCU and the generator. 3.5.3 Line Trigger Rev.1.0 Page 58 of 151 VW40-153-006 3.5.4 EXT_INF Port Pin Map VIVIX-S 1717N User Manual EXT_INF port is D-SUB 15 pin female connectors of SCU, and used for the generator interface. Product EXT_INF port SCU Basic (FXRS-03A) SCU mini (FXRS-04A) EXT_INF1 port pin map definition (1 ~ 15) No. Signal name I/O Type Color Ch. Description EXP_REQ+_A Input Contact Red EXP_REQ-_A Input Contact Black EXP_REQ_TTL_A Input TTL Orange EXP_REQ_GND_A Input TTL Gray A A A A Receives EXP_REQ Returns signal from EXP_REQ+_A Receives EXP_REQ Returns signal from EXP_REQ_TTL_A EXP_OK_POWER_A/B Input EXP_OK+_A EXP_OK-_A EXP_OK+_B EXP_OK-_B Reserved Output Output Output Output
-
-
-
-
-
-
-
EXP_REQ+_B Input Contact White EXP_REQ-_B Input Contact Purple Yellow A/B Power of TTL signal Green Brown Blue Pink
-
A A B B
-
B B Sends EXP_OK Returns signal from EXP_OK+_A Sends EXP_OK Returns signal from EXP_OK+_B Reserved for test only. Receives EXP_REQ Returns signal from EXP_REQ+_B EXP_REQ_TTL_B Input TTL White/Red B Receives EXP_REQ EXP_REQ_GND_B Input TTL White/Black B Returns signal from EXP_REQ_TTL_B Reserved
-
-
-
-
Reserved for test only. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Rev.1.0 Page 59 of 151 VW40-153-006 EXT_INF2 port pin map definition (16 ~ 30) No. Signal name I/O Type Color Ch. Description VIVIX-S 1717N User Manual EXP_REQ+_C Input Contact Red EXP_REQ-_C Input Contact Black EXP_REQ_TTL_C Input TTL Orange EXP_REQ_GND_C Input TTL Gray EXP_OK_POWER_C Input
-
EXP_OK+_C EXP_OK-_C EXT_W+
EXT_W-
EXT_X+
EXT_X-
EXT_Y+
EXT_Y-
EXT_Z+
EXT_Z-
Output -
Output -
Input Contact Input Contact Input Contact Input Contact Input Contact Input Contact Input Contact Input Contact Yellow Green Brown
-
-
-
-
-
-
-
-
C C C C C C C
-
-
-
-
-
-
-
-
Receives EXP_REQ Returns signal from EXP_REQ+_C Receives EXP_REQ Returns signal from EXP_REQ_TTL_C Power of TTL signal Sends EXP_OK signal Returns signal from EXP_OK+_C User-defined Pin 1 Returns signal from EXT_W+
User-defined Pin 2 Returns signal from EXT_X+
User-defined Pin 3 Returns signal from EXT_Y User-defined Pin 4 Returns signal from EXT_Z+
Since SCU mini has EXT_INF 1 port, only one generator can be connected with. Up to three X-ray generators can be connected to EXT_INF1 and EXT_INF2 ports, and each generator should be connected with a same channel. There are Contact type (OPEN/ CLOSE) and TTL type (ON/ OFF) on the signal in/output pin. TTL type information ON : VCC OFF : GND Current: 5 ~ 10 Voltage: 12 V ~ 24 V When you plan to add interface using a user-defined pin, contact to the person in charge of Vieworks. 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Rev.1.0 Page 60 of 151 VW40-153-006 VIVIX-S 1717N User Manual 3.5.5 Input / Output Circuit Exposure Request Input Circuit (EXP_REQ) Exposure Respond Output Circuit (EXP_OK) Rev.1.0 Page 61 of 151 VW40-153-006 VIVIX-S 1717N User Manual This section gives information about the installation process and method to use a detector. 4. Installation Battery Pack Product Installation Generator Connection Software Installation Windows Environment Setting Rev.1.0 Page 62 of 151 VW40-153-006 4.1 Battery Pack VIVIX-S 1717N User Manual Detector and its attached devices should be installed by an authorized service engineer. If you encounter any problems, consult the sales representative in Vieworks or a relevant engineer. 4.1.1 How to insert a battery pack 1 Open the battery cover. 2 Insert a battery into a slot until it clicks and push the lever to the right for fixing the battery. 3 Close the battery cover. Rev.1.0 Check if the battery is fully charged before using. Make sure that the battery pack is securely inserted. The remaining battery can be checked from the battery lamp on the side of detector or from the VIVIX Setup program. Page 63 of 151 VW40-153-006 4.1.2 How to take out a battery pack VIVIX-S 1717N User Manual 1 Open the battery cover. 2 Push the lever to the left for taking out the battery. 3 Close the battery cover. Rev.1.0 Make sure to turn off the detector by pressing and hold the power button for 3 seconds before detaching a battery pack. All status LED lamps are off and then the detector is turned off. Page 64 of 151 VW40-153-006 VIVIX-S 1717N User Manual 4.1.3 How to charge a battery pack The detector is battery-operated when it is connected wirelessly. Charge the battery pack fully before inserting it to the detector. Charging type 1 Supply power to the charger with the power adapter before charging a battery. 1 Open the cover at the lower side of charger. 2 Put the battery on the top of charger in the right direction. 3 Push the battery down until it is fixed in the charging part. 4 Close the cover at the lower side of charger. Stimultaneous charging Charging time 2 battery packs 3 hrs 4 hrs Battery charger Tether interface cable 1 battery pack Rev.1.0 Page 65 of 151 VW40-153-006 Charging type 2 Supply power to the charger with the power adapter before charging a battery. VIVIX-S 1717N User Manual 1 Open the cover at the lower side of charger. 2 Insert the battery into the slot until it clicks. 3 Close the cover at the lower side of charger. The charging time can be different depending on temperature and charging status of a battery. While charging a battery pack, it is available to use the detector by connecting it with a tether interface cable. This detector is designed to make a battery being discharged little by little during the detector is off. Therefore, remove the battery pack when the detector is not used for some time. Otherwise, over discharge may occur resulting in the shortened battery life. Do not use the charger around the paitent. Charge the battery with the charger provided by Vieworks. Securely plug the power cord of the charger into the AC outlet. If contact failure occurs, or if dust/metal objects come into contact with the exposed metal prongs of the plug, fire or electric shock may result. Stop charging the battery when status LED of the charger turns to green as exceeding the specified charging time. Otherwise, the battery pack is overcharged and it causes smoke. If the battery pack is overheating, it can be exploded and a fire may occur. Use only a power adapter complying with IEC 60601-1 or IEC 60950-1. Rev.1.0 Page 66 of 151 VW40-153-006 4.2 Product Installation 4.2.1 Connecting Devices VIVIX-S 1717N User Manual Installation of this equipment should be made by licensed and authorized personnel by Vieworks. This equipment must only be connected to the power with protective earth. SCU Basic (FXRS-02A) 1 If you use the DR Trigger mode, connect the one end of generator interface cable to the EXT_INF port of SCU, and the other to the X-ray generator. If you use the AED mode, a generator interface cable is not needed as the detector operates by detecting X-ray automatically. 2 Connect one end of the LAN cable to one of the LAN ports of SCU, and the other to the LAN Card Connector of workstation assigned for data transfer. 3 Connect the one end of the Tether Interface cable to the Port 4 or Port 5 of SCU and the other to the detector. 4 To supply power, connect the AC power cable to the AC power input port of SCU. Rev.1.0 Page 67 of 151 VW40-153-006 SCU Basic (FXRS-03A) VIVIX-S 1717N User Manual 1 If you use the DR Trigger mode, connect the one end of generator interface cable to the EXT_INF port of SCU, and the other to the X-ray generator. If you use the AED mode, a generator interface cable is not needed as the detector operates by detecting X-ray automatically. 2 Connect one end of the LAN cable to one of the LAN ports of SCU, and the other to the LAN Card Connector of workstation assigned for data transfer. 3 Stand the antenna of SCU upright. 4 To transmit image data using a Tether Interface, connect the one end of the Tether Interface cable to the Port 4 or Port 5 of SCU and the other to the detector. If you use the wireless communication method, a tether interface cable is not needed as the image is transmitted wirelessly. 5 To supply power, connect the AC power cable to the AC power input port of SCU. Rev.1.0 Page 68 of 151 VW40-153-006 VIVIX SCU mini (FXRS-04A) VIVIX-S 1717N User Manual 1 If you use the DR Trigger mode, connect the one end of generator interface cable to the EXT_INF port of SCU mini, and the other to the X-ray generator. If you use the AED mode, a generator interface cable is not needed as the detector operates by detecting X-ray automatically. 1 Connect one end of the LAN cable to one of the LAN ports of SCU mini, and the other to the LAN Card Connector of workstation assigned for data transfer. Stand the antenna of SCU mini upright. 2 To transmit image data using a tether interface, connect the one end of the tether interface cable to the port of VIVIX SCU mini and the other to the detector. If you use the wireless communication method, a tether interface cable is not needed as the image is transmitted wirelessly. 3 To supply power, connect the DC power cable to the DC power input port of SCU mini. Rev.1.0 Page 69 of 151 VW40-153-006 4.2.2 Booting up SCU VIVIX-S 1717N User Manual 1 Turn on the power switch at the front side of SCU. 2 Check if the power switch of SCU lights up green. 3 Check if the status indicator is blinking in green after the power switch of SCU is permitted. 4 Check if the status indicator of SCU is blinking in green and turns to light up in the same color. When the power switch lights up green, it means that the power is applied normally. When the status indicator is blinking in green, the SCU is booting. If the status indicator lights up green, it indicates that the SCU is being operated normally after booting up. 4.2.3 Booting up the Detector The procedures in this chapter are explained according to the default setting status of a detector (factory reset) and the use of wireless connection. Refer to <7.5 Product Initialization> for the detailed information about the default setting status of a detector. 1 Attach a charged battery pack to the detector. 2 Press the power button of the detector for 1 second until the power LED is turned on. 3 When the power LED is on, check if it is lit green. 4 Check if the active LED is lit orange on the detector. Rev.1.0 If the power LED lights up green, the DC power is permitted normally. If the active LED lights up orange, the detector is compeleted to boot up normally. Page 70 of 151 VW40-153-006
1 2 | User Manual 2 | Users Manual | 3.81 MiB | April 30 2015 |
4.2.4 Checking Status LED of Detector VIVIX-S 1717N User Manual Power LED The power LED indicates the power status information which is permitted to the detector in green. The power LED lights up when the power is permitted normally. If the detector is connected with a tether interface, the power LED lights up when power is permitted to SCU because the detector is supplied power from SCU. Active LED The active LED indicates status information about the possibility that the detector can be used normally or not in orange. The active LED is blinking when the detector is completed to boot up normally. The Power LED is blinking when the detector turns to sleep mode. The active LED is blinking when the wireless communication is being initialized. Data LED The data LED indicates status information of data processing in blue. The data LED lights up when the detector is available to make data communication. The data LED is blinking while the detector transmits or saves data. Detector AP LED The AP LED lights up in blue when the detector AP is on. The AP LED is blinking in blue when the detector switches the AP status. The AP LED is blinking in orange while the detector is synchronizing the wireless settings. The communication status of detector is indicated when the detector AP is off. Wirelss communication: Green LED at the 3rd level or higher / Orange LED under 2nd level. Wired communication: Green LED in case of 1Gbps / Orange LED in case of 100Mbps connection. Summary List of Detector Status LED Information Power LED Status LED Data LED In process of booting after the power permission Booting completed (Abnormal) Booting completed (Normal) Ready for communication Sleep Mode In process of wireless initialization Data Communication (Send or Store) Blink ON ON ON ON ON ON OFF
-
ON ON Blink Blink ON Power OFF OFF OFF OFF
-
OFF OFF OFF OFF ON Blink Rev.1.0 Page 71 of 151 VW40-153-006 VIVIX-S 1717N User Manual Summary list of the Detector AP LED Information Detector AP LED Detector AP OFF (Communication status: Good) Wireelss communication: 3rd level or higher Wired communication: 1000Mbps Detector AP OFF (Communication status: Normal) Wireelss communication: Under 2nd level Wired communication: 100Mbps Detector AP ON Switching the status of detector AP The wireless setting is being synchronized ON ON ON Blink Blink Power OFF OFF If the LED blinks abnormally, refer to <8 Troubleshooting> to check if communication or system error is occurred. Rev.1.0 Page 72 of 151 VW40-153-006 4.3 Software Installation VIVIX-S 1717N User Manual This section gives information about how to install the software on the workstation (PC) and how to configure the environment for software operation and communication. Check suitability of acquiring, processing and adjusting of images by referring to the recommended workstation specifications before the software installation. 4.3.1 Software Classification Vieworks provides clients who purchase our detector system with software as below. You can choose and use one of our softwares below. Software Description A program for acquiring and adjusting images developed by Vieworks. VXvue Used for VIVIX-S detectors only. Unnecessary to develop a separate viewer program. VIVIX Setup A program for setting and managing the detector and SCU. VXvue (Viewer) Software for acquiring, adjusting and managing the image. XIPL Image processing program Document VXvue Operation Manual XIPL User Manual VIVIX SDK Software development kit for VIVIX-S detector only, provided by Vieworks. You can develop your own software dedicated to VIVIX-S by using this kit. SDK Package Development package VIVIX Setup A program for acquiring, adjusting and managing the image. Document VIVIX SDK Developer Manual 4.3.2 Software Installation For a client who uses VXvue, install the VXvue program after reading VXvue Operation Manual carefully. For a client who uses VIVIX SDK, install the VIVIX Setup program after reading VIVIX SDK Developer Manual. Be sure to install the software first with reading this manual before configuring Windows environment. Apart from the detector and SCU, the software can be installed separately. Rev.1.0 Page 73 of 151 VW40-153-006 VIVIX-S 1717N User Manual 4.4 Windows Environment Setting This section gives information about configuring Windows to communicate with the detector and SCU after installing the VIVIX Setup program or Viewer. The contents in this chapter are made on the basis of Windows 7. Configuration environment can be different depending on network adaptor manufacturer or models. 4.4.1 Network Configuration Communication disruption between the detector (or SCU) and workstation occurs unless the network adaptor is proper is set properly, it may cause serious repercussion to the product and image quality. Selecting Network Adaptor 1 Click Start Control Panel Network and Internet Network and Sharing Center Change Adapter Setting. 2 Choose the networks adaptor for communicating with the detector and SCU, and then rename it. It is recommended to change the name of network adaptor to distinguish it from other connection names. Even though the name is changed, it will not affect to the operation and communication performance of the equipment. 3 Click the chosen network adaptor with the right mouse button and click Properties to display the Properties window. Rev.1.0 Page 74 of 151 VW40-153-006 Setting Network Adaptor 1 Click Configure button to open the following dialog box, and then go to the Advanced tab. 2 Set Jumbo Packet to the maximum value. (Recommended value: 9014 Bytes) VIVIX-S 1717N User Manual 3 Choose Performance Options in the list of Settings and click Properties button on the right. 4 Choose Flow Control in the list of Settings and select Rx & Tx Enabled on the Value list as shown below. Rev.1.0 Page 75 of 151 VW40-153-006 VIVIX-S 1717N User Manual 5 Choose Interrupt Moderation Rate in the list of Settings and select Extreme on the Value list as shown below. 6 Choose Receive Buffers and set it to the maximum value. 7 Click OK button. Deactivate Power-Saving Mode on Network Adaptor 1 Click the Power Management tab and uncheck Allow the computer to turn off this device to save power. 2 Click OK button. Rev.1.0 Viewer may not work normally if the power save mode is activated. Deactivate the power save mode of all the installed network adaptors. Page 76 of 151 VW40-153-006 Protocol Selection and IP Address Setting 1 Choose Internet Protocol Version 4 (TCP/IPv4).and click Properties button. 2 Input the IP address and subnet mask as shown below, and then click OK button. VIVIX-S 1717N User Manual ViVIX Device Driver is the image filter driver for acquiring images from a detector. It is recommended to uncheck the other items on the list except for ViVIX Device Driver and Internet Protocol Version 4(TCP/IPv4), since they are not related with the detector communication. Summary of Network Configuration Item Jumbo Packet Flow Control Interrupt Moderation Rate Receive Buffers Value Maximum or 9014 Bytes Rx & Tx Enabled Extreme Maximum Allow the computer to turn off this device to save power Unchecked IP Address Subnet Mask 169.254.0.(50 ~ 254) 255.255.0.0 It is recommended to set the IP address and subnet mask within the range presented in this document. If you use IP address and subnet mask out of the suggested range, it could be difficult to identify and resolve the cause of communication disorder. Rev.1.0 Page 77 of 151 VW40-153-006 4.4.2 Disabling Sleep Mode of Monitor VIVIX-S 1717N User Manual If you use the sleep mode, viewer may not work normally. 1 Click Start Control Panel Power Options and then move to the Choose when to turn off the display tab. 2 Set Put the computer to sleep to Never to disable the sleep mode. 3 Click Save changes button. Rev.1.0 Page 78 of 151 VW40-153-006 VIVIX-S 1717N User Manual This section gives information about the product setting with using the Setup program. 5. Setting Start Setting SCU Setting Detector Setting Changing the Wireless Setting Rev.1.0 Page 79 of 151 VW40-153-006 5.1 Start Setting 5.1.1 Setup Program VIVIX-S 1717N User Manual The VIVIX Setup program provides functions for setting and managing the internal data to make VIVIX-S 1717N wireless detector and SCU work normally. In addition, The VIVIX Setup program has diagnostic function for checking performance and abnormality of the devices as well as the image calibration function for improving the image quality. 5.1.2 Checking Devices Check information of the detector and SCU displayed on the Discovery list.
[TBD] Screen Shot Click Refresh Device List button to make the VIVIX Setup program search all detectors and SCU connected with the same network again. If devices are not displayed, check the power connection of the detector and click Refresh Device List button again. List Information List SCU Use Description Displays discovered list of SCU devices. Double-click the option to decide wether to use SCU or not. V is displayed when it is able to be used. Discovery Displays whether SCU is found out or not. Detectors Displays discovered list of detectors. (Max. 4) ID ID of detector(sequence to distinguish registered detector) Line Trigger Selects a pin group when using Line Trigger. Discovery Displays whether the detector is discovered or not. Common Model No. Model name of SCU or detector Serial No. Serial number of SCU or detector IP Address IP Address of SCU or detector MAC Address MAC Address of SCU or detector Rev.1.0 Page 80 of 151 VW40-153-006 VIVIX-S 1717N User Manual The default IP address of SCU is 169.254.2.100. The default IP address of detector is 169.254.1.10. You can change the IP Address of detector or SCU. Refer to Change Configuration on the next page. MAC address is a unique indentifier of the network device. Do not change it randomly. To change order of registered detectors ID, select an item and click /buttons. If detectors which have same IP address are connected at the same time, the address is changed automatically to prevent address collision. Color and Font Information Description Green background Registered status. Available to get into the device. White background Non-registred status. Unavailable to get into the device. Bold font Connected status. The device is connected. Gray background / font Disconnected status. The device has been connected, but is disconnected now. The device is changed to the registered or non-registered status by double-clicking the device name or clicking Select or Release button. Change Configuration Select the SCU or detector name and click the right mouse button to change its setting. Menu SCU Description
-
Configuration Changes the setting information of SCU. Change IP Changes IP address of SCU. Detector
-
Release Change IP Releases the detector to non-registered status. Changes IP address of the detector. Rev.1.0 Page 81 of 151 VW40-153-006 5.1.3 Getting into the Devices VIVIX-S 1717N User Manual Click Next button to enter the registered SCU and detector. You can use SCU and the detector normally when the status of SCU is Connected and the Status of detector is Initialization OK. Button Button SCU
[TBD] Screen Shot Description Configuration Checks and sets information of SCU setting. Diagnosis Checks information of wireless AP on SCU and performs the self-diagnosis. Detector Configuration Checks and changes the information of detector settings. Calibration Checks and calibrates the detector calibration data. Image Checks and diagnoses the detector and acquired image. Diagnosis Checks the information of detector and tests the wireless transmission function as well as performs the self-diagnosis. Rev.1.0 Page 82 of 151 VW40-153-006 5.2 SCU Setting 5.2.1 SCU Configuration VIVIX-S 1717N User Manual System Checks and sets system information of SCU. Item Model No Serial No Package Description SCU model name SCU serial numbers Version information of SCU firmware package Network Checks and sets network information of SCU. Item IP Address Net Mask Gateway Description IP address of SCU. Subnet Mask of SCU. Gateway of SCU. Rev.1.0 Page 83 of 151 VW40-153-006 AP VIVIX-S 1717N User Manual Checks and sets AP (Access Point) information of SCU. Item Description AP On / Off Selects whether to use SCU AP (Access Point) mode or not. On Off Turns on SCU AP Turns off SCU AP Frequency Frequency channel of wireless network. 2.4 5 Uses 2.4 Frequency. (Max. 13 channels) Uses 5 Frequency. (Max. 8 channels) Country Band 20 40 Country code of using wireless network. (KR, US, EU, JP, CN) Wireless network bandwidth. Default frequency band. Expands bandwidth through channel bonding. Channel Wireless communication channel Unique ID for wireless communication Unique key for wireless communication (Applied to the password only.) 13 channels can be used in 2.4 Frequency. 8 channels can be used in 5 Frequency The number of serviceable channels is different according to the configured country. Channel bonding is used for enhancing transmission speed. However, the speed may be slowed down due to the interference of surrounding channels, even if the channels have been bonded. Channel items (+/-) will be activated in case of using 40 frequency bandwidth. You can set whether to bond channels with the above or below one. SSID and Key values of the detector communicated with SCU should be set as the same. Set SSID and Key values not to be duplicated with those of the peripheral system. The maximum value of SSID is 20 letters and the Key is 63 letters. (Minimum Key value:
8 letters). The input letters are limited to capital / small alphabets, -, _ among special letters and numeric characters. Wireless network setting should be done by an engineer who understands the wireless communication and its related technique. Unless the network is set properly, a communication error would occur or the image quality would be affected. SSID Key Rev.1.0 Page 84 of 151 VW40-153-006 Trigger VIVIX-S 1717N User Manual Configures trigger information for integration between SCU and X-ray generator. Item Method Description Trigger mode Packet Line Software Trigger mode Hardware Trigger mode Polarity Polarity of trigger signal AUTO (Default) Recognizes polarity automatically and handles it. (Default value) HIGH LOW Handles polarity of Active High Handles polarity of Active Low Configuration value of trigger is applied only when Exposure mode is set DR Trigger. Configuration value of trigger is not applied when using AED mode. The setting of Trigger should be done by an engineer who understands about the x-ray generator device well. Unless the device and detector are set correctly, an integration error of x-ray generator would occur or the system operation would be affected. Command Buttons Item Set Config Description Updates by transmitting current setting values to SCU. Factory Reset Resets SCU to factory default settings. Log Close Checks the logs of SCU. Closes the window of SCU Configuration. If Set Config is not performed, the changed setting value is not transmitted to SCU. Rev.1.0 Page 85 of 151 VW40-153-006 5.2.2 SCU Diagnosis Self Diagnosis You can perform self-diagnosis to check operational status of the parts in SCU. VIVIX-S 1717N User Manual Refer to <7.2 Product Inspection> for the detailed information on how to perform the self-diagnosis and about the follow-up measures. Rev.1.0 Page 86 of 151 VW40-153-006 5.3 Detector Setting 5.3.1 Detector Configuration VIVIX-S 1717N User Manual
[TBD] Screen Shot System Checks and sets system information of the detector. Item Model No Serial No Package Network Description Detector model name Detector serial numbers Version information of the detector firmware package Checks and sets network information of the detector. Item IP Address Net Mask Gateway WNetwork Description IP address of the detector Subnet Mask of the detector Gateway of the detector Sets AP (Access Point) information of wireless communication from the detector. Item SSID Key Description Configures wireless network ID AP from the detector. Configures wireless network key value of AP from the detector. Wireless Only Configures the wireless communication method of the detector. On Off The detector is operated in a wired way when a tether interface cable is connected. The detector is operated in a wireless way when a tether interface cable is not connected. Rev.1.0 Page 87 of 151 VW40-153-006 AP VIVIX-S 1717N User Manual Checks and sets AP (Access Point) of detector information. Item AP On / Off Frequency Description Executes or disables the detector AP (Access Point) function. Frequency channel of wireless network 2.4 5 Uses 2.4 Frequency. (Up to 13 channels) Uses 5 Frequency. (Up to 8 channels) Country Band 20 40 Country code of wireless network (KR, US, EU, JP, CN) Wireless network bandwidth Basic Frequency Band Expands bandwidth through channel bonding. Channel Wireless network channel SSID Key Wireless network ID Wireless network key value (Applied to the password only.) 13 channels can be used in 2.4 Frequency. 8 channels can be used in 5 Frequency The number of serviceable channels is different according to the configured country. Channel bonding is used for enhancing transmission speed. However, the speed may be slowed down due to the interference of surrounding channels, even if the channels have been bonded. Channel items (+/-) will be activated in case of using 40 frequency bandwidth. You can set whether to bond channels with the above or below one. SSID and Key values of the detector for communicating with SCU wirelessly (WNetwork) should be set as the same. Set SSID and Key values not to be duplicated with those of the peripheral system. The maximum value of SSID is 20 letters and the Key is 63 letters. (Minimum Key value:
8 letters). The input letters are limited to capital / small alphabets, -, _ among special letters and numeric characters. Wireless network setting should be done by an engineer who understands the wireless communication and its related technique. Unless the network is set properly, a communication error would occur or the image quality would be affected. Rev.1.0 Page 88 of 151 VW40-153-006 Image VIVIX-S 1717N User Manual Checks and sets the time limit of image transmission as well as decides whether to use the Preview item. Item Description Time (sec.) The limited time of completing image transmission. Preview (Enable / Disable) Sets whether to use the wireless communication way for sending preview images. After starting image transmission, the detector ignores the information of image re-
transmission request if the following conditions are fulfilled. If the time limit of image transmission does not exceed. If the image is not transmitted completely. Power Mode Checks and sets the management information about the power of detector. Item Sleep Description Decides whether to use the sleep mode function of the detector. (On / Off) If the detector is not used for the specific setting time, it is turned to the sleep Sleep after (min.) mode. This mode activates only when the sleep mode is set. (10 / 15 / 20 / 25 /
30 min.) Shut Down Sets whether to use the shut down function in the detector. (On / Off) Shut Down after (min.) The power of detector is off if it is not used within the setting time. This menu is activated while the Shut Down function is used. (30 / 60 / 90 / 120 min.) Power Control Sets standards of power supply to the detector. by Detector by SCU The detector is operated by power from SCU and battery. If the power from SCU and battery is blocked, the detector is turned off. The detector is operated by power from SCU with connecting a tether cable. If the power from SCU is blocked, the detector is turned off. You can prevent unnecessary battery consumption by using the Sleep function. When SCU supplies power to the detector with connecting a tether interface cable, the Shutdown function cannot be operated. If Power Off is set to by Detector and the tether interface cable is disconnected, you can keep using the detector by the power of battery. In this case, you can turn off the detector by pressing the power button for 3 seconds. If a tether interface cable is disconnected while Power Off is set to by SCU, the detector is turned off since the battery cannot supply power to the detector. Wireless network setting should be done by an engineer who understands the wireless communication and its related technique. Unless the network is set properly, a communication error would occur or the image quality would be affected. Rev.1.0 Page 89 of 151 VW40-153-006 VIVIX-S 1717N User Manual 5.3.2 Detector Power Save Function The consumption of a battery pack can be reduced by using the power save function. Mode Mode Normal Sleep The power save function is operated only when the battery supplies power to the detector. In other words, the power save function cannot be operated if a tether interface cable supplies power to the detector. Meaning The detector can be operated and take an image at any time. The detector cannot be operated. User can take an image by disabling the Sleep mode. Shut Down The detector has been turned off. User can take an image after the detector is rebooted. Setting Items of Power Save Function Mode Normal Sleep Sleep after (min.) Meaning
-
Selects the function On (use) or Off (not use). Sleep mode is activated if the detector is used during the setting time. (10 / 15 /
20 / 25 / 30 min.) Shut Down Selects the function On (use) or Off (not use). Shutdown after (min.) The detector is turned off if it is not used during the setting time. This menu is activated while the Shut Down function is used. (30 / 60 / 90 / 120 min.) Entry Condition of Power Save Mode Mode Normal Sleep Meaning
-
The detector turns to sleep mode if not used for the setting time (Sleep after). The detector is turned off if not used for the setting time (Shutdown after) under the Shut Down sleep mode. However, if the detector is not used for the setting time (Shutdown after) under the sleep off state, the detector is turned off. Checks Power Save Mode Mode Normal Meaning All LED lamps are turned on. Power LED (Green) is blinking. Sleep VXvue (Vieworks Viewer) indicates the state of sleep mode. VIVIX SDK indicates the state of sleep mode. Shut Down All LED lamps are turned off. Rev.1.0 Page 90 of 151 VW40-153-006 VIVIX-S 1717N User Manual Disabling Power Save Function Mode Normal Sleep Meaning
-
1 Turns off sleep mode from VXvue (Vieworks Viewer). 2 Calls the function from VIVIX SDK to turn off sleep mode. Shut Down Reboots the detector by pressing a power button on the detector. Other Information Mode Default value Turnaround time Power consumption Normal
-
-
24V, 300mA (Standby) 24 V, 600mA (While taking images) Sleep OFF / 10min. Approx. 10 sec. 24V, Max. 150mA Shut Down OFF / 30min. Approx. 15 sec.
-
Rev.1.0 Page 91 of 151 VW40-153-006 VIVIX-S 1717N User Manual 5.4 Changing the Wireless Setting 5.4.1 Switching to the Detector AP Mode You can change the detector mode as AP by the two ways as follows. Convert to the Detector AP mode by using the Detector AP button Press the AP button on the detector for 5 seconds to set the Detector AP mode. The LED of detector AP blinks in a blue color while the mode is being switched, and turns on blue after the mode is compeleted to be converted. This method can be used only when the detector is under the wireless communication status without connecting a tether interface cable. Convert to the Detector AP mode from VIVIX Setup Choose the AP option as On or Off from the Detector Configuration dialog in VIVIX Setup program. 5.4.2 Synchronizing the Wireless Setting Synchronize the wireless setting with a tether interface cable as follows. 1 Connect the detector and SCU with a tether interface cable. 2 Press the detector AP button for 5 seconds after the detector is turned on. 3 4 The LED of detector AP blinks while processing synchronization. The sync information is saved automatically after it is transmitted to the detector where SSID and KEY of SCU are connected. 5 The detector is switched to the wireless communication mode. Rev.1.0 Page 92 of 151 VW40-153-006 VIVIX-S 1717N User Manual 6. Calibration This chapter gives information about the calibration methods after installing a detector. Calibration Dialogue Detector Configuration Calibration Guide Calibrating by Loading the Calibration Data Direct Calibration Rev.1.0 Page 93 of 151 VW40-153-006 6.1 Calibration Dialogue VIVIX-S 1717N User Manual Use the following menus to configure the system and process calibrations. Menu Description System Configuration Configures the exposure mode, exposure-related time and Gain type. Offset Calibration Processes Offset calibration. Defect Calibration Processes calibration for defect data of the detector. Gain Calibration Processes calibration for image sensitivity. Detector Configuration Configures the detector information related to calibration and image. The menu status is displayed as Done when each calibration is finished. You cannot operate the detector if the status is not displayed as Done. 6.1.1 System Configuration Dialogue Configure the generator interface information from System Configuration in Step. Exposure Mode The VIVIX-S 1717N detector provides two types of mode for taking images as follows. Mode AED Description Detects X-ray automatically without connecting the detector to X-ray generator. The detector acquires images after the automatic detection. Detects the X-ray exposure signal of X-ray generator in advance by connecting the DR Trigger detector to X-ray generator with a generator interface cable. The detector acquires images after preparing exposure with the exposure signal. Rev.1.0 Page 94 of 151 VW40-153-006 VIVIX-S 1717N User Manual Exposure Timing To take images exactly, set the timing information for exposure. The information can be different depening on the characteristics of the X-ray generator. Exposure Timing Diagram Exposure Timing Items Item Default Description Exposure section 500 Time to acquire X-ray by the detector. Pre Exposure section 0 Standby time after the detector sent EXP_OK signal to the generator. EXP OK Delay section 1 The delayed time to receive EXP_OK signal from the detector after the generator sent EXP_REQ signal to the detector. The required time to check signals from the generator for preventing Debounce_DR 3 image acquisition from external noise. It can be used when DR Trigger mode is selected only. The required time to check sensor signal from X-ray to prevent image Debounce_AED 3 acquisition from external noise. It can be used when AED mode is selected only. Rev.1.0 Exposure section should be set longer than the maximum exposure time to prevent X-ray loss. Page 95 of 151 VW40-153-006 VIVIX-S 1717N User Manual When Exposure section is changed, make sure to create new calibration data by processing Offset calibration and Gain calibration to get optimized images. Pre Exposure section can be used when the time delays until the generator receives EXP-
OK signal from the detector and generates X-ray. Although Pre Exposure section is set as 0 normally, it is recommended to measure and set the actual delay time of X-ray generation to achieve the best performance of the detector. The detector sends EXP_OK signal to the generator, then acquires X-ray after the setting time in Pre Exposure section. EXP OK Delay section is the delayed time between the detection time of exposure request signal (EXP_REQ) from the X-ray generator and the time before sending exposure respond signal (EXP_OK) to the X-ray generator. Some X-ray generators need time to prepare detecting EXP_OK signal after sending EXP_REQ signal. This time is determined according to the specifications of X-ray generator. Debounce_DR is used for removing the trigger signal due to external noise when the exposure mode is set as DR Trigger. If the value is set to less than 3, the detector may acquire undesirable images. Debounce_AED is used for removing trigger signals due to external noise when the exposure mode is set as AED. If the Debounce_AED value is set longer than the X-ray exposure time, the detector cannot acquire images. If unwanted images are acquired without X-ray exposure while the equipment is operated, set Debounce_AED with 1 increments. However, we recommend you not to set the value more than 10. Digital Offset After Offset Calibration, you can configure base level of pixel on Digital Offset item, in order to minimize loss of pixel value if it is below base level point. Gain Type You can select the Gain Type to adjust sensitivity of the detector for acquiring X-ray images with desired brightness according to the specifications of X-ray generator or the object type. The following table describes the sensitivity ratio of each Gain Type of the VIVIX-S 1717N detector. Gain Type 0 1717NA(W) (CsI) 0.99 1717NB(W) (Gadox) 0.87 1 1.16 1.0 2 1.39 1.18 3 1.73 1.44 4 2.3 2.17 5 3.47 3.25 Rev.1.0 Page 96 of 151 VW40-153-006 VIVIX-S 1717N User Manual To acquire the optimized images, carry out the Offset calibration and Gain calibration again after changing Gain Type. 6.1.2 Offset Calibration Dialogue Vieworks provides the Defect Map data stored in the detector. However, we recommend you to carry out the Offset calibration and generate the Offset data by yourself as the detector condition can be different by the operating method or use environment. Offset Calibration Item Description Current value Shows value when performing the manual Offset calibration. Stage Selects the performance frequency of manual Offset calibration and shows each calibration stage. Run Offset Calibration Performs the manual Offset calibration. Download Offset Downloads the Offset data stored in the detector. Offset path Shows the path of the applied Offset data. Rev.1.0 Page 97 of 151 VW40-153-006 6.1.3 Defect Calibration Dialogue VIVIX-S 1717N User Manual Vieworks provides the Defect Map data stored in the detector. However, you should download the data as the calibration cannot be performed in the detector automatically. Defect Map Item Description Load Defect Map Loads the Defect Map calibration data located in the defect map path. Download Defect Map Downloads the Defect Map calibration data stored in the detector. Manual Defect Correction Calibrates the defect manually. Defect Map Path Shows the path of applied Defect Map data. This Defect Map data has been generated through stringent test in the production stages of detector. However, new defect may be newly formed while using the detector. In this case, make sure to calibrate defects in person and generate a new defect map. Rev.1.0 Page 98 of 151 VW40-153-006 6.1.4 Gain Calibration Dialogue VIVIX-S 1717N User Manual Vieworks provides the Gain data stored in the detector. However, you should download the data as the calibration cannot be performed in the detector automatically. Gain Calibration Item Description
[TBD] Screen Shot Target Value Shows the target value of Gain calibration. (Recommended : 8000 or higher) Current Value Shows value after the exposure when processing the manual Gain calibration. Stage Get Cancel Selects the number of manual Gain calibration and shows each calibration stage. Starts the manual Gain calibration. Cancels the manual Gain calibration. Load Gain Loads the Gain calibration data located in the Gain path. Upload Gain Uploads the Gain calibration data to the detector for using portable mode. Download Gain Downloads the Gain calibration data stored in the detector. Gain Path Shows the path of applied Gain data. This Gain data is provided in case the Gain calibration cannot be performed. You should do the Gain calibration in person as the detector condition can be different by the operating method or use environment. Rev.1.0 Page 99 of 151 VW40-153-006 6.2 Detector Configuration VIVIX-S 1717N User Manual From the Detector Configuration dialog, you can configure the detector and check the images before or after doing calibration. Function List
[TBD] Screen Shot Item Description Detector Direction Compensation Sets the displayed direction of image. Effective Area Sets effective area of an image. Auto Offset Refresh Setting Sets conditions of automatic Offset Refresh. Time Interval (min.) Checks cycle of temperature change Temperature Interval () Difference of over-temperature. Number of shot Number of Offset Refresh. Edge Masking (On / Off) Sets outside of the effective area to specific values. OSF Chooses whether to use OSF or not. Button Item Pan Zoom W/L Fit E.A. ROI Description Moves an image to the desired location. Extends or constract an image. Adjusts window level of an image. Displays an image by adjusting it to the screen. Sets the effective area of an image with a mouse. Sets the image area of interest. Effective Area On / Off Displays effective area of an image only. You can only change the displayed direction of an image from Detector Direction Compensation. The direction of an original image cannot be changed. Effective Area can be changed within the effective range which has been configured at the time of the first shipment of detector. Once Use offset refresh is used, the offset refresh is processed automatically as follows. Checks temperature difference of the detector between current temperature and the previous one at the time of offset refresh in every setting time from Time Interval. If the temperature difference is more than the one set in Temperature Interval, the offset refresh is carried out a number of times set in Number of shot. Rev.1.0 Page 100 of 151 VW40-153-006 VIVIX-S 1717N User Manual If you use VXvue, a pop-up message will be displayed before the offset refresh. Auto offset refresh will be performed by clicking OK button. OSF is the auxillary function for stabilizing pixel value of an image to the default value rapidly. The pixel value can be displayed equally by using OSF under the environment where the pixel value of X-ray image is required to display. Whether to use OSF or not does not affect the X-ray image quality. Rev.1.0 Page 101 of 151 VW40-153-006 6.3 Calibration Guide VIVIX-S 1717N User Manual The different installation environment of each detector and unique features of the X-ray generator device can affect the acquired images. Therefore, the certified engineer from Vieworks should do the detector calibration after installing it. Otherwise, the image quality can be affected seriously. Vieworks provides two types of calibration for performing calibration. Performing calibration by loading the calibration data provided by Vieworks. The service engineer proceeds calibration and generate calibration data. We strongly recommend the service engineer to carry out the calibration in person since the detector condition and image quality can be different by the operation method or use environment. Rev.1.0 Page 102 of 151 VW40-153-006 VIVIX-S 1717N User Manual 6.4 Calibrating by Loading the Calibration Data Vieworks provides the calibration data stored in the detector. Although the Offset calibration is performed automatically, you need to download both Defect and Gain calibration data since their calibration cannot be performed in the detector automatically. 6.4.1 Preparing Calibration Data File Offset Gain Description Detector Offset data Calibration data for image sensitivity Defect Map Defect calibration map data It is not necessary to download the Offset calibration data since the data is used in the detector. 6.4.2 Loading Defect Calibration Data 1 Select Defect Calibration from the Step list. 2 Click Download Defect Map button to assign the path of local HDD, and download the Defect Map calibration data. 3 Click Load Defect Map button to load the calibration data. Rev.1.0 The calibration menu status is displayed as Done when the Defect calibration data is loaded completely. Page 103 of 151 VW40-153-006 VIVIX-S 1717N User Manual Be sure to select the Defect Map data file provided with a detector. If the file has a wrong serial number or you select a wrong file, an error message will be displayed. Vieworks provides the Defect Map data stored in the detector. However, you should download the data as the calibration cannot be performed in the detector automatically. This Defect Map data has been generated through stringent test in the production stages of detector. However, new defect may be newly formed while using the detector. In this case, make sure to calibrate defects in person and generate a new defect map. 6.4.3 Loading Gain Calibration Data
[TBD] Screen Shot 1 Select Gain Calibration from the Step list. 2 Click Download Gain button to assign the path of local HDD. 3 Download the Gain calibration data by clicking Load Gain button. The calibration menu status is displayed as Done when the Gain calibration data is completed to be loaded. Be sure to select the Gain calibration data file provided with a detector. If the file has a wrong serial number or you select a wrong file, an error message will be displayed. Vieworks provides the Gain calibration data stored in the detector. However, you should download the data as the calibration cannot be performed in the detector automatically. This data is provided in case the Gain calibration cannot be performed. You should do the Gain calibration in person as the detector condition can be different by the operating method or use environment. Rev.1.0 Page 104 of 151 VW40-153-006 6.5 Direct Calibration 6.5.1 Prepration VIVIX-S 1717N User Manual Precheck the state of X-ray generator and console. Precheck the state of X-ray tube. It is recommended you to check if X-ray dose value of the generator is exact by using the device like a dose meter. Make sure to preheat the detector for 30 minutes before starting calibration. The result of measurement can be incorrect if the detector is not preheated sufficiently. 6.5.2 Offset Calibration 1 Set the number of Stage as 5 in the Offset Calibration area. 2 Click Run Offset Calibration button and progress the Offset calibration. Rev.1.0 Page 105 of 151 VW40-153-006 6.5.3 Gain Calibration VIVIX-S 1717N User Manual 1 Put a collimator on center of the detector, and open the collimator completely. 2 Adjust SID as 130 ~ 150 to make X-ray exposure range include the detector. 3 Remove any objects or foreign materials between the tube and the detector. 4 Choose Gain Calibration -Normal. 5 Set the tube voltage of X-ray generator as 70 ~ 80. 6 While acquiring images, adjust the X-ray dose condition ( or ) until Current Value of the Gain Calibration area is formed between 8000 and 10000. 7 Set the exposure number of Stage as 10 when the adjustment of exposure condition is completed. 8 Click Get button, and keep making an X-ray exposure at 15 sec intervals. 9 Save the Gain Calibration data as a file. Make sure to progress Gain Calibration again if the cases below are applicable. When the settings of Exposure Section or Gain Type is changed from the VIVIX Setup program. When the exposure devices like X-ray generator are repaired. When the exposure environment is changed. When the service engineer decides that it is need to progress Gain Calibration. Rev.1.0 Page 106 of 151 VW40-153-006 6.5.4 Auto Defect Correction VIVIX-S 1717N User Manual While operating the detector, defect pixels may appear on the image. In this case, use the defect auto correction to calibrate the defect pixels. Be sure to check the followings before acquiring the FLAT image. Preheat the detector for 30 minutes or more. The recommend SID is 150 (distance between X-ray tube and detector) Open the collimator of X-ray tube completely. Align the center of the detector with the center of collimator. Keep everything away from the detector surface. Adjust the x-ray dose to make the pixel value from 900 ~ 1100. Check if the calibration data (Offset, Defect Map, Gain) is registered normally. 1 Make an exposure of FLAT images from the Image dialog box. 2 Click Save Image button to save images to the user-defined folder. (saved as a raw file.)
[TBD] Screen Shot 3 Close the Image dialog box, and open the Calibration dialog box. 4 Choose Defect Calibration as follows and click Manual Defect Correction button. 5 Move to the folder where the raw file is saved and select the file.
[TBD] Screen Shot Rev.1.0 Page 107 of 151 VW40-153-006 VIVIX-S 1717N User Manual 6 The Manual Defect Detection screen will be displayed. 7 Click Show and Apply buttons on the top left and then click Auto Defect Finder button. 8 Input 15% for Threshold, and 100 for Offset at the bottom of the Pixel List screen. 9 Click Search button at the bottom of the screen. The coordinates of defect pixels and Gray level values are displayed on Pixel list. 10 While pressing the Ctrl or Shift key, select the coordinate of defect pixels to be added to Defect Map. 11 Click Add button to add the selected items to Pixel List in Manual Defecct Detection. 12 Check if the selected defect pixels are added to the pixel list on the left. Rev.1.0 Page 108 of 151 VW40-153-006 VIVIX-S 1717N User Manual 13 Click Save and Close button at the left bottom. 14 Save the newly generated Defect Map data to the path where the Calibration data has been stored. It is recommended to save the newly generated Defect Map data with a different name to preserve the past Defect Map data. Rev.1.0 Page 109 of 151 VW40-153-006 6.5.5 Manual Defect Correction VIVIX-S 1717N User Manual Execute Manual Defect Detection when the defect pixels are visible to the naked eye even the automatic defect correction (step 1~14) is processed. Manual Defect Detection is divided into the pixel type and line type. Manual Defect Correction in Pixel Type 1 Make sure to carry out the automatic defect correction from 1 to 14 steps first. 2 Click Show and Apply buttons on the left top of Manual Defect Detection. 3 Press and hold the right mouse button and move it to left/right/top/ bottom in the FLAT image to adjust the brightness until you can verify the image with the naked eyes. 4 Click Add Pixel Button. 5 Use the Zoom or Pan function properly to find and click the location of defect pixel. Red point will be displayed and coordinate of the pixel will be added on the Detect Map List on the left upper. 6 Click Save and Close button to save the Defect Map data with a new name. If a selected pixel has a difference in the brightness or gray level value (more than 15%) compared to the adjacent pixels, the pixel may be regarded as a defect pixel. A window located on the left top will magnify and display the pixel where the mouse pointer is located. The coordinate and Gray level value of the pixel will be displayed under the window. Rev.1.0 Page 110 of 151 VW40-153-006 VIVIX-S 1717N User Manual Manual Defect Correction in Line Type 1 Make sure to carry out the automatic defect correction from 1 to 12 steps first. 2 Click Show and Apply buttons on the left top of Manual Defect Detection. 3 Press and hold the right mouse button and move it to left/right/top/bottom in the FLAT image to adjust the brightness until you can verify the image with the naked eyes. 4 Find and move to the start point of defect lines (line type) on the image. 5 Click Add V-Line or Add H-Line button. 6 Press and hold the left mouse button on the first defect pixel, move the mouse to the opposite direction and release the mouse button on the last pixel of Line Defect pixel. 7 A red line will be displayed on the image and check if pixels on the line are added to the Defect Pixel list. 8 Click Save and Close button to save the newly generated Defect Map data with a new name. If a selected pixel has a difference in the brightness or gray level value (more than 15%) compared to the adjacent pixels, the pixel may be regarded as a defect pixel. A window located on the left top will magnify and display the pixel where the mouse pointer is located. The coordinate and Gray level value of the pixel will be displayed under the window. If there are pixels existed without defect correction even though you conduct the manual defect correction, get technical support from the person in charge of Vieworks or a certified engineer by Vieworks. Rev.1.0 Page 111 of 151 VW40-153-006 VIVIX-S 1717N User Manual Functions of Manual Defect Detection Function Description Show Apply Decides whether to indicate the selected defect on the image Decides whether to apply Defect in the list to the calibrated image. All Applies to all coordinates of defects added to the list Selected Applies to relevant coordinates of the selected defects from the list only. Auto Defect Finder Performs the auto defect correction. Delete Add Pixel Add V-Line Add H-Line Deletes the selected items from the list. Adds one defect pixel to Defect Map List. Adds vertical line type of defect pixels to Defect Map List Adds horizontal line type of defect pixels to Defect Map List. Delete Pixel Deletes the defect pixel of a point on list of Defect Map. Delete V-Line Deletes the defect pixel of vertical line on list of Defect Map. Delete H-Line Deletes the defect pixel of horizental line on list of Defect Map. ROI Zoom W/L Pan 1:1 Fit Marks the area of interest. Zoom in or out the image. Adjusts the window level of the image to change the brightness. Moves the image to a desired location. Displays the image as 1:1 ratio. Displays the image as fitting it on the screen. Save and Close Saves the changed defect pixel information as Defect map data. Close Closes the window without saving the changed defect pixel information Rev.1.0 Page 112 of 151 VW40-153-006 VIVIX-S 1717N User Manual 7. Diagnosis, Inspection and Maintenance This section gives information about diagnosis, inspection & maintenance of the product. Diagnosis Product Inspection Cleaning and Disinfection Product Initialization Replacing the Fuse of SCU Rev.1.0 Page 113 of 151 VW40-153-006 7.1 Diagnosis 7.1.1 Image Diagnosis VIVIX-S 1717N User Manual Check the image quality through Diagnosis tools after installing the detector or before usage. If the problems with regard to products or image occur during diagnosis, try to do a calibration again. If the problems are not solved, consult the sales representative in Vieworks or a service engineer. You can acquire and review an image from the Image window in VIVIX Setup program. You can review images by acquiring them through real exposure or getting Dark image by clicking Get Normal Image button. The number of images, pixel value and ROI value will be displayed. The effective area or whole area of an image can be checked. It is also available to check the image by changing its direction. Save the reviewed image as a raw one to analyze. You can acquire an image either applying Offset / Gain data or not.
[TBD] Screen Shot Diagnostic Functions Item Pan Zoom W/L Fit Description Press and drag a mouse button to move the image to the desired position. Press and hold a mouse button to move the image upwards or downwards for expanding / reducing the image. Press and hold a mouse button to move the image to up/down/right/left for adjusting its window level. This function can be used without clicking W/L button, but with the right mouse button basically. Sets the image to the center, which was moved by using Pan function. Clicks and drags the left mouse button to set arbitrary area. The coordinate, min/max Statistic value, average and standard deviations are displayed on Pickup ROI at the left side ROI Zoom of image. Clicks and drags the left mouse button to set window level automatically on a basis of min/max value of the configured area. Expands the image X1 X2 X4 2 times 4 times 16 times Offset Applicability of Offset data Rev.1.0 Page 114 of 151 VW40-153-006 VIVIX-S 1717N User Manual Gain On Off On Off Acquires an image with applying Offset data. Acquires an image without applying Offset data. Applicability of Gain data Acquires an image with applying Gain data. Acquires an image without applying Gain data. Effective Area Applicability of Effective Area in Detector Configuration dialog. On Off Applies effective area of the detector to the image. Applies whole area of the detector to the image. Direction Applicability of Detector Direction Compensation in Detector Configuration dialog. On Off The image is displayed according to the configured direction. The image is displayed as a default direction. The image starting point (0,0) is located on the left top of the image. Get Backup Image Imports or deletes the backed-up images. Get Normal Image Acquires a dark image without X-ray shooting. Save Image Saves the image as a raw one. Close Closes the Diagnosis dialog. You can only change the displayed direction of an image in VIVIX Setup program from Detector Direction Compensation. The direction of an original image cannot be changed. Rev.1.0 Page 115 of 151 VW40-153-006 7.1.2 Battery Pack Diagnosis VIVIX-S 1717N User Manual Install the battery pack to the detector and check the voltage and remaining amount of the battery pack. Furthermore, always check the remaining amount of the battery pack during use of the detector. If performance of the battery pack has some problems, consult the sales representative in Vieworks or a relevant engineer. The battery pack belongs to consumables which performance will be decreased as time passed. Make sure to check the battery life during usage. Check remaining amout of battery pack The battety remains is noticed as a level or percentage (%). Check the battery status from the Information tab of the Diagnosis dialogue in VIVIX Setup program. It is also available to check the battery remains from the LED on the side of detector. You can check the battery remains from VXvue (Vieworks Viewer) or VIVIX SDK. Item Description Equipped The install state of a battery pack. (Equipped / Not Equipped) Charging State The charging state of a batter pack. (Charging / Not Charging) Remain Voltage Battery remains Battery voltage Display of Bettery Remains Level Full Half Quarter Half Quarter Low Unknown Value Battery Remains LED Display 5 4 3 2 1 0 81% ~ 100%
61% ~ 80%
51% ~ 60%
31% ~ 50%
11% ~ 30%
1% ~ 10%
5th level 4thlevel 3rd level 2nd level 1st level Blink Off Rev.1.0 Page 116 of 151 VW40-153-006 VIVIX-S 1717N User Manual If the remaining of battery is under 30% or at the 1st level, the detector LED for noticing battey remains changes from green to orange color. The warning information related to battery remains is displayed from VXvue. The warning information related to battery remains is noticed from VIVIX SDK. If the remaining of battery is under 10%, the detector LED for noticing battey remains blinks in orange color. If the remaining of battery is under 30% or at the 1st level, the system warns low battery and the detector will be turned off automatically if the battery is being consumed for a specific period of time. Therefore, it is recommended to change the battery when a warning message or indicator is displayed. 7.1.3 Wireless Communication Diagnosis In case of using the detector with wireless communication way, make sure to check the status of wireless communication before starting to use. If the status of wireless communication is bad, the speed of acquiring images will be very slow or failed to acquire images. Try to check the surrounding wireless communication status not to occur communication interference. If wireless communication module in the detector has problems, consult the sales representative in Vieworks or a relevant engineer. Check the Connection Status Check the wireless communication state from the Information tab of the Diagnosis dialogue in VIVIX Setup program. User can check the connection status of wired or wireless detector through VXvue or VIVIX SDK. Item Description Connection Type Indicates the connection mode. (Wireless / Tether) Link Speed Link Quality Signal-level Bit rate Rev.1.0 Connection status in the wired mode. (1000Mbps / 100Mbps) Link Quality (Status of the connection quality) value Singal strength Transmission / reception speed Page 117 of 151 VW40-153-006 VIVIX-S 1717N User Manual Frequency Frequency of the connected AP (Access Point) Check the Strength of Wireless Communication Signal The signal strength of wireless communication is provided as 6 stages (0 ~ 5). Level Very Good Good Normal Bad Very Bad Unknown Level Link Quality Meaning 5 4 3 2 1 0 66 ~ 70 56 ~ 65 41 ~ 55 31 ~ 40 1 ~ 30 0 The communication is running smoothly, and it ensures performace of the image acquisition. The communication status is normal, but it does not ensure performace of the image acquisition. The communication status can become unstable. Impossible to communicate normally. The communication is disconnected. The communication is not running smoothly when the strength of wireless communication is under the 2nd stage. Therefore, it is required to check the surrounding wireless communication status. 7.1.4 Communication Speed Diagnosis The communication speed can be diagnosed from the Information tab of Diagnosis dialogue in VIVIX Setup program. Item Description Image Transmission Time Image transfer rate test Download Download speed of the image (Detector Workstation) Throughput Measurement Transmission measuring test Time Bit rate Transmission time Transmission rate Rev.1.0 Page 118 of 151 VW40-153-006 7.2 Product Inspection VIVIX-S 1717N User Manual To use products safely, make sure to check the products before use. If problems occur during inspection or the product is impossible to repair, consult the sales representative in Vieworks or a relevant engineer. 7.2.1 Daily Inspection Before or after using the detector and other surrounding devices, check below items daily. Item Description Ensure that there are no loose screws or breaks. Detector Ensure that there is no dust or foreign matter on the battery bay connector. Ensure that there are no breaks or short-circuits in the battery bay connector. SCU Check if the antenna is damaged. Ensure that cables are not damaged and cable jackets are not torn. Cable Ensure that the power cord plugs are securely connected to both AC inlet and AC outlet of the equipment. 7.2.2 Performance Inspection Check the detector and other devices periodically as follows. Item Period Description Self-Diagnosis Half-yearly Resolution Half-yearly Conduct Self-Diagnosis of the VIVIX Setup program for the internal devices of the detector and check the status. Check the resolution of the detector through resolution chart or using a phantom. Sensitivity Half-yearly the images made by X-ray dose amount reaching to the surface of the Evaluate the characteristic of the detector through checking gray value of detector. Updating calibration data. (Offset Gain Defect) Calibration Half-yearly Proceed to calibrate when X-ray Generator, Tube, Collimator or exposure environment are changed. Self-diagnosis and resolution can be conducted by a user or a service engineer. Sensitivity and calibration should be conducted by an authorized service engineer who Vieworks grants. Rev.1.0 Page 119 of 151 VW40-153-006 7.3 Self Diagnosis VIVIX-S 1717N User Manual You can perform self-diagnosis of the detector and SCU from the Self Diagnosis tab of the Diagnosis dialogue in VIVIX Setup. 1 Choose a desired item to diagnose. 2 Click Execute Test button located at the bottom of the Test Case window. 3 Check the progress and result of diagnosis for each item in the Result window. 4 Click Save to File to save the diagnosis result as a file when the self diagnosis is completed. 7.3.2 Self-Diagnosis Items of Detector and Measures Voltage Item Form Expected problem Measures DDC Decision Defective tether interface cable Change a tether cable. Poor power supply to the wired operation mode. Contact a service engineer. MAIN Decision Poor power supply to the processor. Contact a service engineer. SIGNAL Decision Poor power supply to FPGA. Contact a service engineer. Rev.1.0 Page 120 of 151 VW40-153-006 VIVIX-S 1717N User Manual Battery Item Form Expected problem Measures The battery is not attached. Check if a battery is inserted. Detection Decision A defective ciruit is connected to a battery pack. Voltage Information N/A Remain Information N/A Wireless Contact a service engineer. N/A N/A Item Form Expected problem Measures Detection Decision Defective wireless module Contact a service engineer. Connection Decision communication. between a detector and SCU. Inconsistent environment of the wireless Check obstacles and distance Defective wireless module Contact a service engineer. Sensor Item Form Expected problem Measures Impact Sensor Decision Defective shock sensor Contact a service engineer. Temperature Decision Defective temperature sensor Contact a service engineer. AED Decision Defective AED sensor Contact a service engineer. Memory Item Form Expected problem Measures Not available to save backup images. Contact a service engineer. Detection Decision Not available to save logs. Contact a service engineer. File system Decision The calibration data is inapplicable. Contact a service engineer. Not available to save backup images. Contact a service engineer. Not available to save logs. Contact a service engineer. Status Information N/A N/A IC Item FPGA Form Expected problem Measures Decision Not available to take images from a detector. Contact a service engineer. Fuel Gauge Decision Not available to check the remaining of a battery pack. Contact a service engineer. Rev.1.0 Page 121 of 151 VW40-153-006 VIVIX-S 1717N User Manual 7.3.3 Self-Diagnosis Items of SCU and Measures Wireless Item Form Expected problem Measures Detection Decision Defective wireless module Contact a service eingineer. Memory Item Form Expected problem Measures Detection Decision Not available to save logs. Contact a service eingineer. File system Decision Not available to save logs. Contact a service eingineer. Status Information N/A N/A IC Item Form Expected problem Measures Switching IC Decision Current Controller Decision Not available to connect the detector and PC. Not available to block overcurrent when using the wired mode. Contact a service eingineer. Contact a service eingineer. Rev.1.0 Page 122 of 151 VW40-153-006 VIVIX-S 1717N User Manual 7.4 Cleaning and Disinfection After using the detector and peripheral equipments for examination, use germicidal disinfecting wipes or cloth with mild diluted disinfectant detergent to clean surfaces of the product. Recommended Detergent Foam Recommended disinfectant wipe Wip anios manufactured by Anios Sani-cloth Active Wipes by PDI Recommended disinfectant product Sulfasafe Storage temperature: 5C ~ 35C How to Use Detergent Foam 1 Prepare the disinfectant detergent and a clean and dry non-woven cloth. 2 Use the spray bottle to spray detergent to the cloth and clean the equipment. 3 After it has been cleaned, leave the equipment un-used for 15 minutes. 4 Conduct cleaning once a week or in case of contamination. Do not re-use wipes. Be careful to use disinfectant detergent which can cause irritation to eyes and skin. Use in well-ventilated areas, and wear gloves at all times. Do not clean the equipment with its power on. Do not use abrasive brush and scraper to clean the product. Be careful not to make liquid soak when cleaning battery bay and the connector on the side of products. Other Disinfectant detergent compliant to conditions listed below may be used following proper procedures according to its own manual. European Biocidal Products designed for surface disinfection (Directive 98/8/EC) Detergent with composition of Didecyldimethylammonium chloride, polyhexamethylene biguamide hydrochloride. Rev.1.0 Page 123 of 151 VW40-153-006 7.5 Product Initialization VIVIX-S 1717N User Manual If the connection status of system is not stable or setting value is not correct, user can initialize the products. 7.5.1 SCU Initialization 1 Click Configuration button of SCU after running the VIVIX Setup program. 2 Click Factory Reset button in Configuration dialogue. 3 Wait for SCU to be initialized and rebooted automatically. 4 Check whether SCU initialization is completed. Default value of SCU initialization Item Network Default Value IP Address 169.254.2.100 Subnet Mask 255.255.0.0 Gateway 169.254.2.100 AP Trigger AP On/Off Frequency Country Band Channel SSID Key Method Polarity ON 5 KR 40
+36 vivix 1234567890 Packet Auto Rev.1.0 Page 124 of 151 VW40-153-006 7.5.2 Detector Initialization VIVIX-S 1717N User Manual 1 Click Configuration button of Detector after running the VIVIX Setup program. 2 Click Factory Reset button in Configuration dialogue. 3 Wait for Detector to be rebooted automatically. 4 Check whether detector initialization is completed. Default value of detector initialization Item Network Default Value IP Address 169.254.1.10 Subnet Mask 255.255.0.0 Gateway 169.254.2.100 WNetwork AP SSID Key AP Scan AP On/Off Frequency Country Band Channel SSID Key Test Pattern Type Image Timeout Time Power Management Sleep Sleep After Shut Down vivix 1234567890 OFF OFF 5 KR 40
+36 vivix_ap 1234567890 20 sec. Disable OFF 10 min. OFF Shut Down after 30 min. Power Control By Detector Rev.1.0 Page 125 of 151 VW40-153-006 VIVIX-S 1717N User Manual 7.5.3 Wireless Initialization of Detector 1 Turn off the detector. 2 Press and hold both the power button and AP button over 3 seconds. 3 Initialization will be conducted when orange LED is flickering, after that, the detector will be turned off automatically. 4 Turn on the detector and check whether detector initialization is completed. Default value of wireless initialization Item Network Default Value IP Address 169.254.1.10 Subnet Mask 255.255.0.0 Gateway 169.254.2.100 WNetwork SSID Key Wireless Only AP AP On/Off Frequency Country Band Channel SSID Key vivix 1234567890 OFF OFF 5 KR 40
+36 vivix_ap 1234567890 When processing the wireless initialization of a detector, only the detectors network information is initialized as a default value. Rev.1.0 Page 126 of 151 VW40-153-006 VIVIX-S 1717N User Manual 7.6 Replacing the Fuse of SCU (SCU Basic only) There are 2 fuses attached on the standard SCU for the purpose of electrical accident precaution, in case of over current from external power input. Stop using the SCU immediately when the fuse is blown. Fuse Information Item Model Type Specifications Littelfuse 218002 (2EA) Time Lag Cartridge Fuse Amp Rating Voltage Rating 2A 250V Pull the plug out and turn all the devices off before changing the fuse. First, resolve the cause why the fuse is blown. Replace the fuse to the one provided as an option (1 set / 2 ea) or to the one with same specifications when the fuse is out. Be careful not to touch both the patient and the fuse holder at the same time or let the patient touch the fuse holder. How to Replace the Fuse No. Description Separate the fuse from the holder located power input port on the back side of standard SCU by pulling the fuse holder. After checking, replace the fuse with correct specifications in case of need.
-
Insert the fuse holder again. 1 2 3 Rev.1.0 Page 127 of 151 VW40-153-006 VIVIX-S 1717N User Manual 8. Troubleshooting This section gives information about troubleshooting. Troubleshooting Rev.1.0 Page 128 of 151 VW40-153-006 8.1 Trobleshooting 8.1.1 Troubleshooting Guide VIVIX-S 1717N User Manual When you encounter problems while using the equipment, search for the table below for the problem or error messages and try the solutions.If the problem persists, turn off the detector and consult your sales representative or a distributor. Please refer to the details of the following symptoms or error messages. Troubleshooting must be performed by service engineer who is authorized by Vieworks. If an unqualified person performs troubleshooting on the system resulting in damaging the detector, software or hardware, then the Vieworks or its representative is not responsible for the detector repair regardless of remain warranty. For more detailed information, refer to <10.1 Service Information> and <10.2 Warranty>. 8.1.2 Failed to Turn the Detector On Symptom Failed to turn on the power of the detector. Expected Causes Not installing a battery pack properly. Dead battery pack Battery pack or the detector is broken down. Solutions 1 Install battery pack 2 Charge battery pack 3 Check the result after getting rid of the battery pack and connecting the tether cable. 4 Replace other battery packs and check the result of it. 5 Replace another detector and check the result of it. 6 Replace corresponding devices. 8.1.3 The Power Switch of SCU or Status LED is not worked Symptom The power switch of Basic SCU or SCU mini is not working. The status LED of SCU is not responding. Expected Causes Power cable is broken down. Errors in the fuse Internal circuit is broken down. Rev.1.0 Page 129 of 151 VW40-153-006 Solutions VIVIX-S 1717N User Manual 1 Check the connection between AC power cable and SCU Basic. 2 Check the connection between DC power cable and SCU mini. 3 Turn off the power switch and turn on again and then check the fan or status of back side. 4 Replace another SCU and check the result of it 5 Replace the fuse of standard SCU. (refer to <7.6 Replacing the Fuse of SCU (SCU Basic only)>) 6 Replace corresponding devices. 8.1.4 Communication Test is failed Symptom Transmission error is occurred, failure of communication test is occurred. Expected Causes Network connection problem Network setting problem PC environment setting problem Wireless environment environment problem Devices error Solutions 1 Check the connection of network cable between Workstation and SCU. 2 Check if the accurate network cable is used or not. (CAT 5E or 6) 3 Set the network information of Workstation, SCU and detector again. 4 Check whole workstation environment again such as firewall setting and release the power save mode. 5 Check surrounding wireless communication environment. 6 Boot up detector and SCU again by processing initialization. (Refer to <7.5 Product Initialization>.) 7 Replace other SCU and Detectors and check the result of it 8 Replace corresponding devices. 8.1.5 The Active LED and Data LED of the Detector are blinking Symtom The active LED and data LED is blinking when power LED is ON. Expected Causes Detector registeration error Data transmission error Solutions 1 Turn on SCU again 2 Check the network cable connection 3 Check the workstation environment and network information again 4 Check if the surrounding wireless communication is good Rev.1.0 Page 130 of 151 VW40-153-006 VIVIX-S 1717N User Manual 5 Check cable connection again when connected with tether interface cabel 6 Replace other devices and check the result of it 7 Replace corresponding devices. 8.1.6 Errors in Detector LED Symptom All LED lamps of detector are blinking. 2 LED lamps of detector are blinking and remaining is blinking slowly. Expected Causes Internal hardware errors of the detector. Solutions 1 Boot up the detector again and check the result of it 2 Replace the detector. 8.1.7 Rapid Consumption of Battery Symptom Consumption of fully charged battery pack is fast. Expected Causes Performance decrease caused by usage of long time. Usage of battery pack in low temperature environment. Solutions 1 Replace to new battery pack if the battery pack has been used for a long time. (Battery pack is consumables) 2 Use battery pack in room temperature environment. Charging capacity of battery pack in low temperature environment will be decreasing. 8.1.8 Battery Pack or Installation Part of Battery is Getting Hot Symptom Battery pack or compartment for installation of battery pack is getting hot. Expected Causes Battery pack failure Detector Failure Solutions 1 Do not use battery pack 2 Consult with service engineers of Vieworks. Rev.1.0 Page 131 of 151 VW40-153-006 VIVIX-S 1717N User Manual 9. Regulatory Information This section gives explanation about the regulatory information and standard related to the products Medical Equipment Safety Standards Radio Frequency Compliance Information Labels and Symbols Guidance and Manufacturer Declaration for EMC Rev.1.0 Page 132 of 151 VW40-153-006 VIVIX-S 1717N User Manual 9.1 Medical Equipment Safety Standards 9.1.1 Medical Equipment Classification Item Description Type of protection against electrical shock Class equipment Internally powered Degree of protection against electrical shock Type B Degree of protection against ingress of water IPX3 Operation mode Continuous operation Flammable anesthetics anesthetic mixture with air or with oxygen or nitrous NOT suitable for use in the presence of a flammable oxide. 9.1.2 Product Safety Standard South Korea
, : IEC 60601-1 2009-137 .
: IEC 60601-1-2 .
(EMI)
(EMS) 2009-54 1 A 1 5.1 2009-54 1 () 2009-54 1 A 1 5.2 2009-54 1 ()
(ESD) 2009-54 2 36.202/36.202.2/ KN61000-4-2 RF 2009-54 2 36.202/36.202.3/ KN61000-4-3
(EFT) 2009-54 2 36.202/36.202.4/ KN61000-4-4
(Surge) 2009-54 2 36.202/36.202.5/KN61000-4-5 RF 2009-54 2 36.202/36.202.6/ KN61000-4-6 2009-54 2 36.202/36.202.7/KN61000-4-11
, Rev.1.0 Page 133 of 151 VW40-153-006 U.S.A / Canada Item VIVIX-S 1717N User Manual IEC 60601-1(ed.2 am1+ am2+ co1) Medical electrical equipment- Part1: General requirements for safety UL 60601-1(ed.2)
-
CSA-C22.2 No. 601-1-M90 (R2006) IEC 60601-1-2: 2007 (ed.3) IEC 60601-1-4: 2000 (ed.1.1) IEC 62304:2006 ISO 14971:2012 Medical electrical equipment Part 1: General requirements for safety
(adopted amendment 2:1995 to IEC60601-1) Medical electrical equipment-Part 1-2: Collateral standard:
Electromagnetic compatibility Medical electrical equipment- Part 1-4: Collateral Standard:
Programmable electrical medical systems Medical device software-software life cycle processes Medical Device- Application of risk management to medical devices European Union Item MDD (Medical Device Directive) 93/42/EEC as amended by 2007/47/EC EN ISO 13485:2012 Medical devices Quality Management systems Requirements for regulatory purposes EN 60601-1: 2007(ed.3) Medical electrical equipment- Part1: General requirements for safety IEC 60601-1-2: 2007(ed.3) IEC 60601-1-4: 2000(ed.1.1) IEC 62304:2006 ISO 14971: 2012 Medical electrical equipment-Part 1-2: Collateral Standard :
Electromagnetic compatibility-Requirements and tests Medical electrical equipment- Part 1-4: Collateral Standard :
Programmable electrical medical systems Medical device software-Software life cycle processes Medical device Application of risk management to medical devices. Rev.1.0 Page 134 of 151 VW40-153-006 VIVIX-S 1717N User Manual 9.2 Radio Frequency Compliance Information Country Item FCC Part 15.107(b) / Part 15.109(b) U.S.A FCC Part 15 Subpart E 15.407 European Union FCC Part 15 Subpart C 15.247 ETSI EN 301 489-1 V1.9.2:2011 (EMC) ETSI EN 301 489-17 V2.2.1:2012 (EMC) EN 300 328 V.1.8.1; EN 301 893 V1.7.1 (RF) EN 62311:2008 (RF Exposure) KS C IEC 60601-1-2:2007 South Korea IEC 61000-3-2:2005+A1:2008+A2:2009 IEC 61000-3-3:2008 9.2.1 FCC Compliance This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Operation is subject to the following tow conditions. This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measure. Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from where the receiver is connected. Consult the distributor or an experienced radio/TV technician for help. Change or modification which is not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. 5.15-5.35G band is restricted to indoor operations only. The SAR limit set by the FCC is 1.6 W/kg. The highest SAR value for this model when tested for use at the front is 0.081 W/kg. The front side of a detector should be used for image acquisition. Rev.1.0 Page 135 of 151 VW40-153-006 9.2.2 FCC SAR KDB 865664 D01 v01r03 9.2.3 CE R&TTE SAR Item VIVIX-S 1717N User Manual EN 62311:2008 Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields. (0 Hz - 300 GHz) Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices Human models, instrumentation, and procedures. Part 1: Procedure to determine the specific absorption rate (SAR) for hand-held devices used in close proximity to the ear (frequency range of 300 MHz to 3 GHz). Human Exposure to Radio Frequency Fields from Handheld and Body-Mounted Wireless Communication Devices Human models, Instrumentation, and Procedures. Part 2: Procedure to determine the specific absorption rate (SAR) for mobile wireless communication devices used in close proximity to the human body
(frequency range of 300 MHz to 6 GHz). EN 62209-1:2006 EN 62209-2:2010 Rev.1.0 Page 136 of 151 VW40-153-006 9.3 Labels and Symbols VIVIX-S 1717N User Manual The VIVIX-S 1717N detector and relevant components have labels attached on them. The contents and locations of each label are indicated below. 9.3.1 Label VIVIX-S 1717NA / 1717NB (Wired Detector) Rev.1.0 Page 137 of 151 VW40-153-006 VIVIX-S 1717NAW / 1717NBW (Wireless Detector) VIVIX-S 1717N User Manual Rev.1.0 Page 138 of 151 VW40-153-006 VIVIX-S 1717N User Manual Battery Battery Charger Rev.1.0 Page 139 of 151 VW40-153-006 SCU Basic (FXRS-02A) VIVIX-S 1717N User Manual Rev.1.0 Page 140 of 151 VW40-153-006 SCU Basic (FXRS-03A) VIVIX-S 1717N User Manual Rev.1.0 Page 141 of 151 VW40-153-006 SCU mini (FXRS-04A) VIVIX-S 1717N User Manual Rev.1.0 Page 142 of 151 VW40-153-006 Outer Box
[TBD]
VIVIX-S 1717N User Manual 9.3.2 Product Serial Number Serial Number Composition The serial numbers for each product or accessory are composed as follows. V 1 D A B J 0 0 1 Item Composition Year Month Serial number Revision will be updated in case of follows. Mass production or a large amount of order. Exterior alteration. Item code will be produced based on internal management standard of vieworks. Composition code is like follows. D: Detector S: SCU C: Battery Charger Range of Serial Number is 001 ~ 999. Initial Per Year 11 AA 12 AB 13 AC 14 AD 15 AE 16 AF 17 AG 18 AH 19 AI 20 BJ Initial Per Month 1 A 2 B 3 C 4 D 5 E 6 F 7 U 8 V 9 W 10 X 11 Y 12 Z Composition of Serial Number for Each Item Model 1717NA 1717NB 1717NAW 1717NBW FXRC-02A FXRS-02A FXRS-03A FXRS-04A Rev.1.0 Composition Serial Number Detector Detector Detector Detector Battery Charger SCU SCU Basic SCU mini VMDAEA001 VNDAEA001 VODAEA001 VPDAEA001 VACAEA001 V3SAEA001 VCSAEA001 VASAEA001 Page 143 of 151 VW40-153-006 9.3.3 Product Symbols Symbol Description Direct current Alternating current Protective earth (Ground) VIVIX-S 1717N User Manual Equipotentiality Power on Power on for part of the equipment Power off Power off for part of the equipment Attention, consult accompanying documents General warning sign Warning sign for electricity This Mark shows compliance with both Canadian and U.S. safety requirements. With Respect to electric shock, fire, and mechanical hazards only. In accordance with UL60601-1 and CAN/CSA C22.2 No. 601.1. This mark shows compliance of the essential requirement and other relevant provisions of Directive 93/42/EEC as amended by 2007/47/EC. Non-ionizing radiation Read and understand all instructions and warning labels in the product documentation before using the equipment. Keep manual for future reference. Dealing with a medicine that can only be given by a prescription from a doctor and you should use a certain medication that a doctor recommended. General mandatory action sign This mark indicates that this equipment must be handled with care. Do not jolt or apply excessive load to the equipment. This is a Type B Applied Part according to UL 60601-1 and EN 60601-1. This mark indicates that the equipment must be collected separately under the Directive on Waste Electrical and Electronic Equipment 2002/96/EC (WEEE) in the European Union. (For European Union) This mark indicates that the battery must be collected separately under the Directive on Waste Electrical and Electronic Equipment 2002/96/EC (WEEE) in the European Union. (For European Union) Rev.1.0 Page 144 of 151 VW40-153-006 VIVIX-S 1717N User Manual 9.4 Guidance and Manufacturers Declaration for EMC This device has been tested for EMI/EMC compliance, but interference can still occur in an electromagnetically noisy location. Attempt to maintain a suitable distance between electrical devices to prevent malfunction. 9.4.1 Electromagnetic Emissions The Equipment Under Test (EUT) is intended for use in the electromagnetic environment specified below. The customer or user of the EUT should assure that it is used in such an environment. Immunity test Compliance Electromagnetic Environment RF Emissions
(CISPR 11) RF Emissions
(CISPR 11) Harmonic emissions
(IEC 61000-3-2) Voltage fluctuations/
The EUT uses RF energy only for its internal function. Therefore, its Group 1 RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. Class B Class A The EUT is suitable for use in all establishments other than domestic and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. Flicker emissions Complies
(IEC 61000-3-3) 9.4.2 Electromagnetic Immunity The VIVIX-S 1717N system is intended for using in the electromagnetic environment specified below. The user of this system should assure that it is used in the following environment. Electrostatic Discharge (ESD) IEC 61000-4-2 Item Description Immunity test Electrostatic discharge (ESD) IEC 61000-4-2 IEC 60601 test condition Compliance Level Contact 6 Air 8 Contact 6 Air 8 Electromagnetic Environment -
Guidance Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30%. Rev.1.0 Page 145 of 151 VW40-153-006 VIVIX-S 1717N User Manual Electrical Fast Transient/Burst IEC 61000-4-4 Item Description Immunity test Electrical fast transient/burst IEC 61000-4-4 IEC 60601 test condition Compliance Level Power supply lines 2 Input / output lines 1 Power supply lines 2 Input / output lines 1 Electromagnetic Environment -
Main power quality should be that of a typical commercial or hospital Guidance environment. Surge IEC 61000-4-5 Item Description Immunity test Surge IEC 61000-4-5 IEC 60601 test condition Compliance Level Differential mode 1 Common mode 2 Differential mode 1 Common mode 2 Electromagnetic Environment -
Main power quality should be that of a typical commercial or hospital Guidance environment. Voltage Dips, Short Interruptions/Voltage Variations on Power Supply Input Lines IEC 61000-4-11 Item Description Immunity test IEC 60601 test condition Compliance Level Voltage dips, short interruptions and voltage variations on power supply input lines IEC 61000-4-11
<5% U (>95% dip in U) for 0.5 cycle. 40% U (60% dip in U) for 5 cycles. 70% U (30% dip in U) for 25 cycles.
<5% U (<95% dip in U) for 5 sec.
<5% U (>95% dip in U) for 0.5 cycle. 40% U (60% dip in U) for 5 cycles. 70% U (30% dip in U) for 25 cycles.
<5% U (<95% dip in U) for 5 sec. Main power quality should be that of a typical commercial or hospital environment. Electromagnetic Environment -
If the user of the EUT image intensifier requires continued operation Guidance during power mains interruptions, it is recommended that the EUT image intensifier be powered from an uninterruptible power supply or a battery. Rev.1.0 U is the AC power prior to approving the test level voltage. Page 146 of 151 VW40-153-006 VIVIX-S 1717N User Manual Power Frequency (50/60 ) Magnetic Field IEC 61000-4-8 Item Description Immunity test Power frequency (50/60 ) magnetic field IEC 61000-4-8 IEC 60601 test condition 3 A/m Compliance Level 3 A/m Electromagnetic Environment -
Power frequency magnetic fields should be at levels characteristic of a Guidance typical location in a typical commercial or hospital environment. Conducted RF IEC 61000-4-6 / Radiated RF IEC 61000-4-3 Item Description Immunity test Conducted RF IEC 61000-4-6 Radiated RF IEC 61000-4-3 IEC 60601 test condition 3 Vrms 150 to 80 3 V/m 80 to 2.5 Compliance Level 3 Vrms 150 to 80 3 V/m 80 to 2.5 Portable and mobile RF communications equipment should be used no closer to any part of the EUT, including cables, than the recommended separation distance calculated from the below equations applicable to the frequency of the transmitter. Electromagnetic P is the maximum output power rating of the transmitter in watts (W) Environment - Guidance according to the transmitter manufacturer and d is the recommended separation distance in meters (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site surveya, should be less than the compliance level in each frequency range b. Interference may occur in the vicinity of equipment marked with the symbol. At 80 and 800 , the higher frequency range applies. These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which EUT is used exceeds the applicable RF compliance level above, EUT should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating EUT. Over the frequency range 150 to 80 , field strengths should be less than [V1] V/m. Rev.1.0 Page 147 of 151 VW40-153-006 VIVIX-S 1717N User Manual 10. Information This section gives overview information for service and warranty of the product. Service Information Warranty Revision History Rev.1.0 Page 148 of 151 VW40-153-006 10.1 Service Information 10.1.1 Product Lifetime VIVIX-S 1717N User Manual The estimated product lifetime may be up to five (5) years under the appropriate regular inspection and maintenance. 10.1.2 Regular Inspection and Maintenance In order to ensure the safety of patients, operating personnel and third parties, and to maintain the performance and reliability of the equipment, be sure to perform regular inspection at least once a year. If necessary, clean up the equipment, make adjustments, or replace consumables. There may be cases where overhaul is recommended depending on the conditions. Contact your sales representative or distributor for regular inspections or maintenance. 10.1.3 Repair If a problem cannot be solved even after taking the measures indicated in Troubleshooting and contact your sales representative or a distributor for repairs. Please refer to the name label and provide the following information. Model name FXRD-1717NA / FXRD-1717NB FXRD-1717NAW / FXRD-1717NBW Serial number 9 digit-number on the product label Explanation of problem Describe as detailed as possible. 10.1.4 Replacement Parts Support Performance parts (parts required to maintain the functioning of the product) of this product will be stocked for seven years after discontinuance of production, to allow for repair. 10.1.5 Consumables The following consumable can deteriorate because of its characteristics and structure. For purchase of consumables, contact your sales representative or distributor. Battery pack: FXRB-02A Rev.1.0 Page 149 of 151 VW40-153-006 10.2 Warranty VIVIX-S 1717N User Manual Vieworks warrants that this product will be free from defects in materials and workmanship for a period of 24 months from the date of delivery. If any such product proves defective during this warranty period, Vieworks at its option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product. In order to obtain service under this warranty, Customer must notify Vieworks of the defect before the expiration of the warranty period and make suitable arrangements for the performance of service. Customer shall be responsible for packaging and shipping the defective product to the service center designated by Vieworks with shipping charges prepaid. Vieworks shall pay for the return of the product to customer if the shipment is to a location within the country in which Vieworks designated service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations. This warranty shall not apply to any defect, failure, or damage caused by improper or inadequate maintenance and care. Vieworks shall not be obligated to furnish service under this warranty to repair damage resulting from attempts by personnel other than Vieworks or its representatives to install, repair, or service this product, to repair damage resulting from improper use or connection to incompatible equipment or power source; or to service a product that has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty of servicing the product. THIS WARRANTY IS GIVEN BY VIEWORKS WITH RESPECT TO THIS PRODUCT IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. VIEWORKS AND ITS VENDOR DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABLILITY OR FITNESS FOR A PARTICULAR PURPOSE. VIEWORKS RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. VIEWORKS AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER VIEWORKS OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES. There are no warranties which extend beyond the description mentioned in this document Rev.1.0 Page 150 of 151 VW40-153-006 VIVIX-S 1717N User Manual 10.3 Revision History Version Date Descriptions 1.0 2015-03-??
Initial Release Vieworks Co., Ltd.
(Gwanyang-dong) 41-3, Burim-ro 170beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do, 431-060 Republic of Korea Telephone: +82-70-7011-6161 Fax: +82-31-386-8631 Homepage: http://www.vieworks.com European representative: DONGBANG ACUPRIME 1 Forrest Units, Hennock Road East, Marsh Barton, Exeter EX2 8RU, UK Telephone: +44(0)-1392-829500 Homepage: http://www.acuprime.com Rev.1.0 Page 151 of 151 VW40-153-006
1 2 | Internal Photos | Internal Photos | 1.51 MiB | April 30 2015 |
www.kes.co.kr EUT Internal photographs Detector Inside Detector Inside(Metal shield removed) Model No.: FXRD-1717NAW Page 1 of 15 www.kes.co.kr Antenna Location Antenna Zoom1 Model No.: FXRD-1717NAW Page 2 of 15 www.kes.co.kr Antenna Zoom2 AED board (Top) Model No.: FXRD-1717NAW Page 3 of 15 www.kes.co.kr AED board (Bottom) BATT board(Top) Model No.: FXRD-1717NAW Page 4 of 15 www.kes.co.kr Model No.: FXRD-1717NAW BATT board(Bottom) Control board(Top) Page 5 of 15 www.kes.co.kr Model No.: FXRD-1717NAW Control board(Bottom) Gate Board(Top) Page 6 of 15 www.kes.co.kr Model No.: FXRD-1717NAW Gate Board_Zoom 1(Top) Gate Board_Zoom 2(Top) Page 7 of 15 www.kes.co.kr Gate Board(Bottom) Gate Board_Zoom 1(Bottom) Model No.: FXRD-1717NAW Page 8 of 15 www.kes.co.kr Gate Board_Zoom 2(Bottom) Signal Board(Top) Model No.: FXRD-1717NAW Page 9 of 15 www.kes.co.kr Signal Board_Zoom 1(Top) Signal Board_Zoom 2(Top) Model No.: FXRD-1717NAW Page 10 of 15 www.kes.co.kr Signal Board(Bottom) Signal Board_Zoom 1(Bottom) Model No.: FXRD-1717NAW Page 11 of 15 www.kes.co.kr Signal Board_Zoom 2(Bottom) CC30 Board (Top) Model No.: FXRD-1717NAW Page 12 of 15 www.kes.co.kr CC30 Board (Shields removed_Top) CC30 Board (Bottom) Model No.: FXRD-1717NAW Page 13 of 15 www.kes.co.kr RF Module(Top) RF Module(Bottom) Model No.: FXRD-1717NAW Page 14 of 15 www.kes.co.kr RF Module(Shields removed_Top) RF Module(shields removed_Bottom) Model No.: FXRD-1717NAW Page 15 of 15
1 2 | External Photos | External Photos | 74.98 KiB | April 30 2015 |
www.kes.co.kr EUT External photographs Front Rear Model No.: FXRD-1717NAW Page 1 of 2 www.kes.co.kr Edge 1 Edge 2 Model No.: FXRD-1717NAW Page 2 of 2
1 2 | Label Info | ID Label/Location Info | 86.55 KiB | April 30 2015 |
Label and Location Contains FCC ID : RYK-WPEA-121N Contains FCC ID : RYK-WPEA-121N PFRFXRD-1717NAW PFRFXRD-1717NAW Model No.: FXRD-1717NAW Page 1 of 1
1 2 | Agent Authorization Letter | Cover Letter(s) | 25.21 KiB | April 30 2015 |
Date: April, 10. 2015 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 To whom it may concern:
I, the undersigned, hereby authorize KT Kang of KES Co., Ltd. and hereafter referred to as KES Co., Ltd., to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by KT Kang of KES Co., Ltd. on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). In authorizing KES Co., Ltd. as our agent, we still recognize that we are responsible to:
a) b) c) d) e) f) g) comply with the relevant provisions of the certification program;
make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints;
make claims regarding certification only in respect of the scope for which certification has been granted;
do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized;
upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division;
use certification only to indicate the products are certified as being in conformity with specified standards;
endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner;
h) i) j) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division;
keep a record of all complaints made known to the us relating to the products compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested;
take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification;
k) document the actions taken. This authorization is valid until further written notice from the applicant. Sincerely Yours, Assistant Manager / Youjeong Kim REMARK:
1. 2. 3. This authorization letter will be sent along with your application when filing with the Certification Division. Please follow the format and type it on company letterhead and send original to us. Authorized signature must be in agreement with grantee code contact in FCC database.
1 2 | Antenna Specification | Operational Description | 1.00 MiB | April 30 2015 |
Vieworks Co., Ltd. Vieworks 2012-01 Antenna PCB Dual-Band Antenna (Wi-Fi 2.4/5GHz) PRODUCT APPROVAL SHEET Version : 2.0 Model Vieworks 2012-01 Dual Band PCB Antenna Part Number Description Sales D AEi-2450/5500DP-C1.13[Vieworks]
Dual-Band(2.4/5GHz) /PCB /I-Pex Rodem Microsystem Suppliers Writer Review Approval Customer Approved by RODEM MICROSYSTEM CO., LTD. RODEM MICROSYSTEM CO., LTD. RODEM MICROSYSTEM CO., LTD. RODEM MICROSYSTEM CO., LTD.
(448-808) #401, Sangsaeng B/D, 253-1, Jukjeon-ro, Suji-gu, Yongin-si, Gyeonggi-do, KOREA Office : +82-31-715-9309 | Fax : +82-505-329-9309 E-mail : sales@rodemsys.co.kr | Website : www.rodemsys.co.kr Vieworks 2012-01 Antenna - PRODUCT APPROVAL SHEET Revised History Version V 1.0 V 2.0 Purpose Initial Doc Date Editor 2012/05/11 Bae Jae-Kyun Gain & Measurement 2012/10/04 Bae Jae-Kyun 2 Vieworks 2012-01 Antenna - PRODUCT APPROVAL SHEET 1. SPECIFICATION 1.1. Model : AEi2450/5500DP-C1.13[Vieworks]
1.2. Application This specifications are specified for the Wi-Fi dual band PCB antenna. 1.3. ANTENNA conditions of use Portable Stationary Mobile Outdoor Indoor etc. ( ) 1.4. ANTENNA shape Refer to the attached drawings. 1.5. Electrical characteristics and performance Working conditions or their equivalent state must be satisfied the following. ELECTRICAL SPECIFICATIONS MODEL
(MHz) V.S.W.R GAIN(dBi) - 2.4GHz GAIN(dBi) - 5.2GHz(5150~5350) GAIN(dBi) - 5.6GHz(5470~5725) Max Input Power Input Impedance POLARIZATION AEi-2450/5500DP-C1.13[Vieworks]
2.4~2.5GHz / 5.2~5.8GHGz LESS THAN 1 : 5.0 2.5dBi
[ Composite Gain : 4.3 dBi]
1.99dBi [ Composite Gain : 4.7 dBi]
2.19dBi [ Composite Gain : 5.0 dBi]
5 [W]
50 []
Isotropic 1.6. Mechanical specifications and properties MECHANICAL SPECIFICATIONS TYPE RADIATION TYPE CONNECTOR TYPE CABLE MATERIAL DIMENSION REMARK GOLD-PLATING BLACK-Color SPEC FR-4 Dipole PCB U.FL 1.13 , 300mm FR-4, 0.8T 44 x 10 x 0.8mm OPERATING TEMPERATURE()
-30 ~ +70 3 Vieworks 2012-01 Antenna - PRODUCT APPROVAL SHEET 1.7. Other performance and properties 1.7.1 Anti-shock With combining the antenna, applying the peak to peak amplitude 1mm vibration, swept frequency to 5~55Hz at 1 minute intervals, in vertical and horizontal, left and right, forward and backward directions for 2 hours, it is measured. It should be no problems in each part. It is satisfied with the characteristics and performance of the clause 5. 1.7.2 Temperature Properties The antenna is measured after being left for 96 hours at -30 and 70 respectively. It should be no problem such as separation, modification in each part. It is satisfied with the characteristics and performance of the clause 5. 1.7.3 Humidity Properties The antenna is measured after being left for 96 hours at ambient temperature 40 and relative humidity 90~95%. It should be no problem in appearance, on the structure in each part. It is satisfied with the characteristics and performance of the clause 5. 1.8. Measurement and Inspection It should be appropriate for specifications and requirements in this approval sheet, and also suitable for quality management regulations of our company. However, clause 7 may be omitted by agreement of the buyer. 1.9. Packaging The product has to do assembly packaging not to do movement of the boxes after doing individual packaging. 1.10. Assurance If any part of the product proves to be defective, is determined to be defective design or manufacturing, within one year of the date of purchase, it is under an obligation to repair or replace free of charge, immediately. 4 Vieworks 2012-01 Antenna - PRODUCT APPROVAL SHEET 2. Measurement 2.1. Measurement Antenna installation for measuring antenna gain, radiation pattern.
- Calibration frequency band : 2.4 ~ 6.0[GHz]
- Radiation pattern angle step : 05 The upper side Antenna The left side Antenna 5 Vieworks 2012-01 Antenna - PRODUCT APPROVAL SHEET 3. SPEC Data 3.1. Radiation Pattern / The left side - 2.4GHz 6 Vieworks 2012-01 Antenna - PRODUCT APPROVAL SHEET 3. SPEC Data 3.2 Radiation Pattern / The left side - 5GHz 7 Vieworks 2012-01 Antenna - PRODUCT APPROVAL SHEET 3. SPEC Data 3.3. Radiation Pattern / The upper side 2.4GHz 8 Vieworks 2012-01 Antenna - PRODUCT APPROVAL SHEET 3. SPEC Data 3.4. Radiation Pattern / The upper side 5GHz 9 Vieworks 2012-01 Antenna - PRODUCT APPROVAL SHEET 4. INPUT Impedance 4.1. Input Impedance Matching (VSWR)
<4.1 Left Antenna - VSWR>
<4.2 Upper Antenna - VSWR>
10 Vieworks 2012-01 Antenna - PRODUCT APPROVAL SHEET 5. Antenna Dimension 11 Vieworks 2012-01 Antenna - PRODUCT APPROVAL SHEET 6. Antenna Image 12
1 2 | Attestation Letter | Attestation Statements | 30.80 KiB | April 30 2015 |
AT ATTESTA CC ID :
For F ATION PFRFXR LETTE RD-1717 ER 7NAW ssion on, Applicati ion Processin ng Branch Communica ent Authoriz akland Mills ia, MD 2104 0, 2015 ation Commis zation Divisio Road 48 OM IT MAY Y CONCERN N mpany Viewo dule (FCC ID orks Co., Ltd D:RYK-WPE d. Product F A-121N) do FXRD-1717N es not use D NAW (FCC FS band. ID:PFRFXRRD-1717NAWW) in the Federal Equipme 7435 Oa Columb April 10 TO WH The com RF mod Best reg gards, Compan Type Na Title : A ny : Viework ame : Youjeo Assistant Man s Co., Ltd. ong Kim nager
1 2 | Confidentiality Request | Cover Letter(s) | 14.59 KiB | April 30 2015 |
Date: April 10, 2015 Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: PFRFXRD-1717NAW Pursuant to Sections 0.457 and 0.459 of the Commissions Rules, we hereby request confidential treatment of information accompanying this application as outlined below:
Exhibit Type Part List Schematics Diagram(s) Block diagram Operation description File Name CONF APPENDIX_FXRD-1717NAW_Part List.PDF CONF APPENDIX_ FXRD-1717NAW _Schemetics.PDF CONF APPENDIX_ FXRD-1717NAW _Block diagram.PDF CONF APPENDIX_ FXRD-1717NAW _Operation description.PDF The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, Youjeong Kim / Assistant Manager
1 2 | Cover Letter | Cover Letter(s) | 33.26 KiB | April 30 2015 |
Viewo gil, Dongan-
+82-70-4496 orks Co
-gu, Anyang-
6-1860 / Fax:
o., Ltd. gi-do, Republ
-si, Gyeongg
+82-31-386 6-8631 lic of KORE EA 4 41-3, Burim-r ro 170beon-g Tel: +
m it may con ncern :
vice with FC C ID: PFRFX XRD-1717N NAW integrat tes a Wi-Fi m module :
Wi-Fi mo odule Brand Sparklan FCC ID RYK-WPEA A-121N dware design e the RF out r report(Rep ed to represe n changes ar tput power o port Numbe nt the compl re made on of the modu er : FR1316 liance of FCC the modules ules. pursuan 667-01AC /
C Part 15C/1 s, and the so nt to KDB 9
/ FR131667 15E conducte oftware has n 996369 D01 7-01AI / FR ed RF testing not been ch 1v01r04, the R131667-01A g items of th hanged to e original AN) are his device. diated RF te nally. esting items are tested on this hos st device, a and the test report is s submitted you have any y comments or questions
, please feel free to conta act me. To whom This dev No hard increase modular submitte The rad addition Should y Sincerel ly, Compan Type Na Title : A ny : Viework ame : Youjeo Assistant Man s Co., Ltd. ong Kim nager
1 2 | KDB INQUIRY LETTER | Cover Letter(s) | 87.55 KiB | April 30 2015 |
:
:
:
:
Link to Federal Communications Commission Home Page oetech@fccsun27w.fcc.gov 2014 12 23 11:39 jeff.do@kes.co.kr Response to Inquiry to FCC (Tracking Number 547865) FCC Home | Search | RSS | Updates | E-Filing | Initiatives | Consumers | Find People Office of Engineering and Technology Office of Engineering and Technology Inquiry on 12/23/2014 :
Inquiry:
With reference to a X-ray detecor, we have some questions. 1. The X-ray detector does not use the side & rear surface. So, we think that the X-ray detector has to need the fornt surface. please check it. 2. For head SAR, testing of both head and body properties should be conducted using a flat phantom. please check it. FCC response on 12/23/2014 XRaybuckystyledevicesdorequireSARanalysisconsistentwithKDBPublication447498D01(including simultaneoustransmissionconsiderations).Accordingly,SARtestingwillberequiredifthetestexclusion criteriaoutlinedinSection4.3arenotmet.Pleasebeawarethat,shouldtestingberequired,a0mmtest distanceshouldbeconsideredforsuchanEUT. Specifically:
1.KDB447498D01statesthatthetestseparationdistancewillbedeterminedbythesmallestdistance betweentheoutersurfaceofthedevicesandtheuser(4.1.5).Inthiscase,adistanceof0mmis expected.Insuchcases,SARtestingoftheEUTindirectcontactwithaflatphantomwouldbe appropriate. 1 Section4.3.1and4.3.2discussstandaloneandsimultaneoustestexclusionprocedureswhichmaybe applicabletothedifferenttransmittersontheEUT.Shouldtestexclusionbeapplied,astatementof justificationandcompliancemustbeincludedintheequipmentapproval,inlieuoftheSARreport,to qualifyfortheSARtestexclusionbeingclaim.AllanalysisshouldconsiderbothWiFiantennas. WithregardtoWiFispecifictestingconfigurations,KDBPublication248227D01discussesproper channelandsetupprocedures. 2.SARtestingalongthesideofthexraydetectorisnotrequiredsolongasthethereisnousecase requiringausertobewithin20cmoftheouteredgeoftheEUT. 3.Testingofbothheadandbodypropertiesshouldbeconductedusingaflatphantom.Theseparameters areoutlinedinKDBPublication865664D01. Attachment Details:
X-ray detector Do not reply to this message. Please select the Reply to an Inquiry Response link from the OET Inquiry System to add any additional information pertaining to this inquiry. 2
1 2 | PCB LAYOUT | Schematics | 1.00 MiB | April 30 2015 |
CAM350 V 10.1.0 : Wed Dec 10 14:53:00 2014 - (Untitled) : 01A-SILK-T.pho CAM350 V 10.1.0 : Wed Dec 10 14:53:00 2014 - (Untitled) : 04C-SILK-B.pho
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2015-04-30 | 5190 ~ 5230 | NII - Unlicensed National Information Infrastructure TX | Original Equipment |
2 | 5745 ~ 5825 | DTS - Digital Transmission System |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 | Effective |
2015-04-30
|
||||
1 2 | Applicant's complete, legal business name |
Vieworks Co., Ltd.
|
||||
1 2 | FCC Registration Number (FRN) |
0021983614
|
||||
1 2 | Physical Address |
41-3, Burim-ro170beon-gil, Dongan-gu
|
||||
1 2 |
Anyang-si, N/A
|
|||||
1 2 |
South Korea
|
|||||
app s | TCB Information | |||||
1 2 | TCB Application Email Address |
t******@timcoengr.com
|
||||
1 2 |
T******@TIMCOENGR.COM
|
|||||
1 2 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 2 | Grantee Code |
PFR
|
||||
1 2 | Equipment Product Code |
FXRD-1717NAW
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 | Name |
J****** K****
|
||||
1 2 | Title |
Assistant Manager
|
||||
1 2 | Telephone Number |
+82-7********
|
||||
1 2 | Fax Number |
+82-3********
|
||||
1 2 |
t******@vieworks.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 2 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 | Equipment Class | NII - Unlicensed National Information Infrastructure TX | ||||
1 2 | DTS - Digital Transmission System | |||||
1 2 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Flat Panel Detector | ||||
1 2 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 | Modular Equipment Type | Does not apply | ||||
1 2 | Purpose / Application is for | Original Equipment | ||||
1 2 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | Yes | ||||
1 2 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | Yes | ||||
1 2 | Grant Comments | Power listed is conducted. SAR compliance for portable use conditions has been evaluated as described in this filing. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing. The highest reported SAR value is < 0.08W/kg. This device has a 20 MHz and 40 MHz bandwidth mode. | ||||
1 2 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 | Firm Name |
KES Co., Ltd
|
||||
1 2 | Name |
I****** R****
|
||||
1 2 | Telephone Number |
82-31********
|
||||
1 2 | Fax Number |
82-31********
|
||||
1 2 |
k******@kes.co.kr
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15E | 38 CC MO | 5180 | 5240 | 0.0211 | |||||||||||||||||||||||||||||||||||
1 | 2 | 15E | 38 CC MO | 5190 | 5230 | 0.0234 | |||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 15C | 38 CC MO | 2412 | 2462 | 0.177 | |||||||||||||||||||||||||||||||||||
2 | 2 | 15C | 38 CC MO | 5745 | 5825 | 0.306 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC