4. Two difference ways to program 3 different wiring situation by following:
a.) Program by Z-Wave Interface Controller _ Configuration:
Parameter Number 01, Size 01 Parameter Value: 01 - To Control Light with 1 Wall Switch & to Control Light With 2 Wall Switches. 02 - To Control Light with 1 Wall Switch That Has Light Indicator. (This is factory default) b.) Program by Program SW:
Press and hold Program SW 3 seconds, LED will flash one time for setting up the type of To Control Light With 1 Wall Switch & To Control Light With 2 Wall Switches. Release the Program SW, press and hold Program SW 3 seconds again then LED will flash 2 times for setting up the type of To Control Light with 1 Wall Switch That Has Light Indicator. 5. Reset to the factory default setting: Press and hold the Program SW before power on. LED shall start flashing. Operation Turn on or turn off the appliance that attached to ZL7431 by Z-Wave Interface Controller, or manually turn on or off the light switch. Federal Communications Commission Statement This equipment has follows with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interferene by one of the following measures:
Reorient or relocate the receiving antenna, Increase the separation between the equipment and receiver, Connect the equipment into and outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undersired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate this equipment. Limited Warranty Vision Guarantees that every In-Wall Switch module is free from physical defects in material and workmanship under normal use for one year from the date of purchase. If the product proves defective during this one-year warranty period, Vision will replace it free of charge. Vision does not issue any refunds. This warranty is extended to the original end user purchase only and is not transferable. This warranty does not apply to : (1) damage to units caused by accident, dropping or abuse in handling, or any negligent use; (2) units which have been subject to unauthorized repair, taken apart, or otherwise modified; (3) units not used in accordance with instruction; (4) damages exceeding the cost of the product; (5) transit damage, initial installation costs, removal cost, or reinstallation cost. For information on addional devices, plesae visit us at www.visionsecurity.com.tw 6B1Z-74003 1020717 ZL7431
-3-
V1 Installation & Operation Manual ZL 7431 IN ZL 7431 EU ZL 7431 RU ZL 7431 US ZL 7431 JP ZL 7431 BR In-Wall Switch, 1 Relay Introduction Thanks for choosing the Visions In-Wall Switch module of the home automation device. This module is a Z-Wave enabled device (interoperable, two-way RF mesh networking technology) and is fully compatible with any Z-Wave enabled network. Every mains powered Z-Wave enabled device acts as a signal repeater and multiple devices result in more possible transmission routes which helps eliminate RF dead-sports. Z-Wave enabled devices displaying the Z-Wave logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturers Z-Wave enabled networks. With special design, this module can fit into most of electronic box in the market. This module will send On/Off signal to the appliance that attached to this module by receiving Z-Wave signal from controller or user can manually turn on/off the appliance by wall switch. Product Description & Specification Specification:
Protocol: Z-Wave (ZM3102N) Frequency Range:
865.22MHz (ZL7431IN) 868.42MHz (ZL7431EU) 869.00MHz (ZL7431RU) 908.42MHz (ZL7431US) 920.00MHz (ZL7431JP) 921.42MHz (ZL7431BR) Package Content 1pc ZL 7431 In-Wall Switch, 1 Relay 1pc Installation & Operation Manual Operating Range: Up to 100 feet line of sight Operating Temp.: -15C~ 60C (5F~140F) Operating Voltage:100VAC~240VAC Resistive Load:
800W for 110VAC 1300W for 220VAC Z-Wave Command Class COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_CONFIGUARION COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_SWITCH_ALL COMMAND_CLASS_SWITCH_BINARY mapping COMMAND_CLASS_BASIC COMMAND_CLASS_VERSION Installation Notice: If you are installing the entire Z-Wave system for the first time, please refer to the installation guide of Z-Wave Interface Controller before installing ZL7431 In-Wall Switch Module. 1. Following the wiring diagram to install ZL7431 according to your varied requirements. Note: Place antenna toward the surface and away from metal to get better signal.
-1-
2. For Inclusion in (adding to) a network: Put the Z-Wave Interface Controller into inclusion mode, and following its instruction to add the ZL 7431 to your controller. To get in the inclusion mode, the distance between module and controller is suggested to be in one meter. Turn on and turn off the wall switch that connects with ZL 7431 module 4 times to be included (or press the Program SW 4 times within 2 seconds to be included), then LED shall stop flashing. For Exclusion from (removing from) a network: Put the Z-Wave Interface Controller into exclusion mode, and following its instruction to delete the ZL 7431 from your controller. Turn on and turn off the wall switch that connects with ZL 7431 module 4 times to be excluded (or press the Program SW 4 times within 2 seconds to be excluded), then LED shall start flashing. 3. Status of ON (Binary Switch Set 0xFF or wall switch ON) Status of OFF (Binary Switch Set 0x00 or wall switch OFF)