-Connect the equipment into and outlet on a circuit different from that to which the receiver This equipment has follows with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interferene by one of the following measures:
is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undersired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate this equipment. Vision Guarantees that every In-Wall Switch module is free from physical defects in material and workmanship under normal use for one year from the date of purchase. If the product proves defective during this one-year warranty period, Vision will replace it free of charge. Vision does not issue any refunds. This warranty is extended to the original end user purchase only and is not transferable. This warranty does not apply to : (1) damage to units caused by accident, dropping or abuse in handling, or any negligent use; (2) units which have been subject to unauthorized repair, taken apart, or otherwise modified; (3) units not used in accordance with instruction; (4) damages exceeding the cost of the product; (5) transit damage, initial installation costs, removal cost, or reinstallation cost. For information on addional devices, plesae visit us at www.visionsecurity.com.tw ZL 7435-5 V0 1031205 6B1Z-7400A Installation & Operation Manual ZL7435IN-5 ZL7435MY-5 ZL7435EU-5 ZL7435RU-5 ZL7435US-5 ZL7435US-5_WIRE ZL7435IL-5 ZL7435KR-5 ZL7435HK-5 ZL7435JP-5 ZL7435BR-5 In-Wall Switch, 2 Relays
(Screw Terminal type or Wire type) Introduction Thanks for choosing the Visions In-Wall Switch module of the home automation device. This module is a Z-Wave enabled device (interoperable, two-way RF mesh networking technology) and is fully compatible with any Z-Wave enabled network and its security framework. Every mains powered Z-
Wave enabled device acts as a signal repeater and multiple devices result in more possible transmission routes which helps eliminate RF dead-spots. Z-Wave enabled devices displaying the Z-Wave logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturers Z-Wave enabled networks. With special design, this module can fit into most of electronic box in the market. This module will send On/Off signal to the appliance that attached to this module by receiving Z-Wave signal from controller. It also can control two appliances independently. When the device is secure included into Z-
Wave network, above communication will be encrypted. Product Description and Specification Package Content 1pc ZL 7435-5 In-Wall Switch, 2 Relays (Screw Terminal) 1pc Installation & Operation Manual Specification:
Protocol: Z-Wave (ZM5101) Frequency Range:
865.22MHz (ZL7435IN-5) 868.10MHz (ZL7435MY-5) 868.42MHz (ZL7435EU-5) 869.00MHz (ZL7435RU-5) 908.42MHz,916.00MHz
(ZL7435US-5,ZL7435US-5_WIRE) 916.00MHz (ZL7435IL-5) 919~923MHz (ZL7435KR-5) 919.80MHz (ZL7435HK-5) 922~926MHz (ZL7435JP-5) 921.42MHz (ZL7435BR-5) Operating Range: Up to 100 feet line of sight Operating Temp.: -15C~ 60C (5F~140F) Operating Voltage: 100VAC~240VAC Resistive Load:
550W for 110VAC 1100W for 220VAC Z-Wave Command Classes:
COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2 COMMAND_CLASS_MULTI_CHANNEL_V2 COMMAND_CLASS_POWER_LEVEL COMMAND_CLASS_PROTECTION COMMAND_CLASS_SECURITY COMMAND_CLASS_SWITCH_ALL COMMAND_CLASS_SWITCH_BINARY COMMAND_CLASS_VERSION COMMAND_CLASS_ZWAVEPLUS_INFO Installation Notice: If you are installing the entire Z-Wave system for the first time, please refer to the installation guide of Z-Wave Interface Controller before installing ZL7435 In-Wall Switch Module.
-1-
1. 1. 2. 3. Following the wiring diagram to install ZL7435. Note: Place antenna toward the surface and away from metal to get better signal.
: OFF LED Status after Power On:
Not Included: FLASH Included For Inclusion in (adding to) a network: Put the Z-Wave Interface Controller into inclusion mode, and following its instruction to add the ZL 7435 to your controller. To get in the inclusion mode, the distance between module and controller is suggested to be in one meter. Press 3 times within 2 seconds or turn on the wall switch 3 times within 2 seconds (or press toggle switch 3 times) to be included. For Exclusion from (removing from) a network: Put the Z-Wave Interface Controller into exclusion mode, and following its instruction to delete the ZL 7435 from your controller. Press 3 times within 2 seconds or turn on the wall switch 3 times within 2 seconds (or press toggle switch 3 times) to be excluded. For Association: Use Association to set up the reporting node after triggering for group 1 of SW1 (switch 1). Put the Z-Wave TM Interface Controller into association, and following its instruction to associate the ZL7435-5 with other devices. Support one association group (5 nodes). For MultiChannel Association: Use MultiChannel Association to set up the group 2 of SW2
(switch 2) which will assign the groups nodes or nodes endpoint. For Button Mode Switching: Use Command Class Configurations CONFIGURATION_SET to change the button mode (switch or toggle) Parameter 1 Byte 1 Value 0 = Switch (Default) 1 = Toggle
-2-
4. 5. 6. 7. 8. For SW1s Protection: Use Command Class Protections PROTECTION_SET to protect SW1. Value 00 1 2 Protection Level Normal (Default) Press 4 Times On & Off To Switch On/Off Status Only accept Z-Wave Command; such as:
BASIC_SET, SWITCH_ALL_ON, SWITCH_BINARY_SET & SWITCH_ALL_OFF For SW2s Protection: Use Command Class Multichannels MULTI_CHANNEL-
CMD_ENCAP to Encapsulate Command Class Protections PROTECTION_SET. Value 0 1 2 Protection Level Normal (Default) Press 4 Times On & Off To Switch On / Off Status Only accept Z-Wave Command For SWITCH_ALL_ON: Use SWITCH_ALL_SET to control all on or all off Value 0xFF 0x00 0x01 0x02 Status Accept SWITCH_ALL_ON & SWITCH_ALL OFF (Default) No accept SWITCH_ALL_ON & SWITCH_ALL OFF Only accept SWITCH_ALL OFF Only accept SWITCH_ALL_ON For SW1s Control: Press SW1 to control 1st Relays On & Off. Status Value ON OFF Binary Switch Set (0xFF) Binary Switch Set (0x00) Basic Set On Switch All On Basic Set Off Switch All Off For relay 1 or 2: Please use Multi-Channel command class to control Factory Default Reset: Power off first, press Program Switch and power on till 10 seconds, ZL7435 will send the Device Reset Locally Notification command and reset to the factory default.
(Remark: This is to be used only in the case of primary controller being inoperable or otherwise unavailable.) 9. Support OTA Firmware update from controller. Please refer to your controller manual. We 10. Support AES Function. recommend to exclusive the device & include again before use the device.
-3 -
Operation 11. All the rest commands depend on Z-Wave standard. Turn on or turn off two individual appliances that attached to ZL7435 by Z-Wave Interface Controller
-4-