all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 3.03 MiB | March 25 2024 / March 26 2024 | |||
1 |
|
Internal Photos | Internal Photos | 3.42 MiB | March 25 2024 / March 26 2024 | |||
1 |
|
External Photos | External Photos | 2.25 MiB | March 25 2024 / March 26 2024 | |||
1 |
|
Label & Label Location | ID Label/Location Info | 284.15 KiB | March 25 2024 / March 26 2024 | |||
1 |
|
2.911 (d)(5)(i)(ii) Attestation Statement | Attestation Statements | 165.32 KiB | March 25 2024 / March 26 2024 | |||
1 |
|
Antenna Specification | Test Report | 298.35 KiB | March 25 2024 / March 26 2024 | |||
1 | Block Diagram | Block Diagram | March 25 2024 | confidential | ||||
1 | Circuit Description | Operational Description | March 25 2024 | confidential | ||||
1 |
|
FCC Agent Authorization Letter | Cover Letter(s) | 9.67 KiB | March 25 2024 / March 26 2024 | |||
1 |
|
FCC Long-term Confidential Request | Cover Letter(s) | 282.90 KiB | March 25 2024 / March 26 2024 | |||
1 |
|
Multiple Model Confirmation Letter | Cover Letter(s) | 209.76 KiB | March 25 2024 / March 26 2024 | |||
1 |
|
RF Exposure - FP | RF Exposure Info | 103.47 KiB | March 25 2024 / March 26 2024 | |||
1 |
|
RF Exposure - PP | RF Exposure Info | 104.15 KiB | March 25 2024 / March 26 2024 | |||
1 | Schematics | Schematics | March 25 2024 | confidential | ||||
1 |
|
Test Report - FP | Test Report | 1.58 MiB | March 25 2024 / March 26 2024 | |||
1 |
|
Test Report - PP | Test Report | 1.57 MiB | March 25 2024 / March 26 2024 | |||
1 |
|
Test Setup Photos - FP | Test Setup Photos | 566.51 KiB | March 25 2024 / March 26 2024 | |||
1 |
|
Test Setup Photos - PP | Test Setup Photos | 559.45 KiB | March 25 2024 / March 26 2024 | |||
1 |
|
US Agent Attestation Letter | Attestation Statements | 16.55 KiB | March 25 2024 / March 26 2024 |
1 | User Manual | Users Manual | 3.03 MiB | March 25 2024 / March 26 2024 |
Should use the wireless telephone at the ear opposite the pacemaker. WTRs evaluation did not identify any risk to bystanders with pacemakers from other persons using wireless telephones. Whats in the box Connect and charge the battery About cordless intercom system Connect and charge the main unit / sub unit The main unit and sub unit have their marks on the label at the back of the unit. Go to www.vtechphones.com (US) to register your product for enhanced warranty support and latest VTech product news. Go to phones.vtechcanada.com (CA) for latest VTech product news. Important safety instructions When using your intercom equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury, including the following:
1. Read and understand all instructions. 2. Follow all warnings and instructions marked on the product. 3. Unplug this product from the wall outlet before cleaning. Do not use liquid or aerosol cleaners. Use a damp cloth for cleaning. 4. CAUTION: Do not install the product at a height above 2 meters. 5. Do not use this product near water such as near a bath tub, wash bowl, kitchen sink, laundry tub or a swimming pool, nor in a wet basement or shower. 6. Do not place this product on an unstable table, shelf, stand or other unstable surfaces. 7. Avoid placing the product in places with extreme temperature, direct sunlight, or other electrical devices. Protect the product from moisture, dust, corrosive liquids and fumes. 8. Slots and openings in the back or bottom of the main unit and sub unit(s) are provided for ventilation. To protect them from overheating, these openings must not be blocked by placing the product on a soft surface such as a bed, sofa or rug. This product should never be placed near or over a radiator or heat register. This product should not be placed in any area where proper ventilation is not provided. 9. This product should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supply in your home or office, consult your dealer or local power company. 10. Do not allow anything to rest on the power cord. Do not install this product where the cord may be walked on. 11. Never push objects of any kind into this product through the slots in the main unit or sub unit(s) because they may touch dangerous voltage points or create a short circuit. Never spill liquid of any kind on the product. 12. To reduce the risk of electric shock, do not disassemble this product, but take it to an authorized service facility. Opening or removing parts of the main unit and sub unit(s) other than specified access doors may expose you to dangerous voltages or other Incorrect reassembling can cause electric shock when the product is subsequently used. 13. Do not overload wall outlets and risks. extension cords. 14. Unplug this product from the wall outlet and refer servicing to an authorized service facility under the following conditions:
When the power supply cord or plug is damaged or frayed. If liquid has been spilled onto the product. If the product has been exposed to rain or water. If the product does not operate normally by following the operating instructions. Adjust only those controls that are covered by the operation Improper adjustment of other controls may result in damage and often requires extensive work by an authorized technician to restore the product to normal operation. If the product has been dropped and the telephone base and/or handset has been damaged. If the product exhibits a distinct change in performance. instructions. 15. Avoid using the product during an electrical storm. There is a remote risk of electric shock from lightning. 16. The power adapter is intended to be correctly oriented in a vertical or floor mount position. The prongs are not designed to hold the plug in place if it is plugged into a ceiling, under-the-table or cabinet outlet. pluggable the socket-outlet shall be installed near the equipment and shall be easily accessible. equipment, 17. For 18. CAUTION: Use only the batteries indicated in this manual. There may be a risk of explosion if a wrong type of battery is used. Use only the supplied rechargeable batteries. Do not dispose of batteries in a fire. They may explode. Disposed of used batteries according to the instruction. Do not use the battery in following conditions:
High or low extreme temperature or storage during use, transportation. Replacement of a battery with an incorrect type that can defeat a safeguard. Disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery, that can result in an explosion. Leaving a battery in an extremely high temperature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas. A battery subjected to extremely low air pressure that can result in an explosion or the leakage of flammable liquid or gas. 19. Use only the adapter included with this product. Incorrect adapter polarity or voltage can seriously damage the product. 20. The applied nameplate is located at the bottom or near of the product. SAVE THESE INSTRUCTIONS Battery Use only the batteries provided or equivalent. Do not dispose of the batteries in a fire. Check with local waste management codes for special disposal instructions. Do not open or mutilate the batteries. Released electrolyte is corrosive and may cause burns or injury to the eyes or skin. The electrolyte may be toxic if swallowed. Exercise care in handling batteries in order not to create a short circuit with conductive materials. Charge the batteries provided with this product only in accordance with the instructions and limitations specified in this manual. Precautions for users of implanted cardiac pacemakers Cardiac pacemakers (applies only to digital cordless telephones):
Wireless Technology Research, LLC
(WTR), an independent research entity, led a multidisciplinary evaluation of the interference between portable wireless telephones and implanted cardiac pacemakers. Supported by the U.S. Food and Drug Administration, WTR recommends to physicians that:
Pacemaker patients Should keep wireless telephones at least six inches from the pacemaker. Should NOT place wireless telephones directly over the pacemaker, such as in a breast pocket, when it is turned ON. Privacy: The same features that make a intercom system convenient create some limitations. Intercom calls are transmitted between the main unit and the sub unit(s) by radio waves, so there is a possibility that the intercom call conversations could be intercepted by radio receiving equipment within range of the intercom system. For this reason, you should not think of intercom call conversations as being as private as those on corded telephones. Electrical power: The main unit of this intercom system must be connected to a working electrical outlet. The electrical outlet should not be controlled by a wall switch. Calls cannot be made from the sub unit if the main unit is unplugged, switched off or if the electrical power is interrupted. Potential TV interference: Some intercom systems operate at frequencies that may cause interference to televisions and VCRs. To minimize or prevent such interference, do not place the main unit of the intercom system near or on top of a TV or VCR. If interference is experienced, moving the intercom system farther away from the TV or VCR often reduces or eliminates the interference. Rechargeable batteries: Exercise care in handling batteries in order not to create a short circuit with conducting material such as rings, bracelets and keys. The battery or conductor may overheat and cause harm. Observe proper polarity between the battery and the battery charger. Nickel-metal hydride rechargeable batteries: Dispose of these batteries in a safe manner. Do not burn or puncture the battery. Like other batteries of this type, if burned or punctured, they could release caustic material which could cause injury. Main unit Wall mount bracket Users manual 1 set for ICS3111 2 sets for ICS3121 3 sets for ICS3131 4 sets for ICS3141 5 sets for ICS3151 6 sets for ICS3161 7 sets for ICS3171 Sub unit Wall mount bracket Improve signal strength Wall mount (optional)
(For the US only) www.vtechphones.com/recycle. Scan the QR code on the right or visit done with it Recycle this product when you are To avoid interference, place the main unit in a central location of the house and at least 3 feet
(1 meter) away from thick walls as well as other household appliances such as, TV, radio, microwave oven, Wi-Fi router, large mirror, metal furniture and fish tank. Raise the antenna 1 Align and insert the four studs of the wall mount bracket to the holes on the back of the main unit or sub unit. 2 Slide the wall mount bracket leftward to lock it in place. To release the wall mount bracket from the main unit or sub unit, slide the bracket rightward. Battery: 3.6V Ni-MH battery Sub unit: 5V DC @ 1.0A Main unit: 5V DC @ 1.0A Power requirement environmental conditions at the time of use. Actual operating range may vary according to Maximum power allowed by FCC and IC. range Nominal effective DECT channel: 5 Channels Sub unit: 1921.536-1928.448 MHz Main unit: 1921.536-1928.448 MHz Transmit frequency Crystal controlled PLL synthesizer Frequency control et)
> 1 m (3 fe f e e t
( 3
> 1 m
> 1 m (3 feet) TV 3 4 5 1 2 3 4 Initiate a group call among main unit 1 and sub unit 2 to 5. 15 14 Visual ringer Flashes when there is an intercom call. Speaker GROUP Light is on when on a group call. When on a group call, press to leave the group call. SET Set ringtone when the unit is not in use. Enable or disable auto answer. Register or deregister sub unit. 11 12 13 14 15 16 hrs 7 8 9 10 11 12 7 8 9 10 11 12 15 Overview Main unit / Sub unit 1 1 2 3 2 4 3 5 4 6 5 6 13 13 14 5 6 7 8 9 Battery charging indicator (CHARGE) On when the battery is charging. Flashes when the battery is low. Microphone Main unit 1 / Sub unit 2 - 8 When the unit is not in use, its designated unit number light is steady on. On a sub unit, its designated unit number light flashes when it is out of range with the main unit. Press a unit number (1 - 8) to initiate a one-to-one call to main unit 1 or one of the sub unit 2 to 8. When there is an intercom call, the light of the initiating unit (1 - 8) flashes. Press to answer the intercom call. Designated unit number light becomes steady on during an intercom call. Press to end the intercom call. Name cards 8 name cards for main unit 1 and sub unit 2 to 8. VOL - / VOL +
Press to increase or decrease the volume of the speaker or ringer. 10 MONITOR Press this key and followed by the unit number to initiate a one-to-one monitoring call to main unit 1 or one of the sub unit 2 to 8. Light flashes when receiving a monitoring call. Press to end the monitoring call. TALK Light is steady on when on an intercom call or group call. Press to answer or end an intercom call. Auto answer indicator (AUTO ANS) On when the unit is set to auto answer calls. USB Type-C charging port Power on/off switch Antenna Users manualICS3111ICS3121ICS3131ICS3141ICS3151ICS3161ICS3171DECT 6.0 Intercom SystemScan the QR code for support information(CA)(US)Specifications are subject to change without notice. 2024 VTech Communications, Inc. | 2024 VTech Technologies Canada Ltd.All rights reserved. 02/24. ICS31X1_UM_V1.0VTech Communications, Inc. and its suppliers assume no responsibility for any damage or loss resulting from the use of this users manual. VTech Communications, Inc. and its suppliers assume no responsibility for any loss or claims by third parties that may arise through the use of this product.Company: VTech Communications, Inc.Address: 9020 SW Washington Square Road - Ste 555 Tigard, OR 97223, United StatesPhone: 1 (800) 595-9511 in the U.S. or 1 (800) 267-7377 in CanadaDisclaimer and Limitation of LiabilityTechnical specifications Operate Make a one-to-one intercom call Press 1 to call the main unit or 2 to 8 to call one of the sub units 2 to 8.
- OR -
1. Press TALK. The light of the available unit numbers turns on. 2. Press 1 to call the main unit or 2 to 8 to call one of the sub units 2 to 8. If you press an unavailable unit number, the unit sounds a three-beep error tone. Answer an intercom call When receiving an intercom call, the unit rings and the initiating unit number (1 - 8) flashes. Press TALK to answer.
- OR -
Press the flashing unit number to answer. Make a group intercom call You can make a group intercom call among the main unit (1) and the first 4 sub units (2 - 5). 1. On the main unit or one of the first 4 sub units, press GROUP to initiate a group call. The GROUP light of all units involved turn on. The units ring once and then all involved units connect to the call. 2. All connected units can speak among each others and hear each others via the speaker. To leave the group call, press GROUP on an individual unit, and the other units on the group call will continue with the call. To end the whole group conversation, the initiating unit press GROUP. Make a one-to-one monitoring call You can make a one-to-one monitoring call between any two units. You can set any unit to be monitored by another unit. When on a monitoring call, the microphone of the monitoring unit will be muted. To set a unit to be monitored 1. On any unit, press MONITOR to set the unit to be monitored. The light of the available unit numbers will turn on. 2. Press to select one of the available unit number to be the monitoring unit. All other unit number lights will then turn off. The microphone of the monitoring unit will be muted and the monitored unit cannot hear the monitoring unit unless the monitoring unit press the key to talk. 3. When the monitoring call starts, press and hold TALK on the monitoring unit and you can speak to the monitored unit. Release TALK on the monitoring unit after speaking to mute the microphone again. To end the monitoring call, press MONITOR on either unit. Receive a monitoring call 1. A unit rings once when receiving a monitoring call request from the monitored unit, and the MONITOR light and the initiating (monitored) unit number light flash. 2. Both units then connect to the call, and the MONITOR lights and the number lights of both units become steady on. To end the monitoring call, press MONITOR. Adjust ringer volume When the unit is not in use, press VOL - / VOL + to adjust the ringer volume. Adjust speaker volume During a call, press VOL - / VOL + to adjust the speaker volume. Settings Ringer tone 1. When a unit is not in use, press SET and then press VOL +. 2. Press VOL - / VOL + to scroll through the 10 ringtones. 3. Press SET to save the setting. Auto answer You can set the unit to auto answer calls. When set, the unit plays the ringer once and then picks up the call automatically. Enable auto answer When a unit is not in use, press SET, TALK, and then VOL +. You then hear a confirmation tone and the AUTO ANS light turns on. Disable auto answer When a unit is not in use, press SET, TALK, and then VOL -. You then hear a confirmation tone and the AUTO ANS light turns off. You can add new sub units (ICS3101, purchased separately) to the main unit. You can register up to 7 sub units to a main unit. Need help?
For operations and guides to help you using your telephone, and for latest information and supports, go and check the online help topics and online FAQs. Use your smartphone or mobile device to access our online help. Go to https://help.vtechphones.com/ICS3111 (US);
or https://phones.vtechcanada.com/en/support/
general/manuals?model=ics3111 (CA); OR Scan the QR code on the right. Launch the camera app or QR code scanner app on your smartphone or tablet. Hold the devices camera up to the QR code and frame it. Tap the notification to trigger the redirection of the online help.
(CA) If the QR code is not clearly displayed, adjust your cameras focus by moving your device closer or further away until it is clear.
(US) You can also call our Customer Support at 1 (800) 595-9511 [in US] or 1 (800) 267-7377 [in Canada] for help. Register / deregister sub unit Register a sub unit 1. When the main unit is not in use, press and hold SET for 4 seconds. The light of the first unoccupied unit number flashes. 2. Power up the new sub unit. 3. Press SET on the sub unit to begin registration. The TALK light flashes while in registration mode. 4. When registration completes, you hear a confirmation tone on both the main unit and the sub unit. The newly registered unit number light on the main unit will turn on for 3 seconds. On the registered sub unit, its designated unit number light will always turn on. Deregister sub units You may need to deregister sub units if you have 7 registered sub unit and need to replace one of them, or if you wish to change the unit number of a sub unit. You must first deregister all sub units, and then register each unit, one at a time. 1. When the main unit is not in use, press and hold SET for 10 seconds. The lights of all registered unit numbers flash for 10 seconds. 2. Press SET again to confirm deregistration. You hear a confirmation tone. For C-UL compliance only Mesures de scurit importantes Afin de rduire les risques dincendie, de blessures corporelles ou dlectrocution, suivez toujours ces mesures prventives de base lorsque vous utilisez votre tlphone :
1. Lisez et comprenez bien toutes les instructions. 2. Observez toutes les instructions et mises en garde inscrites sur lappareil. 3. Dbranchez ce tlphone de la prise murale avant de le nettoyer. Nutilisez pas de nettoyeurs liquides ni en arosol. Nutilisez quun chiffon doux et lgrement humect. ATTENTION: Ne pas installer le socle tlphonique une hauteur suprieure 2 mtres. 4. 5. Nutilisez pas ce produit prs de leau, tel que prs dun bain, dun lavabo, dun vier de cuisine, dun bac de lavage ou dune piscine, ou dans un sous-sol humide ou sous la douche. 6. Ne dposez pas ce tlphone sur un chariot, support ou table chancelants. Lappareil pourrait tomber et tre srieusement endommag. 7. vitez dinstaller le systme tlphonique dans les endroits soumis une temprature extrme, la lumire directe du soleil ou proximit immdiate dautres appareils lectriques ou lectroniques. Protgez votre tlphone contre les sources dhumidit, la poussire, les vapeurs et les liquides corrosifs. 8. Le botier de lappareil est dot de fentes et douvertures daration situes larrire ou en dessous. Afin dempcher la surchauffe, ces ouvertures ne doivent pas tre obstrues en plaant lappareil sur un lit, divan, tapis ou autre surface similaires. Ne placez pas cet appareil proximit dun lment de chauffage ni dune plinthe lectrique. De plus, ne linstallez pas dans une unit murale ou un cabinet ferm qui ne possde pas daration adquate. 9. Ne faites fonctionner cet appareil quavec le type dalimentation indiqu sur les tiquettes de lappareil. Si vous ne connaissez pas le voltage de votre maison, consultez votre marchand ou votre fournisseur dlectricit. 10. Ne dposez rien sur le cordon dalimentation. Installez cet appareil dans un endroit scuritaire, l o personne ne pourra trbucher sur la ligne dalimentation ni le cordon tlphonique modulaire. 11. Ninsrez jamais dobjets travers les fentes et ouvertures de cet appareil, car ils pourraient toucher des points de tension dangereux ou court-circuiter des pices, ce qui constituerait un risque dincendie ou dlectrocution. Nchappez pas de liquides dans lappareil. 12. Afin de rduire les risques dlectrocution, ne dmontez pas lappareil, mais apportez-le plutt un centre de service qualifi sil doit tre rpar. En enlevant le couvercle, vous vous exposez des tensions dangereuses ou autres dangers similaires. Un remontage inadquat peut tre lorigine dune lectrocution lors dune utilisation ultrieure de lappareil. Dbranchez lappareil avant de procder au nettoyage. Utilisez un chiffon humide et doux. 13. Ne surchargez pas les prises de courant et les rallonges. 14. Dbranchez cet appareil de la prise de courant et communiquez avec le dpartement de service la clientle de VTech dans les cas suivants :
Lorsque le cordon dalimentation est endommag ou corch. Si du liquide a t chapp dans lappareil. Si lappareil a t expos une source dhumidit telle que la pluie ou leau. Si le produit ne fonctionne pas normalement en respectant les instructions de fonctionnement. Rglez uniquement les instructions de fonctionnement. Les rglages incorrects des autres commandes pourraient provoquer un dommage qui pourrait exiger un travail exhaustif de la part dun technicien autoris afin de rtablir le fonctionnement normal de lappareil. Si le produit a t chapp et que le socle et/ou le combin a t endommag. Si le produit affiche une nette diminution de sa performance. les commandes indiques dans le 15. vitez dutiliser un tlphone (autre quun sans fil) pendant un orage. Les clairs peuvent tre lorigine dune lectrocution. 16. Ces adaptateurs ont t conus pour tre orients en position verticale ou monts au sol. Les broches ne sont pas conues pour maintenir ladaptateur en place si celui-ci est barnch dans une prise au plafond ou sous une table/ armoire. 17. Pour le MATERIEL RACCORDE PAR PRISE DE COURANT, le socle de prise de courant doit etre installe a proximite du materiel et doit etre aisement accessible. 18. MISE EN GARDE: Il peut y avoir un risque dexplosion si vous utilisez le mauvais type de piles pour le tlphone. Nincinrez pas les piles. Celles-ci risqueraient dexploser. Mettre au rebut les batteries usages conformment aux instructions du fabricant. Dbrancher les lignes tlphoniques avant le remplacement des piles. vite dutiliser la batterie dans les conditions suivantes:
des tempratures extrmes faibles ou leves auxquelles une batterie peut tre soumise pendant lutilisation, le stockage ou le transport. remplacement dune batterie par un type incorrect pouvant supprimer une protection. mise au rebut dune batterie dans un feu ou dans un four chaud, ou crasement mcanique ou coupure dune batterie, susceptible de provoquer une explosion. maintien dune batterie dans un environnement trs haute temprature pouvant provoquer une explosion ou la fuite de liquide ou de gaz inflammables. batterie soumise une pression de lair extrmement faible pouvant provoquer une explosion ou la fuite de liquide ou de gaz inflammables. 19. Nutilisez que les adaptateurs inclus avec ce produit. Lutilisation dun adaptateur dont la polarit ou la tension serait inadquate risque dendommager srieusement le produit et mettre votre scurit en pril. 20. La plaque signaltique applique est situe au bas ou proximit du produit. CONSERVEZ CES INSTRUCTIONS Pile Nutilisez que la pile incluse ou lquivalent. Ne jetez pas la pile au feu. Vrifiez les instructions spcifiques de mise aux rebus auprs des autorits locales. Nouvrez pas et ne mutilez pas la pile. Llectrolyte qui sen chapperait est corrosif et pourrait causer des brlures ou des blessures aux yeux ou la peau. Llectrolyte est toxique si aval. Soyez prudents lorsque vous manipulez les piles afin dviter les courts-circuits provoqus par des matriaux conducteurs. Rechargez la pile incluse avec cet appareil, selon les instructions et limites spcifies dans ce guide dutilisation. Stimulateurs cardiaques implants dans lorganisme Les simulateurs cardiaques (sapplique uniquement aux tlphones numriques sans fil) :
Lorganisme Wireless Technology Research, LLC (WTR), une firme de recherche indpendante, a men une valuation pluridisciplinaire des interfrences entre les tlphones sans fil portatifs et les stimulateurs cardiaques implants dans lorganisme. Appuye par lAdministration des aliments et drogues (FDA) des tats-Unis, la firme WTR recommande aux mdecins :
Avis aux dtenteurs de stimulateurs cardiaques Ils doivent tenir le tlphone sans fil une distance dau moins six pouces du stimulateur cardiaque. Ils ne doivent PAS placer le tlphone sans fil directement sur le stimulateur cardiaque, tel que dans une poche de chemise, lorsque celui-ci est en marche. Ils doivent utiliser le tlphone sans fil en lappuyant sur loreille qui se trouve dans la direction oppose au stimulateur cardiaque. Ltude effectue par lorganisme WRS na pas identifi de risque pour les dtenteurs de simulateurs cardiaques causs par les gens qui utilisent un tlphone sans fil proximit de ceux-ci. propos des tlphones sans fil Confidentialit : Les mmes caractristiques qui constituent des avantages pour les tlphones sans fil affichent galement des restrictions. Les appels tlphoniques sont transmis entre le combin sans fil et le socle par le biais dondes radio ; il y a donc la possibilit que vos conversations tlphoniques sans fil soient interceptes par des quipements de rception radio se trouvant dans la porte du combin sans fil. Pour cette raison, vous ne devez pas percevoir les communications tlphoniques sans fil comme tant aussi confidentielles que celles des tlphones cordons. Alimentation lectrique : Le socle de ce tlphone sans fil doit tre branch une prise lectrique fonctionnelle. La prise lectrique ne doit pas tre contrle par un interrupteur mural. Les appels ne pourront pas tre effectus du combin sans fil si le socle est dbranch ou mis hors tension ou si le courant est coup. Possibilit dinterfrences aux tlviseurs : Certains tlphones sans fil fonctionnent sur des frquences pouvant causer des interfrences aux tlviseurs et aux magntoscopes. Pour rduire ou prvenir de telles interfrences, ne placez pas le socle du tlphone sans fil prs ou sur un tlviseur ou magntoscope. Sil y a prsence de parasites, il est conseill dloigner le tlphone sans fil du tlviseur ou du magntoscope afin de rduire possiblement les interfrences. Piles rechargeables : Manipulez les piles avec soin afin de ne pas les court-circuiter avec des bagues, bracelets ou cls. Les piles ou le conducteur peut surchauffer et causer des blessures. Respectez la polarit adquate entre la pile et le chargeur. Les bloc-piles rechargeables lhydrure mtallique de nickel : Jetez ces blocs-piles de manire cologique et scuritaire. Ne les incinrez pas et ne les percez pas. Tel que les autres piles de ce type, elles pourraient dgager une matire toxique qui peut causer des blessures corporelles si elles sont brles ou perces. The RBRC seal The RBRC seal on the nickel-metal hydride battery indicates that VTech Communications, Inc. is voluntarily participating in an industry program to collect and recycle these batteries at the end of their useful lives, when taken out of service within the United States and Canada. The program provides a convenient alternative to placing used nickel-
metal hydride batteries into the trash or municipal waste, which may be illegal in your area. VTechs participation makes it easy for you to drop off the spent battery at local retailers participating in the program or at authorized VTech product service centers. Please call 1 (800) 8 BATTERY for information on Ni-MH battery recycling and disposal bans/
restrictions in your area. VTechs involvement in this program is part of its commitment to protecting our environment and conserving natural resources. The RBRC seal and 1 (800) 8 BATTERY are registered trademarks of Call2recycle, Inc. FCC, ACTA and IC regulations FCC Part 15 NOTE: This equipment has been tested and found to comply with the requirements for a Class B digital device under Part 15 of the Federal Communications Commission (FCC) rules. These requirements are intended to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Connect the equipment into an outlet on a circuit different from that to which the Increase the separation between the equipment and receiver. receiver is connected. Consult the dealer or an experienced radio/TV technician for help. WARNING: Changes or modifications to this equipment not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Privacy of communications may not be ensured when using this telephone. This equipment complies with FCC/ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the equipment and your body. This Class B digital apparatus complies with Canadian requirement:
CAN ICES-3 (B)/NMB-3(B). FCC Part 68 and ACTA This equipment complies with Part 68 of the FCC rules and with technical requirements adopted by the Administrative Council for Terminal Attachments (ACTA). The label on the back or bottom of this equipment contains, among other things, a product identifier in the format US:AAAEQ##TXXXX. This identifier must be provided to your telephone service provider upon request. The plug and jack used to connect this equipment to premises wiring and the telephone network must comply with applicable Part 68 rules and technical requirements adopted by ACTA. A compliant telephone cord and modular plug is provided with this product. It is designed to be connected to a compatible modular jack that is also compliant. An RJ11 jack should normally be used for connecting to a single line and an RJ14 jack for two lines. See the installation instructions in the users manual. The Ringer Equivalence Number (REN) is used to determine how many devices you may connect to your telephone line and still have them ring when you are called. The REN for this product is encoded as the 6th and 7th characters following the US: in the product identifier (e.g., if ## is 03, the REN is 0.3). In most, but not all areas, the sum of all RENs should be five (5.0) or less. For more information, please contact your telephone service provider. This equipment must not be used with Party Lines. If you have specially wired alarm dialing equipment connected to your telephone line, ensure the connection of this equipment does not disable your alarm equipment. If you have questions about what will disable alarm equipment, consult your telephone service provider or a qualified installer. If this equipment is malfunctioning, it must be unplugged from the modular jack until the problem has been corrected. Replacement to this telephone equipment can only be made by the manufacturer or its authorized agents. For replacement procedures, follow the instructions outlined under the Limited warranty. If this equipment is causing harm to the telephone network, the telephone service provider may temporarily discontinue your telephone service. The telephone service provider is required to notify you before interrupting service. If advance notice is not practical, you will be notified as soon as possible. You will be given the opportunity to correct the problem and the telephone service provider is required to inform you of your right to file a complaint with the FCC. Your telephone service provider may make changes in its facilities, equipment, operation, or procedures that could affect the proper functioning of this product. The telephone service provider is required to notify you if such changes are planned. If this product is equipped with a corded or cordless handset, it is hearing aid compatible. If this product has memory dialing locations, you may choose to store emergency telephone numbers (e.g., police, fire, medical) in these locations. If you do store or test emergency numbers, please:
Remain on the line and briefly explain the reason for the call before hanging up. Perform such activities in off-peak hours, such as early morning or late evening. Industry Canada This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canadas licence-exempt RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired operation of the device. Privacy of communications may not be ensured when using this telephone. The term IC: before the certification/registration number only signifies that the Industry Canada technical specifications were met. The Ringer Equivalence Number (REN) for this terminal equipment is 0.1. The REN indicates the maximum number of devices allowed to be connected to a telephone interface. The termination of an interface may consist of any combination of devices subject only to the requirement that the sum of the RENs of all the devices not exceed five. This product meets the applicable Innovation, Science and Economic Development Canada technical specifications. California energy commission battery charging testing instructions This intercom system is set up to comply with the energy-conserving standards right out of the box. These instructions are intended for California Energy Commission (CEC) compliance testing only. When the CEC battery charging testing mode is activated, all functions, except battery charging, will be disabled. To activate the CEC battery charging testing mode:
1. Unplug the main unit power adapter from the power outlet. Make sure all sub units are plugged with charged batteries before proceeding. 2. While you press and hold SET, plug the main unit power adapter back to the power outlet. 3. After about 10 seconds, the lights of all registered unit numbers flash for 10 seconds. Then, press SET again. You hear a confirmation tone. If the intercom system fails to enter this mode, the main unit will be powered up as normal. Repeat all the steps mentioned above. To deactivate the CEC battery charging testing mode:
1. Unplug the main unit power adapter from the power outlet, and then plug it back in. Then the main unit is powered up as normal. 2. Register each sub units to the main unit. See Register a sub unit section. Limited Warranty What does this limited warranty cover?
The manufacturer of this VTech Product warrants to the holder of a valid proof of purchase
(Consumer or you) that the Product and all accessories provided in the sales package
(Product) are free from defects in material and workmanship, pursuant to the following terms and conditions, when installed and used normally and in accordance with the Product operating instructions. This limited warranty extends only to the Consumer for Products purchased and used in the United States of America and Canada. What will VTech do if the Product is not free from defects in materials and workmanship during the limited warranty period (Materially Defective Product)?
During the limited warranty period, VTechs authorized service representative will replace at VTechs option, without charge, a Materially Defective Product. If we replace the Product, we may use new or refurbished replacement parts. If we choose to replace the Product, we may replace it with a new or refurbished Product of the same or similar design. We will retain defective parts, modules, or equipment. Replacement of the Product, at VTechs option, is your exclusive remedy. VTech will return the replacement Products to you in working condition. You should expect the replacement to take approximately 30 days. How long is the limited warranty period?
The limited warranty period for the Product extends for ONE (1) YEAR from the date of purchase. If VTech replaces a Materially Defective Product under the terms of this limited warranty, this limited warranty also applies to the replacement Product for a period of either (a) 90 days from the date the replacement Product is shipped to you or (b) the time remaining on the original one-year warranty; whichever is longer. What is not covered by this limited warranty?
This limited warranty does not cover:
1. Product that has been subjected to misuse, accident, shipping or other physical damage, improper installation, abnormal operation or handling, neglect, inundation, fire, water or other liquid intrusion. Product that has been subjected to contact with liquid, water, rain, extreme humidity or heavy perspiration, sand, dirt or the like; but then only to the extent the damage was not caused by incorrectly securing the waterproof handsets protective elements, for example, failing to properly close a seal), or such protective elements are damaged or missing (e.g. a cracked battery door), or subjecting a Product to conditions beyond its stated specifications or limits (e.g. 30 minutes in 1 meter of fresh water). Product that has been damaged due to repair, alteration or modification by anyone other than an authorized service representative of VTech;
Product to the extent that the problem experienced is caused by signal conditions, network reliability, or cable or antenna systems;
Product to the extent that the problem is caused by use with non-VTech accessories;
Product whose warranty/quality stickers, product serial number plates or electronic serial numbers have been removed, altered or rendered illegible;
Product purchased, used, serviced, or shipped for repair from outside the United States of America or Canada, or used for commercial or institutional purposes
(including but not limited to Products used for rental purposes);
Product returned without a valid proof of purchase (see item 2 below); or Charges for installation or set up, adjustment of customer controls, and installation or repair of systems outside the unit. 2. 3. 4. 5. 6. 7. 8. 9. 2. How do you get warranty service?
To obtain warranty service in the United States of America, please visit our website at www.vtechphones.com or call 1 (800) 595-9511. In Canada, go to phones.vtechcanada.com or dial 1 (800) 267-7377. NOTE: Before calling for service, please review the users manual - a check of the Products controls and features may save you a service call. Except as provided by applicable law, you assume the risk of loss or damage during transit and transportation and are responsible for delivery or handling charges incurred in the transport of the Product(s) to the service location. VTech will return replaced Product under this limited warranty. Transportation, delivery or handling charges are prepaid. VTech assumes no risk for damage or loss of the Product in transit. If the Product failure is not covered by this limited warranty, or proof of purchase does not meet the terms of this limited warranty, VTech will notify you and will request that you authorize the cost of replacement prior to any further replacement activity. You must pay for the cost of replacement and return shipping costs for the replacement of Products that are not covered by this limited warranty. What must you return with the Product to get warranty service?
1. Return the entire original package and contents including the Product to the VTech service location along with a description of the malfunction or difficulty; and Include a valid proof of purchase (sales receipt) identifying the Product purchased
(Product model) and the date of purchase or receipt; and Provide your name, complete and correct mailing address, and telephone number. 3. Other limitations This warranty is the complete and exclusive agreement between you and VTech. It supersedes all other written or oral communications related to this Product. VTech provides no other warranties for this Product. The warranty exclusively describes all of VTechs responsibilities regarding the Product. There are no other express warranties. No one is authorized to make modifications to this limited warranty and you should not rely on any such modification. State/Provincial Law Rights: This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state or province to province. Limitations: Implied warranties, including those of fitness for a particular purpose and merchantability (an unwritten warranty that the Product is fit for ordinary use) are limited to one year from the date of purchase. Some states/provinces do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. In no event shall VTech be liable for any indirect, special, incidental, consequential, or similar damages
(including, but not limited to lost profits or revenue, inability to use the Product or other associated equipment, the cost of substitute equipment, and claims by third parties) resulting from the use of this Product. Some states/provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Please retain your original sales receipt as proof of purchase
1 | Label & Label Location | ID Label/Location Info | 284.15 KiB | March 25 2024 / March 26 2024 |
ICS3121 ENGRAVING FILE(Feb 23,2024) 5V 1A THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
1)THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND 2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. PRIVACY OF COMMUNICATIONS MAY NOT BE ENSURED WHEN USING THIS PHONE. FCC ID : EW780-3080-00 IC:1135B-80308000 HVIN:35-201978IC VTECH TELECOMMUNICATIONS LTD. MANUFACTURED IN CHINA Accessory INTERCOM SYSTEM VTech Customer Service 1-800-595-9511 www.vtechphones.com Model:ICS3121 Main S/N: XXXXXXXXXXXXXXXXXXXX Model:ICS3171 Main Model:ICS3141 Main Model:ICS3121 Main Model:ICS3121 Sub Model:ICS3111 Sub S/N: XXXXXXXXXXXXXXXXXXXX S/N: XXXXXXXXXXXXXXXXXXXX S/N: XXXXXXXXXXXXXXXXXXXX S/N: XXXXXXXXXXXXXXXXXXXX S/N: XXXXXXXXXXXXXXXXXXXX Model:ICS3151 Main Model:ICS3111 Main Model:ICS3101 Sub Model:ICS3131 Sub S/N: XXXXXXXXXXXXXXXXXXXX S/N: XXXXXXXXXXXXXXXXXXXX Model:ICS3161 Main Model:ICS3131 Main S/N: XXXXXXXXXXXXXXXXXXXX S/N: XXXXXXXXXXXXXXXXXXXX LABEL S/N: XXXXXXXXXXXXXXXXXXXX S/N: XXXXXXXXXXXXXXXXXXXX Model:ICS3141 Sub Model:ICS3151 Sub S/N: XXXXXXXXXXXXXXXXXXXX S/N: XXXXXXXXXXXXXXXXXXXX Model:ICS3161 Sub Model:ICS3171 Sub S/N: XXXXXXXXXXXXXXXXXXXX S/N: XXXXXXXXXXXXXXXXXXXX
1 | 2.911 (d)(5)(i)(ii) Attestation Statement | Attestation Statements | 165.32 KiB | March 25 2024 / March 26 2024 |
VTech Telecommunications Ltd Add: 23/F Tai Ping Ind Center Block 1 57 Ting Kok Rd Tai Po NT, Hong Kong Telephone: (852)2680 5398 Fax:(852)2680 5252 E-mail: Michael_Tsui@vtech.com ATTESTATION STATEMENT Date: 2024-02-20 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements Part 2.911(d)(5)(i), (ii) Filing FCC ID: EW780-3080-00 VTech Telecommunications Ltd certifies that the equipment for which authorization is sought is not covered equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. VTech Telecommunications Ltd certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing covered equipment. Sincerely, Signature Michael Tsui Approbation Supervisor
1 | FCC Agent Authorization Letter | Cover Letter(s) | 9.67 KiB | March 25 2024 / March 26 2024 |
VTech Telecommunications Ltd Add: 23/F Tai Ping Ind Center Block 1 57 Ting Kok Rd Tai Po NT, Hong Kong Telephone: (852)2680 5398 Fax: (852)2680 5252 E-mail: Michael_Tsui@vtech.com FCC Authorization Date: 2024-02-20 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern:
We, VTech Telecommunications Ltd, the undersigned, Hereby authorizes China Certification ICT Co., Ltd (Dongguan) to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by China Certification ICT Co., Ltd (Dongguan) on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. This authorization is valid until further written notice from the applicant. Sincerely Yours, Signature Michael Tsui Approbation Supervisor QA-FR-170-B
1 | FCC Long-term Confidential Request | Cover Letter(s) | 282.90 KiB | March 25 2024 / March 26 2024 |
VTech Telecommunications Ltd Add: 23/F Tai Ping Ind Center Block 1 57 Ting Kok Rd Tai Po NT, Hong Kong Telephone: (852)2680 5398 Fax: (852)2680 5252 E-mail: Michael_Tsui@vtech.com FCC Confidential Authorization Date: 2024-02-20 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request regarding application for certification of FCC ID: EW780-3080-00 In accordance with Sections 0.457 and 0.459 of the Commissions Rules, VTech Telecommunications Ltd hereby requests long-term confidential treatment of information accompanying this application as outlined below:
Block Diagram Schematics Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely Yours, Signature Michael Tsui Approbation Supervisor
1 | Multiple Model Confirmation Letter | Cover Letter(s) | 209.76 KiB | March 25 2024 / March 26 2024 |
VTech Telecommunications Ltd Jan. 10, 2024 To whom it may concern, FCC-Multiple Models Confirmation Letter I, the undersigned, hereby confirm that the family models are listed in the following table. These models are identical as follows:
Electrical designs, including software & firmware PCB layout Others, please specify Construction design/Physical design/Enclosure The only differences between these models are the follows for marketing purpose:
Color Trade name Others, please specify Package type, no. of the subunit and Charger. Cosmetic details Model number The differences between main unit and sub unit as below:
Flash IC size is different:
main unit flash IC: 64M sub unit flash IC: 16M main unit: with Eeprom IC(64K bits) sub unit does not have Eeprom IC. Suffix ( a,b,c in ICS31ab-c and ICS310b-c) represents Color code Others, please specify
,but models with suffix (
Packing configuration a= any alphanumeric character is presenting number of the sub unit;
b= any alphanumeric character is presenting the different package type or color of the enclosure;
c= any alphanumeric character or blank is presenting the no. of the accessory sub unit or bundling unit. a, b, c
) are identical in:
Electrical designs, including software & firmware PCB layout Construction design/Physical design/Enclosure Others, please specify For the product subject to authorization under FCC Declaration of Conformity:
In addition, it is to confirm that all the below information 1) The U.S. responsible party, 2) FCC label artworks and location, 3) FCC required statement in the user manual Are the same but different in the following model numbers only:
Item # New Model Model Number Trade Name 1 2 YES YES ICS3111 ICS3121 VTech VTech Remarks 1 main unit +1 sub unit 1 main unit +2 sub unit VTech Telecommunications Ltd YES YES YES YES YES YES YES YES 3 4 5 6 7 8 9 10 ICS3131 ICS3141 ICS3151 ICS3161 ICS3171 ICS31ab-c ICS3101 ICS310b-c VTech VTech VTech VTech VTech VTech VTech VTech 1 main unit + 3 sub unit 1 main unit +4 sub unit 1 main unit +5 sub unit 1 main unit +6 sub unit 1 main unit +7 sub unit 1 main unit + a sub unit 1 accessory sub unit 1 accessory sub unit ICS3121 main unit(BS) and sub unit(HS) are same except for differences as below:
flash IC size is different:
main unit flash IC: 64M sub unit flash IC: 16M main unit: with Eeprom IC(64K bits) sub unit does not have Eeprom IC. SW is different The sample(s) being submitted to China Certification ICT Co., Ltd (Dongguan) for conformity assessment is ICS3121 of the above list. All above models FCC ID is EW780-3080-00 Regards, Michael Tsui Approbation Supervisor
1 | US Agent Attestation Letter | Attestation Statements | 16.55 KiB | March 25 2024 / March 26 2024 |
U.S. AGENT LETTER OF ATTESTATION Date: 2023-03-20 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Ref: Attestation Statements CFR 47 2.911(d)(7) Filing VTech Telecommunications Ltd certifies that, as of the date of the filing of the application, VTech Communications, Inc. is our designated U.S. agent for service of process for the FCC ID. VTech Telecommunications Ltd accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-
related proceeding involving the equipment. VTech Communications, Inc. accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the FCC ID. Designated U.S. Agent Information:
Company Name: VTech Communications, Inc. Address: 9020 SW Washington Square Road, Tigard OR 97223 Agent FRN : 0033411265 Tel.: +1(503) 596-1212 Email: cconrad@vtechphones.com Signed by: Chris Conrad Signature:
Applicant Company Name: VTech Telecommunications Ltd Address: 23/F Tai Ping Ind Center Block 1 57 Ting Kok Rd Tai Po NT, Hong Kong Applicant FRN: 0015973951 Tel: (852)2680 5398 Email: Michael_Tsui@vtech.com Signed by: Michael Tsui Signature:
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2024-03-26 | 1921.536 ~ 1928.448 | PUB - Part 15 Unlicensed PCS Base Station | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2024-03-26
|
||||
1 | Applicant's complete, legal business name |
VTech Telecommunications Ltd
|
||||
1 | FCC Registration Number (FRN) |
0015973951
|
||||
1 | Physical Address |
23/F Tai Ping Ind Center Block 1
|
||||
1 |
Tai Po NT, N/A
|
|||||
1 |
Hong Kong
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
b******@baclcorp.com
|
||||
1 | TCB Scope |
A3: Unlicensed Personal Communication System (PCS) devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
EW7
|
||||
1 | Equipment Product Code |
80-3080-00
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
M****** T****
|
||||
1 | Title |
Approbation Supervisor
|
||||
1 | Telephone Number |
852-2********
|
||||
1 | Fax Number |
852-2********
|
||||
1 |
m******@vtech.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | PUB - Part 15 Unlicensed PCS Base Station | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Intercom System | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
CHINA CERTIFICATION ICT CO., LTD (DONGGUAN)
|
||||
1 | Name |
T****** O****
|
||||
1 | Telephone Number |
0086 ********
|
||||
1 |
q******@ccttt.com.cn
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15D | 1921.53600000 | 1928.44800000 | 0.1090000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC