all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 2 |
|
User Manual | Users Manual | 1.30 MiB | September 11 2001 | |||
1 2 | Block Diagram | |||||||
1 2 | Cover Letter(s) | |||||||
1 2 | External Photos | |||||||
1 2 | Internal Photos | |||||||
1 2 | ID Label/Location Info | |||||||
1 2 | Test Report | |||||||
1 2 | Test Setup Photos | |||||||
1 2 | External Photos | September 11 2001 | ||||||
1 2 | ID Label/Location Info | September 11 2001 | ||||||
1 2 | Internal Photos | September 11 2001 |
1 2 | User Manual | Users Manual | 1.30 MiB | September 11 2001 |
WebEye B101 Manual Ver 1.0 WebEye B101 Users Guide
* This manual is for WebEye B101 firmware version 1.2.0. If you have later version of firmware, please download the last updated users guide from WebGates homepage
(www.webgateinc.com) System Requirements nn For WebEye Network: 10 Base-T LAN
(Leased line, xDSL, Cable Modem, ISDN) or PSTN nn For a PC to access WebEye Processor: Pentium II and above RAM: 64MB and More OS: Windows 98/ME/NT/2000 Screen Resolution: 1024 X 768 pixels and above Network: 10 Base-T LAN or PSTN WebGate Inc. FCC Compliance Statement Caution : Any changes or modifications in construction of this device which are not expressly approved the party responsible for compliance could void the user's authority to operate the equipment. NOTE : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications, However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help. 2 WebEye WebEye B101B101 Users Guide Important Notice 1. WebEye B101 is not weatherproof. Therefore you should be well aware of environmental specifications that are included in the manual. In case of outdoor use, where it needs additional weather criteria, you should equip weatherproof case to protect WebEye B101 from water, moisture, or temperature (higher or lower than specification). For WebEye cleaning, g ently wipe with clean dry cloth. 2. Be sure to use a 12V DC or 24V AC adaptor to supply power to WebEye B101. Connecting WebEye B101 to an adaptor other than 12V DC or 24V AC, may cause electric damage to WebEye B101. 3. Be caution in handling WebEye B101 for physical shocks may harm the product. 4. WebEye B101 is made of aluminum. Therefore you can hurt human beings if you throw it to them or hit on them. When installing WebEye B101 , be sure it is attached tight and stable to avoid any human injures. Be cautious to locate on safe places where children are unreachable. 5. If WebEye B101 does not operate properly, please contact the closest local WebGate distributor for after sales service. In all cases, you are prohibited to disassemble the product. If so, WebGate is not responsible for any malfunction nor service warranty. 6. Camera surveillance laws may differ for each country. Therefore, please contact the local region first to avoid any surveillance law violations and to apply for authorized purposes only. 3 WebEye WebEye B101B101 Users Guide CONTENTS I. Introduction ..................................................................................................................................................................... 6 II. Product Description ..................................................................................................................................................... 7 1. Contents........................................................................................................................................................................7 2. WebEye B101 view and description........................................................................................................................7 1) Front view and description..............................................................................................................................7 2) Rear view and description............................................................................................................................... 8 3) LED of Ethernet port ........................................................................................................................................8 4) Descriptions on DIP Switches ........................................................................................................................9 III. WebEye Installation Summary, Connection & Placing.................................................................................... 9 1. Installation Summary ..................................................................................................................................................9 2. Connecting.................................................................................................................................................................... 9 IV. Installing WebEye Setup Program.......................................................................................................................... 9 V. Assigning IP Address and Configuring Administrators Condition. ........................................................... 10 1. Connecting WebEye to a PC ................................................................................................................................... 10 1) Connecting WebEye on Internet or LAN.................................................................................................... 10 2) Connecting WebEye to a PC......................................................................................................................... 10 2. Assigning IP address and Configuring administrators condition with Setup program................................ 10 1) Starting Setup Program for WebEye............................................................................................................ 10 2) Configuring Administrators Conditions.................................................................................................... 11 3. Assigning IP Address with ARP command .......................................................................................................... 11 1) Using ARP in Windows 98 and NT............................................................................................................. 11 2) Using ARP in Windows 95 ........................................................................................................................... 11 3) Verifying Installation ...................................................................................................................................... 12 VI. Accessing WebEye Homepage & Monitoring Real -time Image ................................................................... 12 1. Starting Web browser................................................................................................................................................ 12 2. Login page.................................................................................................................................................................. 12 1) ID and password.............................................................................................................................................. 12 2) Behind Firewall............................................................................................................................................... 13 3) WebEye Plug-in for Netscape user.............................................................................................................. 13 4) WebEye Active-X for MS Explorer User................................................................................................... 13 5) FAQ ................................................................................................................................................................... 13 3. Real time monitoring through Default Viewer ..................................................................................................... 14 1) Image control................................................................................................................................................... 14 2) Integrated PTZ mechanism control.............................................................................................................. 15 3) Convenient pop-up menu............................................................................................................................... 15 4) Administrators page access.......................................................................................................................... 16 5) Program download .......................................................................................................................................... 16 6) About................................................................................................................................................................. 16 4. Real time monitoring through Server Push Viewer............................................................................................. 17 1) Image Control.................................................................................................................................................. 17 2) PTZ mechanism control................................................................................................................................. 17 4 WebEye WebEye B101B101 Users Guide 3) Pop-up Menu.................................................................................................................................................... 18 4) To Home ........................................................................................................................................................... 18 5) Capture.............................................................................................................................................................. 18 6) Admin ............................................................................................................................................................... 18 7) Plug-in ............................................................................................................................................................... 18 8) FAQ ................................................................................................................................................................... 18 VII. Configuring Administrators Condition at Admin page ........................................................................... 18 1. Administrator Login.................................................................................................................................................. 18 1) Accessing through setup program................................................................................................................ 18 2) Accessing through Web browser.................................................................................................................. 19 2. Configuring Administrators Condition at Homepage........................................................................................ 19 1) System Configuration..................................................................................................................................... 19 2) User Configuration ......................................................................................................................................... 19 3) Network Configuration.................................................................................................................................. 20 4) Dynamic IP registration service for ISDN and xDSL users .................................................................... 21 5) How to find registered WebEye in WebEye Internet homepage............................................................. 22 6) Security Configuration................................................................................................................................... 22 7) Video Configuration....................................................................................................................................... 23 8) Application Configuration............................................................................................................................. 24 9) Pan/Tilt/Zoom Configuration........................................................................................................................ 25 10) Serial Port Configuration............................................................................................................................. 26 11) Digital I/O Configuration............................................................................................................................ 26 12) Alarm Configuration .................................................................................................................................... 27 13) User Custom Configuration........................................................................................................................ 27 Appendix Detailed Specifications of WebEye B101.................................................................................................................... 29 1. General........................................................................................................................................................................ 29 2. Network....................................................................................................................................................................... 29 3. Mechanical................................................................................................................................................................. 30 4. Environmental............................................................................................................................................................ 30 5. Compatible external devices and software ............................................................................................................ 30 5 WebEye WebEye B101B101 Users Guide I. Introduction What is WebEye B101?
The WebEye B101 is a network dome camera server solution with an integrated Internet server, image compression device, flash memory, and many other features. No other hardware is necessary for use. The WebEye relay video source from a dome camera to network and provides real time images over networks and the Internet. Simply provide power and connect LAN cable and video cable to the WebEye. WebEye utilizes Wavelet image compression and Linux operating system. Wavelet and Linux enable WebEye to transfer high quality images faster and with a greater degree of reliability than standard JPEG systems. Features and Benefits Ease of Use WebEye requires either Netscape Navigator 4.7 (or higher) or Microsoft Internet Explorer 5.0
(or higher) for use. Windows 2000 is recommended for best results. Connect WebEye to the Internet and it is ready for use. Compatible with most Systems and Protocols WebEye supports TCP/IP networking, SMTP, HTTP and other Internet-related protocols. In addition, the WebEye can be used in mixed operating system environments, such as Windows, UNIX, Macintosh and OS/2. WebEye also integrates easily into other Internet/Intranet applications and CGI scripts. Simple Administration - WebEye can be configured and managed directly from its own web page. Moreover, as new upgrades become available, it is easy to upgrade all WebEye camera products remotely over the network. Wavelet Image Format - Unlike many other products that need to fracture image files prior to broadcast, the WebEye delivers complete, highly compressed pictures in Wavelet format. Wavelet has image compression rates 30-300% higher than standard JPEG. By utilizing Wavelet, image file sizes are much smaller than conventional camera servers and Wavelet's image quality is superior to other camera servers as well. Wavelet can transmit up to 123 frames per second. External Device Connection - External devices such as IR-sensors, switches and external video input can be connected to WebEye via the auxiliary Input/Output port. Users Programmable Space WebEye contains 4.5MB of configurable Flash Memory for user-programmable and user-configurable space. Because WebEye also acts as a server, this space can be used to create a personal web page. Embedded Linux Operating System WebEye uses an embedded Linux operating system within its 32bit RISC CPU. Linux is based on UNIX and is one of the most stable operating systems available. There is very litt le chance of the operating system crashing. 6 WebEye WebEye B101B101 Users Guide II. Product Description 1. Contents Unpack and check all the items as below. Item WebEye B101 Manual Crossover Cable Direct Cable DB-9 Connector and wire Screw & anchor CD ROM title Description Network server for dome camera WebEye User's Guide Quick reference guide 1 meter crossover cable 2 meter direct cable DB-9 connector wired with 2meter communication cable to connect with an external Modem 4 sets of screws and plastic anchors Setup program and manual Remarks Provided on CD Printed material Red-colored White-colored 2. WebEye B101 view and description 1) Front view and description Connector Name Description Remark Digital Inputs To input digital signal. There are 4 pairs of digital inputs. Ethernet DC 12V AC 24V To connect 10 Base-T Ethernet cable. Article 3) To connect a power supply unit of 12V DC. To connect a power supply unit of 24V AC. 7 WebEye WebEye B101B101 Users Guide 2) Rear view and description Connector Name Description DIP switch Video Input Video Output RS-232 RS-232 RS-422 RS-485 To designate video signal termination of Video Input BNC connector. (Only the left switch is used) To input video signal through a coaxial cable. To output video signal through a coaxial cable.
(Roof-through from Video Input BNC connector) To communicate between WebEye and external devices such a dome camera, WebEye A10 (An audio transmission kit), or an external modem. These pins are for devices that satisfy RS-232C protocol, and they are consisted in RX1, TX1, and GND. To communicate between WebEye and external devices such a dome camera, WebEye A10 (An audio transmission kit), or an external modem. These pins are for devices that satisfy RS-232C protocol, and they are consisted in RX2, TX2, and GND. To communicate between WebEye and a dome camera that satisfies RS-422 protocol. They are half-duflex. It is consisted in R+, R-, T+, and T-. To communicate between WebEye and a dome camera that satisfies RS-485 protocol. They are consisted in 485+ and 485-. Short R+ and R- with a wire to get RS422+ and short T+ and T - to get RS422-. Remark Article 4) GND pin is co-used. 3) LED of Ethernet port Yellow LED: This LED indicates the status of data transmission. After power is supplied, it is on for the first 4-5 seconds and then it goes off. And it blinks continuously when a user access WebEye and WebEye transmits data. 8 WebEye WebEye B101B101 Users Guide Green LED : This LED indicates the status of networking. After power is supplied, it is on for the first 1-2 seconds, and then it blinks once at every one second as long as the network is connected. 4) Descriptions on DIP Switches This is to designate video signal termination. If you want to monitor real time image through a CCTV monitor as well as WebEye, you may connect a dome camera to Video Input connector and a CCTV monitor to Video Output connector. In this case, you should decide which one is terminal of video signal. WebEye is not affected if a CCTV monitor is designated as terminal. If you connect a dome camera to Video Input and monitor real time video only through a PC, place the first DIP switch (marked with No. 1) at upper position ON. If you monitor real time video through a CCTV monitor as well as a PC, connect a dome camera to Video Input and a monitor to Video Output. And place the first DIP switch (marked with No. 1) at lower position OFF. If the CCTV monitor has a DIP switch and it is configurable the termination, you may change the termination from the CCTV monitor to WebEye such as the DIP switch in WebEye ON and the DIP switch in a CCTV monitor OFF. However a CCTV monitor is generally set as termination of the video signal. III. WebEye Installation Summary, Connection & Placing 1. Installation Summary Connect Ethernet and Power to WebEye on local network for configuration Install a setup program of WebEye to a PC on local network Assign an IP address to WebEye and configure administrators condition Configure users condition Place WebEye for your purpose, and re -connect power and Ethernet Adjust the Focus 2. Connecting Connect Ethernet line to the Ethernet port in the rear. Connect the power supply to a power supply port in the rear. Confirm that the LED of the Ethernet port blinks 3. Placing Place WebEye appropriately for your purpose IV. Installing WebEye Setup Program Copy WebEyeSetup.exe file from the enclosed CD (or Diskette). Paste the file into your PC Click the file on your PC to activate Setup program. 9 WebEye WebEye B101B101 Users Guide V. Assigning IP Address and Configuring Administrators Condition. 1. Connecting WebEye to a PC 1) Connecting WebEye on Internet or LAN. You may use direct cable (white colored one) to connect WebEye on Internet or LAN. Though you connect WebEye as follows, a remote user may not access WebEye before you configure its network setting properly. 2) Connecting WebEye to a PC. You may use crossover cable (red colored one) to directly connect WebEye to a PC. This connection is just to configure WebEye. 2. Assigning IP address and Configuring administrators condition with Setup program 1) Starting Setup Program for WebEye Click the WebEyeSetup.exe file on your PC. When the Setup Program is executed, the setup program detects and shows every WebEye connected on the local network. From the WebEyes listed, select one to assign a new IP address. (Default is 211.53.133.92). To choose a WebEye, click on its MAC Address or IP addres The Reboot button will reboot the WebEye. This process takes 10-20 seconds. 10 WebEye WebEye B101B101 Users Guide 2) Configuring Administrators Conditions To access the WebEyes Administrators Page from the Setup Menu, enter the admin.s password and click the Start Configuration button. To configure several WebEyes simultaneously , follow the Steps below. However, some information such as Date and Time at System, Serial Number, and IP Configuration at Network, will not change. Date and Time at System and IP Configuration at Network can be changed in the Setup program. TheSerial Numbernever changes. After configuring all of the conditions, close WebEye homepage. Click Save button. Save the information to a directory. Select another WebEye on the local network and type in the administrators password. Click Start Configuration and Load buttons in turns. A Loading Completed message will appear on the window when the procedure is completed. 3. Assigning IP Address with ARP command 1) Using ARP in Windows 98 and NT When using WebEye with Windows 98 and Windows NT, follow the steps below. Open a DOS window and type the following commands. arp -s <WebEye IP address> <WebEye Ethernet address>
ping -t <WebEye IP address>
Example arp -s 192.168.1.3 00-40-8c-10-00-86 ping -t 192.168.1.3 2) Using ARP in Windows 95 When using WebEye with Windows 95, follow the s teps below. Open a DOS window and type the following commands. arp -s <WebEye IP add.> <WebEye Ethernet add.> <my PC IP add.>
ping <WebEye IP address>
Example arp -s 192.168.1.3 00-40-8c-10-00-86 192.168.1.2 ping 192.168.1.3 11 WebEye WebEye B101B101 Users Guide 3) Verifying Installation After successfully completing the above procedures, the following message (or similar) will appear on the screen:
Request timed out
Request timed out Reply from 200.243.232.178: bytes=32 time=2ms TTL=255 Reply from 200.243.232.178: bytes=32 time=2ms TTL=255 Ping statistics for 200.243.232.178:
Packets: Sent = 4, Received = 4, Lost = 0 (0% loss), Approximate round trip times in milliseconds:
Minimum = 1ms, Maximum = 2ms, Average = 1ms If the above ping reply does not appear, press 'F3' and ' Enter' keys. Normally Request timed out messages appear 7 times before reply ing properly. Once the above ping reply appears press <Ctrl>+<C> keys to make it stop. When the ping reply stops, data loss may range from 0% to 99%. This is normal. If the statistic shows 100% loss, check the following criterions: (a) network line and connection status are stable; (b) IP address assigned to WebEye is available; (c) PC and WebEye have the same local network IP address. Same local IP address of C grade network means that first 3 sets of numbers are the same but the fourth set is different. For example 192.168.1.2 and 192.168.1.3 are in the same local network. (If there is a Network Mask on the network, this can be a n exception. For detailed information on IP, refer to appendix 3) VI. Accessing WebEye Homepage & Monitoring Real-time Image After assigning WebEye an IP address, you may access WebEye B101 and monitor real-time image on Internet. However you may not access its Homepage on remote network until assigning other addressees like gateway address, subnet mask, broadcast address properly. 1. Starting Web browser Start your web browser and enter your WebEye IP address. Then you can see a build-in homepage of WebEye. WebEye supports up to 100 users simultaneously. If a person tries to access WebEye as the 101st user, one cannot receive any image but will see a message of user counter on upper right side of homepage as Connected Client#: 100 2. Login page 1) ID and password To verify registered WebEye users, there is a Login page. If you are to connect to WebEye, you should follow login procedures. 12 WebEye WebEye B101B101 Users Guide If you key in users ID and password, you may access to a viewer to monitor real-time images. With administrators ID and password, you may also access to a real-time image viewer with administrators authority. The default value of both users ID and password are guest, and administrator may change it at Admin page. But, each ID and password must be composed within 9 bytes. (e.g. 9 English letters) 2) Behind Firewall If your PC is connected on a network where firewall is. In the case, you may not view real time image properly because video TCP port of WebEye is blocked. Common video TCP port (A default video TCP port of WebEye is 8080th port.) is blocked under firewall. If you are under firewa ll, you may view real time image through WebEyes Server Push Viewer that transmits video through Web TCP port instead of video TCP port. By clicking on Behind Firewall menu, you may directly connect Server Push Viewer when you access WebEye homepage. 3) WebEye Plug-in for Netscape user To monitor real-time image through Netscape Navigator, user should install WebEye Plug-in program first by clicking WebEye Plug-in menu. When you connect WebEye for the first time or you have Plug-in program of lower version, you have to download it clicking Download WebEye Plug In Now! button. Then you click Grant and Install buttons respectively. 4) WebEye Active -X for MS Explorer User For a M icrosoft Explorer User, Active-X Control program is required. The program will be installed automatically when a user accesses to WebEye. For Active-X installation on your PC, just click Yes to the question if you want to install the program on pop-up window. If you cannot see images after installation, you should check if Active-X Control program (a file named Web Camera Server Control) is installed or not. You may check Web Camera Server Control fold of C:\Windows \Download Program Files. If the Web Camera Server Control file is not installed at all in the directory, try it again to download and install it. If the file is already installed but image is not seen, remove the file and re-install it.
(Active-X Control program) file the in 5) FAQ A lot of questions and answers are provided here for troubleshooting. If user has another question that is not answered here, please contact WebGate through its Internet homepage. 13 WebEye WebEye B101B101 Users Guide 3. Real time monitoring through Default Viewer At default viewer, a user may configure image transmission method and control integrated PTZ mechanism of a dome camera. The PTZ control panel is activated in some seconds depending on network speed. On the left side panel, there are menus for changing real time image viewer, accessing administration page, downloading Plug-in program and viewing information on version and Q&A. 720x486 Viewer: By selecting this viewer, a user monitor images of 720 by 486 resolutions. This viewer has the identically same functions of default viewer but the image panel is bigger by 4 times than that of default viewer. Server Push Viewer: If WebEye B101 or users PC is behind firewall on network, a user may monitor real time image through Server Push Viewer. Some functions such as Progressive Mode image transmission, Image Quality control, and Quality Box creation menus out of image control and Preset, Auto Focus , and Focus Sensitivity control out of PTZ control are not supported in this viewer. 1) Image control There are five menus for controlling image transmission method. These menus are not to be activated non-PC platform such as Macintosh and Unix system.
(1) Gray Mode If you choose this mode, the images are displayed in black and white. And, you can view the images transmitted faster than in color image. By click again the button, the function is released.
(2) Progressive Mode In the case of Progressive Mode on, every image is regenerated from low to high resolution. In other words, 14 WebEye WebEye B101B101 Users Guide an image is reproduced from vague to clear for user to see what is happening and later one may detect exact things. This function is useful when you use a low speed network, because it reduces waiting time.
(3) Single Shot Mode When this button is clicked, one frame of image is reproduced. Therefore, it is stopped transmitting further image. To resume transmitting real-time i mages, click the button again.
(4) Resolution You may select a level of resolution among 3 levels (360x243, 180x121, 90x60). High-resolution image is big, and its transmission speed is slow. You may monitor 720x486 resolution images through 720x486 Viewe r.
(5) Frame rate You may choose image transmission speed. If you choose Fastest, you can get images at the fastest speed under your network environment. 2) Integrated PTZ mechanism control This is to control integrated PTZ mechanism of a dome camera. The control panel is deactivated at first. And it is to be activated when a user click on Take Control button.
(1) Take Control / Give Control This is to get power of controlling PTZ mechanism of the connected dome camera. A user who is permitted to control PTZ mechanism may get the power by clicking Take Control button. When the user gets the power, the button is toggled into Give Control. During the assigned time, a user may abandon the control power.
(2) Pan/Tilt In the center of the control panel, there is a plotted space with 4 arrows of up, down, left and right directions. This is to control pan and tilt mechanism of a dome camera with the mouse. By placing the mouse cursor on the panel and clicking the left button of a mouse at a certain point of the panel, a dome camera pans and tilts.
(3) Zoom (W/T) You may zoom in (W: Wide) and zoom out (T: Tele).
(4) Auto Focus Basically, a dome camera has auto-focus function and it focuses an object automatically. A new object in the view, however, may not be focused. In the case Auto Focus button is used to send commands to focus automatically to all objects that appear in the view newly.
(5) Manual Focus (N/F) You may control zoom mechanism with near (N) and far (F) buttons. This is to optim ize images focus. Focusing sensitivity is set with Focus Sensitivity in pop-up menu as well as in administration page. 3) Convenient pop-up menu A small window of 5 menus appears when you click the right button of the mouse. However only a certain users who are permitted can utilize the functions such as Image Info, Quality Box, Focus Sensitivity, and Image Quality. And the results of the four functions are to be affected in every image that is transmitted to all users. Save File As menu is permitted to any user. 15 WebEye WebEye B101B101 Users Guide
(1) Image Info You may decide the color (black or white) of the information that is shown on the left top of the image. And you may leave out the information. A user who has Video control right may utilize this menu.
(2) Quality Box This is to set a certain area clear and remained area dull. You can overcome insufficient network bandwidth with this function, because the file size is reduced with unfocused area. Quality Box is to be set like under written description. Choose New QBOX button. Place mouse cursor on a certain point of real time image where to start QBOX. Click and drag the mouse point. You can also re-use previous QBOX area to focus again by clicking Enable QBOX. Disable QBOX is to finish. The image activated Focusing Area function is seen in the right. The image quality of outer area of QBOX is to be set with Ambient Level menu. The level is from 1 to 5. If you select Level 1, the quality is similar to focused area. And if you select Level 5, the unfocused area is shown dark.
(3) Focus sensitivity You may configure movement degree of zoom mechanism. The sensitivity is from Level 0 to Level 9. By selecting Level 9, user zooms in or out at the largest degree. A user who has PTZ control right may utilize this menu.
(4) Image quality It is to set image quality. The image quality is from Level 0 to 9. If user chooses the Level 9, WebEye sends the finest image. However, transmission frame rate will be reduced because of large sized data. If user chooses Level 0, WebEye sends dullest image but fast. A user who has Video control right may utilize this menu.
(5) Save File As It is to save a frame of still image as an electric file. A still image can be saved as bitmap (*.bmp) file or Wavelet format file (*.eye). Wavelet formatted image file is to be reproduced on Internet browsers such as Netscape Navigator or Internet Explorer as long as the PC is installed Active-X or Plug-in program. 4) Administrators page access Clicking Goto Administrators Page menu, you go to a login page of administration page. However only the user who has authority as an administrator can access the page with administrators ID and password. 5) Program download As WebEye compresses image with Wavelet algorithm, user needs to install Plug-in program to see transmitted image through Netscape Navigator on ones PC. Clicking Netscape Plugin menu, a user accesses a page where to download Plug-in program. 6) About User may look up information on software versions clicking Version and on trouble shooting clicking FAQ regarding to installation or running WebEye. 16 WebEye WebEye B101B101 Users Guide 4. Real time monitoring through Server Push Viewer If WebEye is installed on a network where firewall is, you may access WebEye through server-push viewer to monitor real-time images. 1) Image Control Progressive Mode image transmission menu is not supported.
(1) Resolution You may select a resolution level among five. (90x60, 180x121, 360x243, 720x243, 720x486)
(2) Frame Rate You may choose image transmission speed. (1fps, 3fps, 5fps, 10fps, fastest)
(3) Play Control If you choose this mode, the images are displayed in black and white. And, you can view the images transmitted faster than in color image. By click again the button, the function is released.
(4) Single Shot Mode When this button is clicked, one frame of image is reproduced. Therefore, it is stopped transmitting further image. To resume transmitting real-time images, click the button again. 2) PTZ mechanism control Preset and Auto Focus are not supported.
(1) Pan and Tilt If you click the buttons, you can move the direction of WebEye to where you want to see.
(2) Zoom You may zoom in and zoom out.
(3) Focus You may control manually to optimize the images focus. 17 WebEye WebEye B101B101 Users Guide
(4) Acceleration Rate You may choose moving speed of Pan/Tilt/Zoom mechanism among three steps of fast, normal and slow. 3) Pop-up Menu Image Quality control, Quality Box creation, and Focus Sensitivity control are not supported.
(1) Image Info You may decide the color (black or white) of the information that is shown on the left top of the image. And you may leave out the information. A user who has Video control right may utilize this menu.
(2) Save File As It is to save a frame of still image as an electric file. A still image can be saved as bitmap (*.bmp) file or Wavelet format file (*.eye). Wavelet formatted image file is to be reproduced on Internet browsers such as Netscape Navigator or Internet Explorer as long as the PC is installed Active-X or Plug-in program. 4) To Home This is to go to main viewer. The main viewer is set in administrators page. 5) Capture This is to capture image and save as a file. This menu is the same function as Save File As menu. 6) Admin Clicking Admin menu, you go to a login page of administration page. However only the user who has authority as an administrator can access the page with administrators ID and password. 7) Plug-in As WebEye compresses image with Wavelet algorithm, user needs to install Plug-in program to see transmitted image through Netscape Navigator on ones PC. Clicking Netscape Plugin menu, a user accesses a page where to download Plug-in program. 8) FAQ User may look up information on trouble shooting clicking FAQ regarding to installation or running WebEye. VII. Configuring Administrators Condition at Admin page This page is for administrator. Administrator may control operating status remotely. This page can be accessed through Setup program by clicking Start Configuration button. 1. Administrator Login 1) Accessing through setup program First you click on MAC address or IP address of WebEye to select a certain one. Then you key in the administrators ID and password (Default ID and password are admin ), and click Start Configuration button in turns. When you click Start Configuration button, the setup program automatically connects you to Admin page of WebEye Homepage. 18 WebEye WebEye B101B101 Users Guide 2) Accessing through Web browser On Web browser, a user may access WebEye login page with its IP address. In the login page, a user may key in administrators ID and password or a normal users ID and password. With any of ID and password, the user may access real time image viewer page. 2. Configuring Administrators Condition at Homepage 1) System Configuration version software This page is to set name, date & time, location, and description of ones WebEye. Model, serial number and appear automatically.
(1) WebEye Name The name is to be used to register the WebEye on a certain server, if you use dynamic IP address.
(2) Model By clicking Detailed H/W Information, you may view detailed hardware information such as maximum numbers of channel, serial port, digital input, digital output, etc. The model name is marked automatically.
(3) Installation Location & Additional Description The information is shown in the real time image viewer page as well as in a dynamic IP registration list.
(4) Date & Time There are three date & time menus. In WebEye Current Date & Time panel, the date and time, which is set in WebEye, appears. In System (PC) Current Date & Time panel, the same date and time as is set in users PC appears.
(5) Administrators E-mail Address In this panel, administrator records ones e-mail address. If administrator put a contact menu of e -mail communication on real time image viewer page, the linked e-mail address to the contact menu is to be synchronized with this. So administrator can keep up e-mail address easily.
(6) Initialize Flash Info Administrator initializes almost all the information saved on flash memory. However Date & Time , Model, Serial Number, IP configuration, passwords, and all items in Video menu are not initialized.
(7) Rebooting If WebEye has any problem, administrator can reboot it without adjusting power supply. This button works as on/off switch. 2) User Configuration This page is to configure IDs and passwords of an administrator and 5 users.
(1) User Account 19 WebEye WebEye B101B101 Users Guide There are one administrators account and 5 users accounts. Account name can be changed.
(2) Password If you want to open your WebEye to everyone, you may not change default users ID and password. However you should change administrators ID and password with unique ones of yours.
(3) Access Rights Administrator may give or forfeit users right of PTZ control and video control. With default setting, administrator has both right of PTZ control and video control and normal user doesnt have any right. 3) Network Configuration This page is to define network type and set network addresses of WebEye. activates the xDSL administrator
(1) DHCP Client Protocol If DHCP Client Protocol menu, all the addresses are going to set automatically by WebEye detecting them from DHCP server of your ISP. The detected addresses are not seen on the screen.
(2) Select Network Interface If WebEye is connected on xDSL line that needs PPPoE process, administrator should select xDSL (PPPoE). However line doesnt need PPPoE process, administrator should select Ethernet though WebEye is connected on xDSL line.
(3) Ethernet Interface Administrator may configure IP address, subnet mask, broadcast address, gateway address, and DNS addresses of WebEye. For broadcast address, administrator may set it automatically by clicking Get From Netmask button after assigning IP address and subnet mask. MTU Size: Depending on network type, administrator may set data packet size with this menu to utilize the network at most effectively. DNS Server IP Address: This is used when you register your WebEye B101 on dynamic IP registration list of WRS (WebEye Registration Server). WRS has its domain name of webeye.to and the domain name is registered on DNS servers on the world.
(4) xDSL Interface If WebEye is connected on xDSL line and needs PPPoE process, administrator should select xDSL (PPPoE) and configure ID and password for PPPoE. ID and password may be acquired from the ISP that installed the line. And WebEye may get IP address when it is connected on xDSL line. 20 WebEye WebEye B101B101 Users Guide 4) Dynamic IP registration service for ISDN and xDSL users IP registration server This page is to register WebEye on dynamic IP registration server. If WebEye is installed on a network of dynamic IP address (floating IP address), administrator should register the WebEye to dynamic to give simple connectivity to common users. To solve the problem WebGate run a server making a list of WebEyes that have dynamic IP addresses. On the server, WebEye registers its information such as name, location, and description, so that common users may detect a certain WebEye. Name, location and description are assigned at System Configuration page. If administrator does not change them, the WebEye will register default information on the list, and it will be very difficult to point out and access a certain WebEye. The list is on an Internet homepage of WebEye, www.webeye.to.
(1) Auto IP Registration Function Administrator may register ones WebEye by enabling Auto IP Registration Function. Registration process is that WebEye detects IP addresses from DHCP server and informs the detected IP addresses to dynamic IP registration server. And the server updates already registered information with new one. Please keep in mind that user have to enable DHCP Client Protocol at Network Configuration page to have WebEye get dynamic IP addresses automatically, when WebEye is installed on a network of dynamic IP address.
(2) Registration Server Address This is to configure a server address for registration. The registration server to be used for Dynamic IP registration should be installed proper S/W, developed by WebGate Inc. If you do not run a server for IP registration, keep the servers name as default figure (webeye.to).
(3) Registration Interval Dynamic IP address is commonly used on xDSL, ISDN or Cable Modem lines. To maintain continuous connectivity, user should reset the Registration Interval shorter than the default value. Because an IP is to be changed from time to time, some user may not access by clicking on a WebEye if actual information on WebEye is changed from the registered IP information on the dynamic IP registration server.
(4) Add Public List There are two registration systems. One is to register on a public list and another is on a private list. Please refer to Article 3) Public List : This list is open to anyone who accesses WebEye Internet homepage
(www.webeye.to). Private List: This list is not seen to anyone. Even the owner of a WebEye can get the information on ones WebEye only without viewing information on others WebEye.
(5) Access Token Access token is a password and it is used when you register your own WebEye on a list Users WebEye out of all WebEyes on WRS(WebEye Registration Server.) 21 WebEye WebEye B101B101 Users Guide 5) How to find registered WebEye in WebEye Internet homepage On WebEye Internet homepage (www.webeye.to), there are menus to find WebEye that is registered on WRS
(WebEye Registration Server).
(1) Sign up membership To search your WebEye out of a public list or a private list, you have to sign up membership first. You may sign up on the server through Membership menu.
(2) Finding WebEye from public list To access WebEye that is registered on public list, you may find it through Service or Demo menus. Once click Service or Demo menu, you may find WRS (WebEye Registration Service) WebEye list on WRS page that is a main page of the Service menu. The sub-menu WRS is on the left side.
(3) Finding WebEye from private list To access WebEye that is registered on private list, you should make your own WebEye list before. You may make the list through Users WebEye menu. In the list, there are to be registered any WebEye from the Public List or Private List. On Users WebEye page, there two sub-menus, Your WebEye List and Search and Append. My WebEye List: You may maintain your own WebEye registering it on this list. When you login this homepage, WRS (WebEye Registration Server) detects and shows all the WebEyes that you listed appear on your own list. Search and Appe nd: This menu is to append a certain WebEye on your own list. You may append WebEye on your own list as follows. 6) Security Configuration This page is to control accessibility to ones WebEye with IP addresses.
(1) IP/Subnet Filtering Mode If this function is on, only the user whose PCs IP address is registered on WebEye can access the WebEye. Administrator may temporarily disallow a registered user to access to WebEye with a menu on the right side of each IP address. Any IP addresses are to be listed. If IP/Subnet Filtering Mode, anyone may access ones WebEye through a Web browser with any PC.
(2) Image Encryption Mode Administrator may restrict people to receive images from ones WebEye, even though people accessed it. If Image Encryption Mode is enabled and a pin number is assigned, people have to key in the assigned pin number to see image after accessing WebEye image viewers. Security Configuration is a double-checking function to control accessibility, utilizing User Account Configuration at the same time. administrator inactivates 22 WebEye WebEye B101B101 Users Guide 7) Video Configuration This page is to configure every channel with various conditions.
(1) Video Channel State Control Administrator decides whether to utilize video signal from selected channel in WebEy e or not. If user disables a channel with an external camera connecting to WebEye, WebEye does not show any image from the channel.
(2) Camera Color Type It is to define every camera whether it is color or B/W camera. This is not to change its original character but only to define the character and give information to WebEye.
(3) Camera Signal Type It is to define CCD module of WebEye and external CCD cameras between NTSC and PAL.
(4) Camera Installation Angle WebEye can always show images in right angle regardless a dome cameras installation position. If a dome camera is located on the floor upside down, user can adjust image angel by selecting 180 deg.
(5) Advanced Configuration By Clicking Advanced Configuration, you may access the sub page where to configure detailed conditions. Calibration Parameters Administrator manipulates screen settings by adjusting brightness, contrast, hue, saturation, horizontal line shift, and vertical line shift from the menu. With Video Gain menu, you may optimize the image without adjusting each value of other menus. Caption Display Options Administrator may configure caption on real time image with display options such as color and contents. Caption time information, channel information, and additional explanation (user defined string). Visual Setting Parameters Administrator may configure QBOX and image quality level with aid of real time image. By placing the mouse curse on real time image and clicking the left button, you may view pop-up menus. QBOX Parameters : Administrator sets QBOX area with a mouse to click and drag. Selected area shows in Left Top Placement and Right Bottom Placement panels in figures. With Ambient Level to be made of is 23 WebEye WebEye B101B101 Users Guide menu, Administrator may set quality level of unfocused area in the image (out of the focused range). Image Quality Level: Administrator chooses image quality level from 0 to 9. If level 9 is chosen, WebEye sends the finest image. However, transmission speed will be reduced because of larger sized data. The image level inside the QBOX is the same level as is selected in this menu. 8) Application Configuration This page is to configure e-mail and file sending function.
(1) Recipient E-mail Address This is to designate a person to receive E-mail.
(2) Senders E-mail Address This is to put a person s e-mail address that is considered as the e-mail sender. The e-mail sender can be a person who should take care of the situation when events occur. E-mail will be delivered to a person who is defined as a recipient in the blank of E-Mail Recipient. The person who received e-mail can send a message of countermove to a person who is defined as an e-mail sender.
(3) Check E-Mail Options Relay Mail Server: With the same problem of e-mail blocking, WebEye has a function to relay its e -mail through an available e-mail server so that e -mail can have the relay servers domain name. After activating User Relay Mail Server menu, you key in a servers domain name such as @abcdefg.com. Content-Transfer-Type: It is to define e-mail format. E-mail servers support Base64 format in common, but some servers not. In the case, you may select the format as Quoted Printable.
(4) E-Mail Event Configuration Event source: Administrator should define with which event E-mail is to be delivered among MD (motion detection), sensor 1, sensor 2, sensor3, and sensor 4. If administrator clicks on sensor1, e-mail is sent when the sensor1 detects events. (To utilize sensor input detection, a sensor should be connected to WebEye.) File name: With the images of MD and Sensor event, a file is named combining all options. And with the image of periodic sending event, administrator may decide how to name image files among three methods. Administrator names a file with data & time (DATETIME; E.g IMG-CH00-2001030-223031.eye) or serial number (SEQNUM; E.g. IMG-CH00-SN1.eye). The image file has its extension of eye so that the file is to be reproduced on Internet browser. Image quality: Administrator may set images resolution that is delivered by e-mail. Resolution is to be set among 90x60, 180x121, 360x243, 720x243, and 720x486. An image of 90 by 60 is of the lowest resolution and the smallest size.
(5) FTP directory configuration 24 WebEye WebEye B101B101 Users Guide Administrator assigns FTP server address, FTP user account, FTP user password, and FTP user path to receive files when events occur.
(6) FTP event configuration Administrator may set sending conditions, image resolution, and filename. Image resolution, filename, and sending conditions setting methods for FTP are same as that of e-mail. 9) Pan/Tilt/Zoom Configuration This page is to select which serial port to use and to configure PTZ functions such as Mode , Preset, etc.
(1) Select Serial Port It is to select a serial port among Serial
#1, Serial #2, and Serial #3 with which a pan/tilt/zoom control receiver is connected to WebEye. Serial #1 and Serial #2 are RS232C interfaces and Serial #3 is RS422/RS485 interface.
(2) Serial Port Base Address This menu is to identify the base addresses between WebEye and a dome camera. Administrator may connect analogue PTZ controller as well as WebEye B101 to a dome camera. And an analogue PTZ controller can be connected with several dome cameras.
(3) Advanced You may register preset points and configure mode. When you register preset, you would better stop other user control PTZ mechanism. If not, other users may disturb you in setting preset. New Preset You register a new preset point as follows. You may register up to 64 presets. Focus on a certain point to register as a preset point controlling PTZ mechanism. Click New Preset button, then a dialog box New Preset appears. Select a number from 1 to 64 Set the preset name. Click Add/Change button In Current Preset List panel, you may view preset points that are registered currently . At the bottom of this window, you may check if the selected number is occupied or not. New Group You make a new group with combining registered presets. You may make and list up to 6 groups. Each group is to contain 64 points. The procedure to make a group is as follows. Click New Group button, then a dialog box New Group appears. Select a number from 1 to 6. Set the group name. Set interval time. This signifies a duration from time when to move to the next preset point to time when to move to the one after the next preset point. List proper preset point among registered ones in Current Group Member. According to the order that 25 WebEye WebEye B101B101 Users Guide you listed in a group, a dome camera travels. Click Add/Change button In Current Group Member panel, all registered preset points appear. At the bottom of this window, you may check if the selected number is occupied or not. Mode There are three modes like Normal Mode, Swing Mode, and Group Mode. Under normal mode, user may control PTZ mechanism of a dome camera with corresponding buttons in control panel. If you activate Give/Take Mode each user is to be permitted to control the PTZ mechanism for a certain period of time on a first-come-first-served basis. If swing mode is selected, the connected dome camera swings between the designated points. Time duration of Wait (some) seconds signifies the same meaning that of group mode. If group mode is selected, the dome camera travels among listed preset point according to the listed order. 10) Serial Port Configuration This page is to select a communication protocol among listed ones.
(1) Serial Port Selection Administrator selects a serial port to configure. WebEye B101 has three serial ports. Serial #1 and Serial #2 are RS232C interface ports, and Serial #3 is a RS422/RS485 interface port.
(2) Select Attached Device Administrator selects a communication protocol that an attached external device satisfies among already listed protocols. WebGate has listed protocols of Philips, Pelco (P and D), Sensormatic, and Video Technical. Audio Device This protocol is for WebEye A10, which is an audio transmission device connected to WebEye B101. Control Parameters With listed protocols of Philips, Pelco, Sensormatic and VT, you may also configure its control parameters such as Baud Rate, Stop Bits, Data Bits, and Parity Check according to connected dome camera settings. Manual Setting If your mechanism doesnt use any of already listed protocols, you may define the protocol manually by selecting Manual Setting and set parameters through Control Parameters and PTZ CMD menus. 11) Digital I/O Configuration is This page is to configure digital input status. This related with E-mail and FTP applications and PTZ preset points.
(1) Device Type for Input Ports Administrator defines active state of 4 digital input ports. If you connect normal open type 26 WebEye WebEye B101B101 Users Guide device to input port, you should select NO (Normal Open). With normal close type device, you should select NC (Normal Close).
(2) Current State for Input Ports WebEye shows current states of the 4 digital devices connected to 4 input ports. In the status panel, active state or de-active state message shows. De -Active State means that connected device didnt detect any event when Apply button is clicked. 12) Alarm Configuration
/ FTP This page is to set conditions for recording images during event situation, so that WebEye sends the images through e-mail or FTP.
(1) Motion Detection Threshold Administrator sets threshold for motion detection function. Threshold 0 is the most sensitive state and 900 is the dullest state.
(2) Alarm Parameters for E-mail Application Administrator defines conditions for recording image to WebEye, if WebEye detect events through motion detection unction (MD Event) or external devices (SID1, SID2, SID3, and SID4). WebEye can record 2 frames for 2 seconds before the event and 2 frames for 2 seconds after the event as well as 1 frame at the moment of event. Its maximum recording rate is 1 frame per second and the total fames are maximum 5. WebEye records the images and send them through e-mail or FTP according to preset conditions on Application Configuration page and Alarm Configuration page. If event lasts long,
(3) Alarm Preset This is to match a certain preset point to one of the external devices such as an infrared sensor. You may designate any of registered preset point for each external device. If you enabled this function with matching a certain preset with a external sensor, the connected dome camera pans, tilts and zooms to preset degrees. 13) User Custom Configuration This page is to customize TCP ports of data transmission and default viewer composition.
(1) Web Server TCP Port Administrator assigns a web server TCP port through which people can access WebEye and WebEye sends data. 80th port is assigned default value.
(2) Video Server TCP Port Administrator assigns a video server TCP port through which WebEye transmits images to users. 8080th port is assigned as default value. 27 WebEye WebEye B101B101 Users Guide
(3) Select Main Page Administrator assigns a viewer as a main page that appears when users access WebEye. Administrator can select between Default Viewer and 720x486 Viewer. Default Viewer is to show images with maximum resolution of 360 by 243 and 720x486 Viewer shows images with maximum resolution of 720 by 486
(4) Default Viewer Editing Default Viewer is designed for users to edit easily. Editable parts are as bellows. Main Title: It is to change the title that is written on the bottom of the real-time image viewer. Logo Image Source URL: Administrator may assign a path of a certain directory from the inside the WebEye or a URL of a certain Web site where the logo is. Logo Image Link URL: Administrator may link the logo with a certain web page. User can link the logo with a company homepage or a personal one. Background Color and Foreground Color: Ground color of login page can be changed. Administrator may set the color with RGB value. 28 WebEye WebEye B101B101 Users Guide
(Appendix 1) 1. General Detailed Specifications of WebEye B101 720X486, 720X243, 360X243, 180X121, 90X60 10:1 ~ 200:1 1Ch. Video Input 1Ch. Video Output 32bit RISC Embedded processor 8Mbyte 16Mbyte Embedded Linux Hardware CPU Flash memory RAM OS Video Channel NTSC or PAL video format are supported Image Resolution Control Image Compression Compression Algorithm Wavelet Compression Rate Performance Transfer Rate Max up to 120fps (With 3KB image) Decoding Rate 2 ~ 30fps Local Compression rate Max 30fps Security Alarms and I/O MISC. function High quality image area setting Power Supply Password (Based User Authentication) IP-filtering (Secure Mode) Image Encryption Motion detection Sending e-mail automatically Sending the images files through FTP automatically Software -controlled 4 alarms input Image quality Control (10 Levels) Periodical sending the images through E-Mail, FTP Gray/Progressive/Single-Shot Mode User customized home page publishing supported by FTP DC 12V, 1.0A or AC 24V via external power supply 2. Network Browser Connector Installation Protocols supported S/W Update Management MS Internet Explorer Ver 4.0 or later Netscape Ver 4.5 or later JAVA Applet for non PC User (MAC or Unix) 10 Based-T Ethernet (RJ-45) Assign IP address using setup program or ARP, RARP protocol TCP/IP, HTTP, ARP, RARP, ICMP, DHCP, FTP, SMTP and PPPoE Flash memory allows central remote software updates over the network using FTP or private 'WebyeUpgrade' program. Configuration is achieved by private setup program And Web server built in administration page. 29 WebEye WebEye B101B101 Users Guide 3. Mechanical Dimension Weight 4. Environmental H x W x L = 35mm x 120mm x 120mm 350g
-5 C ~ +50 C, Gradient 15 C/Hr max
-20 C ~ +60 C, Gradient 15 C /Hr max 8% ~ 90% R.H. No condensation 8% ~ 90% R.H. No condensation
(*) This data is a target specification. Temperature *
Operating Non-Operating Humidity *
Operating Non-Operating Vibration *
Acceleration Frequency Sweep Time Shock *
1.2G 10Hz ~ 60Hz 1 OCT/Min 10 G (10msec half sine wave Repeated twice maximum/sec) 5. Compatible external devices and software PTZ control Sensor input 2 Ch. RS-232 and 1Ch. RS -422/RS-485 4 auxiliary inputs are supported, and is made of Opto coupler Opto coupler stands with 3-5V and 10-20mA 30 WebEye WebEye B101B101 Users Guide
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2002-09-30 | JBP - Part 15 Class B Computing Device Peripheral | Class II permissive change or modification of presently authorized equipment | |
2 | 2001-11-09 | JBP - Part 15 Class B Computing Device Peripheral | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 | Effective |
2002-09-30
|
||||
1 2 |
2001-11-09
|
|||||
1 2 | Applicant's complete, legal business name |
WebGate Inc.
|
||||
1 2 | FCC Registration Number (FRN) |
0005047980
|
||||
1 2 | Physical Address |
4F Pika Bldg. 894-20 Hokye2-Dong, Dongan-Ku
|
||||
1 2 |
Anyang, N/A 431-836
|
|||||
1 2 |
South Korea
|
|||||
app s | TCB Information | |||||
1 2 | TCB Application Email Address |
j******@baclcorp.com
|
||||
1 2 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 2 | Grantee Code |
PZ9
|
||||
1 2 | Equipment Product Code |
WB101X-WG1K
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 | Name |
R**** C****
|
||||
1 2 | Title |
R & D center Team leader
|
||||
1 2 | Telephone Number |
+82-3********
|
||||
1 2 | Fax Number |
+82-3********
|
||||
1 2 |
r******@webgateinc.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 2 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
1 2 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 | Equipment Class | JBP - Part 15 Class B Computing Device Peripheral | ||||
1 2 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Web Server Camera | ||||
1 2 | Internet Phone | |||||
1 2 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 | Modular Equipment Type | Does not apply | ||||
1 2 | Purpose / Application is for | Class II permissive change or modification of presently authorized equipment | ||||
1 2 | Original Equipment | |||||
1 2 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 2 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 | Grant Comments | Note: This grant was issued for the C2PC approval. The applicant did not modify the EUT itself. The EUT will be marketed with a different power adapter. For this purpose, a new model name was assigned to this C2PC device. | ||||
1 2 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 | Firm Name |
Korea EMC Laboratory Co., Ltd
|
||||
1 2 | Name |
M**** C****
|
||||
1 2 | Telephone Number |
82-31********
|
||||
1 2 | Fax Number |
82-31********
|
||||
1 2 |
m******@koreaemc.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15B | |||||||||||||||||||||||||||||||||||||||
1 | 2 | 15B | |||||||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 15B |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC