TM 58KHz WiFi Floor Guard & Door Guard EAS Systems
(EAS5.0 ver1.6 AM board) Installation Manual March 2015 Manual Ver. 03261501 WARRANTY DISCLAIMER WG Security Products Inc. makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Further, WG Security Products Inc. reserves the right to revise this publication and make changes from time to time in the content hereof without obligation of WG Security Products Inc. to notify any person of such revision or changes. CRITICAL NOTES As specified by FCC Regulations 15.21, any changes or modifications not expressly approved by the party responsible for compliance of this equipment, will void the users permission and authority to operate this equipment. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. instruction manual, may cause harmful interference the WG SECURITY PRODUCTS INC. 2105 S. Bascom Ave., Suite 316, Campbell, CA 95008 (USA) http://www.wgspi.com Technical Support Contact Information North America South America Tel: 408-241-8000 Fax: 408-559-2073 Email: service@wgspi.com Tel: +49 8654 7715-0 Rest of World Fax: +49 8654 7715-29 Email: support@wgglobal.eu TABLE OF CONTENTS OVERVIEW ..................................................................................................................... 1 System Overview ......................................................................................................... 1 System Configurations ................................................................................................. 2 Product Codes and Descriptions ................................................................................. 3 Specifications .............................................................................................................. 4 CONTROLLER CIRCUIT BOARD .................................................................................. 5 WiFi Main Board Connectors ....................................................................................... 5 System Configuration .................................................................................................. 6 PRE-INSTALLATION INFORMATION ............................................................................ 7 Quick Start for System Connections ............................................................................ 7 SMART POWER SUPPLY (WG SPS-24) ..................................................................... 12 Controls and Connections ......................................................................................... 12 Terminals Description ................................................................................................ 13 Main AC Input and Voltage Setup ............................................................................. 14 External Relay interface ............................................................................................. 15
(THIS PAGE INTENTIONALLY LEFT BLANK) WiFi Floor Guard & Door Guard EAS Systems OVERVIEW System Overview All WIFI EAS Systems utilize a common controller, differing only in the antennas that are used. Pedestal controllers (Ad Guard, Ad Guard XL, Premier Guard and Premier Pro) are imbedded in the pedestal base. Door Guard and Floor Guard controllers are contained in a separate housing. In either case, the controller is comprised of a main circuit board for performing all the functions of transmitting, receiving and alarm notification. The power board facilitates all the antenna transmission. This manual applies to the WiFi Floor Guard and WiFi Door Guard. Door Guard and Floor Guard Antennas These modules contain only the antennas whose operation and power are derived from the separate Control and Adaptor boxes. WiFi Control and Adaptor Boxes The Controller Box contains the WiFi Controller and PSU (WG SPS-24) for controlling the antenna and processing tag data. Between the Control Box and Antenna is the Adaptor Box which ensures signal stability between the WiFi Controller and the antennas. The Control Box includes WiFi capability so that the systems can be synchronized and tuned remotely over the Internet. WiFi Door Guard WiFi Floor Guard WiFi Controller WG SPS-24 WiFi Control Box WiFi Adapter Box 1 WiFi Floor Guard & Door Guard EAS Systems System Configurations Each WiFi system is powered by its own dedicated SPS. The SPS not only provides 24vac power to the transceiver pedestal, but it includes some very important features. Accepts a wide range of AC input voltage Controls transmitter bursts for troubleshooting Adjusts pedestal alarm volume Provides alarm visual & audio indication and relay output Provides Jammer Detection alarm and relay output 24vac power and data/control is carried by a single TX cable from the SPS to the controller. The WiFi Control Box can only be connected to only one adaptor and from that to only one antenna. Caution! One WiFi Control Box can only be connected with one antenna and Adapter Box. 2 WiFi Floor Guard & Door Guard EAS Systems Product Codes and Descriptions Systems Product Code Description Comment WG WFFG Floor Guard WiFi Transceiver, 6-foot WG WFDG Door Guard WiFi Transceiver, Gray WG WFDG-B Door Guard WiFi Transceiver, Black WG WFDG-W Door Guard WiFi Transceiver, White WG SPS-24 Smart Power Supply (24vac) Includes antennas, WiFi Control Box and Adaptor Box. Includes antenna, WiFi Control Box and Adaptor Box. Includes antenna, WiFi Control Box and Adaptor Box. Includes antenna, WiFi Control Box and Adaptor Box. Ordered separately but mounted inside the Control Box Accessories, Spares and Options Product Code Description Comment WG WFCB WiFi Control Box (with WG SPS-24)
(N/A) Adaptor Box Included with WG WFFG and WG WFDG Included with WG WFFG and WG WFDG 3 WiFi Floor Guard & Door Guard EAS Systems Specifications Smart Power Supply (WG SPS-24) Electrical Primary Input
(Stepdown Transformer) Secondary Output Rated Output Current Maximum Secondary Output Current 100vac 10 %
110vac 10 %
120vac 10 %
220vac 10 %
240vac 10 %
26Vac 5 %
1.8A 1.9 A Built-in Fuse (self-resettable) 500mA Smart Power Supply (WG SPS-24) Mechanical Height Width Thickness Weight 80mm ( 3.15 ) 110mm ( 4.33 ) 140mm ( 5.5 ) 3 Kg ( 6.6 lbs) Environmental (Antenna, Control Box, Adaptor Box and Power Supply) Operating Temperature 45 C (113F) Relative Humidity 0 to 85% non-condensing Mechanical (Antenna, Control Box and Adaptor Box) Floor Guard Antenna 59.25L x 15.75W (150.5cm x 40cm) Thickness 1.13 (2.9cm) Weight 33 lb. (15kg) Door Guard Antenna 59H x 9.5W x 1.75D (150 x 24 x 4.4cm) Control Box Weight TBD Dimensions TBD Weight TBD Adaptor Box 7.75 x 7.5 x 3.5 (197 x 190 x 90cm) Weight TBD 4 WiFi Floor Guard & Door Guard EAS Systems CONTROLLER CIRCUIT BOARD WiFi Main Board Connectors WiFi Module TX Connector RX Connector Alarm Connector 5 WiFi Floor Guard & Door Guard EAS Systems
(Blue)
(Green) RX Signal Receiver Antennas Transmitter Antenna Connections Legend TX Loop Driving Cable WiFi Adapter Box WiFi Floor antenna System Configuration Transmit and receive antennas are connected to the WiFi Control Box through the Adapter Box. The following diagram illustrates the connections. WiFi Control Box WiFi Door Guard
--OR--
6 WiFi Floor Guard & Door Guard EAS Systems PRE-INSTALLATION INFORMATION Quick Start for System Connections A Floor Guard system consists of a smart power supply (WG SPS-24), WiFi Control Unit, Floor Antenna and Adapter box. A Door Guard system consists of a smart power supply (WG SPS-24), WiFi Control Unit, Door Guard and Adaptor Box. Connection between the various modules is identical. The smart power supply has a 6-pin output connector for the 24vac output to power the WiFi Controller and also communicate with the control unit for tuning control and remote alarm display features. The WiFi Control Box is powered and controlled by the WG SPS-24 power supply unit. Also the control unit has two 4-conductor connectors for cables that will connect to the WIFI Control Unit AM board. One of the connectors is 4-pin connector for TX transmitting signals from the Control Unit to drive a loop antenna coil. The other connector is a 4-pins connector for RX signals from the Control Unit to receive signals from Floor Guard RX antennas. Note: Both the TX and RX cables are color coded and it is critical not to transpose the order. 7 WiFi Floor Guard & Door Guard EAS Systems J5 J2 J6 J3 J7 J7-1 WIFI Control Unit and Adapter box and antenna Connection P3 White White P3 P4 P2 Brown P1 Red P1 Red P2 P1 J4-1 J4 J3 J1 P4 P2 Green Red P3 P1 White Green Blue P2 P3 8 J1 J2 J6-1 J5-1 J5 J5-1 P4 Green P4 Orange WiFi Floor Guard & Door Guard EAS Systems SW5 J3 port of Adapter Box connects to the Transmit antenna (2 white wires). J1 port of the Adaptor Box connects to the figure O antenna. J2 port of the Adaptor Box connects to the figure 8 antenna. At this time there is no connection required for figure 8; only figure O. J5 port of the Adaptor Box connects the RX antenna to Adapter PCB (2pcs 2-core wires). J5-1 port of the Adaptor Box is the output port for RX antenna. SW5 is antenna phasing adjustment switch. Use this switch to adjust if the site is too noisy. P1 Brown Red P3 P4 P6 P7 P8 P2 P1 P2 P3 P4 P5 White Green Blue Orange 9 WiFi Floor Guard & Door Guard EAS Systems TX 8 debug jumper TX ampere debug Connect transmit detector to J1, turn on the power supply of CB and transmit detector, adjust TX O debug jumper, from the bottom the up. System will be under optimum working status when the transmit detector shows a value from 17 to 22. TX O debug jumper 10 WiFi Floor Guard & Door Guard EAS Systems Antenna Installation Instructions:
The antenna is designed to be buried in the flooring, in a rectangular of sufficient size to conveniently fit the antenna size. Coverage may be standard flooring (concrete or wood material). There is a cable extending out of the antenna case. Ensure the connector end is extended far enough for service access. Distance from the Antenna Box to the antenna should be no more than 25 feet. Distance between the Antenna Box and Controller should be no longer than the included interconnect cable. 11 WiFi Floor Guard & Door Guard EAS Systems SMART POWER SUPPLY (WG SPS-24) Main AC Power In Controls and Connections Fuse Replacement:
Internal AC fuse rating
(T3.15AL, 250V) TX Antenna On/Off Switch Select Switch B Input Voltage SPS Power On/Off Switch Caution! Remove power before service. Input Voltage Select Switch A Pedestal Alarm Volume Adjust 24vac Power & Data Output SPS Front View SPS Top View SPS Rear View 12 WiFi Floor Guard & Door Guard EAS Systems Main AC Input Terminal SPS Main AC Input Terminal Layout Main AC Cable (3 wires) Pin Function Color 1 Neutral Blue 2 Ground Green w/Yellow Stripe 3 Red(Brown) Live 3 2 1 Pin:
N - GND - L Terminals Description Pin:
1 2 3 4 5 LED Status LED On Off TX Off TX is Off TX is On System Alarm Alarm Enabled Jammer Detection Detection Enabled Alarm Disabled Detection Disabled Alarm Volume Dim Means Bright Means Weaker Louder 6 7 8 9 10 SPS Output Terminal Layout (10 pins) SPS to Pedestal Cable (6 wires) Alarm Relay Jammer Relay Pin #
1 2 3 4 5 6 7 8 9 10 Function GND 24VAC TX OFF Alarm Anti-
Jammer Alarm Volume Electrical Common GND 26 VAC
>4.0vdc
<2.5vdc
<2.5vdc 5-15vdc 1A 1A Contact Contact I/O Output Output Output Input Input Output Output Output 13 WiFi Floor Guard & Door Guard EAS Systems AC Power In Voltage Switch A Voltage Switch B Main AC Input and Voltage Setup The Smart Power Supply (WG SPS-24) accepts 5 input voltages: 100vac 110vac and 120vac in North America and Japan, 220vac and 240vac in Europe and Australia. Caution: Set the two Voltage Switches (A and B) on the power supply at the specified combination based on the local incoming voltage value (see picture below). HIGH MID LOW
(Three Positions) 220vac Voltage Switch A - 230 240vac Voltage Switch A - 230 120vac Voltage Switch A - 115 Voltage Switch B - HIGH 100vac Voltage Switch A - 115 110vac Voltage Switch A - 115 Voltage Switch B - MIDDLE Voltage Switch B - HIGH Voltage Switch B - LOW Voltage Switch B - MIDDLE 14 Suggested Relay Ratings 1A@ 24 VDC Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Pin 10 Last 4 pins on this end. WiFi Floor Guard & Door Guard EAS Systems External Relay interface The external relay interface is located at Output side of the SPS. Pin #
SPS to Pedestal Cable (6 wires) Alarm Volume Jammer Anti-
3 4 6 1 2 5 Function GND 24VAC TX OFF Alarm Electrical
***
15 Notes:
1. Wire length to the dry contact circuit is limited to 20 feet. 2. To prevent high voltage noise from being introduced into the transceiver and degrading the systems performance, it is highly recommended that you use a 24vdc output relay. Power Supply Output Terminal Layout (10 pins) Alarm Relay 7 8 Jammer Relay 9 10 1A 1A Contact Rating Contact Rating