Report Number: 68.940.21.0029.01A 1. 2. RF exposure Estimation Introduction RD030015DG (FCC ID: WUI-RD030015DG) is a LED LINKABLE SHOPLIGHT, which contain 5.8GHz Microwave function inside. Note: The radio module does not have shielded cover, so it was tested with a host for this Modular approve application, the host information as below:
Company name: Winplus Co., Ltd. Product/PMN: 46 LED LINKABLE SHOP LIGHT Model no./HVIN: LM030015 Limit and Guidelines on Exposure to Electromagnetic Fields According to 1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of the Commissions guideline. According to KDB 447498 D01 General RF Exposure Guidance v06, Mobile Portable RF Exposure, no SAR required if power is lower than the flowing threshold:
The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]
[f(GHz)] 3.0 for 1-g SAR and 7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation25 The result is rounded to one decimal place for comparison 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below The test exclusions are applicable only when the minimum test separation distance is 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion. Calculation method
[(max. power of` channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] [f(GHz)] 3.0 According to ANSI C63.10-2013 (9.5 Equations to calculate EIRP), TV SD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Report Number: 68.940.21.0029.01A Field Strength (EMeas):
Measurement Distance(dMeas):
Equivalent Isotropically Radiated Power(EIRP):
75.88 (dBuV/m)
(f=5862Hz) 3 (m) 0.0118 (mW) Radiated Power + tune up tolerance = 0.0118 mW Distance = 5 mm f = 5.862 GHz
[0.0118/5] * SQRT(5.862) =0.0057 0.0057 3.0 Therefore, excluded from SAR testing. TUV SUD China, Shenzhen Branch Reviewed by: Prepared By:
Dawi Xu/ EMC Project Manager Henry Chen/EMC Project Engineer Date: 2021-05-13 Date: 2021-05-13 TV SD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299