all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 538.54 KiB | March 12 2007 | |||
1 | Test Report | March 12 2007 | ||||||
1 | Block Diagram | March 12 2007 | ||||||
1 | Schematics | March 12 2007 | ||||||
1 | External Photos | March 12 2007 | ||||||
1 | Internal Photos | March 12 2007 | ||||||
1 | ID Label/Location Info | March 12 2007 | ||||||
1 | Test Setup Photos | March 12 2007 | ||||||
1 | Operational Description | March 12 2007 | ||||||
1 | Test Report | March 12 2007 | ||||||
1 | Test Report | March 12 2007 |
1 | User Manual | Users Manual | 538.54 KiB | March 12 2007 |
Operating Instructions 1UHG7 5. Press [L/M] to change control temperature for cool. Hold for fast advance changes. Press [PROG] to select. Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Dayton LCD Programmable Wireless Thermostat Description The RF Remote Control Programmable Thermostat has LCD display; 5-1-1 (Mo-Fr, Sa, Su) programming with 4 time zones for each program. Programmed temperature range from 41F to 95F, in step of 0.5F. Unpacking 1. Remove all packing items applied to thermostat for shipment. 2. Remove all items from carton. 3. Check all items for shipping damage. If thermostat is damaged, promptly inform dealer where you purchased thermostat. Features Voltage supply 3.0 VDC; AA alkaline batteries (2). Temperature measuring 32 to 99F (0 to 39.5C);
Resolution: 1F (0.5C) LCD display for Day, Time, Real Temperature/Control Temperature. LCD display for HEAT/COOL/ AUTO/OFF control. Fan ON/AUTO. 5-1-1 (Mon-Fri, Sa, Su) with 4 time zone programming. Temporary Override of a running Program temperature until next program time meets. Permanent Override maintains room temperature at a specific temperature for long-term period. Defrost indicator for room temperature below 41F (5C). Low battery indicator for battery level at or below 2.6 V. Transmit indicator stays on when RF signal is being transmitted. 12/24 selectable. Span +2/-1F (+1/-0.5C) for HEAT/COOL/AUTO mode. Dual Set point control in AUTO mode. Up to 512 addresses can be chosen by the user. Filter Over-use Alert FILTER indicator will flash auto-
matically when the fan/blower is operated over a specific value. DIP SWITCHES Long Cycle Delay is approximately 4 ~ 5 minutes and Short Cycle Delay is approximately 5 ~ 10 seconds. Switch 1 To select C or F temperature (On: F, Off: C) Switch 2 To select between Electrical Heating System and Gas Heating System (On: HG, Off: HE) Switch 3-11 To set the Transmitter address Switch 12 No use DEFAULT SETTING AFTER RESET 1. Real temperature: F/C; Real Temperature will be displayed after ~5 seconds. 2. Control Temperature: Degree : 70F (21C) (HEAT);
75F (24C) (COOL). 3. Normal Time: 12:00 AM/MO (12 HR display format). 4. Default Control Mode: System Off Mode. 5. Default Fan Mode: Auto Mode. 6. Default Program Mode: Program OFF. NORMAL TIME MODE (NT) After reset or battery replacement, the controller enters the NT mode with real temperature, current time (default:
12:00 AM & MO) displayed at the LCD; System set at OFF;
Fan set at FAN AUTO. DAY/TIME SETTING MODE TIME AND DAY SETTING 1. At Normal Time mode, press [D/T] key to enter Day/Time setting mode. 2. HH:MM starts flashing. Press [L/M] to change current minutes. Hold for 10-minute fast advance changes. 3. Press [D/T] again, current Day is flashing. Press [L/M]
to change current day. Hold for faster changes. 4. Press RTN to return to Normal Time Mode. 5. Auto-return to Normal Time Mode if no key input for 10 sec. 12-HOUR OR 24-HOUR SYSTEM Press [D/T] key for 2 seconds in Normal Time mode to toggle between 12-hour and 24-hour system. PROGRAM SETTING MODE Usage Alert USAGE indicator will flash automatically See chart below for default program settings. when the heater/ cooler is operated over a specific value. Operation USER INTERFACE Figure 1 LCD PUSH BUTTONS Description Up Down System Fan Day/Time Program On/Off Return Reset Form 5S5720 Symbol L M SYS FAN D/T PROG ON/OFF RTN RST Printed in China 09663 0507/097/VCPVP WEX001 05/07 MO-FR
(HEAT/COOL) SA
(HEAT/COOL) SU
(HEAT/COOL) E K A W T U O K C A B T H G N I 06:00 am 70F/75F
(21C/24C) 08:00 am 62F/83F
(17C/28C) 06:00 pm 70F/75F
(21C/24C) 10:00 pm 62F/78F
(17C/26C) 08:00 am 70F/75F
(21C/24C) 10:00 am 62F/83F
(17C/28C) 06:00 pm 70F/75F
(21C/24C) 11:00 pm 62F/78F
(17C/26C) 08:00 am 70F/75F
(21C/24C) 10:00 am 62F/83F
(17C/28C) 06:00 pm 70F/75F
(21C/24C) 11:00 pm 62F/78F
(17C/26C) MODIFYING THE PROGRAM SETTINGS 1. At Normal Time mode, press [PROG] key to enter Program Setting mode. 2. The first program slot will be displayed. Icons MO TU WE TH FR & WAKE will be on, HH:MM will flash. 3. Press [L/M] to change program minutes. The program minutes is set in increments of 10 minutes. Hold for fast advance changes. Press PROG to select. Control Temperature and HEAT icon will flash. 4. Press [L/M] to change control temperature for heat. Hold for faster changes. Press [SYS] to toggle the Control Temperature for cool (COOL icon will flash). 7. 6. The next program slot will be displayed. Icons MO TU WE TH FR and OUT will be on, HH:MM will flash. Repeat steps 2, 3, 4 to change the program settings for other program slot. If necessary, press [ON/OFF] to disable programming of the current program slot. --:-- -- will be seen to indicate current program slot is disabled. Press [ON/OFF] again to enable programming of the current program slot. 8. Press [RTN] to return to Normal Time Mode at any time. 9. Auto-return to Normal Time Mode if no key input for 10 sec. ACTIVATING PROGRAM ON MODE At startup, the default program mode is off; that is, the thermostat is in Permanent Override mode. Press [ON/OFF]
to toggle between Program On mode and Permanent Override mode. MANUAL OVERRIDE MODE 1. When program is On and System is at Heat or Cool, press 2.
[L] or [M] to temporarily override program settings. In AUTO mode, press [L] or [M] to modify the heat set point. Press [SYS] to set the cool set point. The minimum difference between HEAT & COOL Set point is preset to 5F (3C). 3. Manual override mode maintains until next program time is met. PERMANENT OVERRIDE MODE When the room temperature should be maintained at a certain temperature for a long time, Permanent Override Mode should be used. Press [ON/OFF] to toggle between Program On mode and Permanent Override mode. FILTER AND SYSTEM USAGE Every time the Fan is activated, the number of running hours is counted. When the counter value reaches the Filter Usage check interval, FILTER icon will flash to indicate it is time to check the air filter. Every time either HEAT or COOL is activated, the number of running hours is counted. When the counter value reaches the System Usage value, Usage icon will flash to indicate that the Heating or Cooling system has been run for a certain number of hours. The value of Filter Usage check period and System Usage can be set from 0-3000 hours, in an interval of 100 hours.
(If the value is set to 0 hr, the counter is disabled.) To modify the Filter Usage check period:
1. Hold [PROG] for 2 seconds in normal time mode. 2. FILTER icon is shown and 1500hr (default) flashes on the screen. 3. Press [L]/ [M] to modify the setting. 4. Press [RTN] to confirm new setting. 5. Usage icon is shown and 1500hr (default) flashes on the screen. 6. Press [L]/ [M] to modify the setting. 7. Press [RTN] to confirm new setting and return to normal mode. Hold [FAN] key for 2 seconds, the Filter Usage counter is shown. Release [FAN] key, it returns to the normal mode. Hold [SYS] key for 2 seconds, the system Usage counter is shown. Release [SYS] key, it returns to the normal mode. LOW BATTERY INDICATOR For battery voltage level below 2.6 VDC, Low Battery indicator is ON. Indicator is refreshed every 10 minutes and refreshed after reset. SYSTEM MODE SELECT SYSTEM MODE System mode can be set by pressing [SYS] key in normal time mode. System mode is set in the sequence of:
OFFHEATCOOLAUTOOFF HEAT mode COOL mode AUTO mode System Mode Heating will be activated when the room temperature is lower than the setting temperature. Cooling will be activated when the room temperature is higher than the setting temperature. Heating or Cooling will be activated according to the Heat and Cool set point. Heat set point and Cool set point must be separated by a 5F/3C dead band. OFF mode No Heating and Cooling will be activated at any temperature. SELECT FAN MODE Fan mode can be set by pressing [FAN] key in normal time mode. Fan mode is set in the sequence of:
FAN AUTOFAN ONFAN AUTO Fan Mode Fan turns On whenever Heating or Cooling is On. (Depends on HE/HG setting) Fan stays On all the time. Fan auto Fan on HE/HG setting:
Operated at HEAT Operated at COOL HG FAN ON FAN ON HE FAN OFF FAN ON TEMPERATURE MEASURING Take reading at each 10 sec Interval. Accuracy up to
+/-1F (+/-0.5C). Resolution: 1F (0.5C); 32F to 99F (0C to 39.5C). For Temperature above 99F (39.5C), -- will be displayed. For Temperature below 32F (0C), -- will be displayed. TEMPERATURE CONTROL When the program is on and specific program time is met, the specified control temperature will be used to determine the temperature control. One can override the control tem-
perature by pressing [L]/ [M] to desired control temperature. Temperature control range:
System Mode HEAT MODE Fahrenheit Celsius Heat Control Set point 41 to 95 5 to 35 COOL MODE Cool Control Set point 41 to 95 5 to 35 AUTO MODE Heat Control Set point Cool Control Set point 41 to 90 46 to 95 5 to 32 8 to 35 Control resolution is 1F (0.5C). 1. System set at HEAT:
1. SPAN: +2/-1F (+1/-0.5C):
Heater ON: Real Temperature
<= Control Temperature 1F (0.5C) Heater OFF: Real Temperature
>= Control Temperature +2F (1C) 2. System set at COOL:
1. SPAN: +2/-1F (+1/-0.5C):
Cooler ON: Real Temperature
>= Control Temperature +2F (1C) Cooler OFF: Real Temperature
<= Control Temperature 1F (0.5C) 3. System set at AUTO:
AUTO means the system can be switched to HEAT or COOL automatically according to the control temperature. In the Auto mode, the Cool setting temperature must be higher than the heat setting temperature with 5F/ 3C or above, but it does not restrict to the heat mode and cool mode. 1. SPAN: +2/-1F (+1/-0.5C):
Heater ON Automatically: Real Temperature
<= Heat Control Temperature 1F (0.5C) Cooler ON Automatically: Real Temperature
>= Cool Control Temperature +2F (1C) Heater and Cooler both off when Real Tempera-
ture is inside the off zone (i.e. the minimum distance between the Heat & Cool Set points). Windmill indicator starts to turn when Heat/Cool/Auto condition & delay condition are both satisfied. The windmill indicator stays on and will not turn unless the delay condition is fulfilled. The windmill indicator disappears when system is off. Delay for Heat On and Cool On is to prevent short cycling of system. Setting of delay dip s/w at Controller System operated at HEAT System operated at COOL 5-10 sec. 4-5 min. 4-5 min. 4-5 min. No Delay Delay DEFROST (SYSTEM IS SET AT HEAT/AUTO) For Real temperature below 41F (5C) and sufficient delay time, HEATER is always ON and COOLER is always OFF, regardless of the current control temperature set. LCD DEFROST indicator ON. UPPER TEMPERATURE LIMIT (SYSTEM IS SET AT COOL/AUTO) For Real temperature above 95F (35C) and sufficient delay time, HEATER is always OFF and COOLER is always ON, regardless of the current control temperature set. RF COMMUNICATION TO SETUP WITH THE RECEIVER 1. Place batteries in the thermostat controller. 2. Ensure the thermostat controller is in the default state
(i.e. SYSTEM is set to OFF, FAN is set to AUTO). This is to ensure that the receiver can receive the correct address from the thermostat controller. 3. Power up the RF receiver, push the ON/OFF dip switch to ON position. 4. Set the thermostat FAN to ON:
The receiver accepts the message and stores the controller identity. The SETUP and the FAN LED are ON. The thermostat is now set to send signals to the receiver. At any time, if you find that the RF receiver gets interference from other wireless thermostat controllers, push the SETUP dip switch of the receiver to OFF posi-
tion. Then change the address code of the thermostat controller by selecting other settings of the 9 dip switch-
es located at the back of the controller. Then reset it and repeat steps 2-4 for each new setup. 5. Setup is completed. You can now set FAN key and SYSTEM key of the thermostat to desired locations. Up to 512 addresses can be chosen by the user in case of interfering with other wireless thermostat controllers. Transmit indicator stays on when RF signal is being transmitted. RF signal is transmitted per 10 minutes for update information. Auto refresh the System & Fan status at the receiver every 10 minutes by RF signal. Toggling relay at receiver side to ON will not happen when sufficient delay time is not met. G Y RHW RC SETUP OFF ON Fan Relay Cool Relay Heat Relay Figure 2 RC RH The RF Receiver Module provides 24 VAC control of HVAC equipment when used with the wireless thermostat controller. It can be used with 1H/1C single-zone conven-
tional applications. NOTE: Before resetting the transmitter, ensure the ON/OFF dip switch is set to OFF in the receiver. After resetting the transmitter, the ON/OFF dip switch in the receiver is set to ON and follows the receiver setup instruction. 1UHG7 FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. LIMITED WARRANTY DAYTON ONE-YEAR LIMITED WARRANTY. DAYTON LCD PROGRAMMABLE WIRELESS THERMOSTAT, MODELS COVERED IN THIS MANUAL, ARE WARRANTED BY DAYTON ELECTRIC MFG. CO.
(DAYTON) TO THE ORIGINAL USER AGAINST DEFECTS IN WORKMAN-
SHIP OR MATERIALS UNDER NORMAL USE FOR ONE YEAR AFTER DATE OF PURCHASE. ANY PART WHICH IS DETERMINED TO BE DEFECTIVE IN MATERIAL OR WORKMANSHIP AND RETURNED TO AN AUTHORIZED SERVICE LOCATION, AS DAYTON DESIGNATES, SHIPPING COSTS PREPAID, WILL BE, AS THE EXCLUSIVE REMEDY, REPAIRED OR REPLACED AT DAYTONS OPTION. FOR LIMITED WARRANTY CLAIM PROCEDURES, SEE PROMPT DISPOSITION BELOW. THIS LIMITED WARRANTY GIVES PURCHASERS SPECIFIC LEGAL RIGHTS WHICH VARY FROM JURISDICTION TO JURISDICTION. LIMITATION OF LIABILITY. TO THE EXTENT ALLOWABLE UNDER APPLICABLE LAW, DAYTONS LIABILITY FOR CONSEQUENTIAL AND INCIDENTAL DAMAGES IS EXPRESSLY DISCLAIMED. DAYTONS LIABILITY IN ALL EVENTS IS LIMITED TO AND SHALL NOT EXCEED THE PURCHASE PRICE PAID. WARRANTY DISCLAIMER. A DILIGENT EFFORT HAS BEEN MADE TO PROVIDE PRODUCT INFORMATION AND ILLUSTRATE THE PRODUCTS IN THIS LITERATURE ACCURATELY; HOWEVER, SUCH INFORMATION AND ILLUSTRATIONS ARE FOR THE SOLE PURPOSE OF IDENTIFICATION, AND DO NOT EXPRESS OR IMPLY A WARRANTY THAT THE PRODUCTS ARE MERCHANTABLE, OR FIT FOR A PARTICULAR PURPOSE, OR THAT THE PRODUCTS WILL NECESSARILY CONFORM TO THE ILLUSTRATIONS OR DESCRIPTIONS. EXCEPT AS PROVIDED BELOW, NO WARRANTY OR AFFIR-MATION OF FACT, EXPRESSED OR IMPLIED, OTHER THAN AS STATED IN THE LIMITED WARRANTY ABOVE IS MADE OR AUTHORIZED BY DAYTON. Technical Advice and Recommendations, Disclaimer. Notwithstanding any past practice or dealings or trade custom, sales shall not include the furnishing of technical advice or assistance or system design. Dayton assumes no obligations or liability on account of any unauthorized recommendations, opinions or advice as to the choice, installation or use of products. Product Suitability. Many jurisdictions have codes and regulations governing sales, construction, installation, and/or use of products for certain purposes, which may vary from those in neighboring areas. While attempts are made to assure that Dayton products comply with such codes, Dayton cannot guarantee compliance, and cannot be responsible for how the product is installed or used. Before purchase and use of a product, review the product applications, and all applicable national and local codes and regulations, and be sure that the product, installation, and use will comply with them. Certain aspects of disclaimers are not applicable to consumer prod-
ucts; e.g., (a) some jurisdictions do not allow the exclusion or limita-
tion of incidental or consequential damages, so the above limitation or exclusion may not apply to you; (b) also, some jurisdictions do not allow a limitation on how long an implied warranty lasts, consequent-
ly the above limitation may not apply to you; and (c) by law, during the period of this Limited Warranty, any implied warranties of implied merchantability or fitness for a particular purpose applicable to consumer products purchased by consumers, may not be excluded or otherwise disclaimed. Prompt Disposition. A good faith effort will be made for prompt correction or other adjustment with respect to any product which proves to be defective within limited warranty. For any product believed to be defective within limited warranty, first write or call dealer from whom the product was purchased. Dealer will give additional directions. If unable to resolve satisfactorily, write to Dayton at address below, giving dealers name, address, date, and number of dealers invoice, and describing the nature of the defect. Title and risk of loss pass to buyer on delivery to common carrier. If product was damaged in transit to you, file claim with carrier. Manufactured for Dayton Electric Mfg. Co., 5959 W. Howard St., Niles, Illinois 60714-4014 U.S.A. Hotline: 888-361-8649 Manual de Instrucciones de Operacin 1UHG7 Por favor lea y guarde estas instrucciones. Lalas cuidadosamente antes de tratar de montar, instalar, operar o dar mantenimiento al producto aqu descrito. Protjase usted mismo y a los dems observando toda la informacin de seguridad. El no cumplir con las instrucciones puede ocasionar daos, tanto personales como a la propiedad! Guarde estas instrucciones para referencia en el futuro. Termostato Inalmbrico Programable con Pantalla LCD Dayton Descripcin El Termostato Programable con Control Remoto RF incluye una pantalla LCD; programacin 5-1-1 (L-V, S, D) con 4 husos horarios para cada programa. Gama de temperatura programada de 5C a 35C (41 a 95F), en lugar de 0.3C (0.5F). Desempaque 1. Retire todos los materiales de embalaje aplicados al minutos y el Retardo de ciclo corto es de aproximadamente 5 a 10 segundos. Interruptor 1 Para seleccionar temperatura C o F
(Encendido: F, Apagado: C) Interruptor 2 Para seleccionar entre Sistema de Calefaccin Elctrica y Sistema de Calefaccin a Gas (Encendido: HG, Apagado: HE) Interruptor 3-11 Para establecer la direccin del Transmisor INTERRUPTORES DIP El Retardo de ciclo largo es de aproximadamente 4 a 5 termostato para su envo. 2. Retire todos los artculos de la caja de envo. 3. Inspeccione los artculos para comprobar que no se hayan daado durante el envo. Si el termostato est daado, infrmele prontamente al concesionario de quien compr el termostato sobre dicho dao. Caractersticas Medicin de temperatura 0 a 39.5C (32 a 99F);
Suministro de voltaje 3.0 VCC; bateras alcalinas tipo AA (2). Resolucin: 0.5C (1F) Pantalla LCD para Da, Hora, Temperatura Real/Temperatura Control. Pantalla de LCD para control HEAT/COOL/ AUTO/OFF
(CALOR/FRIO/AUTO/APAGADO). Ventilador ON/AUTO
(ENCENDIDO/AUTO). 5-1-1 (L-V, S, D) con 4 programaciones de husos horarios. Anulacin Temporal de una temperatura de Programa en ejecucin hasta que se alcance la prxima hora de programa. La Anulacin Permanente mantiene la temperatura ambiente a una temperatura especfica por un largo periodo de tiempo. Indicador de deshielo para temperatura ambiente por debajo de 5C (41F). Indicador de batera baja para nivel de batera a o por debajo de 2.6 V. El indicador de transmisin permanece encendido cuando se est transmitiendo la seal RF. Seleccionable 12/24. Intervalo de +1/-0.5C (+2/-1F) para modo HEAT/COOL/AUTO
(CALOR/FRIO/AUTO). Control de punto de ajuste doble en el modo AUTO. El usuario puede seleccionar hasta 512 direcciones. Alerta sobre uso excesivo del filtro El indicador FILTER
(FILTRO) parpadear automticamente si el ventilador/
soplador funciona por encima de un valor especfico. Alerta sobre el uso El indicador USAGE (USO) parpadear automticamente si el calentador/enfriador funciona por encima de un valor especfico. Operacin INTERFASE DEL USUARIO Figura 1 Pantalla LCD BOTONES PULSADORES Descripcin Smbolo Arriba Abajo Sistema Ventilador Da/Hora Programa Encendido/Apagado Regresar Restablecer Formulario 5S5720 L M SYS FAN D/T PROG ON/OFF RTN RST Impreso en China 09663 0507/097/VCPVP WEX001 05/07 Transmisor 12 No tiene uso AJUSTE PREDETERMINADO LUEGO DEL RESTABLECIMIENTO 1. Temperatura Real: C/F; la Temperatura Real se mostrar luego de 5 segundos. 2. Temperatura Control: Grado : 21C (70F) (CALOR); 24C
(75F) (FRIO). 3. Duracin Normal: 12:00 AM/MO (formato de pantalla de 12 horas). 4. Modo Control predeterminado: Modo Sistema apagado. 5. Modo Ventilador predeterminado: Modo Auto. 6. Modo Programa predeterminado: Programa APAGADO. MODO DURACION NORMAL (TN) Luego de un restablecimiento o reemplazo de batera, el controlador ingresa al modo TN con temperatura real, hora actual (predeterminado: 12:00 AM & MO) mostrado en la pantalla LCD; Sistema ajustado en OFF (APAGADO);
Ventilado ajustado en FAN AUTO (VENTILADOR AUTO). MODO AJUSTE DIA/HORA AJUSTE DE DIA Y HORA 1. En el modo Duracin Normal, oprima la tecla [D/T] para ingresar al modo de ajuste Da/Hora. 2. HH:MM comienza a parpadear. Oprima [L/M] para cambiar los minutos actuales. Mantngalo oprimido para hacer cambios rpidos en incrementos de 10 minutos. 3. Oprima [D/T] nuevamente, Da actual parpadear. Oprima
[L/M] para cambiar el da actual. Mantngalo oprimido para hacer cambios rpidos. 4. Oprima RTN para regresar al modo Duracin Normal. 5. Se produce el regreso automtico al Modo Duracin Normal si no se oprime ninguna tecla en un espacio de 10 segundos. SISTEMA DE 12 HORAS O 24 HORAS Oprima la tecla [D/T] durante 2 segundos en el modo Duracin Normal para alternar entre el sistema de 12 horas y 24 horas. MODO AJUSTE PROGRAMA Consulte la tabla para los ajustes de programa predeterminados. L-V S D
(CALOR/FRIO)
(CALOR/FRIO)
(CALOR/FRIO)
. P S E D A D I L A S O S E R G E R E H C O N 06:00 am 21C/24C
(70F/75F) 08:00 am 17C/28C
(62F/83F) 06:00 pm 21C/24C
(70F/75F) 10:00 pm 17C/26C
(62F/78F) 08:00 am 21C/24C
(70F/75F) 10:00 am 17C/28C
(62F/83F) 06:00 pm 21C/24C
(70F/75F) 11:00 pm 17C/26C
(62F/78F) 08:00 am 21C/24C
(70F/75F) 10:00 am 17C/28C
(62F/83F) 06:00 pm 21C/24C
(70F/75F) 11:00 pm 17C/26C
(62F/78F) COMO MODIFICAR LOS AJUSTES DE PROGRAMA 1. En el modo Duracin Normal, oprima la tecla [PROG]
para ingresar al modo Ajuste Programa. 2. Se muestra el primer periodo horario del programa. Los iconos MO TU WE TH FR (L M MIE J V) y WAKE (DESP.) estarn iluminados, HH:MM parpadear. 3. Oprima [L/M] para cambiar los minutos del programa. Los minutos del programa se establecen en incrementos de 10 minutos. Mantngalo oprimido para hacer cambios rpidos. Oprima PROG para seleccionar. Temperatura Control y el icono HEAT (CALOR) parpadearn. 4. Oprima [L/M] para cambiar la temperatura control para el calor. Mantngalo oprimido para hacer cambios rpidos. Oprima [SYS] para alternar Temperatura Control para el fro (el icono COOL [FRIO] parpadear). 5. Oprima [L/M] para cambiar la temperatura control para el fro. Mantngalo oprimido para hacer cambios rpidos. Oprima [PROG] para seleccionar. 6. Se muestra el prximo periodo horario del programa. Los iconos MO TU WE TH FR (L M MIE J V) y OUT (SALIDA) estarn iluminados, HH:MM parpadear. Repita los pasos 2, 3 y 4 para cambiar los ajustes del programa para otros perio-
dos horarios del programa. 7. De ser necesario, oprima [ON/OFF] (ENCENDIDO/APAGADO) para anular la programacin del periodo horario del programa actual. --:-- -- aparecer para indicar que se ha anulado el periodo horario del programa actual. Vuelva a oprimir
[ON/OFF] (ENCENDIDO/APAGADO) para habilitar el periodo horario del programa actual. 8. Oprima [RTN] para regresar al modo Duracin Normal en cualquier momento. 9. Se produce el regreso automtico al Modo Duracin Normal si no se oprime ninguna tecla en un espacio de 10 segundos. COMO ACTIVAR EL MODO PROGRAMA ENCENDIDO Durante el arranque, el modo programa predeterminado est desactivado; o sea, el termostato se encuentra en el modo Anulacin Permanente. Oprima [ON/OFF] (ENCENDIDO/APAGADO) para alternar entre modo Programa Encendido y modo Anulacin Permanente. MODO ANULACION MANUAL 1. Cuando el programa se encuentra Encendido y el Sistema se encuentra ajustado en Calor o Fro, oprima [L] o [M]
para anular temporalmente los ajustes de programa. 2. En el modo AUTO, oprima [L] o [M] para modificar el punto de ajuste de calor. Oprima [SYS] para ajustar el punto de ajuste de fro. La diferencia mnima entre el punto de ajuste de FRIO y CALOR es preestablecida a 3C (5F). 3. El modo de anulacin manual contina hasta que se alcance la prxima hora de programa. MODO ANULACION PERMANENTE Cuando la temperatura ambiente se debe mantener a un nivel dado por un largo periodo de tiempo, se recomienda utilizar el Modo Anulacin Permanente. Oprima [ON/OFF] (ENCENDIDO/
APAGADO) para alternar entre modo Programa Encendido y modo Anulacin Permanente. USO DEL FILTRO Y SISTEMA Cada vez que se active el Ventilador, se cuenta el nmero de horas de funcionamiento. Cuando el valor del contador alcanza el intervalo de revisin de Uso de Filtro, el icono FILTER (FILTRO) parpadear para indicar que es tiempo de revisar el filtro de aire. Cada vez que se active CALOR o FRIO, se cuenta el nmero de horas de funcionamiento. Cuando el valor del contador alcanza el valor de Uso del Sistema, el icono Usage (Uso) parpadear para indicar que el sistema de Calentamiento o de Enfriamiento ha estado funcionando por un nmero dado de horas. El valor del periodo de revisin del Uso del Filtro y del Uso del Sistema puede establecerse de 0 a 3000 horas en intervalos de 100 horas. (Si el valor se establece en 0, se inhabilita el contador.) Para modificar el periodo de revisin del Uso del Filtro:
1. Oprima [PROG] durante 2 segundos en el modo Duracin Normal. 2. Aparace el icono FILTER (FILTRO) y 1500hr (valor predeterminado) parpadea en la pantalla. 3. Oprima [L/M] para modificar el ajuste. 4. Oprima [RTN] para confirmar el nuevo ajuste. 5. Aparace el icono Usage (Uso) y 1500hr (valor predeterminado) parpadea en la pantalla. 6. Oprima [L/M] para modificar el ajuste. 7. Oprima [RTN] para confirmar el nuevo ajuste y regresar al modo normal. Oprima la tecla [FAN] (VENTILADOR) durante 2 segundos, aparece el contador de Uso del Filtro. Suelte la tecla [FAN]
(VENTILADOR), regresa al modo normal. Oprima la tecla [SYS] durante 2 segundos, aparece el contador de Uso del Sistema. Suelte la tecla [SYS], regresa al modo normal. INDICADOR DE BATERIA BAJA Cuando el nivel del voltaje de la batera se encuentra por debajo de 2.6 VCC, se ENCIENDE el indicador de Batera Baja. El indicador se actualiza cada 10 minutos y luego de un restablecimiento. MODO SISTEMA SELECCIONE MODO SISTEMA El modo Sistema puede ajustarse oprimiendo la tecla [SYS]
en el modo Duracin Normal. El modo Sistema se ajusta en esta secuencia:
APAGADOCALORFRIOAUTOAPAGADO Modo Sistema Modo CALOR Modo FRIO Modo AUTO Modo El sistema de calentamiento se activar si la temperatura ambiente es ms baja que la temperatura de ajuste. El sistema de enfriamiento se activar si la temperatura ambiente es ms baja que la temperatura de ajuste. El sistema de Calentamiento o Enfriamiento se activar segn el punto de ajuste de Calor y Fro. Elpunto de ajuste de Calor y el punto deajuste deFro debern estar separados por una banda muerta de 3C/5F. Los sistemas de Calentamiento y Enfriamiento APAGADO no se activarn a ninguna temperatura. SELECCIONE MODO VENTILADOR El modo Ventilador puede ajustarse oprimiendo la tecla [FAN]
en el modo Duracin Normal. El modo Ventilador se ajusta en esta secuencia:
VENTILADOR AUTOVENTILADOR ENCENDIDO VENTILADOR AUTO Modo Ventilador Ventilador El Ventilador se Encienda cuando el sistema auto de Calentamiento o Enfriamiento se encuentra Encendido. (Segn el ajuste HE/HG) Ventilador El ventilador se mantiene encendido encendido todo el tiempo. Ajuste HE/HG:
Funcionando en CALOR Funcionando en FRIO HG Ventilador Encendido Ventilador Encendido HE Ventilador Apagado Ventilador Encendido MEDICION DE TEMPERATURA Tome la lectura a cada intervalo de 10 segundos. Precisin hasta
+/-0.5C (+/-1F). Resolucin: 0.5C (1F); 0C a 39.5C (32F a 99F). Para temperaturas por encima de 39.5C (99F), aparecer --. Para temperaturas por debajo de 0C (32F), aparecer --. CONTROL DE TEMPERATURA Cuando el programa se encuentra encendido y se alcanza una hora de programa especfica, se utilizar la temperatura control especfica para determinar el control de temperatura. Puede anular la temperatura control oprimiendo [L/M] hasta alcanzar la temperatura de control deseada. Gama de control de temperatura:
Modo Sistema MODO CALOR Fahrenheit Celsio Control de Calor Punto de ajuste 41 a 95 5 a 35 MODO FRIO Control de Fro Punto de ajuste 41 a 95 5 a 35 MODO AUTO Control de Calor Punto de ajuste Control de Fro Punto de ajuste 41 a 90 46 a 95 5 a 32 8 a 35 La resolucin de control es 0.5C (1F). 1. Sistema ajustado en CALOR:
1. INTERVALO: +1/-0.5C (+2/-1F):
Calentador ENCENDIDO: Temperatura Real
<= Temperatura Control 0.5C (1F) Calentador APAGADO: Temperatura Real
>= Temperatura Control 1C (+2F) 2. Sistema ajustado en FRIO:
1. INTERVALO: +1/-0.5C (+2/-1F):
Enfriador ENCENDIDO: Temperatura Real
>= Temperatura Control 1C (+2F) Enfriador APAGADO: Temperatura Real
<= Temperatura Control 0.5C (+1F) 3. Sistema ajustado en AUTO:
El indicador del rotor comienza a girar cuando se satisfacen tanto la condicin Calor/Fro/Auto, como la condicin de retardo. El indicador del rotor permanece encendido y no girar hasta que finalice la condicin de retardo. El indicador del rotor desaparece cuando el sistema se encuentra apagado. El retardo para Calor Encendido y Fro Encendido tiene el propsito de prevenir ciclos cortos en el sistema. Ajuste de interruptor de retardo s/w en el Controlador Retardo Sin Retardo Sistema funcionando en CALOR 5-10 segs. 4-5 min. Sistema funcionando en FRIO 4-5 min. 4-5 min. DESHIELO (EL SISTEMA ESTA ESTABLECIDO EN CALOR/AUTO) Cuando la Temperatura Real est por debajo de 5C (41F) y hay suficiente tiempo de retardo, el CALENTADOR est siempre ENCENDIDO y el ENFRIADOR est siempre APAGADO, independientemente del ajuste de temperatura control actual. Indicador LCD DEFROST ENCENDIDO. DESHIELO (EL SISTEMA ESTA ESTABLECIDO EN CALOR/AUTO) Cuando la Temperatura Real est por encima de 35C (95F) y hay suficiente tiempo de retardo, el CALENTADOR est siempre APAGADO y el ENFRIADOR est siempre ENCENDIDO, independientemente del ajuste de temperatura control actual. COMUNICACION RF PARA CONFIGURAR CON EL RECEPTOR 1. 2. Asegrese que el controlador para termostato se encuentre Instale las bateras en el controlador para termostatos. en estado predeterminado (por ejemplo, SISTEMA est ajustado en APAGADO, VENTILADOR est ajustado en AUTO). Esto es para garantizar que el receptor reciba la direccin correcta del controlador para termostatos. 3. Aplique potencia al receptor RF, lleve el interruptor dip ON/OFF (ENCENDIDO/APAGADO) a la posicin ON
(ENCENDIDO). 4. Ajuste el VENTILADOR del termostato en ON (ENCENDIDO):
El receptor acepta el mensaje y guarda la identidad del controlador. Los LED SETUP (AJUSTE) y FAN (VENTILADOR) se encuen-
tran ENCENDIDOS. El termostato se encuentra ahora ajustado para enviarle seales al receptor. En cualquier momento, si nota que el receptor RF recibe interferencia de otros controladores inalmbricos para termostatos, oprima el interruptor dip SETUP (AJUSTE) del receptor a la posicin OFF (APAGADO). Luego cambie el cdigo de direcciones del controlador para termostatos seleccionando otros ajustes de los 9 interruptores dip ubica-
dos en la parte posterior del controlador. Luego restablzcalo y repita los pasos 2 al 4 para cada nuevo ajuste. 5. El ajuste ha finalizado. Ahora puede ajustar la tecla FAN
(VENTILADOR) y la tecla SYSTEM (SISTEMA) del termostato a las ubicaciones deseadas. El usuario puede seleccionar hasta 512 direcciones en caso de interferencia con otros controladores inalmbricos para termostatos. El indicador de transmisin permanece encendido cuando se est transmitiendo la seal RF. La seal RF se transmite durante 10 minutos para obtener la informacin actualizada. Actualice automticamente el estado del Sistema y Ventilador en el receptor cada 10 minutos a travs de la seal RF. No se podr alternar el rel en el lado del receptor a la posicin ON (ENCENDIDO) si no hay suficiente tiempo de retardo. OFF (APAGADO) G Y RHW RC AJUSTE OFF ON AUTO significa que el sistema puede alternarse automti-
camente entre CALOR y FRIO segn la temperatura control. En el modo Auto, la temperatura de ajuste de Fro debe ser ms alta que la temperatura de ajuste de Calor, con una diferencia de 3C/5F o ms, pero ste lmite no aplica al modo Calor y el modo Fro. 1. INTERVALO: +1/-0.5C (+2/-1F):
Calentador ENCENDIDO Automticamente:
Temperatura Real
<= Temperatura de Control de Calor 0.5C (+1F) Enfriador ENCENDIDO Automticamente:
Temperatura Real
>= Temperatura de Control de Fro 1C (+2F) Calentador y Enfriador apagados cuando la Temperatura Real se encuentra dentro de la zona de apagado (por ejemplo, la distancia mnimia entre los puntos de Ajuste de Calor y de Fro). Rel del Ventilador Figura 2 Rel de Fro Rel de Calor ON (ENCENDIDO) RC RH El Mdulo de Receptor RF brinda control de 24 VCA para equipo HVAC cuando se utiliza con un controlador inalmbrico para termostatos. Puede utilizarse con aplicaciones convencionales de zona nica 1H/1C. AVISO: Antes de restablecer el transmisor, asegrese que el interruptor dip ON/OFF (ENCENDIDO/APAGADO) est ajustado en OFF (APAGADO) en el receptor. Luego de restablecer el transmisor, el interruptor dip ON/OFF (ENCENDIDO/APAGADO) en el receptor est ajustado en ON (ENCENDIDO) y siga las instrucciones de configuracin del receptor. 1UHG7 DECLARACION DE LA FCC Este dispositivo cumple con la Seccin 15 de las Normas de la FCC. Su funcionamiento est sujeto a las siguientes dos condi-
ciones: (1) Este dispositivo no debe causar interferencia y (2) Este dispositivo debe aceptar toda interferencia recibida, incluida aqulla que puede causar un funcionamiento no deseado. Los cambios o modificaciones a esta unidad no aprobados expresamente por la parte responsable para el cumplimiento podran anular la autoridad del usuario conferida para utilizar este equipo. AVISO: Este equipo ha sido probado, y se consider que cumple con los lmites de los aparatos digitales de Clase B, de acuerdo con las especificaciones de la Parte 15 de las Reglas de la FCC. El objetivo de estos lmites es ofrecer proteccin razonable contra interferencias perjudiciales en una instalacin residencial. Este equipo genera, utiliza y puede radiar energa de radio-
frecuencia y, si no se instala y utiliza de acuerdo con estas instrucciones, puede generar interferencia perjudicial para las radiocomunicaciones. Sin embargo, no se garantiza que no se producir interferencia en una instalacin en particular. Si su equipo causa interferencia perjudicial para la recepcin de radio o televisin, que puede averiguar apagando y encendiendo el equipo, intente corregirla mediante uno o varios de los siguientes procedimientos:
Vuelva a orientar o cambie de lugar la antena receptora. Aumente la separacin entre el equipo y el receptor. Conecte el equipo a un tomacorriente en un circuito diferente al que est conectado el receptor. Consulte al distribuidor o a un tcnico experimentado de radio y televisin para solicitar asistencia. GARANTIA LIMITADA GARANTIA LIMITADA DE DAYTON POR UN AO. DAYTON ELECTRIC MFG. CO. (DAYTON) LE GARANTIZA AL USUARIO ORIGINAL QUE LOS MODELOS TRATADOS EN ESTE MANUAL DEL TERMOSTATO INALMBRICO PROGRAMABLE CON PANTALLA LCD DAYTON ESTAN LIBRES DE DEFECTOS EN LA MANO DE OBRA O EL MATERIAL, CUANDO SE LES SOMETE A USO NORMAL, POR UN AO A PARTIR DE LA FECHA DE COMPRA. CUALQUIER PARTE QUE SE HALLE DEFECTUOSA, YA SEA EN EL MATERIAL O EN LA MANO DE OBRA, Y SEA DEVUELTA (CON LOS COSTOS DE ENVIO PAGADOS POR ADELANTADO) A UN CENTRO DE SERVICIO AUTORIZADO DESIGNADO POR DAYTON, SERA REPARADA O REEMPLAZADA (NO EXISTE OTRA POSIBILIDAD) SEGUN LO DETERMINE DAYTON. PARA OBTENER INFORMACION SOBRE LOS PROCEDIMIENTOS DE RECLAMO CUBIERTOS EN LA GARANTIA LIMITADA, VEA LA SECCION ATENCION OPORTUNA QUE APARECE MAS ADELANTE. ESTA GARANTIA LIMITADA CONFIERE AL COMPRADOR DERECHOS LEGALES ESPECIFICOS QUE VARIAN DE JURISDICCION A JURISDICCION. LIMITES DE RESPONSABILIDAD. EN LA MEDIDA EN QUE LAS LEYES APLICABLES LO PERMITAN, LA RESPONSABILIDAD DE DAYTON POR LOS DAOS EMERGENTES O INCIDENTALES ESTA EXPRESAMENTE EXCLUIDA. LA RESPONSABILIDAD DE DAYTON EXPRESAMENTE ESTA LIMITADA Y NO PUEDE EXCEDER EL PRECIO DE COMPRA PAGADO POR EL ARTICULO. EXCLUSION DE RESPONSABILIDAD DE LA GARANTIA. SE HAN HECHO ESFUERZOS DILIGENTES PARA PROPORCIONAR DILIGENTEMENTE PARA PROPORCIONAR INFORMACION E ILUSTRACIONES APROPIADAS SOBRE EL PRODUCTO EN ESTE MANUAL; SIN EMBARGO, ESTA INFORMACION Y LAS ILUSTRACIONES TIENEN COMO UNICO PROPOSITO LA IDENTIFICACION DEL PRODUCTO Y NO EXPRESAN NI IMPLICAN GARANTIA DE QUE LOS PRODUCTOS SEAN VENDIBLES O ADECUADOS PARA UN PROPOSITO EN PARTICULAR NI QUE SE AJUSTAN NECESARIAMENTE A LAS ILUSTRACIONES O DESCRIPCIONES. CON EXCEPCION DE LO QUE SE ESTABLECE A CONTINUACION, DAYTON NO HACE NI AUTORIZA NINGUNA GARANTIA O AFIRMACION DE HECHO, EXPRESA O IMPLICITA, QUE NO SEA ESTIPULADA EN LA GARANTIA LIMITADA ANTERIOR. Consejo Tcnico y Recomendaciones, Exclusiones de Responsabilidad. A pesar de las prcticas, negociaciones o usos comerciales realizados previa-
mente, las ventas no debern incluir el suministro de consejo tcnico o asistencia o diseo del sistema. Dayton no asume ninguna obligacin o responsabilidad por recomendaciones, opiniones o consejos no autorizados sobre la eleccin, instalacin o uso de los productos. Adaptacin del Producto. Muchas jurisdicciones tienen cdigos o regula-
ciones que rigen la venta, la construccin, la instalacin y/o el uso de produc-
tos para ciertos propsitos que pueden variar con respecto a los aplicables a las zonas vecinas. Si bien se trata de que los productos Dayton cumplan con dichos cdigos, no se puede garantizar su conformidad y no se puede hacer responsable por la forma en que se instale o use su producto. Antes de comprar y usar el producto, revise su aplicacin y todos los cdigos y regulaciones nacionales y locales aplicables y asegrese de que el producto, la instalacin y el uso los cumplan. Ciertos aspectos de limitacin de responsabilidad no se aplican a productos al consumidor; es decir (a) algunas jurisdicciones no permiten la exclusin ni limitacin de daos incidentales o consecuentes, de modo que las limitaciones o exclusiones anteriores quizs no apliquen en su caso; (b) asimismo, algunas jurisdicciones no permiten limitar el plazo de una garanta implcita, por lo tanto, la limitacin anterior quizs no aplique en su caso; y (c) por ley, mientras la Garanta Limitada est vigente no podrn excluirse ni limitarse en modo alguno ninguna garanta implcita de comercializacin o de idoneidad para un propsito en particular aplicables a los productos al consumidor adquiridos por ste. Atencin Oportuna. Se har un esfuerzo de buena fe para corregir puntualmente, o hacer otros ajustes, con respecto a cualquier producto que resulte defectuoso dentro de los trminos de esta garanta limitada. En el caso de que encuentre un producto defectuoso y que est cubierto dentro de los lmites de esta garanta haga el favor de escribir primero, o llame, al distribuidor a quien le compr el producto. El distribuidor le dar las instrucciones adicionales. Si no puede resolver el problema en forma satisfactoria, escriba a Dayton a la direccin a continuacin, dando el nombre del distribuidor, su direccin, la fecha y el nmero de la factura del distribuidor y describa la naturaleza del defecto. La propiedad del artculo y el riesgo de prdida pasan al comprador en el momento de la entrega del artculo a la compaa de transporte. Si el producto se daa durante el transporte, debe presentar su reclamo a la compaa transportista. Fabricado para Dayton Electric Mfg. Co., 5959 W. Howard St., Niles, Illinois 60714-4014 EE.UU. Servicio de asistencia tcnica: 888-361-8649
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2007-12-03 | 433.8 ~ 433.8 | DSC - Part 15 Security/Remote Control Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2007-12-03
|
||||
1 | Applicant's complete, legal business name |
World Excel Company Ltd
|
||||
1 | FCC Registration Number (FRN) |
0017095209
|
||||
1 | Physical Address |
RM B, 26/F, Capital Trade Centre, 62 Tsun Yip Stre
|
||||
1 |
Hong Kong
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
t******@intertek.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
VSM
|
||||
1 | Equipment Product Code |
16950235000001
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
K**** A******
|
||||
1 | Title |
Engineering Manager
|
||||
1 | Telephone Number |
852-2******** Extension:
|
||||
1 | Fax Number |
852-2********
|
||||
1 |
k******@worldexcel.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Intertek Testing Services Hong Kong Ltd.
|
||||
1 | Name |
B****** C********
|
||||
1 | Physical Address |
2/F., Garment Centre
|
||||
1 |
Kowloon, N/A
|
|||||
1 |
Hong Kong
|
|||||
1 | Telephone Number |
(852)********
|
||||
1 | Fax Number |
(852)********
|
||||
1 |
b******@intertek.com
|
|||||
app s | Non Technical Contact | |||||
1 | Firm Name |
Intertek Testing Services Hong Kong Ltd.
|
||||
1 | Name |
B****** C****
|
||||
1 | Physical Address |
2/F., Garment Centre
|
||||
1 |
Kowloon, N/A
|
|||||
1 |
Hong Kong
|
|||||
1 | Telephone Number |
(852)********
|
||||
1 | Fax Number |
(852)********
|
||||
1 |
b******@intertek.com
|
|||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DSC - Part 15 Security/Remote Control Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | RF Wireless Thermostat Transmitter (433.8MHz Tx) | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Intertek Testing Services Hong Kong
|
||||
1 | Name |
B**** C******
|
||||
1 | Telephone Number |
852-2********
|
||||
1 | Fax Number |
852-2********
|
||||
1 |
b******@intertek.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15.231(e) | 433.80000000 | 433.80000000 |