TReX User Manual v2.14 Firmware WTE TReX TELEMETRY, DATA AND PAGING I/O TRANSCEIVER User Manual WTE Limited, 2018 Christchurch New Zealand Page 1 of 158 Table of Contents Introduction...............................................5 TReX Features........................................5 TReX Versions........................................6 Safety Information.....................................8 Operation..................................................12 Buttons......................................................13 MENU/BACK:.....................................13 UP:........................................................13 DOWN:.................................................13 RIGHT:.................................................13 ENTER:................................................13 Main Screens............................................14 IO Screens.............................................15 TX Screens............................................17 RX Screens...........................................19 Site Configuration Tools..........................21 Spectrum Analyser................................21 Demodulated Signal Viewer.................22 Two-Way Paging......................................23 Configuration Methods...........................24 Front Panel Menu Configuration..........25 Web Browser Configuration.................27 Serial Command Configuration............29 MENU Configuration..............................31 SYSTEM Menu....................................33 TEST Sub Menu...................................36 FACTORY Sub Menu...........................37 TIME Sub Menu...................................38 SPECTRUM Menu...............................39 RX Menu...............................................41 FILTERS..........................................43 Protocol Menu.......................................46 TCP-IP Menu........................................47 Telemetry Menu....................................49 SERIAL LINK Menu............................51 STORE FWD Menu..............................52 Inputs Menu..........................................53 ADC CAL Sub-Menu...........................54 Input Config Sub-Menu...................56 Outputs Menu.......................................59 Output Config Sub-Menu.................61 DAC CAL Sub-Menu.......................62 Serial Command Configuration.............64 Main Commands...................................64
*REBOOT........................................64
*CONFIG.........................................64 TReX User Manual v2.14 Firmware
*SAVE..............................................64
*LIST...............................................64
*DEFAULTS....................................64
*RSSI...............................................65
*USERPASS....................................65
*IO....................................................65
*TEMP.............................................66
*PWR...............................................66
*VER................................................66
*BYPASS.........................................66
*LAB................................................67 Transmit Commands.............................68
*TX_FREQ......................................68
*TX_PROTO...................................68
*TX_BAUD.....................................68
*TX_MODE.....................................68
*TX_LEVEL....................................69
*TX_CAP.........................................69
*TX_PERIODIC..............................69
*TX_PREAMBLE...........................69
*TX_LEAD......................................70 Receive Commands..............................71
*RX_ENABLE................................71
*RX_FREQ......................................71
*RX_BAUD.....................................71
*RX_PROTO...................................71
*RX_MODE....................................71
*RX_RANGE..................................72
*RX_BUSY......................................72 Store Forward Commands....................73
*STORE_FWD................................73 Input Commands...................................74
*IN_CONFIG_L..............................74
*IN_CONFIG_H..............................74
*IN_MSG_L....................................75
*IN_MSG_H....................................75
*IN_ANALOG.................................75 Output Commands................................77
*OUT_CONFIG...............................77
*UNIT_ID........................................77 System Commands...............................78
*TREX_LANG................................78
*TREX_BACKLIGHT....................78
*TREX_SOUND..............................78
*TREX_RS232_BAUD...................78
*TREX_RS422_BAUD...................79 WTE Limited, 2018 Christchurch New Zealand Page 2 of 158
*TREX_ALERT_OUT....................79
*TREX_ALERT...............................79
*TREX_FILTERS............................79
*TREX_TELEMETRY....................80
*TREX_SCREEN............................80
*TREX_PIN.....................................80
*TREX_AN_CAL............................81
*TREX_MISMATCH......................81 TCP-IP Commands...............................83
*IP_ENABLE..................................83
*IP_HOST........................................83
*IP_ADD.........................................83
*IP_PORT........................................83
*IP_MASK.......................................84
*IP_GATE........................................84
*IP_DNS..........................................84
*IP_MAC.........................................84 Protocols...................................................85 WT Protocol..........................................85 Variable Content Macros..................88 Modbus.................................................89 Modbus RTU....................................89 Modbus TCP....................................89 Function Codes.................................89 Modbus Mapping Table...................90 Custom Protocol...................................92 Custom Protocol Response..............95 Custom Protocol Output...................95 RAW Protocol.......................................97 SCADA Support.......................................99 Terminology..........................................99 SCADA System Single TReX Configuration......................................101 Unit Configuration.........................102 SCADA System Multiple TReX Configuration......................................103 Units Configuration........................104 Viewing Multiple TReX Unit IO on the MASTER Unit....................................106 SCADA Communication Between MASTER and SLAVE........................107 IO Mirror Operation.............................108 Input Handling.......................................110 Output Handling....................................112 WTE Output Control Protocol.............113 Introduction.........................................113 Digital Output Format.........................113 TReX User Manual v2.14 Firmware Examples:.......................................113 Analog & Digital Output Format........114 WTE Ack and Confirm Protocol..........116 Introduction.........................................116 Store Forward Operation.....................120 Installation..............................................121 Cables Supplied..................................121 Connecting to the TReX.....................122 Connector Pin descriptions.................123 RHS (Right Panel)..........................123 LHS (Left Panel)............................125 Input Output Hardware Connection...127 Inputs..................................................127 Outputs................................................128 Serial Connections.................................129 RS-232................................................129 RS-422/RS-485...................................130 Point To Point Connection.............131 Multi-Point Connection..................131 2 Wire Connection..........................132 Bus Terminating Resistor...............132 RF Connections......................................134 Power Connections................................135 Ethernet Interface..................................136 TReX Firmware Upgrade.....................137 Firmware Upgrade Utility...................137 Upgrade Process.................................138 Physical Dimensions..............................139 Mounting Hardware..............................140 DIN Rail..............................................140 Mounting Channels.............................141 TOP Mount.........................................141 SIDE Mount........................................142 Bottom Mount.....................................143 Mount Bolts Dimensions....................144 Top and Bottom Drilling Template.....145 Side Drilling Template........................146 Omni or Directional Antenna...............147 Omni antenna......................................147 Directional antenna.............................147 Antenna Elevation.................................148 Disclaimer...............................................150 Manufacturing marking and labels.....151 Maintenance...........................................151 Product End Of Life..............................152 Product Warranty..................................153 Abbreviations and Glossary.................154 WTE Limited, 2018 Christchurch New Zealand Page 3 of 158 Specifications..........................................155 TReX User Manual v2.14 Firmware WTE Limited, 2018 Christchurch New Zealand Page 4 of 158 TReX User Manual v2.14 Firmware Introduction Thank you for choosing the TReX. The TReX is an Ethernet, Serial (RS232 plus RS485/RS422) and USB capable transceiver for data, paging (one and two-way) and general telemetry use. The TReX can be configured through; a simple integrated display and keypad, serial commands, TCP, USB or via a web browser. The TReX is suitable for commercial, industrial and remotely managed control/monitoring applications. Use the TReX when high reliability, long range and high speed control or messaging is required . The TReX can be used to:
Transmit and receive paging messages. Connect to third party SCADA control and monitoring systems using Modbus protocols. Log messages to internal memory to meet auditing requirements. Mirror analog and digital inputs to a remote unit. Report system and installation errors, such as loss of communications, and battery Inspect potential site interference using the integrated spectrum analyser. states. Detect antenna faults during normal operation. Transmit and receive serial and telemetry data at high data rates. Act as a repeater for forwarding telemetry and paging messages in poor coverage areas. TReX Features Up to 4W power output. DIN rail mountable aluminium enclosure that also allows simple mounting from top, bottom or sides. Data transmit rates from 512 baud to 32K baud. Supported channel spacing of 25kHz, 12.5kHz and 6.25kHz. Support for two-way paging. Provides receipt of delivery and optionally receipt for accepted jobs. Supports 512, 1200, 2400, 4800 and 9600 baud POCSAG paging messages. Receives 1600 baud 2 level FLEX paging messages. Modbus RTU and TCP support for easy SCADA system integration. Two 0-10V/4-20mA analog outputs Two 0-10V analog inputs. Paging store and forward repeater operation with configurable duplicate reject. 8 digital inputs and outputs. Integrated spectrum analyser (optional). WTE Limited, 2018 Christchurch New Zealand Page 5 of 158 Simple to configure back to back mirroring and monitoring of analog and digital IO. Extended SCADA system expansion supporting up to 11 wirelessly connected units per system (optional). TReX User Manual v2.14 Firmware Optional logging to SD card of all received and transmitted messages. Graphics display shows all radio activity including I/O state. Multi language support (English and Spanish) and additional languages available on request. Fully configurable via front panel without the need for an external PC connection. Configurable via serial port, direct USB connection or Ethernet. RS232, RS422 and RS485 (both 4 and 2 wire) support. USB connection allows downloading of message logs or direct access to configuration files. Configured inputs can be programmed to output messages when triggered. Configured digital and analog outputs can be controlled via received messages. Any output can be assigned to indicate:
Channel busy. The channel busy output level is configurable. Alert on filtered match of message payload. Comms link fail. Antenna fault. Low output power. High temperature. Periodic message support to ensure radio link integrity. Low battery messaging. Inclusion of the WTE CUSTOM protocol, that allows support of many existing paging protocols without the need for new firmware. Support for additional protocols upon request and negotiation. Firmware upgradable. High stability oscillator ensuring a maximum of 80Hz drift (at 160MHz) over the entire specified temperature range. Antenna mismatch detection capability. High sensitivity receiver. Internal real time clock. Long-life design uses no moving or electromechanical parts. No limited life components such as electrolytic capacitors. TReX Versions TReX-460, TReX-461:
Telemetry, I/O and Messaging Transceiver WTE Limited, 2018 Christchurch New Zealand Page 6 of 158 TReX User Manual v2.14 Firmware TReX-460-P, TReX-461-P:
Ethernet Paging I/O Transceiver. TReX-460-R, TReX-461-R:
Ethernet Paging I/O Receiver (no transmit capability) The TReX can be supplied to operate within these bands:
TReX-16x (142MHz to 175MHz) TReX-46x (421MHz to 480MHz). Variants TReX-460 (USA), TReX-461 (Europe, AU and NZ). WTE Limited, 2018 Christchurch New Zealand Page 7 of 158 TReX User Manual v2.14 Firmware Safety Information Read these instructions carefully, and look at the equipment to become familiar with the device before trying to install, operate, or maintain it. The following special messages may appear throughout this documentation or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure. This is the safety alert symbol. It is used to alert you to a potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
!
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
!WARNING CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury
!CAUTION NOTICE is used to address practices not related to physical injury. NOTICE WTE Limited, 2018 Christchurch New Zealand Page 8 of 158 TReX User Manual v2.14 Firmware
!WARNING LOSS OF CONTROL The designer of any control scheme must consider the potential failure modes of control paths and, for certain critical control functions, provide a means to achieve a safe state during and after a path failure. Examples of critical control functions are emergency stop and over travel stop. Separate or redundant control paths must be provided for critical control functions. System control paths may include communication links. Consideration must be given to the implications of anticipated transmission delays or failures of the link. Failure to follow these instructions can result in death or serious injury THIS EQUIPMENT IS NOT INTENDED FOR MAINS VOLTAGES
!WARNING TReX was NOT designed to operate and/or be connected directly to live main voltages. The TReX must be connected to a certified, suitably rated low voltage DC supply. Failure to follow these instructions can result in death or serious injury WTE Limited, 2018 Christchurch New Zealand Page 9 of 158 TReX User Manual v2.14 Firmware HAZARD OF EQUIPMENT DAMAGE NOTICE This product is not chemical resistant, detergent, alcohol, aerosol sprays, and/or petroleum products may damage the front panel. Clean using a soft cloth moistened in water. The radio can be damaged if there is any potential difference between the chassis-ground, Serial signal ground, power (-) input, or antenna coaxial shield. Before connecting any wiring, ensure that all components are earthed to a common ground point. The antenna port will be damaged if signals greater than 13 dBm are injected/received. Do not connect any other transmitter to the RF connector or share the antenna with any other device. Extreme Heat or High temperatures can damage TReX components. DO NOT expose or operate the unit in extreme heat (above 70 degrees Celsius) or leave in direct sunlight or any other UV source. Although this product is designed to be rugged, it will not survive excessive shock or vibration abuse. The TReX is intended to be mounted permanently either in a land based location or in a vehicle. When fitting in a vehicle, vibration damping mounts may be required. The TReX IP rating is IP-51. TReX is not waterproof or dustproof. DO NOT directly expose to rain or use in a condensation forming environment. When antennas are co-located on a community (shared) site the correct site engineering must be performed to ensure that RF exposure limits are met. CARE REQUIRED WHEN TRANSPORTING NOTICE Safety and care must be taken when transporting, handling, installing and/or replacing radio equipment. Packaging should be adequate to ensure connectors are not damaged Store and handle the radio equipment in dry, clean safe environment Handle the equipment with care Avoid intrusion of any object/material into the radio case Care when stacking TReX boxes must be taken to not damage part of the radio, such as connectors. NOTICE introduction of foreign object into the TReX radio enclosure will void warranty. WTE Limited, 2018 Christchurch New Zealand Page 10 of 158 TReX User Manual v2.14 Firmware FCC NOTICE This device complies with Part 15.247 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference and 2. This device must accept any interference received, including interference that may cause undesired operation. This device must be operated as supplied by the equipment supplier. Any changes or modifications made to the device without the written consent of the equipment supplier may void the users authority to operate the device. End user products that have this device embedded must be installed by experienced radio and antenna personnel, or supplied with non-standard antenna connectors, and antennas available from vendors specified by the equipment supplier. Please contact the equipment supplier for end user antenna and connector recommendations. Exposure to RF energy is an important safety consideration. The FCC has adopted a safety standard for human exposure to radio frequency electromagnetic energy emitted by FCC regulated equipment as a result of its actions in General Docket 79-144 on March 13, 1996. This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 43cm between the radiator and any part of your body. NOTICE This symbol on the product or its packaging indicates that this product must not be disposed of with other waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help conserve natural resources and help ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, contact the dealer from whom you originally purchased the product. WTE Limited, 2018 Christchurch New Zealand Page 11 of 158 TReX User Manual v2.14 Firmware Operation Once a 13.8V source has been connected to the power connector the TReX start-up status is displayed on the LCD. When the TReX is operating normally, the two green status LEDs flash briefly once every second. When decoding messages, the A green LED is held on for approximately one second. The C red LED is held on for the duration of a transmission, while processing TCP data, Modbus protocol commands and decoding received messages. Both the C and D red LEDs light while starting. On start-up under normal operation there is a message sent out the serial port. The message indicates the firmware revision, serial number other software related information. After finishing the start-up procedure and loading of configuration settings the TReX enters its receive and decode mode of operation. The TReX now waits for commands to be entered serially for processing or inputs to be triggered. These may be either protocol messages to be processed or commands related to the configuration of the device. Serial messages may arrive on any serial port, or may also arrive through a TCP connection. When messages are received and decoded, they are immediately sent out the serial port in the format of the configured protocol in use. Messages are transmitted as per the input configuration when inputs change state. Please refer to Input Output Hardware Connection or Input Handling sections on this manual for further information. The TReX outputs are driven high or low, or for a particular period of time depending on configuration. The outputs are controlled via the WTE Output Control Protocol message received and decoded. Each output can be configured to operate under various error states
(Refer to Outputs). WTE Limited, 2018 Christchurch New Zealand Page 12 of 158 Buttons TReX User Manual v2.14 Firmware MENU/BACK:
When on the MAIN SCREENS used to enter the MENU. When inside the MENU, used to return back one level from within the MENU, until returning back to the MAIN SCREENS. UP:
When on the MAIN SCREENS used to cycle between sub-screens. When in the MENU used to navigate or alter selected configuration items. DOWN:
When on file related screens of the MAIN SCREENS shifts between entries. When in the MENU used to navigate or alter selected configuration items. RIGHT:
When on the MAIN SCREENS used to cycle between main screen. Within the MENU used to enter sub MENU items or select items for configuration. ENTER:
Used to select file related items from within the MAIN SCREENS. WTE Limited, 2018 Christchurch New Zealand Page 13 of 158 TReX User Manual v2.14 Firmware Main Screens The TReX top icon bar provides information about the display screen and operating status. The far right text indicates the selected main screen. This is either IO (inputs and outputs), TX (transmit) or RX (receive). The far left icon indicates system voltage as a proportion of the configured high and low battery levels (MENU->INPUTS->BATT HIGH/LOW V). The X icon is visible when no messages have been received for 2 minutes and on start-up. The time in the middle is the current RTC time (MENU->SYSTEM->TIME). The S letter indicates that the master or slave SCADA telemetry modes are in operation. The M letter, when present indicates that a Modbus telemetry request packet has been processed within the last 2 seconds. The Incoming down arrow indicates that the TReX is receiving (absent when RX is DISABLED). The Outgoing up arrow indicates that the TReX is transmitting (if a transmitter enabled TReX). The Icon T below indicates the TReX has been configured for telemetry stand-
alone Back-to-Back Mirror Mode. The back to back arrows indicate the unit is operating in Serial Link Telemetry mode. WTE Limited, 2018 Christchurch New Zealand Page 14 of 158 TReX User Manual v2.14 Firmware IO Screens Screens that relate to inputs and outputs. IO (1):
All input and output states. Each IO highlighted state changes if the IO level is HIGH or LOW. There is a small line above each input or output if HIGH, and a line below if LOW. All ADCs (analog inputs) and DACs (analog outputs) show a bar graph as a proportion of full scale and display a raw count from 0-1023. When scaling has been applied to an analog output, the DAC value shown is the unscaled value. In the middle, shown in larger text is 01. The number01 in this case is the telemetry UNIT ID. When TELEMETRY->MODE is configured to SCADA_MASTER a small down arrow may be visible if the TELEMETRY->REMOTES have been configured to be more than 0. Pressing the down arrow (when configured as a SCADA_MASTER) allows the UNIT ID to be cycled to view the IO of each remote slave in the system allowing a possible system of up to 88 digital IO, 22 ADCs and 22 DACs to be viewed. Next to the UNIT ID is the smaller number 123. Each TReX resets this number to the LINK FAIL TIME each time a message is decoded. This link count reduces, and if reaches 0, the link fail output can be operated. SCADA_MASTER TReX units allow the link count to be viewed for all remote TReX SCADA_SLAVE units. WTE Limited, 2018 Christchurch New Zealand Page 15 of 158 TReX User Manual v2.14 Firmware IO (2):
System voltage, current and internal operating temperature. RF is the temperature read directly next to the RF power stage and will be higher than than the DIG board temperature while the TReX is transmitting (not applicable for receiver only TReX units). Temperatures of the RF power stage may reach 100 degrees Celsius under normal long term operation. These temperatures are not the ambient temperature. The case of the TReX will NOT reach these temperatures. As with the previous IO screen, systems voltages and temperatures of all SCADA_SLAVE TReX units (up to 10 SLAVE units) can be viewed by pressing the down button if the TReX is configured to be a SCADA_MASTER. WTE Limited, 2018 Christchurch New Zealand Page 16 of 158 TReX User Manual v2.14 Firmware TX Screens Screens that relate to messages transmitted. TX (1):
Last message transmitted. Includes the time the message was transmitted, message RIC (radio identifying code/CAP Code) and level (0-3). To the right the modulation type and rate is displayed also with the transmit frequency. TX (2):
List of all time-stamped messages retrieved from internal storage. Most recent message displayed at top. Next sub-screen can only be selected when top entry is displayed. Note that messages are only available here when TX logging has been enabled (MENU->TX->MSG LOG). When an entry is selected pressing the UP/DOWN buttons, pressing the ENTER button displays the entire message. WTE Limited, 2018 Christchurch New Zealand Page 17 of 158 TReX User Manual v2.14 Firmware TX (3):
Displays the last transmitted message in large font. If the message exceeds the screen size, the DOWN button allows scrolling. TX (4):
A TX power bar graph is displayed as a proportion of full power during a message transmission. Above the power bar is the text POWER 2W (168). 2W relates to the power setting in use. In brackets is the power amplifier DAC setting which is for factory use only. The POWER ADC count is used to indicate forward power. RF TEMP relates to the RF amplifier temperature (not ambient) in degrees Celsius. VOLTS is the supply voltage and AMPS is the total supply current. WTE Limited, 2018 Christchurch New Zealand Page 18 of 158 TReX User Manual v2.14 Firmware RX Screens Screens that relate to messages received. Note, when messages are received, additional icons may be displayed in the top bar. The second left icon changes from the X icon to the satellite icon when a message has been received. This indicates that the receiver is operational. When the BELL icon is displayed with a following number, this means that system ALERTS are enabled. See ALERTS for ALERT configuration and operation. RX (1):
Basic summary of last received message. If the message is too large to fit on the screen the DOWN arrow will be visible in the title bar. Pressing the DOWN button will now scroll through the rest of the message. RX (2):
List of all time-stamped received messages retrieved from internal storage. Most recent message displayed at top. Next sub-screen can only be selected when top entry is displayed. Note that messages are only available here when RX logging has been enabled (MENU->RX-
>MSG LOG). Messages starting with * are messages that met the ALERT filter requirements, and were eligible to operate the ALERT output when logged. WTE Limited, 2018 Christchurch New Zealand Page 19 of 158 RX (3):
Displays the last received message in large font. If the message exceeds the screen size, the DOWN button allows scrolling. TReX User Manual v2.14 Firmware RX (4):
Displays the signal strength of the configured channel in real time. Displays signal strength from -128dBm to 0dBm. WTE Limited, 2018 Christchurch New Zealand Page 20 of 158 TReX User Manual v2.14 Firmware Site Configuration Tools The TReX includes tools to ensure suitability for use at the current location and quality of the installation. Spectrum Analyser The optional spectrum analyser is a very simple to use tool that provides a span of either 3MHz, 120kHz or 24kHz around a configured test frequency. The receive bandwidth down to 500Hz is suitable for inspection of potentially interfering adjacent channel signals. The analyser can display signals as low as -125dBm making and is suitable for site inspection. This is an optional feature that requires a feature key to be purchased. WTE Limited, 2018 Christchurch New Zealand Page 21 of 158 TReX User Manual v2.14 Firmware Demodulated Signal Viewer The demodulated signal viewer allows inspection of raw demodulated data and the recovered clock from that data. This is useful for viewing channel activity. This facility is available for 2 level modulation modes of operation. 4 level modulation modes will display as straight lines. WTE Limited, 2018 Christchurch New Zealand Page 22 of 158 Two-Way Paging TReX User Manual v2.14 Firmware The TReX supports two-way paging. The TReX can return responses via serial or TCP connections. Transmitter capable TReX units can additionally respond at high power across the air. Not only can acknowledgements be returned from the TReX, but confirmation of job acceptance receipts can be returned. This means that messages can be sent to single or multiple TReX units and clear details can be returned to notify if a message has been read or an action is being performed. Example:
An emergency dispatch system may send a paging message to a group of ambulances for attendance at an emergency. The message will be displayed on a TReX unit within the ambulance with prompt to attend if possible. Accepting the job can be performed with a simple keypress that will send receipt to the dispatch system that the vehicle is on-route. See WTE Ack and Confirm Protocol for usage details. With a single keypress, key messages can be responded to. Details of the responder are returned and logged. WTE Limited, 2018 Christchurch New Zealand Page 23 of 158 TReX User Manual v2.14 Firmware Configuration Methods There are several methods to configure the TReX unit, such as:
Directly from the front panel Via a web browser Via Serial terminal over the RS232, RS422 and or RS485. Via a TCP terminal (either client or server). USB connection and editing of the WTE_CONF.INI configuration file. WTE Limited, 2018 Christchurch New Zealand Page 24 of 158 TReX User Manual v2.14 Firmware Front Panel Menu Configuration All typical configuration items are accessible and configurable via the on-board menu system. This includes the ability to configure input messages. Through the use of the menu system the TReX is able to be set up and configured without any PC connection. To enter the menu, press the MENU button. The top line icon bar shows when the DOWN button can be used when the DOWN arrow is visible. When scrolling down and the DOWN arrow disappears, then the end of the menu section has been reached. The UP arrow will be visible when navigation in the up direction is permissible. The RIGHT arrow indicates that the RIGHT button can be pressed to enter a MENU category when highlighted. Pressing the MENU button again moves back one level, until the top is reached, and then the TReX leaves the MENU mode. If any change has been made, changes will only be written to internal storage when leaving the MENU mode. WTE Limited, 2018 Christchurch New Zealand Page 25 of 158 TReX User Manual v2.14 Firmware To edit any field, first move to the item, press RIGHT to select the field. Once highlighted, the UP/DOWN arrows change the field. On completion, pressing RIGHT again will deselect the field. Some fields are text that can be edited. There is a built-in text editor. Fields that are edited by the text editor are presented with the title EDIT TEXT. Each character can be selected by pressing the RIGHT button. The selected character is inverted. Pressing the UP/DOWN buttons allows the character to be changed to any printable character. The BACK arrow indicates the end of the text. This arrow is not part of the actual text but present as a marker. To make the text longer, highlight the BACK arrow and change the character using the UP/DOWN buttons. To make the text shorter or to delete a character, highlight the BACK arrow and press the ENTER button. Press the BACK button to exit the editor. WTE Limited, 2018 Christchurch New Zealand Page 26 of 158 TReX User Manual v2.14 Firmware Web Browser Configuration For web browser configuration to be possible (using browsers that support SVG such as Chrome, Firefox etc.), the Ethernet/IP must be ENABLED via the menu (ENABLED by default). This is located in SYSTEM->IP. In this menu section network parameters can be configured such as the IP, Mask and gateway. Only a single connection to the TReX should be allowed. Multiple connections will result in impaired responsiveness. WTE Limited, 2018 Christchurch New Zealand Page 27 of 158 TReX User Manual v2.14 Firmware After the unit has been enabled to be use over the web, a web browser address matching the configured IP should be used. e.g. http://192.168.1.20 This IP address is shown as a pop-up each time the TReX starts up. Using the web browser the TReX can be remotely configured. When moving to a text field, the text box at the bottom of the browser is automatically loaded. Changes can now be made and committed by pressing the SEND button. This text box can also be used to transmit messages for a configured protocol. WTE Limited, 2018 Christchurch New Zealand Page 28 of 158 TReX User Manual v2.14 Firmware Serial Command Configuration Parameters can be changed using any common serial terminal (available on request if required) program using the RS232 or RS422/485 ports. Start-up baud rate is determined by the baud rate as configured through the MENU. All configuration commands always start with the asterisk * character. All messages that do not start with the * character are processed by the protocol decoder. All messages are terminated by a Carriage Return character, shown in this manual as <CR>
All commands that accept a value, can have that value read back by using the ? suffix. Typical usage:
*RX_FREQ?
Typical response:
*RX_FREQ=160000000 There are some commands that support multiple entries (such as the same command but for different ranges). In this case the question mark can be followed by the parameter to be interrogated. E.g.
*RX_RANGE?<CR>
Returns (lists all ranges)
*RX_RANGE=1:8,2000000
*RX_RANGE=2:0,0
*RX_RANGE=3:0,0
*RX_RANGE=4:0,0
*RX_RANGE=5:0,0
*RX_RANGE=6:0,0
*RX_RANGE=7:0,0
*RX_RANGE=8:0,0 To find the first range only:
Usage:
*RX_RANGE?1<CR>
Response:
*RX_RANGE=1:8,2000000 In order for any configuration changes made via serial to be saved the command *SAVE<CR>
must be sent to the TReX before removing power or restarting. Note: Although most configuration changes are applied immediately, it is a good practice to WTE Limited, 2018 Christchurch New Zealand Page 29 of 158 restart the unit after changing configuration. This can be achieved by removing power to the unit or sending the *REBOOT<CR> command. TReX User Manual v2.14 Firmware WTE Limited, 2018 Christchurch New Zealand Page 30 of 158 MENU Configuration TReX User Manual v2.14 Firmware SYSTEM Configures language, backlight, time, unit ID, sound, baud rates, factory test, main operating screens and menu lockout. TX Transmitter configuration items. Includes frequency, baud rates and logging settings. RX Receiver configuration items. Includes frequency, baud rates and logging settings. SPECTRUM Configures and allows access to the spectrum analyser. PROTOCOL Control of the formatting in and out of the TReX for incoming and outgoing messages. TCP-IP Control of all aspects of internet connectivity. Allows remote configuration and operation through the use of the Chrome or Firefox web browser, TCP client or TCP server. TELEMETRY WTE Limited, 2018 Christchurch New Zealand Page 31 of 158 TReX User Manual v2.14 Firmware Determines if operation is on a controlled protocol basis, or autonomously operating input states to a remote TReX device. STORE FWD Configuration of the paging store and forward repeater operation including duplicate reject. INPUTS Configuration of all inputs. OUTPUTS Configuration of all outputs. Also responsible for assigning of alerting functions to any output. WTE Limited, 2018 Christchurch New Zealand Page 32 of 158 SYSTEM Menu TReX User Manual v2.14 Firmware LANGUAGE Items ENGLISH plus others can be selected. To incorporate specific language support please contact WTE Limited directly. BACKLIGHT The backlight setting is how long in seconds the backlight is lit after each key press and also when a message is received. Setting to 0 disables the backlight completely. TIME Sets the internal clock. WTE Limited, 2018 Christchurch New Zealand Page 33 of 158 TReX User Manual v2.14 Firmware ID This is the unit ID that is used by the WTE output control protocol. This can be any number of alpha numeric description. e.g. 01 or Unit-A SOUND Allows control of system sounds that may be heard on an ALERT and also key beeps. Items ON and OFF can be selected. RS232 BAUD Allows configuration of the RS232 port baud rate. All settings are N:8:1. Available rates are:
2400, 4800, 9600, 38400, 57600 and 115200. Note: that for the most efficient transmission, the serial baud rate should be higher than the transmit over the air baud rate. RS422 BAUD Allows configuration of the RS422 port baud rate. All settings are N:8:1. Available rates are:
2400, 4800, 9600, 38400, 57600 and 115200 Note: that for the most efficient transmission, the serial baud rate should be higher than the transmit over the air baud rate. MAIN SCREEN This allows any page on any main screen to be set as the default main screen. This results in this screen being the screen that is first seen when powering up the unit, or after any period of inactivity the TReX will automatically revert to this screen. Setting to DEFAULT will unset the last custom set screen and will return to the factory default main screen. Setting to SET will set the screen to be the screen that was last used before entering the menu. MENU PIN When the MENU PIN is set to a non-zero value, the MENU will be prevented from opening until the PIN is entered. Prevents accidental or unauthorised misconfiguration. If the PIN is ever forgotten, the PIN is visible using the command *CONFIG or viewing the WTE_CONF.INI file through a USB connection. Once the MENU is unlocked, it will remain unlocked until the unit is restarted. FACTORY Sub menu responsible for calibration screens and setting of feature unlock keys. TEST Test sub menu for generation of test messages and testing of outputs. WTE Limited, 2018 Christchurch New Zealand Page 34 of 158 TReX User Manual v2.14 Firmware REGULATORY Regulatory items such as FCC-ID*.
*Note: Publication number 784748-D01, FCC-Part 90 allows for devices with integrated display to not require a printed label on the device holding this information. WTE Limited, 2018 Christchurch New Zealand Page 35 of 158 TEST Sub Menu TReX User Manual v2.14 Firmware 1-8 Digital output to test. Pressing up pulls the output to ground for 60 seconds. Pressing down releases the output. WTE Limited, 2018 Christchurch New Zealand Page 36 of 158 TReX User Manual v2.14 Firmware FACTORY Sub Menu This menu is typically for factory use only or to return the unit to a factory new state. DIAGNOSTICS Debug for factory use only. SERIAL NUM Read only unit serial number. KEY The key used to unlock unit features. If features are purchased after sale, a new key may be required to be entered here. They key is unique to the unit serial number. SET DEFAULTS Used to set the TReX back to factory defaults. Calibration data is not cleared. This may be used at any time to restore the unit to a known starting point. WTE Limited, 2018 Christchurch New Zealand Page 37 of 158 TIME Sub Menu TReX User Manual v2.14 Firmware HOUR, MIN, DAY, MONTH and YEAR Configuration of the real time clock. SOURCE Determines how time is maintained in the TReX. RTC uses the internal real time clock to keep time. NONE only uses the internal processor clock. This will only be the time since last FLEX takes the time from the FLEX transmission time details (if present). SEQ TEST takes the time from national paging network (used in N.Z. only). reset. WTE Limited, 2018 Christchurch New Zealand Page 38 of 158 SPECTRUM Menu TReX User Manual v2.14 Firmware SPECTRUM Displays the radio spectrum using the settings in this menu. Signals between -128dBm and 0dBm can be displayed. Power levels above 17dBm (50mW) will destroy the receiver input. CENTRE Displays the centre frequency to be displayed on the screen. HZ/DIV Either 250kHz, 10kHz or 2kHz. The screen is 6 divisions wide in 120 steps. The RBW (receiver bandwidth) and frequency span is automatically set when the Hz/Div changes. HZ/DIV 250kHz 10kHz 2kHz RBW 25kHz 1kHz 500Hz Frequency Span 3MHz 120kHz 24kHz SAMPLE When set to CONT the spectrum analyser screen will be updated with new values approximately twice a second. When set to PEAK only higher values will be written to the screen. At any time, the ENTER button can be pressed on the SCREEN to clear the screen and load new PEAK values. BASE Defines the base signal level on the screen. When set to -100, only signals with a strength greater than -100 dBm will be displayed. Range is -130 dBm to -60 dBm. dB/DIV WTE Limited, 2018 Christchurch New Zealand Page 39 of 158 Scales the signal level displayed. Either 10 dB/DIV or 20 dB/DIV can be set. When 20 is set a dynamic range of 120 dB is possible. TReX User Manual v2.14 Firmware WTE Limited, 2018 Christchurch New Zealand Page 40 of 158 RX Menu TReX User Manual v2.14 Firmware RX When ENABLED the TReX receiver is enabled. When DISABLED an operating current reduction of 50mA is typical. FREQUENCY Specifies the receive frequency in Hz (range limited to the variant of product). MODULATION Specifies modulation parameters. This includes whether the modulation is 2 or 4 levels GFSK plus the channel width. 512_25 indicates 512 baud with 25kHz channel spacing (2 level GFSK). 9600-4L_6 indicates 9600 baud with a 6.25kHz channel spacing (4 level GFSK). Modulation rates from 512 baud to 48K baud can be set. PROTOCOL Specifies the protocol to apply for serial output, accepts WTE, CUSTOM, RAW and AUX. Other protocols may be added and supported upon request. MODE WTE Limited, 2018 Christchurch New Zealand Page 41 of 158 TReX User Manual v2.14 Firmware Specifies the transport mode of the receiver (how the information is received over the air). POCSAG_A must be used in order to receive alphanumeric messages. POCSAG_N must be used in order to receive numeric messages. WTE_EN must be used in order to receive 8 bit characters (POCSAG_A transmits 7 bit characters only). FLEX must be used in order to receive and decode 2 level 1600 baud FLEX messages. MSG LOG When ENABLED all received messages are written to RX-LOG.TXT on the SD card. Should be set to DISABLED in critical applications when the SD card cannot be allowed to completely filled (such as when unsupervised). DISABLED:
Messages are not logged. ENABLED:
All messages displayed are written to internal SD card and can be viewed on the message history screen. CLEAR:
Setting to CLEAR will result in RX-LOG.TXT being deleted when exiting the menu. RIC RANGES Specifies up to 8 RIC RX ranges for decoding. Messages received with RIC codes not allowed with the RX_RANGE will be discarded by the receiver. Note: When configuring the RIC RANGE, the LOW RIC must not be higher than the HIGH RIC and the HIGH RIC must not be lower than the LOW. Any attempt to configure illegally will reset the RIC RANGE to ensure these rules are not broken. Any RIC RANGE with a LOW RIC set to 0000000 will NOT be used. BUSY LEVEL Specifies the busy level for the configured channel. The configured value is the signal level from 0 to -130 (in dBm). If the signal strength on the receiving channel is above this configured value, the channel will be considered to be busy. Transmissions will not be possible if the channel is considered to be busy. After a period of 5 seconds of the channel being busy, the transmitter will transmit anyway. Note: If the TReX continually reports BUSY, issue the command *RSSI<CR> (or view the RSSI screen) to inspect the noise floor and adjust the busy level appropriately. WTE Limited, 2018 Christchurch New Zealand Page 42 of 158 LINK FAIL TIME This is the number of seconds (up to 240) that is allowed to pass in-between received messages without setting the LINK FAIL output (if LINK FAIL output is configured). TReX User Manual v2.14 Firmware ALERT Visual notification and repeating beep (at a configurable interval) when a message is received that meets the conditions for raising an alert. See ALERT FILTER. If the ALERT output is enabled the configured output will also operate. Can be configured from 0-250 seconds. When set to 0 the alert is disabled. DEMOD Access to the raw signal demodulation screen allowing raw data and recovered clock signals to be viewed in real time. FILTERS The TReX supports the use of message filters. These filters inspect the content of incoming messages and then make decisions on whether to ignore or pay attention to these messages based on filter setting. There are 3 types of supported filters:
Include filters (messages must include one or more of the matching entries). Exclude filters (messages must NOT include any of the matching entries). Alerts filters (Alerts are raised for message with any of the matching entries). Alert filters take priority over Exclude filters. This means that if PUKEKO has been specified in ALERT.TXT and FIRE is specified in EXCL.TXT then a message with FIRE AT PUKEKO PLACE, although it would normally be excluded, would still raise an alert and display the message. Each of the filter matching entries are NOT case sensitive and can be part of a longer word or phrase. Entries are allowed to be more than one word e.g. THIS IS A TEST This will match on ThiS is a TEST but not the single words in the entry, unless they have been added as separate match entries. Up to 15 key words can be stored, each up to 20 characters in length. There must be no ASCII WTE Limited, 2018 Christchurch New Zealand Page 43 of 158 TReX User Manual v2.14 Firmware control characters within the key words used and each matching phrase must be on a new line. ALERT FILTER This filter option allows the use of a text file called ALERT.TXT to be stored and modified on the SD card (accessible via the USB port). If the feature is enabled (ALERT set to value), this file (if present) will be searched for key words. If any of these key words are found then an alert is raised based on the alert configuration (beep plus operation of a configured output). Example:
A text file named ALERT.TXT is added to the SD card root directory that has the following contents:
TSUNAMI MAJOR EMERGENCY All messages WITH these key words will result in an alert being raised. These messages will be displayed and logged normally as per the system configuration. All other messages will still be decoded and displayed based on RIC range settings. ALERT set to DISABLED:
Messages are not filtered to raise an alert. When DISABLED messages can still raise alerts based on the alert settings within the menu. ALERT set to a value:
Messages are filtered to raise an alert. When set to a value only the messages found in the ALERT.TXT file will raise an alert. No other messages, even if displayed will raise an alert. NOTE: Filtered messages must still fall within configured RIC ranges in order to be displayed. NOTE: When the ALERT.TXT filter option has been set a value (enabled), alerts are raised by matching key words in arriving messages that are within the specified RIC range. When this option is ENABLED, only the messages matching these key words will raise an alert (beep and or output changing state). All other incoming messages within the RIC range configured will no longer raise any alert (as is the case when ALERT.TXT is absent). NOTE: Restarting is required in order to load the ALERT.TXT settings. This applies both when enabled via the serial port or from the menu. INCL FILTER This filter option allows the use of a text file called INCL.TXT to be stored and modified on the SD card (accessible via the USB port). If the feature is ENABLED, this file (if present) will be searched for key words. Any of these key words MUST be present in order for the message to be processed. NOTE: messages received for filtering must still fall within configured RIC ranges. Example:
A text file named INCL.TXT is added to the SD card root directory that has the following WTE Limited, 2018 Christchurch New Zealand Page 44 of 158 TReX User Manual v2.14 Firmware contents:
FIRE EMERGENCY All messages WITHOUT these key words WILL BE DISCARDED. Even though non matching messages are discarded, the receiver OK indicators and timers will continue to operate normally. INCL FILT set to DISABLED:
Messages are not filtered INCL FILT set to ENABLED:
Messages are filtered EXCL FILTER This filter option allows the use of a text file called EXCL.TXT to be stored and modified on the SD card (accessible via the USB port). If the feature is ENABLED, this file (if present) will be searched for key words. Any of these key words MUST NOT be present in order for the message to be processed. Example:
A text file named EXCL.TXT is added to the SD card root directory that has the following contents:
THIS IS A TEST DISCARD All messages WITH these key words WILL BE DISCARDED. Even though non matching messages are discarded, the receiver OK indicators and timers will continue to operate normally. EXCL FILT set to DISABLED:
Messages are not filtered EXCL FILT set to ENABLED:
Messages are filtered WTE Limited, 2018 Christchurch New Zealand Page 45 of 158 Protocol Menu TReX User Manual v2.14 Firmware TX Specifies the protocol to apply for serial input. Accepts WTE, CUSTOM, RAW, AUX and in some cases others as required or specified. RX Specifies the protocol to apply for serial output. Accepts WTE, CUSTOM, RAW, AUX and in some cases others as required or specified. SENT RESP This the response out the serial port at the completion of each transmitted message. By default this is Page Sent. Note: The default overriding response for WT protocol is WT[xxx]. To change the sent response to Page Sent a leading * character must be used. e.g. *Page Sent. MODBUS Specifies parameters used for the MODBUS protocol. RAW Specifies parameters used for the RAW protocol. CUSTOM Specifies parameters used for the CUSTOM protocol. WTE Limited, 2018 Christchurch New Zealand Page 46 of 158 TCP-IP Menu TReX User Manual v2.14 Firmware TCP-IP The TCP-IP configuration lets you choose the TCP protocol for use on the TReX. WEB:
This setting allows the TReX to be monitored and configured from a Chrome web browser either on a PC or mobile device. SERVER:
This setting allows the TReX to be operated as a TCP server on the specified TCP port. SERVER would typically be used if a short term connection was required, such as to change a configuration item or send a message for transmitting. Only a single connection is allowed, however multiple users can conceivably connect in this mode for short durations in order to offload content to be transmitted. A long term or held connection will allow decoded messages to be viewed in real-time (preventing further connections). CLIENT:
This setting allows the TReX to be operated as a TCP client on the specified TCP port and REMOTE IP. SERVER would typically be used if a remote device required a long duration or permanent connection. This would be desirable if monitoring decoded messages. WEB+SERVER:
Concurrent WEB and SERVER functionality. WEB+CLIENT:
WTE Limited, 2018 Christchurch New Zealand Page 47 of 158 TReX User Manual v2.14 Firmware Concurrent WEB and CLIENT functionality. DISABLED:
Setting to DISABLED ensures the maximum possible power savings even when an Ethernet cable has been connected. When IP is DISABLED, current consumption will reduce by approximately 150mA and disable the TCP stack. HOST This is the name that can be associated to the TReX. This name can be used directly instead of the IP address to address the TReX. By default is WTE-TReX ADDR IP Address for access to the TReX. MASK IP Mask GATE IP Gateway DNS1 Primary Domain Name Server DNS2 Secondary Domain Name Server. PORT The port to use for TCP client TCP server connections. Default is 5080. MAC Non-editable MAC address. WTE Limited, 2018 Christchurch New Zealand Page 48 of 158 Telemetry Menu TReX User Manual v2.14 Firmware MODE DISABLED:
there are no autonomous transmissions. SERIAL LINK:
Serial arriving on an enabled serial port is sent to a remote TReX unit. IO MIRROR:
All local unit enabled inputs are mirrored to outputs of a remote device based on the IO MIRROR configuration. IO_MIRROR can only support 2 TReX units. SCADA monitoring and controlling is not possible in this MODE. SCADA_MASTER (Optional feature only):
The TReX unit can be connected via Mobus (TCP or RTU serial). This unit can then optionally report the status (and control) SCADA_SLAVE TReX units. SCADA_SLAVE (Optional feature only):
The TReX can be installed in a remote location and wirelessly controlled by a SCADA_MASTER. See SCADA Configuration. LOCAL ID It is possible to have many TReX units operating on the same frequency. This is the ID that the REMOTE TReX needs to use in its REMOTE ID field in order to communicate. REMOTE ID WTE Limited, 2018 Christchurch New Zealand Page 49 of 158 TReX User Manual v2.14 Firmware This is the ID of the remote device that all inputs will be sent to. When the MODE is configured to be SCADA_MASTER this is the ID of the first SCADA_SLAVE TReX. All SCADA_SLAVES must be consecutively numbered following this ID. When the MODE SCADA_SLAVE is used, the REMOTE_ID is configured to be the same as the LOCAL_ID (this is required by the SCADA_MASTER to identify the source of the transmission). REMOTES This parameter is only used when the MODE is SCADA_MASTER. This is the number of wireless SCADA_SLAVE units that the SCADA_MASTER will communicate with. INPUTS This is a shortcut to the INPUT configuration menu. OUTPUTS This is a shortcut to the OUTPUT configuration menu. If the OUTPUT is DISABLED, then messages from a remote unit can NOT change the units outputs. This may be desired if the OUTPUT is already configured for another purpose such as LINK FAIL OUTPUT. Outputs to be used should be set to LATCHED. REFRESH TIME How long in seconds before sending all input information again. If any INPUT changes then there is an immediate transmission. The REFRESH TIME ensures that if a message is lost, the remote device will eventually resynchronise its OUTPUTS with the local device INPUTS. DELTA ADC TX Analog data is transmitted after each REFRESH TIME count elapses. This field allows an immediate transmission if it has changed by a certain amount since its last transmission. This is the raw ADC count that is a value up to 1023. Min value is 10 to ensure that very small changes do not result in continuous transmissions in an electrically noisy environment. SERIAL LINK Configuration of all SERIAL LINK Settings MODBUS Configuration of all MODBUS Settings WTE Limited, 2018 Christchurch New Zealand Page 50 of 158 SERIAL LINK Menu TReX User Manual v2.14 Firmware This a duplication to settings used by the RAW protocol. These settings allow the transmission to be optimised. TX TIMEOUT This is the period of serial port inactivity in 10mS steps that the TReX will wait before transmitting. In this case, placing a small delay between characters will result in poor transmission efficiency. TX LEN This configures how many characters must be buffered before transmission. If the TX TIMEOUT has been configured, then the TX TIMEOUT will take priority. TX CHAR This configures a special character that can be used to mark the end of a serial message. This could be configured to be a carriage return for example (value to use is 13 for a carriage return). When any carriage return character is seen, then an immediate transmission would be forced. The TX LEN and TX TIMEOUT items take priority. The value of this configuration item is the decimal value of the ASCII character. Please refer to a standard ASCII chart for decimal values for ASCII characters (1-127). WTE Limited, 2018 Christchurch New Zealand Page 51 of 158 STORE FWD Menu TReX User Manual v2.14 Firmware OPERATION When store forward operation ENABLED the unit is used to listen to transmissions in the area, decode the messages and retransmit again to provide greater coverage than would normally be possible. When DISABLED there is no store and forward function. The non zero value set is the delay in 100ms steps after each transmission. This delay allows time for any downstream forwarding equipment to clear the message. All messages received are immediately queued for transmission, and up to 5 messages may be retransmitted after the store forward delay. DUPL REJECT Setting to 0 disables the feature, otherwise this is the number of seconds to reject identical messages for up to 60 seconds. Duplicate rejection operates only on messages decoded for forwarding. This means that receiving of duplicate messages is not prevented (nor the transmission of same messages resulting from a protocol command), but when used as part of a simple store forward system re-queueing of messages can be controlled. Duplicate reject only tests the previous 10 messages in the historic transmit queue. WTE Limited, 2018 Christchurch New Zealand Page 52 of 158 Inputs Menu TReX User Manual v2.14 Firmware 1-8 Configuration of messages that are transmitted when an input changes. Receiver only TReX units instead of transmitting can directly send WT protocol messages via serial ports or a TCP connection. BATT Treated as the 9th input. Messages transmitted when system voltage is high or low (high and low levels configurable). ADC 1-2 Treated as Inputs 10 and 11. Messages transmitted when ADC levels are above or below set thresholds. ADC CAL This manages calibration of analog inputs. WTE Limited, 2018 Christchurch New Zealand Page 53 of 158 ADC CAL Sub-Menu TReX User Manual v2.14 Firmware When the analog inputs are being read, scaling can be applied that allows the user to specify an INPUT from 0-1023 over a useful range from MIN to MAX. For example, if MIN is 200 and MAX is 400, then any analog INPUT below 200 will be SCALED to 0. Any INPUT above 400 will be SCALED to 1023. An INPUT of 300 will return a SCALED value of 512. This is useful if a small voltage range is of interest, such as 1-5V instead of 0-10V. See following calibration procedure for full example. 1-2 Access to calibration items for ADC 1 and ADC 2. MIN This is the minimum used INPUT ADC value. If no scaling is to be applied set to 0. MAX This is the maximum used INPUT ADC value. If no scaling is to be applied set to 1023. SCALED This is a read only field that displays a value from 0-1023. INPUT This is a read only field that displays the raw analog input value from 0-1023. The INPUT is not scaled. WTE Limited, 2018 Christchurch New Zealand Page 54 of 158 TReX User Manual v2.14 Firmware Calibration Procedure for Voltage Inputs:
1. Connect a voltage source (with an input resistance not more than 2 k ohm). 2. Set the voltage source to the minimum voltage that will be used. 3. Set ADC CAL->MIN to the value shown in the INPUT field. 4. Set the voltage source to the maximum voltage that will be used (up to 16V). 5. Set ADC CAL->MAX to the value shown in the INPUT field. 6. Check that when the minimum voltage is connected, the SCALED field displays close to 0. 7. Check that when the maximum voltage is connected, the SCALED field displays close to 1023. 8. Check that when a mid voltage between the maximum and minimum is connected, the SCALED field displays a mid value between 0 and 1023. 9. Exit MENU and settings will be saved. WTE Limited, 2018 Christchurch New Zealand Page 55 of 158 Input Config Sub-Menu TReX User Manual v2.14 Firmware These input configuration screens repeat for each of the 8 inputs plus the BATT and ADC inputs. INIT STATE Input messages are transmitted when the input changes from one state to another. On start-up the first transmitted message depends on this configuration. UNSET will ensure that there is never a transmission on start, whereas the HIGH or LOW states assume a certain start condition, so that an immediate transmission on start is possible. UNSET The input state is read on start-up. There will not be a transmission until the input changes (if configured to transmit on that HIGH or LOW level). HIGH The input is considered to be HIGH on start. If on start the input is read and found to be LOW, then there will be an immediate transmission (if configured to transmit). LOW The input is considered to be LOW on start. If on start the input is read and found to be HIGH, then there will be an immediate transmission (if configured to transmit). WTE Limited, 2018 Christchurch New Zealand Page 56 of 158 TReX User Manual v2.14 Firmware TX COUNT LOW If set to 0, then there will there will be NO transmissions when moving to the LOW state. If non-zero then this is the number of times the LOW message will be transmitted. If there is a change of state again, then any remaining transmissions are cancelled. When set to a non-zero TX COUNT, the input level is considered to be ENABLED, and displayed as ENABLED on the upper menu level. RETX DELAY LOW How long in seconds before sending the next message if set to more than 1. DEBOUNCE LOW How long in seconds that the input must be settled at a LOW level before transmitting THRESH LOW When configuring inputs 1-8, this field has no function. On the BATT input this is the voltage that the TReX BATT input is considered to be low. A voltage below this may result in a BATT transmission if configured. On the ADC 1 and ADC 2 inputs this is the ADC count that the TReX ADC input is considered to be low. An ADC count below this may result in an ADC input transmission if configured. MSG LOW The message that is transmitted (formatted for the selected protocol) when the input moves to the LOW level. Input messages must always use WT Protocol. TX COUNT HI If set to 0, then there will there will be NO transmissions when moving to the HIGH state. If non-zero then this is the number of times the HIGH message will be transmitted. If there is a change of state again, then any remaining transmissions are cancelled. When set to a non-zero TX COUNT, the input level is considered to be ENABLED, and displayed as ENABLED on the upper menu level. RETX DELAY HI How long in seconds before sending the next message if set to more than 1. DEBOUNCE HI How long in seconds that the input must be settled at a HIGH level before transmitting THRESH HI When configuring inputs 1-8, this field has no function. On the BATT input this is the voltage that the TReX BATT input is considered to be high. A voltage above this may result in a BATT transmission if configured. On the ADC 1 and ADC 2 inputs this is the ADC count that the TReX ADC input is considered to be HIGH. An ADC count above this may result in an ADC input transmission if configured. WTE Limited, 2018 Christchurch New Zealand Page 57 of 158 TReX User Manual v2.14 Firmware Note: The BATT input threshold settings are also used to set the battery icon on the main screens. MSG HI The message that is transmitted (formatted for the selected protocol) when the input moves to the HIGH level. Input messages must always use WT Protocol. WTE Limited, 2018 Christchurch New Zealand Page 58 of 158 Outputs Menu TReX User Manual v2.14 Firmware 1-8 The output to configure. If the output has been configured for general output control through telemetry or messaging the output must be configured to LATCHED or MSHOT. In order to set to LATCHED or MSHOT the output mode must be set to TELEMETRY in the Output Config Sub-Menu. If the output has already been assigned for a special output function, the function will be displayed against the output e.g. RF ERROR. If the output has been configured to more than one function, the output setting will display MULTI. The output can be configured to operate on many actions at once. Note: Care must be taken when assigning an output to more than one function as the behaviour of the output can be difficult to predict or determine the trigger for the output change. In general, assignment of an output to more than one function is not recommended. WTE Limited, 2018 Christchurch New Zealand Page 59 of 158 TReX User Manual v2.14 Firmware DAC CAL Configures calibration of analog output 1 and 2. See DAC CAL Sub-Menu. ALERT When DISABLED there is no output change when an ALERT condition is met. When set to 1-
8 this is the output that will operate when an ALERT is signalled. BUSY When DISABLED there is no output change when receive channel is BUSY. When set to 1-8 this is the output that will be high when the signal strength on the channel exceeds the RX BUSY LEVEL. LINK FAIL When DISABLED there is no output change when the RX LINK FAIL time is exceeded between received messages. When set to 1-8 this is the output that will be high indicating no activity on the channel. Typically the LINK FAIL output would be used in conjunction with a known periodic message from another transmitter. TEMP This is the over temperature output. When DISABLED there is no output change when the TReX has reached the max temperature. The max temperature is set in MENU->SYSTEM-
>OVERTEMP. This is the TReX board operating temperature and NOT the ambient temperature. When set to 1-8 this is the output that will be high when the board temperature exceeds the OVERTEMP setting. RF ERROR When DISABLED there is no output change when an RF ERROR has been detected. When set to 1-8 this is the output that will be high when there an antenna mismatch or low power condition at the beginning of a transmission. The output will be set high for 3 seconds by default. This output is linked to MENU->TX->MIN PWR, MAX PWR and MAX I. WTE Limited, 2018 Christchurch New Zealand Page 60 of 158 Output Config Sub-Menu TReX User Manual v2.14 Firmware MODE When set to TELEMETRY the output can be controlled through TELEMETRY settings or through output control messages that may be received. Setting to TELEMETRY will show the output to be configured to either LATCHED or MSHOT depending on the MSHOT setting. On start outputs are ALWAYS LOW. After the expiration of any MONOSHOT period for an output, the OUTPUT will return to the LOW state. When RIC RANGE X, then the output is configured to close, either LATCHED or MSHOT when a message is received with a RIC within that RANGE. RIC RANGE N controls OUTPUT N. MONOSHOT If LATCHED or RIC RANGE the output will remain in the set state until another message is received to change the state. If set to a time, then after receiving a message to operate HIGH the output will return to a LOW state after this period of time has passed. WTE Limited, 2018 Christchurch New Zealand Page 61 of 158 DAC CAL Sub-Menu TReX User Manual v2.14 Firmware Analog outputs can be configured to operate as constant voltage or constant current. This makes the outputs suitable for outputs such as 0-10V or 4-20mA. The analog output is current limited internally at approx 35mA. DAC Output impedance is 5 ohms. In VOLTAGE mode:
Ensure that the wiring SERIES impedance is as low as possible. There will be a voltage drop across any series resistance that will affect the output voltage. How much the output will vary will depend on the load of the connected equipment. This load resistance preferably should not be less than 2k ohms. In CURRENT mode:
Ensure that the full loop impedance is less than 500 ohms and at least 100 ohms. Add a small series resistor if required since the internal series resistance is only 5 ohms. When the analog outputs are being controlled, scaling can be applied that allows the user to specify an OUTPUT from 0-1023 over a useful range from MIN to MAX. For example, if MIN is 200 and MAX is 400, then setting the analog output to a SET value of 1023 will in fact set the OUTPUT to the MAX value of 400. SET configured to 0 will set the OUTPUT to the MIN value of 200. A SET value of 512 will set the OUTPUT to a value of 300. See following calibration procedure for full example. MIN This is the minimum used unscaled DAC count of interest. If no scaling is to be applied set to 0. MAX This is the maximum used unscaled DAC count of interest. If no scaling is to be applied set to 1023. SET This sets the output as a value between 0-1023 that is scaled and applied between the MIN and WTE Limited, 2018 Christchurch New Zealand Page 62 of 158 TReX User Manual v2.14 Firmware MAX OUTPUT values. Regardless of the MIN and MAX settings, the full control range of 0-
1023 can be used. This is a test parameter only, useful for calibration. This is the value that the user would send to the TReX in order to control the outputs. OUTPUT This is a read only field showing the current flowing and unscaled raw output. This value will sit between MIN and MAX. MODE Sets either constant VOLTAGE or CURRENT mode. When in VOLTAGE mode the output is fixed depending on the output set value. This mode is used for outputs such as 1-10V, 1-5V or any other voltage as configured. When in CURRENT mode the set value is the desired current that is to be maintained. This is used for outputs such as 4-20mA, 0-20mA or any other current up to 30mA as configured. CAL mA This how much to adjust the output current sense to read correctly. This field has no function when the MODE is set to VOLTAGE. This must be set by connecting an ammeter through a small series resistor such as 100 ohms. This setting would then be adjusted until the reading is the same as the reading from the ammeter. Calibration Procedure for Voltage Output 1. Connect load (a resistance not less than 2 k ohm). 2. Set DAC output to 0 using the DAC->OUT parameter. 3. Alter DAC->MIN until the low limit output can be obtained. 4. Set DAC output to 1023 (maximum) using DAC->OUT 5. Alter DAC->MAX until the high limit output has been set. The output voltage does not vary with power supply, but the maximum output IS based on the TReX input supply voltage. Typically with a supply voltage of 12V the DAC max output is 10.0V. 6. Exit MENU and settings will be saved. Calibration Procedure for 4-20mA Current Output 1. Connect load with ammeter in series through a 100R resistor. 2. Set DAC->MIN to 117 and DAC->MAX to 583 3. Set DAC output to 0 4. Adjust DAC->MIN until output current is approximately 4mA. 5. Set DAC output to 1023 6. Adjust DAC->MAX until output current is approximately 20mA. 7. Exit MENU and settings will be saved. WTE Limited, 2018 Christchurch New Zealand Page 63 of 158 TReX User Manual v2.14 Firmware Serial Command Configuration Most items that can be changed via the MENU can also be changed through serial commands. There are some additional commands that make the TReX more usable when being managed via a serial connection. These are listed immediately below. These commands must begin with the character * and are processed with a carriage return character. Any characters before the * may result in the command not being processed. Main Commands
*REBOOT Forces the unit to immediately restart. Usage:
*REBOOT<CR>
*CONFIG Displays current configuration. Usage:
*CONFIG<CR>
*SAVE Saves all configuration settings (all configuration changes are restored on start-up). Usage:
*SAVE <CR>
*LIST Displays all available commands. This command also lists many specific field names that need to be used with listed commands. Usage:
*LIST<CR>
*DEFAULTS Forces to reset temporary to factory default settings. The user must issue the *SAVE<CR>
command in order to write these default settings to internal memory. Usage:
*DEFAULTS<CR>
WTE Limited, 2018 Christchurch New Zealand Page 64 of 158 TReX User Manual v2.14 Firmware
*RSSI Returns the receiver signal strength in -dBm. (returns between 0 and -130). Usage:
*RSSI<CR>
*USERPASS Sets the web and TCP user and password. User must be at least 3 letters and password must be at least 4 letters. These credentials are requested for each new web and TCP connection. Typical usage:
*USERPASS=admin:TReX<CR>
When prompted for a login when using a TCP connection (not through web browser), login with the full user and password together. e.g. in response to login:
enter admin:TReX The TReX will immediately report if successfully logged in. To completely disable all web and TCP connection user and passwords, enter
*USERPASS=none:none<CR>
*SAVE<CR>
By default the user and password is set to none:none
*IO Returns all input and output states. Typical usage:
*IO<CR>
Typical output:
IO=I:01000000--- O:00000000 ADC:257,252 DAC:0,0 In this typical output, there are 11 inputs shown. First 8 are the digital inputs. The 9th input is 1 or 0 based on battery high/low thresholds set. Inputs 10 and 11 are ADCs, again displayed as 1 or 0 based on set thresholds. The - is shown when the input level is unknown, such as when an input is between the high and low configured thresholds. Output states for all 8 outputs follow, then ADC inputs 1 and 2 and finally the current DAC settings. WTE Limited, 2018 Christchurch New Zealand Page 65 of 158 TReX User Manual v2.14 Firmware
*TEMP Returns temperature of first the digital board, then the RF temperature sensor. This is NOT the ambient temperature. Temperatures in excess of 100 degrees C are completely normal under typical transmitting operation. Usage:
*TEMP<CR>
Typical output:
TEMP=DIG:55.0C RF:60.1C
*PWR Returns current forward power ADC count and system current both at the time of reading and recorded during the last transmission. Usage:
*PWR<CR>
Typical output:
PWR=0,34,0.28,1.23 The first parameter is the forward power ADC count at the time of reading. The second value is the forward power recorded during the last message transmission. Parameter 3 is the system current. Parameter 4 is the system current recorded during the last message transmission.
*VER Sends the TReX sign on message back to the user. This is useful to determine the model and serial number of the unit. Usage:
*VER<CR>
*BYPASS This a command that is useful for test and special serial control cases. This command specifies a RIC code and beep level that allows processing as if arriving from the receiver. In order for the message (in the case below Test Message) to arrive as a message, a RIC range must be configured in the TReX to suit.
*BYPASS=[NNNNNNN:L]MMMMMMMM<CR>
where:
[ is the character [
WTE Limited, 2018 Christchurch New Zealand Page 66 of 158 TReX User Manual v2.14 Firmware NNNNNNN are 7 digits specifying the RIC code to be used for the message
: is the character :
L is beep level for the message to be processed from 0-3.
] is the character ]
MMMMMM is the payload of the message to be processed. Typical Usage 1:
*BYPASS=[1234567:1]Test Message<CR>
Test Message will be added to the RX message screens, logged etc, as if received across the air. Typical Usage 2:
*BYPASS=[1234567:1][[01]12345-8]<CR>
[[01]12345-8] will be added to the RX message screens, logged etc., as if received across the air. In this case, the message will also be processed as a WTE Output Protocol message and immediately operate the TReX outputs.
*LAB Set the unit in transmit mode, it can be configured to transmit carrier only or modulated. This feature together with the *RSSI command are useful when antenna alignment is necessary.
*LAB syntax:
*LAB=x,y<CR>
Where:
x is used to enable (1) or disable (0) the carrier; Setting to 2 enables random modulation for the configured transmit modulation. y is the time in seconds which the TReX will be transmitting for. Typical usage:
*LAB=1,10<CR>
Note: *LAB=1<CR> can be used, as it will enable carrier for 60 seconds WTE Limited, 2018 Christchurch New Zealand Page 67 of 158 TReX User Manual v2.14 Firmware Transmit Commands
*TX_FREQ Specifies the transmit frequency in Hz e.g.
*TX_FREQ=160000000<CR>
*TX_PROTO Specifies the protocol to apply for serial input. Accepts WTE, CUSTOM, RAW and AUX. Typical usage:
*TX_PROTO=WTE<CR>
Note: See protocol section for more details on protocols and configuration.
*TX_BAUD Specifies the baud rate of the transmitter when using a protocol that does not permit a baud rate to be specified. Accepts: 512_25, 512_12, 512_6, 1200_25, 1200_12, 1200_6, 1600_25, 2400_25, 2400_12, 2400_6, 3200-4L_25, 4800_25, 4800_12, 4800-4L_6, 9600_25, 9600_12, 9600-4L_25, 9600-
4L_12, 16K-4L_25, 16K-4L_12, 32K-4L_25 Typical usage:
*TX_BAUD=512_25<CR>
*TX_MODE Specifies the transport method of the transmitter (how the information is transmitted over the air). WTE_EN must be used in order to transmit 8 bit characters (POCSAG_A transmits 7 POCSAG_A must be used in order to transmit alphanumeric messages. POCSAG_N must be used in order to transmit numeric messages. bit characters only). Accepts POCSAG_A, POCSAG_N and WTE_EN. Typical usage:
*TX_MODE=POCSAG_A<CR>
WTE Limited, 2018 Christchurch New Zealand Page 68 of 158 TReX User Manual v2.14 Firmware
*TX_LEVEL Specifies the default level of messages transmitted. This is sometimes referred to as Beep Level. This is a value 0-9, however, when POCSAG is the transport method, only 0-3 will be used. Typical usage:
*TX_LEVEL=3<CR>
*TX_CAP Specifies the default code used to identify transmissions (same as the RIC code). The TX_CAP code would only be used by protocols that do not require the CAP code to be specified. TX_CAP syntax:
*TX_CAP=X:nnnnnnn<CR>
Where:
X, is the input range index from 1 to 9 nnnnnnn, This code can be any number between 8 and 2000000. Typical usage:
*TX_CAP=1:1324560<CR>
*TX_PERIODIC Allows a periodic message to be transmitted. This could be used as a heartbeat to confirm that the system is continuing to operate as expected. WT protocol must be used for the periodic message.
*TX_PERIODIC=TT,MMMM<CR>
where:
TT is the time in seconds between transmissions (0-255. 0 disables the feature). MMMM is the periodic message to transmit (up to 50 characters). Typical usage:
*TX_PERIODIC=10,WT1234560A10 Test_Message<CR>
*TX_PREAMBLE Sets the preamble length in multiples of 32 bits. Short preambles allows the messages to be transmitted quickly. Long preambles are typically used in conjunction with a matching receiver to save battery WTE Limited, 2018 Christchurch New Zealand Page 69 of 158 TReX User Manual v2.14 Firmware power when the receivers is in deep sleep mode. The POCSAG standard uses a setting of 18 (576 bits configured in steps of 32). This very long preamble means that paging receivers need only to wake briefly once per second (at 512 baud) in order to check for an incoming message. If the receiver is always powered and receiving, then much shorter preambles can be used, and in some cases halve the channel activity. When the TReX is used as transmitter and receiver at both ends of the link, a setting of 2 (64 bits) will work equally well. Typical usage:
*TX_PREAMBLE=18<CR>
*TX_LEAD Sets the transmit lead-in and lead-out time in multiples of 10ms. Some receivers require time to settle when a transmitter is keyed up. The command allows the lead-in and lead-out times to be set.
*TX_LEAD=II,OO<CR>
where:
II is the lead-in time. This is the duration after the carrier is applied BEFORE data is transmitted. Default is 0, max is 50 (500ms). OO is the lead-out time. This is the duration AFTER data is transmitted that the carrier is applied before keying down the transmitter. Default is 0, max is 50 (500ms). Typical usage:
*TX_LEAD=5,5<CR>
WTE Limited, 2018 Christchurch New Zealand Page 70 of 158 TReX User Manual v2.14 Firmware Receive Commands
*RX_ENABLE Allows the receiver to be disabled to save power if required. Typical usage:
*RX_ENABLE=1<CR>
*RX_FREQ Specifies the receive frequency in Hz (range limited to the variant of product). Typical usage:
*RX_FREQ=160000000<CR>
*RX_BAUD Specifies the baud rate of the receiver. Accepts: 512_25, 512_12, 512_6, 1200_25, 1200_12, 1200_6, 1600_25, 2400_25, 2400_12, 2400_6, 3200-4L_25, 4800_25, 4800_12, 4800-4L_6, 9600_25, 9600_12, 9600-4L_25, 9600-
4L_12, 16K-4L_25, 16K-4L_12, 32K-4L_25 Typical usage:
*RX_BAUD=512_25<CR>
*RX_PROTO Specifies the protocol to apply for serial output, accepts WTE, CUSTOM, RAW and AUX. See protocol section for more detail on protocols and configuration. Typical usage:
*RX_PROTO=WTE<CR>
*RX_MODE Specifies the transport method of the receiver (how the information is received over the air). POCSAG_A must be used in order to receive alphanumeric messages. POCSAG_N must be used in order to receive numeric messages. WTE_EN must be used in order to receive 8 bit characters (POCSAG_A transmits 7 bit characters only). Accepts POCSAG_A, POCSAG_N, WTE_EN and FLEX. Typical usage:
WTE Limited, 2018 Christchurch New Zealand Page 71 of 158
*RX_MODE=POCSAG_A<CR>
TReX User Manual v2.14 Firmware
*RX_RANGE Specifies up to 8 CAP RX ranges for decoding. Messages received with CAP codes not within the RX_RANGE will be discarded by the receiver. CAP codes should not fall within multiple ranges. If an output has been configured to operate on a range match, a second output configured for another range with the same CAP code will not operate.
*RX_RANGE=N:LLLLLLL,HHHHHHH (where N is the range between 1 and 8, LLLLLLL is the lowest cap code to match, HHHHHHH is the highest). Typical usage:
*RX_RANGE=1:8,200<CR>
*RX_BUSY Specifies the output to operate and channel busy level for the configured channel. First parameter is the output to operate (from 1-8). The second parameter is the signal level from 0 to -130 (in dBm). If the signal strength on the receiving channel is above this configured value, the channel will be considered to be busy. Transmissions will not be possible if the channel is considered to be busy. After a period of 5 seconds of the channel being busy, the transmitter will transmit anyway. In this example the channel will be considered busy if signal strength is above -80dBm. Typical usage:
*RX_BUSY=1,-80<CR>
Note: If the TReX continually reports BUSY, issue the command *RSSI<CR> to view the current noise floor and adjust the busy level appropriately. WTE Limited, 2018 Christchurch New Zealand Page 72 of 158 TReX User Manual v2.14 Firmware Store Forward Commands Store forward operation is when the unit is used to listen to transmissions in the area, decode the messages and retransmit again to provide greater coverage than would normally be possible. Note: In order to forward messages the decoded message CAP codes must fall within the configured CAP ranges.
*STORE_FWD Configures the store forward operation, this command uses 2 parameters as follows:
*STORE_FWD=XX,YY<CR>
Where:
XX is the Store Forward Operation YY is the Duplicate Reject Operation Store Forward Operation:
Setting to 0 disables the feature. The non zero value set is the delay in 100ms steps after each transmission. This delay allows time for any downstream forwarding equipment to clear the message. Max store forward delay is 24 seconds. All messages are immediately queued for transmission, and up to 5 messages may be retransmitted after the store forward delay. Duplicate Reject Operation:
Setting to 0 disables the feature, otherwise this is the number of seconds to reject identical messages for up to 60 seconds. Duplicate rejection operates only on messages decoded for forwarding. This means that receiving of duplicate messages is not prevented (nor the transmission of same messages resulting from a protocol command), but when used as part of a simple store forward system re-queueing of messages can be controlled. Duplicate reject only tests the previous 5 messages in the historic transmit queue. For example, to configure to use a 2 second clearing delay after each transmission and 10 second message duplicate reject:
*STORE_FWD=20,10<CR>
WTE Limited, 2018 Christchurch New Zealand Page 73 of 158 TReX User Manual v2.14 Firmware Input Commands The input commands allow messages to be configured for transmission when changing state. Debouncing (how long an input is settled before acting on the new level) can be configured with the number of times to transmit the input message. Note: Even if an input is configured to transmit a certain number of messages, should the input level change before all messages are transmitted, then the remaining transmissions will be cancelled. Please refer to Input Output Hardware Connection section on this manual for examples of how to connect the input and output pins on the TReX.
*IN_CONFIG_L Specifies all input Low configuration parameters. Inputs are triggered by connecting the input to ground for a time exceeding the specified debounce period. The input message is configured using the *IN_MSG_L command. Usage is as follows:
*IN_CONFIG_L=I:N,D,R Where:
I = The input to configure (1-11 valid). Input 9 is the VIN input, 10 is ADC 1 and 11 is ADC 2.
: = the colon character :
N = number of transmissions (0 = no transmissions, 9 is max tx count)
, = the comma character , D = debounce in 100 ms steps (from 0-255)
, = the comma character , R = time in seconds between retransmissions. Example. Configure input 1 to send two message after input is debounced by 300 milliseconds and repeat/retransmit this message 4 times. Typical usage:
*IN_CONFIG_L=1:2,3,4<CR>
*IN_CONFIG_H Specifies all input High configuration parameters. Inputs are triggered by moving the input to a high state or released from GND for a time exceeding the specified debounce period. The input message is configured using the *IN_MSG_H command. Usage is as follows:
*IN_CONFIG_H=I:N,D,R WTE Limited, 2018 Christchurch New Zealand Page 74 of 158 TReX User Manual v2.14 Firmware Where:
I = The input to configure (1-11 valid). Input 9 is the VIN input, 10 is ADC 1 and 11 is ADC 2.
: = the colon character :
N = number of transmissions (0 = no transmissions, 9 is max transmission count)
, = the comma character , D = debounce in 100 ms steps (from 0-255)
, = the comma character , R = time in seconds between retransmissions. Typical usage:
*IN_CONFIG_H=1:1,10,15<CR>
*IN_MSG_L Specifies the low level message that will be transmitted if configured. Input messages must always use WT Protocol. Typical usage: .
*IN_MSG_L=1:WT1234560A10 IN_1_LOW<CR>
*IN_MSG_H Specifies the high level message that will be transmitted if configured. Input messages must always use WT Protocol. Typical usage:
*IN_MSG_H=1:WT1234560A10 IN_1_HIGH<CR>
*IN_ANALOG Specifies the high and low ADC count thresholds for an analog input to be considered a digital HIGH or digital LOW. When these thresholds are exceeded, then programmed messages for HIGH and LOW levels can be transmitted. All ADC counts are the SCALED ADC counts.
*IN_ANALOG=1H,1L,2H,2L,3H,3L Where:
1H = Input voltage high (x10) 1L = Input voltage low (x10) 2H = ADC1 voltage high ADC count 2L = ADC1 voltage low ADC count 3H = ADC2 voltage high ADC count WTE Limited, 2018 Christchurch New Zealand Page 75 of 158 3L = ADC2 voltage low ADC count Typical usage:
*IN_ANALOG=138,114,200,100,500,400<CR>
TReX User Manual v2.14 Firmware WTE Limited, 2018 Christchurch New Zealand Page 76 of 158 TReX User Manual v2.14 Firmware Output Commands The output commands allow the GPIO pins to be configured as outputs or inputs. Following configuration of the pins as outputs, they are controlled using the WTE Output Control Protocol. Note: Please refer to Input Output Hardware Connection section on this manual for examples of how to connect the input and output pins on the TReX board.
*OUT_CONFIG Specifies all output configuration items, usage as follows:
*OUT_CONFIG=O:E,T <CR>
Where:
O = The output to configure (1-2 valid)
: = the character :
E = 1 to enable the set GPIO pin to an output. T = time for output to close for in 100ms steps. E.g. 100 is 10 seconds. Max value is 32000. Setting to 0 disables the timer and output is latched indefinitely. Typical usage:
*IN_CONFIG_L=1:1,10<CR>
*UNIT_ID Specifies the output unit ID
*UNIT_ID=XX<CR>
where:
XX are any characters (up to 12 either numeric or alphanumeric) that are used to uniquely address each TReX when used in conjunction with the WTE Output Control Protocol. By default this ID is 01, allowing numeric paging to be used to transmit messages. Typical usage:
*UNIT_ID=Unit-A<CR>
WTE Limited, 2018 Christchurch New Zealand Page 77 of 158 TReX User Manual v2.14 Firmware System Commands
*TREX_LANG Specifies the language used by the unit
*TREX_LANG=X where:
0 = English 1 = Spanish 2 = French Typical usage:
*TREX_LANG=0<CR>
*TREX_BACKLIGHT Specifies the time in seconds which the display LED backlight will be lit for after a key is pressed. Setting to 0 disables. Setting to 30 enables permanently. Typical usage:
*TREX_BACKLIGHT=10<CR>
*TREX_SOUND Controls sounds made when a key is pressed or when a message is received that results in an ALERT being raised. Typical usage:
*TREX_SOUND=1<CR>
*TREX_RS232_BAUD Sets the serial baud rate of the RS232 port. Typical usage:
*TREX_RS232_BAUD=9600<CR>
WTE Limited, 2018 Christchurch New Zealand Page 78 of 158 TReX User Manual v2.14 Firmware
*TREX_RS422_BAUD Sets the serial baud rate of the RS422 port. Typical usage:
*TREX_RS422_BAUD=4800<CR>
*TREX_ALERT_OUT Sets the output that will operate when a message is received that results in an ALERT being raised. Setting to 0 disables the ALERT output. Accepts outputs 1-8. Typical usage:
*TREX_ALERT_OUT=0<CR>
*TREX_ALERT Sets the output to operate (0-8) and the time in seconds between sounding the buzzer (if TREX_SOUND has been set to 1). Alerting will continue until a key is pressed to acknowledge the ALERT. . Setting the output to 0 does not disable the alert. Typical usage:
*TREX_ALERT=1,60<CR>
*TREX_FILTERS Sets the message filters that are in use when a message is received.
*TREX_FILTERS =I,E,A<CR>
where:
I is set to 1 if the INCL.TXT filter is to be used. E is set to 1 if the EXCL.TXT filter is to be used. A is set to 1 if the ALERT.TXT filter is to be used. See FILTERS for details of use. Typical usage:
*TREX_FILTERS =0,0,0<CR>
WTE Limited, 2018 Christchurch New Zealand Page 79 of 158 TReX User Manual v2.14 Firmware
*TREX_TELEMETRY Sets all parameters necessary to enable either the point to point serial link or back to back mirror mode of operation.
*TREX_TELEMETRY=M,R,A,B,C where:
M is telemetry mode of operation 0 = DISABLED, 1 = SERIAL_LINK, 2 = IO_MIRROR, 3 = SCADA_SLAVE, 4 = SCADA_MASTER R is the number of remote TReX units when the telemetry mode is SCADA_MASTER (valid 0-10) A is the local unit ID (from 1-255). B is the remote unit ID (from 1-255). C is how long in seconds before sending all input information again. Typical usage:
*TREX_TELEMETRY=0,0,1,2,10<CR>
*TREX_SCREEN Sets the default main screen and the page for that main screen. On start-up the first screen viewed is this screen. After a period of keypress inactivity, this is the return screen. This is shown here only for completeness. Typically this would only be set through the MENU system, and has no relevance when the TReX is being serially controlled.
*TREX_SCREEN=X,Y where:
X = main screen Y = page for that main screen. Typical usage:
*TREX_SCREEN=0,0<CR>
*TREX_PIN Sets the Personal Identification Number, which can be used to unlock the unit. The PIN prevents accidental mis-configuration or changes by unauthorised users. WTE Limited, 2018 Christchurch New Zealand Page 80 of 158 TReX User Manual v2.14 Firmware
*TREX_PIN=nnnn where:
nnnn = 4 digit PIN number. Typical usage:
*TREX_PIN=0000<CR>
*TREX_AN_CAL Sets parameters used to calibrate the analog outputs and inputs. See DAC and ADC CAL Sub-
Menus for more information.
*TREX_DAC_CAL=AA,BB,CC,DD where:
AA = DAC1 minimum count. Default 0. BB = DAC1 maximum count. Default 1023. CC = DAC2 minimum count. Default 0. DD = DAC2 maximum count. Default 1023. EE = ADC1 minimum count. Default 0. FF = ADC1 maximum count. Default 1023. GG = ADC2 minimum count. Default 0. HH = ADC2 maximum count. Default 1023. Typical usage:
*TREX_AN_CAL=0,1023,0,1023,0,1023,0,1023,
*TREX_MISMATCH Sets parameters that control the antenna mismatch detection feature. When an antenna is missing, damaged or mismatched, the following may be observed; The current may increase, the RF power detected may increase/decrease through reflection, or the output power may be low. Should any of these be detected, the mismatch output can be configured to operate.
*TREX_MISMATCH=AA,BB,CC,DD,MM where:
AA = the output to operate on mismatch detection. BB = the max forward power permitted (ADC count). CC = the max system current permitted in mA. WTE Limited, 2018 Christchurch New Zealand Page 81 of 158 TReX User Manual v2.14 Firmware DD = the number of seconds to operate the output. MM = the min permitted output power (ADC count). Typical usage:
*TREX_MISMATCH=2,300,1500,5,200<CR>
WTE Limited, 2018 Christchurch New Zealand Page 82 of 158 TReX User Manual v2.14 Firmware TCP-IP Commands
*IP_ENABLE Enable/disable the Ethernet subsystem of the radio. Use:
1 to enable WEB only. 2 to enable WEB plus TCP SERVER 3 to enable WEB plus TCP CLIENT 4 to enable TCP SERVER only. 5 to enable TCP CLIENT only. Typical usage:
*IP_ENABLE=1<CR>
*IP_HOST Configures the name used by the DNS server to allocate name to IP translation on the network. Typical usage:
*IP_HOST=WTE-TReX<CR>
*IP_ADD Specifies the default IP number set to be used by the network. Typical usage:
*IP_ADD=192.168.1.20<CR>
*IP_PORT Specifies TCP Port used by the TCP server and client. Port for web configuration is fixed at 80. Typical usage:
*IP_PORT=5080<CR>
WTE Limited, 2018 Christchurch New Zealand Page 83 of 158 TReX User Manual v2.14 Firmware
*IP_MASK Specifies default network mask number. Typical usage:
*IP_MASK=255.255.255.0<CR>
*IP_GATE Specifies the address used for the gateway. Typical usage:
*IP_GATE=192.168.1.1<CR>
*IP_DNS Specifies the IP number used to connect to the DNS server, up to 2 DNS servers can be set.
*IP_DNS=aaa.bbb.ccc.ddd,eee.fff.ggg.hhh where:
aaa.bbb.ccc.ddd = first DNS server IP, eee.fff.ggg.hhh = second DNS server IP Typical usage:
*IP_DNS=192.168.1.1,0.0.0.0<CR>
Note: The IPs are separated by the use a , (COMMA)
*IP_MAC Returns the MAC (Media Access Code) number of the unit, this is a readable field only. Typical usage:
*IP_MAC?<CR>
Typical output:
*IP_MAC=60AD45676000<CR>
WTE Limited, 2018 Christchurch New Zealand Page 84 of 158 TReX User Manual v2.14 Firmware Protocols Serial input into and out of the TReX can be formatted differently by selecting an appropriate protocol handler. WT Protocol The WT Protocol is the default protocol used by WTE products. It allows for a variety of over the air transport methods (such as POCSAG paging) to be used and a variety of baud rates. The WT Protocol also supports the use of macros to embed variable information in messages such as system voltage, time etc. see Variable Content Macros. Transmitting Messages Message format:
WTNNNNNNNABC<SPACE>MMMMM<CR>
Where:
WT are the 2 characters WT NNNNNNN are 7 ASCII digits from 0000000-9999999 A is the Transport method:
A = POCSAG Alpha N= POCSAG Numeric W= POCSAG WTE (WTE 8 bit format allowing all 8 bit characters to be transmitted) S= Message Payload sent directly to serial port without transmission. See note Serial Only Transport of Messages. B is the Level 1-9. Note that POCSAG only supports levels 1-4 which is the same as the Beep Level. C is the data rate (specified in channel width ranges):
25 kHz Channel Space Settings 0 = 512 Baud 2 Level FSK 1 = 1200 Baud 2 Level FSK 2 = 1600 Baud 2 Level FSK 3 = 2400 Baud 2 Level FSK 4 = 3200 Baud 4 Level GFSK 5 = 4800 Baud 2 Level GFSK 6 = 9600 Baud 2 Level GFSK 7 = 9600 Baud 4 Level GFSK 8 = 16000 Baud 4 Level GFSK WTE Limited, 2018 Christchurch New Zealand Page 85 of 158 TReX User Manual v2.14 Firmware 9 = 32000 Baud 4 Level GFSK 12.5 kHz Channel Space Settings A = 512 Baud 2 Level FSK B = 1200 2 Level FSK C = 2400 2 Level FSK D = 4800 2 Level GFSK E = 9600 2 Level GFSK F = 9600 4 Level GFSK G = 16000 4 Level GFSK 6.25 kHz Channel Space Settings a = 512 Baud 2 Level FSK b = 1200 2 Level GFSK c = 2400 2 Level GFSK d = 4800 4 Level GFSK NOTE: Although the protocol supports the following modulation types and channel spacings, the supplied WTE product may only support a subset of these modulation rates (determined by regional restrictions).
<SPACE> is a single space character. MMM... is the payload, up to 240 characters.
<CR> is the carriage return character Example:
To send a 512 baud alpha message to 1234567 level 1 with payload of TEST WT1234567A10<SPACE>TEST<CR>
After processing/transmitting responds with:
WT[TTT,NNN]<CR>
where:
TTT is the ticket ID that was assigned to the transmission. Rotates from 999 to 0. NNN is the number of characters from W until, but not including <CR> , the test message above results in the following response WT[123,017]<CR>
If a user specified response is required this response can be changed. To change the sent WTE Limited, 2018 Christchurch New Zealand Page 86 of 158 TReX User Manual v2.14 Firmware response to Page Sent a leading * character must be used in the PROTOCOL->SENT RESP config item. e.g. *Page Sent. Received Messages All messages received come out via the serial port as configured in by the *RX_PROTO setting:
If *RX_PROTO=WTE then the output will look like:
WT1234567A10<SPACE>TEST<CR>
The exact same format allows units to be connected together, or protocols to be converted from one type to another. Serial Only Transport of Messages There is sometimes a need to only send WT protocol messages out a serial port and not transmitted on a particular event. For example, if an input changes state, it might be desirable to send a message out the serial port to control another piece of equipment, or. it might be useful to use the periodic message to send a health check message out the serial port once every 5 seconds. Receiver only TReX units use this method to output messages. The transport type S has been assigned for this purpose. Example:
To send the message INPUT 1 LOW out the serial port when input 1 moves low program the input 1 low message with:
WT1234567S10<SPACE>INPUT 1 LOW<CR>
All aspects of the message are ignored except for the message payload INPUT 1 LOW. WTE Limited, 2018 Christchurch New Zealand Page 87 of 158 TReX User Manual v2.14 Firmware Variable Content Macros WT Protocol can use several macro tags to display variable content. This may be useful as part of a periodic message for example to report battery voltage or IO conditions. Any number of macros can be used in any location of the message until the max message length has been reached. Macro Tag Description Example Output
**01
**02
**03
**04
**05
**06 Auto Incremented Ticket ID
(3 digits rotating) Time/Date Digital IO Analog IO System Voltage Temperature (Digital, RF degrees Celsius) 123 23:34 01/02 I:11110000--- O:1111000000 ADC:1023,1003 DAC:1023,1003 12.1 23.4, 44.5 Example:
To transmit the system voltage when input 1 goes low, program the input 1 low message with:
WT1234567A10<SPACE>INPUT 1 **05V<CR>
The message that will be transmitted and then received will look approximately like:
INPUT 1 12.1V WTE Limited, 2018 Christchurch New Zealand Page 88 of 158 TReX User Manual v2.14 Firmware Modbus The TReX supports both RTU and TCP modbus protocol options. These are well established and defined protocols used primarily in SCADA control and monitoring applications. These Modbus protocols can be used over any of the RS232, RS422, RS485 and Ethernet interfaces. Baud-rates, IP configuration and Modbus specific configuration items are through:
MENU->PROTOCOL->MODBUS. This is an optional feature. Note that the Modbus TCP protocol by default uses port 502. This is not a firm requirement, and this can be changed to another port. The TReX defaults to port 5080. Modbus RTU The Modbus RTU protocol, as well as the TCP extension, are well documented in the specifications which are available at http://www.modbus.org, a website established by the Modbus Organization for supporting and organizing the Modbus protocol. Only the use of the protocol is documented here. The first byte of the Modbus RTU protocol is a single byte Modbus Slave ID. The TReX uses the Slave ID as the Unit ID when the Modbus TCP protocol is used. These ID codes allow multiple units to be addressed, or in the case of Modbus TCP, multiple units to be used on the same IP address. Modbus TCP The Modbus/TCP extension includes 6 additional bytes to the original Modbus RTU protocol, which allows for transport over the TCP/IP layers. Only a single TCP connection is permitted at any one time. The TReX sends these 6 bytes PLUS the entire RTU protocol payload (except the last two CRC bytes). The first byte of the RTU protocol is the unit ID (usually described as part of the Modbus MBAP header) Function Codes Listed are the supported Modbus function codes. All function codes not specified will return a Modbus standard error response. The TReX supports 1 MASTER plus up to 10 SLAVES wirelessly connected. Note: in the following mapping, provision has been allowed for multiple SLAVE units. The first single register (and in the case of discrete I/O, 8 registers) are for the MASTER unit, and following registers are for the installed SLAVE units in the system. WTE Limited, 2018 Christchurch New Zealand Page 89 of 158 TReX User Manual v2.14 Firmware Valid Address Range 0x0000 - 0x0057 Registers 1 to 88 Function Code Description 01 Read Coils Code to read the 8 TReX digital outputs (MASTER TReX plus up to 10 wireless SLAVE TReX units) 02- Read Digital Inputs Code to read the up to 88 TReX digital inputs (MASTER TReX plus up to 10 wireless SLAVE TReX units) 0x0000 - 0x0057 10001 to 10088 03- Read Holding Registers 04 Read Input Registers 05 Write Single Coil 06 Write Single Register 15 Write Multiple Coils 16- Write Multiple Registers Read DAC1 registers Read DAC2 registers 0x0000 0x000A 0x0100 - 0x010A 40001 to 40011 40257 to 40267 Code to read the ADC1 Code to read the ADC 2 Code to read Temperature Reserved Code to read BattV Read Link Status Count Code to write to the 8 TReX outputs(MASTER TReX plus up to 10 wireless SLAVE TReX units) Code to write DAC1 Code to write DAC2 Special Command Code Code to write to up to 8 outputs at once
(MASTER TReX plus up to 10 wireless SLAVE TReX units) Message TX Buffer (see below) 0x0000 0x000A 0x0100 0x010A 0x0200 0x020A 0x0300 0x030A 0x0400 0x040A 0x0500 0x050A 0x0000 - 0x0057 30001 to 30011 30257 to 30267 30513 to 30523 30769 to 30779 31025 to 31035 31281 to 31291 1 to 88 0x0000 0x000A 0x0100 0x010A 0x0200 0x020A 0x0000 - 0x0057 40001 to 40011 40257 to 40267 40513 to 40523 1 to 88 0x0300 0x03FA 40769 to 40892 Modbus Mapping Table Base Address Num Registers 1 10001 30001 30257 30513 88 88 11 11 11 Description Digital Out (discrete) Digital In (discrete) ADC 1 (raw count 0-1023) ADC 2(raw count 0-1023 ) Temperature 1(signed short x 10) R/W R/W R R R R Bits 1 1 16 16 16 WTE Limited, 2018 Christchurch New Zealand Page 90 of 158 TReX User Manual v2.14 Firmware 30769 31025 40001 40257 40513 11 11 11 11 11 Status(signed short x 10) Battery(signed short x 10) DAC 1 (value from 0-1023) DAC 2 (value from 0-1023) Special Function Commands 1 Reboot Unit 2 Request Slave I/O to be returned to Master. R R R/W R/W W 16 16 16 16 2 40769 125 Message Tx Buffer (variable len up to 250 bytes) W 16 Message Tx Buffer (On Request):
The TReX is a Modbus capable paging transmitter. This means that not only can the generic third party SCADA application control and monitor IO using standard Modbus commands, but the SCADA application can also send paging messages using the WT Protocol. This allows the SCADA application to directly message to pager, send information to devices such as LED signs or to output serial data from any TReX unit. In order to send a pager message, the SCADA application should send content such as WT1234560A10 Test Message to Modbus address 0x300 and function code 16. The message must conform to the documented WT Protocol. WTE Limited, 2018 Christchurch New Zealand Page 91 of 158 TReX User Manual v2.14 Firmware Custom Protocol This protocol allows many existing protocols provided by other vendors to be supported by the parsing of fields based on configuration (without new firmware being required). The custom protocol takes as a starting point various default values that may or may not be replaced depending on how the unit is configured:
- Preconfigured default cap code (*TX_CAP=1234567).
- Preconfigured default level or priority (*TX_LEVEL=0).
- Preconfigured default baud rate (*TX_BAUD=2400_25).
- Preconfigured default transport mode (*TX_MODE=POCSAG_A). For each of these fields a command is set to specify the content (up to 9 fields)
*CUST_FIELD
*CUST_FIELD=F:S,L,match,I, T Where:
F is the field number (1-9 permitted)
: is the colon character :
S is the start index in message (from 0-255). This field rule will start looking at this index in the incoming message (index is 0 based).
, is the comma character , L is the length of the field to parse (0-255. If 0 is specified, then parsing will continue until the first non printable character is found). match is any string that should be matched in the incoming message. This may or may not be used as described below (not all field attribute types inspect this field) I is the case insensitive flag. I means that the match string previously described is case insensitive (test will match on incoming messages with tESt and TEST). meaning that the match field is case sensitive. T is field attribute as described below (e.g. MATCH, CAP etc.). Each field may have any of the following attributes (displayed in the command *LIST). MATCH - the field must exactly match the specified match string. Message is rejected if not found. WTE Limited, 2018 Christchurch New Zealand Page 92 of 158 TReX User Manual v2.14 Firmware CAP - the field is parsed into the cap code to use (match string ignored). LEVEL - the field is parsed into the priority of beep level (match string ignored). MSG - the field is parsed into the message field (match string ignored). BAUD_512 - the field is parsed and if matches 512 baud is set for outgoing message. BAUD_1200 - the field is parsed and if matches 1200 baud is set for outgoing message. MODE_A - the field is parsed and if matches, Transport method (POCSAG Alphanumeric) is set for outgoing message. MODE_N - the field is parsed and if matches, Transport method (POCSAG Numeric) is set for outgoing message. UNUSED - the field is unused. Full Example:
To support a serial input of:
ET1234567-1-TEST<CR>
In this example (from an unspecified third party) the number 1234567 is a POCSAG CAP code. The 1 between the - characters specifies the beep level and TEST is the message payload. If the ET at the start is in capitals, then the message is transmitted at 512 baud. If the message starts with et then the message is transmitted at 1200 baud. Implementation:
Set match field 1, start index 0 for a length of 2 characters. If the match string is found, then BAUD rate of 1200 is used.
*CUST_FIELD=1:0,2,et,, BAUD_1200<CR>
Set match field 2, start index 0 for a length of 2 characters. If the match string is found, then BAUD rate of 512 is used.
*CUST_FIELD=2:0,2,ET,,BAUD_512<CR>
Set match field 3, start index 2 for a length of 7 characters. This field is parsed into the capcode
*CUST_FIELD=3:2,7,,,CAP<CR>
Set match field 4, start index 10 for a length of 1 characters. This field is parsed into the priority
*CUST_FIELD=4:10,1,,,LEVEL<CR>
Set match field 5, start index 12 for a length of 0 characters. This field is parsed into the message payload. Note that a length of 0 means that parsing will continue until a non printable character is found. WTE Limited, 2018 Christchurch New Zealand Page 93 of 158 TReX User Manual v2.14 Firmware
*CUST_FIELD=5:12,0,,,MSG<CR>
To make more robust, further checks on the input can be made in this case to look for -
characters (at index 9 and 11):
Set match field 6, start at index 9 for a length of 1 character. If the - string is not matched, the entire message will be considered invalid and discarded.
*CUST_FIELD=6:9,1,-,,MATCH<CR>
Set match field 7, start at index 11 for a length of 1 character. If the - string is not matched, the entire message will be considered invalid and discarded.
*CUST_FIELD=7:11,1,-,,MATCH<CR>
Say how many fields are in use. UNUSED ignores all following fields. Note that field 9 and 10 in this example do not need to be set to UNUSED, but only done here to reduce confusion.
*CUST_FIELD=8:0,0,,,UNUSED<CR>
*CUST_FIELD=9:0,0,,,UNUSED<CR>
*CUST_FIELD=10:0,0,,,UNUSED<CR>
Full Example of Minimum Configuration:
If default fields are configured (setting cap code, level etc.), then for the same input of:
ET1234567-1-TEST<CR>
The very least configuration required to transmit is (ignoring all parameters except the message payload to transmit):
Set match field 1, start index 12. Length is 0 so the MSG is parsed until the first non printable character is seen. This field is parsed into the MSG field that is transmitted.
*CUST_FIELD=1:12,0,,,MSG<CR>
*CUST_FIELD=2:0,0,,,UNUSED<CR>
WTE Limited, 2018 Christchurch New Zealand Page 94 of 158 TReX User Manual v2.14 Firmware Custom Protocol Response This section defines the serial output from the TReX back to the user when a message has been accepted for transmission. Responds with up to 3 custom response fields followed by a <CR>
Supported attributes are:
CONST (includes in the response exactly the content configured between ). CAP (includes the CAP code of the transmitted message in the response). LEVEL(includes the beep level of the transmitted message in the response). MSG (includes the message payload transmitted in the response) Example 1:
e.g. if response of SENT<CR> is desired
*CUST_RESP=1:SENT,CONST<CR>
*CUST_RESP=2:,UNUSED<CR>
*CUST_RESP=3:,UNUSED<CR>
Example 2:
e.g. if response of JX1234567<CR> is desired (where 1234567 is the CAP code of the transmitted message and JX are the characters JX).
*CUST_RESP=1:JX,CONST<CR>
*CUST_RESP=2:,CAP<CR>
*CUST_RESP=3:,UNUSED<CR>
Custom Protocol Output The custom protocol output is used to quickly format the output of any message decoded across the air. The application for this is to allow the serial output to match an input that is expected for a third party connected system. WTE Limited, 2018 Christchurch New Zealand Page 95 of 158 TReX User Manual v2.14 Firmware
*CUST_OUTPUT
*CUST_OUTPUT is the start point to construct the serial output message. This command holds constant text that may then be modified by the CUST_FIELDS commands if required. For example, when an over the air message is received the serial output may need to be forwarded to another providers equipment. Imagine that the required output to drive this equipment is AABBCCCCMMM. Full understanding of the providers third party protocol format is not required, only that MMM is the message. The TReX custom output is accordingly set to AABBCCCCMMM and the CUSTOM_FIELD commands are then used to insert/replace the decoded message into the position of MMM. If all CUSTOM_FIELDS are UNUSED then the output will ALWAYS be the constant AABBCCCCMMM. Consider an example where the decoded over the air message will have a CAP code of 1234567, LEVEL of 1 and message body of TEST. It is required in this example that output should have the format ET1234567-1-TEST. First configure the expected message format as follows:
*CUST_OUTPUT=ET1111111-2-TEST<CR>
With the *CUST_OUTPUT set the TReX can now be configured to replace part of this text with the text received from an over the air message received. This example was also used/described previously.
*CUST_FIELD=3:2,7,,,CAP<CR>
*CUST_FIELD=4:10,1,,,LEVEL<CR>
*CUST_FIELD=5:12,0,,,MSG<CR>
All the over the air received messages will now be output serially with the required/configured format. Please contact customer support at WTE Limited if assistance is required configuring the CUSTOM protocol (info@wte.co.nz). WTE Limited can also implement support for your existing protocols through negotiation. WTE Limited, 2018 Christchurch New Zealand Page 96 of 158 TReX User Manual v2.14 Firmware RAW Protocol The Raw protocol uses all default settings to determine the data rate, transport method, cap code etc. This protocol is the protocol used when using a point to point serial link. Default transmission settings are configured with the commands:
*TX_BAUD
*TX_CAP
*TX_LEVEL In addition, the following commands are used with RAW protocol:
*RAW_TIMEOUT Specifies the time of inactivity in 25ms steps before sending all stored data (max 255), example for a timeout of 100mS:
Typical usage:
*RAW_TIMEOUT=4<CR>
*RAW_LEN Specifies the number of characters to transmit at once. Messages exceeding the length can still be sent, but there will be a small delay between each transmission. Transmission delays may be longer than expected if the TReX determines that the channel is busy. Typical usage:
*RAW_LEN=100<CR>
*RAW_END Specifies a character that results in immediate transmission, or displayed after reception (0 if unused). Decimal value of ASCII character. Typical usage:.
*RAW_END=13<CR>
This means transmit immediately after the carriage return character is seen. Also after decoding each message, the carriage return character is also displayed.
*RAW_CONFIG Specifies all RAW protocol parameters. Parameter 1 specifies the time of inactivity in 25ms steps before sending all stored data
(max 255). Parameter 2 specifies the number of characters to transmit at once. Messages exceeding WTE Limited, 2018 Christchurch New Zealand Page 97 of 158 TReX User Manual v2.14 Firmware the length can still be sent, but there will be a small delay between each transmission. Transmission delays may be longer than expected if the TReX determines that the channel is busy. Parameter 3 specifies a character that results in immediate transmission (0 if unused). Decimal value of ASCII character, Typical usage:
*RAW_CONFIG=4,100,13<CR>
WTE Limited, 2018 Christchurch New Zealand Page 98 of 158 TReX User Manual v2.14 Firmware SCADA Support SCADA (Supervisory Control And Data Acquisition) is a term used widely in many industries relating to monitoring and control systems. This section deals with the integration of the TReX into a SCADA system. This is an optional feature, that requires a feature key to be purchased. Terminology SCADA application:
This is a software package that is used to control and monitor devices. This could be free open source packages such as Rapid SCADA or openSCADA. Alternatively, this could be industry standard applications such as WonderWare or LabView. SCADA system:
This is a system comprising of one or many TReX units monitoring equipment that the TReX units are connected to. This includes also the SCADA application. MASTER:
This is the unit that is connected through Ethernet or another interface to a SCADA monitoring application. This master unit can now control and hold the details of up to 10 TReX slaves. Input and output status of all units can be immediately requested or modified directly by the SCADA application. To set the TReX as a master set MENU->TELEMETRY->MODE to SCADA_MASTER. SLAVE:
These TReX units are directly controlled by the TReX master. The slaves primary function is to report input changes and/or operate its outputs upon a master request. There may be up to 10 slave units, all located in different locations around a site, all monitoring and controlling different aspects of the SCADA system. To set the TReX as a slave set MENU->TELEMETRY->MODE to SCADA_SLAVE. WTE Limited, 2018 Christchurch New Zealand Page 99 of 158 TReX User Manual v2.14 Firmware Working Example As a simple working example shown below, web content is being served to a PC and mobile devices using the open source application RapidSCADA. SCADA applications have the advantages to provide a means to notify through; email, paging messages, SMS or to generate alarms of critical system events. WTE Limited, 2018 Christchurch New Zealand Page 100 of 158 TReX User Manual v2.14 Firmware SCADA System Single TReX Configuration This is a system that requires no expansion through use of SLAVE units. WTE Limited, 2018 Christchurch New Zealand Page 101 of 158 Unit Configuration TReX User Manual v2.14 Firmware Since this system configuration is only for a single TReX unit, the LOCAL ID and REMOTE ID fields are not used and can be set to anything. The MODBUS ID can be any value from 0-
127 (except 42 or 87). MENU->PROTOCOL->MODBUS is used to configure the key SCADA parameters, such as unit ID and the protocol. Typically, if an Ethernet connection is used, the TCP protocol will be used. See MODBUS Protocol for more Modbus information. WTE Limited, 2018 Christchurch New Zealand Page 102 of 158 TReX User Manual v2.14 Firmware SCADA System Multiple TReX Configuration Up to 10 wireless SLAVES can be controlled by a MASTER. A SCADA application will be able to monitor and control all TReX IO on the MASTER and SLAVE TReX units. Simple Example A remote station controlling two separate pump stations, where the Remote Station has a TReX units connected to a SCADA system and the Pump Stations may have several pumps and other I/O devices connected. Here the Remote Station is configured as MASTER and the Pump Station are configured as SLAVE units. Example Configuration:
Remote Station has a LOCAL ID configured to be 01. Pump Station 1 SCADA_SLAVE has a LOCAL ID of 02, Pump Station 2 SCADA_SLAVE has a LOCAL ID of 03, All Units have been configured to refresh I/O each 30 seconds (REFRESH TIME). Note: Refreshing of SCADA status is immediate on any digital input change or any analogue input that changes by more than ADC counts configured in DELTA ADC TX. WTE Limited, 2018 Christchurch New Zealand Page 103 of 158 TReX User Manual v2.14 Firmware Units Configuration Remote Station Configuration The LOCAL ID must be configured to a system unique value (default 01). REMOTE ID must be configured to the ID of the first SLAVE LOCAL ID. MODBUS ID can be any value from 0-127 (except 42 or 87). WTE Limited, 2018 Christchurch New Zealand Page 104 of 158 TReX User Manual v2.14 Firmware Pump Station 1 Configuration Pump Station 2 Configuration The MASTER unit has configured REMOTES to a value of 2 (meaning there are 2 SLAVE units). Note that each SLAVE must start at the REMOTE ID configured on the MASTER, and each SLAVE in the system must be consecutively numbered. The SLAVE configuration is unique in that both the LOCAL ID and REMOTE ID need to be the same. In this configuration, the MASTER unit requires these settings in order to identify the SLAVE unit messages. The SCADA application will report inputs 1-8 to be from Remote Station, inputs 9-16 from Pump Station 1 and inputs 17-24 from Pump Station 2. See Modbus Protocol for more information. WTE Limited, 2018 Christchurch New Zealand Page 105 of 158 TReX User Manual v2.14 Firmware Viewing Multiple TReX Unit IO on the MASTER Unit. The MASTER on the IO screens can view all system inputs and outputs without the need for a SCADA application. This is useful for debugging and installation. Shown in this case is the number 01, followed by 069, where01 in this case is the UNIT ID in the system. The 069 is a link fail counter used to determine loss of communication for a unit. This number is reset whenever a new message is decoded from a SLAVE unit. Pressing the DOWN button will cycle through all the remote UNIT IDs in the system, displaying all system IO, link states, temperatures and battery voltages. WTE Limited, 2018 Christchurch New Zealand Page 106 of 158 TReX User Manual v2.14 Firmware SCADA Communication Between MASTER and SLAVE All communication between the MASTER and SLAVE units can be viewed on the RX and TX screens. These messages are of little application to the user, and documented here purely for clarity of function and debugging if required. These messages are a variation of the WTE Output Control Protocol. There are however special codes used reserved for internal use only. Messages from MASTER to SLAVE:
Code U1 U2 U3 U4 Messages from SLAVE to MASTER:
Code U1 U2 U3 U4 U5 U6 U7 U8 Description DAC 1 Control Value DAC 2 Control Value Digital Output Bitmap Special Slave Commands Description DAC 1 Control Value DAC 2 Control Value Digital Output Bitmap Digital Input Bitmap ADC 1 Value ADC 2 Value Temperature * 10 Battery V * 10 WTE Limited, 2018 Christchurch New Zealand Page 107 of 158 TReX User Manual v2.14 Firmware IO Mirror Operation The IO MIRROR is the simplest self managed telemetry mode that mirrors the inputs of one TReX unit to the outputs of another TReX unit. SCADA monitoring and control is not possible in this mode of operation (see SCADA Configuration and Operation). This mode is intended for a simple system that allows remote outputs to be controlled and inputs monitored without any supervising equipment. When TELEMETRY->MODE is set to IO MIRROR the small T icon is displayed in the title bar. The IO MIRROR mode can map a single TReX unit to another TReX unit or to many selectively configured TReX units. When enabled, the REMOTE ID device outputs are mirrored to the state of LOCAL ID device inputs. In order for a REMOTE ID device to have its outputs changed through the MIRROR MODE, the output must be configured to be TELEMETRY. It is possible to restrict outputs(s) that are updated by DISABLING outputs on the REMOTE ID device. REMOTE ID devices are automatically controlled using the WTE output control protocol. When there is any input change, or an analog input changes by more than a configured threshold amount, there is an immediate transmission that updates a REMOTE ID device outputs. A periodic refresh time can also be configured to ensure that outputs and inputs remain synchronised. On a REMOTE ID device inputs may optionally be tied to outputs to allow the actual remote output state to be displayed on the originating ID unit. Mirrored INPUTS use the same TX DEBOUNCE and TX COUNT configuration items as normal message inputs. To prevent inputs from being mirrored, set the TX COUNT to 0. In some cases multiple transmissions may be desired. The default configuration is to transmit an input after being debounced for 200mS. WTE Limited, 2018 Christchurch New Zealand Page 108 of 158 TReX User Manual v2.14 Firmware When IO MIRROR is enabled, configurable messages cannot be transmitted from inputs. If mirroring of some inputs and messages transmitted on other inputs is a requirement, this can be achieved by configuring some input message using the WTE output control protocol. After selecting a frequency to transmit on, the default settings will in many cases be enough for the system to be ready to test before deployment. NOTE: Make sure the REMOTE ID of one device matches the LOCAL ID of the other. WTE Limited, 2018 Christchurch New Zealand Page 109 of 158 TReX User Manual v2.14 Firmware Input Handling Note: Please refer to Input Output Hardware Connection section on this manual for examples of how to connect the input and output pins on the TReX board. The TReX supports 8 programmable inputs. Each input can be programmed with a short message up to 50 characters in length. Input messages must always be formatted as WT Protocol. On start-up each input is read. By default only inputs that change from the start-up input state are processed. The expected initial state of each input can be configured, so that on start the input is not in its expected state there can be an immediate transmission. Commands relating to input handling (if preferred, all input options can be configured through the menu system):
*IN_INIT specifies the expected level on start.
*IN_CONFIG_H specifies all input transition to high level configuration parameters.
*IN_CONFIG_L specifies all input transition to low level configuration parameters.
*IN_MSG_H specifies the high level message that will be transmitted if configured.
*IN_MSG_L specifies the low level message that will be transmitted if configured. The *IN_CONFIG_H and *IN_CONFIG_L commands allow the input to specify:
How many messages are transmitted once triggered. The debounce period (how long the input must be in a new state continuously in order to transmit) before the input is triggered. How long to wait until the message is retransmitted. The *IN_MSG_H and *IN_MSG_L commands allow the input to specify the message which will be transmitted when the input is triggered. Full example:
In this example both inputs are configured to transmit only when moving from high to low (no high level transmissions). Transmit 5 times, 10 seconds between each transmission. Debounce period is to be configured to 2 seconds (input must have transitioned from a stable low level to constant high level for two whole seconds). The protocol being used is WT protocol, and the message for each input message is IN 1 LOW and IN 2 LOW. Message is to be transmitted as POCSAG alphanumeric to cap code 1234560, beep level 1 and 512 baud. Both Input 1 and 2 configured to disable all high level processing.
*IN_CONFIG_H=1:0,0,0<CR>
WTE Limited, 2018 Christchurch New Zealand Page 110 of 158 TReX User Manual v2.14 Firmware
*IN_CONFIG_H=2:0,0,0<CR>
Both input 1 and 2 are configured as per the full example details above.
*IN_CONFIG_L=1:5,20,10<CR>
*IN_CONFIG_L=2:5,20,10<CR>
Configured messages to be transmitted once triggered.
*IN_MSG_L=1:WT1234560A10 IN 1 LOW<CR>
*IN_MSG_L=2:WT1234560A10 IN 2 LOW<CR>
High level messages can be set to anything since they are configured not to be used
*IN_MSG_H=1:<CR>
*IN_MSG_H=2:<CR>
For more details on command usage please refer to the Configuration section if required. WTE Limited, 2018 Christchurch New Zealand Page 111 of 158 TReX User Manual v2.14 Firmware Output Handling Note: Please refer to Input Output Hardware Connection section on this manual for examples of how to connect inputs and outputs to the TReX. The TReX supports up to 8 outputs. These outputs can be shared with special output functions such as the LINK FAIL output. Outputs are configured using the commands:
*OUT_CONFIG
*OUT_ID The outputs are controlled through messages received that conform to the WTE output control protocol. WTE Limited, 2018 Christchurch New Zealand Page 112 of 158 TReX User Manual v2.14 Firmware WTE Output Control Protocol Introduction This section describes how to control the outputs of WTE Products via transmission payloads. The WTE protocol needs to be able to switch many outputs on, and many off in a single message. Receivers need to be able to be uniquely addressed, and in a manner that is maintainable. It may be likely that the payload is transmitted as part of a paging payload, such as POCSAG or FLEX, but ultimately the transport method is irrelevant as long as it is capable of transmitting the characters used by the protocol. Once an output has been activated, it will remain in its activated state for its configured period. This may be many seconds, or permanently latched. The control message can be placed in any position in the message payload, and there can be multiple control messages in the same payload. Digital Output Format The payload of a message must fit the following format in order to operate the unit outputs. Note that this description is extended below to describe how this format is extended to also allow control of analog outputs.
[[ID]EEEE-DDDD]
Where:
[ is the character [
] is the character ]
ID is the OUT_ID that has been programmed (e.g 01 or Unit_A). E is the output to enable (1-8 for the TReX). Up to 2 outputs can be specified.
- is the hyphen character - All digits following the - are outputs that are disabled D is the output to disable Examples:
Consider an TReX configured with OUT_ID of Unit_A and both pins configured as outputs:
*OUT_ID=Unit_A<CR>
WTE Limited, 2018 Christchurch New Zealand Page 113 of 158 TReX User Manual v2.14 Firmware
*OUT_CONFIG=1:1,0<CR>
*OUT_CONFIG=2:1,0<CR>
Scenario 1: To turn output 1 ON and turn OFF output 2;
Message payload:
[[Unit_A]1-2]
Scenario 2: To turn output 2 ON and turn OFF output 1;
Message payload:
[[Unit_A]2-1]
Scenario 3: To turn output 1 and 2 ON;
Message payload:
[[Unit_A]12-]
Scenario 4: To turn output 1 and 2 OFF;
Message payload:
[[Unit_A]-12]
Consider that we have several TReX Units and each one is configured with a different OUT_ID; Unit_A, Unit_B and Unit_C Scenario 5: To turn output 1 and 2 ON in the Unit_A:
Message payload:
[[Unit_A]12-]
Scenario 6: We want:
to turn output 1 and 2 ON in the Unit_A, to turn output 1 ON and turn OFF output 2 on the Unit_B, turn OFF output1 and 2 on the Unit_C;
Message payload:
[[Unit_A]12-] [[Unit_B]1-2] [[Unit_C]-12]
Analog & Digital Output Format The WTE output control protocol allows the direct control of analog outputs. WTE Limited, 2018 Christchurch New Zealand Page 114 of 158 TReX User Manual v2.14 Firmware
[[ID]UZ[AA]CCC-OOOO]
Where:
[ is the character [
] is the character ]
ID is the UNIT_ID that must match the TReX to be controlled.. U is the character U and is used to mark that an analog or special output follows Z is the analog output (1-2). 3 is used to write a digital output bitmap. C is output to close (1-8). Up to 8 outputs can be specified.
- is the character -
O is the output to open AA is the value to set an analog output to (0-1023). When a digital output bitmap value is used this value can be a value from 0-255. When an analog output is set to higher than 1023, the value 1023 is used. When square brackets are after an analog output specifier (U), then the value specified is the DAC value to set. Note that both a digital output and analog output can have the same output number. When analog outputs are controlled they must always be before any digital outputs. Example 1:
Unit configured to have WTE_ID of UNIT-1. Digital outputs 2 and 4 are to be set, and output 1 cleared. Analog Output 2 is to have the DAC set a value of 927 Message payload:
[[UNIT-1]U2[927]24-1]
Example 2:
Unit configured to have WTE_ID of 01. Analog Output 1 is to have the DAC set a value of 18, analog output 2 is to have a DAC value of 145. Message payload:
[[01]U1[18]U2[145]]
Notes:
The unit will only process the Output Control Protocol for the unit configured in the OUT_ID and will ignore the other Output Control Protocol contained in the message Additional security to prevent false activation can be achieved through CAP restriction via the RX_RANGE and/or a more complex OUT_ID. WTE Limited, 2018 Christchurch New Zealand Page 115 of 158 TReX User Manual v2.14 Firmware WTE Ack and Confirm Protocol Introduction This section describes how to use this protocol to invoke automatic acknowledging and optionally manual confirmation of messages sent/received. This protocol can also be used to message TReX units to display confirmation prompts. The use of this protocol is the heart of making two-way paging or messaging possible. Monitoring equipment can make decisions based on acknowledge responses whether to retransmit or notify a communications link issue. Acknowledgements can be either transmitted or sent through a TCP/IP connection. A typical application for a confirmation request would be an emergency communications room messaging several ambulances with TReX units fitted. The message would provide an on-
screen prompt requesting attendance to an event. Any ambulance can then accept the message, and details of the attending vehicle would then be sent to the communications room. The WTE Ack and Confirm Protocol can be embedded into the payload of any message. Typically the protocol message would be attached to the end of a message, so that paging messages would display normally for typical users. Note: In order for a TReX unit to acknowledge any message, the receiving TReX RIC codes used must fall within allowed normal RX receive ranges. Protocol Usage
-[TTT-A-XXX]
where:
- is the character '-' (marks the start of the ticket ID and ACK Mode)
[ is the character '['
TTT is a 3 digit ticket id A is the ACK Mode 1 = acknowledge required 2 = acknowledge and confirmation required 3 = confirmation without acknowledgement (when sent to many stations.)
- is the character - marking the start of the optional confirmation title. XXX is the optional confirm title (e.g. "Accept?"). Not specifying this field results in default of "CONFIRM". This field is only meaningful when ACK mode is 2 or 3. Max length is 14 WTE Limited, 2018 Christchurch New Zealand Page 116 of 158 characters.
] is the character ']'
TReX User Manual v2.14 Firmware Responses are all transmitted using the default settings for modulation type and protocol. The payload is also sent directly out the serial port and TCP sockets for when acknowledgement is required via IP. Typical Operation The base-station TReX sends single messages, or many batched together as required. The transmitter can send an auto incremented ticket ID, or the ticket ID can be manually selected as part of the Acknowledge and Confirm Protocol. Using WT Protocol allows the use of the Variable Content Macro **01 to be used to transmit with an automatically incrementing ticket ID. Receiving TReX units can acknowledge multiple messages if messages have been received in a batch. e.g. The remote TReX unit receives 3 messages all to be acknowledged (ticket IDs 345, 346 and 347). The following is transmitted. ACK[345,346,347]
Upon reception of any message requiring confirmation, the TReX shifts from any screen currently on, and does not allow leaving of the confirmation message screen until the message has either been accepted or rejected. Any messages received while waiting for confirmation will be logged and can be inspected at a later time. Example 1:
Message payload to have delivery acknowledged is transmitted. Message Payload:
Bob, go to Pukeko Place urgently.-[345-1]<CR>
Remote TReX responds with:
ACK[345]
WTE Limited, 2018 Christchurch New Zealand Page 117 of 158 TReX User Manual v2.14 Firmware Example 2:
Message payload to have delivery acknowledged and confirmed is transmitted. All units, go to Pukeko Place urgently.-[347-2-Turnout Y/N?]<CR>
The remote TReX unit immediately displays:
Remote TReX immediately responds with:
ACK[347]
If message has been accepted (by pressing the square ENTER/ACCEPT button) remote TReX responds with:
ACC[347-Unit 41]
Note that the Unit 41in the confirmation response is the TReX programmed unit ID. Example 3:
Message is transmitted from base station using WT Protocol together with the Acknowledge and Confirm Protocol added to the end to the message. WT1234567A10 HEART ATTACK, 45 YO MALE, 12 PUKEKO PL.-[**01-3-ATTEND?]<CR>
Note: The WT Protocol must be used to automatically expand the **01 macro to an automatically incremented ticket id. The remote TReX unit immediately displays:
In this case, the received message has not requested delivery confirmation, only confirmation WTE Limited, 2018 Christchurch New Zealand Page 118 of 158 TReX User Manual v2.14 Firmware of acceptance. Should the user ACCEPT the message to attend, the remote TReX transmits to the base-station the message:
ACC[666-Unit A]
where:
666 is the ticket id.
- is the character -
Unit A is the unit ID programmed through SYSTEM->ID WTE Limited, 2018 Christchurch New Zealand Page 119 of 158 Store Forward Operation TReX User Manual v2.14 Firmware The TReX can operate as a stand-alone repeater to forward paging messages and also extend wireless serial operation. Transmit and receive configuration should be configured to be the same when forwarding messages. *RX_PROTO should equal the *TX_PROTO and *RX_MODE should equal
*TX_MODE. Typically the TReX would be configured as follows:
Delay of 2 second before forwarding, reject duplicate messages for 10 seconds.
*STORE_FWD=20,10<CR>
Ensure all store forward units have RX_RANGES set to allow all possible CAP codes that are of interest to forward. The duplicate reject feature is essential to use when the TReX is been used in a multi-hop store forward system. If this is set to 0, rejection of duplicated messages are not possible, and messages may bounce back and forward between repeaters. The duplicate reject period, if used, ALWAYS must be of a longer duration than the store forward delay for reliable operation. Multiple repeaters can be used, but increase message delivery time. Use of more than a single repeater in a system is generally less than ideal and typically more powerful transmitters should be used if multiple store forward repeaters are required. See the Configuration section on this document for more details on command usage if required. WTE Limited, 2018 Christchurch New Zealand Page 120 of 158 TReX User Manual v2.14 Firmware Installation The TReX should be situated away from direct sunlight, extreme vibration and heat sources, and high power transmission sources. An external antenna correctly designed to operate at your intended frequency of operation will result in best performance. Dual VHF/UHF antennas may operate acceptably for your requirements. Do not situate the antenna immediately next to the antenna of a high power transmission source position greater than 2 M from any other antenna. Mount the external antenna with as much elevation as possible for best results (see Antenna Elevation below). Maximum tolerated input power into the RF connector is 17 dBm. Levels above this will destroy the receiver RF input and invalidate the unit warranty. Cables Supplied By default NO cables are supplied on purchase. Because there are so many possible frequencies and variations in installation an antenna is NOT supplied by default. If an antenna is supplied, it will be a generic variety that will not perform as well as an antenna produced for the intended frequency of operation, or a high gain externally mounted type. If cables are to be supplied, this must be ordered at time of purchase. WTE Limited, 2018 Christchurch New Zealand Page 121 of 158 TReX User Manual v2.14 Firmware Connecting to the TReX The minimum required connections for a usable system:
1. Connection to a 50 ohm antenna constructed for the frequency of interest. Mismatched antennas may result in increased current draw and reduced power output. 2. 13.8V, 3A supply connected to the power terminals WTE Limited, 2018 Christchurch New Zealand Page 122 of 158 Connector Pin descriptions TReX User Manual v2.14 Firmware RHS (Right Panel) RF BNC connector (50 ohms) USB Mini type B connector Input/Output Connector:
Inputs/Outputs Pin Number 1 2 3 4 5 6 7 8 9 10 11 12 Description Input Digital 1 Input Digital 2 Input Digital 3 Input Analog 1 Input Analog 2 GND GND Output Analog 1 Output Analog 2 Output Digital 1 Output Digital 2 Output Digital 3 WTE Limited, 2018 Christchurch New Zealand Page 123 of 158 I/O Expansion Connector:
TReX User Manual v2.14 Firmware I/O Expansion
(DB25) Pin Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Description Input Digital 1 Input Digital 3 Input Digital 5 Input Digital 7 Input Analog 1 GND Reserved - Do NOT Connect GND Output Digital 1 Output Digital 3 Output Digital 5 Output Digital 7 Output Analog 1 Input Digital 2 Input Digital 4 Input Digital 6 Input Digital 8 Input Analog 2 GND GND Output Digital 2 Output Digital 4 Output Digital 6 Output Digital 8 Output Analog 2 WTE Limited, 2018 Christchurch New Zealand Page 124 of 158 LHS (Left Panel) TReX User Manual v2.14 Firmware Serial Connector:
Serial Connector Pin Number 1 2 3 4 5 6 7 Power Connector:
Power Connector Pin Number 1 2 3 Description RS422 RX+ (IN+) RS422 RX- (IN-) RS422 TX- (OUT-) RS422 TX+ (OUT+) RS232 TX RS232 RX Ground (GND) Description Ground (GND)
+13.8V Not Connected (N.C.) WTE Limited, 2018 Christchurch New Zealand Page 125 of 158 Ethernet Connector:
TReX User Manual v2.14 Firmware Connector Pin Number Description 1 2 3 4 5 6 7 8 TX+
TX-
RX+
NC NC RX-
NC NC Note: pins: 4 and 5 are connected to ground via a 75R resistor 7 and 8 are connected to ground via a 75R resistor Do not connect a Power over Ethernet (PoE) connection to the TReX Ethernet port as this will result in damage. WTE Limited, 2018 Christchurch New Zealand Page 126 of 158 TReX User Manual v2.14 Firmware Input Output Hardware Connection Examples of how to connect external devices to the TReX input/output pins. Inputs WTE Limited, 2018 Christchurch New Zealand Page 127 of 158 TReX User Manual v2.14 Firmware Outputs Care must be taken to ensure the sinking output current does not exceed 100mA. When using inductive loads, such as relay coils, flyback diodes must be fitted to prevent damage to the TReX. VDD is voltage source externally provided between 5 and 24VDC depending on the control application. WTE Limited, 2018 Christchurch New Zealand Page 128 of 158 TReX User Manual v2.14 Firmware Serial Connections RS-232 Illustration 1: TReX RS-232 DB9 Connector as DTE Illustration 2: TReX RS-232 DB9 Connector as DCE WTE Limited, 2018 Christchurch New Zealand Page 129 of 158 TReX User Manual v2.14 Firmware RS-422/RS-485 RS-422 and RS-485 use a differential electrical signal, as opposed to unbalanced signals referenced to ground as used by RS-232. Differential transmission uses two lines each for transmit and receive signals which results in greater noise immunity and longer distances between devices. These advantages make RS-422/RS-485 a better fit for industrial applications. RS-422 is point to point interface that allows for up to 10 receivers but only a single transmitter. This would be a common serial interface for NMEA devices all sharing GPS data from a single GPS receiver for example. RS-485 is a multipoint interface that allows each device to be a transmitter and also a receiver. This interface also allows for more devices to be connected on a common serial bus. Because each device on the same bus can transmit, each device must be capable of setting all transmit lines to a high impedance state when not in use to ensure that all devices have the ability to transmit. RS-485 interfaces can be presented as 4 or 2 wires. When there are 2 wires required, the RS-485 device must also be able to isolate its own receiver when transmitting to prevent looping data back to itself. The TReX satisfies the requirements for both 4 and 2 wire RS-485 communications. The TReX will also be able to operate on a RS-422 bus. WTE Limited, 2018 Christchurch New Zealand Page 130 of 158 Point To Point Connection TReX User Manual v2.14 Firmware Illustration 3: TReX RS-422 Point to Point Connection Multi-Point Connection Illustration 4: TReX RS-485/RS-422 Multi-Point Note: this configuration only applies if driving less than 10 listeners/receivers when using RS-
422 devices or less than 32 devices for RS-485 devices. WTE Limited, 2018 Christchurch New Zealand Page 131 of 158 2 Wire Connection TReX User Manual v2.14 Firmware Illustration 5: TReX RS-485 2 Wire Multi-Point Note: the TReX must have wire links fitted as shown in order to operate correctly in this configuration. Bus Terminating Resistor RS422/RS485 may require the fitting of a terminating resistor. The purpose of termination is to match the impedance of a transmission line to the hardware impedance of the interface it is connected to. There is more than one way to add termination to an RS485/422 serial connection. The most commonly used is DC Termination, accomplished by attaching a resistor between the signal lines on the extreme ends of the transmission line. The rule of thumb for termination is:
If the propagation delay of the data line is much less than one bit (pulse) width, termination is not needed. This assumes reflections will damp out in several trips back and forth on the data line. Typically for slow speeds of 9600bps or below, no termination resistor is required. If termination is required a resistor value of 120 or greater should be used, and no more than 2 termination resistors should be used, one at each end of the RS422 transmission line. Do not use termination resistors with a value of less than 90. WTE Limited, 2018 Christchurch New Zealand Page 132 of 158 There are many online references available to calculate these resistors if required. TReX User Manual v2.14 Firmware WTE Limited, 2018 Christchurch New Zealand Page 133 of 158 TReX User Manual v2.14 Firmware RF Connections A 50 ohm matched load must be fitted to the TReX antenna port. Note: Earth the antenna tower, feeders and lightning protection devices in accordance with the appropriate local and national standards. Use grounding kits as specified or supplied by the coaxial cable manufacturer to properly ground or bond the cable outer.
!CAUTION When the TReX is operating, there is RF energy radiated from the antenna. Do not stand in front of the antenna while the radio is operating (see the RF Exposure Warning) Lightning will destroy electronic equipment.
!CAUTION To avoid this risk, install primary lightning protection devices on any interfaces that are reticulated in the local cable network. You should also install a coaxial surge suppressor on the radio antenna port. WTE Limited, 2018 Christchurch New Zealand Page 134 of 158 TReX User Manual v2.14 Firmware Power Connections Power to the TReX is achieved via the power connector as described in the section 16.3.Connecting to the TReX|
EXPLOSION HAZARD
!WARNING TReX was NOT designed to operate and/or be connected to voltages above what has been specified. Failure to follow these instructions can result in death or serious injury WTE Limited, 2018 Christchurch New Zealand Page 135 of 158 TReX User Manual v2.14 Firmware Ethernet Interface The TReX supports a 10/100 Base-T Ethernet connection. To simplify network setup, the TReX supports auto-negotiation and auto-sensing MDI/MDIX crossover. General Interface Cabling Bandwidth allocation Ethernet mode Diagnostics Green LED Orange LED RJ45 CAT-5/6 UTP, supports auto MDIX (Standard Ethernet) The Ethernet capacity maximum is determined by the available radio link capacity. 10Base-T or 100Base-TX Full duplex or half duplex
(Auto-negotiating and auto-
sensing) Off: No data present on the interface. On: Data present on the interface. Off: no Ethernet connection On: Ethernet signal received WTE Limited, 2018 Christchurch New Zealand Page 136 of 158 TReX User Manual v2.14 Firmware TReX Firmware Upgrade In order to update the TReX primary firmware you will need:
1. The WTE Firmware Update Tool (available from http://www.wte.co.nz or provided if required from info@wte.co.nz). 2. One USB mini B cable. 3. An appropriate encrypted hex file supplied by WTE Limited. Note: Attempting to load a hex file not intended for use with the TReX will render the TReX inoperable. Uploading firmware should only be performed if instructed to do so by WTE Limited or an authorised agent. Firmware Upgrade Utility This bootloader software has been customised by WTE to simplify the firmware replacement process for the TReX, This application automatically handles erasing and verifying of uploaded firmware. This utility does not perform any decryption function (decryption is carried out by the TReX itself). WTE Limited, 2018 Christchurch New Zealand Page 137 of 158 TReX User Manual v2.14 Firmware Upgrade Process 1. Run the application WTE-UBL.exe this is the WTE Firmware Update Tool as shown above. 2. BEFORE applying power to the TReX, press the UP button, and HOLD the button down. 3. Apply power to the TReX. 4. The TReX backlight will flash on and off (approximately once every second) keep the UP button pressed. You now have 10 seconds to press the PC application Connect button on the WTE Firmware Update Tool before the TReX exits the bootloader mode of operation. 5. Press the WTE Firmware Update Tool Connect button. If connected, the PC application will display the message saying Device Connected. The TReX backlight will now stay constantly on. 6. You can now RELEASE the TReX UP button. 7. On the PC application press the Load Hex File button. 8. Select the supplied TReX hex file. NOTE: the firmware used must MATCH the TReX receiver variant. A TReX can only be used with TReX encrypted firmware. Failure to comply will leave the device inoperable. 9. Press the WTE Firmware Update Tool Program button. 10. Wait for the WTE Firmware Update Tool to indicate that programming has been completed. 11. When programming is complete press the Run Button, or remove power to the TReX and apply power again. 12. If successful the TReX will start normally when power is applied. If the TReX does not correctly start, then repeat the procedure. WTE Limited, 2018 Christchurch New Zealand Page 138 of 158 TReX User Manual v2.14 Firmware Physical Dimensions TReX physical dimensions are 104mm x 130.5mm x 40mm (Length x Width x Height) Weight: 550 grams WTE Limited, 2018 Christchurch New Zealand Page 139 of 158 TReX User Manual v2.14 Firmware Mounting Hardware The TReX enclosure was designed to be mounted via:
DIN Rails Left or Right M4 nuts and bolts channels Top or Bottom M4 nuts and bolts channels Supplied nut slot inserts. Please look the following images and descriptions to correctly mount the TReX radio DIN Rail Inbuilt into the TReX custom extrusion there is a DIN rail slot (patent pending) for easy snap fit DIN rail mounting. After location on the DIN rail, 2.5mm locking pins may optionally be fitted from each end plate if desired (a 2.5mm split pin is a perfect fit). WTE Limited, 2018 Christchurch New Zealand Page 140 of 158 TReX User Manual v2.14 Firmware Mounting Channels The TReX has channel strips on the front, rear, top and bottom. In order to access the front, top and bottom channels (less common mounting option) the end plate on the power cable side will need first to be removed using a hex key. Mounting from the rear does not require the removal of the end plate. The mounting channel allows an M4 bolt head or M4 nut to lock inside. If an M4 nut is used inside the channels (instead of a M4 bolt head) attention must be taken to NOT use a bolt or screw longer than the channels depth. Not paying attention to this detail may result in damage to the TReX and invalidate the product warranty. TOP Mount The flush mount option is suitable for an installation such as onto the front panel of a case or cabinet. WTE Limited, 2018 Christchurch New Zealand Page 141 of 158 SIDE Mount TReX User Manual v2.14 Firmware WTE Limited, 2018 Christchurch New Zealand Page 142 of 158 Bottom Mount TReX User Manual v2.14 Firmware WTE Limited, 2018 Christchurch New Zealand Page 143 of 158 TReX User Manual v2.14 Firmware Mount Bolts Dimensions Both top and bottom are symmetric as are the left and right sides of the TReX radio, this allows a wide range of mounting configurations. The channels space from centre to centre in the top and bottom of the radio is 117.40mm Dimension are in millimetres WTE Limited, 2018 Christchurch New Zealand Page 144 of 158 Top and Bottom Drilling Template TReX User Manual v2.14 Firmware Note:
All dimensions are in millimetres. The drilling template will need to be scaled depending on your printer settings. WTE Limited, 2018 Christchurch New Zealand Page 145 of 158 Side Drilling Template TReX User Manual v2.14 Firmware Note:
All dimensions are in millimetres. The drilling template will need to be scaled depending on your printer settings. Depending on installation, not all mounting points may be required. WTE Limited, 2018 Christchurch New Zealand Page 146 of 158 TReX User Manual v2.14 Firmware Omni or Directional Antenna It is common in radio systems to consider an omni or directional antenna. Both have their advantages and disadvantages as follows. If in doubt, consult a local antenna specialist who will be able to advise and construct an antenna best suited to your application. Omni antenna Omni antenna have the advantage of transmitting and receiving signals equally well in all horizontal directions. This means that if the transmitter or the receiver moves, the antenna will not need to be changed/adjusted to compensate. This is the common antenna used in cellular phones and handhelds radios. Directional antenna Directional antenna have the ability to focus energy in a particular direction. This advantage increasing the maximum distance between transmitter and receiver units. Since the signals are focused/concentrated into a direction it also increase the overall performance of the system. This is mainly used for fixed transmitter and receiver locations. WTE Limited, 2018 Christchurch New Zealand Page 147 of 158 TReX User Manual v2.14 Firmware Antenna Elevation As with any radio receiver, raising the height of either the transmitter or receiver antenna will result in dramatic improvements to the maximum possible receive distance. Although a high power transmission will increase distance, the installed height of the receiver antenna is the key to a high performing system. When close to the ground the major obstacle to overcome, since radio signals are mainly line of sight, is the curvature of the earth. The typical distance to expect can be approximately calculated as follows:
D= 2r 0hf 6076.10 Where:
D is the distance to the horizon in NM, r0 hf 0 is the mean radius of the earth (3440.1 NM), is the height of your antenna,
(0.8279) accounts for terrestrial refraction. This formula can be simplified to:
Where:
d = range in nautical miles, hf
= the height of your antenna in feet. d=1.17hf Working with metric units this formula becomes:
km=2.170.305hm Where:
km = range in kilometres, hm = the height of your antenna in metres. Therefore:
WTE Limited, 2018 Christchurch New Zealand Page 148 of 158 TReX User Manual v2.14 Firmware Antenna Elevation (metres) Clear Line of Sight Distance (km) 1 5 100 1.2 2.7 12 The Antenna Elevation is the combined elevation of both the transmitter and the receiver
(transmitter at 1m and receiver at 9m will behave similarly as the transmitter at 5m and receiver at 5m. Changes in power level will help to address a less than ideal antenna or poor line of sight conditions. When line of sight or elevation is poor, the range can also be approximately doubled with every 6dB increase in link budget (either increase in TX power, or increase in RX sensitivity). From testing, these ranges can be expected from a 20dBm transmitter at the indicated elevation. The TReX has an output power of 36dBm (4W).
(credit to www.offshoreblue.com for some range calculation details) WTE Limited, 2018 Christchurch New Zealand Page 149 of 158 Disclaimer TReX User Manual v2.14 Firmware THE RESPONSIBILITY LIES COMPLETELY ON THE USER TO ENSURE THAT THIS DEVICE IS TESTED, THROUGH METHODS THAT ARE APPROPRIATE, TO CONFIRM THAT ALL SYSTEM COMPONENTS (THAT THIS DEVICE AND PC SOFTWARE MAY BE PART OF) ARE WORKING CORRECTLY. This document has been prepared in good faith and produced to assist in the use of this product, however WTE Limited reserves the right to modify, add or remove features without notice. FLEX is a trademark of Motorola, Inc. This unit does not transmit any information in the FLEX format. When product is supplied, it is the user who is responsible for payment of any customs fees/taxes that are imposed on importation. Please note that the maximum permitted transmit power level may vary from country to country. It is the users responsibility to ensure local regulations are adhered to. No User-Serviceable Components. There are no user-serviceable components within the radio RoHS and WEEE Compliance TReX is fully compliant with the European Commissions RoHS (Restriction of Certain Hazardous Substances in Electrical and Electronic Equipment) and WEEE (Waste Electrical and Electronic Equipment) environmental directives. Restriction of hazardous substances (RoHS) The RoHS Directive prohibits the sale in the European Union of electronic equipment containing these hazardous substances: lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyls (PBBs), and polybrominated diphenyl ethers (PBDEs). End-of-life recycling programme (WEEE) The WEEE Directive concerns the recovery, reuse, and recycling of electronic and electrical equipment. Under the Directive, used equipment must be marked, collected separately, and disposed of properly. WTE Limited, 2018 Christchurch New Zealand Page 150 of 158 TReX User Manual v2.14 Firmware Manufacturing marking and labels TReX serial number can found on the unit, also serial number and model information are displayed on start-up or accessible via:
MENU->SYSTEM->FACTORY. FCC Regulations allow for electronic labelling. FCC details can be found via:
MENU->SYSTEM->REGULATORY
*Note: Publication number 784748-D02, FCC-Part 90 allows for devices with integrated display to not require a printed label on the device holding this information. Maintenance No User-Serviceable Components. Servicing is only to be performed by WTE Limited, or agent appointed by WTE Limited. Servicing outside of the warranty period is at the discretion of WTE Limited. WTE Limited, 2018 Christchurch New Zealand Page 151 of 158 TReX User Manual v2.14 Firmware Product End Of Life It is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help conserve natural resources and help ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling contact your local dealer or city council Please recycle this device responsibly. The TReX has a residual scrap value that includes 400g of Aluminium. WTE Limited, 2018 Christchurch New Zealand Page 152 of 158 TReX User Manual v2.14 Firmware Product Warranty WTE Limited products are warranted for a period of 12 months after purchase date against faulty workmanship or materials. Return the product, all freight paid by the customer and the product will be repaired or replaced. The product warranty will be invalidated through evidence of:
Unauthorised work carried out. Tampering, including evidence of removal of internal electronics from the case. Exposure to impact or excessive vibration. Use or installation outside of the specified operating parameters. Installation in wet or corrosive environments. WTE Limited, 2018 Christchurch New Zealand Page 153 of 158 TReX User Manual v2.14 Firmware Abbreviations and Glossary CAP (CAPCODE) - Channel Access Protocol (CAP) code RIC -(Radio Identification Code) - an address used in the POCSAG protocol for pagers POCSAG (Post Office Code Standardisation Advisory Group)- A standard set of code and signalling formats for radio paging. USB (Universal Serial Bus) - A common interface that enables communication between devices and a host controller such as a personal computer (PC). ASCII American Standard Code for Information Interchange BER Bit Error Rate CBC Cipher Block Chaining DCE Data Communications Equipment DTE Data Radio Equipment EMC Electro-Magnetic Compatibility EMI Electro-Magnetic Interference ESD Electro-Static Discharge ETSI European Telecommunications Standards Institute FW Firmware HW Hardware IP Internet Protocol I/O Input/Output ISP Internet Service Provider kbit/s Kilobits per second kHz Kilohertz LAN Local Area Network LED Light Emitting Diode mA Milliamps MAC Media Access Control Mbit/s Megabits per second MHz Megahertz ms milliseconds PC Personal Computer RF Radio Frequency RoHS Restriction of Hazardous Substances RSSI Received Signal Strength Indication RX Receiver SCADA Supervisory Control and Data Acquisition SWR Standing Wave Ratio TCP/IP Transmission Control Protocol/Internet Protocol TCXO Temperature Compensated Crystal Oscillator TFTP Trivial File Transfer Protocol TMR Trunk Mobile Radio TX Transmitter UTP Unshielded Twisted Pair VDC Volts DC WEEE Waste Electrical and Electronic Equipment WTE Limited, 2018 Christchurch New Zealand Page 154 of 158 TReX User Manual v2.14 Firmware Specifications Transmit and Receive Frequency Range:
421MHz 480MHz Spectrum Analyser (Optional):
Frequency range: 142-175, 350 - 499 MHz RBW: 500Hz, 1kHz and 25kHz Span: 3MHz, 120kHz and 24kHz Continual or peak display. Min signal -120dBm, max signal -10dBm. Input Power accuracy: 421-480MHz +/-2 dB, 142-175MHz -8dB. Supply Voltage Nominal 13.8V. Min 10.8. Max 15.6V. Must be supplied with a DC power lead less than 3m in length in order to comply with ETSI EN 301-489-1. Supply cable should be of a cross sectional area of at least 1mm Operating Current at 13.8V:
Ethernet plus TX standby and RX 240mA RX only - 65mA TX standby plus RX 105mA TX standby (RX disabled) 65mA TX operating at 4W Additional 1.0A (for correctly matched antenna) External fusing should be 2A. 8 optically isolated. To operate pull to ground or may be driven high or low. High level from 5-24V. Low Level less than 1V. 2. 0-16 V. Input impedance approx. 50K. Slope and offset configurable (e.g. to support 1-5V or 1-10V). 8 open drain. Max allowed supply voltage 24V. Max rated current 100mA. Digital outputs are NOT short circuit protected. Analog Outputs:
2. 0-10V (for 12V supply voltage). Output impedance 5 ohms. Max current 30mA. May be configured for 4-20mA operation. Minimum loop resistance 100 ohms, maximum 500 ohms. If loop resistance is too low, a 100 ohm series resistor should be fitted. Configurable. to support 1-5V, 1-10V or non-standard currents up to 30mA. Short circuit protected. Short circuit current approximately 35mA. WTE Limited, 2018 Christchurch New Zealand Page 155 of 158 Digital Inputs:
Analog Inputs:
Digital Outputs:
TReX User Manual v2.14 Firmware Protocols Supported:
Modbus RTU Modbus TCP WTE WTE Custom PET/TAP ESPA 4.4.4 Multitone Ascom TPP TNPP TNPPB-NZFS Scope SAL Input Messages:
Input max configured message length 50 characters Temperature Limits:
Operating -30 to + 55 degrees Celsius ambient. Storage/Transit -70 to +70 degrees Celsius. Fault Reporting:
High/low supply voltage. High temperature. RF Power fault Antenna fault Comms link fail Max Rx Input Power:
17dBm. Direct connection above 17dBm (50mW) will destroy the receiver. Receiver at 450.5MHz, 512 baud 12.5kHz (compliant with EN300113):
Sensitivity: -123dBm. Desensitised at frequency multiples of 26MHz (and within 50kHz). Selectivity @ +/- 1 channel: 61dB Bocking at 1MHz offset: Tolerates -20dBm Co-channel Rejection Ratio: Rejects unwanted signal at -4dB Error Behaviour at high signal levels: Decodes wanted signal at +13dBm. Antenna Connector:
BNC Firmware Field upgradable. Communication Interfaces:
1 x RS232 WTE Limited, 2018 Christchurch New Zealand Page 156 of 158 TReX User Manual v2.14 Firmware 1 x RS422/485 (2 or 4 wire) 1 x Ethernet (TCP/IP) FLEX Decode Support:
Decoding of all Alphanumeric and numeric messages at 1600 baud (2 level only). POCSAG Encode and Decode Support POCSAG 512 either alpha or numeric including batched. POCSAG 1200 either alpha or numeric including batched. POCSAG 2400 either alpha or numeric including batched. POCSAG 4800 either alpha or numeric including batched. POCSAG 9600 either alpha or numeric including batched. USA Model (TReX-460) Modulations Supported:
25kHz Channel Width:
512 baud (FSK), 1200 (FSK), 1600 (FSK), 2400 (GFSK), 3200 (4GFSK), 4800 (2GFSK), 9600
(GFSK), 9600 (4GFSK), 16K (4GFSK), 32K (4GFSK) 12.5kHz Channel Width:
512 baud (FSK), 1200 (FSK), 2400 (GFSK), 4800 (GFSK), 9600 (GFSK), 9600 (4GFSK), 16K
(4GFSK) 6.25kHz Channel Width:
512 baud (FSK), 1200 (GFSK), 2400 (GFSK), 4800 (4GFSK) Europe, AU and NZ Model (TReX-461) Modulations Supported:
25kHz Channel Width:
512 baud (GFSK), 1200 (FSK), 1600 (FSK), 2400 (GFSK), 3200 (4GFSK), 4800 (2GFSK), 9600
(GFSK), 9600 (4GFSK), 16K (4GFSK) 12.5kHz Channel Width:
512 baud (FSK), 1200 (FSK), 2400 (GFSK), 4800 (GFSK), 9600 (4GFSK) 6.25kHz Channel Width:
512 baud (FSK), 1200 (GFSK), 2400 (GFSK), 4800 (4GFSK) Ethernet Connection:
Permitted simultaneous connections = 1. Google Chrome (64 bit Version 72.0.3626.121) or FireFox (64 bit version 65.0.2) web configuration and monitoring. TCP socket (both client and server) for both message protocol support and configuration. Cable length should be less than 3m in length in order to comply with ETSI EN 301-489-1. Mechanical:
Length: 104mm or 125mm including BNC connector Width: 131mm Height: 41mm Weight: 550grams WTE Limited, 2018 Christchurch New Zealand Page 157 of 158 TReX User Manual v2.14 Firmware Mounting:
Rack Wall DIN rail IP rating:
IP51. Environmental:
Operating temperature range: -40 to +70 C (-40 to +158 F) Storage temperature range: -40 to +80 C (-40 to +176 F) Operating humidity: Maximum 95% non-condensing Acoustic noise emission. No emission when sounder is disabled. Maximum sound output from sounder is less than 80dBA. Compliance Standards:
EN 300 113 (base-station and portable/mobile compliant). EN 301 489 EN 60950 + IEC 62368-1 EN 50385 FCC part 90 AS/NZ 4768 Testing Laboratory Base-station and mobile compliant, testing completed 8/2/2019. WTE Limited, 2018 Christchurch New Zealand Page 158 of 158
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2019-05-02 | 421 ~ 480 | TNB - Licensed Non-Broadcast Station Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2019-05-02
|
||||
1 | Applicant's complete, legal business name |
WTE Limited
|
||||
1 | FCC Registration Number (FRN) |
0028225399
|
||||
1 | Physical Address |
1 Pukeko Place
|
||||
1 |
Christchurch, N/A 8062
|
|||||
1 |
New Zealand
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
t******@timcoengr.com
|
||||
1 | TCB Scope |
B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2ASGC
|
||||
1 | Equipment Product Code |
TREX460
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
S******** R****
|
||||
1 | Title |
Mr
|
||||
1 | Telephone Number |
0064-********
|
||||
1 | Fax Number |
0064-********
|
||||
1 |
i******@wte.co.nz
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | TNB - Licensed Non-Broadcast Station Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | UHF Digital Transceiver | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 43 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This product incorporates an integrated antenna with an overall gain of 2.15 dBi. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
EMC Technologies (NZ) Ltd
|
||||
1 | Name |
A**** C******
|
||||
1 | Telephone Number |
+64 9********
|
||||
1 | Fax Number |
+64 9********
|
||||
1 |
a******@emctech.co.nz
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 9 | EF | 421 | 480 | 4 | 0.559 ppm | 6K00F1D | |||||||||||||||||||||||||||||||||
1 | 2 | 9 | EF | 421 | 480 | 4 | 0.559 ppm | 11K2F1D | |||||||||||||||||||||||||||||||||
1 | 3 | 9 | EF | 421 | 480 | 4 | 0.559 ppm | 20K0F1D |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC