MUMU-BPBloodPressureMonitorManualV0.5Page1Upper-armWirelessBloodPressureMonitorUserManualType:MUMU-BP2(Arm-type)ThankyouforchoosingaMUMUproduct,Justincasethatyouarefacinganyproblemswithyourdevice,pleasecontactus:XiamenFirstmedMedicalTechnologyCo.,LTDEastof3rdFloor,No.4ZhonghangjiBuilding,No.1HuliAvenue,HuliDistrict,XiamenServicehotline:4009992781ServiceE-mail:service@mymumu.comwww.mymumu.com MUMU-BPBloodPressureMonitorManualV0.5Page2ContentIntroduction1Preparation1.1Safetyprecautions41.2Compositionofproduct91.3Nameofcomponents101.4Applicationmethodofbloodpressuremonitor132Measuringmethod2.1Mobilesoftwareinstallation152.2Bloodpressuremeasuring162.3HistoricalDataDisplay192.4CloudStorage202.5OtherFunctionsofMobileSoftware213FAQ&Maintenance3.1Q&Aforbloodpressuremeasurement223.2Troubleshooting263.3Maintenanceandstorage283.4Specifications293.5Cleaning303.6Statement313.7WarrantyInformation323.8Symbol37 MUMU-BPBloodPressureMonitorManualV0.5Page3IntroductionThankyouforpurchasingandusingtheseriesproductsofMUMU-BPbloodpressuremonitor.Inordertoensuresafeusageofthisproductandmakeittobeyourbestassistantfordailybloodpressuremanagement,weadviseyoutoreadthismanualcarefullybeforeusingthemonitor.Pleasetakecareoftheattachedwarrantycard.IntendedUseThiscompactandconvenientmonitorisanidealdeviceforpeoplewhoneedtomeasuretheirsystolicanddiastolicbloodpressuresandpulseratefrequently.Itisonlydesignedforadultsuse,andtherangeofthecuffcircumferenceis17cm-42cm(3cuffsizesavailable,pleaserefertothesizeyouchose).AfterinstallationofourmobilesoftwareonyouriOSorAndroidsmartdevices,themonitorwillconnecttoyourdeviceviabluetoothandyoucanmeasurethebloodpressure.Pushabuttononthedevice,thenthemeasurementofbloodpressureandpulsebegins,andtheresultswillbedisplayedonyourdevice.Theresultscanbestoredinyourdeviceoruploadedtothecloudforpermanentstorageandmanagement.Nomatterathomeorintheoffice,youcaneasilyandquicklymeasure,browseandsharethehistoricaldata. MUMU-BPBloodPressureMonitorManualV0.5Page41.1SafetyPrecautionsToassurethecorrectuseoftheproductbasicsafetymeasuresIndicatesapotentiallyhazardoussituationshouldalwaysbefollowedincludingtheprecautionslistedbelow:Sincetheself-judgmentandself-treatmentbasedonthemeasurementresultsaredangerous,pleasefollowthedoctorsinstructions.Readallinformationintheinstructionmanualandanyotherliteratureincludedintheboxbeforeusingtheunit.Self-judgmentmightpossiblyleadtoexacerbationofdiseases.Diabetes,hyperlipidemiaandhighbloodpressure,etc.canexpeditearteriosclerosisandevenleadtoperipheralcirculationdisturbance,etc.Patientswiththesediseasesmighthavevariousmeasuringresultsofupper-armbloodpressure.ItisnotrecommendedforpeoplewithseriousarrhythmiatousethisMUMUBPM-2.Pleasedonotusethemonitorforotherpurposesexceptbloodpressuremeasurement.Pleasedonotdismantleorrepairbyyourself,ormodifythismonitorandcuff. MUMU-BPBloodPressureMonitorManualV0.5Page5Theproductismadeofprecisecomponentsandparts.Itshouldbeavoidedfromhigh/lowtemperature,humidity,directsunlight,vibrationanddustyenvironment.Pleaseusesoftdryclothtocleantheproduct.Donotusediluents,alcohol,gasolineorwetclothtoscrubit.Avoidover-foldingthearmletandover-twistingthegastube(fordesk-typeMUMU-BP1)soastoensuretheservicelifeoftheaccessories.Theoperatorshallnottouchtheoutputofbattery/USBportwhenusingAstheproductandarmletarenotwaterproofing,pleaseavoidrain,sweatorwater.IftheproductisusedclosetoTV,microwaveoven,X-rayorotherdeviceswithstrongelectromagneticfield,theprecisionofmeasurementwillpossiblybeaffected.Theproduct,itscomponentsandparts,andbatteriescannotbediscardedasnormaldomesticwastes.Thelocalapplicablelawsshouldbefollowed.Thisproductappliesonlytoadults.Consultyourdoctorforanyofthefollowingsituations:1.Theapplicationofthecuffoverawoundorinflamedarea. MUMU-BPBloodPressureMonitorManualV0.5Page62.Theapplicationofthecuffonanylimbwithintravascularaccessortherapy,oranarterio-venous(A-V)shunt.3.Theapplicationofthecuffonthearmonthesideofamastectomy.4.Simultaneoususewithothermedicalmonitoringequipmentonthesamelimb.5.Thebloodcirculationoftheuserneedstobechecked.Note:1.ThisMUMU-BP2isdesignedforadultsandshouldneverbeusedoninfants,youngchildren,pregnantorpre-eclampticpatients.2.Pleasedonotsharethecuffwithanyinfectiouspersontoavoidcross-infection.Caution:Theuseriscautionedthatchangesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidtheuser'sauthoritytooperatetheequipment.NOTE:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,uses MUMU-BPBloodPressureMonitorManualV0.5Page7andcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures:--Reorientorrelocatethereceivingantenna.--Increasetheseparationbetweentheequipmentandreceiver.--Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected.--Consultthedealeroranexperiencedradio/TVtechnicianforhelp.FCCRadiationExposureStatement:ThisequipmentcomplieswithFCCradiationexposurelimitssetforthforanuncontrolledenvironment.Thistransmittermustnotbeco-locatedoroperatinginconjunctionwithanyotherantennaortransmitter. MUMU-BPBloodPressureMonitorManualV0.5Page8EMCGuidance1.MEDICALELECTRICALEQUIPMENTneedsspecialprecautionsregardingEMCandneedstobeinstalledandputintoserviceaccordingtotheEMCinformationprovidedintheACCOPANYINGDOCUMENTS2.Wirelesscommunicationsequipmentsuchaswirelesshomenetworkdevice,mobilephones,corelesstelephonesandtheirbasestations,walkie-talkiescanaffectthisequipmentandshouldbekeptatleastadistanced=3,3mawayfromtheequipment.(Note:AsindicatedinTable6ofIEC60601-1-2:2007forMEEQUIPMENT,atypicalcellphonewithamaximumoutputpowerof2Wyieldsd=3,3matanIMMUNITYLEVELof3V/m) MUMU-BPBloodPressureMonitorManualV0.5Page91.2CompositionofproductAllproductshavebeenpackaged.Pleaseopenthepackingcasesandmakesurewhethertheyarecomplete.MUMU-BP2USBCableStorageBag MUMU-BPBloodPressureMonitorManualV0.5Page101.3NameofcomponentsMUMU-BP2 MUMU-BPBloodPressureMonitorManualV0.5Page11Statusofindicatorlight(MUMU-BP1/MUMU-BP2)StatusofpowerlightConnectiontoexternalpowerNon-connectiontoexternalpowerLowbatteryvoltage(lessthan20%offullbattery)RedlightflashingRedlightonBatteryvoltagebetween20%and100%GreenlightflashingGreenlightonFullpower(100%)GreenlightonGreenlightonPoweroffRefertoabovestatusOffStatusofBluetoothindicatorlightConnectiontoexternalpowerNon-connectiontoexternalpowerPoweroffoffWaitingtoconnecttocellphoneBluelightflashingConnectedtocellphoneBluelightonChargingport(MUMU-BP2)ThemonitorhasoneMicroUSBinterfaceforcharging.ItrequiresDC5V/1.0Ainput.Generally,thesmartmobilephonechargerthathasMicroUSBportandDC5V/1.0Aoutputcanbeusedtochargethismonitor.PleaseDONOTusethemonitortomeasureduringcharging.Note:1.Donotchangethebattery.Ifthebatterycannolongerbecharged,pleasecontactcustomerservice.2.Overchargingthebatterymayreduceitslifetime. MUMU-BPBloodPressureMonitorManualV0.5Page123.Donotreplacethebatterybyinadequatelytrainedpersonnelwhichcouldresultinahazardsuchasafireorexplosion.4.IftheACadapterisabnormal,pleasechangetheadapter.5.Themonitor,cable,batteryandcuffmustbedisposedofaccordingtolocalregulationsattheendoftheirusage. MUMU-BPBloodPressureMonitorManualV0.5Page131.4Applicationmethodofbloodpressuremonitor MUMU-BPBloodPressureMonitorManualV0.5Page14 MUMU-BPBloodPressureMonitorManualV0.5Page152.1MobileSoftwareInstallationMUMUsoftwareapplicationhasversionsbothforAndroidandiOSsystems.Userscaninstallviathemethodsbelow.Download:http://www.mymumu.com/index.php/DownloadTwo-dimensionalbarcodedownload:MUMU-BPBloodPressureMonitorManualV0.5Page162.2BloodPressureMeasuringBloodpressuremonitoriscontrolledbythesoftwareapplicationinthephoneandmeasurementresultsarestoredinthephone.Itssuggestedtomeasurethebloodpressureregularlyeveryday,likebothinthemorningandevening.Beforemeasuringbloodpressure1.Avoideating,drinkingalcohol,smoking,exercisingandbathingfor30minutesbeforetakingameasurement.2.Stressraisesbloodpressure.Avoidtakingmeasurementsduringstressfultimes.3.Thecuffcanbeappliedtoyourleftorrightarm.AlwaysmeasureyourbloodpressureonthesameArm.4.Measurementsshouldbetakeninaquietplace.5.Positiontheunitatheartlevelthroughoutthemeasurement.6.Remainstillanddonottalkduringthemeasurement.7.Keeparecordofyourbloodpressureandpulsereadingsforyourphysician.Asinglemeasurementdoesnotprovideanaccurateindicationofyourtruebloodpressure.Youneedtotakeandrecordseveralreadingsoveraperiodoftime.Trytomeasureyourbloodpressureatthesametimeeachdayforconsistency. MUMU-BPBloodPressureMonitorManualV0.5Page178.Wait30~60secondsbetweenmeasurements.Thewaittimeallowsthearteriestoreturntotheconditionpriortotakingthebloodpressuremeasurement.Youmayneedtoincreasethewaittimedependingonyourindividualphysiologicalcharacteristics.PreparationMUMUsoftwareapplicationconnectstoMUMU-BPmonitorviaBluetooth.iPhonesneedtosupportBluetoothLE4.0,andAndroidphonesneedtosupportBluetooth2.1.SwitchonthemonitorOpentheMUMUsoftwareapplicationintheAndroidphoneoriPhoneandenterintothemeasurementwindow.Bindthearmletontothearmcorrectly.Pressthemonitorbuttontoswitchitonwithbluelightflashingandwaitforconnectingtosoftwareapplication. MUMU-BPBloodPressureMonitorManualV0.5Page18StarttomeasurePressmeasurebuttonintheMUMUsoftwareapplicationtostartmeasuringthebloodpressure.Measurementcanbedonerepeatedly.Ifeveryothermeasurementintervalisovertenminutes,themonitorshouldberebooted.TurnofftheUnitPressthepowerbuttonfor3seconds,itcanturnofftheunit.TheunitalsocanpoweroffautomaticallyaftertheBluetoothhasdisconnectedfor2min. MUMU-BPBloodPressureMonitorManualV0.5Page192.3HistoricalDataDisplaySavethemeasurementresultsaftermeasuringthebloodpressure.Youcanviewthehistoricaldatainthedatawindowwithasimpleandcleargraph.Clickthebuttonofsummaryontheleftuppercorner,andyoucanviewthetrendinrecentoneweek,onemonth,threemonthsoroneyear. MUMU-BPBloodPressureMonitorManualV0.5Page202.4CloudStorageInthesettings,youcanlogonbyfamilyaccountandthemeasurementdatacanbeuploadedtothecloudandrealizedatasharingbothoncomputersandcellphones. MUMU-BPBloodPressureMonitorManualV0.5Page212.5OtherFunctionsofMobileSoftwareMeasurementresultsarestoredinthecellphones.Youcanviewthedataingraphsandsharethedata.AccuratemeasurementMedicalmonitormeasuringtechnologyisadoptedtoguaranteeaccuratemeasurement.SmartremindersYoucansetremindersformeasurement.Advisetosetat6-9amand16-18pm.CloudstorageUploadthedataviaBluetooth.Permanentstorageisintheunlimitedcloud.Multi-usersMeasurementdataoffamilyandfriendscansharewitheachother.Real-timesharingYoucangetthesystemnotificationsofyourfamilymembersmeasuringinanotherlocation.HealthservicesAnalyzethemeasurementresultsfreeofchargeandofferadvicesonfoodandhealthcare. MUMU-BPBloodPressureMonitorManualV0.5Page223.1Q&AforBloodPressureMeasurementQ:Whythemeasurementresultathomeislowerthanthatinhospital?APeoplewillgetnervouswhenmeasuringinhospital.Becausepeopleathomeisstableinmood,themeasurementofbloodpressureissometimes20mmHg30mmHglowerthanthatinthehospital.Itsimportanttoknowthenormalbloodpressureathome.AInthecasethatthearmletishigherthantheheartIfthedeskorplatformistoohigh,itwillresultinthepositionofarmlethigherthanheart,andthemeasurementresultswillbelower.Q:Whythemeasurementresultathomeishigherthanthatinhospital?AAreyoutakinghypotensor?Peoplewhotakehypotensorwillhaverelativelyhigherbloodpressurewhenthedrugefficacyloses.Pleasefollowthedoctorsinstructions.AIsthepositionofarmletcorrect?Whenthelocationofarmletiswrong,itcannotcapturethearterysignalandthusthebloodpressuremeasurementishigher.Pleaseconfirmthebluetrianglelocation.AIsthearmlettooloose?Ifthearmletisloose,thepressurecannotbetransferredtotheartery. MUMU-BPBloodPressureMonitorManualV0.5Page23Thusthemeasurementresultsarehigherthantheactualvalue.Thereshouldbenogapbetweenarmandarmlet.AIstheposturecorrect?Bending,crossinglegs,orsittingonsofaorbendingdowntowardsthelowtablewillleadtohighermeasurementresultsbecauseoftheabdominalpressureorarmletlocationlowerthanheart.Q:WhydoIgetdifferentresultsaftereachmeasurement?ADoyoumeasureatthesameperiodeveryday?Measurementaftereventensecondswillhaveadifferentresult.Inordertomanagethebloodpressurecorrectly,pleasemeasureatthesameperiodeveryday.ABloodpressurewillfluctuatebecauseofvariousreasons.Evenathomethefollowingcaseswillleadtodifferentresults.Withinonehourafterhavingdinner;drinkalcohol;havecoffeeorbrowntea;aftertakingacigarette;aftertakingabath;Afterexercises;aftertoilet;talkinthemeasuringprocess;anxiety;Suddentemperaturechange;differentlocationsfromtheusualQ:Whythearmfeelspainfulandnumbwhenbindingthearmlet?AItstemporary.Dontworry.Whenmeasuringbloodpressure,itsnecessarytobindthearmlettighton MUMU-BPBloodPressureMonitorManualV0.5Page24thearmtostopbloodflowtemporarily.Thusthearmmightfeelpainfulornumb.Aftertakingoffthearmletitwillgetbetterquickly.ADoyouhavebloodcongestionwhenmeasuringconstantly?Thefingertipsmighthavebloodcongestionduetopressureonthearm.Ifso,loosethearmletandraisethehandsoverthehead.Clenchandstretchthehandsrepeatedlyfor15timesthenthebloodcongestionwillbegone.Q:Whenisthebesttimeformeasuringbloodpressure?AThebesttimeis6-9amor16-18pm.Ifmeasuringinthemorning,pleasemeasurewithinonehouraftergettingup,andafterurinatingandbeforethebreakfast(iftakinghypotensor,beforeit).Ifatothertime,itsbettertomeasurewhenthebodyandmoodarestable.Moreover,itsadvisedtomeasureinthesameperiodeveryday.Q:Arethereanytipsformanagingbloodpressureathome?AApartfromrecordingthebloodpressurevalues,itcanalsorecordthemedicinetakingandlivingstatus.Themobilesoftwarecanrecordtheresultsandshowthemingraphforeasiermanagementanddiagnosisbythedoctor.Forthecorrectjudgment,pleasedonotonlyrecordthebloodpressure,butalsotheactual MUMU-BPBloodPressureMonitorManualV0.5Page25conditions,includingtakinghypotensorandlivingstatus.TipsofbloodpressureClassificationstandardofbloodpressureWHOandISHhaveformulatedthebloodpressureclassificationinthegraphbelow.Itsmeasuredinthehospitaloftheupper-armanddifferentages.Theresnodefinitionoflowbloodpressure.But,normallywethinkpeoplewhosehighpressurevalueisnotover100mmHgarelowpressure.AccordingtoWHO/ISHcriterion(1990revisededition)InternationalSocietyofHypertensionNote:Fordetailedtipsofbloodpressure,pleasebrowsethemobilesoftware. MUMU-BPBloodPressureMonitorManualV0.5Page263.2TroubleshootingAbnormalsituationsPossibleCausesSolutionIndicatorlightisnotonafterthebuttonispressedOutofbatteryornobatteryRechargeRedlightflashesafterthebuttonispressedLowbatteryvoltageRechargeCannotconnecttosoftwareafterpressingthebuttonRedlightflashing,thenlowbatteryvoltageRechargeBluelighton,othercellphonesareconnectedPressthebuttonlongtoswitchoffthemonitorandreboot.Bluelightflashing,openthesoftwaretoconnect.Softwareerror,findnomonitorMonitormightbeinsleeporswitchoffautomaticallywithbluelightoffSwitchon,bluelightflashingandopenthesoftwaretoconnect.IfitisiPhone,thehardwareispossibletooold.SupportiPhone4SandlaterphonesandiPads.Abnormalmeasurementresultofbloodpressure(toohighortoolow)Cuffisnotappliedcorrectly.Bindthecuffcorrectly.Talkingormovingarmsduringmeasurement.Retest,stayquietlyanddonotmoveduringmeasurement.Therolled-upclothespressonthearm.Takeofftheclothesandretest.NopressurizingofthemonitorLeakageofcuffChangeanewcuffWrongconnectionofcuffConnectcorrectlyExhaustairtoofastLoosewrappingofthecuffWrapthecufftightly.Ifnot,extrapressureisonthecuffanditsserviceliftwillbeshorter.PoweroffsuddenlyduringpressurizingThemonitorisnotusedforalongtime.Temperaturechangeresultstoentireconsumptionofbattery.Recharge MUMU-BPBloodPressureMonitorManualV0.5Page27Themonitorworkswellandmeasurecorrectly.TheresultsarehigherorlowerthanthatmeasuredinhospitalDifferentresultseverytimeRefertoQ&AOthercasesRebootandretest.Ifitstilldoesntwork,contactthesellerFewcustomerscannotmeasurenormallyduetophysicalchangesinthebody.Inthiscasepleasecontacttheseller. MUMU-BPBloodPressureMonitorManualV0.5Page283.3MaintenanceandStoragePleasefollowthenoticesinthemanualandothercorrectusingways.Ifnot,wewillnotbeartheresponsibility.MaintenancesuggestionsDonotusevolatileoil,diluentsandgasoline,etc.toscrubthemonitor.Donotwashorwetthearmlet.Ifdirtisfoundonthemonitor,pleaseusedrysoftclothafterwringingoutthewaterorneutralsolventasmuchaspossible.StoragesuggestionsDonotstorethemonitorintheplaceslistedbelow:Locationswitheasycontacttowater.Locationswithdirectsunlight,hightemperature,humidity,dust,andcorrosivegases.Slopes,unstablelocationsandplacesthatmightbeimpacted.Locationsclosetomedicinesorcorrosivegases.Ifthemonitorisnotusedforoversixmonths,pleasechargethebatteryto70%or80%firstandcheckifitsnecessarytorechargeeveryhalfyear. MUMU-BPBloodPressureMonitorManualV0.5Page293.4SpecificationProductnameUPPER-ARMWIRELESSBLOODPRESSUREMONITORProductmodelMUMU-BP1/MUMU-BP2DisplayiOS/AndroidsmartphoneMeasuringmethodOscillometricMeasuringrangeCuffpressure0~299mmHg(0kPa~39.9kPa)Pulserate40~200beats/minAccuracyPressure3mmHg(0.4kPa)Pulserate5%InflationtypeautomaticinflationDeflationtypeAutomaticladderdeflationMeasuringtimeUpto120secondsPower3.7V,760mAhPolymerrechargeablebatteryAutomaticpower-offPowershutoffautomaticallyaftertheBluetoothhasdisconnectedfor2min.ChargingPower5V/1.0AOperatingcondition5to4030%to85%RH,nocondensation;AtmosphericPressure:700to1060hPaAltitude:notexceed3000mStorageandtransportcondition-20to60,10%to95%RH,nocondensation;AtmosphericPressure:700to1060hPaWeight220g(MUMU-BP2)includingthebatteryMachinesizeapprox.130mm*45mm*30mm(MUMU-BP2)Cuffcircumferenceapprox.220mm~320mmPleasecontactsalesstaffforspecialcircumferenceAccessoryArmletusbcableinstructionsNote:Thespecificationissubjecttochangewithoutnotice. MUMU-BPBloodPressureMonitorManualV0.5Page303.5CleaningCleaning1.Whentheproductcoversdust,useacleandusterclothtogentlywipethedustaway.2.Whencleaningtheproductenclosureandcuff,donotusehardobjectsoraerosolcleaners,pleaseusethecleanclothtoclean.3.Cleantheproductandcuffeveryweekoreverytwoweeksbasedontheoperatingenvironment.4.Donotwetthecufforattempttocleanthecuffwithwater.Caution:Pleaseturnoffthemachineandcutoffthepowerbeforedoingthecleaning. MUMU-BPBloodPressureMonitorManualV0.5Page313.6Statement1TheunitsatisfiestherequirementsofEN60601-1MedicalelectricalequipmentPart1:Generalrequirementsforbasicsafetyandessentialperformance;EN60601-1-2:MedicalelectricalequipmentPart1-2:GeneralrequirementsforbasicsafetyandessentialperformanceCollateralstandard:ElectromagneticcompatibilityRequirementsandtests;EN1060-1:Non-invasivesphygmomanometersPart1:Generalrequirements;EN1060-3:Non-invasivesphygmomanometersPart3:Supplementaryrequirementsforelectro-mechanicalbloodpressuremeasuringsystem.EN1060-4Non-invasivesphygmomanometersPart4:Testprocedurestodeterminetheoverallsystemaccuracyofautomatednon-invasivesphygmomanometers.2TheUnitcomplieswithIEC80601-2-30.3TheunithadpassEMCtest.4Theriskofpatientandusercanbeloweredtoacceptablelevel.5Substitutionofacuffdifferentfromthatsuppliedmightresultinmeasurementerror.6Specificationsaresubjecttochangewithoutnoticeduetoimprovementsinperformance.7Theunitmightnotmeetitsperformancespecificationsifstoredorusedoutsidethefollowingspecifiedtemperatureandhumidityranges. MUMU-BPBloodPressureMonitorManualV0.5Page323.7WarrantyInformation1Forrepairunderthiswarranty.Ourauthorizedserviceagentmustbeadvisedofthefaultwithintheperiodofthewarranty.Thiswarrantycoverspartsandlaboronlyundernormaloperations.Atransportationfeeorfreightfeethatmaybeincurredwillbetheowner'sresponsibility.Anydefectresultingfromnaturalcauses,e.g.,flood,hurricaneetc.,isnotwithinthisguarantee.Thisguarantydoesnotcoverdamageincurredby:useoftheunitnotinaccordancewiththeinstructions,accidentaldamage,orbeingtamperedwithorservicedbyunauthorizedserviceagents.2Unitsubjectedtomisuse,abuse,andneglectofthesemanualcontent,non-instructionalpurposes;unauthorizedrepairormodificationswillbeexcludedfromthiswarranty.Thisguaranteespecificallyexcludesexpendablesandconsumables,forexamplebatteries.Allwarrantyclaimsmustbedirectedtothedistributorresponsibleforthesaleofthedevice.Thecontentofthiswarrantyissubjecttochangewithoutfurthernotice.3Periodicalcheck:Sensitivemeasuringdevicesmustbecheckedfromtimetotimeforaccuracyandleakage,wethereforerecommendthattheperformanceshouldbecheckedevery2years.Checkandmaintenanceandrepairfortheunit,pleasecontactthelocaldistributorfordetails.4Itcantbeusedwhilethewrist(arm)hasbleedingorwoundtoavoidthebloodflowingfromthewoundinpressurizing.5Appliedpartscontainscuff.6ProtectionClass:Internallypoweredequipment.7MoistureProtection:IP21,continueoperation.8WARNING:Nomodificationofthisequipmentisallowed.9GuidanceandmanufacturersdeclarationelectromagneticemissionsGuidanceandmanufacturersdeclarationelectromagneticemissionsTheBLOODPRESSUREMONITORisintendedforuseintheelectromagneticenvironmentspecifiedbelow.ThecustomerortheuseroftheBLOODPRESSUREMONITORshouldassurethatitisusedinsuchanenvironment. MUMU-BPBloodPressureMonitorManualV0.5Page33EmissionsComplianceElectromagneticenvironment--guidanceRFemissionsCISPR11Group1TheBLOODPRESSUREMONITORusesRFenergyonlyforitsinternalfunction.Therefore,itsRFemissionsareverylowandarenotlikelytocauseanyinterferenceinnearbyelectronicequipment.RFemissionsCISPR11ClassBTheBLOODPRESSUREMONITORissuitableforuseinallestablishments,includingdomesticestablishmentsandthosedirectlyconnectedtothepubliclow-voltagepowersupplynetworkthatsuppliesbuildingsusedfordomesticpurposes.HarmonicemissionsIEC61000-3-2ClassAVoltagefluctuations/flickeremissionsIEC61000-3-3CompliesGuidanceandmanufacturersdeclarationelectromagneticimmunityGuidanceandmanufacturersdeclarationelectromagneticimmunityTheBLOODPRESSUREMONITORisintendedforuseintheelectromagneticenvironmentspecifiedbelow.ThecustomerortheuseroftheBLOODPRESSUREMONITORshouldassurethatitisusedinsuchanenvironment.ImmunitytestIEC60601testlevelCompliancelevelElectromagneticenvironment--guidanceElectrostaticdischarge(ESD)IEC61000-4-26kVcontact8kVair6kVcontact8kVairFloorsshouldbewood,concreteorceramictile.Iffloorsarecoveredwithsyntheticmaterial,therelativehumidityshouldbeatleast30%.Electricalfasttransient/burstIEC61000-4-42kVforpowersupplylinesandpatientcoupledlines2kVforpowersupplylinesandpatientcoupledlinesMainspowerqualityshouldbethatofatypicalcommercialorhospitalenvironment.Surge1kVline(s)1kVline(s)andMainspowerqualityshouldbe MUMU-BPBloodPressureMonitorManualV0.5Page34IEC61000-4-5andneutralneutralthatofatypicalcommercialorhospitalenvironment.Voltagedips,shortinterruptionsandvoltagevariationsonpowersupplyinputlinesIEC61000-4-11<5%UT(>95%dipinUT)for0,5cycle40%UT(60%dipinUT)for5cycles70%UT(30%dipinUT)for25cycles<5%UT(>95%dipinUT)for5s<5%UT(>95%dipinUT)for0,5cycle40%UT(60%dipinUT)for5cycles70%UT(30%dipinUT)for25cycles)<5%UT(>95%dipinUT)for5sMainspowerqualityshouldbethatofatypicalcommercialorhospitalenvironment.Ifadipsoraninterruptionofmainspoweroccurs,thecurrentoftheBLOODPRESSUREMONITORmaybedroppedofffromnormallevel,itmaybenecessarytouseuninterruptiblepowersupplyorabattery.Powerfrequency(50/60Hz)magneticfieldIEC61000-4-83A/m3A/mPowerfrequencymagneticfieldsshouldbeatlevelscharacteristicofatypicallocationinatypicalcommercialorhospitalenvironment.NOTEUTisthea.c.mainsvoltagepriortoapplicationofthetestlevelGuidanceandmanufacturersdeclarationelectromagneticimmunityGuidanceandmanufacturersdeclarationelectromagneticimmunityTheBLOODPRESSUREMONITORisintendedforuseintheelectromagneticenvironmentspecifiedbelow.ThecustomerortheuseroftheBLOODPRESSUREMONITORshouldassurethatitisusedinsuchanenvironment.ImmunitytestIEC60601testlevelCompliancelevelElectromagneticenvironmentguidanceConductedRFIEC61000-4-6RadiatedRFIEC61000-4-33Vrms150kHzto80MHz3V/m80MHzto2.5GHz3Vrms3V/mPortableandmobileRFcommunicationsequipmentshouldbeusednoclosertoanypartoftheBLOODPRESSUREMONITOR,includingcables,thantherecommendedseparationdistancecalculatedfromtheequationapplicabletothefrequencyofthetransmitter.Recommendedseparationdistance MUMU-BPBloodPressureMonitorManualV0.5Page35wherePisthemaximumoutputpowerratingofthetransmitterinwatts(W)accordingtothetransmittermanufactureranddistherecommendedseparationDistanceinmetres(m).FieldstrengthsfromfixedRFtransmitters,asdeterminedbyanelectromagneticsitesurvey,ashouldbelessthanthecompliancelevelineachfrequencyrange.bInterferencemayoccurinthevicinityofequipmentmarkedwiththefollowingsymbol:NOTE1At80MHzand800MHz,thehigherfrequencyrangeapplies.NOTE2Theseguidelinesmaynotapplyinallsituations.Electromagneticpropagationisaffectedbyabsorptionandreflectionfromstructures,objectsandpeople.a.Fieldstrengthsfromfixedtransmitters,suchasbasestationsforradio(cellular/cordless)telephonesandlandmobileradios,amateurradio,AMandFMradiobroadcastandTVbroadcastcannotbepredictedtheoreticallywithaccuracy.ToassesstheelectromagneticenvironmentduetofixedRFtransmitters,anelectromagneticsitesurveyshouldbeconsidered.IfthemeasuredfieldstrengthinthelocationinwhichtheBLOODPRESSUREMONITORisusedexceedstheapplicableRFcompliancelevelabove,theBLOODPRESSUREMONITORshouldbeobservedtoverifynormaloperation.Ifabnormalperformanceisobserved,additionalmeasuresmaybenecessary,suchasre-orientingorrelocatingtheBLOODPRESSUREMONITOR.b.Overthefrequencyrange150kHzto80MHz,fieldstrengthsshouldbelessthan3V/m.RecommendedseparationdistancesbetweenportableandmobileRFcommunicationsequipmentandtheBLOODPRESSUREMONITORRecommendedseparationdistancesbetweenportableandmobileRFcommunicationsequipmentandtheBLOODPRESSUREMONITORTheBLOODPRESSUREMONITORisintendedforuseinanelectromagneticenvironmentinwhichradiatedRFdisturbancesarecontrolled.ThecustomerortheuseroftheBLOODPRESSUREMONITORcanhelppreventelectromagneticinterferencebymaintainingaminimumdistancebetweenportableandmobileRFcommunicationsequipment(transmitters)andtheBLOODPRESSUREMONITORasrecommendedbelow,accordingtothemaximum MUMU-BPBloodPressureMonitorManualV0.5Page36outputpowerofthecommunicationsequipment.RatedmaximumoutputpoweroftransmitterWSeparationdistanceaccordingtofrequencyoftransmitterm150kHzto80MHz80MHzto800MHz800MHzto2.5GHz0.010.120.120.230.10.380.380.7311.21.22.3103.83.87.3100121223Fortransmittersratedatamaximumoutputpowernotlistedabove,therecommendedseparationdistancedinmetres(m)canbeestimatedusingtheequationapplicabletothefrequencyofthetransmitter,wherePisthemaximumoutputpowerratingofthetransmitterinwatts(W)accordingtothetransmittermanufacturer.NOTE1At80MHzand800MHz,theseparationdistanceforthehigherfrequencyrangeapplies.NOTE2Theseguidelinesmaynotapplyinallsituations.Electromagneticpropagationisaffectedbyabsorptionandreflectionfromstructures,objectsandpeople. MUMU-BPBloodPressureMonitorManualV0.5Page373.8SymbolSYMBOLSMEANSIndicatesapotentiallyhazardoussituationwhich,ifnotavoided,couldresultindeathorseriousinjury.Indicatesapotentiallyhazardoussituationwhich,ifnotavoided,mayresultinminorormoderateinjurytotheuserorpatientordamagetotheequipmentorotherproperty.TypeBFAppliedPartAUTHORISEDREPRESENTATIVEINTHEEUROPEANCOMMUNITYMANUFACTURERCEMarkThemarkingofelectricalandelectronicsdevicesaccordingtoDirective2002/96/EC.Thedevice,accessoriesandthepackaginghavetobedisposedofwastecorrectlyattheendoftheusage.PleasefollowLocalOrdinancesorRegulationsfordisposalRefertoUserManual.