Thermostat User Manual Many thanks for your selection of our products and services, and also for your trust and support to us. Electrical shock or equipment Damage Hazard. or short equipment circuitry. Disconnect power supply before installation Wiring Diagram Search for "Smart RM" Download the Wifi App with the following icon Turn on the thermostat, press and hold the key combination and Activate Electric heating wiring diagram WIFI distribution network icon The App advanced password is 123456
(6) Display size : 64*64mm
(7) Colorwhite,black Including built-in sensor and external sensor 0.5C accuracy keeps temperature within the level you set. Children lock to prevent misoperation by children Features Appearance
(1) Standard total Size is 86*86mm
(2) Touch buttons to make simple operation
(3) The visible thickness above the wall is only 15mm
(4) 86mm hidden box and 60mm European box
(5) Flat mounting,it is easy to install Functions
(A)
(B)
(C)
(D) Data memory when power is off.
(E) Holiday mode make you enjoy more comfortable temperature in holiday
(F) Product Specifications Power: 90-240Vac 50/60HZ Display accuracy:0.5C Probe sensor:NTC(10k)1%
Contact capacity:3A/250V(WW);16A/250V(WE) Output: Switch relay Working environment temperature:0~90C Range of temperature adjustment:5~35C Before wiring and installing 1. The temperature of external sensor can be checked Range of temperature display:0~40C Insulating condition: Normal environment Running program: Set per 1 week as a cycle Installation: Wall mounted or on battery seat Size(mm)86*86*27 Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. Check the ratings given in the instructions and on the product to make sure the produce is suitable for your application. Installer must be a trained experienced service technician. After installation is complete.check out produce operation as provided in these instructions CAUTION 2. 3. 4. Water heating wiring diagram
(do not connect terminal "close 4" of electric valve) Water heating and gas wall-hung boiler heating, no contact wiringdiagram,(disconnection when electric valve close) Note:3 & 4 connect with power, 5 & 6 connect with gas boiler,1& 2 connect with thermal actuator, please do not connect 1&2 to gas boiler,If you connect it wrongly, there will be Short circuit,our gas boiler board will be damaged. Displays Description of icon Auto mode;run preset program Temporary manual mode Holiday mode, Holiday days and temperature can be set to run in countdown mode Manual mode Clock Heating,,icon disappears to stop heating External NTC sensor WIFI connection, flashing EZ distribution mode Child lock Wifi status: Disconnection Cloud icon: flashing AP distribution network mode Operation key NO A symbols represent Turn ON/OFF:Short press to turn on/ turn off B C B D to switch automatic mode and manual mode for 3-5 seconds to enter into programmable for 3-5 seconds to enter into advanced setting 1 Short press 2 Turn on thermostat, long press setting 3. Turn off thermostat, long press 1 Confirm key: use it with key 2 Only short press it to set time 3 Turn on thermostat,long press it for 3-5seconds to holiday mode setting. Appear OFF, press 1 Decrease key 2 Long press to lock /unlock 1 Increase key :
2 Long press to inquire external sensor temperature to confirm opening holiday mode change to ON,then press or 3 In the Auto model, press or enter to temporary manual mode Programmable 5+2 (factory default),6+1 and 7 models 6 times period setting for user choose. In the advanced options for 3-5 seconds enter into programming choose model of you need, under power on state, long press mode setting, then short press to adjust data, finished setting, about 10 seconds will automatic save and exist. choose: hour,minute, time period, and press and Back home Sleep 15 2200 15 Out door Out door Back home 15 1330 20 800 15 1130 Wake up 600 The optimum comfort temperature is 18-22. Advanced options Under turn off state, long press From A1 to AD, short press to choose the option, and adjust data by next option.Remain about 5 seconds after finish setting will quit setting. Data Setting Function NO 15 1700 for 3-5 seconds to access advanced setting.
,
, short press to switch control Setting Options Measure Temperature Calibration Temperature return difference setting External temperature return difference Options of sensor control sensors limit control A1 A2 A3 A4
-9-+9 0.5-2.5 1-9 N1:Built-in sensor (high temperature protection close) Factory Default 0.5 Accuracy Calibration 1 2 NI limit temperature (external sensor detect N2:External sensor (high temperature protection close) N3:Built-in sensor control temperature ,external sensor the temperature is higher than highest temperature of external sensor, thermostat will disconnect relay,turn off load) 0:half lock 1. 35-70 2. Under 35, screen display--, high temperature protection was cancelled 1. 1-10 2. temperature protection was cancelled. Exceed 10, screen display--, Low 1:full lock 1-10 20-70 0:Close descaling function 1:Open descaling function valve is continuously closed over 100 hours it will be opened for 3 minutes automatically 0:Power with memory function 1:Shutdown power after power off 2:Shutdown power after power on 0: 5+2 1: 6+1 2: 7 Display A o, press key whole show 0 45 5 5 35 0:Close descaling function 0:Power with memory function 0: 5+2 A5 A6 A7 A8 A9 of of value value Children lock setting Limit high temperature for external sensor Limit low temperature for external sensor(anti-freeze protection) Setting lowest limit Setting highest Limit temperature temperature AA Descaling function Power with memory function Weekly selection programming AB AC Restore factory defaults AD Return difference : limit valve of external sensor is 45 for factory default (A6),value of external sensor control return difference (A3) is 2. when temperature rise to 45,then relay stop working and will remind high temperature production alarm. If temperature decline to 43relay continue to work and heating alarm will be relieved. (it can be operated ,only when indoor temperature is lower than setting temperature ) Sensor fault display:please choose correct working way of built-in and external sensor, if choose wrongly or sensor fault (breakdown), E1 or E2 will be displayed on the screen. Thermostat will stop heating until the fault is eliminated Warranty We offer the warranty of 18 months, from the sales day. The products of our company can have lifetime warranty ,if it is not the quality problems, or beyond the warranty period, we will charge for the after-sale service. FCC Warnning:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.