Warnings:
1. The intercom system including an outdoor station,an indoor station and a power supply. Please read this manual before installation, and then install it according to this instruction. 2. To avoid the danger of electric shock,please make sure that the power system is off before installation or maintenance. 3. If you are not a professional, please do not disassemble the shell to avoid electric shock. 4. Only the TF card is configured, will the video recording function be available. You can purchase TF cards and install it on the indoor station according to your own needs. Description of product model Sequence No. Model Product Name 1 2 3 4 EH2W-OS-M55-006 Model 15 Two Wires Digital Outdoor Station EH2W-OS-M55-007 Model 15 Two Wires Digital Outdoor Station EH2W-OS-M55-008 Model 15 Two Wires Digital Outdoor Station EH2W-OS-M55-009 Model 15 Two Wires Digital Outdoor Station Model 15 Two Wires Digital Outdoor Station User Manual FP.EH2W.OS.M55 Contents 1. Contents of the Package 1. Contents of the Package ............................................................................................................................................. 1 2. Product Description..................................................................................................................................................... 2.1 Product appearance(Four types)........................................................................................................................... 2 2 2.2 Main Technical Parameters ................................................................................................................................... 3 3 3. System Installation....................................................................................................................................................... 3 3.1 Wire Assignment and Distance.............................................................................................................................. 3 3.2 Connection Diagram............................................................................................................................................... 3 3.2.1 One to One Kit................................................................................................................................................ 4 3.2.2 Multi to Multi Kit.............................................................................................................................................. 5 3.2.3 Lock Connection Instructions ......................................................................................................................... 3.3 Installation.............................................................................................................................................................. 6 6 3.3.1 Surface Mounted Installation.......................................................................................................................... 6 3.3.2 Flush Mounted Installation ............................................................................................................................. 6 3.3.3 Replace Nameplate of Outdoor Station............................................................................................................ 7 4. Parameter Settings....................................................................................................................................................... 7 4.1 Enter Setting Function............................................................................................................................................. 7 4.2 Outdoor Station Parameter Settings........................................................................................................................ 7 4.2.1 Parameter Setting List.................................................................................................................................... 7 4.2.2 Outdoor Station Name.................................................................................................................................... 7 4.2.3 Removing Alarm Setting................................................................................................................................. 7 4.2.4 Ring-back Tone Setting................................................................................................................................... 7 4.2.5 Card Management.......................................................................................................................................... 8 4.2.6 Unlocking Setting............................................................................................................................................ 8 4.2.7 IP Setting........................................................................................................................................................ 8 5. Description of the System Functions............................................................................................................................... 5.1 Call,Intercom and Leave Message................................................................................................................................ 8 5.2 Monitor................................................................................................................................................................... 8 Outdoor Station Different Identical 2 Nameplate 1 2 1 Rain shield Screws Screws M55-001 3 1 1 Expansion tube Screw driver Wire(2.0) Card reader 3 1 M55-002 Wire(2.54) Wire(2.54) M55-003 2 Nameplate 1 2 1 Embedded box Copper nut Screws 1 1 3 Screw driver Wire(2.0) Wire(2.54) 5.3 Unlock by Card ...................................................................................................................................................... 9 Card reader 9 5.4 Unlock by Exit Button.............................................................................................................................................. FCC ................................................................................................................................................................................ 10 Toxic and hazardous substances or elements ................................................................................................................ 11 M55-004 1 Wire(2.54) 1 2. Product Description 2.1 Product appearance(Four types) EH2W-OS-M55-001 EH2W-OS-M55-002 1 2 3 4 5 6 7 8 9 10 11 12 1. Camera 2. Loudspeaker 3. Nameplate 4. Call Button 5. Microphone 6. Card Reader 7. 2-wire Communication Port 8. Exit Port 9. Lock2 Port 10. Lock1 Port 11. Door Status Detector Port 12. Anti-dismantle Alarm Trigger EH2W-OS-M55-003 EH2W-OS-M55-004 1 2 3 4 5 6 7 8 9 10 11 12 1. Camera 2. Loudspeaker 3. Nameplate 4. Call Button 5. Microphone 6. Card Reader 7. 2-wire Communication Port 8. Exit Port 9. Lock2 Port 10. Lock1 Port 11. Door Status Detector Port 12. Anti-dismantle Alarm Trigger 2.2 Main Technical Parameters Outdoor Station 1/4 CMOS 1080p 24V Camera Video format Working voltage Operation mode Mechanical key Max power consumption 5W Standby power consumption 1W Ingress protection IP54 CardType IC card Card capacity Working temperature -40~ 55 External dimensions(mm) 7914645(M55-001/M55-002) 9316832(M55-003/M55-004) 100
(WHD) 3. System Installation 3.1 Wire Assignment and Distance Wire Assignment Length(m) AWG21 AWG22 AWG23 AWG24 3.2 Connection Diagram 3.2.1 One to One Kit A. System Expansion Diagram W i F i 80 80 80 80 2-wire 2-wire Power or Power Supply Adaptor IPCamera Exit Button Lock 1 Lock 2 Door Open Detector 1 Door Open Detector 2 2 3 B. Standard Installation B. Standard Installation Exit Button Switch-
Switch+
NO COM NC Switch Output
(Lock2) Power Control Output(Lock1) Exit Port Gnd Bus-
Bus+
Door1 Open Gnd Door2 Open OutDoor Station Door2 Open Detector Door1 Open Detector 110/220V AC~
d n NLG
-
r e w o P
+
r e w o P N L
- -+ +
Power or Power Supply Adaptor P o w e r
-
P o w e r
+
EH2W-MD-D04-001 2-Wires Digital Distributor LAN : 10/100M Bus : 10M Power: 24VDC Power 1 2 3 4 5 6 7 8 2-Wire Digital Distributor B u s
-
B u s
+
B u s
-
B u s
+
B u s
-
B u s
+
B u s
-
B u s
+
B u s
-
B u s
+
B u s
-
B u s
+
B u s
-
B u s
+
B u s
-
B u s
+
Connect to other Indoor/Outdoor Station InDoor Station
-
s u B
+
s u B DoorBell DoorBell DoorBell Power+
Power-
110/220V AC~
d n N LG
-
r e w o P
+
r e w o P N L
- -+ +
Power or Power Supply Adaptor 3.2.2 Multi to multi Kit A. System Expansion Diagram Power or Power Supply Adaptor EH2W-MD-D04-001 2-Wires Digital Distributor LAN : 10/100M Bus : 10M Power: 24VDC Power 1 2 3 4 5 6 7 8 2-wire 2-wire 2-wire 2-wire W i F i W iFi IPCamera DoorBell DoorBell DoorBell
-
s u B
+
s u B Power+
Power-
InDoor Station 3.2.3 Lock Connection Instructions Power Control Output (Lock1) Unlock NO COM NC
+12V Gnd Switch Output(Lock2) Unlock Switch -
Switch +
OutDoor Station Exit Button Exit Port Gnd Bus-
Bus+
Door1 Open Gnd Door2 Open Door2 Open Detector Door1 Open Detector Switch-
Switch+
Switch Output
(Lock2) NO COM NC Power Control Output(Lock1) Note If the lock is opened by stopping power supply, the lock should be connected to NC and COM terminals, and the normal working current of the lock is no more than 800mA. If the lock is opened by power supply to the lock, the lock shall be connected to the NO and COM terminals, and the current is no more than 800mA when the lock is opened. Note Lock 2 is the signal output mode, which is normally disconnected and connected when the lock is opened. The maximum voltage supported by lock 2 is 24VDC and the maximum current is less than or equal to 800mA. 4 5 3.3 Installation 3.3.1 Surface Mounted Installation Wall Rain Shield M3 Self-tapping Door Panel Screw 3.3.2 Flush Mounted Installation Wall Embedded Box Door Panel Screw 3.3.3 Replace Nameplate of Outdoor Station 1. Drill the hole at the appropriate height on the wall, and then insert the rubber plug into the hole on the wall. 2. Fix the rain shield on the wall with the screw. 3. Connect the wire to the outdoor station. 4. Fix the outdoor station to the rain shield with the screw. 4. Parameter Settings 4.1 Enter Setting Function Set outdoor station parameters Home 1 1 Set system parameters 08:22am 2018/08/08 Monday Record Monitor Privacy Screen Lock Intercom Settings Set indoor station parameters 2. The indoor station shows the setting list page. 1. Touch the Icon. System Parameters Outdoor Station1Outdoor Station2 Indoor Station1 Indoor Station2 Note: If the outdoor stations or the indoor stations is not connected, the outdoor station settings icon and the indoor station settings icon will be missing. 4.2 Outdoor Station Parameter Settings 4.2.1 Parameter Setting List 4.2.2 Outdoor Station Name 1. Trepan a hole in the appropriate position on the wall, insert the embedded box in the wall slightly, and fix it with the cement slurry. 2. Connect the wire to the outdoor station. 3. Fix the outdoor station of which a sponge pad is pasted at the alarm trigger, and lock the outdoor station with the screw. Outdoor Station Settings Removal Alarm Name Ring-back tone Unlocking Cards About IP Address Outdoor Station Settings Removal Alarm Name Ring-back tone Input OS Name Outdoor Station1 Unlocking Cards About IP Address 4.2.3 Removing Alarm Setting 4.2.4 Ring-back Tone Setting Outdoor Station Settings Removal Alarm Name Ring-back tone Removal alarm Unlocking Cards About IP Address 4.2.5 Card Management 1/1 No. 1 2 Card No. 01022238 02013366 Time 2018-07-10 10:02:22 2018-07-10 10:02:22 Sounds Volume 0%
25% 50% 75% 100%
1. Press the Registering Card button to start. 2. The indoor station shows registration cards page. 3. User can swip all cards on the outdoor station. 1/1 No. 1 2 3 Card No. 1111-0001 1111-0002 1111-0003 Time 2018-07-10 10:02:22 2018-07-10 10:02:22 2018-07-10 10:02:22 Registering Cards:01 Finish 1.Push down and push to the left. 2.Take out the nameplate. 3.Change the nameplate sticker. 4.Push down and push to the right. 6 7 4. The indoor station shows how many cards have been registered. 5. User can press the call button to finish registration. 6. User also can press the finish button to finish registration. 4.2.6 Unlocking Setting 4.2.7 IP Setting 5.3 Unlock by Card 5.4 Unlock by Exit Button Unlocking 5 20 Lock1 Delay Time(s) Lock2 Delay Time(s) Lock1 door sensor Door open delay alarm Lock2 door sensor Door open delay alarm Manual Setting IP Address Subnet Mask Router DNS Note:
The router address of the outdoor station should be filled in with the IP address of the main indoor station. User can open the outdoor stations Lock1 by the registered card. For the card registration, see the description(4.2.5) in the parameter settings section. Exit Button User can open the outdoor stations Lock1 by press the Exit Button. 5. Description of the System Functions 5.1 Call,Intercom and Leave Message 2. The indoor station shows the ring page. 1. The visitor pushes the call button. Answer Hang up Open the door 1 Open the door 2 Switch the IPC video More Note:
If the equipment with a TF card, video will be recorded automatically when the bell rings. Otherwise, take a photo snap. In intercom, you can press or to open the corresponding door. In intercom,you can press to switch the monitor video,then you can view other monitoring video. In intercom, press the to expand other function buttons. For leave message,the visitor can press the call button to leave a message after hearing message notice and press the call button to end talking after leaving a message. 5.2 Monitor 08:22am 2018/08/08 Monday 1 1 1. User press the Monitor icon. Monitor List 2. The indoor station shows the monitor list. Outdoor Station1 Outdoor Station2 IPC1 Record Monitor Privacy Screen Lock Intercom Settings IPC2 IPC3 IPC4 3. User press the Outdoor Station icon or IPC icon to monitor the video. 4. The indoor station shows the monitor page. Note:
In the monitoring state, press the to initiate a call to the outdoor station,so that you can talk to someone outside the door. Return Call Open the door 1 Open the door 2 Switch the IPC video More 8 9 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The statements should be displayed in the user manual:
changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help. 10 Part Name Metal Part Plastic Part CRT display screen LCD screen Circuit board component*
Power/
cord/cable Power/
adapter Packaging Toxic and hazardous substances or elements Lead
(Pb) Mercury
(Hg) Cadmium
(Cd) Hexavale nt nobeliu m(Cr6 +) Polybromi nated biph enyl
(PBB) Polybromi nated diph enylether
(PBDE) O O X O X X X O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O
*: Circuit board components include a printed circuit board and its components, such as resistors, capacitors, integrated circuits, etc.;
O: It indicates that the contents of the hazardous substanse in all homogeneous materials of the part are below the limit requirement specified in IEC62321;
X: It indicates that the contents of the hazardous substanse in at least one of the homogeneous materials of the part exceed the limit requirement specified in IEC62321;
Technical specifications and contents are subject to change without notice. RoHS 11