all | frequencies |
|
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|---|
manuals | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual CS300 | Users Manual | 2.66 MiB | January 19 2024 | |||
1 |
|
User Manual HS100 | Users Manual | 2.76 MiB | January 19 2024 | |||
1 |
|
Internal photo | Internal Photos | 2.03 MiB | January 19 2024 | |||
1 |
|
External Photos | External Photos | 781.70 KiB | January 19 2024 | |||
1 |
|
Label and location | ID Label/Location Info | 394.26 KiB | January 19 2024 | |||
1 |
|
ACB-FORM-FCC-Application-Letters-Agency-Letter | Cover Letter(s) | 224.81 KiB | January 19 2024 | |||
1 |
|
ACB-FORM-FCC-Application-Letters-Confidentiality-Letter | Cover Letter(s) | 266.10 KiB | January 19 2024 | |||
1 |
|
ACB-FORM-FCC-Application-Letters-Covered-List-Attestation | Attestation Statements | 273.84 KiB | January 19 2024 | |||
1 |
|
ACB-FORM-FCC-Application-Letters-U.S.-Agent-Letter-for-Service-of-Process | Attestation Statements | 257.72 KiB | January 19 2024 | |||
1 |
|
Antenna Declaration Letter | Test Report | 33.88 KiB | January 19 2024 | |||
1 | Confidential Block Diagram 4G, WIFI, RFID rev1 | Block Diagram | January 19 2024 | confidential | ||||
1 | Confidential Block Diagram LTE | Block Diagram | January 19 2024 | confidential | ||||
1 | Confidential Block Diagram WIFI, RFID | Block Diagram | January 19 2024 | confidential | ||||
1 | Confidential Operation Description | Operational Description | January 19 2024 | confidential | ||||
1 | Confidential Schematics | Schematics | January 19 2024 | confidential | ||||
1 | Confidential Schematics LTE | Schematics | January 19 2024 | confidential | ||||
1 | Confidential Schematics WIFI | Schematics | January 19 2024 | confidential | ||||
1 |
|
Declaration rev1 | Cover Letter(s) | 270.88 KiB | January 19 2024 | |||
1 |
|
FCC Report 15.225 rev1 | Test Report | 747.60 KiB | January 19 2024 | |||
1 |
|
Report FCC MPE rev1 | RF Exposure Info | 359.34 KiB | January 19 2024 | |||
1 |
|
Test Setup | Test Setup Photos | 452.96 KiB | January 19 2024 |
1 | User Manual CS300 | Users Manual | 2.66 MiB | January 19 2024 |
Electric Vehicle AC Charger Installation Manual For model: CS300 CONTENTS 1.Safety Instructions .................................................................... 1 1.1.Warnings & Cautions ............................................................................ 1 1.2.Installation Requirements .................................................................... 2 1.3.Daily Maintenance ............................................................................... 2 1.Consignes De Scurit Importantes ............................................ 4 1.1.Avertissement & Mise En Garde Gnraux ........................................... 4 1.2.Exigence Avant Linstallation ............................................................... 5 1.3.Daily Maintenance ............................................................................... 5 2.Product Introduction ................................................................. 7 2.1.Basic Interface .................................................................................... 7 2.2.Basic Dimension ................................................................................. 8 2.3.Specif ications ...................................................................................... 9 2.4.Design Standards ............................................................................... 10 3.Accessories .............................................................................11 4.Tools for Mounting ...................................................................12 5.Plan for Mounting.....................................................................13 6.Operate Your Device .................................................................17 6.1.Operating Steps with Plug and Charge ............................................... 17 6.2.Operating Steps with RFID Card ......................................................... 19 7.Light Codes .............................................................................21 7.1.After Start UP ..................................................................................... 21 7.2.Error and Warning Messages ............................................................. 21 8.FCC STATEMENT ......................................................................22 9.Warranty and Maintenance .......................................................23 1. Safety Instructions 1.1.Warnings & Cautions WARNING To avoid fire, injury or death, read and follow the instructions carefully during installation, operation and maintenance. DO NOT put fingers into the electric vehicle connector. DO NOT use this product if the power cord or EV cable is frayed, insulation-
broken, or any other signs of damage. DO NOT use this product if the enclosure or the EV connector is broken, cracked, open, or shows any other indication of damage. DO NOT remove cover or attempt to open the enclosure because of risk of electric shock. This device should be supervised when used around children. This device must be grounded. To avoid the risk of fire or electric shock, do not use this device with an extension cord. The suitability of the use of flexible cord in accordance with CE code, part I, rule 4-012, is to be determined by the local inspection authority. To reduce the risk of fire, connect only to a circuit provided branch circuit over-
current protection in accordance with the CSA C22. 1 15 Canadian Electrical Code, Part 1 (Canada) or NOM-001-SEDE Electrical installations (utility) (Mexico) or ANSI / NFPA 70 National Electrical Code (USA). Circuit Breaker Options Output Amperage (A) Circuit Breaker Options (A) 16A 20A 32A 40A 40A 50A 48A 60A 80A 100A 1 CS300WARNING WARNING CS300 1.2.Installation Requirements WARNING Disconnect electrical power prior to installing the charging station. Be sure to preview the user manual and ensure local building and electrical codes are reviewed before installing the AC charger. The AC charger should be installed by a qualified technician according to the user manual and local safety regulations. CAUTION Use appropriate protection when connecting to the main power distribution cable. Type B, C or D breaker with the rating current for table should be installed in the upstream AC distribution box. Disconnect switch for each ungrounded conductor of AC input shall be provided by others in accordance with the National Electric Code, ANSI/
NFPA70. The device shall be mounted at the height between 600 mm and 1200 mm from ground. Please keep the charger in a clean area with low humidity. Not recommended to be installed in coastal environments with high humidity or thick dust. 1.3.Daily Maintenance CAUTION Avoid moisture or water in the charger. If there is water or moisture ingress in the charger, it is necessary to immediately power off to avoid immediate danger and notify the professionals to carry out maintenance before next use. Please use the charger properly. Do not hit or press hard on the enclosure. If it 2 CS300 WARNING is damaged, please contact a professional technician. Avoid placing the charger near hot objects and at high temperature locations and away from dangerous substances such as flammable gases and corrosive materials. To avoid any danger, please do not put any heavy objects on the charger. 3 1. Consignes De Scurit Importantes 1.1.Avertissement & Mise En Garde Gnraux AVERTISSEMENT Pour viter les risques dincendie, de blessure ou de mort, il faut lire et suivre soigneusement les instructions pendant linstallation, lutilisation et lentretien. Ne mettez pas les doigts dans le connecteur du vhicule lectrique. N'utilisez pas ce produit si le cordon d'alimentation flexible ou le cble EV est effiloch, isolou prsentant tout autre signe de dommage. N'utilisez pas ce produit si le botier ou le connecteur EV est cass, fissur, ouvert ou montre toute autre indication de dommage. Ne retirez pas le couvercle et n'essayez pas d'ouvrir le botier en raison du risque de choc lectrique. Cet appareil doit tre surveill lorsqu'il est utilis proximit d'enfants. Cet appareil doit tre mis la terre. Pour viter tout risque d'incendie ou de choc lectrique, n'utilisez pas cet appareil avec une rallonge lectrique. L'adquation de l'utilisation du cordon flexible conformment au code ce, partie i, rgle 4-012, doit tre dtermine par l'autoritd'inspection locale comptente. Pour rduire les risques d'incendie, ne connecter qu' un circuit protection contre les surintensits des circuits de drivation conformment la norme canadienne CSA C22. 1-15 Code lectrique, partie 1 (Canada) ou NOM-
001-SEDE Installations lectriques (Mexique) ou ANSI / NFPA 70 National Electrical Code (tats-Unis). Tableau Des Options Du Disjoncteur Courant De Sortie (A) Options De Disjoncteur (A) 16A 20A 32A 40A 40A 50A 48A 60A 80A 100A 4 CS300AVERTISSEMENT CS300 AVERTISSEMENT 1.2.Exigence Avant Linstallation AVERTISSEMENT Assurez-vous de consulter le manuel d'utilisation et assurez-vous que les codes locaux du btiment et de l'lectricit sont passs en revue avant d'installer le chargeur. Dbranchez l'alimentation lectrique avant d'installer la station de charge. Le chargeur CA doit tre install par un technicien qualifi conformment au manuel d'utilisation et aux rglementations de scurit locales. MISE EN GARDE Utilisez une protection approprie lors de la connexion au cble de distribution d'alimentation principal. Un disjoncteur de B, C ou D avec le courant nominal indiqu dans le tableau doit tre install dans le botier de distribution CA en amont. L'interrupteur de dconnexion pour chaque conducteur non mis la terre de l'entre CA doit tre fourni par des tiers conformment au Code national de l'lectricit, ANSI/NFPA70. Cet appareil doit tre mont une hauteur entre 600 mm (2 pieds) et 1200 mm (4 pieds) du sol. Veuillez conserver le chargeur dans un endroit propre et peu humide. Il nest pas recommand de l'installer dans des environnements ctiers forte humidit ou forte poussire. 1.3.Daily Maintenance MISE EN GARDE vitez l'humidit ou l'eau dans le chargeur. En cas d'infiltration d'eau ou d'humidit dans le chargeur, il est ncessaire de l'teindre immdiatement pour viter tout 5 AVERTISSEMENT CS300 danger immdiat et d'avertir le personnel professionnel d'effectuer l'entretien avant la prochaine utilisation. Veuillez utiliser le chargeur correctement. Ne frappez pas ou n'appuyez pas trop fort sur le botier. Si le botier est endommag, veuillez contacter un technicien professionnel. vitez de placer le chargeur proximit d'objets chauds et des endroits haute temprature et loin de substances dangereuses telles que des gaz inflammables et des matriaux corrosifs. Pour viter tout danger, veuillez ne pas mettre d'objets lourds sur le chargeur. 6 CS300 INTRODUCTION 2. Product Introduction CAUTION: Avoid placing the charger near hot objects or high temperature locations and away from dangerous substances such as flammable gases and corrosive materials. 2.1.Basic Interface LED Light Indication LCD Screen Rear Notch Charging cable SAE J1772 AC Charging Connector Input Power Cable 7 2.2.Basic Dimension ENCLOSURE 245 mm 9.65 365 mm 14.37 87.4 mm 3.44 365 mm 14.37 102 mm 4.02 121.47 mm 4.78 Front View Left View 245 mm 9.65 Bottom View WALL-MOUNTED HOLES 40 mm 1.57 60 mm 2.36 120 mm 4.72 40 mm 1.57 35 mm 1.38 8 CS300INTRODUCTION 2.3.Specif ications Model Name CS300-32A CS300-40A CS300-48A CS300-80A Power Specif ication Input AC Rating Max. AC Current Frequency 208-240Vac 32A 40A 48A 80A 60Hz Max. Output Power 7.6kW 9.6kW 11.5kW 19.2kW User Interface &
Control Display LED Indicator Push Buttons 5(7 optional) LCD Screen Yes Restart Button User Authentication RFID(ISO/IEC 14443 A/B), APP Network Interface LAN(Standard), Wi-Fi/Bluetooth/3G/4G Optional Communication Communication Protocol OCPP1.6 J/OCPP2.0.1 Upgradeable Environment Communication Function ISO/IEC 15118 Optional Operating Temperature
-22 to 122 Humidity Altitude IP/IK Level 5%~95% RH, Non-condensing 6562ft(2000m), No Derating NEMA Type3R(IP65)/IK10 Cabinet Dimension (WDH) 9.6514.374.78(245mm365mm121.47mm) Mechanical Weight 16.98lbs(7.7kgs) Cable Length 18ft(5.5m)(Standard)/25ft(7.5m)(Optional) Protection Multiple Protection OVP(Over Voltage Protection), OCP(Over Current Protection), OTP(Over Temperature Protection), UVP(Under Voltage Protection), SPD(Surge Protection Detection), Grounding Protection, SCP(Short Circuit Protection), Control Pilot Fault, Relay Welding Detection, CCID Self-test Regulation Safety Certif icate Charging Interface UL 2594, UL2231-1/-2 ETL, FCC SAE J1772 Type 1 9 CS300INTRODUCTION 2.4.Design Standards UL 2594: Electric Vehicle Supply Equipment. UL 2231-1: UL Prersonnel Protection System s for Electric Vehicle (EV) Supply Circuits:General Requirements. UL 2231: Personnel Protection Systems for Electric Vehicle (EV) Supply Circuits: Particular Requirements for Protection Devices for Use in Charging Systems. UL 2251: Plugs, Receptacles and Couplers for Electric Vehicles. UL 62: Flexible Cords and Cables. UL 991: Tests for Safety-Related Controls Employing Solid-State Devices. UL 1998: Software in Programmable Components. NFPA 70 Article 625: National Electrical Code, Electric Vehicle Charging System UL 840
(Clearance and Creepage). 10 CS300INTRODUCTION 3. Accessories Check the box to ensure you have this installation guide and these parts:
Electric Vehicle AC Charger Installation Manual For model: CS300 1 AC Charger 2 User Manual 3 M48 Screws*2 4 M3X8 Screws*2 5 M6 Hexagonal Expansion Screws*2 6 Standard RFID Cards*2 7 Mounting Bracket No. Product Name Quantity Description 1 2 3 4 AC Charger User Manual M48 Screws M3X8 Screws 5 M6 Hexagonal Expansion Screws 6 Standard RFID Cards 7 Mounting Bracket 1 1 2 2 2 2 1 With attached input power cable and output charging cable. PDF version available online. For installing the AC Charger to the Bracket. For fastening front cover on AC Charger For installing the Mounting Bracket to the wall / structure. To start/stop charger for the unit with RFID reader. For easy drilling of 2 screws holes for AC Charger. 11 CS300ACCESSORIES 4. Tools for Mounting Tools required before installing the Wall-mounted charger, gather the following tools:
T10 T20 1 Wire stripper 2 Phillips and T10, T20 screwdriver 3 Drill 4 Level 5 Pencil or marker 6 Adjustable wrench NOTE: The above tools are very important, get them ready prior to installation. 7 Voltmeter or digital multi-
meter (for measuring AC voltage at the installation site) 12 CS300MOUNTING CS300 MOUNTING 5. Plan for Mounting WARNING: In areas with frequent thunderstorms, add surge protection at the service panel for all circuits. Ensure all power and ground connections, especially those at the breaker and bus bar, are clean and tight. CAUTION: Not recommended to be installed in coastal environments with high humidity or thick dust. STEP 1 Select the appropriate mounting location with electrical capacity. i. Ensure the owner has chosen a mounting location that allows the charging cable to reach the cars charging port while still providing slack. II. The device must be anchored on a solid wall or a stud with the dimensions: 2 x 4. III. The device shall be mounted at height between 2 feet (600mm) and 4 feet (1200mm). STEP 2 Use a level to verify if a bracket is horizontally aligned and mark the holes by one pencil. 13 STEP 3 Drill 2 Screw Holes with a diameter of 0.33 and a depth of 2.05 by using #7 mounting bracket. STEP 4 Nail #5 two expansion rubber sleeves into the holes and nail #5 two M6 hexagonal expansion screws to secure the wall-mounted bracket on the wall. Then level the brackets. Insert the expansion nut 14 CS300MOUNTING CS300 STEP 5 Align the rear notch of charger with the wall-mounted bracket and fit the screw holes of the right and left side with #3 M48 Screws. MOUNTING T20 STEP 6 Wire the Circuit WARNING This device must be grounded. Disconnect electrical power prior to installing the charging station. Improper connection of the equipment-grounding conductor would result in a risk of electric shock. Check with a qualified electrician or service man if you are not sure whether the product is properly grounded. Do not modify the plug provided with the product if it doesnt fit the outlet, have a proper outlet installed by a qualified electrician. CAUTION Use appropriate protection when connecting to the main power distribution cable. For the safety purpose, please set circuit breaker protection in the input part of EV Charger. Please follow the instructions below:
Circuit Breaker Options Output Amperage (A) Circuit Breaker Options (A) 16A 20A 32A 40A 40A 50A 48A 60A 80A 100A 15 MOUNTING STEP 7 CS300 Please unclick the shelf with slotted screwdriver, connect L1 with grid L1, L2 with grid L2 and lead the PE to the grid PE. Click back the shelf, and fix the front cover back and tighten with #8 M3X8 Screws 2 screws at the buttom. PE L1 L2 PE L1 L2 D27 J27 CP CP L2 L1 PE PE L1 L2 T10 STEP 8 Overall outlook after installation 16 CS300 OPERATE 6. Operate Your Device WARNING This device should be supervised when used around children. CAUTION Please use the charger properly. Do not hit or press hard on the enclosure. If the case is damaged, please contact a professional technician. To avoid any danger, please do not put any heavy objects on the charger. 6.1.Operating Steps with Plug and Charge STEP 1 Standby Mode: After being powered on, the lights will be all on, blue light (STANDBY), green light (CHARGING) and red light (FAULT). Then the blue light (STANDBY) is constantly on in standby mode. Standby BLUE STEP 2 Plug the Charging Connector: Please plug the charging connector into the vehicle charging inlet
*Figures are for reference only 17 OPERATE STEP 3 CHARGING: The green light(CHARGING) turns, to flash automatically, charging is in process. You can see "Duration, Energy, Price, Amount, SN" in the LCD Screen. CS300 Charging GREEN
*Figures are for reference only GREEN RED Charging Fault
*Figures are for reference only STEP 4 The green light (CHARGE) turns to flash automatically, charging is in process. If the red light (FAULT) is on, plug the vehicle connector again. If red light is still on, please refer to "7.2. Error and Warning Messages". STEP 5 Charging finished: The charging process will be stopped once swipe RFID, the number of total kWh will be shown, this indicates the total kWh your car has received. Then please pull out the charging connector to stop the charging process.
*Figures are for reference only 18 CS300 OPERATE 6.2.Operating Steps with RFID Card STEP 1 Standby Mode: After being powered on, the lights will be all on, blue light (STANDBY), green light (CHARGING) and red light (FAULT). Then the blue light (STANDBY) is constantly on in standby mode. Standby BLUE
*Figures are for reference only
*Figures are for reference only STEP 2 Plug the Charging Connector: Please plug the charging connector into the vehicle charging inlet. STEP 3 Tap the standard RFID to start/stop charging.
*Figures are for reference only 19 OPERATE STEP 4 Charging: When the charging is going on, you will see the following information on the LCD screen "Duration, Energy, Price, Amount, SN". CS300 Charging GREEN
*Figures are for reference only GREEN RED Charging Fault
*Figures are for reference only STEP 5 The green light (CHARGE) turns to flash automatically, charging is in process. If the red light (FAULT) is on, plug the vehicle connector again. If red light is still on, please refer to "7.2. Error and Warning Messages". STEP 6 Charging finished: The charging process will be stopped once swipe RFID, the number of total kWh will be shown, this indicates the total kWh your car has received. Then please pull out the charging connector to stop the charging process.
*Figures are for reference only 20 7. Light Codes 7.1.After Start UP Standby Waiting to plug in Solid Blue Waiting to Charge, Communicating with Vehicle Solid Green Charging in Progress Finished Charging Fault Green Blinking Solid Green Solid Red 7.2.Error and Warning Message Status Off Ground RCD Abnormal Over Current Protection Over Voltage Protection Under Voltage Protection Energy Meter Fault Control Pilot Fault Over Temperature Protection Ground Fault Ground Self-Test Remark Auto Recover Auto Recover Auto Recover Auto Recover Auto Recover Contact Customer Service Auto Recover Auto Recover Auto Recover Auto Recover Screen Display 0001 0002 0004 0008 0016 0032 0128 0256 0512 1024 21 CS300WARNING WARNING CS300 8. FCC STATEMENT This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: This device may not cause harmful interference, and this device must accept any interference received, including interference that may cause undesired operation. Caution: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. WIFI module : Contains FCC ID:2AC7Z-ESP32WROOM32U LTE module : Contains FCC ID:XMR201909EC25AFX To satisfy FCC RF exposure requirements, a separation distance of 20cm or more should be maintained between the antenna of this device and persons during device operation. To ensure compliance, operations at closer than this distance is not recommended. 22 9. Warranty and Maintenance The warranty period for this charger is three years. During the warranty period for any malfunction under normal use according to the User Manual and Service Instructions (to be determined by certified maintenance technicians of sellers), the product shall be repaired free of charge. Except for the following situations, the charger shall be subject to the above warranty terms:
1. The warranty certificate cannot be provided or the contents of the warranty certificate are modified or inconsistent with the label indication of the repaired product. 2. Those who are unable to provide valid proof of purchase. 3. Those who exceed the manufacturer's specified warranty period. 4. Those who damage the product due to not following the product service instruction for use, maintenance and storage. 5. Damage or malfunction caused by external object entering. 6. Unauthorized repair, disassembly or modification. 7. Damage caused by force majeure (such as lightning, excessive voltage, earthquake, fire, flood, etc.). 8. Malfunction and damage caused by other unavoidable external factors. Malfunction and damage caused by improper use of equipment, such as water or other solutions entering into the equipment. 9. Malfunction and damage caused by the grid power supply and voltage which is not specified for use with the charger equipment. The above guarantees shall be made solely, and no other express or implied warranties shall be made (including the implied warranties of merchant ability, particular and applicable reason-ableness and adaptability, etc.) whether in the contract, civil negligence, or other aspects, the Company shall not be responsible for any special, incidental or consequential damages. 23 CS300WARNING
1 | User Manual HS100 | Users Manual | 2.76 MiB | January 19 2024 |
Electric Vehicle AC Charger Installation Manual For model: HS100 CONTENTS 1.Safety Instructions .................................................................... 1 1.1.Warnings & Cautions ............................................................................ 1 1.2.Installation Requirements .................................................................... 2 1.3.Daily Maintenance ............................................................................... 2 2.Product Introduction ................................................................. 4 2.1.Basic Interface .................................................................................... 4 2.2.Basic Dimension ................................................................................. 5 2.3.Specif ications ...................................................................................... 6 2.4.Design Standards ................................................................................. 7 3.Accessories .............................................................................. 8 4.Tools for Mounting .................................................................... 9 5.Plan for Mounting.....................................................................10 6.Operate Your Device .................................................................14 6.1.Operating Steps with Plug and Charge ............................................... 14 6.2.Operating Steps with RFID Card ......................................................... 16 7.Light Codes .............................................................................18 7.1.The Details of Screen ......................................................................... 18 7.2.Error and Warning Messages ............................................................. 18 8.FCC STATEMENT ......................................................................19 9.Warranty and Maintenance .......................................................20 1. Safety Instructions 1.1.Warnings & Cautions WARNING To avoid fire, injury or death, read and follow the instructions carefully during installation, operation and maintenance. DO NOT put fingers into the electric vehicle connector. DO NOT use this product if the power cord or EV cable is frayed, insulation-
broken, or any other signs of damage. DO NOT use this product if the enclosure or the EV connector is broken, cracked, open, or shows any other indication of damage. DO NOT remove cover or attempt to open the enclosure because of risk of electric shock. This device should be supervised when used around children. This device must be grounded. To avoid the risk of fire or electric shock, do not use this device with an extension cord. The suitability of the use of flexible cord in accordance with CE code, part I, rule 4-012, is to be determined by the local inspection authority. To reduce the risk of fire, connect only to a circuit provided branch circuit over-
current protection in accordance with the CSA C22. 1 15 Canadian Electrical Code, Part 1 (Canada) or NOM-001-SEDE Electrical installations (utility) (Mexico) or ANSI / NFPA 70 National Electrical Code (USA). Circuit Breaker Options Output Amperage (A) Circuit Breaker Options (A) 16A 20A 1 32A 40A 40A 50A 48A 60A WARNING HS100 1.2.Installation Requirements WARNING Disconnect electrical power prior to installing the charging station. Be sure to preview the user manual and ensure local building and electrical codes are reviewed before installing the AC charger. The AC charger should be installed by a qualified technician according to the user manual and local safety regulations. CAUTION Use appropriate protection when connecting to the main power distribution cable. Type B, C or D breaker with the rating current for table should be installed in the upstream AC distribution box. Disconnect switch for each ungrounded conductor of AC input shall be provided by others in accordance with the National Electric Code, ANSI/
NFPA70. The device shall be mounted at the height between 600 mm and 1200 mm from ground. Please keep the charger in a clean area with low humidity. Not recommended to be installed in coastal environments with high humidity or thick dust. 1.3.Daily Maintenance CAUTION Avoid moisture or water in the charger. If there is water or moisture ingress in the charger, it is necessary to immediately power off to avoid immediate danger and notify the professionals to carry out maintenance before next use. Please use the charger properly. Do not hit or press hard on the enclosure. If it 2 HS100 WARNING is damaged, please contact a professional technician. Avoid placing the charger near hot objects and at high temperature locations and away from dangerous substances such as flammable gases and corrosive materials. To avoid any danger, please do not put any heavy objects on the charger. For 48 Amp installations, we recommend not using a NEMA cable. Instead, we advise a professional electrician hardwire it to the wall, given the high power requirement which could potentially cause electrical issues. For installations of 40 Amps and below, we recommend using a NEMA cable for simple plug-and-play usage. 3 INTRODUCTION HS100 2. Product Introduction CAUTION: Avoid placing the charger near hot objects or high temperature locations and away from dangerous substances such as flammable gases and corrosive materials. 2.1.Basic Interface Digital Screen LAN Cable Inlet AC Power Input Mounting Hole Charging Cable Output 4 2.2.Basic Dimension ENCLOSURE 190 mm 7.48 330 mm 12.99 87 mm 3.42 330 mm 12.99 87 mm 3.42 Front View Left View 190 mm 7.48 Bottom View 5 HS100INTRODUCTION 2.3.Specif ications Model Name HP100-A32 HP100-A40 HP100-A48 Input AC Rating 208-240Vac Power Specif ication Max. AC Current 32A Frequency Max. Output Power 7.4kW 40A 60Hz 9.6kW 48A 11.5kW User Interface &
Control Display 2.5" Digital Screen User Authentication RFID(ISO/IEC 14443 A/B), APP
Network Interface LAN, Wi-Fi and Bluetooth Standard, 3G/4G Optional Communication Communication Protocol OCPP1.6J Optional Environment
Operating Temperature
-22 to 122 Humidity Altitude IP/IK Level 5%~95% RH, Non-condensing 6562ft(2000m), No Derating IP54/IK10 Cabinet Dimension (WDH) 7.4812.993.42(190mm330mm87mm) Mechanical Weight 11.02lbs(5kgs) Cable Length 18ft(Standard),25ft(Optional) Protection Multiple Protection OVP(Over Voltage Protection), OCP(Over Current Protection), OTP(Over Temperature Protection), UVP(Under Voltage Protection), SPD(Surge Protection Detection), Grounding Protection, SCP(Short Circuit Protection), Control Pilot Fault, Relay Welding Detection, CCID Self-test Regulation Safety Certif icate Charging Interface UL 2594, UL2231-1/-2 ETL, FCC SAE J1772 Type 1 6 HS100INTRODUCTION 2.4.Design Standards UL 2594: Electric Vehicle Supply Equipment. UL 2231-1: UL Prersonnel Protection System s for Electric Vehicle (EV) Supply Circuits:General Requirements. UL 2231: Personnel Protection Systems for Electric Vehicle (EV) Supply Circuits: Particular Requirements for Protection Devices for Use in Charging Systems. UL 2251: Plugs, Receptacles and Couplers for Electric Vehicles. UL 62: Flexible Cords and Cables. UL 991: Tests for Safety-Related Controls Employing Solid-State Devices. UL 1998: Software in Programmable Components. NFPA 70 Article 625: National Electrical Code, Electric Vehicle Charging System UL 840
(Clearance and Creepage). 7 HS100INTRODUCTION 3. Accessories Check the box to ensure you have this installation guide and these parts:
Electric Vehicle AC Charger Installation Manual For model: HS300 1 AC Charger 2 User Manual 3 Screw Cover 4 Mounting Template 5 M6 Expansion Screws*2 6 Standard RFID Cards*2 No. Product Name Quantity Description 1 2 3 AC Charger User Manual Screw Cover 4 Mounting Template 5 M6 Expansion Screws 6 Standard RFID Cards 1 1 1 1 2 2 With attached input power cable and output charging cable. PDF version available online. For covering screw. For easy drilling of 2 screws holes for AC Charger. For installing the Mounting Bracket to the wall / structure. To start/stop charger for the unit with RFID reader. 8 HS100ACCESSORIES 4. Tools for Mounting Tools required before installing the Wall-mounted charger, gather the following tools:
1 Wire stripper 2 Phillips screwdriver 3 Drill 4 Level 5 Pencil or marker 6 Adjustable wrench NOTE: The above tools are very important, get them ready prior to installation. 7 Voltmeter or digital multi-
meter (for measuring AC voltage at the installation site) 9 HS100MOUNTING MOUNTING HS100 5. Plan for Mounting WARNING: In areas with frequent thunderstorms, add surge protection at the service panel for all circuits. Ensure all power and ground connections, especially those at the breaker and bus bar, are clean and tight. CAUTION: Not recommended to be installed in coastal environments with high humidity or thick dust. STEP 1 Select the appropriate mounting location with electrical capacity. i. Ensure the owner has chosen a mounting location that allows the charging cable to reach the cars charging port while still providing slack. II. The device must be anchored on a solid wall or a stud with the dimensions: 80mm x 130mm. III. The device shall be mounted at height between 2 feet (600mm) and 4 feet (1200mm). STEP 2 Drill 2 Screw Holes with a diameter of 12mm and a depth of 57mm by using #4 mounting template. Please drill screw holes in the direction of the template arrow. 10 HS100 MOUNTING STEP 3 Nail #5 two expansion rubber sleeves into the holes and nail #5 one screw to the top expansion rubber sleeves. The distance between the cover of the screw and the wall is about 5mm. 5 mm 215 mm Insert the expansion nut STEP 4 Please unclick the shelf with slotted screwdriver, align the rear notch of charger with the holes and hang the top notch on the top screw, fit the #5 screw to the bottom hole. Cover the screw with #3 screw cover. PE L1 L2 L2 L1 PE PE PE L1 L1 L2 L2 L2 L2 L1 L1 PE PE 11 MOUNTING STEP 5 Wire the Circuit HS100 WARNING This device must be grounded. Disconnect electrical power prior to installing the charging station. Improper connection of the equipment-grounding conductor would result in a risk of electric shock. Check with a qualified electrician or service man if you are not sure whether the product is properly grounded. Do not modify the plug provided with the product if it doesnt fit the outlet, have a proper outlet installed by a qualified electrician. CAUTION Use appropriate protection when connecting to the main power distribution cable. For the safety purpose, please set circuit breaker protection in the input part of EV Charger. Please follow the instructions below:
Circuit Breaker Options Output Amperage (A) Circuit Breaker Options (A) 16A 20A 32A 40A 40A 50A 48A 60A STEP 6 Connect L1 with grid L1, L2 with grid L2 and lead the PE to the grid PE. Click back the shelf, and fix the front cover back and tighten with screws at the buttom. 12 HS100 MOUNTING PE L1 L2 L2 L1 PE PE L1 PE L1 L2 L2 L1 PE STEP 7 Overall outlook after installation 13 OPERATE HS100 6. Operate Your Device WARNING This device should be supervised when used around children. CAUTION Please use the charger properly. Do not hit or press hard on the enclosure. If the case is damaged, please contact a professional technician. To avoid any danger, please do not put any heavy objects on the charger. 6.1.Operating Steps with Plug and Charge STEP 1 Standby Mode: After the power has been turned on, you will see the sign Please Plug In on the LED screen. 14 HS100 STEP 2 Plug the Charging Connector: Please plug the charging connector into the vehicle charging inlet. OPERATE STEP 3 CHARGING: When the charging is going on, You can see "Charging, circularly voltage, currents and kWh." in the LED Screen. If the sign is on, try to plug the vehicle connector again. If the sign continues to be on, please refer to 7.2 Error and warning message. STEP 4 Charging finished: When the charging is completed, the number of total kWh will be shown. This indicates the total kWh your car has received. Please pull out the charging connector. 15
*Figures are for reference only
*Figures are for reference only OPERATE HS100 6.2.Operating Steps with RFID Card CAUTION: Avoid placing the charger near hot objects and at high temperature locations and away from dangerous substances such as flammable gases and corrosive materials. STEP 1 Standby Mode: After the power has been turned on, you will see the sign Please Plug In on the LED screen and the sign Scan QR Code or Tag Card. STEP 2 Ready to charge: Please plug the charging connector into the vehicle charging inlet. 16 HS100 STEP 3 Tap the standard RFID to start/stop charging. OPERATE
*Figures are for reference only
*Figures are for reference only
*Figures are for reference only
*Figures are for reference only STEP 4 CHARGING: When the charging is going on, You can see "Charging, circularly voltage, currents and kWh." in the LED Screen. If the sign is on, try to plug the vehicle connector again. If the sign continues to be on, please refer to 7.2 Error and warning message. STEP 5 Charging finished: When you swipe your RFID card to stop charging, the number of total kWh will be shown. This indicates the total kWh your car has received. Please pull out the charging connector. 17 7. Light Codes 7.1.The Details of Screen 7.2.Error and Warning Messages Status Off Ground RCD Abnormal Over Current Protection Over Voltage Protection Under Voltage Protection Energy Meter Fault Control Pilot Fault Over Temperature Protection Ground Fault Ground Self-Test Remark Auto Recover Auto Recover Auto Recover Auto Recover Auto Recover Contact Customer Service Auto Recover Auto Recover Auto Recover Auto Recover Screen Display 0001 0002 0004 0008 0016 0032 0128 0256 0512 1024 18 HS100WARNING HS100 WARNING 8. FCC STATEMENT This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: This device may not cause harmful interference, and this device must accept any interference received, including interference that may cause undesired operation. Caution: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. WIFI module: Contains FCC ID: 2AC7Z-ESP32WROOM32D LTE moudle: Contains FCC ID: XMR201909EC25AFX To satisfy FCC RF exposure requirements, a separation distance of 20cm or more should be maintained between the antenna of this device and persons during device operation. To ensure compliance, operations at closer than this distance is not recommended. 19 9. Warranty and Maintenance The warranty period for this charger is two years. During the warranty period for any malfunction under normal use according to the User Manual and Service Instructions (to be determined by certified maintenance technicians of sellers), the product shall be repaired free of charge. Except for the following situations, the charger shall be subject to the above warranty terms:
1. The warranty certificate cannot be provided or the contents of the warranty certificate are modified or inconsistent with the label indication of the repaired product. 2. Those who are unable to provide valid proof of purchase. 3. Those who exceed the manufacturer's specified warranty period. 4. Those who damage the product due to not following the product service instruction for use, maintenance and storage. 5. Damage or malfunction caused by external object entering. 6. Unauthorized repair, disassembly or modification. 7. Damage caused by force majeure (such as lightning, excessive voltage, earthquake, fire, flood, etc.). 8. Malfunction and damage caused by other unavoidable external factors. Malfunction and damage caused by improper use of equipment, such as water or other solutions entering into the equipment. 9. Malfunction and damage caused by the grid power supply and voltage which is not specified for use with the charger equipment. The above guarantees shall be made solely, and no other express or implied warranties shall be made (including the implied warranties of merchant ability, particular and applicable reason-ableness and adaptability, etc.) whether in the contract, civil negligence, or other aspects, the Company shall not be responsible for any special, incidental or consequential damages. 20 HS100WARNING
1 | Label and location | ID Label/Location Info | 394.26 KiB | January 19 2024 |
FC FCC ID: 2BBSV- L2 Contains FCC ID: DACTZ-ESP32WROOMS2U 904 suleqw xJvsz03606 LOZHNX al NzewoouMmzedS3-ZZOV~e Gi 903 sU Z1-As9az Cd
1 | ACB-FORM-FCC-Application-Letters-Agency-Letter | Cover Letter(s) | 224.81 KiB | January 19 2024 |
Xiamen LinkPower Tech. Co., Ltd Authority to Act as Agent Date: January 2, 2024 American Certification Body, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 To Whom It May Concern:
Intertek Testing Services Shanghai 1 is authorized to act on our behalf, until otherwise notified, for applications to American Certification Body, Inc. (ACB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. We also declare that the information provided to the FCC is true and correct to the best of our knowledge (47 CFR 2.911(d)) and we have been informed of the grantee responsibilities (47 CFR 2.909) with regard to certified equipment. Thank you, Agency Agreement Expiration Date: _____2024/12/28_____ By:
(Signature2) Carol Lee
(Print name) _ Title:
____ CEO _ On behalf of:
Xiamen LinkPower Tech. Co., Ltd
(Company Name) Telephone:
_ 18059225856 _ 1 - If a group entity is designated as the authorized agent, the letter of authorization must identify those individuals within the group who are authorized to take action on the application; or alternatively a statement must be provided indicating that as the authorized agent, any individual within the group entity is authorized to act on behalf of the applicant / grantee and take action on the application. See https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=33316 . 2 - Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead. 030122-15
1 | ACB-FORM-FCC-Application-Letters-Confidentiality-Letter | Cover Letter(s) | 266.10 KiB | January 19 2024 |
Xiamen LinkPower Tech. Co., Ltd Request for Confidentiality Date: January 2, 2024 Subject: Confidentiality Request for: _____ FCC ID:2BBSV-L2 Pursuant to FCC 47 CFR 0.457(d) and 0.459 and IC RSP-100, Section 12.4, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Short Term Short Term Short Term Short Term Short Term Short Term Short Term Short Term Short Term Permanent Permanent *1 Permanent Permanent Permanent Permanent Permanent *3 Exhibit Block Diagrams External Photos Internal Photos Operation Description/Theory of Operation Parts List & Placement/BOM Tune-Up Procedure Schematics Test Setup Photos Users Manual Xiamen LinkPower Tech. Co., Ltd has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality:
The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality:
The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of ___(specify number of days not to exceed 180)2___ days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify ACB in the event information regarding the product or the product is made available to the public before the requested period has expired. ACB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. NOTE for Industry Canada Applications:
IC currently only distinguishes Permanent Confidentiality exhibits as shown above. Short Term confidentiality is not considered applicable to IC applications. Sincerely, By:
(Signature/Title3) ____ Carol Lee
(Print name) _ 1 - The asterisked items (*) require further information to be provided to ACB before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 and the specific Document link for D01 found at:
https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. 2 - Please refer to https://acbcert.com/documents/misc-docs/Memo-Short-Term-Vs-Standard-Confidentiality.pdf 3 - Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent for complete details. letter has been provided. Letters should be placed on appropriate letterhead. 030122-15
1 | ACB-FORM-FCC-Application-Letters-Covered-List-Attestation | Attestation Statements | 273.84 KiB | January 19 2024 |
Xiamen LinkPower Tech. Co., Ltd Certification Application Attestation Statements Date: January 2, 2024 American Certification Body, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 To Whom It May Concern:
Statement for 47 CFR section 2.911(d)(5)(i) Xiamen LinkPower Tech. Co., Ltd certifies that as of the date of the application the equipment for which authorization is sought is not covered equipment1 prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not covered equipment. Additional Explanation: <N/A>
Statement for 47 CFR section 2.911(d)(5)(ii) Xiamen LinkPower Tech. Co., Ltd (the applicant) certifies that, as of the date of the filing of this application, the applicant - is / - is not identified on the Covered List as an entity producing covered equipment. Thank you, By:
(Signature2) ____ Carol Lee ___
(Print name) _ Title:
___ __ CEO _____ Company: Xiamen LinkPower Tech. Co., Ltd Telephone:
_ 18059225856 _ 1 - The Commissions Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commissions website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes covered equipment. https://www.fcc.gov/supplychain/coveredlist . 2 - Letters should be placed on appropriate letterhead. 021423-17 rev 4
1 | ACB-FORM-FCC-Application-Letters-U.S.-Agent-Letter-for-Service-of-Process | Attestation Statements | 257.72 KiB | January 19 2024 |
ELECTRON CHARGER LLC TO:
American Certification Body, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 ATTENTION: FCC Certification Section 2.911(d)(7) Information Designated U.S. Agent Company Name: ELECTRON CHARGER LLC Contact Name: Nick Metro Street Address: 71 Mid Cape Ter. Bldg 8 Cape Coral, FL 33991 City/Province/Zip: Cape Coral/33991 Telephone No: 239-790-3300 EXT:113 Email: nmetro@energyharness.com FRN #: 0034659888 This letter is to confirm that we (ELECTRON CHARGER LLC) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. U.S. Agent Signature:
Date: 2023-12-28 Signed by (Printed Name/Title): Nick Metro/ Products Engineer The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-
related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant Company name: Xiamen LinkPower Tech. Co., Ltd Grantee Code:2BBSV FRN #:0033918749 Contact Name: Carol Lee Street Address: 4th Floor, Building 3, No.29 Xinle Road, Haicang District, City/Province/Zip: Xiamen/Fujian/361026 Telephone No: 18059225856 Email: carol@elinkpower.com Applicant Signature1:
Date:2023-12-28 Signed by (Printed Name/Title): Carol Lee/CEO 1 - Letters must be placed on appropriate letterhead. The signee for the applicant must be one of the following: Applicant (grantee) contact of record in the FCCs authorization system, or authorized officers or employee of the applicant (grantee).
1 | Declaration rev1 | Cover Letter(s) | 270.88 KiB | January 19 2024 |
DECLARATION We, Xiamen LinkPower Tech. Co., Ltd declare Our companys project CSxxx-xxA/xx/xx/xx/xx/xxC/xx, HSxxx-xxA/xx/xx/xx/xx/xxC/xx Is same as Note xxx denotes Appearance, can be 100=100type, 300=300 type xx denotes Wattage, can be 16=16A, 32=32A, 40=40A, 48=48A xx denotes Functions 1, can be 4G xx denotes Functions 2, can be RF xx denotes Screen, can be 5S=5 inch screen, 7S=7 inch screen xx denotes functions 3, can be 15=ISO15118 xx denotes Outlet type, can be 18C=18ft, 25C=25ft xx denotes Colour, can be BK=Black, WT=White, BL=Blue, SR=Sliver, GR=Grey Except the appearance shape and color. The above-mentioned statements of our company are totally true. If false, we will bear corresponding liability. Company Address: 4th Floor, Building 3, No.29 Xinle Road, Haicang District, Xiamen/Fujian/361026 Telephone:
_+86 18059225856 Date December 28, 2023 Sign Title:
CEO
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2024-01-19 | 13.56 ~ 13.56 | DXX - Part 15 Low Power Communication Device Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2024-01-19
|
||||
1 | Applicant's complete, legal business name |
Xiamen LinkPower Tech. Co., Ltd
|
||||
1 | FCC Registration Number (FRN) |
0033918749
|
||||
1 | Physical Address |
4th Floor, Building 3, No.29 Xinle Road, Haicang District
|
||||
1 |
4th Floor, Building 3, No.29 Xinle Road
|
|||||
1 |
Xiamen, N/A
|
|||||
1 |
China
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
h******@acbcert.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2BBSV
|
||||
1 | Equipment Product Code |
L2
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
C**** L****
|
||||
1 | Telephone Number |
18059********
|
||||
1 | Fax Number |
18059********
|
||||
1 |
c******@elinkpower.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Intertek Testing Services Shanghai
|
||||
1 | Name |
D**** T******
|
||||
1 | Physical Address |
Building No.86, 1198 Qinzhou Road(North)
|
||||
1 |
Shanghai, 200233
|
|||||
1 |
China
|
|||||
1 | Telephone Number |
86-21********
|
||||
1 |
D******@intertek.com
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Electric Vehicle Supply Equipment | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Intertek Testing Services Shanghai
|
||||
1 | Name |
L******** X****
|
||||
1 | Telephone Number |
+86 2********
|
||||
1 |
l******@intertek.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 13.56000000 | 13.56000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC