Model: V7213 Installation Manual Thank you for choosing our products. Please read the instructions carefully before installation and keep it available for future maintenance or reference. Content Safety instructions Technical specification List of materials Technical drawing Parts identification Toilet installation Preparation Lid auto open/close Maintenance 1. Main unit care and maintenance 2. Spray nozzle maintenance and care 3. Filter maintenance Emergency troubleshooting 1. Power and water failure 2. Failure of remote control 3. Product unused for a period of time Description of the knob function Troubleshooting guide I n s t a l l a t i o n M a i n t e n a n c e O t h e r s 01 03 05 06 07 08 10 11 12 13 15 16 IMPORTANT SAFEGUARDS When using electrical products, especially when children are present, basic safety precautions should always be followed, including the following:
1. The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction. 2. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. 3. Children shall not play with the appliance. 4. Cleaning and user maintenance shall not be made by children without supervision. READ ALL INSTRUCTIONS BEFORE USING DANGER To reduce the risk of electrocution:
1. Do not use while bathing. 2. Do not place or store product where it can fall or be pulled into a tub or sink. 3. Do not place in or drop into water or other liquid. 4. Do not reach for a product that has fallen into water. Unplug immediately. 5. Do not wash the main unit or electrical plug with water or detergent. 6. Do not handle the electrical plug with wet hands. 7. Never block the outlet of the air dryer. 8. Never disassemble, repair or modify this product. 9. During installation, disassembly, repair and maintenance of the product, the power plug must be switched off and water supply be shut off. WARNING To reduce the risk of burns, electrocution, fire, or injury to persons. 1. Close supervision is necessary when this product is used by, on, or near children or individuals with disabilities. 2. Use this product only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer. 3. Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Return the product to a service center for examination and repair. 4. Keep the cord away from heated surfaces. 5. Never use while sleeping or drowsy. 6. Never drop or insert any object into any opening or hose. 7. Do not use outdoors or operate where aerosol (spray) products are being used or where oxygen is being administered. 8. Connect this product to a properly grounded outlet only. See Grounding Instructions. 9. Do not throw cigarettes and other burning materials into toilet, otherwise it might cause fire. 10. This product is an electric appliance, so it must be placed far away from water and other liquid. 11. Do not lay the product on its side or upside down during the electrical circuit. 12. It is prohibited to use other electric appliances in the same socket. 13. It is forbidden to use the power extension or unstable loose outlet. 14. Do not reuse any existing water supply hoses, otherwise it might cause leakage, fire or electrical shock. Installation should include specified components and a new water supply hose. 01 IMPORTANT SAFETY INSTRUCTIONS CAUTION Indicates that failure to follow the instruction may cause body injury or property damage. 1. Do not install or use the product in wet places as steam room etc. 2. It is recommended to use water-proof electrical outlet which should be installed in a place where is not easily to get wet. 3. This product should be used with 110V-120V, 50/60Hz electrical current only, load current is at least 15A. Power plug must be equipped with ground fault circuit interrupter or ground fault electrical leakage protector or similar high sensitive, rapid type leakage switch
(Rated sensitive current under 6mA). 4. When it thunders, it is strongly recommended to pull out the power plug. 5. Do not stand on ceramic toilet. 6. Ceramic toilet must install floor fixing bolts. 7. Do not stand on product unit, seat and lid. 8. Do not lean against the seat lid when using the product, to avoid damage. 9. This product is equipped with a soft-closing seat lid. Do not push the toilet seat closed, or damage may occur. 10. Do not use any caustic chemicals or scrubbing brush to clean this product. 11. Exposure to direct sunlight is prohibited. 12. Only use tap water or potable water, otherwise it may cause chafing. 13. Do not connect water supply to heater outlet. Make sure inlet water temperature is between 3~35/37.4~95 14. When the room temperature is under zero degree, please drain the water tank, to avoid freezing. 15. Raise room temperature to prevent the toilet from damage due to freezing. 16. When moving the product from cold or wet environment into normal room temperature, wait for 2 hours until the condensation water is fully volatilized. Doing so can prevent the product from electrical short-circuit. 17. When not using the product over three(3) days, drain the water out of the toilet and pull the electrical plug from the wall outlet. 18. Stop using the product and shut off the power when product malfunctions. Call for professional service. GROUNDING INSTRUCTIONS This product should be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded. DANGER Improper use of the grounding plug can result in a risk of electric shock. If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to either flat blade terminal. The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire. This product is factory equipped with a specific electric cord and plug to permit connection to a proper electric circuit. Make sure that the product is connected to an outlet having the same configuration as the plug. No adapter should be used with this product. Do not modify the plug provided if it will not fit the outlet, have the proper outlet installed by a qualified electrician. If the product must be reconnected for use on a different type of electric circuit, the reconnection should be made by qualified service personnel. SAVE THESE INSTRUCTIONS 02 Technical Specification Rated voltage 110V-120V, 50/60Hz Main Unit Rated power 1170-1210W Water proof IPX4 Power cord length About 2.2m Flush volume 1.27Gpf(full flush 1.6G/half flush 1.1G) Flushing mode Siphonic jet Toilet Rough-in 305mm Outlet outside diameter 100mm Drainage method S-trap Water pressure range 0.08MPa - 0.8MPa Heating mode Instant Heating power 120V/1400W Water temperature 6-level adjustment Water volume 3-level adjustment Cleaning device Cleaning mode Rear washing / Moving washing, Front washing /
Moving washing, Pulse massage Nozzle position 5-level adjustment Water pressure protector Pressure maintaining device, Automatic pressure relief device Anti-fouling device Automatic nozzle cleaning, Anti-syphon device, Anti-backflow device, Filter device Safety device Thermal fuse, Water temperature sensor, Ground protection, Thermostat, Over temperature protection, Leakage protection plug Warm air volume Over 0.2m3/min Warm air temperature 6-level adjustment Heating power 250W Drying device Safety device Thermal fuse, Leakage protection plug, Thermostat Deodorization Deodorization method Diatom Deodorization 03 Surface temperature 6-level adjustment Heating power 50W Heated seat Burn protection After 10 minutes of use, the seat temperature will automatically drop slowly to a low level Safety device Seat sensor, Temperature sensor, Thermostat, Thermal fuse, Leakage protection plug Night light assembly Intelligent, Always on, Always off User ID setting To avoid interference when used by multiple users Automatic flushing Automatic flushing after use Caring device Flushing during power failure Manual flushing after use Foot sensor function
(optional) Activate lid and seat opening (optional). Activate a half flush. Lid auto-open
(optional) With auto lid and seat opening/closing functions Sterilization (optional) Plasma sterilization Antibacterial site Seat, Nozzle Rated power:
Under the condition of ambient temperature 23/73, water static pressure 0.18MPa0.02MPa, water temperature 5/41, power toilet on, set water pressure, seat temperature, water temperature to the highest level in turn and perform one rear washing cycle. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help. WARNING: Any changes or modifications not expressly approved by the party responsible for compliance could void he user's authority to operate this equipment. 04 List of materials Main Unit Remote Controller Components Sealing Flange Installation Cardboard Installation Manual Thank you for choosing our products.Please read the instructions carefully before installation and keep it available for future maintenance or reference. Installation Manual Flange Angle Valve Braided hose Mounting accessory kit 05 Technical drawing 1092mm 707mm 528mm 415mm 405mm 425mm 1. The drawing is for reference only, and we reserve the right to modify the product appearance. 2. Product appearance is subject to change in kind. 06 Parts identification Left side Lid Knob Front washing Rear washing Dryer shield Rear washing Front washing Spray nozzle Right side Bumper Indicator light Seat Ceramic toilet Power cord Manual flush button Deodorizer Touch the sensing area with foot (optional) 07 Toilet installation 1. Installation of angle valve 3. Connect flexible hose to water inlet Draw drain outlet centerline on the floor. Install angle valve at proper position on the wall according to the dimension of toilet. Connect one end of hose to the water inlet of the toilet and tighten the connection. Mating angle valve Line Drain outlet 2. Cardboard installation Align cardboard with the centerline of drain outlet. Draw contour line according to cardboard. Inlet connector Drain outlet Flexible hose 305mm Cardboard 4. Mounting bracket installation Assemble the mounting bracket with bolts and then install them to the pre-installed flange plate on the ground and lock tight with nuts. Mounting bracket Washer Nut Bolt 08 5. Ceramic toilet installtion 6. Screw installation Install a sealing flange into drain outlet;
Install ceramic toilet on the corresponding position. Put the screw through the fixing sleeve and then install it through the holes (on both sides of the toilet ceramic) to the mounting bracket on the ground. Lock tight. Install the decorative cap on the fixing sleeve. Screw Toilet drain outlet Sealing flange Fixing sleeve Decorative cap Note:
1. Two people are required to carry the toilet. 2. Please clean up the drain outlet;
3. Please make sure ceramic toilet outlet sits perfectly on drain outlet. 7. Connect hose to angle valve Connect other end of new hose to angle valve and tighten it. 09 Preparation 1. Turn on the angle valve Check the threaded connection for leaks to ensure complete sealing. Turn the angle valve counterclockwise to the full open position.
(Note: The angle valve opens with a large torque for the first time.) Angle valve 2. Power Connection Insert the leakage protection plug into a power socket, press the reset switch, plug indicator lights up, indicating that the power is on. Note:
Press the test button prior to usage, the reset switch pops up indicating that the leakage protection function is normal. Press the TEST button (then RESET button) every month to assure proper operation. Indicator light Reset switch Current detection test button REMETTRE RESET TEST WARNING:
TEST BEFORE EACH USE 1. PLUG INTO RECEPTACLE 2. PRESS RESET BUTTON:
VISUAL INDICATOR APPEARS. 3. PRESS TEST BUTTON:
VISUAL INDICATOR DISAPPEARS. 4. PRESS RESET FOR USE. DO NOT USE IF ABOVE TEST FAILS.
* Only for models with leakage protection plug.
* Please refer to the actual product. 3. Self-inspection 1. Once power is connected, the buzzer beeps. The night light is on and the self-inspection starts. 2. The buzzer beeps again, then the self-inspection completes, and the night light is off. 3. The product is ready to use. 10 Lid auto open/close Only for the product with auto lid opening/closing function. This function is turned off by default. For the first use, please turn on this function by remote control. 1. Approaching the toilet When user enters the sensing range, the seat lid opens automatically. 2. Leaving the toilet The seat lid closes automatically 180 seconds after user leaves. 3. Standing up to urinate 1. Open the seat by remote control or hand. 2. The seat and lid close automatically 180 seconds after user leaves. If the model you purchased is with foot sensor:
1. When the seat and lid are both closed, touch the sensing area with your foot to open the lid. 2. When the lid is open and seat is closed, touch the sensing area with your foot to open the seat. 3. When the seat and lid are both open, touch the sensing area with your foot to close the seat and lid and activate a half flush. 11 Maintenance Main unit care and maintenace Spray nozzle maintenance and care 1. Shut off power supply before doing maintenance. 2. Use only a soft, damp cloth to clean. Avoid using harsh chemicals. 1. Nozzle self-cleaning When no one is seated, turn the knob clockwise. The nozzle will automatically stretch out to allow access for cleaning 2. Spray nozzle disassembly When the nozzle moves forward, the nozzle can be removed and cleaned separately. Note: While holding the wand with one hand, remove the nozzle itself by gently pulling it towards you with the other hand. 3. Use only a soft cloth or soft brush to clean Do not pull or push the wand, to avoid damage. 4. Nozzle retraction Put the nozzle back on and press knob to return the spray wand to its normal position. 3. Once cleaning is completed and all surfaces are dry, re-connect the power plug. 12 Emergency troubleshooting Filter maintenance 1. No power If poor spray perfomance occurs under normal conditions:
Press and hold the manual flushing button to flush the toilet 1.Turn off power and the angle valve 2. Unscrew angle valve nut Manual flushing button 3. Remove filter net 2. No water supply Put around 2.1Gal (8L) water into a barrel and flush the ceramic bowl. Note: Avoid water spilling from bowl. 4. Clean out the filter net under running water using a toothbrush 5. Reinstall filter net and angle valve nut 6. Turn on the angle valve and connect the power. 13 Failure of remote control Product unused for a period of time 1. Operate via knob on the main unit When the product is left unused for a long time, especially in cold weather, it is highly recommended to drain the water to prevent freezing. To discharge water 1. Unplug and cut off the electricity 2. Activate flushing, and then turn off angle valve to stop water supply. 3. Disconnect the hose from angle valve, drain the water and reconnect. 2. Battery replacement Remove the remote control from holder. Open the battery cover and replace the batteries. Put the remote control back. Note: After battery replacement, the remote control settings will be restored to the defaults. Please reset. 4. For your safety, it is recommended to put antifreeze into the remaining water in the bowl.
* Please turn on power and water supply when using again. NoteBefore water discharging, the power must be cut off!
14 Description of the knob function 1.When seated, turn the knob clockwise to start rear washing function, and turn counterclockwise to start front washing function. Rear and front washing function will automatically enter into the drying function after completion. (Note: default water pressure, water temperature, air temperature, seat temperature, wand position are intermediate.) 2. When no one is seated, turn the knob clockwise to start manual cleaning function of the nozzle. 3. During rear and front washing, turn the knob clockwise to move the spray wand forward, and counterclockwise to move the spray wand backward; Long press the knob to switch to the water pressure adjustment function. Clockwise rotation increases the water pressure, and counterclockwise rotation decreases the water pressure. (Note: During washing, long press the knob to switch between the functions of water pressure adjustment and spray wand position adjustment. 4. During drying, clockwise rotation increases air temperature and counterclockwise rotation decreases air temperature. 5. In functional mode, press the knob to stop function in progress: rear washing, front washing, drying or nozzle cleaning. In addition, press the knob to flush the toilet. 6. To enter into standby mode, press and hold the knob. 7. To enter into functional mode, press the knob.
* Default settings for all functions are intermediate when powering on. Use remote control to switch to the function level set before. Below shows the indicator light status:
Standby mode: Light off; Energy saving mode: Breathing light; Functional mode: Light always on. 15 Troubleshooting guide Problem Cause Solution Water supply hose is kinked Straighten the hose to remove the kink No water from nozzle Angle valve is off Turn on the angle valve A water failure occurred Restore the water supply Water supply hose is kinked Straighten the hose to remove the kink Angle valve is not fully turned on Turn on the angle valve fully Filter is clogged Clean the filter The water temperature is not set properly The seat temperature is not set properly Adjust the water temperature Adjust the seat temperature In standby mode The dryer temperature is not set properly In standby mode or energy saving mode Power off Switch to functional mode and wait for 3+ minutes Adjust the dryer temperature Switch to functional mode to use dry function Push back the spray wand gently and put power on Get stuck by impurities Remove the impurities Power off Turn on the power User is not within the sensing area of the seat The positive and negative direction of the batteries is incorrect Adjust position on seat to activate the sensor Reload the batteries Low battery Replace new batteries User is not within the sensing area of the seat Deodorization function continues after user leaves. Adjust position on seat to activate the sensor It is normal for the deodorizing function to continue operating after user leaves, for complete odor removal. If the problem cannot be resolved as per above solutions, please disconnect the power and contact service providers. If the power leakage protection switch always trips, it means that the product is leaking. Please disconnect the power and contact service providers. Poor water spraying Low water temperature Low seat temperature Low dryer temperature Dryer not blowing Spray wand cannot retract Spray wand cannot stretch out Remote control cannot display Malfunction of deodorization Caution 16 The picture of product may not be entirely consistent with actual appearance and color because of product improvements, please in kind prevail. ASVFA72130006A-1.1